Professional Documents
Culture Documents
SIHI P
umps
Pumps
www.sterlingamericas.com
SIHI PUMPS
PERFORMANCE AND RELIABILITY
Vacuum
More than 29 Hg Vacuum attainable with a single pump unit.
Higher Vacuum
Achievable by incorporating other SIHI Products.
Operational Safety
Provided by the low temperature rise of the Liquid Ring
Principle ensuring the safest compression of hazardous
and explosive vapors.
Construction Flexibility
Models available in a variety of shaft seals and materials
including Cast Iron, Bronze, Stainless Steels, Hastelloys
and Titanium.
In a round pump body (A), a shaft mounted impeller (B) is positioned at a point eccentric to the centerline of the pump body. The centrifugal action of the rotating impeller
forces the service liquid introduced via channel (D) towards the periphery of the pump
body forming the liquid ring (C).
When pumping action is achieved, the gas mixture being handled is introduced to the
impeller through the suction port (H), in the intermediate plate (E), causing a vacuum at
the pump suction. The gas mixture fills the impeller cavity between the inside diameter of
the liquid ring and the root of the impeller blade. As the impeller rotates,
the impeller blade immersion
in the liquid ring increases
A
J
Pump
Pump Suction H
reducing the volume
Discharge
(Gas Mixture)
between the liquid
(Gas & Liquid)
ring and the root
of the impeller
blade. The result is the compression of the
Service
Liquid
gas mixture
Inlet
until it reaches
the discharge
port (J), located
in the intermediate
plate (K). The gas
mixture exits through the
D E
B C
K
discharge port.
During the compression cycle heat is
being imparted to the liquid ring. In order to maintain a temperature below the
vapor point of the service liquid, cooling
must be applied. Cooling is achieved by
continuously adding a cool supply of
service liquid to the liquid ring. The
amount of service liquid added is equal
to that discharged through the discharge
port (J) together with the compressed
gas mixture. The gas mixture and service
liquid is eventually passed through the
pump discharge for separation.
= Gas Mixture
= Service Liquid
= Gas & Liquid
ONCE THROUGH
Used where service liquid is plentiful and
contamination is not a problem.
System Vent
Pump Suction
Benefits
Simplicity
Separator
Inlet
Check Valve
To drain
Compound
Gauge
PI
Isolating
Valve
S
Service Liquid
Flow Regulating
Y - Strainer Isolating Valve
Valve
Solenoid Valve
(normally closed)
PARTIAL RECIRCULATION
Used where service liquid is available and
contamination problems are minimal.
System Vent
Pump Suction
Separator
Inlet
Check Valve
Benefits
Overflow
Simplicity
Compound
Gauge
M
PI
Isolating
Valve
Regulating
Valve
Partial
Recirculating
Piping
Service Liquid
Flow Regulating
Valve
TOTAL RECIRCULATION
Used where gases and liquids are toxic
or hazardous, and when environmental
contamination is a concern.
Benefits
Service liquid contained and
separated from nonhazardous
coolant systems
Low service liquid usage
Allows recovery of condensable
inlet gases
System Vent
Pump Suction
Separator
Inlet
Check Valve
Isolating
Valve
Compound
Gauge
Gauge
Glass
Overflow
LI
PI
Flow
Regulating
Valve
Heat Exchanger
8
21.92
557
CFM
14.3
12
17.92
