COMMITTEE DRAFT FOR VOTE (CDV) PROJET DE COMIT POUR VOTE (CDV) IEC 61169-24/Ed 2.0
Secretariat / Secrtariat

SC46F

France
Closing date for voting (Voting mandatory for P-members) Date de clture du vote (Vote obligatoire pour les membres (P))

Date of circulation Date de diffusion

2008-02-22

2008-07-25
Supersedes document Remplace le document

Also of interest to the following committees Intresse galement les comits suivants

IEC SC46A, IEC TC100, ISO IEC JTC1 SC25


Functions concerned Fonctions concernes Safety Scurit EMC CEM

46F/63/CD and 69/CC

Environment Environnement

Quality assurance Assurance qualit

CE DOCUMENT EST TOUJOURS L'TUDE ET SUSCEPTIBLE DE MODIFICATION. IL NE PEUT SERVIR DE RFRENCE. LES RCIPIENDAIRES DU PRSENT DOCUMENT SONT INVITS PRSENTER, AVEC LEURS OBSERVATIONS, LA NOTIFICATION DES DROITS DE PROPRIT DONT ILS AURAIENT VENTUELLEMENT CONNAISSANCE ET FOURNIR UNE DOCUMENTATION EXPLICATIVE.

THIS DOCUMENT IS STILL UNDER STUDY AND SUBJECT TO CHANGE. IT SHOULD NOT BE USED FOR REFERENCE PURPOSES. RECIPIENTS OF THIS DOCUMENT ARE INVITED TO SUBMIT, W ITH THEIR COMMENTS, NOTIFICATION OF ANY RELEVANT PATENT RIGHTS OF WHICH THEY ARE AW ARE AND TO PROVIDE SUPPORTING DOCUMENTATION.

Title : IEC 61169-24: Radio-frequency connectors Part 24: Sectional specification Radio frequency coaxial connectors with screw coupling typically for use in 75 ohm cable networks (type F)

Introductory note : The French version will be circulated later.

ATTENTION VOTE PARALLLE CEI CENELEC Lattention des Comits nationaux de la CEI, membres du CENELEC, est attire sur le fait que ce projet de comit pour vote (CDV) de Norme internationale est soumis au vote parallle. Un bulletin de vote spar pour le vote CENELEC leur sera envoy par le Secrtariat Central du CENELEC.

ATTENTION IEC CENELEC PARALLEL VOTING The attention of IEC National Committees, members of CENELEC, is drawn to the fact that this Committee Draft for Vote (CDV) for an International Standard is submitted for parallel voting. A separate form for CENELEC voting will be sent to them by the CENELEC Central Secretariat.

Copyright 2008 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions. You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without permission in writing from IEC.

61169-24/Ed.2 IEC:200X

CONTENTS
1 2 3 Scope ...............................................................................................................................5 Normative references .......................................................................................................5 Interface Dimensions ........................................................................................................5 3.1 Dimensions .............................................................................................................5 3.1.1 Connector F Type female Socket (indoor) Physical Dimensions ................6 3.1.2 Connector F Type Male plug (indoor) Physical Dimensions .......................6 3.2 Mechanical gauges..................................................................................................8 3.2.1 Mating Socket Centre Conductor Acceptance Diameter Test .......................8 3.2.2 Mating Port Centre Conductor Acceptance Electrical Test ...........................9 3.2.3 Reference Plane Electrical Contact .............................................................9 Quality assessment procedures ........................................................................................9 4.1 4.2 4.3 4.4 General ...................................................................................................................9 Ratings and characteristics .....................................................................................9 Environmental characteristics for outdoor sockets (see Annex A) .......................... 10 Test Schedule and Inspection requirements .......................................................... 10 4.4.1 Acceptance tests ....................................................................................... 10 4.4.2 Periodic tests ............................................................................................ 11 4.5 Procedures............................................................................................................ 13 4.5.1 Quality conformance inspection ................................................................. 13 4.5.2 Qualification approval and its maintenance ................................................ 13 Instructions for preparation of detail specifications ......................................................... 13 General ................................................................................................................. 13 Identification of the Detail specification ................................................................. 13 Identification of the component .............................................................................. 14 Performance.......................................................................................................... 14 Marking, ordering information and related matters ................................................. 14 Selection of tests, test conditions and severities.................................................... 14 Blank detail specification pro-forma for type F connector ....................................... 15 Recommended Outdoor F Type Socket / Plug Physical Dimensions ..................... 20 Outdoor F Type Female Socket........................................................................... 20 Outdoor F Type Male Plug .................................................................................. 22

