litres

mm

(in)

(in3)

(in)

mm

(in) mm

(in)

Weight / Poids
Gewicht / Peso
Peso / Peso

mm

(in)

Height / Hauteur
Hhe / Altezza
Altura / Altura

Length / Longueur
Lnge / Lunghezza
Longitud
Comprimento

mm

Width / Largeur
Breite / Larghezza
Anchura / Largura

Cubic capacity
Cylindre / Hubraum
Cilindrata / Cilindrada
Cilindrada

(lb ft) rev/min

Stroke / Course
Hub / Corsa
Carrera del pistn
Curso

(hp) rev/min Nm

10.2 - 225 kW
13.7 - 301.7 hp

Bore / Alsage
Bohrung / Alesaggio
Dimetro interior
Dimetro

kW

Maximum Torque
Gamme de Couple
Max Drehmoment
Coppia massima
Par mximo
Torque Mximo

Engine
Moteur
Motortyp
Motore
Motor
Motor

Maximum Power
Gamme de Puissance
Max Leistung
Potenza massima
Potencia mxima
Potncia Mxima

Aspiration / Aspiration
Verbrennungsluftzufuhr
Aspirazione / Aspiracin
Aspirao
Cylinder / Cylindre
Zylinder / Cillindri
Cillindro / Cilindros

Perkins Industrial Power Selector


Perkins Industriel Selection de Puissance
Perkins Industriemotoren-Typentabelle
Selettore di Potenza Industriale Perkins
Selector de potencia para uso industrial Perkins
Seletor de Potncia Industrial Perkins

kg

(lbs)

400 Series
*402D-05

10.2 (13.7)

3600 29.7 (21.9)

2400

NA

67

(2.6) 72

(2.8) 0.51

(31) 407

(16) 371 (14.6) 523 (20.6) 57

(126)

*403D-07

15.3 (20.5)

3600 44.5 (32.8)

2200

NA

67

(2.6) 72

(2.8) 0.76 (46.4) 480 (18.9) 371 (14.6) 528 (20.8) 71

(156.5)

*403D-11#

21

(28.2) 3400 70.2 (51.8)

2300

NA

77

(3) 81

*403D-15#

25.1 (33.7)

(70.8)

1800

NA

84

*403D-15T

30

(40.2) 3000 111.9 (82.5)

1800

*403D-17

26.1

(35)

2600 106 (78.1)

1800

NA

*404D-15

26.5 (35.5)

3000 94.4 (69.6)

1700

*404D-22#

38

(51)

3000 143 (105.5)

*404D-22T#

45.5

(61)

3000 189 (139.4)

*404D-22TA#

(3.2) 1.13

(69) 491 (19.3) 400 (15.7) 576 (22.7) 87

(3.3) 90

(3.5) 1.5

(91) 572 (22.5) 453 (17.8) 643 (25.3) 149

(328.5)

84

(3.3) 90

(3.5) 1.5

(91) 572 (22.5) 541 (21.3) 643 (25.3) 156

(345)

84

(3.3) 100

(3.9) 1.662(101.4) 564 (22.2) 453 (17.8) 654 (25.7) 160

(352.7)

NA

77

(3) 81

(3.2) 1.51

(235.5)

1800

NA

84

(3.3) 100

(3.9) 2.216 (135) 664 (26.1) 459

1800

84

(3.3) 100

49.3 (66.1)

2800 208.4(153.7) 1800

TA

84

854E-E34TA

86 (115.3)

2500 420 (309.8) 1600

TA

854F-E34T

55.4 (74.3)

2500 310 (228.6) 1600

3000 96

(92) 591 (23.3) 420 (16.5) 576 (22.7) 107

(191)

(18) 725 (28.5) 184

(406)

(3.9) 2.216 (135) 660

(26) 531 (20.9) 725 (28.5) 194

(427.7)

(3.3) 100

(3.9) 2.216 (135) 660

(26) 531 (20.9) 725 (28.5) 194

(427.7)

99

(3.9) 110

(4.3) 3.4 (207.5) 570 (22.4) 651 (25.6) 680 (26.7) 270

(595.2)

99

(3.9) 110

(4.3) 3.4 (207.5) 570 (22.4) 651 (25.6) 680 (26.7) 275

(606.3)

NA

105

(4.1) 127

(5) 4.4

(269) 768 (30.2) 558

(22) 795 (31.3) 357

(787)

850 Series

1100A Series
1104A-44#

63.5 (85.2)

