You are on page 1of 12

AMVC95/ACVC95

AMVC95: up to 96% AFue ACVC95: up to 95% AFue


HeAtinG input:
Standard Features

GAs FurnACes

46,000115,000 Btu/H

MillionAir stainless-steel, dual-diameter tubular heat exchanger Two-stage gas valve operates on two-stage or single-stage thermostats ComfortNet Communications System compatible Efficient and quiet variable-speed ECM circulator motor gently ramps up or down according to heating or cooling demand SureStart Silicon Nitride igniter designed for long igniter life Furnace control board with self-diagnostics, color-coded low-voltage terminals, and provisions for electronic air cleaner and 115-volt or 24-volt humidifiers Low constant fan allows homeowner to activate very low speed to efficiently circulate air throughout the home. This setting costs as little as a 100-watt light bulb to operate. Dual-certified for sealed combustion direct vent (2-pipe) or non-direct vent (1-pipe) applications Easy-to-install top venting is standard; alternate flue/vent locations available Quiet, two-speed induced draft blower All models comply with California NOx emissions standards

Cabinet Features

Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish Designed for multi-position installation AMVC95: upflow, horizontal left or right ACVC95: downflow, horizontal left or right Airtight solid bottom for side return applications & easy-cut tabs for effortless removal in bottom air inlet applications Convenient left or right connection for gas/electric service Coil and furnace fit flush for most installations

Contents

Nomenclature....................................................................................................2 Product Specifications..................................................................................3 Dimensions .........................................................................................................4 AMVC95 Airflow Specifications ...............................................................6 ACVC95 Airflow Specifications ................................................................9 Wiring Diagram ..............................................................................................10 Thermostats.......................................................................................................11 Accessories.........................................................................................................11

* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Unit Replacement Limited Warranty (good for as long as you own your home) and the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Qubec.

SS-AMVC95

Amana is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.

www.amana-hac.com

Supersedes 8/10

9/10

produCt speCiFiCAtions

noMenClAture
A 1 M 2 V 3 C 4 95 5,6 070 7,8,9 4 10 C 11 X 12 A 13 A 14

Brand A Amana Brand

A B C

Revisions Ini,al Releases (Major & Minor) 1st Revisions (Major & Minor) 2nd Revisions NOx N X Natural Gas Low NOx Cabinet Width A 14 B 17 C 21 D 24 Maximum CFM @ 0.5 ESP 3 1200 4 1600 5 2000 MBTU/h 045: 45,000 070: 70,000 090: 90,000 115: 115,000 140: 140,000

Airow Direc5on C Downow/Horizontal D Dedicated Downow H High Airow K Dedicated Upow M Upow/Horizontal Descrip5on/Motor V Two-Stage/Variable-speed H Two-Stage/Mul,-speed S Single-Stage/Mul,-speed E Two-Stage/High-Eciency SystemType C ComfortNet Communica,ng System AFUE 95 95% 9 90%+ 8 80%

Important EnergyStar Notice: EnergyStar ratings are dependent upon conditions beyond equipment installation. Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet EnergyStar criteria. Ask your contractor for details or visit www.energystar.gov.

www.amana-hac.com

SS-AMVC95

produCt speCiFiCAtions

speCiFiCAtions
AMVC95 0453BX Heating Capacity High Fire Input (BTU/h) High Fire Output (BTU/h) Low Fire Input (BTU/h) Low Fire Output (BTU/h) AFUE Available AC @ 0.5 ESP Temperature Rise Range ( F) Circulator Blower Size (D x W) Horsepower @ 1050 RPM Speed Vent Diameter No. of Burners Disposable Filter (in2) Electrical Data Min. Circuit Ampacity4 MOP (amps)5 Ship Weight (lbs)
1 2 3