5.1 5.2 5.3 5.4 5.5 5.6 5.7 Annex A A.1 A.2

61169-24/Ed.2 IEC:200X

INTERNATIONAL ELECTROTECHNICAL COMMISSION ___________ RADIO-FREQUENCY CONNECTORS Part 24: Sectional specification Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable networks (type F) FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as IEC Publication(s)). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 61169-24 has been prepared by subcommittee 46F: RF and microwave passive components, of IEC technical committee 46: Cables, wires, waveguides, RF connectors and accessories for communication and signalling. This second edition differs from the first edition in that all drawings have been reworked and improved to allow frequency extension up to 3 GHz. The text of this standard is based on the following documents:
FDIS XX/XX/FDIS Report on voting XX/XX/RVD

Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

61169-24/Ed.2 IEC:200X

The committee has decided that the contents of this publication will remain unchanged until the maintenance result date 1) indicated on the IEC web site under "http://webstore.iec.ch" in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended.

1) The National Committees are requested to note that for this publication the maintenance result date is 2011

61169-24/Ed.2 IEC:200X

RADIO-FREQUENCY CONNECTORS Part 24: Sectional specification Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable networks (type F)
1 Scope

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with screw coupling, typically for use in 75 ohm cable networks (type F). It describes the interface dimensions with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all DS relating to type F connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.

Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61169-1, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods

3
3.1

Interface Dimensions
Dimensions

Millimetres are original dimensions. All undimensioned pictorial configurations are for reference purposes only.

61169-24/Ed.2 IEC:200X

3.1.1

Connector F Type female Socket (indoor) Physical Dimensions

5 C

H A

3/832 UNEF2A

D E G

0.05

Reference Plane Figure 1. Connector F Type female Socket (indoor)

Table 1.
DESCRIPTION

Connector F Type female Socket (indoor)


DIM mm inches NOTES

REF. PLANE OPENING INNER DIAMETER REF. PLANE OUTER DIAMETER POSITIVE CONTACT POINT DEPTH PORT MINIMUM FULL THREAD LENGTH MINIMUM CENTER CONTACT DEPTH CENTER CONDUCTOR GUIDE INNER DIAMETER

A B C D E F

MIN 3,90 7,50 -7,50 9,00 1,2

MAX 7,4 8,50 4,70 --1,5

MIN 0.154 0.295 -0.295 0.354 0.047

MAX 0.291 0.335 0.185 --0.059

3 6 5 7

NOTES: 1 2 3 5 6 7

DRAWING NOT TO SCALE. INTERPRET DRAWING IN ACCORDANCE WITH ASME Y14.5M-1994. DIELECTRIC SHALL NOT PROTRUDE BEYOND REF PLANE. THREAD RELIEF NOT TO EXCEED TWO FULL THREADS. RECOMMENDED MATING MALE CENTER CONDUCTOR DIAMETER: 0.025 in. (0.64 mm) MIN. TO 0.042 in. (1.07 mm) MAX. CENTER CONTACT GEOMETRY OPTIONAL

3.1.2

Connector F Type Male plug (indoor) Physical Dimensions

61169-24/Ed.2 IEC:200X

Figure 2. Connector F Type Male plug (indoor))

Table 2.
DESCRIPTION

Connector F Type Male plug (indoor)


