PRODUCT DATA SHEET StorMaxx Ptec Storage Tanks

Technical Specifications
Capacity (gal) Dia. w/o insulation (in) Dia. w/ insulation (in) Insulation (in)* Height w/ insulation (in) Tilted height (in) Heat area top/bottom (ft2) Water content WT top/bottom (gal) Volume flow WT top/bottom (gal/hour) Pressure loss WT top/bottom (psi) Performance index top/bottom according to DIN 4708 Continuous output top/bottom according to DIN 4708 (50F/180F/115F) (gal/hour) Max. T/max. P TW (F/psi) Max. T/max. P HZG (F/psi)
*

StorMaxx Ptec 502HX


50 19.7 23.6 48.5 53.9 6.5/8.6 1/1.3 185/317 0.44/1 1.23/3.6 108/188

StorMaxx Ptec 802HX


80 19.7 23.6 2 66.8 70.9 8.6/12.9 1.3/2 264/423 .5/1.3 1.8/8 160/256

StorMaxx Ptec 1052HX


105 23.6 27.6 65.4 70.9 10.8/16.2 1.7/2.5 317/528 .65/1.74 2.1/11 190/312

StorMaxx Ptec 1302HX


130 25.6 29.5 70.2 77.6 12.9/19.4 2/3 370/634 .8/3.6 2.5/14 219/370

200 / 145 320/363 G1 G G G 1 DN 110 Sensor sleeve, inside diameter 9 mm M8 thermometer optional

Cold-/Hotwater, ext. thread (KW/WW) (in) Circulation, ext. thread (Z) (in) Heat exchangers, all ext. threaded (VL/RL) (in) Electric heating, int. thread (E-HZG) (in) Nominal width of the inspection flange (RFL) Connections for sensors/regulators (F1, F2) Thermometer connection
*

Insulation is not detachable. In order to achieve the performance NL given Here, the boiler output needs to be higher than the stated continuous output. The working medium of the heat exchanger is water in liquid state only.

Upright storage tank made of steel S235JRG2 with 2 large surface bare-tube heat exchangers Enameling in accordance with DIN 4753 Part 3 on the inside, primer applied to the outside Magnesium protection anode of 1 provided for completion of the cathodic corrosion protection in accordance with DIN 4753 Part 6 Sensor tube included As standard fitted with a 1 sleeve for re-fitting of an electric heating element Inspection opening 180 x 110 x LK 150 All external threads are flat sealing CFC-free hard PU-foam insulation with a thickness of 50 mm and a casing of foil-clad, colored synthetic material in accordance with DIN 4753 Part 8, RAL colours 9006; 9010; 2002; 5015 Compressive strength 10 bar

SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com

2010 SunMaxx Solar, Inc. Specifications subject to change without notice.

PRODUCT DATA SHEET, continued StorMaxx Ptec Storage Tanks

7 11

5 8 6 5 10 3 9 8 4 2

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.

Hot Water Outlet Cold Water Inlet Solar Supply Solar Return Auxiliary Coil Port Recirculation Port Magnesium Anode Temp Sensor Well Cleaning Flange Electric Heating Element* Thermometer*

*Optional components

SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com
2010 SunMaxx Solar, Inc. Specifications subject to change without notice.