Professional Documents
Culture Documents
URNP-SANA
2003-12-15
Revision Record
Date 2003/12/15 2005/03/16 1.0 Rev. Version Initial transmittal Change the date, no content updated. Description Author Znag Liang Qinyan
11-8-23
Confidential
Page 2 of 52
Table of Contents
1 Introduction..................................................................................................................................................7 2 Handover Algorithm Analysis.....................................................................................................................7 2.1 Handover Measurement ..........................................................................................................................7 2.1.1 Intra-Frequency Measurement .........................................................................................................8 2.1.2 Inter-Frequency Measurement .......................................................................................................13 2.1.3 Inter-System Measurement ............................................................................................................15 2.1.4 UE Internal Measurement ..............................................................................................................16 2.2 Handover Algorithms ...........................................................................................................................16 2.2.1 Softer Handover and Soft Handover Algorithms ...........................................................................16 2.2.2 Intra-Frequency Hard Handover Algorithm ..................................................................................18 2.2.3 Inter-Frequency Hard Handover Algorithm ..................................................................................18 2.2.4 Inter-System Handover Algorithm .................................................................................................19 2.2.5 Handover Caused by Load Balancing ............................................................................................20 2.2.6 Cell Penalty.....................................................................................................................................21 2.2.7 Active Set Synchronization Maintenance.......................................................................................21 2.2.8 Direct Retry Algorithm ..................................................................................................................23 2.2.9 Principle for Generating Adjacent Cell List...................................................................................24 3 Handover Parameter Setting ......................................................................................................................25 3.1 Description.............................................................................................................................................25 3.2 Handover Common Parameters ............................................................................................................26 3.2.1 Maximum Number of Cells in Active Set......................................................................................26 3.2.2 Penalty Time....................................................................................................................................27 3.2.3 Event 6F Trigger Threshold ...........................................................................................................27 3.2.4 Event 6G Trigger Threshold...........................................................................................................28 3.2.5 Time-to-Trigger Parameters for Events 6F and 6G........................................................................29 3.2.6 BE Service Handover Rate Decision Threshold ............................................................................29 3.2.7 Soft Handover Method Select Switch ............................................................................................30 3.2.8 Handover Algorithm Switches........................................................................................................31 3.3 Intra-Frequency Handover Measurement Algorithm Parameters ........................................................32 3.3.1 Soft Handover Relative Thresholds ...............................................................................................32 3.3.2 Soft Handover Absolute Thresholds ..............................................................................................33 3.3.3 Intra-Frequency Measurement Filter Coefficient (FilterCoef).......................................................34 3.3.4 Hysteresis Related to Soft Handover .............................................................................................35 3.3.5 Time-to-Trigger Parameters Related to Soft Handover..................................................................37 3.3.6 WEIGHT.........................................................................................................................................38 3.3.7 Detected Set Statistics Switch.........................................................................................................38 3.4 Inter-Frequency Handover Algorithm Parameters ...............................................................................39 3.4.1 Inter-Frequency Measurement Filter Coefficient (FilterCoef).......................................................39 3.4.2 Cell Location Property....................................................................................................................40 3.4.3 Hysteresis Related to Inter-Frequency Handover...........................................................................41 3.4.4 Time-to-Trigger Parameters Related to Inter-Frequency Hard Handover.....................................41 3.4.5 Compressed Mode Enable/Disable Threshold Denoted by RSCP.................................................42 3.4.6 Compressed Mode Enable/Disable Threshold Denoted by Ec/No.................................................43 3.4.7 Inter-Frequency Hard Handover RSCP Threshold ........................................................................44 3.4.8 Inter-Frequency Hard Handover Ec/No Threshold ........................................................................44 3.5 inter-system handover measurement algorithm parameter ..................................................................45 3.5.1 inter-system measurement filter coefficient FilterCoef..................................................................45 3.5.2 Inter-System Hard Handover Decision Threshold .........................................................................46 3.5.3 Inter-system Hard Handover Hysteresis .......................................................................................46 3.5.4 Time-to-Trigger Parameter for Inter-System Hard Handover........................................................47 3.5.5 Inter-System Measurement Periodic Report Interval.....................................................................47 3.6 Compressed Mode Algorithm Parameter .............................................................................................48 3.6.1 CFN Offset to Enable Compressed Mode.......................................................................................48