DIM mm inches NOTES

MIN INNER CONDUCTOR LENGTH LENGTH OF NUT MAXIMUM ENVELOPE DIMENSION INNER CONDUCTOR DIAMETER SEALING SURFACE DIAMETER FOR SEAL RING REFERENCE DIAMETER PLANE OPENING INNER A B C D E F 6,35 4,00 -0,64 10,41 --

MAX 8,63 7,29 16,61 1,13 11,04 5,84

MIN .250 0.157 -0.025 0.410 --

MAX .340 0.287 .654 0.044 0.435 0.230 3 3

NOTES:

1 2 3 5

DRAWING NOT TO SCALE. INTERPRET DRAWING IN ACCORDANCE WITH ASME Y14.5M-1994. DIELECTRIC SHALL NOT PROTRUDE BEYOND REF PLANE THE MATING OF THE F FEMALE SOCKET TO THE REFERENCE PLANE SHALL NOT BE IMPEDED

61169-24/Ed.2 IEC:200X
6

8
IF USED, SHALL MEET ALL PERFORMANCE

GASKET SEAL OPTIONAL, REQUIREMENTS

3.2

Mechanical gauges

Millimetres are original dimensions. All undimensioned pictorial configurations are for reference purposes only. 3.2.1 Mating Socket Centre Conductor Acceptance Diameter Test In order to verify that the centre female contact of the socket does not suffer from mechanical deformation when mated with the full range of indicated inner conductor diameters, a test has been devised. This test measures the force required to insert and withdraw a selection of precision Test Pins into and out of the F female socket under test.
Note:- Retention of the inner conductor shall be by means of pressure exerted by the conductive centre female contact, not by means of any other non-conductive insert within the reference plane opening.

The test apparatus should be so designed as to enable accurate alignment of the F female socket under test with the precision Test Pin. The apparatus should hold either the socket or the Test Pin in a fixed position, and the moving part of the apparatus should be fitted with an instrument capable of measuring the insertion and withdrawal force. Using the test sequence shown below, the insertion and withdrawal force shall be measured and recorded in Newton

Figure 3. Gauge for the centre socket conductor

Table 3.
Test Sequence Test Pin Diameter 1 st Test

Test sequence for the centre socket conductor


2 nd Test 0,850mm 3 rd Test 1,136mm 4 th Test 0,635mm 5 th Test 1,136mm 6 th Test 0,635mm

0,635mm

The insertion force required to insert the Test Pin into the socket centre female contact shall not exceed 20 Newton under all circumstances.

61169-24/Ed.2 IEC:200X

The withdrawal force required to withdraw the Test Pin from the socket centre female contact shall be a minimum of 0,3 Newton under all circumstances. 3.2.2 Mating Port Centre Conductor Acceptance Electrical Test After completion of the mechanical tests described in clause 3.2.1, the centre conductor contact resistance, when re-mated with a male F plug whose centre conductor diameter is 0,635mm, shall not exceed 10m with an applied test ampere rate of 1A. 3.2.3 Reference Plane Electrical Contact The electrical contact shall be made by the mating of the reference plane face of the F female socket with the mating face of the F male plug and not by the threads alone.

4
4.1

Quality assessment procedures


General

The following subclauses provide recommended ratings, performance and test conditions to be considered when writing a detail specification (DS). They also provide an appropriate schedule of tests with minimum levels of conformance inspection. 4.2 Ratings and characteristics

The RF connectors defined in this standard are designed for use with a variety of flexible and semi-rigid coaxial cables and in microwave integrated circuits and similar uncabled applications. Table 4.
Ratings and characteristics

Rating and characteristic


Value Remarks including any deviations from standard test methods

IEC 61169-1 Subclause

Electrical Nominal impedance Shall meet the requirements of 9.2.1.1 of IEC 61169-1 when terminating a Z c = 75 cable 5MHz to 1 GHz 5MHz to 2 GHz 5MHz to 3 GHz Reflection factor - straight styles - right angle styles - solder bucket and PCB mounting style - Insertion loss 49.2.14. Min. 30dB up to 1Ghz min. 25dB up to 2 GHz min. 20dB up to 3 GHz See DS Under consideration 0.1dB max up to 1GHz. 0.2dB max at 2GHz. 0.3dB max at 3 GHz. 9.2.3 < 5 m < 10 m 9.2.3 < 2,5 m < 5 m .9.2.5 > 1 G > 1 M See DS For most applications. For some Satellite applications For some Head end applications.

