Presentation, description

Modicon Premium automation platform


Modbus serial link

Presentation

1
Magelis XBT Gp Modicon M340

Altivar 71

2 3 4 5 6
3

Modbus

Modicon Premium TSX Micro

Twido

Preventa XPS MC

Advantys OTB

The Modbus bus is used for master/slave architectures (it is necessary, however, to check that the Modbus services used by the application are implemented on the devices concerned) The bus comprises one master station and several slave stations Only the master station can initiate the exchange (direct communication between slave stations is not possible) Two exchange mechanisms are possible: b Question/answer, where the requests from the master are addressed to a given slave The master then waits for the response from the slave which has been interrogated b Broadcasting, the master broadcasts a message to all the slave stations on the bus These stations execute the order without transmitting a response

Description
The Modicon TSX Micro/Premium PLCs or Atrium slot-PLCs offer various Modbus bus connection possibilities Built-in link to the TSX Micro or to the Premium module TSX SCY p1601 1 Via integrated port on the TSX Micro processor The TER port (8-way mini DIN) has Modbus RTU master/slave (1) protocol 2 Via integrated port on the TSX SCY 11601/21601 module for Premium PLCs This module has an isolated Half-duplex RS 485 serial link channel (25-way SUB-D connector) with multiprotocol (including Modbus); (for the TSX SCY 11601 module, only the Modbus protocol is supported)

TSX Micro

7
4

6 5

8
2

TSX SCP 11p multiprotocol PCMCIA cards 3 A slot on the TSX Micro/Premium processors, the Atrium slot-PLC and the TSX SCY 21601 module(2) exists for the multiprotocol TSX SCP11p cards, including Modbus, featuring: 4 A protective cover 5 A removable cover with fixing screws (to access a 20-way miniature connector). 6 Two LEDs: - ERR lamp: card or link fault, - COM lamp: data transmission or reception To be ordered separately: TSX SCP/SCY cordset
6 4 5

9 10
References: pages 5/103

3 Premium TSX SCY 21601 TSX SCY 11601

___________________________________________________________________________ (1) Modbus RTU slave Protocol with TSX 37 05/08. (2) This slot is also designed for Fipway TSX FPP 20 PCMCIA network cards.

5/100

Characteristics

Modicon Premium automation platform


Modbus serial link

Characteristics
Physical Interface TSX Micro terminal port Non-isolated RS 485 TSX 37 05/08 TSX 37 10/21/22 Heterogeneous industrial bus Slave Master/slave Asynchronous in baseband RTU 12142 Kbit/s Double shielded twisted pair PCMCIA card Isolated RS 485 (1) 20 mA CL TSX SCY integrated port for Premium Isolated RS 485 Non-isolated TSX TSX RS 232 SCY 11601 SCY 21601

1 2 3 4 5 6 7 8 9 10

Structure Transmission

Type Method of access Mode Frame Data rate Medium

Master/slave Type RTU/ASCII 06192 Kbit/s for TSX SCP 111 12 192 Kbit/s for TSX SCP 112/114 Double Quintuple shielded shielded twisted pair, twisted pair doubled 2 16 max (point-to-point) 98 1,300 m excluding tap links 15 m max 1001,000 m 15 m max according to rate

12192 Kbit/s Double shielded twisted pair

Configuration

Number of devices Max number of link addresses Length of bus Tap links

28 max in RS 485 Point-to-point in RS 422 98 248 10 m max non isolated link 1,300 m max on isolated link (2)

32 248 98

1,300 m excluding 15 m

Services

Requests Security Monitoring

Bits: 1,920 bits per request Words: 120 words per request One CRC 16 check parameter on each frame No flow control Diagnostic counters, event counters

Modbus functions available on Premium/TSX Micro PLCs or on Atrium slot-PLC

Code 01 02 03 04 05 06 07 08 0B 0C 0F 10 11

Modbus slave Read n output bits Read n input bits Read n output words Read n input words Write 1 output bit Write 1 output word Exceptional read status Diagnostic Event counter Event connection Write n output bits Write n output words Identification

Modbus master Read bits Read input bits (3) Read words Read input words (3) Write 1 bit or n bits Write 1 word or n words Exceptional read status Diagnostic Event counter Event connection Slave identification Other requests accessible via SEND_REQ generic function blocks

(1) Point-to-point RS 422 compatible connection. (2) For an isolated link, you must use the TWD XCA ISO Modbus TAP isolation. (3) Requests not available on TSX 37 10/21/22 terminal port.