AMVC95 0704CX

AMVC95 0905CX

AMVC95 0905DX

AMVC95 1155DX

ACVC95 0714CX

ACVC95 0915DX

46,000 45,000 32,000 30,800 96 1.5 - 3.0 30 - 60

69,000 67,000 48,000 46,400 95.5 1.5 - 4.0 30 - 60

92,000 90,000 64,000 61,700 95.7 2.0 - 5.0 30 - 60

92,000 90,000 64,000 61,700 95.7 2.0 - 5.0 30 - 60

115,000 109,000 80,000 77,400 95.8 2.0 - 5.0 35 - 65

69,000 65,000 48,000 45,000 95 1.5 - 4.0 30 - 60

92,000 87,000 64,000 60,000 95 2.0 - 5.0 30 - 60

10 X 8

10 X 10

11 X 10 1 Variable

11 X 10 1

11 X 10 1

10 X 10

11 X 10 1

Variable 3 4 960 3 5 972 2 3 641* 2 4 854*

2 2 576

2 3 768

3 4 960

11.3 15 121

14.1 15 145

14.4 15 160

14.4 15 160

14.4 15 170

14.1 15 139

14.4 15 165

Natural Gas BTU/h DOE AFUE based upon Isolated Combustion System (ICS) Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes: 1. All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. 2. Gas Service Connection FPT 3. Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

SS-AMVC95

www.amana-hac.com

Product SPecificationS

aMVc95 diMenSionS

28 19 2 2/

2/

1 30 24/ 1 2 21 19/ 1 11 16 32/ 27 30

6 2

19/ 11 1

22 / FOLDED FLANGES 23 / UNFOLDED FLANGES

FOLDED FLANGES

D
UNFOLDED FLANGES

LEFT SIDE VIEW

E FRONT VIEW

RIGHT SIDE VIEW

Model AMVC950453BX AMVC950704CX AMVC950905CX AMVC950905DX AMVC951155DX

A 17 21 21 24 24

B 16 19 19 19 23

C 13 16 16 16 20

D 12 16 16 16 19

E 13 17 17 17 20

Notes: Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of furnace. Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details. Installer must supply following gas line fittings, according to which entrance is used: LeftTwo 90 elbows, one close nipple, straight pipe RightStraight pipe to reach gas valve For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.

MiniMuM clearanceS to coMbuStible MaterialS


Position Upflow Horizontal Sides 0 6 Rear 0 0 Front 3 3 Bottom C C Flue 0 0 Top 1 6

C = If placed on combustible floor, the floor MUST be wood ONLY. Notes: For servicing or cleaning, a 24 front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

www.amana-hac.com

SS-AMVC95

produCt speCiFiCAtions

ACVC95 diMensions
LEFT SIDE VIEW 28 3/4 3/4 20 1/4 2 1/2 AIR INTAKE PIPE 2" PVC 3/4 FRONTVIEW RIGHT SIDE VIEW

A
(RETURN)

3/4 2 1/16 CONDENSATE DRAIN TRAP w/ 3/4" PVC DISCHARGE (RIGHT OR LEFT SIDE)

VENT/FLUE PIPE 2" PVC

1 3/4

LOW VOLTAGE ELECTRICAL HOLE

1 3/4 40

LOW VOLTAGE ELECTRICAL HOLE HIGH VOLTAGE ELECTRICAL HOLE ALTERNATE VENT/FLUE LOCATION ALTERNATE AIR INTAKE LOCATION 2 5/8 TRAP C L RIGHT SIDE DRAIN LINE HOLES 7 3/8 ALTERNATE GAS SUPPLY HOLE
DRAIN

28 5/16 HIGH VOLTAGE ELECTRICAL HOLE DRAIN TRAP 2 5/8 C L

28 5/16

6 1/8 2 11/16

19 7/8 18 13/16 15 1/2 11 1/2 9 13/16 2 8 1/4 14 11 5/8 9 3/4

LEFT SIDE DRAIN LINE HOLES STANDARD GAS SUPPLY HOLE

4 1/8

18 5/8 FOLDED FLANGES UNFOLDED FLANGES 20 5/32 UNFOLDED FLANGES FOLDED FLANGES AIR DISCHARGE

UNFOLDED FLANGES FOLDED FLANGES FOLDED FLANGES UNFOLDED FLANGES DISCHARGE

D E

AIR DISCHARGE

Model ACVC950714CX ACVC950915DX

A 21 24

B 19 23

C 16 20

D 18 21

E 19 23

Notes: Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of furnace. Conversion kits for high-altitude natural gas operation are available. Contact your Amana distributor or dealer for details. Installer must supply following gas line fittings, according to which entrance is used: LeftTwo 90 Elbows, one close nipple, straight pipe RightStraight pipe to reach gas valve