2200 293

(216) 1400

1104A-44T#

80.5 (108)

2200 404

(298)

1400

105

(4.1) 127

(5) 4.4

(269) 768 (30.2) 558

(22) 947 (37.3) 372

(820)

1100C Series
1103C-33

43

(57.7)

2200 222

(164)

1400

NA

105

(4.1) 127

(5) 3.3

(202) 546 (21.5) 574 (22.5) 826 (32.5) 264

(582)

1103C-33T

55

(73.8)

2200 291

(215)

1400

105

(4.1) 127

(5) 3.3

(202) 546 (21.5) 586 (23.1) 826 (32.5) 276

(608.4)

1104C-44#

64

(85.8)

2400 308

(227)

1200

NA

105

(4.1) 127

(5) 4.4

(269) 663 (26.1) 470 (18.5) 812

(32) 357

(787)

1104C-44T#

74.5 (99.9)

2300 413

(305)

1350

105

(4.1) 127

(5) 4.4

(269) 663 (26.1) 597 (23.5) 810 (31.9) 372

(820)

1104C-44TA#

97 (130.1)

2200 500

(369)

1400

TA

105

(4.1) 127

(5) 4.4

(269) 663 (26.1) 602 (23.7) 775 (30.5) 372

(820)

(582)

1100D Series
1103D-33

36.9 (49.5)

2200 196

(145)

1400

NA

105

(4.1) 127

(5) 3.3

(202) 546 (21.5) 571 (22.5) 826 (32.5) 264

1103D-33TA

60

(80.5)

2200 320

(236)

1400

TA

105

(4.1) 127

(5) 3.3

(202) 546 (21.5) 586

(23) 826 (32.5) 276

(608.4)

1104D-44

56

(75.1)

2200 260

(192)

1650

NA

105

(4.1) 127

(5) 4.4

(269) 663 (26.1) 470 (18.5) 810 (31.9) 357

(787)

1104D-44T#

70

(93.8)

2200 392

(289)

1400

105

(4.1) 127

(5) 4.4

(269) 663 (26.1) 597 (23.5) 810 (31.9) 372

(820)

1104D-44T**

74.5 (99.9)

2200 392

(289)

1400

105

(4.1) 127

(5) 4.4

(269) 663 (26.1) 597 (23.5) 810 (31.9) 372

(820)

1104D-E44T#

74.5 (99.9)

2200 420

(309)

1400

105

(4.1) 127

(5) 4.4

(269) 631 (24.8) 646 (25.4) 823 (32.4) 395

(870.8)

1104D-44TA

83

(111)

2200 418

(308)

1400

TA

105

(4.1) 127

(5) 4.4

(269) 663 (26.1) 620 (24.4) 775 (30.5) 372

(820)

1104D-E44TA#

106

(142)

2200 556

(410)

1400

TA

105

(4.1) 127

(5) 4.4

(269) 631 (24.8) 626 (26.6) 958 (37.7) 395

(870.8)

1106D-E66TA#

186

(249)

2200 1050 (774)

1400

TA

105

(4.1) 127

(5) 6.6

(403) 929 (36.5) 668 (26.2) 797 (31.4) 506 (1115.5)

1106D-E66TA**

>205(>275)

2200 952

(702)

1400

TA

105

(4.1) 127

(5) 6.6

(403) 929 (36.5) 668 (26.2) 797 (31.4) 506 (1115.5)

1204E-E44TA#

110.1(147.6) 2200 560

(413)

1400

TA

105 (4.13) 127

(5) 4.4

(269) 845.1 (33.3) 772.4 (30.4) 848.2 (33.4) 400

(881.8)

1204E-E44TTA#

129.4(173.5) 2200 750 (553.2)

1400

TTA

105 (4.13) 127

(5) 4.4

(269) 845.1 (33.3) 741.6 (29.1) 867.6 (34.1) 450

(992)

1206E-E66TA

129.4(173.5) 2200 825 (608.5)

1400

TA

105 (4.13) 127

(5) 6.6

(403) 1064 (41.9) 753 (29.6) 907 (35.7) 695

(1532)

1206E-E70TTA#

225 (301.7)

1400

TTA

105 (4.13) 135

(5.3) 7.01 (427.7) 1064 (41.9) 820.2 (32.3) 907 (35.7) 715

(1576)

1200E Series

2200 1274(939.6)