Frequency range

Centre contact resistance - initial - after conditioning Outer conductor continuity - initial - after conditioning Insulation resistance - initial - after conditioning

61169-24/Ed.2 IEC:200X
Proof voltage at sea level + # Screening effectiveness Discharge test (Corona) Mechanical Gauge retention force (resilient contacts) Contact captivation axial force torque Engagement and separation Coupling torque friction coupling proof Mechanical tests on cable cable pulling # cable torsion # Tensile strength of coupling mechanism Bending moment Environmental Vibration Climatic sequence Sealing Salt mist Endurance Mechanical High temperature NOTES 0,19.57.10 9.60 9.3.3 9.4.2 9.4.5 9.4.6 9.3.8 9.3.10 9.3.11 9.3.12 9.3.6 9.3.4 9.3.5 .9.2.6 .9.2.8 .9.2.9

10
750 V a s 90 dB na 86-106 kPa Z t < 3,2 m

See 3.2 of IEC 61169-1 20 N Max. na

Captivated contacts only Screw coupling connectors

0,066 Nm max. 0,46 Nm to 0,69 Nm 3,3 Nm 120 N 0,1 Nm 300 N 2 Nm

To overcome friction of a coupling nut

Relative to reference plane

98 m/s 10 Hz to 500 Hz 40/70/21 1 cm 3 /h max 48 h

10 g acceleration

100-110 kPa pressure

1000 cycles 1000 h

These values apply to basic connectors. They depend on the cable used. Relevant values are given in the DS. + Voltage values are r.m.s. values at 50-60 Hz, unless otherwise specified. # Cables used with these connectors may have values of lower performance than those given in this table.

4.3

Environmental characteristics for outdoor sockets (see Annex A)

When the F type male plug and the F type female socket are mated, the physical attributes shall be protected and sealed to prevent moisture ingress and as a minimum shall meet IPX8 rating. Any F type (outdoor) male plug ore female socket shall be resistant to corrosion and shall meet EN 60068-2-52 Salt Mist Cyclic Test. 4.4 Test Schedule and Inspection requirements

4.4.1 Acceptance tests


NOTE For details of symbols, abbreviations and procedures, see 4.5.2.

61169-24/Ed.2 IEC:200X

11

Table 5.
Test method IEC 61169-1 Subclause Group A1 Visual examination Group B1 Outline dimensions Mechanical compatibility Engagement and separation Gauge retention (resilient contact) Sealing, non-hermetic Sealing, hermetic Voltage proof Solderability piece parts Insulation resistance 9.1.3.1 9.1.3.3 9.3.6 9.3.4 9.4.5.1 9.4.5.2 9.2.6 9.3.2.1.1 9.2.5 a a a ia ia ia a ia a 9.1.2 a

Acceptance tests
Assessment level H (lower) Test Require d IL AQL % Perio d

Assessment level M (higher) Test Require d IL AQL % Perio d

II

1,0

S3

1,5

S4 II S4 II II II S4 S4 S4

0,4 1,0 0,40 1,0 0,65 0,015 0,40 0,40 0,40 lot by Lot

a a a Ia ia ia a ia a

S3 S3 S3 S3 S3 S3 II S3 S3

4,0 1,5 1,5 1,5 1,0 0,025 4,0 4,0 4,0 lot by Lot

4.4.2 Periodic tests There are no group C tests for levels H and M.
NOTE For details of symbols, abbreviations and procedures, see 4.5.2.