455
CFM
14.8
16
13.92
354
CFM
14.7
20
9.92
252
CFM
13.8
24
5.92
150
CFM
11.3
26
3.92
100
CFM
-
26.4 Average
Service
3.52
Liquid
Flow
89
CFM USGPM
1.0
LPH 20105
(1 x 1)
3500
23.5
27.0
29.0
29.5
28.0
22.0
1.0
LPH 20107
(1 x 1)
3500
29.5
32.0
33.5
34.0
31.7
23.0
1.1
LPH 3404
(1 x 1)
2
3
20
40
20
40
19
40
17
40
10
40
32
3
3
LPH 3408
(1 x 1)
1150
1750
1150
1750
3
5
40
75
40
75
38
75
34
75
23
74
65
3
3
LPH 40412
(1 x 1)
1750
7.5
118
118
118
118
117
102
60
LPH 40517
(2 x 2)
1750
10
164
167
167
167
163
147
105
LPH 50518
(2 x 2)
1150
1750
*7.5
15
152
248
153
250
155
250
151
248
142
240
118
217
82
184
70
170
8
8
LPH 50523
(2 x 2)
1150
1750
10
20
182
315
186
325
187
330
184
327
173
318
142
288
90
250
70
235
7
7
LPH 60520
(4 x 4)
1150
1450
1750
15
20
25
225
295
365
232
300
365
235
305
365
233
305
362
218
300
352
175
276
322
120
225
267
175
220
7
7
7
LPH 60527
(4 x 4)
1150
1450
1750
20
25
40
283
395
470
290
395
470
295
395
470
295
395
470
290
390
456
255
350
415
150
285
350
225
300
8
8
8
LPH 70123
(4 x 4)
880
975
1030
1150
30
*30
40
*40
455
502
540
600
455
502
540
600
455
502
540
600
455
502
540
600
440
483
520
580
375
410
440
485
285
330
340
380
259
295
300
305
10
10
10
10
LPH 70530
(5 x 5)
880
975
1030
1150
40
*40
50
60
590
685
735
825
590
685
735
820
590
685
730
812
590
675
720
795
575
655
690
760
535
590
625
685
450
485
520
545
365
410
420
430
15
15
15
15
LPH 70540
(5 x 5)
880
975
1030
1150
50
60
60
75
850
913
985
1120
850
913
985
1120
850
913
985
1120
850
913
985
1120
830
910
980
1095
770
845
910
1000
630
700
770
825
500
600
660
700
17
17
17
17
LPH 80540
(8 x 8)
700
735
880
75
75
100
1153
1235
1437
1188
1258
1470
1200
1275
1475
1190
1255
1466
1137
1220
1425
1025
1108
1320
918
980
1168
875
940
1120
27
27
27
LPH 80553
(8 x 8)
700
735
880
100
100
125
1490
1600
1890
1532
1635
1933
1560
1655
1955
1565
1650
1950
1550
1625
1905
1425
1525
1787
1210
1305
1555
1150
1250
1495
31
31
31
LPH 80557
(8 x 8)
575
680
735
75
100
125
1610
1960
2130
1610
1950
2125
1600
1935
2115
1560
1890
2080
1500
1820
2015
1350
1700
1880
1100
1410
1580
950
1140
1440
24
24
24
LPH 90554
(10 x 10)
465
600
700
100
125
150
1610
2150
2470
1610
2150
2470
1590
2150
2470
1560
2120
2440
1500
2060
2380
1354
1915
2200
1120
1670
1880
1000
1590
1765
44
44
44
LPH 90567
(10 x 10)
465
600
700
125
150
200
1830
2650
2980
1830
2650
2980
1825
2650
2980
1810
2640
2975
1760
2590
2930
1580
2420
2780
1260
2150
2460
1145
2060
2295
53
53
53
LPH 10054
(12 x 12)
410
490
565
*150
*200
*250
3000
3650
4300
3000
3720
4300
3000
3770
4300
2970
3750
4280
2900
3660
4200
2620
3445
3930
2000
3000
3500
1678
2886
3357
74
74
74
LPH 11055
(14 x 14)
335
415
475
250
*300
400
4240
5600
6300
4240
5600
6300
4240
5600
6300
4230
5550
6260
4130
5480
6150
3710
5064
5770
2600
4200
4900
2060
3828
4416
108
108
108
* Horsepower given is for motors with 1.15 service factor only. Use next larger size with 1.0 service factor motors.
This data represents average values for pumps in standard material of construction discharging against atmospheric pressure at sea level. Capacity in cubic feet per minute at inlet pressure for air at 20C
(68F) and using 15C (59F) water as the service liquid. When handling 100% saturated air see performance data on following pages.