References: pages 5/103

5/101

References

Modicon Premium automation platform


Modbus serial link

Modbus bus connection elements

1 2
TSX Micro TSX SCP 11p

Description TSX Micro PLC integrated link (TER port) Communication module for Premium/Atrium

Protocol

Physical layer

Reference

Weight kg

Modbus (RTU) Non-isolated RS 485 Uni-Telway character mode Modbus Character mode Uni-Telway Modbus - 1 RS 485 isolated integrated channel (channel 0), (197 slaves) - 1 slot for PCMCIA card (channel 1) (1) 1 RS 485 isolated integrated channel (channel 0), 12192 Kbit/s (1 to 247 slaves) RS 485 (RS 422 compatible) 12192 Kbit/s RS 232 (9 signals) 06192 Kbit/ 20 mA CL 12192 Kbit/s

Consult our catalog wwwschneider-electriccom

TSX SCY 21601 TSX SCY 11601

0360 0340

3 4 5
TSX SCA 50

PCMCIA cards Modbus for Premium Character mode processor, Atrium Uni-Telway slot-PLC, PLC TSX 37 21/22 or TSX SCY 21601 module

TSX SCP 114 TSX SCP 111 TSX SCP 112

0105 0105 0105

TSX SCY 21601

TSX SCY 11601

Modbus connection accessories

Description

Use Bus tap link and extension, line termination adaptation

Reference TSX SCA 50

Passive junction box 2 channel passive subscriber socket (2 or 4 wire) (2)

Weight kg 0520

Tap link of 2 devices with 2 wires TSX SCA 62 Tap link of 1 master device and/or 1 slave device with 4 wires Fitted with 2 female 15-pin SUB-D connectors TWD XCA ISO

0570

6 7 8
TWD XCA ISO TSX SCA 62

RS 485 TAP isolation RS 485 line isolation (1) Line end adapter (RC 120 W, 1nF) Screw terminal for trunk cable and 2 x RJ45 for derivation c 24 V supply (screw terminal block) Mounting on 35 mm 5 TER terminal port cable connector Bus tap link cable (2 or 4-wire) Isolation of Modbus signals Line termination adaptation Supplied with cable (length 1 m) fitted with a mini-DIN connector (TER port) Connection of an RS 232 device as RS 485 Isolation of signals and line termination adaptation

0,100

TSX P ACC 01

0690

Active adapter RS 232/RS 485

TSX SCA 72

0520

Line terminators Sold in lot of 2

2/4-wire cabling Can be connected to the front panel of the TSX SCA 62 subscriber socket

TSX SCA 10

0030

9 10
Description: page 5/100 Characteristics: page 5/101

(1) PCMCIA slot for 1 TSX SCP 111/112/114 or TSX FPP 20 card. (2) Line isolation recommended for the length > 20 m.

5/102

References (continued)

Modicon Premium automation platform


Modbus serial link

Modbus connection cables


Description RS 485 double shielded twisted pair trunk cables Use From Modbus Bus Length To 100 m 200 m 500 m Reference TSX CSA 100 TSX CSA 200 TSX CSA 500 TSX SCP CM 4030 TSX SCP CM 4530 TSX SCP CX 4030 Weight kg 5680 10920 30000 0160 0,180 0160

1 2 3 4 5 6 7 8 9 10

Cables for isolated RS 422/485 tap link

TSX SCP 114 card

TSX SCA 50 housing 3m 2 wires (1) TSX SCA 62 subscriber 3 m socket, 2/4 wires Modbus standard 3m device, 4 wires (1) (point-to-point) TSX SCA 50 housing, 3 m 2 wires (1) TSX SCA 62 subscriber 3 m socket, 2 wires

Built-in channel (channel 0) Premium module TSX SCY 11601, TSX SCY 21601

TSX SCY CM 6030 TSX SCY CM 6530

0160 0160

RS 485 cordsets

Twido and TSX Micro terminal port (mini-DIN connector)