Table 6.
Test method IEC 611691 subclause

Rating and characteristic (cont 1)


Assessment level H (lower)
Period Test required Number of specimen s Permitted failures per group Period

Assessment level M (higher)


Test require d Number of specimen s Permitted failures per group

Group D1 (d) Solderability connector assemblies Resistance to soldering heat Mechanical tests on cable fixing - cable rotation (nutation) - cable pulling - cable bending - cable torsion 9.3.7.2 9.3.8 9.3.9 9.3.10 ia ia ia ia 9.3.2.1.1 ia

3 years ia

3 years

9.3.2.1.2

ia

ia

ia ia ia ia

61169-24/Ed.2 IEC:200X Table 7.


Test method IEC 611691 subclause

12 Rating and characteristic (cont 2)


Assessment level H (lower)
Period Test required Number of specimen s Permitted failures per group Period

Assessment level M (higher)


Test require d Number of specimen s Permitted failures per group

Group D2 (d) Contact resistance, outer conductor and screen continuity centre conductor continuity Vibration Damp heat, steady state Group D3 (d) Dimensions piece-parts and materials Group D4 (d) Mechanical endurance High temperature endurance Sulphur dioxide Group D5 (d) Reflection factor Screening effectiveness Water immersion Group D6 (d) Contact captivation Rapid change of temperature Climatic sequence Group D7 (d) Resistance to solvents and contaminating fluids 9.7 ia 9.3.5 9.4.4 9.4.2 a na a 9.2.1 9.2.8 9.2.7 a a ia 9.5 9.6 a a 9.1.3.2 a 9.2.3 a

3 years a

3 years

9.3.3 9.4.3

a a 1* 1 3 years a a 1* 1 3 years

3 years a a

3 years

9.4.8

na 6 1 3 years

na 3 a a ia 6 1 3 years a na a 1 3 years ia 1# 3 years 3 1 3 years 1 3 years

61169-24/Ed.2 IEC:200X 4.5 Procedures

13

4.5.1 Quality conformance inspection This shall consist of test groups A1 and B1 on a lot-by-lot basis. 4.5.2 Qualification approval and its maintenance This shall consist of three consecutive lots passing test groups A1 and B1 followed by selection of specimens from the lots as appropriate. These specimens shall successfully pass the specified periodic D tests. Details of symbols, abbreviations and procedures:
a ia na IL = = = = = suggested as applicable test suggested (if technically applicable) not applicable Inspection Level Acceptable Quality Level one set of piece-parts each style and variant, unless using common piece parts

AQL =
*

# = for Qualification Approval (QA) a total of two failures only permitted for level H and 1 failure only for level M from groups D1 to D7 (d) = = Group D7 number of pairs for each solvent destructive tests specimens shall not be returned to stock

5
5.1

Instructions for preparation of detail specifications


General

Detail specifications (DS) writers shall use the appropriate BDS pro-forma. The following pages comprise the pro-forma BDS dedicated for use with 75 type F connectors. As such, it will already have entered on it information relating to a) the basic specification number applicable to all the detail specifications covering connector styles of the type covered by the sectional specification; b) the connector series designation. The specification writer should enter the details relating to the connector style/variant(s) to be covered as indicated. The numbers in brackets on the BDS pro-forma correspond to the following indications which shall be given. 5.2 (1) (2) (3) (4) Identification of the Detail specification The name of the National Standards Organization (NSO) under whose authority the DS is published and, if applicable, the organization from whom the DS is available. The relevant mark of conformity and the number allotted to the DS by the relevant national or international organization authorizing the DS The number and issue number of the IEC/IECQ generic or sectional specification as relevant; also national reference if different. If different from the IEC/IECQ number, any national number of the DS, date of issue and any further information required by the national system, together with any amendment numbers.

61169-24/Ed.2 IEC:200X

14

5.3

Identification of the component Style: Attachment: The style designation of the connector including type of fixing and sealing, if applicable. By deletion of the inapplicable options of cable/wire: given for centre and outer conductors.