MiniMuM CleArAnCes to CoMBustiBle MAteriAls


Position Downflow Horizontal Sides 0 6 Rear 0 0 Front 3 3 Bottom NC C Flue 0 0 Top 1 6

C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. Notes: For servicing or cleaning, a 24 front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

SS-AMVC95

www.amana-hac.com

produCt speCiFiCAtions

AMVC95 AirFlow speCiFiCAtions


CoolinG speeds
AMVC950453BX AMVC950704CX

Tap
A

High Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
540 600 660 720 800 880 900 1000 1100 1080 1200 1320

Tap
A

Low Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
351 390 429 468 520 572 585 650 715 702 780 858

Tap
A

High Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
540 600 660 720 800 880 990 1100 1210 1286 1429 1572

Tap
A

Low Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
351 390 429 468 520 572 644 715 787 836 929 1022

AMVC950905CX

AMVC950905DX

Tap
A

High Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
729 810 891 990 1100 1210 1323 1470 1617 1629 1810 1991

Tap
A

Low Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
495 550 605 693 770 847 900 1000 1100 1125 1250 1375

Tap
A

High Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
720 800 880 900 1000 1100 1260 1400 1540 1620 1800 1980

Tap
A

Low Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
468 520 572 644 715 787 819 910 1001 1053 1170 1287

AMVC951155DX

Tap
A

High Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
720 800 880 990 1100 1210 1260 1400 1540 1620 1800 1980

Tap
A

Low Stage Adjust


Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+) Minus(-) Normal Plus (+)

CFM*
468 520 572 644 715 787 819 910 1001 1053 1170 1287

* @ .1" - .8" w.c. ESP Notes: All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. Do not operate above .5 w.c. ESP in heating mode. Operating CFM between .5 and .8 w.c. is tabulated for cooling purposes only.

www.amana-hac.com

SS-AMVC95

Product SPecificationS

aMVc95 airflow SPecificationS (cont.)


Heating SPeedS
Tap A AMVC950453BX (Rise Range: 30 - 60F) Low-Stage High-Stage Adjust CFM * CFM * Minus(-) 495 713 Normal 550 792 Plus (+) 605 871 Minus(-) 540 778 Normal 600 864 Plus (+) 660 950 Minus(-) 585 842 Normal 650 936 Plus (+) 715 1,030 Minus(-) 630 907 Normal 700 1,008 Plus (+) 770 1,109 AMVC950905CX (Rise Range: 30 - 60F) Low-Stage High-Stage Adjust CFM * CFM * Minus(-) 945 1,341 Normal 1,050 1,490 Plus (+) 1,155 1,639 Minus(-) 1,008 1,413 Normal 1,120 1,570 Plus (+) 1,232 1,727 Minus(-) 1,080 1,521 Normal 1,200 1,690 Plus (+) 1,320 1,859 Minus(-) 1,125 1,602 Normal 1,250 1,780 Plus (+) 1,375 1,958 AMVC951155DX (Rise Range: 35 - 65F) Low-Stage High-Stage Adjust CFM * CFM * Minus(-) 1,107 1,594 Normal 1,230 1,771 Plus (+) 1,353 1,948 Minus(-) 1,139 1,639 Normal 1,265 1,822 Plus (+) 1,392 2,004 Minus(-) 1,170 1,685 Normal 1,300 1,872 Plus (+) 1,430 2,059 Minus(-) 1,202 1,730 Normal 1,335 1,922 Plus (+) 1,469 2,115 Rise (F) 57 41 46 52 47 43 48 43 39 45 40 36 Tap A AMVC950704CX Rise Range: 30 - 60F) Low-Stage High-Stage Adjust CFM * CFM * Minus(-) 756 1,089 Normal 840 1,210 Plus (+) 924 1,331 Minus(-) 828 1,192 Normal 920 1,325 Plus (+) 1,012 1,457 Minus(-) 900 1,296 Normal 1,000 1,440 Plus (+) 1,100 1,584 Minus(-) 972 1,400 Normal 1,080 1,555 Plus (+) 1,188 1,711 AMVC950905DX (Rise Range: 30 - 60F) Low-Stage High-Stage Adjust CFM * CFM * Minus(-) 1,013 1,458 Normal 1,125 1,620 Plus (+) 1,238 1,782 Minus(-) 1,076 1,549 Normal 1,195 1,721 Plus (+) 1,315 1,893 Minus(-) 1,139 1,640 Normal 1,265 1,822 Plus (+) 1,392 2,004 Minus(-) 1,202 1,730 Normal 1,335 1,922 Plus (+) 1,469 2,114 Rise (F) 56 50 46 51 46 42 47 42 38 43 39 35

