Corinex AV200 Powerline Ethernet Wall Mount

0 e 20 lin t AV wer oun Po ll M Wa

Quick Start Guide

Copyright

This document, as well as the software described in it, is furnished under license and may be used or copied only in accordance with the terms of the license. The content of this document is furnished for informational use only, it is subject to change without notice, and it does not represent a commitment on the part of Corinex Communications Corp. Corinex Communications Corp. assumes no responsibility or liability for any errors or inaccuracies that may appear in this document. It is our policy to enhance our products as new technologies, hardware components, software and firmware become available; therefore, the information contained in this document is subject to change without notice. Some features, functions, and operations described in this document may not be included and sold in certain countries due to government regulations or marketing policies. The use of the product or its features described in this document may be restricted or regulated by law in some countries. If you are unsure which restrictions or regulations apply, you should consult your regional Corinex office or the authorized reseller. Published by: Corinex Communications Corp. # 670 - 789 West Pender Street Vancouver, B.C. V6C 1H2 CANADA Tel: +1 - 604 - 692 0520 Fax: +1 - 604 - 6940061 Corinex is a registered trademark of Corinex Communications Corp. Apple, MAC OS X are either registered trademarks or trademarks of Apple Computer, Inc. in the U.S.A. and/or other countries. Microsoft, MS-DOS, MS, Windows are either registered trademarks or trademarks of Microsoft Corporation in the U.S.A. and/or other countries. All products or company names mentioned herein may be the trademarks of their respective owners. Copyright (c) 2001-2006 by Corinex Communications Corp. NOTE: This equipment has been tested and found to comply with the limits for a Class B information technology equipment. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference, the end user is advised to take adequate measures.

2006-04-28 ver.2.0

Corinex AV200 Powerline Ethernet Wall Mount

Quick Start Guide

Quick Start Guide


Thank you for choosing the Corinex AV200 Powerline Ethernet Wall Mount. Please follow the steps below, to set up your adapter and the initial configuration. 1. 2. 3. Plug the Wall Mount directly into a wall outlet, not a power strip. It will power up automatically. Connect the computer to the adapter, using a straight-forward Ethernet cable which came with the product. Change the IP address of your computer to 10.10.1.1, and the network mask to 255.255.0.0. For more information on how to set the IP address on your system, please see the User Guide, which can be found on the enclosed CD. Open a web browser (eg. Internet Explorer) and type the following address : http://10.10.1.69. This will open the configuration pages for your Corinex AV200 Powerline Ethernet Wall Mount.

4. 5.

Corinex AV200 Powerline Ethernet Wall Mount

Quick Start Guide

On the authentication screen, enter paterna in the password field and click OK.

Corinex AV200 Powerline Ethernet Wall Mount

Quick Start Guide

6.

You should now see the main page of the configuration interface.

Please click on Advanced Settings in the main menu. On the next page, click on Network Settings in the submenu.

Corinex AV200 Powerline Ethernet Wall Mount

Quick Start Guide

7.

In the Network Settings section of the configuration page, change the IP address of your Corinex AV200 Powerline Ethernet Wall Mount.

5
Note : Please make sure that each adapter in your network has a unique IP address. 8. 9. After entering a new IP Address, click OK. Please wait until the configuration page reloads. Navigate to the Tools section in the submenu. Click on Hardware Reset.

Corinex AV200 Powerline Ethernet Wall Mount

Quick Start Guide

The wall mount adapter will reboot with the new IP Address.

Corinex AV200 Powerline Ethernet Wall Mount

Quick Start Guide

Please change the IP address for each and every adapter in your network. For example, if you have 3 adapters in your network, you can use the following configuration: Adapter no. 1 2 3 IP Address 10.10.1.1 10.10.1.2 10.10.1.3

The CD included with your Corinex AV200 Powerline Ethernet Wall Mount features software for optimizing network performance on Microsoft Windows operating systems, for use with the Corinex AV200 Powerline Ethernet Wall Mount. Follow the steps below if you wish to optimize your system. 1. Insert the enclosed CD in your CD-ROM drive if you havent already done so. 2. Navigate to the Scripts folder on the CD and execute the appropriate script for your operating system. a) b) c) For Windows 98/ME, please execute the file tcpwin_w98.reg. For Windows 2000/XP please execute the file tcpwin_xp.reg , For a Linux PC with kernel version 2.4 or higher, open the console and execute the command ./tcpwin.sh 512 after logging in as a root user.

After executing the script, please reboot your computer. Configuration of your Corinex AV200 Powerline Ethernet Wall Mount is now complete. For more information about the setup, please read the User Guide, which is also included on the CD and thanks again for choosing Corinex!