11-8-23
Confidential
Page 3 of 52
3.6.2 Spreading Factor Threshold ...........................................................................................................49 3.7 Direct Retry Algorithm Parameter .......................................................................................................49 3.7.1 Maximum Direct Retry Times........................................................................................................49 3.7.2 Candidate Set Absolute Threshold .................................................................................................50 3.7.3 Minimum Ec/No Value...................................................................................................................50 3.7.4 Linear Factor of Relative Threshold and Time Interval.................................................................51 3.7.5 Maximum Relating Time for Direct Retry Decision......................................................................52
11-8-23
Confidential
Page 4 of 52
List of Tables
table 1Recommended Soft Handover Hysteresis Settings for Different Movement Speeds.......................36 table 2Recommended Time-to-Trigger Settings for Different Movement Speeds......................................37 table 3Recommended Inter-Frequency Hard Handover Hysteresis Settings for Different Movement Speeds..........................................................................................................................................................41 table 4Recommended Inter-Frequency Hard Handover Time-to-Trigger Settings for Different Movement Speeds..........................................................................................................................................................42
List of Figures
Figure 1 Measurement Model.........................................................................................................................8 Figure 2 Example of Event 1A and Trigger Delay.......................................................................................10 Figure 3 Periodic Reporting Triggered by Event 1A....................................................................................10 Figure 4 Example of Event 1C......................................................................................................................11 Figure 5 Example of Event 1D......................................................................................................................12 Figure 6 Restriction of measurement reporting by means of hysteresis.......................................................12 Figure 7 Example of Event 1E......................................................................................................................13 Figure 8 Example of Event 1D1F.................................................................................................................13 Figure 9 Power Control Timing....................................................................................................................22 Figure 10 MML Client .................................................................................................................................26
11-8-23
Confidential
Page 5 of 52
Key words: handover algorithm, soft handover, hard handover, inter-system handover, parameter setting Abstract: This document first describes the measurements involved in the handover algorithms, and then analyzes the measurement control and decision rules in the implementation of the algorithm of each type of handover. Finally, it provides a detailed guidance for the setting of various types of handover parameters, so that correct and effective handover parameter adjustments can be carried out based on the actual requirements during network optimization. List of abbreviations: (Omitted)
11-8-23
Confidential
Page 6 of 52
1 Introduction
Handover types include softer handover, soft handover, intra-frequency hard handover, inter-frequency hard handover and inter-system hard handover. A typical handover process is: measurement control measurement report handover decision handover execution new measurement control. Based on the measurement value, handover control method and handover type selection required for the handover decision, the handover algorithm determines how the UE carry out handover measurements and report the measurement result, and then makes handover decision and guides the handover execution according to the reported measurement result. Handover algorithms largely present themselves in the configuration of measurement control parameters. In Chapter 2, this document discusses the measurement control, reporting rules and related handover decision algorithms involved in various types of handover. In Chapter 3, based on the knowledge of the handover algorithms, this document provides detailed descriptions of the specific parameter setting methods value assignment recommendations and ranges of effect of the related algorithms of various types of handover, so as to provide a clear and practical guidance for parameter adjustments in network optimization.
11-8-23
Confidential
Page 7 of 52
relation and implemented weighted averaging processing of the measurement result. The latest measurement result after L3 filtering is used for evaluation of the reporting rule, and as the reported result. The process is as follows:
Parameter
Parameter
L1 filtering
L3 filtering
C C'
Figure 1
Measurement Model
The reporting types include on-demand reporting, periodic reporting and event triggered reporting (Event A to Event F). Generally, the last two types of measurement reporting are involved in handover. In the UE, measured cells are divided into the following three types:
Active set cells: Cells in an active set communicate with the UE simultaneously. Active set cells refer to those that are demodulated and correlatively combined at the UE and communicate with the UE in the FDD mode, namely in soft handover and softer handover. Cells in an active set are surely intra-frequency cells.
Monitored set cells: Among the cells included in the adjacent cell list delivered by the RNC, some adjacent cells may have already entered the active set at the time of soft handover, and the remaining cells are in monitored sets. Monitored sets include intra-frequency monitored sets, inter-frequency monitored sets and inter-system monitored sets.
