Power solutions

> X & S series product range Fully integrated, reliable and efficient Dependable service, engineering expertise and parts support

Our energy working for you.TM

With over 80 years experience in power generation and an extensive global distributor network across 130 countries, we are ready to match the right generating, transfer and control technologies with your power needs - be it continuous, prime, peaking, standby, cogeneration, or a complete turnkey power plant. Part of Cummins Inc. which has a turnover of over US$ 11 billion, Cummins Power Generation has the global resources to meet your unique power needs.

Global leader
Contents Diesel generator sets -15 to 70 kVA............................. 3 Enclosures .................................................................... 4 PowerCommand and Power electronics .................... 5 Fully integrated reliable efficient Cummins Power Generation is a world leader in the design and manufacture of pre-integrated generator sets, transfer switches, paralleling equipment and controls for use in standby, prime and continuous rated systems. All major components the engine, alternator and control systems are manufactured by divisions of Cummins. This integral approach means each element of a generating set is designed to work in harmony from the start. A high quality product, coupled with unrivalled reliability, gives industry leading power solutions. Global strengths, local partnership With a worldwide distribution network across 130 countries, with approaching 500 dealers and 4,500 service/ parts outlets, we have the capability and experience to support our products wherever they are operating. As a Cummins Power Generation user, you can expect a face to face relationship with someone worthy of your trust and fast access to reliable service, engineering expertise and parts support. Service outlets are spread strategically across the world with technicians trained to the highest standards. So wherever you need fully integrated, reliable and efficient power, call your local Cummins Power Generation distributor.

3 Cummins engine powered generating sets are available at competitive prices and offer the best fuel economy, best warranty terms and lowest cost of maintenance, replacement and overhaul parts, thereby proving to be the most economical power solution.

Diesel generator sets - 15 to 70 kVA Cummins powered X and S series diesel generator sets are available in size ranging from 15 to 70 kVA. A high quality product, manufactured in accordance with the international standards, coupled with unrivalled reliability gives industry leading power solutions. X series X series Ready-to-Use generator sets with 2 and 3 cylinder inline configuration diesel engines are the most compact, light weight and easy to service products. Built-in vibration mounts, a completely wired control system including engine protection, instrumentation, industrial silencer and integral fuel tank are part of its special features. Engines in this series are naturally aspirated, fuel efficient, with low lube oil consumption.
50 Hz rating Genset model ES 17 D5 ES 22 D5 ES 28 D5 60 Hz rating Genset model ES 12 D6 ES 16 D6 ES 20 D6

Engine model X 1.7 G1 X 2.5 G1 X 2.5 G2

Prime kVA / kW 15 / 12 20 / 16 25 / 20

Standby kVA / kW 16.5 / 13 22 / 18 27.5 / 22

Engine model X 1.7 G2 X 2.5 G4 X 2.5 G4

Prime kVA / kW 13.5 / 11 18 / 14.5 22.5 / 18

Standby kVA / kW 15 / 12 20 / 16 25 / 20

* Alternator Model/Frame size are subject to change without notification. Please verify this at the time of order . 60 Hz models are Tier 2 certifiable. Rating Definition: Prime Power Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO8528-1. A 10% overload capability is available for a period of 1 hour within 12-hour period of operation, in accordance with ISO3046-1. Standby Power Rating Standby Power Rating is applicable for supplying emergency power for the duration of a utility power interruption.No overload,utility parallel or negotiated outage operation capability is available at this rating. In installations served by unreliable utility sources (where outages last longer or occur more frequently),where operation is likely to exceed 200 hours per year, the prime power should be applied.All ratings are based on the following reference conditions:Ambient temperature - 27oC (Altitude above sea level - 150 metres) Relative humidity - 60%

S series The S series generator sets with 4 cylinder inline configuration diesel engines are naturally aspirated, turbocharged and aftercooled. Engines in this series are simple, compact, reliable, fuel efficient and have minimal noise and vibration levels.

50 Hz rating Genset model ES 33 D5 ES 38 D5 ES 43 D5 ES 55 D5 ES 68 D5 60 Hz rating Genset model ES 30 D6 ES 35 D6 ES 38 D6 ES 48 D6 ES 61 D6

Engine model S 3.8 G2 S 3.8 G3 S 3.8 G4 S 3.8 G6 S 3.8 G7

Prime kVA / kW 30 / 24 35 / 28 40 / 32 50 / 40 62 / 50

Standby kVA / kW 33 / 26 38 / 30 43 / 35 55 / 44 68 / 55

Engine model S 3.8 G2 S 3.8 G3 S 3.8 G4 S 3.8 G6 S 3.8 G7

Prime kVA / kW 35 / 28 40 / 32 43 / 35 55 / 44 70 / 56

Standby kVA / kW 38 / 30 43 / 35 47 / 38 60 / 48 76 / 61

Enclosures
All Cummins Power Generation diesel generator sets up to 70 kVA are available with weather protective and sound attenuated enclosures. All enclosures cover and protect the generator set. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability have not been compromised. All enclosures provide easy access to service points and provide operators with plenty of room for maintenance.

All sound attenuated enclosures are made of 1.6/2 mm thick CRCA sheets and structural sheet metal base frame painted in Munsel green shade. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 80 dBA at 1 mtr sound levels. All enclosures are designed to provide optimal genset performance and sound-treatment. This results in achieving the lowest noise level possible without compromising performance.

