Product Data Sheet

Architectural Wall Panel


APPLICATION KS600/900/1000 Architectural Wall Panel system is secret fix and can be laid horizontally or vertically. Suitable for all building applications except where there are low temperature internal conditions. KS600/900/1000 MR - Micro

KS600/900/1000 EB Euro Box

KS600/900/1000 FL/FL-S Flat/Stucco

KS600/900/1000 MM - Mini Micro

KS600/900/1000 CX - Convex

KS600/900/1000 WV - Wave

KS600/900/1000 PL - Plank

KS1000 TL - Tram Line

Page 1 of 4

August 2009

Product Data Sheet


Architectural Wall Panel
DIMENSIONS & WEIGHT Core Thickness (mm) Weight kg/m2 0.63/0.4 steel PRODUCT TOLERANCES Length Width Thickness End Squareness Flatness (per metre) 5mm 2mm 2mm 3mm 2mm 45 10.9 +5mm +2mm +2mm +3mm +2mm 60 11.5 70 11.9 80 12.3 100 13.1 120 13.9 140 14.6

AVAILABLE LENGTHS Standard lengths 1.8 to 12metres. Panel lengths up to 17metres are available. Panels less than 1.8m long can be supplied and are subject to an extra charge. These panels cannot be end lapped. MATERIALS STEEL Substrate Kingspan Spectrum: Z275 hot-dip zinc coated steel to BS EN10147: 1992. Kingspan XL Forte: S220GD+ZA hot-dip zinc alloy coated steel to BS EN10214: 1992. Standard external sheet thickness 0.63mm, standard internal sheet thickness 0.4mm. Coatings - External Sheet Kingspan Spectrum: nominal 60 microns thick. Colour Standard. Kingspan XL Forte: pre-painted colour coated system applied to the weather side of the panel. Designed to achieve high levels of durability and colour stability, is highly resistant to damage in transit and on-site. Reverse side of sheet coated with a light grey polyester coating. Coatings - Internal Liner Bright White Polyester: coating developed for use for the internal lining of insulated panels. Standard colour is bright white with an easily cleaned surface. Kingspan CleanSafe: hygienic coating developed for use where the liner is exposed to foodstuffs and is regularly cleaned. Colour white. Kingspan AquaSafe: coating for internal high humidity environments. Colour white. Reverse side of sheet coated with a light grey polyester coating. INSULATION CORE Polyisocyanurate (PIR): ECOsafe, zero Ozone Depletion Potential (zero ODP) and low Global Warming Potential (GWP). LPCB insurer approved FIREsafe certified product. ENVIRONMENTAL Kingspan Architectural Wall Panels have a Green Guide A plus rating as per the BRE Global The Green Guide To Specification, Green Guide 2008 ratings. SEALS Factory Applied Side Joint Seal All side joints have a factory-applied seal fitted into the groove to automatically seal the joint between panels. PERFORMANCE Thermal Insulation Kingspan Architectural Wall Panels have a Thermal Transmittance (U value), calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Section 6 (Scotland), of: Core Thickness (mm) U value (W/m2K) 45 0.52 60 0.35 70 0.30 80 0.27 100 0.21 120 0.18 140 0.15

Page 2 of 4

August 2009

Product Data Sheet


Architectural Wall Panel
Fire The steel outer and inner facings have Class 1 surface spread of flame to BS476 - 7: 1987, and are Class 0, as defined by Building Regulations. Acoustics All Kingspan Architectural Wall Panels have a single figure weighted sound reduction Rw = 24dB. Sound Reduction Index (SRI) Frequency Hz 63 125 SRI dB 20 15 250 17 500 23 1k 18 2k 25 4k 40 8k 46

GUARANTEES & WARRANTIES Kingspan will provide external coating and product warranties and guarantees on an individual project basis. PACKING Standard Packing Kingspan wall panels are stacked horizontally (with weather sheet upward). Removable hot melt adhesive is laid between each panel. The top, bottom, sides and ends are protected with polystyrene and timber packing and the entire pack is wrapped in polythene. The number of panels in each pack depends on panel thickness. Sea Freight Fully timber crated packs are available on projects requiring delivery by sea freight shipping, at additional cost. Alternatively, steel containers can be used. Special loading charges apply. DELIVERY All deliveries (unless indicated otherwise) are by road transport to project site. Off loading is the responsibility of the client. SITE INSTALLATION PROCEDURE Site assembly instructions are available from the Kingspan Field Service Department.