TWD XCA ISO TAP isolation (2 x RJ45 connectors)

0,3 m 1m 3m

TWD XCA RJ003 TWD XCA RJ010 TWD XCA RJ030

0040 0090 0160

RS 232 tap link cordsets

TSX SCP 111 card

Communication device 3 m (Modem, converter, etc) (DCE) (2) Terminal device 3m with point-to-point 10 m (DTE) (2) Multidrop Modbus (1) 3m

TSX SCP CC 1030 TSX SCP CD 1030 TSX SCP CD 1100

0190 0190 0620

Corset for tap link 20 mA CL Other connecting cables

TSX SCP 112 card

TSX SCP CX 2030

0160

See page 5/110

(1) End of cordset with free wires. (2) End of cordset fitted with a male 25-pin SUB-D connector.

Description: page 5/100

Characteristics: page 5/101

5/103

Presentation, characteristics

Modicon Premium automation platform


Uni-Telway serial link

Presentation

1
Premium

The Uni-Telway bus is a standard means of communication between control system components (PLCs, MMI terminals, supervisors, variable speed drives, numerical controllers, weighing equipment, etc) It is suitable for architectures designed to manage control and monitoring devices via a PLC, or architectures used for MMI (supervision, etc) The Uni-Telway bus requires a master station which manages the allocation of bus access rights to the various connected stations (known as slave stations)
Uni-Telway

2
Magelis XBT Gp

3
Altivar 71/61

4 5 6 7 8 9 10

TSX Micro

Characteristics
Physical interface Structure Type Link Method of access Mode Data rate Medium Number of devices Number of connection addresses Length of bus Tap links Service Uni-TE RS 485 non isolated Premium RS 485 isolated module terminal port integrated port (1) (TER/AUX) Heterogeneous industrial bus Multidrop Master/Slave principle Asynchronous transmission in baseband 12192 Kbit/s Shielded double twisted pair 5 max 8 max 10 m max, 1,000 m with TSX P ACC 01 28 max 16 max 96 max(1 device can occupy several datalink addresses) 1,000 m max excluding tap links 20 m 20 m 1300 m max, excluding tap links 15 m Isolated RS 485/RS 422 PCMCIA card 20 mA CL PCMCIA card Non-isolated RS 232 PCMCIA card

Point-to-point

Transmission

03192 Kbit/s 2

Configuration

15 m (unlimited via modem)

Point-to-point requests with confirmation (question/response), of up to 240 bytes (2) initiated by any connected device Unsolicited point-to-point data, without confirmation, of up to 240 bytes(2) initiated by any connected device Broadcast messages of up to 240 bytes (2) initiated by the master device Transparent communication, via the master, with any device in an X-Way architecture Diagnostics, debugging, adjustment and programming of PLCs Check character on each frame, acknowledgement and, if required, repetition of messages ensure security of transmission Bus status table, transmission error counters and device status can be accessed by program in each device Status of the bus and devices connected from the master PLC accessible using Unity Pro or PL7 software (1) TSX SCY 21601 single format module. (2) Limited to 128 bytes with TSX Micro/Premium PLC terminal port.

Other functions Security Monitoring

Connections: page 5/106

References: page 5/107

5/104

Characteristics (continued), description

Modicon Premium automation platform


Uni-Telway serial link

Performances
BCT (ms)
400

1
300

The Uni-Telway bus cycle time depends on: b The number of devices polled (datalink addresses) b The data rate b The turnaround time of each device b The number, length and type of messages BCT = Bus Cycle Time, is the interval between two polls from the same device The curves opposite give the Uni-Telway cycle time as a function of the number of slaves operating at 96 Kbit/s or 192 Kbit/s, with a typical turnaround time of 5 ms per device (excluding messages) The following table shows the time to be added (in ms) to obtain the true BCT value as a function of the traffic (N = Number of usable characters):
Exchanges Master to slave Time (ms) at 96 Kbit/s 24 + 12 N (1) 19 + 12 N (1) 44 + 23 N (1)