Detected set cell: Detected set cells refer to those cells detected by the UE itself, rather than the cells in the active sets and monitored set. The types of measurement involved in handover include intra-frequency measurement,
inter-frequency measurement and inter-system measurement, which will be discussed in the following paragraphs.
1A while the UE has entered the Cell_DCH state, then when a primary pilot channel enters the reporting range, the UE will send a measurement report. When the measurement values satisfy the following formulas, the UE deems that a primary pilot channel has entered the reporting range:
1. Path loss:
10 LogM New
10 LogM New
Where, MNew is the measurement result of the cell that has entered the reporting range Mi is the measurement result of the cells in the active set NA is the number of cells in the current active set MBest is the measurement result of the best cell in the current active set W is the weight factor R is the reporting range. With the signal strength as an example, R equals to the signal strength of the best cell in the current active set minus a value H1a is the hysteresis value of event 1A In order to reduce the signaling traffic flow of the measurement report, the TIME-TOTRIGGER parameter is used so that the UE will not trigger measurement reporting before the primary pilot enters the reporting range and is maintained for a certain period of time. This parameter is also used in other events. An example of measurement reporting triggered by event 1A is given below:
P CPICH 2
P CPICH 3
Time-to-trigger
Reporting event 1A
Time
11-8-23
Confidential
Page 9 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Figure 2 Example of Event 1A and Trigger Delay
Generally, if event 1A is triggered, the UE will send a measurement report to UTRAN, and UTRAN will deliver an ACTIVE SET UPDATE signaling message to update the active set. However, UTRAN may give no response after the UE sends the measurement report (for example, due to insufficient capacity). In this case, the UE will shift from event reporting to periodic reporting mechanism, and the content of the measurement report includes the information of the cells in the active set and the cells in the monitored set that has entered the reporting range. The UE will not stop sending periodically the measurement report until this cell is successfully added into the active set or leaves the reporting range, as shown below:
P C P IC H 1
P C P IC H 2 R e p o r t in g ra n g e R e p o r t in g t e r m in a t e d P e r io d ic re p o rt E v e n t - t r ig g e r e d re p o rt P e r io d ic re p o rt P C P IC H 3
Figure 3
Event 1B: A primary pilot channel leaves the reporting range When the following formulas are satisfied, the UE deems that a primary pilot channel has left the reporting range 1, Path loss:
10 LogMOld
11-8-23
Confidential
Page 10 of 52
MBest is the measurement result of the best cell in the current active set W is the weighted factor R is the reporting range H1a is the hysteresis value of event 1A If several cells satisfy the reporting condition simultaneously after the trigger delay, the UE will sort the cells according to the measurement values and report all the measurement results. Event 1C: The primary pilot channel in a non active set is better than the primary pilot channel in an active set This event can be described through the following example:
Measurement quantity P CPICH 1
P CPICH 2 P CPICH 3
P CPICH 4
Reporting event 1C Reporting event 1C
Time
Figure 4
Example of Event 1C
In this example, the cells where P CPICH 1, P CPICH 2 and P CPICH 3 are belong to an active set, while that of P CPICH 4 does not. This event is used to replace the poor cells in the active set, if the number of cells in the active set reaches or exceeds active set replacement threshold. Event 1D: The best cell changes
11-8-23
Confidential
Page 11 of 52
P CPICH 2
P CPICH3
Reporting event 1D
Time
Figure 5
Example of Event 1D
In order to prevent frequent triggering of event 1D due to signal fluctuations when the channel difference is small, which results in unnecessary increase of the air interface signaling traffic flow, we can use the hysteresis parameter, as shown below:
P CCPCH 2 Hysteresis
Reporting event 1D
Time
Figure 6
As we can see, as the hysteresis condition is not met at the second time, event 1D reporting is not triggered. This parameter can also be used in other events.
Event 1E: The measurement value of a primary pilot channel exceeds the absolute threshold
11-8-23
Confidential
Page 12 of 52
P CPICH 3
Reporting event 1E
Time
Figure 7
Example of Event 1E
Event 1E can be used to trigger the measurement reports of cells including those detected by the UE before it receives the adjacent cell list.
