C o n t e n t s

Wo r k l a m p s L E D 5-21

Lamp Inserts 39-45

Wo r k l a m p s H I D 22-28

Auxillary 46-52

Halogen 29-31

Emergency 53-63

Marine 32-38

Backup Alarm 64-67

T e c h n i c a l Standards

JW Speaker meets various regulations for lighting products for our customers on a global market. The following are some of standards and regulations which Speakers meets from design to development and to the end product.

ASAE Standards
Agricultural Society of American Engineers regulations for agricultural equipment.

SAE Standards
SAE International (SAE), formerly the Society of Automotive Engineers, is a professional organization for mobility engineering professionals in the aerospace, automotive, and commercial vehicle industries. The Society is a standards development organization for the engineering of powered vehicles of all kinds, including cars, trucks, boats, aircraft, and others. The SAE standards is mainly used in the US and Canada and does not recognise ECE approvals.

ECE Standards
UNECE United Nations Economic Commission for Europe (UNECE) Transport Division has been providing secretariat services to the World Forum for Harmonization of Vehicle Regulations for more than 50 years. The World Forum has incorporated into its regulatory framework the technological innovations of vehicles to make them safer and more environmentally sound. Most countries, even if not formally participating in the 1958 agreement, recognise the ECE Regulations and either mirror the ECE Regulations content in their own national requirements (Australian Design Rules:- ADRs), or permit the use and importation of ECE-approved vehicles, or both.

UNITED NATIONS

UL Recognised
Underwriters Laboratories Inc. (UL) is an independent product safety certification organization. Based in Northbrook, Illinois, UL develops standards and test procedures for products, materials, components, assemblies, tools and equipment, chiefly dealing with product safety. UL also evaluates and certifies the efficiency of a companys business processes through its management system registration programs. Additionally, UL analyzes drinking and other clean water samples through its drinking water laboratory in South Bend, Indiana and evaluates products for environmental sustainability through its subsidiary, UL Environment. UL is one of several companies approved for such testing by the U.S. federal agency OSHA. OSHA maintains a list of approved testing laboratories, known as Nationally Recognized Testing Laboratories.

CE Recognised
The CE marking (also known as CE mark) is a mandatory conformity mark on many products placed on the single market in the European Economic Area (EEA). The CE marking certifies that a product has met EU consumer safety, health or environmental requirements.

T e c h n i c a l IP Ratings

IP (Ingress Protection) Ratings


The IP Code outlines a system of classification for the protection of electrical enclosures against the intrusion of foreign bodies ( i.e., tools, fingers, dust, etc. ) and moisture. The system of classification was specified by the International Electrotechnical Commission and is officially designated as IEC 60529. The rating is specified by the letters IP followed by two digits i.e. IP25, IP68, etc. IP ratings International Protection ratings are covered in Australian Standard AS1939. - This system uses a two digit code to specify the degree of particle and water resistance of a luminaire. - The first digit indicates the degree of protection of the interior from the ingress of solid foreign objects. - The second digit indicates the degree of protection of the interior from the ingress of water.

First Number - Degree of ingress protection


The first number of the IP code indicates the degree of protection against contact with moving parts and the degree that the equipment is protected against solid foreign bodies intruding into an enclosure.

0123456-

No protection provided. Protection against entry of objects larger than 50 square mm. Protection against entry of objects larger than 12 square mm. Protection against entry of objects larger than 2.5 square mm. Protection against entry of objects larger than 1.0 square mm. Protection against entry of dust in sufficient quantity to prevent satisfactory operation. Complete protection against entry of dust.

First Number example

Complete protection against entry of dust

IP65

Second number - Degree of moisture protection


The second number indicates the degree of protection for the equipment inside the enclosure against the harmful entry of various forms of moisture (e.g. dripping, spraying, submersion, etc.)

0 - No protection provided. 1 - Protection against drops of water falling vertically. 2 - Protection against drops of water falling vertically when the luminaire is
tilted up to 15 degrees from its normal position.

Second Number example

345678-

Protection from entry of water spray from angle of up to 60 degrees from vertical. Protection from entry of water splashes or spray from any direction. Protection from a low pressure jet of water in any direction. Protection against heavy seas or a strong jet of water in any direction. Protection against immersion up to 1 metre. Protection against submersion over 1 metre.

Protection from a low pressure jet of water in any direction.

IP65

For example IP65 means: Complete protection against entry of dust & protection from a low pressure jet of water in any direction.

T e c h n i c a l LED Info
LED Forward Lighting
Material Losses - light is scattered as it passes through material.

LED lamp output values (Lumens) can vary dramatically depending on which values are being quoted. The following information may assist selecting the right product for the right application.

RAW vs Effective Light Output


There are inherent losses associated with any lamp (LED, Halogen, HID or Incandescent). The main losses are related to 3 items: Thermal Losses, Optical Losses and Assembly variation.

Thermal Losses:
The greatest challenge is Thermal management of LEDs. LED Manufacturers typically measure the light produced by their LEDs after 25 milliseconds (ms). That is equivalent to a flash bulb. It gives a lumen number that is the absolute maximum value. However, LEDs produce less light as they get hotter. LEDs generate a tremendous amount of power in a relatively smaller area.
Light - is lost as it travels across boundaries (reflection).

As the LEDs are powered for longer and longer periods of time, they typically get hotter and hotter depending on the thermal management system. Its not unusual for LEDs get to over 100 C. For vehicle applications, most specifications require that the lamp be measured at 10 minutes and 30 minutes to make sure that the LEDs temperature has stabilized. This will result in the LED producing 10 - 20% less light than its advertised value.

Optical & Assembly Losses:


As light travels though an object (Lens), it loses intensity depending on the clarity of the lens material. This is due to inherent losses internal to the material and to losses at the boundary of the part as the light travels from air through the lens and back to air. These losses are present whether the light source is an LED or bulb. The losses associated with the lens material and optics again can vary from 10 - 20%. There are also losses associated with assembly and manufacturing variation. The LEDs output varies as the assembly tolerances may diminish the
Raw Lumens 8 x 100 Lumens / LED = 800 Lumens

overall performance from the lamp from theoretically LED maximums. Simply adding the expected values of the LED light sources together will never result in a lamp that shines that amount of light on the ground.