1 2 3 4 5 6

200

100

12

16

20

24

27

1 = 96 Kbit/s 2 = 192 Kbit/s

at 192 Kbit/s 17 + 06 N (1) 12 + 06 N (1) 29 + 115 N (1)

Event Device 1 CT1 CT1 Uni-Telway bus Device 2 BCT CT2 CT2 Action BCT = Uni-Telway bus cycle time CT1 = Device 1 bus cycle time CT2 = Device 2 bus cycle time

Report CT1 CT1 BCT

Slave to Master Slave to slave

In a distributed control system architecture the application-to-application response time depends not only on the communication system, but also on: b The processing times of the message source and destination devices b The degree of asynchronism between the bus and processor cycle times This response time must be evaluated by the designer of each application according to the devices which are connected The processing time of a device may vary from one to two cycle times depending on the degrees of asynchronism

Description

TSX Micro/Premium PLCs TSX Micro/Premium PLCs provide various ways of connecting to the Uni-Telway bus 1 By integrated TSX Micro/Premium processor or Atrium slot-PLC port The AUX port (2) (8-way mini-DIN) has one non-isolated RS 485 serial link channel (maximum distance 10 m) 2 By TSX SCY 21601 integrated port for Premium PLC or Atrium slot-PLC This module has one Half-duplex isolated RS 485 serial link channel, which is multiprotocol, including Uni-Telway 3 Via multiprotocol PCMCIA card A slot on the TSX 37 21/22/Premium PLC processors, the Atrium slot-PLC and the TSX SCY 21601 module (3) accepts the following multiprotocol cards: - TSX SCP 114 PCMCIA card: isolated RS 485/RS 422 link This type of card corresponds to the Uni-Telway standard - TSX SCP 111 PCMCIA card: non isolated RS 232 link This type of card can be used for direct point-to-point links or via Modem - TSX SCP 112 PCMCIA card: 20 mA current loop link This type of card is used for a multidrop link (2 to 16 devices) and requires a c 24 V external power supply

7 8 9

TSX Micro

3 Premium TSX SCY 21601 ___________________________________________________________________________ (1) N = Number of usable characters corresponding to the messages to be exchanged. (2) TER port for TSX 37 05/08/10 PLC. (3) This slot can also accept the TSX FPP 20 PCMCIA card for Fipway networks.

10

Connections: page 5/106

References: page 5/107

5/105

Connections

Modicon Premium automation platform


Uni-Telway serial link

Uni-Telway bus wiring system

1
12

2 3

4
Device

TSX 17 20

5
TER AUX

11

10 3

Adaptor
TSX Micro (TER terminal port)

Magelis XBT Gp

9
Altivar 71

7 13

Premium + TSX SCP 114

TSX Model 40

4 5 6 7 8 9 10

Premium + TSX SCY 21601

1 TSX CSA ppp: bus cable, double shielded twisted pair The shielding must be connected to the earth of each device 2 TSX SCA 50: passive T-junction box, matches the impedance when it is installed at the end of the line 3 TSX SCA 62: passive 2-channel Uni-Telway subscriber socket, is used for coding the address of two connected devices, and matching the impedance when it is installed at the end of the line 4 TSX SCA 60/61: passive terminal block, used for intermediate devices that have a 15-way female SUB D connector: - TSX SCA 60 used for intermediate devices, - TSX SCA 61 used for end devices 5 TSX P ACC 01: connection box, used for connecting a TSX Micro/Premium PLC to the Uni-Telway bus via the PLC terminal port The connecting cable (length 1 m) is integrated in the connection box It isolates the signals (for distances > 10 m) and is used to match the end of line impedance It is also used to set the operation of the terminal port (Uni-Telway Master/Slave or character mode) 6 TSX LES 64/74: cable connectors for extensions to the Uni-Telway bus, used to connect TSX model 40 PLC processors that have an integral Uni-Telway port as standard They are used for coding the address of the connected device 7 TSX SCP 114 : PCMCIA card for connecting TSX Micro (1)/Premium PLCs to the Uni-Telway bus 8 TSX SCP CU4030: Uni-Telway connecting cable between the TSX SCP 114 PCMCIA card (on TSX P57 p0M processor or TSX SCY 21601 module) and the TSX SCA 50 junction box 9 TSX SCY CU6530: Uni-Telway connecting cable between the TSX SCY 21601 module integrated channel and the TSX SCA 62 subscriber socket 10 VW3 A8 306: universal connecting cordset (length 3 m) between the Magelis XBT Gp Advanced Panel (port COM2, RJ45 connector) and the TSX SCA 62 subscriber socket 11 TSX PCX 1031: universal connecting cable between a PC compatible (COM port, 9-way SUB D connector) and the TER or AUX port for TSX Micro/Premium PLCs or the TSX P ACC 01 connection box (8-way mini-DIN connector) TSX CUSB 485 + TSX CRJDB 25: USB to RS 485 converter and Uni-Telway cordset between a PC compatible (USB port) and the TSX SCA 62 subscriber socket 12 TSX CSC 015: connecting cordset between the TSX 17 micro-PLC (via a TSX 17 ACC5 adapter or a TSX SCG 1161 module) and tha TSX SCA 62 subscriber socket 13 VW3 A8 306 2: connecting cordset (length 3 m) between the Altivar 61/71 speed drive and the TSX SCA 62 subscriber socket
(1) With TSX 37 21/22 PLCs. References: page 5/107