Event 1F: The measurement value of a primary pilot channel is lower than the absolute threshold
Reporting event 1F
Time
Figure 8
11-8-23
Confidential
Page 13 of 52
NA j = W j 10 Log M i i =1
+ (1 W j ) 10 LogM Best j H ,
Qcarrierj is the logarithmic form of the estimated quality value of frequency j Mcarrier j is the estimated quality value of frequency j Mi j is the measurement result of cell i with the frequency of j in the virtual active set NA j is the number of cells with the frequency of j in the virtual active set MBest j is the measurement result of the best cell with the frequency of j in the virtual active set Wj is the weight factor H is the hysteresis value Before we describe events 2x, we should make the following two concepts understood: non-used frequency refer to the frequency that the UE needs to measure but that is not in the active set, and used frequency refers to the frequency that the UE needs to measure and that is in the active set.
Event 2A: The best frequency changes If the estimated quality value of the non-used frequency is better than that of the best cell in the used frequency, and the hysteresis value and the time to trigger conditions are satisfied, event 2A will be triggered. Event 2B: The estimated quality value of the used frequency is lower than a certain threshold, and that of the non-used frequency is higher than a certain threshold If the estimated quality value of the used frequency is lower than the threshold defined by IE Threshold used frequency delivered in the measurement control message, while that of the non-used frequency is higher than the threshold defined by IE Threshold non-used frequency delivered in the measurement control message, and the hysteresis value and the time to trigger condition are satisfied, event 2B will be triggered. Event 2C: The estimated quality value of the non-used frequency is higher than a certain threshold This threshold is specified by IE Threshold non-used frequency in the measurement control message delivered by UTRAN. Event 2D: The estimated quality value of the used frequency is lower than a certain threshold Event 2D can be used to enable the compressed mode to perform inter-frequency measurement. This threshold is specified by IE Threshold used frequency in the measurement
11-8-23
Confidential
Page 14 of 52
control message delivered by UTRAN. This type of parameters can be modified through MML commands. Event 2E: The estimated quality value of the non-used frequency is lower than a certain threshold This threshold is specified by IE Threshold non-used frequency in the measurement control message delivered by UTRAN. Event 2F: The estimated quality value of the used frequency is higher than a certain threshold Event 2F can be used to disable the compressed mode to stop inter-frequency measurement. This threshold is specified by IE Threshold used frequency in the measurement control message delivered by UTRAN.
QUTRAN = 10 LogMUTRAN
Where, QUTRAN is the logarithmic form of the estimated quality value of the UTRAN frequency currently in use MUTRAN is the estimated quality value of the UTRAN frequency currently in use Mi is the measurement result of cell i in the active set NA is the number of cells in the active set MBest result is the measurement result of the best cell in the active set W is the weight factor Event 3A: The estimated quality value of the used UTRAN frequency is lower than a certain threshold, and that of the other system is higher than a certain threshold If the estimated quality value of the used UTRAN frequency is lower than the threshold defined by IE Threshold own system delivered in the measurement control message, while that of the other system is higher than the threshold defined by IE Threshold other system delivered in the measurement control message, and the hysteresis value and the time to trigger condition are satisfied, event 3A will be triggered. Event 3B: The estimated quality value of the other system is lower than a certain
11-8-23
Confidential
Page 15 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance threshold
This threshold is specified by IE Threshold other system in the measurement control message. Event 3C: The estimated quality value of the other system is higher than a certain threshold This threshold is specified by IE Threshold other system in the measurement control message. Event 3D: The best cell in the other system changes
1) When either event 1A or event 1E (referred to as 1A or 1E) is satisfied, it will be deemed as the trigger condition for adding a soft handover branch;
11-8-23
Confidential
Page 16 of 52
2) After event 1A or 1E is received, if the number of cells in the active set is 3, no processing will be implemented. 3) When neither the relative threshold nor the absolute threshold (event 1B and 1F) is satisfied, it is deemed as the trigger condition for removing a soft handover branch. 4) If handover is triggered when either event 1B or event 1F is received, but the triggered cell is the best cell, then no processing will be made. 5) When the UE active set is full, event 1A and event 1E reporting is stopped, and event 1C reporting starts 6) Event 1C is the trigger condition for cell replacement in the active set. 7) Event 1D occurs in the active set cell, and measurement control changes, based on the best cell operation algorithm. 8) Event 1D occurs in the monitored set cell, and this cell is added into the active set. If the active set is full, remove any cell among non-best cells and then add the reported best cell, and mark it as the best cell. After successful operation, the measurement control change process is started.