4
25.92
658
CFM
13.5
27.0
12
20
22.5
25
27.5
17.92 9.92 7.42 4.92 2.42
455 252 188
125 61.5
CFM CFM CFM CFM CFM
14.5 14.9 14.9 14.5 11.5
30.0 31.0 31.0 31.0 26.5
28
1.92
48.8
CFM
11.0
23.0
LPH 25003
LPH 25007
(1 x 1)
LPH 3704
(1 x 1)
1150
1750
3
5
25
37
25
37
25
37
25
42
25
42
21
33
18
29
20
17
4
4
LPH 3708
(1 x 1)
1150
1750
5
7.5
42
70
42
70
44
70
44
75
44
74
43
62
40
55
41
30
5
5
LPH 45312
(1 x 1)
1150
1750
5
7.5
54
88
54
90
57
102
61
110
66
112
68
102
64
95
48
70
42
61
3
3
LPH 45317
(1 x 1)
1150
1750
5
10
60
105
67
105
74
150
80
155
87
150
82
136
78
125
58
90
48
73
4
4
LPH 55312
(2 x 2)
1150
1750
7.5
*15
106
141
106
141
118
177
123
196
124
199
119
186
110
173
82
130
71
117
10
10
LPH 55316
(2 x 2)
1150
1750
10
20
112
200
112
200
135
228
145
244
148
248
130
230
118
210
87
149
76
122
11
11
LPH 55320
(2 x 2)
1150
1750
15
25
117
206
117
206
147
247
157
302
160
315
143
290
131
265
106
183
82
148
13
13
LPH 65320
(2 x 2)
1150
1450
1750
15
25
30
194
265
324
194
267
325
200
285
330
210
285
340
220
290
345
220
290
320
215
270
305
175
210
235
160
190
210
9
9
9
LPH 65327
(2 x 2)
1150
1450
1750
20
30
40
235
320
375
232
320
375
245
330
385
255
340
395
280
350
410
280
350
395
260
335
360
200
240
255
180
200
210
9
9
9
LPH 75320
(4 x 4)
880
975
1030
1150
40
40
*40
*50
370
410
425
445
385
415
430
460
420
470
485
515
445
500
515
545
460
515
535
570
430
480
495
530
405
455
470
490
315
365
370
375
295
335
335
340
19
19
19
19
LPH 75330
(4 x 4)
880
975
1030
1150
50
50
60
75
510
565
580
595
535
590
620
655
610
670
700
745
635
700
730
770
670
740
770
830
600
675
695
730
535
615
630
665
400
455
485
470
380
390
395
400
20
20
20
20
LPH 75340
(4 x 4)
880
975
1030
1150
50
60
*60
100
665
735
760
800
665
740
770
820
700
800
835
890
755
850
885
940
850
930
955
995
810
905
925
955
740
840
860
890
510
600
630
650
460
510
525
525
21
21
21
21
LPH 85340
(6 x 6)
700
735
880
100
100
125
695
765
840
38
38
38
LPH 85353
(6 x 6)
700
735
880
*100
125
150
980
1030
1130
50
50
50
LPH 95354
(8 x 8)
465
600
700
125
*150
*200
1030
1180
1295
71
71
71
LPH 95367
(8 x 8)
465
600
700
125
200
250
1295
1530
1650
76
76
76
LPH 10534
(8 x 8)
400
490
590
200
*250
350
1975
2260
2475
108
108
108
LPH 11535
(10 x 10)
335
415
470
*250
*350
450
2885
3240
3500
147
147
147
(1 x 1)
* Horsepower given is for motors with 1.15 service factor only. Use next larger size with 1.0 service factor motors.
This data represents average values for pumps in standard material of construction discharging against atmospheric pressure at sea level. Capacity in cubic feet per minute at inlet pressure for air at 20C
(68F) and using 15C (59F) water as the service liquid. When handling 100 % saturated air see performance data on following pages.
IF REQUIREMENTS ARE IN THE DARK BLUE AREA, A MORE EFFICIENT SELECTION CAN BE MADE FROM PUMPS LISTED ON PRECEDING PAGE.