__________________________________________________________________

Characteristics: pages 5/104

Description: page 5/105

5/106

References

Modicon Premium automation platform


Uni-Telway serial link

Elements for connection to Uni-Telway bus


Description Protocol Physical layer Integrated link on processor Uni-Telway Non isolated RS 485 Character mode

PLC TSX Micro Premium Atrium

Rep.

Reference

Weight kg Please consult our site wwwschneider-electriccom See pages 1/12 and 1/31 See page 1/21 TSX SCY 21601 0360

1 2 3 4 5 6 7 8 9 10

Communication module TSX Micro

Uni-Telway 1 isolated 2-wire RS 485 Modbus/Jbus integrated channel Character mode (channel 0), 1 PCMCIA card slot (channel 1) (1)

Premium Atrium

PCMCIA cards for Premium processors, Atrium slot-PLCs, TSX 37 21/22 PLCs, TSX SCY 21601 modules Set of X-Way drivers for PC compatibles Premium TSX SCY 21601

Uni-Telway RS 232 (9 signals) 03192 Kbit/s Modbus/Jbus RS 485 (RS 422 compatible) Character mode 12192 Kbit/s 20 mA CL 12192 Kbit/s Includes all the X-Way drivers 1 CD-Rom

7 7 7

TSX SCP 111 TSX SCP 114 TSX SCP 112 TSX CD DRV 20M

0105 0105 0105

Uni-Telway bus connection accessories


Description Use Terminal port connection box Passive T-junction box

Rep.

Reference TSX P ACC 01

Isolation of Uni-Telway signals for bus length > 10 m, end 5 of line adaptation, bus cable tap links Supplied with cable (1 m length) equipped with a mini-DIN connector (TER or AUX ports) Tap link and extension of bus cable, 2 2-channel tap link (15-way female SUB-D connector) and 3 extension of bus cable, address coding and end of line adaptation Connection of an RS 232 device active adapter unit (using Uni-Telway protocol), adaptation and isolation of signals, end of line adaptation (no address coding)

Weight kg 0690

TSX SCA 50 TSX SCA 62 TSX SCA 72

0520 0570 0520

TSX SCP 11 p

Passive 2-channel subscriber socket Active adaptation box RS 232/RS 485

TSX P ACC 01

Uni-Telway bus connecting cables (2)


Description Double shielded twisted pair RS 485 cables Use From Uni-Telway bus To

Rep. 1

Length 100 m 200 m 500 m 3m 3m 3m 3m 04 m 25 m

Reference TSX CSA 100 TSX CSA 200 TSX CSA 500 TSX SCP CU 4030 TSX SCP CU 4530 TSX SCP CU 6030 TSX SCP CU 6530 TSX CUSB 485 (3) TSX CRJDB 25 (3) TSX PCX 1031 TSX CUSB 485 (4) TSX CRJDB 25 (4)