2.
1) When event 1A report is received, if the active set is not full, then links are sequenced and added in the order of good quality to poor quality (CPICH Ec/No) (in case that multiple cells report event 1A), until the active set is full; if the active set is already full, no processing will be made. 2) When event 1B is received, if there are more than one links in the active set, then the braches are sequenced and removed in the order of poor quality to good quality (CPICH Ec/No) (in case that multiple cells report event 1B), until only one link is left; if there is only one in the active set, no processing will be made. 3) In case of event 1C, the UE will report the replacing and replaced cells in the event trigger list. If the active set is not full, then the triggered cell link will be added; if the active set is already full at this moment and the replaced cell is not the best cell in the active set, then this cell link will be removed. 4) In case of event 1D, if the triggered cell is an active set cell, then it will be marked as the best cell and measurement control is updated; if the triggered cell doe not belong to the active set, then this cell link will be added (if the active set is full, one of the non-best cell will be removed before this link is added) and marked as the best cell, with measurement control updated.
11-8-23
Confidential
Page 17 of 52
11-8-23
Confidential
Page 18 of 52
CPICH Ec/No or RSCP measurement quantity and thresholds will be adopted respectively according to the location property of the best cell in the active set (carrier coverage center or carrier coverage verge as previously described). If the measurement quantity is lower than the enabling threshold , event 2D will be reported, and inter-frequency measurement will be enabled through decision; if the active set quality rises and becomes higher than the disabling threshold, then event 2F reporting will be triggered and inter-frequency measurement will be stopped. 3. Inter-frequency hard handover decision Presently, the periodic measurement reporting mode is used for inter-frequency measurement. In RNC V1.2, the absolute threshold decision method based on cell properties is used for inter-frequency handover decision. According to different cell properties (carrier coverage verge cell and carrier coverage center cell), different physical measurement quantities (CPICH RSCP and CPICH Ec/No) and handover thresholds are used for handover decision. Based on the inter-frequency measurement result periodically reported by the UE, if the measurement values exceed the absolute threshold and the hysteresis values and the time to trigger condition is met, then the RNC will implement inter-frequency hard handover with the reported cell as the handover target cell. Note: Due to lack of a special compressed mode control policy, it is recommended that inter-frequency handover be used only for necessary handover caused by discontinuous carrier coverage. In this case, we can consider to enable the compressed mode only at the carrier coverage verge, while disable the compressed mode at the carrier coverage center by means of parameter configuration (by setting the absolute threshold of event 2D to the minimum) to disable inter-frequency hard handover.
11-8-23
Confidential
Page 19 of 52
4) For inter-system handover, CPICH RSCP is used as the physical measurement quantity and events 2D and 2F are used to decide enabling or disabling the compressed mode. 5) For inter-system handover, three compressed mode style sequences are used for concurrent measurement of GSM RSSI, BASIC identification and BASIC reconfirm, and the configuration of parameters is oriented to the cell type, namely, the parameters can be selected and configured based on the cell characteristics and user mobility statistics characteristics. 6) Periodic measurement reports are used for inter-system handover, and the RNC decides whether to implement hard handover according to the measurement reports.
11-8-23
Confidential
Page 20 of 52
(2) UEs with inconsistent SRNC and CRNC are not selected, because this kind of transfer involves signaling interworking on the Iur interface, while the Iur is an open interface, without this type of signaling. Upon receiving the load transfer signaling, the handover entity first implements handover decision to judge whether the two conditions previously mentioned are satisfied. If so, it will proceed with the next step of processing; otherwise, it will reject the request and indicate the reason.
11-8-23
Confidential
Page 21 of 52
DL DPCCH at UTRAN
PILOT
Data1
T TF P CI C
Data2
PILOT
T Data1 P C
DL DPCCH at UE
PILOT
Data1
UL DPCCH at UE
TFCI
TPC
PILOT
UL DPCCH at UTRAN
*1,2 *3
PILOT
The SIR measurement periods illustrated here are examples. Other ways of measurement are allowed to achieve accurate SIR estimation. If there is not enough time for UTRAN to respond to the TPC, the action can be delayed until the next slot.
