1)The surge impedance of 50 miles long underground cable is 50

. For a 25 miles length, it will be

1. 2. 3. 4.

25 50 100 none of the above

2)If the fault current is 2000A, the relay setting is 50% and the CT ratio is 400/5, then the plug setting multiplier would be

1. 2. 3. 4.

0.1 400 5 none of these

3)if the time of operation of a relay for unity TMS is 10 seconds, then the time of operation for 0.5 TMS will be

1. 2. 3. 4.
4)

20 seconds 5 seconds 10 seconds none of these If the phase angle of the voltage coil of a directional relay is 500, then the maximum torque angle of the relay

is

1. 2.

2300 800

The stability of arc in vacuum depends upon 1. 2. 3. 4.

the contact material only the contact material and its vapour pressure the circuit parameters only the combination of (2) and (3)

Bottom of Form

6)Carrier current protection scheme is normally used for

1. HV transmission lines only 2. HV cables only 3. HV transmission and cables 4. none of these
7)For rural electrification in a country like India with complex networks, it is preferable to use

1. 2. 3. 4.

air break C.B

oil C.B

vacuum C.B

M.O.C.B

8)The : R ratio for 220 kV line as that compared to 400 kV line is

1. greater 2. smaller

3. equal 4. it could be anything

If the inertia constant H of a machine of 200 MVA is 2 pv, then its value corresponding to 400 MVA will be

1. 4 p.v 2. 2 p.v 3. 1 p.v 4. 0.5 p.v The insulation resistance of a cable of length 10 km is 1 M, its resistance for 50 km length will be

1. 1 M 2. 5 M 3. 0.2 M 4. none of these The leakage resistance of a 50 km long cable is 1 M. For a 100 km long cable it will be

1. 1 M 2. 2 M 3. 0.66 M 4. none of these The coefficient of reflection for current for an open ended line is

1. 1.0 2. 1.0 3. 0.5

4. none of these The P.V. synchronous impedance of a machine is 2 pv, its SCR is

1. 0.2 2. 1 3. 0.5 4. none The reflection coefficient of a short circuited line for voltage is

1. 1 2. 1 3. 0.5 4. none The Buchholz relay prevents a transformer from

1. all types of internal faults 2. a turn to turn fault 3. winding to winding fault 4. none of these What is the Buchholz relay?

1. Oil temperature actuated relay 2. Oil actuated relay 3. Gas actuated relay 4. Current actuated relay What is the Buchholz relay?

1. Oil temperature actuated relay 2. Oil actuated relay 3. Gas actuated relay 4. Current actuated relay Consider the supply to the Konkan region in which the Corona loss at 50Hz supply is 1000/phase/km. If the supply frequency is now made 25 Hz, then the Corona loss will be

1. 1 kW/phase/km 2. 0.5 kW/phase/km 3. 0.667 kW/phase/km 4. none of these Consider the power supply to Mumbai city. A 50 Hz, 4 pole alternator has the following properties:

Rating = 20mvA and 13.2 kV

Inertia constant = 4000 m-sec/kvA(i) the rotor at synchronous speed.

Estimate the kinetic energy stored in

1. 80 KJ 2. 80 MJ 3. 40 MJ 4. 20 MJ Estimate the synchronous speed.

1. 1500 rpm

2. 1000 rpm 3. 2000 rpm 4. None of the above If the inductance and capacitance of a system are 1 H and 0.01 MF respectively and the instantaneous value of current interrupted is 10A, then the resistance across the breaker contact is

1. 10 K 2. 5 K 3. 20 K 4. none of the above The voltage across the breaker contacts will be

1. 100 kV 2. 50 kV 3. 200 kV 4. none of the above


Consider a 3-P line operating at 50Hz. The figure below shows the arrangement of the copper conductors, which have a diameter of 8mm. Estimate the mutual GMD of the conductor.

1. 2.015 m 2. 1.43 m

3. 0.496 m 4. none of these


Consider a 3-P line operating at 50Hz. The figure below shows the arrangement of the copper conductors, which have a diameter of 8mm. The self GMD of the conductor will be

1. 0.003115 metre 2. 0.0124 metre 3. 48.67 metres 4. data insufficient


The current in the primary and secondary coils of the given transformer is

1. 0.1 Amp 2. 10 Amp 3. 10 Amp 4. none of these

The primary current is

1. 5 Amp 2. 20 Amp 3. 10 Amp 4. none of these