Thermal Losses 10 - 20% Optical Losses 10 - 20%


Assembly Losses -10%

RAW
The RAW lumen output is calculated by simply taking the number of LEDs In a lamp and multiplying by the LED rated output. Example: 8 LEDs rated at 100 lumen per watt 8 x 100 = 800 Lumen

Effective
The effective lumen output is calculated by taking the RAW lumen value and subtracting the Thermal, Optical and assembly losses. Example: RAW Lumens = 800 Less - Thermal, Optical & Assembly Losses = 40% Effective Lumens = 480 Lumens
4

LED
LED
4400 Series 6700 Series 830 Series 831 Series 700 Series 701 Series 735 Series 736 Series 7150 Series 781 Series 783 Series 524 Series 522 Series 523 Series 708 Series

5-21
6 7 8 9 10 11 12 13 14-15 16 17 28 19 20 21

L E D 4400 Series
Function: Size: Lens: Housing: Worklamp 66mm round Polycarbonate Reinforced Nylon

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: Standards: Connector:
70

100 Lumens

Effective: 75 Lumens 12V DC 0.25 Amps @ 12 volts Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Mounting: Wiring:
66

34

95

39

Effective Lumens Isolux Charts Flood


40m

0m

40m 0m 50m 150m

Part No. 0543081 0543251 0543261

Pattern Flood Flood Flood

Lens Polycarbonate Polycarbonate Polycarbonate

Voltage 12V 12V 12V

Light Output White Amber Red

Description Complete worklamp Complete worklamp Complete worklamp

L E D 6700 Series
Function: Size: Lens: Housing: Worklamp 120mm round Glass/Polycarbonate Rubber

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw:
120 83

690 Lumens

Effective: 280 Lumens 12-48V DC 1.2 Amps @ 12 volts 0.63 Amps @ 24 volts 0.42 Amps @ 36V 0.315 Amps @ 48 volts Standards:
120 146

Sealed to IP67 UL Recognised Universal mount Pre-wired with 300mm cable

Mounting: Wiring:

Effective Lumens Isolux Charts Flood


30m 30m

Trap

0m

0m

30m

30m

0m

50m

100m

150m

0m

50m

100m

150m

Part No. 1402781 1402761 1402791 1402861 3153501 3152961 3153491

Pattern Flood Trap Flood Flood Flood Flood Trap

Lens Glass Glass Polycarbonate Glass Glass Polycarbonate Glass

Voltage 12-48V 12-48V 12-48V 12-48V 12-48V 12-48V 12-48V

Light Output White White White White White White White

Description Complete worklamp Complete worklamp Complete worklamp Complete worklamp-Marine PAR36 LED sealed beam 114mm PAR36 LED sealed beam 114mm PAR36 LED sealed beam 114mm
7

L E D 830 Series
Function: Size: Lens: Housing: Worklamp 97 x 97mm Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: 840 Lumens Effective: 450 Lumens 12-48V DC 2.0 Amps @ 12V 0.79 Amps @ 24V 0.55 Amps @ 36V 0.5 Amps @ 48V
97 126 297

Standards: Connector: Mounting: Wiring:

Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

100

41

Effective Lumens Isolux Charts Flood


30m 30m

Trap

0m

0m

30m

30m

0m

50m

100m

150m

0m

50m

100m

150m

Part No. 0543241 0543781

Pattern Flood Trap

Lens Polycarbonate Polycarbonate

Voltage 12-48V 12-48V

Light Output White White

Description Complete worklamp Complete worklamp

L E D 831 Series
Function: Size: Lens: Housing: Worklamp 97 x 97mm Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: 1980 Lumens Effective: 950 Lumens 12 or 24V DC 1.2 Amps @ 12.6 volts 0.63 Amps @ 24 volts 0.42 Amps @ 36V 0.315 Amps @ 48 volts
97 126 297

Standards: Connector: Mounting: Wiring:

Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

100

41

Effective Lumens Isolux Charts Flood


30m 30m

Trap

0m

0m

30m

30m

0m

50m

100m

150m

0m

50m

100m

150m

Part No. 0543601 0543611 0543621 0543631

Pattern Flood Trap Flood Trap

Lens Polycarbonate Polycarbonate Polycarbonate Polycarbonate

Voltage 12V 12V 24V 24V

Light Output White White White White

Description Complete worklamp Complete worklamp Complete worklamp Complete worklamp

L E D 700 Series
Function: Size: Lens: Housing: Worklamp 144 x 95mm oval Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw:
144 80

776 Lumens

Effective: 400 Lumens 12-48V DC 2.0 Amps @ 12V 1.0 Amps @ 24V 0.66 Amps @ 36V 0.5 Amps @ 48V Standards:
95 148

Sealed to IP67 SAE J575-Sealed, shock & vibration Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Connector: Mounting: Wiring:


47

Effective Lumens Isolux Charts Flood


20m 20m 0m 0m 20m 20m 0m 25m 50m 0m 50m 100m 40m 0m 50m 100m 150m 0m

Trap
40m

Spot

Part No. 1703731 1703931 1703501 1704311 1704582 1703511


10

Pattern Flood Trap Spot Flood Flood Flood

Lens Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate

Voltage 12-48V 12-48V 12-48V 12-48V 12-48V 12-48V

Light Output White White White White White White

Description Complete worklamp Complete worklamp Complete worklamp Complete worklamp-Marine Complete worklamp-inc switch Complete worklamp-inc switch & harness

L E D 701 Series
Function: Size: Lens: Housing: Worklamp (Vertical Flood) 100 x 140mm oval Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: 776 Lumens Effective: 400 Lumens 12-48V DC 2.0 Amps @ 12V 1.0 Amps @ 24V 0.66 Amps @ 36V 0.5 Amps @ 48V
100

Standards: Connector:
140 193

Sealed to IP67 SAE J575-Sealed, shock & vibration Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Mounting: Wiring:

48

Effective Lumens Isolux Charts Flood


25m 15m 0m 15m 25m 0m 20m 40m 60m 80m

Part No. 1703761

Pattern Flood

Lens Polycarbonate

Voltage 12-48V

Light Output White

Description Complete worklamp

11

L E D 735 Series
Function: Size: Lens: Housing: Worklamp 144 x 95mm oval Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw:
144 80

2700 Lumens

Effective: 1400 Lumens 12 or 24V DC 3.7 Amps @ 12V 1.7 Amps @ 24V Standards: Connector:
95 148

Sealed to IP67 SAE J575-Sealed, shock & vibration Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Mounting: Wiring:

47

Effective Lumens Isolux Charts Flood


35m 20m 0m 0m 20m 35m 20m 40m 60m 40m 0m 40m 100m 50m 100m 150m 200m 300m

Trap

Spot

Part No. 1704611 1704601 1704621 1704641 1704631 1704651


12

Pattern Flood Trap Spot Flood Trap Spot

Lens Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate

Voltage 12V 12V 12V 24V 24V 24V

Light Output White White White White White White

Description Complete worklamp Complete worklamp Complete worklamp Complete worklamp Complete worklamp Complete worklamp

L E D 736 Series
Function: Size: Lens: Housing: Worklamp (Vertical Flood) 144 x 95mm oval Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw:
100

2700 Lumens

Effective: 1400 Lumens 12 or 24V DC 3.7 Amps @ 12V 1.7 Amps @ 24V Standards: Connector:
140 193

Sealed to IP67 SAE J575-Sealed, shock & vibration Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Mounting: Wiring:

48

Effective Lumens Isolux Charts Flood


35m

0m

35m 20m 60m 100m 140m

Part No. 1704911 1704961

Pattern Flood Flood

Lens Polycarbonate Polycarbonate

Voltage 12V 24V

Light Output White White

Description Complete worklamp Complete worklamp

13

Function: Size: Lens: Housing:

Worklamp ??? Glass Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: Standards: Connector: Mounting: Wiring: 5100 Lumens Effective: 3000 Lumens 12 or 24V DC 6 Amps @ 12V 3 Amps @ 24V Sealed to IP67 SAE J575-Sealed, shock & vibration Integrated 2-pin Deutsch weather-proof socket Universal heavy duty mount Supplied with 2-pin Deutsch weather-proof plug with 300mm plug

14

L E D 7150 Series
Effective Lumens Isolux Charts Flood
88m

0m

88m 50m 100m 150m

Trap
50m 0m 50m

worklight pic scene

125m

250m

375m

Spot
100m 0m 100m 250m 500m 750m

Part No. 1715001 1715011 1715021 1715031 1715041 1715051

Pattern Flood Trap Spot Flood Trap Spot

Lens Glass Glass Glass Glass Glass Glass

Voltage 12V 12V 12V 24V 24V 24V

Light Output LED LED LED LED LED LED

Description Worklamp Worklamp Worklamp Worklamp Worklamp Worklamp


15

L E D 783 Series
Function: Size: Lens: Housing: Worklamp (Vertical Flood) 155 x 38mm Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: 720 Lumens Effective: 380 Lumens 12V - 48V DC 1 Amp @ 12V 0.5 Amps @ 24V 0.37 Amps @ 36V 0.25 Amps @ 48V
155

Standards: Connector: Mounting: Wiring:

Sealed to IP67 SAE J575-Sealed, shock & vibration Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

38 54

46

Effective Lumens Isolux Charts Flood


30m

0m

30m 0m 30m 60m 90m 120m

Part No. 0543681

Pattern Flood

Lens Polycarbonate

Voltage 12V - 48V

Light Output White

Description Complete worklamp (Vertical Flood)

16

L E D 783 Series
Function: Size: Lens: Housing: Worklamp 155 x 38mm Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: 720 Lumens Effective: 380 Lumens 12V - 48V DC 1 Amp @ 12V 0.5 Amps @ 24V
54 38

0.37 Amps @ 36V 0.25 Amps @ 48V Standards: Connector: Sealed to IP67 SAE J575-Sealed, shock & vibration Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

46

Mounting: Wiring:
155

Effective Lumens Isolux Charts Flood


30m

0m

30m

0m

30m

60m

90m

120m

Part No. 0543691

Pattern Flood

Lens Polycarbonate

Voltage 12V - 48V

Light Output White

Description Complete worklamp

17

L E D 524 Series
Function: Size: Lens: Housing: Worklamp 221 x 155mm Glass Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: Standards: Connector:
63

8100 Lumens

Effective: 3100 Lumens 12 or 24V DC 7.5 Amps @ 12V 3.8 Amps @ 24V Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Panel/flush mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Mounting: Wiring:

156

221

Effective Lumens Isolux Charts Flood


40m 20m 0m 20m 40m 0m 50m 100m 150m

Part No. 0543312 0543232 ?


18

Pattern Flood Flood -

Lens Glass Glass -

Voltage 12V 24V -

Light Output White White -

Description Complete worklamp Complete worklamp 316 Stainless retaining ring

L E D 522 Series
Function: Size: Lens: Housing: Worklamp 221 x 155mm Glass Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: Standards: Connector: Mounting: Wiring: 8100 Lumens Effective: 3100 Lumens 12 or 24V DC 7.5 Amps @ 12V 3.8 Amps @ 24V Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

63

194

221

32

Effective Lumens Isolux Charts Flood


40m 20m 0m 20m 40m 0m 50m 100m 150m

Part No. 0543331 0543351

Pattern Flood Flood

Lens Glass Glass

Voltage 12V 24V

Light Output White White

Description Complete worklamp Complete worklamp


19

L E D 523 Series
Function: Size: Lens: Housing: Worklamp 221 x 155mm Glass Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: Standards:
178

8100 Lumens

Effective: 3100 Lumens


63

12 or 24V DC 7.5 Amps @ 12V 3.8 Amps @ 24V Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Heavy duty universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Connector: Mounting: Wiring:

254

89

Effective Lumens Isolux Charts Flood


40m 50m 20m 0m 20m 40m 50m 0m 50m 100m 150m 0m 100m 200m 0m 0m

Trap

Spot
50m

50m 0m 100m 200m 250m

Part No. 0543321 0544451 0544551 0544651 0543341 0544481 0544561 0544661
20

Pattern Flood Flood Spot Trap Flood Flood Spot Trap

Lens Glass Glass Glass Glass Glass Glass Glass Glass

Voltage 12V 12V 12V 12V 24V 24V 24V 24V

Light Output White 3200K White White White 3200K White White

Description Complete worklamp Complete worklamp Complete worklamp Complete worklamp Complete worklamp Complete worklamp Complete worklamp Complete worklamp

L E D 708 Series
Function: Size: Lens: Housing: Reverse Light 144 x 95mm oval Polycarbonate Die-Cast

Product Specifications
Light Source: Input Voltage: Current Draw: LED (Light Emitting Diodes) 12-48V DC 2.0 Amps @ 12V 1.0 Amps @ 24V 0.66 Amps @ 36V 0.5 Amps @ 48V Standards:
144

Sealed to IP67 SAE J575-Sealed, shock & vibration E approved

Connector:
95 149 87

Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Mounting: Wiring:

49

Part No. 1705071

Pattern Reverse

Lens Polycarbonate

Voltage 12-48V

Light Output White

Description Complete reverse light

21

HID
HID
8200 Series 8450 Series 9700 Series 8470 Series

22-28
23 24-25 26-27 28

22

H I D 8200 Series
Function: Size: Lens: Housing: Worklamp 124 x 107mm Glass Reinforced Nylon

Product Specifications
Light Source: Light Output:
148 124

HID (High Intensity Discharge) 2100 Lumens 12 or 24V DC 3.3 Amps @ 12V 1.65 Amps @ 48V Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Input Voltage: Current Draw: Standards:

107 146

Connector: Mounting: Wiring:

43

Effective Lumens Isolux Charts


40m

Flood

60m

Trap

20m

30m

0m

0m

20m

30m

40m 0m

50m

100m

150m

60m 0m

50m

100m

150m

200m

Part No. 0543151 0543161 0543191 0543201 85410 6600440 6660450 3154691 3154681

Pattern Flood Trap Flood Trap - - - - -

Voltage 12V 12V 24V 24V - - - - -

Wattage 35W 35W 35W 35W - - - - -

Light Output White White White White - - - - -

Description Complete worklamp Complete worklamp Complete worklamp Complete worklamp 85V 35W Philips D1S bulb 12V Ballast 24V Ballast Flood lens insert Trap lens insert
23

Function: Size: Lens: Housing:

Worklamp 145mm round Glass Reinforced Nylon

Product Specifications
Light Source: Light Output: Input Voltage: Current Draw: Standards: Connector: Mounting: Wiring: HID (High Intensity Discharge) 2100 Lumens 12 or 24V DC 3.3 Amps @ 12V 1.65 Amps @ 48V Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

143

145

81

24

H I D 8450 Series
Effective Lumens Isolux Charts Flood
25m

0m

25m

0m

40m

80m

120m

Trap
25m

worklight pic scene

0m

25m 0m 30m 60m 90m

Spot
30m 0m 30m 0m 100m 200m 300m

Part No. 0540311 0541271 0540291 0540821 0540321 0545271 0540301 0540241 85410 660380 660420 0541471 0541501 0541491

Pattern Flood Flood Trap Spot Flood Flood Trap Spot - - - - - -

Voltage 12V 12V 12V 12V 24V 24V 24V 24V - - - - - -

Wattage 35W 35W 35W 35W 35W 35W 35W 35W - - - - - -

Light Output White White White White White White White White - - - - - -

Description Complete worklamp Complete worklamp-Marine Complete worklamp Complete worklamp Complete worklamp Complete worklamp-Marine Complete worklamp Complete worklamp 85V 35W Philips D1S bulb 12V Ballast 24V Ballast Flood lens insert Trap lens insert Spot lens insert
25

Function: Size: Lens: Housing:

Worklamp 156 x 111mm Glass Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Lumens Standards: Connector: Mounting: Wiring: HID (High Intensity Discharge) 12V or 24V DC 3.3 Amps @ 12 volts 1.65 Amps @ 24 volts Clear lens 2100 lumens Amber lens 1700 lumens Sealed to IP68 Integrated 2-pin Deutsch weather-proof socket Heavy duty universal, stainless mount Pre-wired loom, 2-pin Deutsch weather-proof socket, 740mm cable

163 156

794

203

29 92 76

26

H I D 9700 Series

worklight pic scene Effective Lumens Isolux Charts Flood


40m 40m

Trap
40m 0m

Spot

20m 0m 0m 40m 20m

40m

0m

100m

200m

300m

0m

50m

100m

150m

40m 0m 50m 100m

Part No. 1703121 1704771 1701451 1703131 1703141 1703151 1704101 1705351 1703171 1703161 85410 6600440 6600450 3155021 3155041 3155031 3158870 3254801

Pattern Flood Flood Flood Trap Spot Flood Flood Flood Trap Spot - - - - - - - -

Voltage 12V 12V 12V 12V 12V 24V 24V 24V 24V 24V - - - - - - - -

Wattage 35W 35W 35W 35W 35W 35W 35W 35W 35W 35W - - - - - - - -

Light Output White Amber White White White White Amber White White White - - - - - - - -

Description Complete worklamp Complete worklamp-Amber Complete worklamp-Marine Complete worklamp Complete worklamp Complete worklamp Complete worklamp-Amber Complete worklamp-Marine Complete worklamp Complete worklamp 85V 35W Philips D1S bulb 12V Ballast 24V Ballast Flood lens insert Trap lens insert Spot lens insert Ballast cable 175mm Ballast to bulb cable
27

H I D 8470 Series
Function: Size: Lens: Housing: Hand Held Lamp 145mm Round Glass Reinforced Nylon

Product Specifications
Light Source: Light Output: Input Voltage: Current Draw: Standards: Wiring: HID (High Intensity Discharge) 2100 Lumens 12 or 24V DC 3.3 Amps @ 12V 1.65 Amps @ 48V Sealed to IP67 Model dependant Integrated 2-pin Deutsch weather-proof socket 3m coil cord, auxillary power plug

143

145

295

Part No. 0540221 0542521 0542211 0543461 0542451 85410 660380 660420 6600530
28

Pattern Spot Flood Spot Spot Spot - - - -

Voltage 12V 12V 12V 12V 24V - - - -

Wattage 35W 35W 35W 35W 35W - - - -

Light Output White White White White White - - - -

Description Complete lamp with Deutsch socket Complete lamp with coil cord Complete lamp with coil cord Complete lamp with 12V Battery pack & charger Complete lamp with coil cord 85V 35W Philips D1S bulb 12V Ballast 24V Ballast 12V Battery pack & charger

Halogen
Halogen
6700 Series 833 Series

29-31
30 31

29

H a l o g e n 6700 Series
Function: Size: Lens: Housing: Worklamp 121mm Round Glass Rubber

Product Specifications
Light Source: Input Voltage: Current Draw: Mounting: Wiring:
121 83

Sealed Beam 12V or 24V DC 2.8 Amps @ 12 volts 1.8 Amps @ 24 volts Universal mount Pre-wired with 300mm cable

146

121

Effective Lumens Isolux Charts Flood 12V


15m 20m

Flood 24V

0m

0m

15m

20m 75m 90m

0m

25m

50m

0m

30m

60m

Part No. 1400091 1400131 4411 4589

Pattern Trap Trap - -

Voltage 12V 24V - -

Wattage 35W 50W - -

Description Complete worklamp with sealed beam Complete worklamp with sealed beam PAR36 12V 35W sealed beam 114mm PAR36 24V 50W sealed beam 114mm