X series - 50 & 60 Hz ratings


Genset model Length (mm) 1850 1850 1850 1850 1850 1850 Width (mm) 900 900 900 900 900 900 Height (mm) 1375 1375 1375 1375 1375 1375 Weight (kgs) dry 810 860 885 810 840 860 dBA @ 1 mtr 80 80 80 80 80 80 Sound level @ 100% load dBA LWA @ 7 mtr 63 96 63 96 63 96 63 63 63 -

ES 17 D5 ES 22 D5 ES 28 D5 ES 12 D6 ES 16 D6 ES 20 D6

Major features include: 80 dBA at 1 mtr Compact footprint, low profile design Easy access to all major generator, engine control components for servicing q Enclosed, protective exhaust systems q CE compliant
q q q

S series - 50 & 60 Hz ratings


Genset model Length (mm) 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300 Width (mm) 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 Height (mm) 1650 1650 1650 1650 1650 1650 1650 1650 1650 1650 Weight (kgs) dry 1200 1200 1250 1300 1350 1200 1200 1250 1300 1350 Sound dBA @ 1 mtr 80 80 80 80 80 80 80 80 80 80 level @ 100% load dBA LWA @ 7 mtr 63 97 63 97 63 97 63 97 63 97 63 63 63 63 63

ES 33 D5 ES 38 D5 ES 43 D5 ES 55 D5 ES 68 D5 ES 33 D6 ES 38 D6 ES 43 D6 ES 55 D6 ES 68 D6

PowerCommand and Power electronics

PCC 0300

PCC 1301
Main features PCC 1301 Engine protection Main features PCC 1301 Power transfer function

Main features

Model PCC 0300

Model PCC 0300

Model PCC 0300 PCC 1301

General

Integrated electronic governing


Human machine interface

Low fuel level High fuel level High oil temperature Low engine coolant temp. Failure to crank shutdown Over crank (failure to start) Over speed Low battery voltage alarm High battery voltage alarm Battery alternator charge fault
Alternator protection

Open transition transfer Hard closed transition Soft closed transition (ramping) Transfer & base load (utility) Gen / mains breaker control Gen / mains breaker status
Miscellaneous

Integrated AVR Manual start / stop Auto / remote start Test run - manual Test run - auto Emergency stop Alpha / numeric Screen Discrete status indicators Fault reset
Engine measurements/ instrumentation

Operating temperature range -40oC to +70 o C CE marked Common fault alarm CAN bus RS232 Date and time stamp for alarm LonWorks

Under over frequency Reverse power Reverse VAr Overcurrent Short circuit Earth leakage Phase sequence
Paralleling capacity

Oil pressure Oil temperature Water temperature Engine speed Hours run Number of starts Battery voltage Exhaust temperature
Alternator measurements/ instrumentation

Standard Not available Option Under frequency only

Auto synchronising (isolated bus) Isochronous kW & VAr load sharing control Auto synchronising (utility bus) Based load (utility bus) Synchroscope Peak lopping

3 phase voltage & frequency 3 phase current kWh Total kVA Total kW & kVAr PF Per phase kVAr, kW Per phase kVA

GTEC GTEC series transfer switches covering the range 40 to 1250 amps - provide normal and generator set source monitoring, generator set starting, and load transfer functions for emergency, standby, and optional standby applications. GTEC transfer switches are continuously rated, so they can be applied in applications up to their nameplate rating. The transfer switch power contacts are silver alloy composition with high pressure design that can withstand thousands of switching cycles without burning, pitting or welding. They require no routine contact maintenance and provide 100% continuous current ratings. The transfer switch control is reliable and easy to understand, utilizing LED lamps for status indications, and push-button controls for operator functions. The control is field-programmable without the use of service tools.

Asia Pacific 10 Toh Guan Road #07-01 TT International Tradepark Singapore 608838 Phone: 65 6417 2388 Fax: 65 6417 2399 Brazil Rua Jati, 310, Cumbica Guarulhos, SP 07180-900 Brazil Phone: 55 11 2186 4195 Fax: 55 11 2186 4729

China 8 Wanyuan Street Beijing Economic and Technological Dev. Area Beijing 100176 P.R. China Phone: 86 10 6788 2258 Fax: 86 10 6788 2285 Europe, CIS, Middle East and Africa Manston Park Columbus Ave. Manston Ramsgate Kent CT 12 5BF United Kingdom Phone: 44 1843 255000 Fax: 44 1843 255902

India 35A/1/2, Erandawana Pune 411 038 India Phone: 91 020 6602 7525 Fax: 91 020 6602 8090 Latin America 3350 Southwest 148th Ave. Suite 205 Miramar, FL 33027 USA Phone: 954 431 5511 Fax: 954 433 5797

Mexico Eje 122 No. 200 Zona Industrial San Luis Potos, S.L.P. 78090 Mexico Phone: 52 444 870 6700 Fax: 52 444 824 0082 North America 1400 73rd Ave. NE Minneapolis, MN 55432 USA Phone: 763 574 5000 Toll-free: 877 769 7669 Fax: 763 574 5298

Visit us at www.cumminspower.com

Our energy working for you.TM

www.cumminsindia.com
2006 Cummins Power Generation is a registered trademark of Cummins Inc. PowerCommand and Our energy working for you. are trademarks of Cummins Power Generation. Cummins is a registered trademark of Cummins Inc. All other trademarks are owned by their respective companies. Specifications are subject to change without notice. PGBU/01/Power Solutions/90deg./February 2007