Weight kg 5680 10920 30000 0160 0180 0180 0200 0144 0160 0170 0144 0160

TSX SCA 50

TSX SCA 62

Cables for isolated RS 485 TSX SCP 114 tap link card

TSX SCA 50 T-jun box TSX SCA 62 sub sock

8 9

TSX SCY 21601 TSX SCA 50 T-jun box module integrat TSX SCA 62 sub sock channel (ch 0) TSX SCA 72 PC terminal (USB port) TSX SCA 62 sub sock

RS 232 terminal port/peripheral device connecting cable

TSX CUSB 485

TSX Micro/ Premium or Atrium port, TSX P ACC 01 box (TER or AUX)

RS 232 port for 9-way SUB D type PC compatible USB port of PC (USB/RS 485 converter) USB port of PC (mini-DIN/RJ45 cordset)

11

25 m 04 m 25 m

(1) Type III PCMCIA type III slot for TSX SCP 111/112/114, TSX FPP 20 card (2) For information on other connection cables, please see pages 5/108 (3) With TSX CUSB 485 converter, use the TSX CRJDB 25 cordset (equipped with 1 x 25-way SUB-D and 1 x RJ45). (4) With TSX CUSB 485 converter, use the TSX CRJDMD 25 cordset (equipped with 1 x mini-DIN and 1 x RJ45). TSX PCX 1031

Characteristics: pages 5/104 and 5/105

Description: page 5/105

Connections: page 5/106

5/107

Presentation, description, characteristics

Modicon Premium automation platform


Asynchronous serial links

Presentation

1 2

Premium

TSX SCY 21601

TSX Micro/Premium PLCs provide, via their processor, coprocessor or TSX SCY 21601 communication module, several possible ways for exchanging data in character mode with devices equipped with an asynchronous serial link interface: b RS 485 integrated port b Type III PCMCIA card with RS 232, RS 485 (RS 422 compatible) or 20 mA current loop link Protocols supported are character mode (ASCII), Uni-Telway and Modbus Other protocols are also available, or can be developed on request, on a RS 485 or RS 232 link, which enables TSX Micro/Premium PLCs to communicate on thirdparty architecturesThe list of modules available can be obtained from your Regional Sales Office, or from our Internet site wwwcollaborativeautomationcom

TSX Micro

Description
5 1

3 4 5 6 7
Services

Integrated links 1 Via integrated port on the processor or slot-PLC The AUX (1) port (8-way mini-DIN connector) has one non-isolated RS 485 serial link channel (maximum distance 10 m) 2 Via integrated port on the TSX SCY 21601 module This module for Premium PLCs has one isolated RS 485 serial link channel (25-way SUB-D connector) Half duplex multiprotocol, including Uni-Telway TSX SCP 11p multiprotocol PCMCIA cards 3 A slot on the processor, coprocessor and on the TSX SCY 21601 module takes cards which comprise: 4 A removable cover with fixing screws for access to the 20-way miniature connector 5 Two indicator lamps: - ERR lamp: card or link fault, - COM lamp: data transmission or reception To be ordered separately: TSX SCP Cp ppp cable
___________________________________________________________________________ (1) TER port for TSX Micro TSX 37 05/08/10 PLC. Non isolated Isolated RS 485 RS 485 terminal TSX SCY 21601 port integrated port (1) 12192 Kbit/s (2) 12192 Kbit/s 120 characters 7 or 8 bits 1 or 2 bits Even, odd or none PCMCIA card RS 232 PCMCIA card RS 485 RS 422 Compatible 03192 Kbit/s 12192 Kbit/s 4096 characters max PCMCIA card 20 mA current loop (3)

Characteristics
Type

Physical layer Transmission

8 9 10
References: page 5/109

Data rate Size Data Stop bit Parity bit Stop on silence Reception echo Repeat 1st char echo Auto LF Back space Beep Flow mgmt by Xon-Xoff byRTS/CTS RTS/CTS delay Stop on reception End of message PSR management

Parameters which can be accessed in configuration mode. ___________________________________________________________________________ (1) Half-duplex line in RS 485, Full-duplex in RS 422. (2) With the TSX P57 3p3M/4p3/3p4M processor, data rate up to 115 Kbit/s during program uploading. (3) Point-to-point or multidrop link.