Figure 9
As illustrated in the diagram, when the UE complete receiving the downlink PILOT bit, it has the time of 512 chips to generate the TPC bit for downlink power control according to the PILOT bit. When the UE is in the soft handover state, the generation of the TPC bit should be based on the PILOT calculation of all links. However, in the actual system, because the selection of the downlink transmission time is obtained by the NodeB based on the RNC-configured frame offset and code offset after roundup by 256 chips (the minimum time resolution of the NodeB is 256 chips), there is an error of 128 chips between the actual transmission time and the RNCconfigured time. Plus errors in the UE movement speed and clock drift, there will be an error of (128+20) chips at the UE side. That is, when the Rx-Tx time difference is within the range of 1024148 chips, the design of UE and NodeB should be able to satisfy the 1-slot power control requirement; when it is out of this range, the system will be unable to guarantee the 1-slot power control requirement, resulting in power control performance deterioration. The UE Rx-Tx time difference is measured once every 10 frames. When the Rx-Tx time difference is smaller than 876 (1024148) chips, the UE-end processing time will be reduced, and, as result, it will be likely that the downlink 1-slot power control cannot be guaranteed; when the Rx-Tx time difference is greater than 1172 (1024+148) chips, the NodeB-end processing will be reduced, and it will be likely that the uplink 1-slot power control cannot be guaranteed.
11-8-23
Confidential
Page 22 of 52
There are two UE internal measurement events for the measurement of the protocolprovided synchronization maintenance information: event 6F and event 6G, as described previously. Algorithm description: a) After the UE enters the CELL_DCH state, the algorithm enables the UE to report event 6F and event 6G through measurement control. b) The thresholds, delays and hysteresis values of events 6F and 6G are used as algorithm parameters, which can be adjusted through background configuration. c) Once event 6F or event 6G occurs on a radio link, the network side will release this radio link. D) The cell with its link released may retrigger other events and then new RL could be added to the active set.
11-8-23
Confidential
Page 23 of 52
(3) When the UE initiates an RRC setup requests, if the connection setup fails, the RNC will choose a new cell with the best quality for a further access attempt based on the cell measurement information in the RACH measurement report carried in the RRC CONNECTION REQUEST message, until all the available cells (candidate cells) fail and the number of attempts reaches the maximum retry times. (4) Candidate cells are picked up as follows: 1) Read the current system time, calculate the buffering time of the cell measurement value, and discards the cells of which the buffering time is bigger than MaxRelatingTime 2) Based on the measurement value in the buffered RACH report and the LinearFactor, convert the estimated value of the current cell signal quality: cell measurement value (CPICH Ec/No) buffer time (s) LinearFactor (dB/s) 3) Put the cells of which the estimated quality value is greater than DRDCSThreshold into the candidate set of the direct retry algorithm. (5) Retry with the cell having the best estimated quality from the candidate set cells. If retry fails, continue to retry, until the number of attempts reaches the maximum retry times (DRMaxNumber).
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance 2. Control method based on all the cells in the active set
A control method that can take the adjacent cells of all the cells in the active set is a good policy. The adjacent cell list is generated by means of the following method: Step 1: Add active set cells; Step 2: Add the common adjacent cells of the cells of all the active sets (3 active sets) into the adjacent cell list. If there are more than 32 adjacent cells after this action, remove randomly cells added in this step; Step 3: Add the common adjacent cells of every two active set cells into the adjacent cell list. If there are more than 32 adjacent cells after this action, remove randomly cells added in this step; Step 4: Consider adding the common adjacent cells of each active set cell into the adjacent cell list, starting from the adjacent cells of the best cell. If there are more than 32 adjacent cells after this action, remove cells by starting from the worst cell. Note: The RNC V1.2 version supports the adjacent cell list control method based on the best cell.
11-8-23
Confidential
Page 25 of 52
Figure 10 MML Client According to the functioning scope, handover algorithm parameter configuration commands are divided into categories: RNC-oriented global parameter configuration and cell-oriented parameter configuration. Handover common parameter configuration is RNC-oriented global parameter setting. Both RNC-oriented setting commands and cell-oriented setting commands are available for the configuration of intra-frequency handover measurement algorithm parameters, interfrequency handover measurement algorithm parameters and inter-system handover measurement algorithm parameters. Generally, the adjustments of these parameters during network optimization are all cell-oriented settings, while RNC-oriented global parameter configuration commands facilitate modification of whole-network handover parameters. For one same parameter, the cell-oriented command has higher priority.