(5) Enter the following details:

Special features and markings: As applicable. (6) Enter details of assessment level and the climatic category. (7) A reproduction of the outline drawing and details of the panel piercing, if applicable. It shall provide the maximum envelope dimensions, also the position of the reference plane and, in the case of a fixed connector, the position of the mounting plane(s) relative to the front face of the connector. Any maximum panel thickness limitations for fixed connectors shall be stated. (8) Particulars of all variants covered by the DS. As appropriate, the information shall include: cable types (or sizes) applicable to each variant; alternative plated or protective finishes;

details of alternative mounting flanges having either tapped or plain mounting holes; details of alternative solder spills or solder buckets including, when applicable, those for use with Microwave Integrated Circuit (MIC) components. 5.4 Performance

(9) Performance data listing the most important characteristics of the connector taking into account the recommended values in 4.2.of this specification. Deviations from the minimum requirements shall be clearly indicated. Non-applicable parameters shall be marked na. 5.5 Marking, ordering information and related matters

(10) Insert marking and ordering information as appropriate, together with details of related documents and any invoked structural similarity. 5.6 Selection of tests, test conditions and severities

(11) na shall be used to indicate non-applicable tests. All tests marked a by the detail specification writer shall be mandatory. When using the normal procedure with a dedicated BDS, the letter a for applicable shall be entered in the Test required column against each of the tests indicated as being mandatory in the test schedule as in 4.3 of this specification. Any additional tests required at the discretion of the specification writer shall also be indicated by an a. The specification writer shall also indicate, when necessary, details of deviations from the standard test methods and test conditions, including any relevant deviations given in the test schedule of the sectional specification. The qualification approval and conformance inspection shall be such that the National Supervising Inspectorate (NSI) shall be satisfied that they are appropriate and in line with those for other connectors within the system providing a reasonably comparable service.

61169-24/Ed.2 IEC:200X 5.7

15

Blank detail specification pro-forma for type F connector

The following pages contain the complete BDS pro-forma.

(1)

Page 1 of 10

QC 222401
ELECTRONIC COMPONENT OF ASSESSED QUALITY IN ACCORDANCE WITH GENERIC SPECIFICATION QC 220000 SECTIONAL SPECIFICATION QC 222400 NATIONAL REFERENCE

(4) ISSUE
................ ........................

(5) Detail specification for Radio frequency coaxial connector of assessed quality
Style:....................................................... Method of cable/wire+ attachment

type F

Special features and markings centre conductor solder/crimp+ outer conductor solder/clamp/crimp + + delete as appropriate Characteristic impedance 75 Climatic category..../.../.../

(6) Assessment level......... (7) Outline and maximum dimensions (8) Variants Variant No. 01....... ............. ............. ............. ............. ............. ............. ............. Description of variant ............. ............. ............. ............. ............. ............. ............. ............. .............

Panel piercing and mounting details

60096 IEC ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. ............. .............

Information about manufacturers who have components qualified to this detail specification is available in the current QC 001005 Qualified Product List.

61169-24/Ed.2 IEC:200X

16

(9) Performance (including limiting conditions of use)


IEC 61169-1 (QC 220000) Subclause Remarks including any deviations from standard test methods

Ratings and characteristics Electrical Nominal impedance Frequency range Reflection factor Variant No. Designation 01....... ........... Centre contact resistance Centre conductor continuity 01....... ........... ............ ..............

Value

75 0-3 GHz 9.2.1 ........... ........... ............ 9.2.3 9.2.3 ...........m ............m .............m .............m .............m .............m ...........m ............m ............G ............G ..............kV ..............kV ..............kV ..............kV ...............V ...............V ...............V ...............V ...............V ...............V ...............V ...............V ...............V ...............V ...............V ...............V 9.2.8 ........... ........... Initial After conditioning Resistance change due to conditioning Measurement frequency range

Outer contact continuity Insulation resistance + Proof voltage at sea level 01....... ........... ............ .............. 01....... ........... ............ .............. 01....... ........... ............ .............. 01....... ........... ............ .............. 01....... ........... ............ ..............