** Special Application

Available at 2400rpm
# IOPU available / IOPU disponible / IOPU-Ausfhrung lieferbar / IOPU disponibile / IOPU disponible / IOPU disponvel
*
Indirect injection / Injection indirecte / Indirekte Einspritzung / Iniezione Indiretta / Inyeccin indirecta / Injeo indireta
Dimensions and engine weight are for reference only and will depend on the final specification. For further details refer to the Engine Specification Manual / Les dimensions et le poids du moteur ne sont donns qu titre de rfrence et dpendront de
la configuration finale. Pour davantage de renseignements, veuillez vous reporter au manuel de spcifications du moteur / Die Abmessungen und das Motorgewicht dienen nur zu Referenzzwecken und hngen von den endgltigen Spezifikationen ab.
Weitere Informationen sind dem Spezifikationen-Handbuch des Motors zu entnehmen / Le dimensioni ed il peso del motore illustrati sono solo un riferimento, i valori effettivi dipenderanno dalle specifiche finali. Consultare il manuale delle specifiche
motore per ulteriori dettagli / Las dimensiones y el peso del motor se indican slo para referencia y dependern de las especificaciones finales. Para obtener ms detalles, consulte el Manual de Especificaciones del motor / As dimenses e o peso do
motor so apenas para referncia e dependero da especificao final. Para obter maiores detalhes favor consultar o Manual de Especificao de Motor

Legend
1.
Maximum power to ISO/TR 14396. Barometric pressure 100 kPa / air inlet temperature 25oC. Vapour pressure 1 kPa
2.
Bare engine weight (dry)
Power data refers to run-in engines (60 hours)
NA
T
TA
C
D
E

Naturally aspirated
Turbocharged
Turbocharged air to air aftercooled
Emissions 97/68 EC Stage 2 - various cycles / USA 40 CFR Part 89, 112 Stage 2 various cycles
Emissions 97/68 EC Stage 3A - various cycles / USA 40 CFR Part 89, Tier 3 various cycles
Electronic engine control

All information in this document is substantially correct at the time of printing but may be altered subsequently by the company.
Lgende
1.
Puissance maximum selon norme ISO/TR 14396. Pression Baromtrique 100 kPa / temprature de lair admis 25oC. Pression vapeur 1 kPa
2.
Poids moteur nu (sec)
Les caractristiques se rapportent des moteurs rods (60 heures)
NA
T
TA
C
D
E

Aspiration naturelle
Turbocompress
Turbocompress inter refroidi air/air
Emissions 97/68 EC Stage 2 - differents cycles / USA 40 CFR Part 89, 112 Stage 2 differents cycles
Emissions 97/68 EC Stage 3A - various cycles / USA 40 CFR Part 89, Tier 3 various cycles
Control electronique moteur

Toutes les informations donnes dans ce document sont correctes la date dimpression mais pourront tre modifies ulterieurement par la socit.
Erluterungen
1.
Brutto-Leistung nach ISO/TR 14396. Luftdruck 100 kPa / lufttemperatur 25oC. Dampfdruck 1 kPa
2.
Gewicht Grundmotor (trocken)
Die Leistungsangaben beziehen sich auf eingelaufene Motoren (60 Stunden)
NA
T
TA
C
D
E

Selbstansaugend
Turboaufgeladen
Turboaufgeladen, ladeluftgekhlt (luft/luft)
Emissionswerte nach EU 97/68 Stufe 2 und USA 40 CFR Part 89, 112 Stufe 2
Emissions 97/68 EC Stage 3A - various cycles / USA 40 CFR Part 89, Tier 3 various cycles
Elektronische Motorregelung

Alle angegebenen Werte entsprechen dem letzten Stand vor Druck der Tabelle. Technische nderungen sind im Zuge der technischen Weiterentwicklung vorbehalten.
Leggenda
1.
Potenza Massima secondo norme ISO/TR 14396. Pressione Barometrica 100 kPa / temperatura aria in aspirazione 25oC. Pressione del vapore 1 kPa
2.
Peso motore senza volano (a secco)
I dati di potenza si riferiscono a motori rodati (60 ore)
NA
T
TA
C
D
E

Aspirazione naturale
Turbocompresso
Turbocompresso con post-refrigeratore aria-aria
Emissioni 97/68 EC Stage 2 - cicli varie / USA 40 CFR Part 89, 112 Stage 2 cicli varie
Emissions 97/68 EC Stage 3A - various cycles / USA 40 CFR Part 89, Tier 3 various cycles
Controllo motore elettronico

