Instruction for installation of the (VSD) compressor running outside the standard operating limits. This guideline is an addendum to the established instruction manuals and installation proposals.

Content Standard installation................................................................................................................... 3 1.1. See installation proposal in the instruction manual.................................................... 3 1.2. Nominal working conditions for the workplace compressor. .................................... 3 2. Storage of the compressor :................................................................................................ 4 2.1. Storage of the compressor before the 1st start (ex factory). ....................................... 4 2.2. Storage of the compressor after the 1 st start. .............................................................. 4 2.2.1. The compressor has run and is not installed. No wires connected. .................... 4 2.2.2. The compressor is connected to the supply network. ......................................... 4 3. Working conditions ............................................................................................................ 5 3.1. Outdoor use: ............................................................................................................... 5 3.2. Will the environment of the compressor exceed ambient conditions? ....................... 5 3.2.1. Maximum ambient conditions ............................................................................ 5 3.2.2. Minimum ambient conditions ............................................................................. 5 3.3. Will the environment of the compressor exceed maximum relative humidity? ......... 6 4. Limits for start up (power will be put on the compressor)................................................. 6 4.1. Will the environment of the compressor exceed minimum ambient condition? ........ 6 4.2. Will the environment of the compressor exceed maximum relative humidity? ......... 6 5. High altitude installation .................................................................................................... 6

-2-

Installation proposal

9820 4534 00 Ed 01

Standard installation
1.1. See installation proposal in the instruction manual

Ex. Installation proposal for the GA 75-90VSD 2005

1.2. Nominal working conditions for the workplace compressor.


Limits for operation (unit is installed and power is on) Ex. The GA 30-90+ range: Indoor use only according the installation proposal Minimum working pressure: 4 bar (e) Maximum ambient temperature: 46 C Minimum ambient temperature: 0 C Maximum relative humidity: 95% for VSDs only

When the compressor will be installed in an environment that exceeds one of the installation limits/ limits of operation special precaution are needed.

-3-

Installation proposal

9820 4534 00 Ed 01

2. Storage of the compressor :


2.1. Storage of the compressor before the 1st start (ex factory).

Please check that the package is not broken. Storage limits of the compressor: Outdoor From -10C up to 60C ambient conditions

2.2.

Storage of the compressor after the 1 st start.

2.2.1. The compressor has run and is not installed. No wires connected.
Follow the instruction manual Taking out of operation. Please check that no condensation/water can enter the compressor. Storage limits of the compressor: Outdoor From -10C up to 60C ambient conditions

2.2.2. The compressor is connected to the supply network.


Please follow the guidelines of the instruction manual. Start up the compressor 2 or 3 times a week and let the compressor run warm. After stopping the compressor press the test button of each electronic water drain until all water has been drained. When the compressor can not start-up 2 or 3 times, foresee precautions in paragraph 2.2.1.

-4-

Installation proposal

9820 4534 00 Ed 01

3. Working conditions
3.1. Outdoor use:

Will the compressor be installed under a roof, please check that no water can enter the compressor. When there is no roof above the compressor or water can enter the compressor => install the rain protection. Depending on the location, protections should be available for: Direct sun radiation. Entrance of flying snow. The electrical cubicle has a UL certification type 1; local modifications might be needed for other approval types.

3.2. Will the environment of the compressor exceed ambient conditions?


3.2.1. Maximum ambient conditions

When the ambient conditions of the compressor in the compressor room will exceed the maximum condition: Check if it is possible to improve the cooling of the compressor room. If this is not possible install the HAV variant of the compressor. Maximum ambient conditions for HAV variants check the working limits of the compressor range.

3.2.2. Minimum ambient conditions


When the ambient conditions of the compressor in the compressor room will exceed the minimum condition: Check if the compressor room temperature can be heated. If this is not possible install the freeze protection of the compressor. For the design limits of the freeze protection of the compressor check the working limits: Ex. Freeze protection of the GA + version: Order freeze protection. Our freeze protection is foreseen for minimum ambient of -10C. If the environment will be lower then -10C special precautions will be needed.

-5-

Installation proposal

9820 4534 00 Ed 01

3.3. Will the environment of the compressor exceed maximum relative humidity?
When the ambient condition exceeds the limits install the anti condensation protection option.

4. Limits for start up (power will be put on the compressor)

4.1. Will the environment of the compressor exceed minimum ambient condition?
Check if the freeze protection is installed. If so follow the start-up procedure: 1. Please put power on the freeze protection and wait for 1 hour with the door open. 2. After minimum 1 hour power your compressor and wait for 1 hour. 3. Then you can start-up your compressor.

4.2. Will the environment of the compressor exceed maximum relative humidity?
Check if the anti condensation option is installed? If so follow the start-up procedure: 1. Open the electrical cubicle door and after minimum 1 hour power-on your compressor. 2. Put power on the anti-condensation protection and wait for 1 hour. 3. The compressor can be started.

5. High altitude installation


Please check instruction 9820 4165 00