5/108

References

Modicon Premium automation platform


Asynchronous serial links

References
Description

Asynchronous serial link elements (character mode)


Protocol Character mode Uni-Telway Physical layer RS 485 non-isolated PLC TSX Micro Premium Atrium TSX Micro Communication module Character mode Uni-Telway Modbus/Jbus Character mode Uni-Telway Modbus/Jbus - 1 isolated RS 485 integrated Premium Atrium channel (channel 0), - 1 PCMCIA card slot (channel 1) (1) RS 232 (9 signaux) 0,319,2 Kbit/s RS 485 (compatible RS 422) 1,219,2 Kbit/s BC 20 mA 1,219,2 Kbit/s Reference Weight kg Integrated link on processor Consult our site wwwschneider-electriccom See pages 1/12 and 1/31 See page 1/21 TSX SCY 21601 0360

1 2 3 4

PCMCIA cards for TSX 37 21/22 PLC, Premium processor, Atrium slot-PLCs, TSX SCY 21601 module

TSX SCP 111 TSX SCP 114 TSX SCP 112

0105 0105 0105

Asynchronous serial link connection accessories


Description TSX SCY 21601 Terminal port connection box Use Isolation of RS 485 signals, end of line adaptation Supplied with cable for connection to PLC Length 1m Reference TSX P ACC 01 Weight kg 0690

Premium

Connecting cables for asynchronous serial links


Use From To RS 485/RS 422 device Cables for isolated RS 485 TSX SCP 114 card connection (2) Integrated channel RS 485/RS 422 device (3) via (channel 0) TSX SCA 50 box TSX SCY 21601 module Universal cable for TSX Micro/Premium/ RS 232 of a terminal device terminal port/RS 232 Atrium integrated port (DTE) (4) device (TER or AUX) USB port of PC TSX P ACC 01 box (USB/RS 485 converter) USB port (mini-DIN/RJ45 cordset Cables for RS 232 TSX SCP 111 card Communication device: connection modem, converter, (DCE) (3) Point-to-point terminal device (DTE) (3) Cable for BC 20 mA connection TSX SCP 112 card Current loop device (2) Description Length 3m 3m Reference TSX SCP CX 4030 TSX SCY CU 6030 Weight kg 0160 0180

TSX SCP 11p

5 6 7 8 9 10

25 m 04 m 25 m 3m 3m 10 m 3m

TSX PCX 1031 TSX CUSB 485 (5) TSX CRJMD 25 (5) TSX SCP CC 1030 TSX SCP CD 1030 TSX SCP CD 1100 TSX SCP CX 2030

0170 0144 0150 0190 0190 0620 0160

TSX P ACC 01

TSX CUSB 485

(1) PCMCIA type III slot can receive one TSX SCP 111/112/114 or TSX FPP 20 card. (2) End of cable with flying leads. (3) End of cable fitted with a 25-way male SUB-D connector. (4) End of cable fitted with a 9-way male SUB-D connector. For use, to order separatly one TSX CTC 10 adaptator (9-way male SUB-D connector/25-way male SUB-D connectors). (5) With TSX CUSB 485 converter, use the TSX CRJMD 25 cordset (equipped with 1 x mini-DIN and 1 x RJ45).

Presentation: page 5/108

Description: page 5/108

Characteristics: page 5/108

5/109

References

Modicon Premium automation platform

Connecting cables for PCMCIA cards and TER/AUX ports


TSX Micro/Premium PLC TSX SCP 111 PCMCIA card Device to be Physical link connected DTE terminal 2 RS 232D Protocol Character mode Length 3m 10 m Reference Weight kg TSX SCP CD 1030 0190 TSX SCP CD 1100 0620

1 2

DCE terminal RS 232D (Modem) 2

Character mode Uni-Telway

3m

TSX SCP CC 1030

0190

TSX SCP 114 PCMCIA card

3 4 5 6 7 8 9 10
1 2 3 4 5 6
TSX SCP 112 PCMCIA card

TSX SCA 50 RS 485 Character mode T-junction box (2-wire isolated) Uni-Telway 3 RS 422/485 Character mode (2-wire isolated) Modbus TSX SCA 62 RS 485 Uni-Telway 2-channel (2-wire isolated) subscriber socket 4