8
21.92
557
CFM
12
17.92
455
CFM
16
13.92
354
CFM
20
9.92
252
CFM
24
5.92
150
CFM
26
3.92
100
CFM
26.4 Average
Service
3.52
Liquid
Flow
89
CFM USGPM
LPH 20103 (1 x 1)
3500
*1.5
13.8
14.6
15.2
15.2
14.4
12.2
1.0
LPH 20105 (1 x 1)
3500
23.9
27.6
29.7
30.5
29.3
23.7
1.0
LPH 20107 (1 x 1)
3500
30.0
32.7
34.3
35.1
33.1
24.8
1.1
LPH 3404
(1 x 1)
1150
1750
2
3
20
41
20
41
19
41
18
41
10
42
35
3
3
LPH 3408
(1 x 1)
1150
1750
3
5
41
76
41
77
39
77
35
77
24
77
70
3
3
LPH 40412 (1 x 1)
1750
7.5
120
120
121
122
122
110
67
LPH 40517
1750
10
167
170
171
172
170
159
118
LPH 50518 (2 x 2)
1150
1750
*7.5
15
155
252
156
255
159
256
156
256
148
251
127
234
92
207
80
194
8
8
LPH 50523 (2 x 2)
1150
1750
10
20
185
321
190
332
192
338
190
338
181
333
153
311
101
281
80
268
7
7
LPH 60520
(4 x 4)
1150
1450
1750
15
20
25
229
300
371
237
306
373
241
313
374
241
315
374
228
314
368
189
298
347
135
253
300
199
251
7
7
7
LPH 60527
(4 x 4)
1150
1450
1750
20
25
40
288
402
478
296
403
480
302
405
482
305
408
485
303
408
477
275
377
448
168
320
393
256
342
8
8
8
LPH 70123
(4 x 4)
880
975
1030
1150
30
*30
40
*40
463
511
550
611
464
512
551
612
466
515
554
615
470
518
557
619
460
505
544
606
404
442
474
523
320
370
382
427
295
336
342
348
10
10
10
10
LPH 70530
(5 x 5)
880
975
1030
1150
40
*40
50
60
600
697
748
840
602
699
750
837
605
702
748
832
609
697
743
821
601
685
721
795
577
636
674
739
505
544
584
612
416
467
479
490
15
15
15
15
LPH 70540
(5 x 5)
880
975
1030
1150
50
60
60
75
865
929
1002
1140
868
932
1005
1143
871
936
1010
1148
877
942
1017
1156
868
951
1025
1145
830
911
981
1078
707
786
864
926
570
684
752
798
17
17
17
17
LPH 80540
(8 x 8)
700
735
880
75
75
100
1173
1257
1462
1213
1284
1500
1230
1307
1512
1228
1296
1513
1189
1276
1490
1105
1195
1423
1030
1100
1311
997
1072
1277
27
27
27
LPH 80553
(8 x 8)
700
735
880
100
100
125
1516
1628
1923
1564
1669
1973
1599
1697
2004
1616
1703
2013
1621
1699
1992
1537
1645
1927
1358
1465
1745
1311
1425
1704
31
31
31
LPH 80557
(8 x 8)
575
680
735
75
100
125
1638
1994
2167
1643
1990
2169
1640
1984
2168
1610
1951
2147
1568
1903
2107
1456
1833
2027
1235
1583
1774
1083
1299
1641
24
24
24
LPH 90554
(10 x 10)
465
600
700
100
125
150
1638
2188
2513
1643
2195
2521
1630
2204
2532
1610
2188
2519
1568
2154
2489
1460
2065
2372
1257
1875
2110
1140
1812
2012
44
44
44
LPH 90567
(10 x 10)
465
600
700
125
150
200
1862
2697
3032
1868
2705
3042
1871
2717
3055
1868
2725
3071
1840
2708
3064
1704
2610
2998
1414
2413
2761
1305
2348
2616
53
53
53
LPH 10054
(12 x 12)
410
490
565
*150
*200
*250
3053
3714
4376
3062
3797
4389
3076
3865
4408
3066
3871
4418
3032
3827
4392
2825
3715
4238
2245
3368
3929
1913
3290
3827
74
74
74
LPH 11055
(14 x 14)
335
415
475
250
*300
400
4315
5699
6411
4328
5716
6430
4347
5741
6459
4367
5729
6462
4318
5730
6430
4001
5461
6222
2919
4715
5500
2348
4364
5034
108
108
108
(2 x 2)
* Horsepower given is for motors with 1.15 service factor only. Use next larger size with 1.0 service factor motors.
This data represents average values for pumps in standard material of construction discharging against atmospheric pressure at sea level. Capacity in cubic feet per minute at inlet pressure for air with 100%
saturation at 20C (68F) and using 15C (59F) water as the service liquid. When handling saturated air at higher temperatures the capacity of vacuum pumps will increase substantially; performance is
available upon application.