3.2 Handover Common Parameters 3.2.1 Maximum Number of Cells in Active Set
Definition MaxCellInActiveSet, maximum number of cells in the active set
11-8-23
Confidential
Page 26 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Scope Per RNC Range and unit Integer(1..3) Working range Integer(1..3) Recommended value 3 Balance in setting Modification of value is not recommended. Modification/query
To configure this RNC-oriented global handover parameter, use the command set hocomm; to view the current configuration of the parameter, use the command lst hocomm.
11-8-23
Confidential
Page 27 of 52
RxTxtoTrig6F, the trigger threshold of event 6F. Namely, if the time interval between the UEs downlink receiving and the corresponding uplink transmission is greater than this absolute threshold, event 6F will be triggered. Scope Per RNC Range and unit Integer(768..1280), chip. Working range Integer(1024..1280)chip Recommended value 1172 Balance in setting The value of this parameter should not be too close to 1024; otherwise radio links will be removed too early. It is recommended that this parameter be adjusted within the range of 11723 chips. To guarantee the 1-slot power control, decrease the value of this parameter; otherwise, it could be increased. Modification/query To configure this RNC-oriented global handover parameter, use the command set hocomm; to view the current configuration of the parameter, use the command lst hocomm.
11-8-23
Confidential
Page 28 of 52
To configure this RNC-oriented global handover parameter, use the command set hocomm; to view the current configuration of the parameter, use the command lst hocomm.
11-8-23
Confidential
Page 29 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Enum(D8,D32,D64,D128,D144,D256,D384) Recommended value D64. Balance in setting
It is the rate decision threshold deciding whether soft handover is to be implemented for the BE service. When the maximum rate of the BE service transmission channel is smaller than this threshold, the system will perform soft handover for the service user so as to ensure the QoS for the user; when the maximum rate of the BE service transmission channel exceeds this threshold, the system will implement intra-frequency hard handover for the service user so as to prevent excessive influence on the system capacity caused by soft handover. Modification/query To configure this RNC-oriented global handover parameter, use the command set hocomm; to view the current configuration of the parameter, use the command lst hocomm.
11-8-23
Confidential
Page 30 of 52
11-8-23
Confidential
Page 31 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Compressed mode Off (0) Uplink compressed mode On (1) 6G & 6Fmeasurement Off (0) Cell penalty Off (0) Location On (1) RTT enhanced location Off (0) Relocation Off (0) Relocation based on time delay optimization Off (0) Relocation based on Iur transmission resource optimization Off (0)
CS UE relocation based on Iur transmission resource optimization Off (0) Direct retry Off (0) Balance in setting Corresponding configuration should be carried out based on the implementation of each version of algorithm. 1) Test compressed mode: compressed mode switch should be enabled. 2) Test inter-frequency hard handover: inter-frequency hard handover + compressed mode switch should be enabled. 3) Test inter-system hard handover : inter-system handover enabled + compressed mode switch should be enabled. 4) Test relocation: relocation enable switch a main switch. When the main switch is off, the following three will not function Relocation based on time delay optimization enable switch Relocation based on Iur transmission resource optimization enable switch CS UE relocation based on Iur transmission resource optimization enable switch Modification/query For RNC-oriented settings, use the command set/lst corrmalgoswitch.