30

H a l o g e n 833 Series
Function: Worklamp Size: 113 x 100mm Lens: Glass Housing: Reinforced Nylon

Product Specifications
Light Source: Halogen Input Voltage: 12V or 24V DC Standards: Connector:
113 100

Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Mounting:
51 130 101 112

Wiring:

29

Effective Lumens Isolux Charts Flood


10m 12m

Flood High Output


10m

Flood Whitelight

0m

0m

0m

10m 0m 20m 40m

12m 0m 24m 48m

10m 0m 20m 40m

Part No. 0541551 ? ? 0541561 12336PR

Pattern Flood Flood Flood Flood -

Voltage 12V 12V 12V 24V 12V 12V 12V 24V 24V

Wattage 55W 55W 55W 70W - - - - -

Description Complete worklamp with H3 bulb Complete worklamp with high output H3 bulb Complete worklamp with 4000K white light H3 bulb Complete worklamp with H3 bulb 12V 55W standard halogen H3 bulb 12V 55W high output H3 bulb 12V 55W 4000K white light H3 bulb 24V 70W standard halogen H3 bulb 24V 70W Heavy Duty / Long Life H3 bulb
31

12336GTB1 - 12336BVB1 - 13336 13336ML - -

Marine
Marine
6700 Series 700 Series 8450 Series 9700 Series 900 Series 734 Series

32-38
33 34 35 36 37 38

32

M a r i n e 6700 Series
Function: Size: Lens: Housing: Worklamp (LED) 120mm round Glass Rubber

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: 690 Lumens Effective: 280 Lumens 12-48V DC 1.2 Amps @ 12 volts 0.63 Amps @ 24 volts 0.42 Amps @ 36V 0.315 Amps @ 48 volts
120 83

Standards: Mounting: Wiring:

Sealed to IP67 UL Recognised Universal mount, stainless hardware Pre-wired with 300mm cable

146

120

Effective Lumens Isolux Charts Flood


30m

0m

30m

0m

50m

100m

150m

Part No. 1402861 3153501 3132961

Pattern Flood Flood Flood

Lens Glass Glass Polycarbonate

Voltage 12-48V 12-48V 12-48V

Light Output White White White

Description Complete worklamp - Marine PAR36 LED sealed beam 114mm PAR36 LED sealed beam 114mm
33

M a r i n e 700 Series
Function: Size: Lens: Housing: Worklamp (LED) 144 x 95mm oval Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: 776 Lumens Effective: 400 Lumens 12-48V DC 2.0 Amps @ 12V 1.0 Amps @ 24V 0.66 Amps @ 36V 0.5 Amps @ 48V
144 80

Standards:

Sealed to IP67 SAE J575-Sealed, shock & vibration UL Recognised

Connector:
95 148

Integrated 2-pin Deutsch weather-proof socket Universal mount, stainless hardware Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Mounting: Wiring:

47

Effective Lumens Isolux Charts Flood


20m

0m

20m 0m 25m 50m

Part No. 1704311

Pattern Flood

Lens Polycarbonate

Voltage 12-48V

Light Output White

Description Complete worklamp - Marine

34

M a r i n e 8450 Series
Function: Size: Lens: Housing: Worklamp (HID) 145mm round Glass Reinforced Nylon

Product Specifications
Light Source: Light Output: Input Voltage: Current Draw: Standards:
143

HID (High Intensity Discharge) 2100 Lumens 12 or 24V DC 3.3 Amps @ 12V 1.65 Amps @ 48V Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Universal mount, stainless hardware Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Connector: Mounting: Wiring:

145

81

Effective Lumens Isolux Charts Flood


25m

0m

25m 0m 40m 80m 120m

Part No. 0541271 0545271 85410 660380 660420 0541471

Pattern Flood Flood - - - -

Voltage 12V 24V - - - -

Wattage 35W 35W - - - -

Light Output White White - - - -

Description Complete worklamp Complete worklamp 85V 35W Philips D1S bulb 12V Ballast 24V Ballast Flood lens insert
35

M a r i n e 9700 Series
Function: Size: Lens: Housing: Worklamp (HID) 156 x 111mm Glass Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Lumens:
156 163

HID (High Intensity Discharge) 12V or 24V DC 3.3 Amps @ 12 volts 1.65 Amps @ 24 volts Clear lens 2100 lumens Sealed to IP68 Integrated 2-pin Deutsch weather-proof socket Heavy duty universal, stainless mount Pre-wired loom, 2-pin Deutsch weather-proof socket, 740mm cable

Standards: Connector:
794

Mounting:
203

Wiring:

29 92 76

Effective Lumens Isolux Charts Flood


40m

0m

40m

0m

50m

100m

150m

Part No. 1701451 1705351 85410 6600440 6600450 3155021 3158870 3254801
36

Pattern Flood Flood - - - - - -

Voltage 12V 24V - - - - - -

Wattage 35W 35W - - - - - -

Light Output White White - - - - - -

Description Complete worklamp - Marine Complete worklamp - Marine 85V 35W Philips D1S bulb 12V Ballast 24V Ballast Flood lens insert Ballast cable 175mm Ballast to bulb cable

M a r i n e 900 Series
Function: Size: Lens: Housing: Worklamp (Halogen) 172 x 120mm Glass Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Mounting: Wiring: Halogen Sealed Beam 12V or 24V DC Universal mount, stainless hardware Pre-wired with 300mm cable

172

112 150

38 120

Effective Lumens Isolux Charts Flood


20m

0m

20m 0m 25m 50m 75m

Part No. 1229845 4929401

Pattern Flood -

Voltage 12V -

Wattage 50W -

Light Output White -

Description Complete worklamp-Halogen sealed beam 12V 50W Halogen sealed beam

37

M a r i n e 734 Series
Function: Size: Lens: Housing: Worklamp / Interior light 190 x 145mm Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: Standards: Connector: Mounting: Wiring: 2700 Lumens Effective: 1400 Lumens 12 or 24V DC 3.7 Amps @ 12V 1.7 Amps @ 24V Sealed to IP67 SAE J575-Sealed, shock & vibration Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Effective Lumens Isolux Charts Flood


35m

0m

35m 20m 40m 60m

Part No. 1705181 1705191


38

Pattern Flood Flood

Lens Polycarbonate Polycarbonate

Voltage 12V 24V

Light Output White White

Description Worklamp / Interior Light Flush mount Worklamp / Interior Light Flush mount