Tap A

Rise (F) 60 54 49 57 51 47 53 48 43 50 45 41

Tap A

Rise (F) 55 50 45 52 47 43 49 44 40 47 42 38

Tap A

Rise (F) 63 57 52 62 56 50 60 54 49 58 53 48

* @ .1" - .5" w.c. ESP Notes All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. Do not operate above .5 w.c. ESP in heating mode. Operating CFM between .5 and .8 w.c. is tabulated for cooling purposes only.
SS-AMVC95 www.amana-hac.com 7

produCt speCiFiCAtions

ACVC95 AirFlow dAtA


ACVC950714CX Cooling Speeds High Stage Tap A Adjust Minus Normal Plus Minus B Normal Plus Minus C Normal Plus Minus D Normal Plus * @ .1" - .5" w.c. ESP ACVC950915DX Cooling Speeds High Stage Tap A Adjust Minus Normal Plus Minus B Normal Plus Minus C Normal Plus Minus D Normal Plus CFM* 729 810 891 999 1110 1221 1287 1430 1573 1674 1860 2046 D C B A Tap Low Stage Adjust Minus Normal Plus Minus Normal Plus Minus Normal Plus Minus Normal Plus CFM* 504 560 616 666 740 814 828 920 1012 1071 1190 1309 D C B A Tap Adjust Minus Normal Plus Minus Normal Plus Minus Normal Plus Minus Normal Plus ACVC950915DX Heating Speeds (Rise Range: 25 - 55F) High Stage CFM* 1458 1620 1782 1575 1750 1925 1674 1860 2046 1773 1970 2167 Rise 55 50 45 51 46 42 48 43 39 45 41 37 D C B A Tap Low Stage Adjust Minus Normal Plus Minus Normal Plus Minus Normal Plus Minus Normal Plus CFM* 1008 1120 1232 1098 1220 1342 1152 1280 1408 1206 1340 1474 Rise 80 72 65 73 66 60 70 63 57 67 60 55 CFM* 594 660 726 747 830 913 1017 1130 1243 1314 1460 1606 D C B A Tap Low Stage Adjust Minus Normal Plus Minus Normal Plus Minus Normal Plus Minus Normal Plus CFM* 324 360 396 468 520 572 702 780 858 864 960 1056 D C B A Tap Adjust Minus Normal Plus Minus Normal Plus Minus Normal Plus Minus Normal Plus ACVC950714CX Heating Speeds (Rise Range: 25 - 55F) High Stage CFM* 1107 1230 1353 1215 1350 1485 1323 1470 1617 1440 1600 1760 Rise 55 49 45 50 45 41 46 41 37 42 38 34 D C B A Tap Low Stage Adjust Minus Normal Plus Minus Normal Plus Minus Normal Plus Minus Normal Plus CFM* 783 870 957 855 950 1045 936 1040 1144 1017 1130 1243 Rise 77 69 63 71 64 58 65 58 53 59 53 49

* @ .1" - .5" w.c. ESP Notes All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. Do not operate above .5 w.c. ESP in heating mode. Operating CFM between .5 and .8 w.c. is tabulated for cooling purposes only.