9.2.3 9.2.5 9.2.6

Initial After conditioning Initial After conditioning 86-106 kPa

+ Proof voltage at 4,4 kPa

.........kPa (if not 4,4 kPa)

+ Environment test voltage at sea level

86-106 kPa

Environment test voltage at 4,4 kPa

.........kPa (if not 4,4 kPa)

Screening effectiveness

dB at....GHz Z t ............

ADDITIONAL ELECTRICAL CHARACTERISTICS

+ Voltage values are r.m.s. values at 50-60 Hz, unless otherwise specified.

61169-24/Ed.2 IEC:200X

17

Ratings and characteristics Mechanical Soldering - bit size Gauge retention resilient contacts - inner contact - outer contact Centre contact captivation - axial force - permitted displacement each direction Engagement and separation - axial force Effectiveness of cable fixing against - cable rotation 01....... ........... ............ .............. 01....... ........... ............ .............. 01....... ........... ............ .............. 01....... ........... ............ ..............

IEC 61169-1 (QC 220000) Subclause

Value

Remarks including any deviations from standard test methods

9.3.2.1.1 ............... 9.3.4.3

...............

9.3.5 ................N ................mm 9.3.6 .............N (eng) .............N (sep)

9.3.7.2

Rotations ................. .................. ................. ..........N ........... ............ .............. ..........Cycles ........... ............ .............. ..........Nm ........... ............ .............. ...............Nm ..........m/s ......to....Hz Relative to reference plane (......g n acceleration) Length of cable mass ................. .......... ................. .......... ................. ..........

- cable pulling

9.3.8

- cable bending

9.3.9

- cable torsion

9.3.10

Bending moment Vibration ADDITIONAL MECHANICAL CHARACTERISTICS

9.3.12 9.3.3

61169-24/Ed.2 IEC:200X

18

Ratings and characteristics Environmental Climatic category Sealing non-hermetically sealed connectors Sealing hermetically sealed connectors Water immersion ADDITIONAL ENVIRONMENTAL CHARACTERISTICS

IEC 61169-1 (QC 220000) Subclause

Value

Remarks including any deviations from standard test methods

...../....../...... 9.4.5.1 9.4.5.2 9.2.7 ......cm 3 /h 10 5 bar/cm 3 /h 100-110 kPa pressure differential 100-110 kPa pressure differential

ENDURANCE Mechanical High temperature ADDITIONAL ENDURANCE CHARACTERISTICS CHEMICAL CONTAMINATION Resistance to solvents and contaminating fluids to be used. Applicable fluids. Sulphur dioxide 9.4.8 days 9.7 .............. ............... ................. 9.5 9.6 ...operations ..........h at..........C

61169-24/Ed.2 IEC:200X (10) Supplementary information

19

Marking of the component: in accordance with 11.1 of IEC 61169-1 (QC 220000) in the following order of preference: 1) Manufacturer code: 2) Manufacturing date code: 3) Component identification: ........................... year/week Variant No./ Identification Designation .................................. .................................. .................................. .................................. .................................. .................................. .................................. ...................................

- Marking and contents of package: in accordance with 11.2 of IEC 61169-1 1) 2) 3) 4) Information prescribed in 11.1 of IEC 61169-1 detailed above Nominal characteristic impedance ..................75 ........................... Assessment level code letter ................................................... Any additional marking required ................................................... IECQC 222401......./Variant code.. ................................................... ................................................... .....................................................

Ordering information 1) Number of the detail specification 2) Assessment level code letter 3) Body finish (if more than one listed) 4) Any additional information or special requirements

- Related documents (if not included in IEC 61169-1 or sectional specification): ............................................................................................................ ............................................................................................................. - Structural similarity in accordance with 10.2.2 IEC 61169-1
NOTE Relevant information on a basic style should be entered as variant 01.