Tutti i dati contenuti in questo documento sono corretti al momento della stampa ma potranno subire modifiche successive de parte della casa costruttrice.
Aclaraciones
1.
Potencia mxima a ISO/TR 14396. Presin baromtrica 100 kPa / temperatura de admisin de aire 25oC. Presin de vapor 1 kPa
2.
Peso del motor en vacio (sin Diesel)
La informacin sobre potencia se refiere al tiempo de funcionamiento (60 horas)
NA
T
TA
C
D
E

Aspiracin natural
Turbo
Refrigeracin aire-aire
Emisiones 97/68 EC Stage 2 - varios ciclos / USA 40 CFR Part 89, 112 Stage 2 varios ciclos
Emissions 97/68 EC Stage 3A - various cycles / USA 40 CFR Part 89, Tier 3 various cycles
Control electrnico del motor

Toda la informacin contenida en este documento es correcta en el momento de su impresin, sin embargo la empresa se reserva el derecho
de alteraria en cualquier momento.

Legenda
1.
Potncia mxima de acordo com a norma ISO/TR 14396. Presso baromtrica 100 kPa / temperatura do ar de admisso 25C. Presso de vapor 1 kPa
2.
Peso do motor vazio (sem fluidos)
Os dados de potncia referem-se a motores amaciados (60 horas)
NA
- Aspirao natural
T
- Turboalimentado
TA
- Turboalimentado com ps-arrefecedor ar-ar
C
- Emisses 97/68 EC Stage 2 vrios ciclos / USA 40 CFR Part 89, 112 Stage 2 vrios ciclos
D
- Emisses 97/68 EC Stage 3A vrios ciclos / USA 40 CFR Part 89, Tier 3 vrios ciclos
E
- Controle eletrnico do motor
Todas as informaes neste documento esto corretas na data da sua impresso, mas podem ser alteradas a qualquer momento pela companhia

Perkins Engines Company Limited


Peterborough PE1 5NA United Kingdom
Tel: +44 (0)1733 583000
Fax: +44 (0)1733 582240
www.perkins.com
All information in this document is substantially correct at time of printing and may be altered subsequently
Publication No.1729/10/10 produced in England Perkins Engines Company Limited 2010

Gen Set Power Selector Chart


Model offering for Unregulated Territories
2010 Issue 2

50Hz
Model

Typical
Generator Typical
Efficiency Power
Factor
Standby
%
kWm

Typical Generating
Set Output

Net Engine Output


Baseload
kWm

Prime
kWm

Baseload

Prime
kWe

kVA

Standby
kWe
kVA

kWe

kVA

*
*
*
*
*

*
*
*
*
*

6.6
9.9
14.2
17.6
26.5

8.3
12.3
17.7
21.9
33.1

7.3
10.8
15.6
19.3
29.1

9.1
13.5
19.5
24.1
36.4

1500/1800
rev/min
switchable

3000 rev/min (8.3 kVA to 36.4 kVA)


402D-05G
403D-07G
403D-11G
403D-15G
404D-22G

*
*
*
*
*

7.7
11.5
16.5
20.2
29.7

8.5
12.6
18.1
22.2
32.7

86
86
86
87
89

0.8
0.8
0.8
0.8
0.8

1500 rev/min (9 kVA to 2500 kVA)


403D-11G
403D-15G
404D-22G
404D-22TG
1103A-33G
1103A-33TG1
1103A-33TG2
1104A-44TG1
1104A-44TG2

*
*
*
*
*
*
*
*
*

8.4
12.0
18.4
24.3
27.7
41.3
53.8
58.4
71.9

9.2
13.2
20.3
26.7
30.4
45.6
59.3
64.3
79.1

86
87
88
90
87
87
89
89
89

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

*
*
*
*
*
*
*
*
*

*
*
*
*
*
*
*
*
*

7.2
10.4
16.2
21.8
24.0
36.0
48.0
52.0
64.0

9.0
13.0
20.3
27.3
30.0
45.0
60.0
65.0
80.0

7.9
11.4
17.8
24.0
26.4
39.7
52.8
57.2
70.4

9.9
14.3
22.3
30.0
33.0
49.6
66.0
71.5
88.0

1104C-44TAG2

90.1

99.5

90

0.8

81.4

101.4

89.6

111.9

*
*
*
*
*
164
179
185
198
*
*
*
*
*
*
505
540
560
566
606
681
842
833
909
909
1005
1200
1178
1219
1347
1362
1500