L a m p I n s e r t s

Lamp Inserts
Lamp Inserts
6040 Series 6046 Series 6130 Series 8700 Series 8800 Series 890 Series

39-46
40 41 42 43 44 45

39

L a m p I n s e r t s 6040 Series
Function: Size: Lens: LED Worklight Insert 114mm Round (41/2) Glass / Polycarbonate

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage:
79

690 Lumens

Effective: 280 Lumens 12-48V DC 1.2 Amps @ 12V 0.63 Amps @ 24V 0.42 Amps @ 36V 0.315 Amps @ 48V Standards: Wiring: Sealed to IP67, UL Recognized Pre-wired with 100mm cable Current Draw:

114

70

Effective Lumens Isolux Charts Flood


25m 25m

Trap

0m

0m

25m 0m 30m 60m 90m

25m 0m 30m 60m 90m

Part No. 3153501 3152961 3153491

Pattern Flood Flood Trap

Lens Glass Polycarbonate Glass

Voltage 12-48V 12-48V 12-48V

Light Output White White White

Description PAR36 LED sealed beam 114mm PAR36 LED sealed beam 114mm PAR36 LED sealed beam 114mm

40

L a m p I n s e r t s 6046 Series
Function: Size: Lens: LED Worklight Insert 146mm Round (53/4) Glass

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: 1350 Lumens Effective: 620 Lumens @ 12V 660 Lumens @ 24V
79

Input Voltage: Current Draw: Standards: Connector:

12 or 24V DC 3.7 Amps @ 12V Sealed to IP67, UL Recognised Blade or screw terminals

146

70

Effective Lumens Isolux Charts Flood


25m

0m

25m 0m 25m 50m 75m 100m

Part No. 3155111 3155121 3155231 3155241

Pattern Flood Flood Flood Flood

Lens Glass Glass Glass Glass

Voltage 12V 24V 12V 24V

Light Output White White White White

Description Worklamp insert-Par46-Blade terminals Worklamp insert-Par46-Blade terminals Worklamp insert-Par46-Screw terminals Worklamp insert-Par46-Screw terminals
41

L a m p I n s e r t s 6130 Series
Function: Size: Lens: Housing: LED Headlight Insert 114mm Round (41/2) Glass Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Low Beam 1200 Lumens High Beam 2400 Lumens Effective: Low Beam 516 Lumens High Beam 1030 Lumens Input Voltage: Current Draw: 12-24V DC Low Beam 2.25 Amps @ 12V, 1.3 Amps @ 24V High Beam 5.5 Amps @ 12V, 2.6 Amps @ 24V Standards: Connector: Electronic Switching Unit: ECE Reg. 112 (low beam) Sealed to IP67 Integrated Deutsch weather-proof socket

120

91

Effective Lumens Isolux Charts High Beam


100m 0m 100m 0m 200m 400m 600m 800m 1000m 100m 0m 100m 0m 200m 400m 600m

Low Beam

Part No. 0544591 0545031 0842091

Pattern High Beam Low Beam -

Lens Glass Glass -

Voltage 12-24V 12-24V 12-24V

Light Output White White -

Description Headlight insert SAE Headlight insert ECE Electronic switching unit

42

L a m p I n s e r t s 8700 Series
Function: Size: Lens: Housing: LED Headlight Insert 178mm Round (7) Glass Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: 1200 Lumens High Beam 650 Lumens Input Voltage: Current Draw: Standards: 12-24V DC 2.45 Amps @ 12 volts 1.2 Amps @ 24 volts ECE Reg 112 MIL-STD-461 Sealed to IP67 H4 plug adaptor Direct replacement for standard 178mm (7) sealed or semi-sealed headlight inserts Effective: Low Beam 600 Lumens

Wiring: Features:
178

114 128

Effective Lumens Isolux Charts High Beam


50m 0m 50m 0m 200m 400m 600m 800m 50m 0m 50m 0m 200m 400m 600m

Low Beam

Part No. 0544911 ??

Pattern

Lens

Voltage 12-24V

Light Output White

Description Headlight insert-ECE

High/Low Glass

43

L a m p I n s e r t s 8800 Series
Function: Size: Lens: LED Headlight Insert 102 x 152mm (4 x 6) Glass

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: 1500 Lumens High Beam 850 Lumens Input Voltage: Current Draw: Standards: Wiring: 12-24V DC 2.7 Amps @ 12 volts, 1.3 Amps @ 24 volts ECE Reg. 112 Sealed to IP67 H4 plug adaptor Effective: Low Beam 850 Lumens

70

107

168 76 103

Effective Lumens Isolux Charts High Beam


50m 0m 50m 0m 150m 300m 450m 600m 100m 0m 100m 0m 150m 300m 450m

Low Beam

Part No. 0544961 0543811

Pattern Low High

Lens Glass Glass

Voltage 12-24V 12-24V

Light Output White White

Description Low Beam Headlight insert-ECE High Beam Headlight insert-SAE

44

L a m p I n s e r t s 890 Series
Function: Size: Lens: LED Worklamp Insert 76 x 127mm (3 x 5) Polycarbonate

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: 180 Lumens Effective: 120 Lumens 12-48V DC 0.226 Amps @ 12 volts 0.101 Amps @ 28-volts 0.080 Amps @ 36-volts 0.065 Amps @ 48-volts Pre-wired with 120mm cable

Standards: Wiring:
124 112.5

78

82

Effective Lumens Isolux Charts Flood


10m

112

0m

10m 0m 15m 30m 45m

Part No. 0543422

Pattern Flood

Lens Polycarbonate

Voltage 12-48V

Light Output White

Description Floodlamp Worklamp insert

45

Auxillary
Auxillary
734 Series 282 Series 412 Series 419 Series 408 Series 416 Series

46-52
47 48 49 50 51 52

46

A u x i l l a r y 734 Series
Function: Size: Lens: Housing: Worklamp / Interior light 190 x 145mm Polycarbonate Die-Cast

Product Specifications
Light Source: LED (Light Emitting Diodes) Raw: Input Voltage: Current Draw: Standards: Connector: Mounting: Wiring: 2700 Lumens Effective: 1400 Lumens 12 or 24V DC 3.7 Amps @ 12V 1.7 Amps @ 24V Sealed to IP67 SAE J575-Sealed, shock & vibration Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

Part No. 1705181 1705191

Pattern Flood Flood

Lens Polycarbonate Polycarbonate

Voltage 12V 24V

Light Output White White

Description Worklamp / Interior Light Flush mount Worklamp / Interior Light Flush mount

