DAIKIN Code AO A1 A3 A5 A6 A7 A9 AF AJ C3 C4 C5 C7 C9 CC CA CJ CE E0 E1 E3 E4 E5 E5 E6 E6 E7 E8 E9 EA F3 F6 FC H3 H4 H6 H7 H8 H9 J1 J2 J3 J4 J5 J6 J7 J8 J9 JA JC JH L0 L3 L4 L5 L6 L7 L8

MALFUNCTION CODES Place Description Indoor Error of external protection device Indoor PCB defect Indoor Malfunction of drain Level control system Indoor Freeze-up prevention Indoor Fan motor lock, Overload Indoor Malfunction of swing motor flap Indoor Malfunction of EEV Indoor Drain level above limit (clogging) Indoor Malfunction of capacity set device Indoor Malfunction of drain thermistor Indoor Malfunction of liquid pipe thermistor Indoor Malfunction of gas pipe thermistor Indoor Lower louvre limit switch/motor Indoor Malfunction of air thermistor Indoor Malfunction of moisture sensor Indoor Malfunction of discharge air thermistor Indoor Malfunction of remote control thermistor Indoor Malfunction of radiant heat sensor Outdoor Activation of outdoor safety device Outdoor PCB defect Outdoor Activation of high pressure switch Outdoor Activation of low pressure switch Outdoor Activation of compressor over heat protection Outdoor Compressor motor lock Outdoor Compressor start up error Outdoor Standard compressor lock/overcurrent Outdoor Fan motor lock, Overload Outdoor Inverter input overcurrent Outdoor Malfunction of EEV Outdoor Four way valve defective. Outdoor Abnormal discharge pipe temperature Outdoor Refrigerant overcharged Outdoor Low pressure drop. Outdoor High pressure switch defect Outdoor Low pressure switch defect Outdoor Compressor motor position detection sensor error Outdoor Fan motor position detection sensor error Outdoor Current transformer error Outdoor Malfunction of air thermistor Outdoor Malfunction of pressure sensor Outdoor Current sensor malfunction Outdoor Malfunction of discharge pipe thermistor Outdoor Low pressure saturation thermistor Outdoor Malfunction of suction pipe thermistor Outdoor Malfunction of heat exchanger thermistor Outdoor Malfunction of heat exchanger liquid thermistor Outdoor Malfunction of liquid pipe thermistor Outdoor Malfunction of gas pipe thermistor Outdoor Malfunction of discharge pipe pressure sensor Outdoor Malfunction of suction pipe pressure sensor Outdoor Malfunction of oil temperature sensor Outdoor Malfunction of inverter Outdoor Electronic component box overheat Outdoor Inverter cooling defect Outdoor Comp motor ground fault, Short circuit Outdoor Compressor motor grounding/short circuit Outdoor Total input overcurrent Outdoor Comp overload, Motor disconnected

L9 Outdoor Compressor lock LA Outdoor Power unit malfunction LC Outdoor Transmission between inverter & outdoor P1 Outdoor Inverter over ripple P3 Outdoor Thermistor abnormality P4 Outdoor Power unit humidity sensor malfunction PJ Outdoor Failure of capacity set resistor U0 System Shortage of refrigerant or EEV failure U1 System Negative phase, Open phase U2 System Power supply insufficient U3 System Wiring check operation not executed U3 System Mismatch of indoor and outdoor units (Split only) U4 System Transmission between indoor units U5 System Transmission to remote controller U6 System Malfunction transmission outdoor to BP unit U7 System Transmission between outdoor units U7 Outdoor Malfunction between outdoor boards(RMX/RX RK) U8 System Transmission between master & slave R/C U9 System Transmission error between indoor to outdoor UA System Excessive number of fancoils UC System Address duplication of central controllers UE System Transmission error between indoor & central UF System Refrigeration system not set/wiring - piping UF System Terminals 1 and 3 crossed (Split/Skyair) UH System System error, Refrigeration system set up M1 System PCB defect M8 System Transmission error between central controllers MA System Improper combination of optional controllers MC System Address duplication, Improper setting 64 VAM Indoor unit air thermistor error 65 VAM Outside air thermistor error 68 VAM 6A VAM Damper system alarm 6A VAM Damper system and thermistor error 6F VAM Malfunction of remote controller 6H VAM Malfunction of door switch or connector 94 VAM Internal transmission error Grey fault codes, system still runs, but check ASAP

You might also like