___________

61169-24/Ed.2 IEC:200X

20

Annex A Recommended Outdoor F Type Socket / Plug Physical Dimensions


A.1 Outdoor F Type Female Socket

Figure A.1 Outdoor Female F Socket


DESCRIPTION DIM MIN REF PLANE OPENING INNER DIAMETER REF PLANE OUTER DIAMETER POSITIVE CONTACT POINT DEPTH FULL THREAD DEPTH MINIMUM CENTER CONDUCTOR CLEARANCE CENTER CONDUCTOR GUIDE INNER DIAMETER PORT LENGTH SEALING SURFACE DIAMETER FOR SEAL RING BULKHEAD DIAMETER A B C D E F G H J 3.90 7.50 -8.26 9.00 1.20 12.32 9.35 10.80 mm MAX 6.10 8.00 4.70 8.89 -1.50 13.08 9.65 -inches MIN 0.154 0.295 -0.325 0.354 0.047 0.485 0.368 0.425 MAX 0.240 0.315 0.185 0.350 -0.059 0.515 0.380 -4 6 5 7,8 3 NOTES

Table A.1 Outdoor Female F Socket Dimensions

NOTES 1 DRAWING NOT TO SCALE.

61169-24/Ed.2 IEC:200X
2 3 4 5 6

21

INTERPRET DRAWING IN ACCORDANCE WITH ASME Y14.5M-1994. NO MATERIAL SHALL PROTRUDE BEYOND REF. PLANE IF CAST FEATURE, NO PARTING LINES PERMITTED. THREAD RELIEF NOT TO EXCEED TWO FULL THREADS. DIMENSION TO POINT OF POSITIVE CONTACT OF MALE CENTER CONDUCTOR. RECOMMENDED MATING MALE CENTER CONDUCTOR DIAMETER: 0.025 in. (0.64mm) MIN. / 0.042 in. (1.07 mm) MAX.

7 8 9

MINIMUM CLEARANCE REQUIRED FOR MAXIMUM LENGTH MALE CENTER CONDUCTOR. CENTER CONTACT GEOMETRY OPTIONAL MINIMUM BULKHEAD STOP. GEOMETRY OPTIONAL (EXAMPLE: HEX, CYLINDRICAL, FLAT SURFACE AREA).

61169-24/Ed.2 IEC:200X

22

A.2

Outdoor F Type Male Plug


3/8-32 UNEF-2B 5 J X 45 C

D E G

F 4 H B A
1 0.100 REFERENCE PLANE 2

Figure A.2 Outdoor F Type Male Plug


DESCRIPTION DIM MIN INNER CONDUCTOR LENGTH. LENGTH OF NUT MAXIMUM ENVELOPE DIMENSION INNER CONDUCTOR DIAMETER SEALING DIAMETER FOR SEAL RING REFERENCE PLANE INNER DIAMETER REFERENCE PLANE OUTER DIAMETER SEALING SURFACE LENGTH CHAMFER BREAK A B C D E F G H J 6.35 4.29 -0.64 10.50 -7.11 1.78 0.127 mm MAX 8.63 6.10 16.61 1.07 11.00 5.84 -4.45 0.381 inches MIN .250 .169 -0.025 0.413 -0.310 0.079 0.005 MAX .340 .240 .654 0.42 0.433 0.230 -0.175 0.015 4 5 3 NOTES

Table A.2 Outdoor F Type Male Plug Dimensions

61169-24/Ed.2 IEC:200X
NOTES 1 2 3 4 5

23

DIELECTRIC MUST NOT PROTRUDE BEYOND REF. PLANE THE MATING OF THE F FEMALE SOCKET TO THE REFERENCE PLANE SHOULD NOT BE IMPEDED. MINIMUM ONE THREAD LEAD-IN. DRAWING NOT TO SCALE. CABLE INNER CONDUCTOR OR INTERGRAL PIN