83.0
91.0
121.0
129.3
158.4
180
198
204
217
305
349
396
435
522
565
632
679
710
715
767
861
1053
1055
1149
1148
1254
1267
1440
1558
1537
1684
1715
1875

91.5
100.0
133.5
143.0
175.5
199
217
224
239
349
392
434
478
574
609
695
760
782
787
844
947
1158
1166
1263
1263
1342
1395
1583
1684
1690
1894
1886
2083

90
90
90
93
93
92
92
92
92
92
92
92
92
92
92
95
94
95
95
95
95
95
95
95
95
96
95
95
96
96
96
96
96

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.6
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

*
*
*
*
*
151
165
170
182
*
*
*
*
*
*
480
512
532
538
576
647
800
791
864
864
955
1140
1120
1170
1280
1307
1440

*
*
*
*
*
189
205
213
228
*
*
*
*
*
*
600
640
665
672
720
809
1000
989
1079
1080
1194
1425
1400
1463
1600
1634
1800

74.5
82.0
109.0
120.0
147.3
166
182
188
200
280
320
364
400
480
520
600
640
675
679
728
818
1000
1002
1092
1091
1200
1204
1368
1480
1476
1600
1646
1800

93.0
102.5
136.0
150.0
184.1
208
228
235
250
350
400
455
500
600
650
750
800
843
849
911
1022
1250
1253
1364
1364
1500
1505
1710
1850
1844
2000
2058
2250

82.5
90.0
120.0
132.0
163.2
183
200
206
220
320
360
400
440
528
560
660
720
743
748
802
900
1100
1108
1200
1200
1280
1325
1504
1600
1622
1800
1811
2000

103.0
112.5
150.0
165.0
204.0
229
250
258
275
400
450
500
550
660
700
825
900
929
935
1002
1125
1375
1385
1500
1500
1600
1656
1880
2000
2028
2250
2263
2500

(Stage 2 compliant)

1006TG1A
1006TG2A
1006TAG
1006TAG2
1106C-E66TAG4
1306C-E87TAG3
1306C-E87TAG4
1306C-E87TAG5
1306C-E87TAG6
2206A-E13TAG2
2206A-E13TAG3
2506A-E15TAG1
2506A-E15TAG2
2806A-E18TAG1A
2806A-E18TAG2
4006-23TAG2A
4006-23TAG3A
4008TWG2
4008TAG
4008TAG1A
4008TAG2A
4012-46TAG0A
4012-46TWG2A
4012-46TWG3A
4012-46TAG1A
4012-46TWG4A
4012-46TAG2A
4012-46TAG3A
4016-61TRG1
4016TAG1A
4016-61TRG2
4016TAG2A
4016-61TRG3

Gas Power 1500 rev/min (307 kWe to 1000 kWe)


4006-23TRS1
4006-23TRS2
4008-30TRS1
4008-30TRS2
4012TESI
4016-61TRS1
4016-61TRS2

322
393
447
526
632
912
1042

95.4
95.4
95
95
95
96
96

1
1
1
1
1
1
1

307
375
425
500
600
875
1000

307
375
425
500
600
-

*Available on application Gross power


 Switchable engines must be requested at point of order, please consult with your local Perkins representative.
 Available as Electro Unit only
Notes:

All ratings are for guidance only, please refer to the specific engine technical data sheet for final powers.
Perkins conditions of sale apply.
Electrical output is based on typical generator efficiency and is for guidance only.
All ratings data based on operation under ISO 8528-1, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted by Perkins is 5%.
Baseload Power = Power available for continuous full load operation. An overload of 10% permitted for one hour in every twelve hours of operation.
Please Note: No overload is permitted on 4000 Series.
Prime Power = Power available at variable load in lieu of main power network (please refer to the engine Technical Data Sheets for engine load factors). An overload of 10% permitted for one hour in every twelve hours of
operation.
Standby Power = Power available at a variable load in the event of a main power network failure up to a maximum of 500 hours per year. No overload is permitted.




