47

A u x i l l a r y 282 Series
Function: Size: Lens: Housing: Interior light 216 x 49mm Acrylic Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Mounting: Wiring:
49

LED (Light Emitting Diodes) 12-24V DC 0.5 Amps @ 12/24 volts Universal mount Pre-wired with 150mm cable

115

195 216

Part No. 0442092

Lens Acrylic

Voltage 12-24V

Light Output White

Description Interior light

48

A u x i l l a r y 412 Series
Function: Size: Lens: Housing: Interior light 165 x 57mm Polycarbonate Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Touch switch panel Current Draw: Standards: Mounting:
57

LED (Light Emitting Diodes) 12-24V DC 280 mAmps @ 12/24 volts Sealed to IP67, UL recognised Universal mount Pre-wired with 150mm cable

Wiring:

165 146

Part No. 0442512 0443012

Lens Polycarbonate Polycarbonate

Voltage 12-24V 12-24V

Light Output White White

Description Interior light Interior light with touch switch

49

A u x i l l a r y 419 Series
Function: Size: Lens: Housing: Interior light 155mm round Polycarbonate Chrome ring

Product Specifications
Light Source: Input Voltage: Current Draw: Standard: Mounting: Wiring: LED (Light Emitting Diodes) 12-24V DC 0.5 Amps @ 12/24 volts IP67 Universal flush mount Pre-wired with 150mm cable

155

36

30

Part No. 0442402 0442771

Lens Polycarbonate Polycarbonate

Voltage 12-24V 12-24V

Light Output White White/Cyan

Description Interior light Interior light-Switchable white to cyan

50

A u x i l l a r y 408 Series
Function: Size: Lens: Housing: LED Engine Light LED Compartment Light 70mm Round Tempered Glass Die-Cast

Product Specifications
Light Source: Input Voltage: Current Draw: Standard: Mounting: Wiring: Features: LED (Light Emitting Diodes) 12-24V DC 0.5 Amps @ 12/24 volts IP67, SAEJ575 Universal mount Pre-wired with 150mm cable Ideal for engine compartment light. This lamp will automatically shut down when temperatures exeed 115o C and will re-light when the temperature has reduced to 110o C or less.

70

90

Part No. 0442502

Lens Tempered Glass

Voltage 12-24V

Light Output White

Description Engine compartment light

51

A u x i l l a r y 416 Series
Function: Size: Lens: Housing: LED Compartment Light LED Step Light 113 x 43mm Polycarbonate Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Standard: LED (Light Emitting Diodes) 12-36V DC 0.5 Amps @ 12/24 volts IP67

SAE J575-Environmental SAE J113/2-Electro magnetic compatability SAE J113/4-Radio distrubance SAE J1455-Environmental Practices Mounting: Wiring: Universal mount Pre-wired with 150mm cable

79

113

43 21

Part No. 0442292 0442302

Lens Polycarbonate Polycarbonate

Voltage 12-36V 12-36V

Light Output White White

Description Black body White body

52

Emergency
Emergency
284 Series 207 Series 538 Series 539 Series 404 Series 405 Series 400 Series 401 Series MB833 MB700

53-63
54 55 56 57 58 59 60 61 62 63

53

E m e r g e n c y 284 Series
Function: Size: Lens: Housing: LED Strobe Lamp Class 3 216 x 50mm Polycarbonate Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Standard: LED (Light Emitting Diodes) 12-48V DC 0.5 Amps Sealed to IP67 SAE J845-Class 3 UL recognised Mounting:
44 50

Universal mount Pre-wired with 150mm cable

Wiring:

216 195

Part No. 0645661

Lens Polycarbonate

Voltage 12-48V

Light Output Amber

Description Amber Strobe - Class 3

54

E m e r g e n c y 707 Series
Function: Size: Lens: Housing: LED Strobe Lamp *Class 2 144 x 95mm Oval Polycarbonate Die-Cast

Product Specifications
Light Source: Input Voltage: Current Draw: Flash Rate: LED (Light Emitting Diodes) 12-48V DC 1.5 Amp *Mode 1 - Flash pattern meets SAE J845 Class 2 with 80o spread Mode 2 - Fast flash Mode 3 - Double flash Mode 4 - Flash burst Mode 5 - Slow single flash *SAE J845 Class 2 warning device Sealed to IP67 Integrated 2-pin Deutsch weather-proof socket Universal mount Supplied with 2-pin Deutsch weather-proof plug with 300mm cable

144

80

Standard:
95 148

Connector: Mounting: Wiring:

47

Part No. 1704221

Lens Polycarbonate

Voltage 12-48V

Light Output Amber

Description Amber LED Strobe Lamp - *Class 2

55

E m e r g e n c y 538 Series
Function: Size: Lens: Housing: LED Strobe Lamp Class 3 71mm Round Acrylic Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Flash Rate: Standard: Mounting: Wiring: LED (Light Emitting Diodes) 12-80V DC 0.5 Amp _ 60 + 10fpm SAE J845 Class 3 warning device UL Recognised Pipe mount Pre-wired with 150mm cable

107 71

Part No. 0645011

Lens Acrylic

Voltage 12-80V

Light Output Amber

Description Amber LED Strobe Lamp - Pipe mount

56

E m e r g e n c y 539 Series
Function: Size: Lens: Housing: LED Strobe Lamp *Class 3 71mm Round Acrylic Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Flash Rate: Standard: LED (Light Emitting Diodes) 12-80V DC 0.5 Amp _ 60 + 10fpm *SAE J845 Class 3 warning device (Amber only) UL Recognised Pipe mount Pre-wired with 150mm cable

71

Mounting: Wiring:

112

Available Lens Colours

Part No. 0644871 0645091 0645101 0645111 0645161

Lens Acrylic Acrylic Acrylic Acrylic Acrylic

Voltage 12-80V 12-80V 12-80V 12-80V 12-80V

Light Output Amber Red Green Blue Clear

Description Amber LED Strobe Lamp - *Class 3 Red LED Strobe Lamp Green LED Strobe Lamp Blue LED Strobe Lamp Clear LED Strobe Lamp
57

E m e r g e n c y 404 Series
Function: Size: Lens: Housing: LED Strobe Lamp *Class 2 110mm Round Acrylic Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Flash Rate: LED (Light Emitting Diodes) 12-24V or 36-72V DC 1.0 Amp Mode 1 - 240fpm Mode 2 -340fpm Mode 3 - 540fpm Mode 4 - Operates as rotating beacon Standard: SAE J575-Environmental *Flash mode 1 (Amber only) meets SAE J845 Class 2 Universal mount Pre-wired with 150mm cable Red = Positive Black = Negative Yellow = Mode change