LPH 25003
(1 x 1)
LPH 25007
(1 x 1)
LPH 3704
(1 x 1)
LPH 3708
(1 x 1)
LPH 45312
(1 x 1)
LPH 45317
(1 x 1)
LPH 55312
(2 x 2)
LPH 55316
(2 x 2)
LPH 55320
(2 x 2)
LPH 65320
(2 x 2)
LPH 65327
(2 x 2)
LPH 75320
(4 x 4)
LPH 75330
(4 x 4)
LPH 75340
(4 x 4)
LPH 85340
1150
1750
1150
1750
22.5
25
27.5
7.42 4.92 2.42
188
125 61.5
CFM CFM CFM
15.8 15.9 14.0
28
1.92
48.8
CFM
14.2
28.7
1.22
31
CFM
11.1
28.9 Average
Service
0.98
Liquid
25
Flow
CFM USGPM
1.4
27.5
30.8
32.4
32.9
34.0
32.3
29.7
19.0
1.4
3
5
5
7.5
25
37
43
71
26
37
43
72
26
38
46
73
27
44
47
80
27
46
48
81
25
40
52
76
23
37
52
71
32
65
32
56
4
4
5
5
1150
1750
5
7.5
55
90
55
92
60
107
65
117
72
123
83
124
83
123
76
111
78
114
3
3
1150
1750
5
10
61
107
69
108
77
157
85
165
95
164
100
166
101
162
92
142
89
136
4
4
1150
1750
7.5
*15
108
143
109
145
123
185
131
208
136
218
145
227
142
224
130
205
132
218
10
10
1150
1750
10
20
114
204
115
205
141
238
154
259
162
272
158
280
153
271
137
235
141
227
11
11
1150
1750
15
25
119
210
120
211
154
258
167
321
175
345
174
353
169
343
167
289
153
275
13
13
1150
1450
1750
15
25
30
197
270
330
199
274
333
209
298
345
223
303
361
241
318
378
268
353
390
278
349
394
276
332
371
298
354
391
9
9
9
1150
1450
1750
20
30
40
239
326
382
238
328
384
256
345
403
271
361
419
307
383
449
341
426
481
336
433
465
316
379
403
335
372
391
9
9
9
880
975
1030
1150
40
40
*40
*50
377
417
432
453
395
425
441
472
439
491
507
538
472
531
547
579
504
564
586
624
524
585
603
646
524
588
608
633
498
577
585
592
549
624
624
633
19
19
19
19
880
975
1030
1150
50
50
60
75
519
575
590
605
548
605
636
672
638
701
732
779
674
743
775
818
734
811
844
909
731
822
847
889
692
795
814
860
632
719
766
743
707
726
735
745
20
20
20
20
880
975
1030
1150
50
60
*60
100
677
748
773
814
682
759
789
841
732
836
873
931
856
949
977
977
21
21
21
21
(6 x 6)
700
735
880
100
100
125
1294
1424
1564
38
38
38
LPH 85353
(6 x 6)
700
735
880
*100
125
150
1824
1917
2103
50
50
50
LPH 95354
(8 x 8)
465
600
700
125
*150
*200
1917
2196
2411
71
71
71
LPH 95367
(8 x 8)
465
600
700
125
200
250
2411
2848
3071
76
76
76
LPH 10534
(8 x 8)
400
490
590
200
*250
350
3676
4207
4607
108
108
108
LPH 11535
(10 x 10)
335
415
470
*250
*350
450
5370
6031
6515
147
147
147
* Horsepower given is for motors with 1.15 service factor only. Use next larger size with 1.0 service factor motors.
This data represents average values for pumps in standard material of construction discharging against atmospheric pressure at sea level. Capacity in cubic feet per minute at inlet pressure for air with
100% saturation at 20C (68F) and using 15C (59F) water as the service liquid. When handling saturated air at higher temperatures the capacity of vacuum pumps will increase substantially;
performance is available upon application.
IF REQUIREMENTS ARE IN THE DARK BLUE AREA, A MORE EFFICIENT SELECTION CAN BE MADE FROM PUMPS LISTED ON PRECEDING PAGE.
ENGINEERED PACKAGES
Contact
Warranty
SIHI Pumps has competent engineering teams backed by more than sixty years
experience to design and build packages custom suited to your requirements.
TYPICAL APPLICATIONS
Drying
Distillation
Evaporation Crystallization
Vapor Recovery
Deaeration
Sterilization
Filtration
Evisceration
Impregnation
Extrusion
Condensor Exhaust
Vacuum Conveyance
Priming
Vacuum Packaging
Central Vacuum Systems