Page 3 of 4

August 2009

Product Data Sheet


Architectural Wall Panel
STRUCTURAL Unfactored Load/Span Table (use calculated design wind-load values unfactored)

Single Span Condition


Panel Load 2.0 2.71 2.32 4.05 3.63 4.83 4.43 5.39 4.98 5.39 5.36 2.2 2.19 1.83 3.35 2.95 4.12 3.60 4.85 4.03 4.85 4.78

Uniformly distributed loads kN/m


Span L in metres
2.4 1.86 1.53 2.89 2.52 3.58 3.09 4.26 3.46 4.48 4.10 2.6 1.53 1.22 2.42 2.08 3.03 2.58 3.64 2.88 4.10 3.42 2.8 1.31 1.03 2.11 1.79 2.66 2.26 3.21 2.53 3.83 3.00 3.0 1.09 0.83 1.79 1.49 2.28 1.94 2.78 2.17 3.56 2.57 3.2 0.94 0.69 1.57 1.29 2.01 1.70 2.47 1.93 3.35 2.29

Thickness Type mm Pressure 45 Suction 60 Pressure Suction 70 Pressure Suction 80 Pressure Suction 100 Pressure Suction

3.4 0.79 0.54 1.35 1.08 1.74 1.46 2.15 1.69 2.96 2.00

3.6 0.69 0.44 1.19 0.94 1.55 1.28 1.92 1.52 2.67 1.80

3.8 0.59 0.33 1.03 0.79 1.35 1.10 1.69 1.35 2.37 1.60

4.0 0.52 0.27 0.91 0.69 1.21 0.97 1.52 1.23 2.15 1.46

Double Span Condition 2 Uniformly distributed loads kN/m Panel Load


Thickness Type mm Pressure 45 Suction 60 Pressure Suction 70 Pressure Suction 80 Pressure Suction 100 Pressure Suction

Span L in metres
2.0 3.45 3.05 4.64 3.93 5.05 4.49 5.39 4.98 5.39 5.36 2.2 2.95 2.45 4.11 3.15 4.54 3.60 4.85 4.03 4.85 4.78 2.4 2.61 2.10 3.67 2.71 4.19 3.09 4.48 3.46 4.48 4.10 2.6 2.27 1.75 3.22 2.26 3.84 2.58 4.10 2.88 4.10 3.42 2.8 1.95 1.54 2.76 1.98 3.30 2.26 3.67 2.53 3.83 3.00 3.0 1.63 1.32 2.29 1.69 2.75 1.94 3.23 2.17 3.56 2.57 3.2 1.42 1.17 1.98 1.51 2.36 1.73 2.77 1.93 3.28 2.29 3.4 1.20 1.02 1.66 1.32 1.97 1.51 2.30 1.69 2.99 2.00 3.6 1.06 0.92 1.46 1.19 1.73 1.36 2.01 1.52 2.60 1.80 3.8 0.92 0.82 1.26 1.06 1.48 1.21 1.71 1.35 2.20 1.60 4.0 0.83 0.75 1.13 0.96 1.32 1.10 1.52 1.23 1.94 1.46

Notes: 1.

Values have been calculated using the limit state method described in the European Recommendations for the Design of Sandwich Panels (ECCS document No.115 2001), taking imposed loads, temperature and creep into account. For each value individual and combined load cases with appropriate load factors and temperatures have been Considered. These are detailed under Structural Performance in Building Design Section of the Kingspan Design and Construction Guide. The table is for dark coloured panels. The following deflection limits have been used: Pressure Loading L/100 Suction Loading L/100 For intermediate values linear interpolation may be used.

6. The actual wind suction load resisted by the panel is dependant upon the number of fasteners used and the material of the rail. The fastener calculation should be carried out in Accordance with the appropriate standard, a minimum of two fasteners per support is required. TM For further advice please contact Kingspan envirocare Technical Services. 7. The allowable steelwork tolerance between bearing planes of adjacent cladding rails is 5mm 8. Load span tables for spans outside of those shown are TM available from the Kingspan envirocare Technical Services.

2.

3. 4.

5.

Page 4 of 4

August 2009