Mounting: Wiring:
114

110

Available Lens Colours

Part No. 0645201 0645271 0645281 0645681


58

Lens Polycarbonate Polycarbonate Polycarbonate Polycarbonate

Voltage 12-24V 12-24V 12-24V 36-72V

Light Output Amber Blue Red Amber

Description Amber LED Strobe Lamp Blue LED Strobe Lamp Red LED Strobe Lamp Amber LED Strobe Lamp

E m e r g e n c y 405 Series
Function: Size: Lens: Housing: LED Strobe Lamp *Class 1 130mm Round Acrylic Die-Cast

Product Specifications
Light Source: Input Voltage: Current Draw: Flash Rate: LED (Light Emitting Diodes) 12-80V DC 1.0 Amp Mode 1 - 240fpm Mode 2 -340fpm Mode 3 - 540fpm Mode 4 - Operates as rotating beacon Standard: Sealed to IP65 *Flash mode 1 (Amber only) meets SAE J845 Class 1 warning device ECE Reg 65 Special warning lights Universal mount Pre-wired with 150mm cable Red = Positive Black = Negative Yellow = Mode change

127

Mounting: Wiring:

130

Available Lens Colours

Part No. 0645531 0645731 0645711 0645721 7041050

Lens Polycarbonate Polycarbonate Polycarbonate Polycarbonate -

Voltage 12-80V 12-80V 12-80V 12-80V -

Light Output Amber Blue Red Green -

Description Amber LED Strobe Lamp Blue LED Strobe Lamp Red LED Strobe Lamp Green LED Strobe Lamp Magnetic Base to suit 405 series
59

E m e r g e n c y 400 Series
Function: Size: Lens: Housing: Strobe Lamp 125mm round Polycarbonate Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Flash Energy: Flash Rate: Standard: Mounting: Wiring: Xenon Flash Tube 12-80V DC 0.65 Amps @ 12V 0.15 Amps @ 80V 2.5 Joules @12V 0.5 Amps _ 60 + 10fpm UL recognised, CE Mark Universal mount Pre-wired with 150mm cable

98

112

114

74

125

Available Lens Colours

Part No. 0644051 3148681 4429681 4429690 4429710 4429700


60

Lens Polycarbonate - - - - -

Voltage 12-80V - - - - -

Light Output Amber - - - - -

Description Amber Strobe Lamp Xenon Flash Tube Amber Lens Red Lens Blue Lens Clear Lens

E m e r g e n c y 401 Series
Function: Size: Lens: Housing: Strobe Lamp 125mm round Polycarbonate Reinforced Nylon

Product Specifications
Light Source: Input Voltage: Current Draw: Flash Energy: Flash Rate: Standard: Mounting: Wiring:
98

Xenon Flash Tube 12-80V DC 0.65 Amps @ 12V 0.15 Amps @ 80V 2.5 Joules @12V 0.5 Amps _ 60 + 10fpm UL recognised, CE Mark Magnetic base 1.2m coil cord, auxillary power plug

74 112 124

125

Available Lens Colours

Part No. 0644111 3148681 4429681 4429690 4429710 4429700

Lens Polycarbonate - - - - -

Voltage 12-80V - - - - -

Light Output Amber - - - - -

Description Amber Strobe Lamp, Magnetic Base Xenon Flash Tube Amber Lens Red Lens Blue Lens Clear Lens
61

E m e r g e n c y MB833 Series
Function: Size: Mining Light Bar 1200mm

Light bar includes the following products


1 x 1200mm steel support bar 1 x 405 Series 12-80V amber LED strobe 2 x 833 Series 12V halogen worklamps 1 x 300 Series 12-80V back-up alarm 2 x 280 Series 12V rear combination lamps Mounting: Attaches to existing roof rack systems Wiring: Pre-wired with 4m cable

Part No. 0323301 0645531 0541551 1100141 0341022


62

Description Complete 12V Mining bar 405 Series amber LED strobe lamp 833 Series 12V halogen worklamps 300 Series 12-80V back-up alarm 280 Series 12V rear combination lamps

E m e r g e n c y MB700 Series
Function: Size: Mining Light Bar 1200mm

Light bar includes the following products


1 x 1200mm steel support bar 1 x 405 Series 12-80V amber LED strobe 2 x 700 Series 12-48V LED worklamps 1 x 300 Series 12-80V back-up alarm 2 x 280 Series 12V rear combination lamps Mounting: Attaches to existing roof rack systems Wiring: Pre-wired with 4m cable

Part No. 0343291 0645531 1703731 1100141 0341022

Description Complete 12-24V Mining bar 405 Series amber LED strobe lamp 700 Series 12-48V LED worklamps 300 Series 12-80V back-up alarm 280 Series 12V rear combination lamps
63

B ackup Alar m
Backup Alarm
300 Series 380 Series 390 Series

64-67
65 66 67

64

B A C K U P A L A R M 300 Series
Function: Size: Housing: Backup Alarm (97dB) 102 x 41mm Reinforced Nylon

Product Specifications
Input Voltage: Current Draw: Standards: Mounting: 12V-80V DC 0.6 Amps SAE J994-backup alarm Any position except face up

41

84 84

70

102

Part No. 1100141

dB 97

Voltage 12-80V

Description Backup alarm

65

B A C K U P A L A R M 380 Series
Function: Size: Housing: Backup Alarm (112dB) 127 x 84mm Reinforced Nylon

Product Specifications
Input Voltage: Current Draw: Standards: Mounting: 12V-24V DC 0.8 Amps SAE J994-backup alarm Any position except face up

127

51 102 84

Part No. 1100161

dB 112

Voltage 12-24V

Description Backup alarm

66

B A C K U P A L A R M 390 Series
Function: Self Adjusting Backup Alarm (82-107dB) Size: 125 x 75mm Housing: Reinforced Nylon

Product Specifications
Input Voltage: Standards: Mounting: Features: 12V-48V DC SAE J994-backup alarm Any position except face up This alarm is self-adjusting based on the amount of noise in the surrounding area. This keeps it at safe levels while reducing noise irritation for operators and workers. Current Draw: 0.6 Amps

82 125

75

Part No. 1100151

dB 82-107

Voltage 12-48V

Description Self Adjusting Backup alarm

67