Continous Fan Speeds


Model AMVC950453BX AMVC950704CX AMVC950905C/DX AMVC951155DX Maximum CFM 1400 1760 2200 2200 Continuous Fan Speed 420 530 660 660 Model ACVC950714CX ACVC950915DX Maximum CFM 1760 2200 Continuous Fan Speed 530 660

Continuous fan speed is 30% of furnace maximum CFM

www.amana-hac.com

SS-AMVC95

SS-AMVC95

wirinG diAGrAM witH Honywell VAlVe

www.amana-hac.com

Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.

Warning

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.

produCt speCiFiCAtions

Product SPecificationS

Wiring diagram With White-rodgerS ValVe


GND ID BLOW ER TW O-STAGE PRESSURE SW ITCH ASSEMBLY L TO 115 VAC/ 1 /60 HZ POW ER SUPPLY W ITH OVERCURRENT PROTECTION DEVICE

JUNCTION BOX

HOT LOW FIRE SURFACE PRESSUR IGNITER E SWITCH 2 CIRCUIT 2 1 CONNECTOR

OR
C NO

24V HUM.
C NO

HIGH FIRE PRESSURE SW ITCH

BK WH
DISCONNECT N

WARNING:DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED.

YL

PM

GY

NO

GY
FRONT COVER PRESSURE SWITCH

DISCONNECT

BL

M ANUAL RESET ROLLOUT LIMIT CONTROLS (SINGLE CONTROL ON 45 kBTU)

PK
AUTO RESET PRIMARY LIM IT CONTROL

OR

DOOR SWITCH JUNCTION BOX

PU
INDUCED DRAFT BLOW ER GND

3 2

WH RD BK

INDUCTOR COIL 70kBTU,90kBTU, 115kBTU MODELS ONLY

INDOOR AIR CIRCULATOR BLWR

GND
LINE NEUTRAL EAC

BURNER COMPARTM ENT BLOW ER COMPARTM ENT


MANUAL RESET AUXILIARY LIMIT CONTROL
24 V THERMOSTAT CONNECTIONS

PU

ELECTRONIC AIR CLEANER IND HI ID BLWR


IND LO

NEUTRAL

YL YL PK GY

NEUTRAL

FUSE
1

24 V 3A

HUM

HUMIDIFIER

NEUTRAL

IGN HOT SURFACE IGNITER

NEUTRAL

DIAGNOSTIC LED'S

SEE NOTE 5

BR
3 6 9 12 15 2 5 8 11 14 1 4 7 10 13

OR OR
OR PK GY BR
24V THERMOSTAT CONNECTIONS
R

FS

2ND STG DLY T-STAT HEAT OFF DELAY DIP SWITCHES UNUSED DEHUM HEAT DELAY ADJUST COOL

FLAME SENSOR LINE 115 VAC

NEUTRAL
40 VA TRANSFORMER

FUSE 3 A

TH (4)

1 2
3 4

YL

PU

TO +VDC

24 VAC MANUAL RESET AUXILIARY LIMIT CONTROLS HLO (10)

AUTO RESET PRIMARY LIMIT CONTROL

GY

OR
24 VAC 115 VAC

Y1

PSO (7)
W1 24V HUM.