Gen Set Power Selector Chart


Model offering for Unregulated Territories
2010 Issue 2

60Hz
Model

Typical
Generator Typical
Efficiency Power
Factor
Standby
%
kWm

Typical Generating
Set Output

Net Engine Output


Baseload
kWm

Prime
kWm

Baseload
kWe

kVA

Prime
kWe

kVA

Standby
kWe
kVA

1500/1800
rev/min
switchable

1800 rev/min (3.9 kWe to 1504 kWe)

402D-05G
403D-07G
403D-11G
403D-15G
404D-22G
404D-22TG
404D-22TAG
1103A-33G
1103A-33TG1
1103A-33TG2
1104A-44TG1
1104A-44TG2
1006TG1A
1006TG2A
1006TAG
1106C-E66TAG2
1106C-E66TAG3
1106C-E66TAG4
1106D-E66TAG2
1106D-E66TAG3
1106D-E66TAG4
1306C-E87TAG3
1306C-E87TAG4
2206A-E13TAG5
2206A-E13TAG6
2506A-E15TAG3
2506A-E15TAG4
2506C-E15TAG4#
2806A-E18TAG1A
2806A-E18TAG3
4006-23TAG2A
4008TWG2
4008TAG
4006-23TAG3A
4008TAG1
4008TAG2
4012-46TWG2A
4012-46TWG3A
4012-46TAG1A
4012-46TWG4A
4012-46TAG2A
4012-46TAG3A

*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
182
194
*
*
*
*
*
*
511
534
564
570
584
659
833
909
914
1009
1200

4.5
6.6
10.4
14.4
21.7
28.8
31.5
32.2
48.8
61.2
68.6
82.0
96.5
107.0
134.0
138.4
146.4
177.3
136.6
142.4
173.7
201
213
349
381
446
495
543
592
638
684
712
715
744
838
1055
1149
1153
1254
1272
1440

5.0
7.3
11.4
15.8
23.9
31.7
34.7
35.4
53.9
66.4
75.5
90.2
106.5
118.0
147.0
155.3
163.4
196.3
153.6
159.4
192.3
220
235
381
435
490
543
597
598
652
702
756
784
795
821
924
1166
1263
1267
1342
1399
1583

86
86
87
88
89
89
90
87
87
89
89
89
90
90
90
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
94
95
95
95
95
95
95
95
95
96
95
95

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
167
178
*
*
*
*
*
*
480
507
536
540
555
626
791
864
868
959
1140

*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
209
223
*
*
*
*
*
*
600
634
670
675
694
783
989
1079
1085
1199
1425

3.9
5.7
9.0
12.6
19.3
25.6
28.4
27.9
42.5
54.5
60.8
73.0
87.0
96.5
120.5
127.3
136.1
164.9
125.0
135.0
160.0
185
196
320
350
410
455
500
545
600
650
676
675
707
796
1002
1092
1095
1200
1208
1368

4.9
7.1
11.3
15.8
24.2
32.1
35.5
34.9
53.1
68.1
76.0
91.3
109.0
120.5
151.0
159.2
170.1
206.1
156.0
169.0
200.0
231
245
400
438
513
569
625
681
750
812
846
844
884
995
1253
1364
1369
1500
1510
1710

4.3
6.3
9.9
13.9
21.3
28.2
31.2
30.6
46.9
60.1
66.9
80.3
96.0
106.0
132.5
142.9
152.0
182.6
140.0
150.0
175.0
202
216
350
400
450
500
550
550
600
660
718
745
750
780
878
1108
1200
1204
1280
1329
1504

5.3
7.8
12.4
17.4
26.6
35.3
39.0
38.2
58.7
75.1
83.6
100.3
120.0
132.5
165.5
178.6
190.0
228.2
175.0
188.0
219.0
253
270
438
500
563
624
687
687
750
825
898
931
938
975
1097
1385
1500
1505
1600
1669
1880

95
95
96
96

0.8
0.8
0.8
0.8

466
520
872
1063

583
650
1091
1329

592
658
1100
1344

740
823
1375
1680

652
725
1212
1478

815
906
1515
1848

96

576

576
























1200 rev/min (592 kWe to 1478 kWe)


4008TAG1
4008TAG2
4016TAG
4016TAG2

491
547
908
1108

623
693
1146
1400

686
763
1263
1540

Gas Power 1200 rev/min (576 kWe)


4012TESI

600

*Available on application Gross power # Emergency Standby Power only


 Switchable engines must be requested at point of order, please consult with your local Perkins representative
 Available as Electro Unit only
Notes:

All ratings are for guidance only, please refer to the specific engine technical data sheet for final powers.
Perkins conditions of sale apply.
Electrical output is based on typical generator efficiency and is for guidance only.
All ratings data based on operation under ISO 8528-1, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted by Perkins is 5%.
Baseload Power = Power available for continuous full load operation. An overload of 10% permitted for one hour in every twelve hours of operation.
Please Note: No overload is permitted on 4000 Series.
Prime Power = Power available at variable load in lieu of main power network (please refer to the engine Technical Data Sheet for engine load factors). An overload of 10% permitted for one hour in every twelve hours of
operation.
Standby Power = Power available at a variable load in the event of a main power network failure up to a maximum of 500 hours per year. No overload is permitted.
Emergency Standby Power = Power available in the event of a main power network failure, up to maximum of 200 hours per year which may be run continuously. Load factor may be up to 70% of the Emergency Standby
Power rating. No overload is permitted.

Perkins Engines Company Limited


Peterborough PE1 5NA United Kingdom
Tel: +44 (0)1733 583000
Fax: +44 (0)1733 582240
www.perkins.com
All information in this document is substantially correct at time of printing and may be altered subsequently
Publication No.1542/01/10 produced in England Perkins Engines Company Limited 2008

Gen Set Power Selector Chart


EU2007 97/68/EC Certified Models
2010 Issue 2

50Hz
Model

Typical
Generator Typical
Net Engine Output
EU
Efficiency Power
Emissions
Level
Factor
Baseload Prime Standby
%
kWm
kWm
kWm

Typical Generating
Set Output

kWe

Baseload
kVA

kWe

Prime
kVA

Standby
kWe
kVA

1500/1800
rev/min
switchable

3000 rev/min (21.9 kVA to 36.4 kVA)


403D-15G
404D-22G

Stage 2
Stage 2

*
*

20.2
29.7

22.2
32.7

87
89

0.8
0.8

*
*

*
*

17.6
26.5

21.9
33.1

19.3
29.1

24.1
36.4

88
90
90
90
90
90
90
90
90
90
92
93
93
92
92
92
92
92
92
92
92
92

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

*
*
*
*
*
*
*
*
*
*
*
*
*
151
165
170
182
*
*
*
*
*

*
*
*
*
*
*
*
*
*
*
*
*
*
189
205
213
228
*
*
*
*
*

16.2
21.8
24.6
24.6
36.8
36.8
48.3
48.3
64.4
81.4
109.9
120.0
147.3
166
182
188
200
280
320
364
400
473

20.3
27.3
30.7
30.7
46.0
46.0
60.4
60.4
80.4
101.4
137.4
150.0
184.1
208
228
235
250
350
400
455
500
591

17.8
24.0
27.4
27.4
41.0
41.0
53.4
53.4
71.1
89.6
122.4
133.4
163.2
183
200
206
220
320
360
400
440
520

22.3
30.0
34.2
34.2
51.3
51.3
66.7
66.7
88.8
111.9
152.9
166.8
204.0
229
250
258
275
400
450
500
550
650

1500 rev/min (9 kVA to 650 kVA)


404D-22G
404D-22TG
1103C-33G2
1103C-33G3
1103C-33TG2
1103C-33TG3
1104C-44TG2
1104C-44TG3
1104C-44TAG1
1104C-44TAG2
1106C-E66TAG2
1106C-E66TAG3
1106C-E66TAG4
1306C-E87TAG3
1306C-E87TAG4
1306C-E87TAG5
1306C-E87TAG6
2206C-E13TAG2
2206C-E13TAG3
2506C-E15TAG1
2506C-E15TAG2
2806C-E18TAG1A

Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage
Stage

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

*
*
*
*
*
*
*
*
*
*
*
*
*
164
179
185
198
*
*
*
*
*

18.4
24.3
27.3
27.3
40.9
40.9
53.7
53.7
71.5
90.1
119.5
129.0
158.4
180
198
204
217
305
349
396
435
514

20.3
26.7
30.4
30.4
45.6
45.6
59.3
59.3
79.0
99.5
133.0
143.5
175.5
199
217
224
239
349
392
435
478
565



















*Available on application
 Switchable engines must be requested at point of order, please consult with your local Perkins representative.
Notes:

All ratings are for guidance only, please refer to the specific engine technical data sheet for final powers.
Perkins conditions of sale apply.
Electrical output is based on typical generator efficiency and is for guidance only.
All ratings data based on operation under ISO 8528-1, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted by Perkins is 5%.
Baseload Power = Power available for continuous full load operation. An overload of 10% permitted for one hour in every twelve hours of operation.
Prime Power = Power available at variable load in lieu of main power network (please refer to the engine Technical Data Sheets for engine load factors). An overload of 10% permitted for one hour in every twelve hours of operation.
Standby Power = Power available at a variable load in the event of a main power network failure up to a maximum of 500 hours per year. No overload is permitted.