3m 3m

TSX SCP CU 4030 TSX SCP CM 4030

0160 0160

3m

TSX SCP CU 4530

0160

TSX SCA 64 RS 422/485 2-channel (2/4 wire) subscriber socket 4

Modbus

3m

TSX SCP CM 4530

0180

DTE Terminal 3 RS 422/485 (4-wire)

Modbus

3m

TSX SCP CX 4030

0160

Active or passive terminal

20 mA current loop

Character mode Uni-Telway Modbus

3m

TSX SCP CX 2030

0160

TER/AUX ports 1

TSX P ACC 01 RS 485 junction box

Uni-Telway

1m

Included with TSX P ACC 01

TSX P ACC 01 RS 485 junction box 5

Uni-Telway

2m 5m

T FTX CB1 020 T FTX CB1 050

0100 0190

DTE terminal (PC, printer)

RS 232 6 RS 232

Character mode Character mode

2,5 m 0,4 m 2,5 m

TSX PCX 1031 (1) TSX CUSB 485 (2) TSX CRJMD 25 (2)

0170 0,144 0150

25-way male miniature connector 25-way male SUB-D connector Flying leads 15-way male SUB-D connector 8-way female mini-DIN connector 9-way female SUB-D connector

(1) Separate parts see page 5/111. (2) The TSX CUSB 485 requires to use with the TSX CRJMD 25 cordset (equiped to mini-DIN connector and RJ45 connector).

5/110

References (continued)

Modicon Premium automation platform

Connecting cables for PCMCIA cards and TER/AUX ports


TSX Micro/Premium PLC TER/AUX ports (contin) 1 Device to be Physical link connected DTE terminal RS 232 (slave PC ) 2 RS 485 USB Protocol Uni-Telway Uni-Telway Length 25 m 0,4 m 2,5 m Reference TSX PCX 1031 TSX CUSB 485 (1) TSX CRJMD 25 (1) Weight kg 0170 0,144 0150

1 2 3 4 5 6 7 8 9 10

DTE terminal RS 232 (printer, slave PC without RTS) 2 RS 232

Character mode Uni-Telway Character mode Uni-Telway Character mode Uni-Telway

25 m 0,4 m 2,5 m 3m

TSX PCX 1031 (2) TSX CUSB 485 (1) TSX CRJMD 25 (1) TSX PCX 1130 (3)

0170 0,144 0150 0140

DCE terminal RS 232 (Modem M/Sl USA/Europe) 4

Magelis XBT GTp terminal

RS 485 3

Uni-Telway

2,5 m 5m

XBT Z968 + XBT ZG909 XBT Z9681 + XBT ZG909

(4) (4)

0,180 0,340

TSX SCY 21601 communication module integrated port 5

TSX SCA 50 RS 485 Uni-Telway T-junction box 5 (2-wire isolated) Modbus

3m 3m

TSX SCY CU 6030 TSX SCY CM 6030

0180 0180

TSX SCA 62 RS 485 Uni-Telway 2-channel (2-wire isolated) subscriber socket 6

3m

TSX SCY CU 6530

0200

RS 485 terminal

RS 485 Character mode 5 (2-wire isolated)

3m

TSX SCY CM 6030

0180

Separate parts
Description SUB-D adapter Description Reference 9-way male SUB-D connector/25-way female SUB-D connectors TSX CTC 07 9-way male SUB-D connector/25-way male SUB-D connector TSX CTC 10 Weight kg 0060 0060

1 2 3 4 5 6

8-way female mini-DIN connector 9-way female SUB-D connector 9-way male SUB-D connector 25-way male SUB-D connector Flying leads 15-way male SUB-D connector

(1) The TSX CUSB 485 requires to use with the TSX CRJMD 25 cordset (equiped to mini-DIN connector and RJ45 connector). (2)To be ordered separatly: TSX CTC 07 and TSX CTC 10 adapters, see above separate parts. (3) Point to point, supplied wih 1 SUB-D adapter: TSX CTC 09 9-way female/25-way male SUB-D connector. (4) For connection to Magelis XBT GK/GW, consult our catalogue Human/Machine Interfaces.