PS1 (2)

LOW FIRE PRESS. SWITCH

NO

LINE

BK
FS EAC

2 3

40 VA TRANSFORMER

Y2 G O
DEHUM

TO MICRO

PS2 (12) NO
HIGH FIRE PRESS. SWTICH

C
MANUAL RESET ROLLOUT LIMIT CONTROLS

WH

MVL (13)
MVH (14) C

NO
FRONT COVER PRESS. SWITCH

PM

RD

HI
C
GAS VALVE

GY

WH BK BK

GND (5) TR (11)


TO R GND (4) + VDC (1) RX (2) TO MICRO TX (3) INDOOR AIR CIRCULATOR BLWR
GND

BK

5 4 3 2 1

BK GR PK

BK
WH
GND

CIRCULATOR BLOWER

INDUCTOR COIL 70kBTU,90kBTU, 115kBTU MODELS ONLY

BLOWER COMPARTMENT DOOR SWITCH (OPEN WHEN DOOR OPEN)

INTEGRATED CONTROL MODULE

HUMIDIFIER

NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS)

COLOR CODES: PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK

LOW VOLTAGE (24V)


LOW VOLTAGE FIELD

EQUIPMENT GND
FIELD GND FIELD SPLICE

HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION

SWITCH (TEMP.) IGNITER


SWITCH (PRESS.)

OVERCURRENT PROT. DEVICE

0140F00530

REV. B

10

www.amana-hac.com

Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.

ECM MTR HARNESS

BL

WH
4

MVC (8)

SS-AMVC95

WH

NEUTRAL

HLI (1)

Warning

BL
5 CIRCUIT CONNECTOR

W2

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.

TW O STAGE GAS VALVE

BR
C

FLAME SENSOR

WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED.

GND

INTEGRATED CONTROL MODULE

HI

PU

OR

TO 115VAC/ 1 /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE

RD WH

CHASSIS GROUND

BL

BR OR PU BR

GN
INTEGRATED CONTROL MODULE

WH RD BK WH RD

W1

W2

DEHUM

Y2

Y1

TWO-STAGE INTEGRATED CONTROL MODULE


4 CIRCUIT MOTOR CONNECTOR

HUM

24V HUM.

Product SPecificationS

acceSSorieS
Model LPM-05 LPM-06 ASAS AMU DEHUM1 HAPS28 HAPS29 HAPS 31 HALP11 HALP 13 HANG 13 HANG 14 HANG 16 EFR01 DCVK-20 DCVK-30 CFB21 CFB24 017K00000S Description LP Conversion Kit (springs & orifice) LP Conversion Kit (springs & orifice) Electronic Air Cleaners (-10, -11, -12 or -18) Media Air Cleaners (1620, 2020, 1625 or 2025) Dehumidistat High-Altitude Pressure Switch Kit High-Altitude Pressure Switch Kit High-Altitude Pressure Switch Kit High-Altitude Propane Gas Kit High-Altitude Propane Gas Kit High-Altitude Natural Gas Kit High-Altitude Natural Gas Kit High-Altitude Natural Gas Kit External Filter Rack Horizontal/Vertical Concentric Vent Kit (2) Horizontal/Vertical Concentric Vent Kit (3) Downflow Floor Base Downflow Floor Base Flush-mount vent kit White-Rodgers and Honeywell valves 3 4 3 4 3 4 3 4 2 2 2 2 2 2 2 2 AMVC95 0453BX 1 1 2 AMVC95 0704CX 1 1 2 2 2 2 2 AMVC95 0905C/DX 1 1 AMVC95 1155DX 1 1 ACVC95 0714CX 1 1 ACVC95 0915DX 1 1

White-Rodgers valve only

Notes Indicates available for this model 2 Indicates 9,001 to 11,000 altitude 1 Indicates 7,001 to 9,000 altitude 3 Indicates 7,001 to 11,000 altitude All installations above 7,000 require a pressure switch change. For installation in Canada, gas furnaces are certified only to 4,500.

thermoStatS
ATS1175 ATS3275 ATS 4275 Touch-Screen Digital Thermostats (See Amana Thermostat specification sheets for details.)

A2111 A3272 A3273

Touch-Screen Digital Thermostats (See Amana Thermostat specification sheets for details.)

A1100 A2100 A1152 A2152

Programmable and Non-programmable Digital Thermostats (See Amana Thermostat specification sheets for details.)

SS-AMVC95

www.amana-hac.com

11