Gen Set Power Selector Chart


EPA 40 CFR Part 89 Certified Models
2010 Issue 2

60Hz
Model

EPA
Emissions
Level

Typical
Generator Typical
Efficiency Power
Factor
Baseload Prime Standby
%
kWm
kWm
kWm

Typical Generating
Set Output

Net Engine Output

Baseload
kWe
kVA

Prime
kWe
kVA

Standby
kWe
kVA

1500/1800
rev/min
switchable

1800 rev/min (3.9 kWe to 600 kWe)


402D-05G
Tier 4
403D-07G
Tier 4
403D-11G
Tier 4
403D-15G
Tier 4
404D-22G
Interim Tier 4
404D-22TG
Interim Tier 4
404D-22TAG
Interim Tier 4
1104D-44TG1
Tier 3
1104D-E44TG1
Tier 3
1104D-E44TAG1
Tier 3
1104D-E44TAG2
Tier 3
1106D-E66TAG2
Tier 3
1106D-E66TAG3
Tier 3
1106D-E66TAG4
Tier 3
2206D-E13TAG2
Tier 3
2206D-E13TAG3
Tier 3
2506D-E15TAG1
Tier 3
2506C-E15TAG3
Tier 2
2506C-E15TAG4#
Tier 2
2806C-E18TAG3
Tier 2

*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*

4.5
6.6
10.4
14.4
21.7
28.8
31.5
57.0
65.2
82.0
100.0
136.6
142.4
173.7
349
381
435
495
592

5.0
7.3
11.4
15.8
23.9
31.7
34.7
63.0
71.8
90.8
111.0
153.6
159.4
192.3
381
435
490
543
597
652

86
86
87
88
89
89
90
90
90
90
90
92
92
92
92
92
92
92
92
92

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*

*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*

3.9
5.7
9.0
12.6
19.3
25.6
28.4
51.3
58.7
73.8
90.0
125.0
135.0
160.0
320
350
400
455
545

4.9
7.1
11.3
15.8
24.2
32.1
35.5
64.1
73.4
92.0
113.0
156.0
169.0
200.0
400
438
500
569
681

4.3
6.3
9.9
13.9
21.3
28.2
31.2
56.7
64.6
81.7
100.0
140.0
150.0
175.0
350
400
450
500
550
600

5.3
7.8
12.4
17.4
26.6
35.3
39.0
70.9
80.8
102.0
125.0
175.0
188.0
219.0
438
500
563
625
687
750

86
86

0.8
0.8

*
*

*
*

7.6
11.3

9.5
14.1

8.3
12.4

10.4
15.5





3600 rev/min (7.6 kWe to 12.4 kWe)


402D-05G
403D-07G

Tier 4
Tier 4

*
*

8.8
13.1

9.7
14.4

*Available on application # Emergency Standby Power only


 Switchable engines must be requested at point of order, please consult with your local Perkins representative.
 Available as Electro Unit only
Notes:

All ratings are for guidance only, please refer to the specific engine technical data sheet for final powers.
Perkins conditions of sale apply.
Electrical output is based on typical generator efficiency and is for guidance only.
All ratings data based on operation under ISO 8528-1, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted by Perkins is 5%.
Baseload Power = Power available for continuous full load operation. An overload of 10% permitted for one hour in every twelve hours of operation.
Prime Power = Power available at variable load in lieu of main power network (Please refer to the engine Technical Data Sheets for engine load factors). An overload of 10% permitted for one hour in every twelve hours of operation.
Standby Power = Power available at a variable load in the event of a main power network failure up to a maximum of 500 hours per year. No overload is permitted.
Emergency Standby Power = Power available in the event of a main power network failure, up to maximum of 200 hours per year which may be run continuously. Load factor may be up to 70% of the Emergency Standby Power
rating. No overload is permitted.

Perkins Engines Company Limited


Peterborough PE1 5NA United Kingdom
Tel: +44 (0)1733 583000
Fax: +44 (0)1733 582240
www.perkins.com
All information in this document is substantially correct at time of printing and may be altered subsequently
Publication No.1858/01/10 produced in England Perkins Engines Company Limited 2008