3.3 Intra-Frequency Handover Measurement Algorithm Parameters 3.3.1 Soft Handover Relative Thresholds
Definition These parameters define the difference between the quality of a cell (currently it is evaluated with PCPICH Ec/No) and the overall quality of the active set (if w=0, then it is the quality of the best cell). The relative threshold parameters for soft handover include IntraRelThdFor1A (relative threshold for event 1A) and IntraRelThdFor1B (relative threshold for event 1B). Scope
11-8-23
Confidential
Page 32 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Per RNC/CELL Range and unit Integer(0~29), corresponding to 0 to 14.5dB; configuration step: 1 (0.5dB). Working range Integer(0~16) Recommended value 10, namely, 5dB. Balance in setting
Settings of these parameters determine the size of the soft handover area and the soft handover subscriber proportion. In a CDMA system, it is required that the UE proportion in soft handover should be 30% to 40% so as to ensure smooth handover. Based on the simulation result, when the relative thresholds are set at 5dB, the proportion of UEs in the soft handover state (number of active set cells 2) is around 35%. It is recommended that this value be slightly bigger in the early stage of deployment (5 to 7dB). To save system resources, this figure can be gradually decreased with the growth of the number of subscribers, but it must be bigger than 3dB. The default configuration is 5dB. In addition, in special applications, different relative threshold values can be set for event 1A and event 1B to reduce the ping-pong effect and change the soft handover proportion in some special applications. For example, if the adjustment of the hysteresis values for events 1A and 1B is insufficient for good control of the ping-pong effect, the relative threshold for event 1B can be set larger than that for event A to reduce the ping-pong effect. However, the relative thresholds for events 1A and 1B should generally be kept consistent; instead, the time-to-trigger setting, L3 filter coefficient and hysteresis value should used to reduce the ping-pong effect. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellintrafreqho. Otherwise, use the RNC-oriented global settings configured with the command set intrafreqho as the configuration for the concerned cell.
11-8-23
Confidential
Page 33 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Working range Integer(-20..-10)dB Recommended value -18. Balance in setting
This value is the absolute threshold value used in the measurement reports of events 1E and 1F in the soft handover algorithm, corresponding to the signal strength that satisfies the basic QoS assurance. This value affects the trigger of events 1E and 1F. Because an absolute threshold is only a necessary condition, but not a sufficient one, for access judgment, this value should be relative loose. With value settings in IS-95 and the lower threshold of -20dB, -18dB is deemed to be a reasonable value. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellintrafreqho. Otherwise, use the RNC-oriented global settings configured with the command set intrafreqho as the configuration for the concerned cell.
Fn = (1 a ) Fn 1 + a M n
Where, Fn: the updated measurement result after filtering processing. Fn-1: the old measurement result of the previous moment after filtering processing. Mn: The latest measurement value received from the physical layer. a = (1/2)(k/2), where, k is from IE "Filter coefficient", namely FilterCoef here. When k=0
11-8-23
Confidential
Page 34 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance and a=1, L3 filtering is not implemented.
According to R2-000809, we recommend that the commonly used value of the filter coefficient be in the range of {0,1,2,3,4,5,6}. The bigger the filter coefficient is, the stronger the burr filtering capability will be, but the weaker the signal tracking capability will be. Therefore, a balance must be made. Calculated based on the typical handover area size [3], the distance between two NodeBs is 1000m, while calculated based on the 40%soft handover ratio of the entire system, the typical handover distance between two cells is about 150m. A mobile station that is moving at the speed of 20km/h goes across the handover area in averagely 20 to 30 seconds, while it takes only 5 to 6 seconds for a mobile station that is moving at the speed of 100km/h to go across the handover area. When such factors as hysteresis and trigger delay in event judgment are taken into account, the tacking time needs to be further reduced. Based on the analysis above, FilterCoef should be configured as follows: 5 as the default setting for intra-frequency filter coefficient, and this parameter can be adjusted according to the actual situation. In addition, for different cell coverage types, typical values are recommended as follows: a, if the cell covers urban area, the intra-frequency filter coefficient can be 7; b, if the cell covers suburbs, the intra-frequency filter coefficient can be 6; c, if the cell covers rural area, the intra-frequency filter coefficient can be 3. Table 1
Filter coefficient Iteration times
11 85
10
15
21
30
42
The table above lists the iteration times required when different filter coefficients are used to obtain 85% of the final output value. According to 25.133, in the CELL_DCH state, L1 reports the intra-frequency measurement result to L3 at a cycle of 200ms. When the iteration times are substituted with Intra-frequency tracking time, the table above will become: Filter coefficient Intrafrequency tracking time (s)
0 1 2 3 4 5 6 7 8 9 11
0.2
0.4
0.6
1.4
4.2
8.4
17
Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellintrafreqho. Otherwise, use the RNC-oriented global settings configured with the command set/lst intrafreqho as the configuration for the concerned cell.
11-8-23
Confidential
Page 35 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Definition
Hysteresis for event triggering, including Hystfor1A, Hystfor1B, Hystfor1C, Hystfor1D, Hystfor1E and Hystfor1F Scope Per RNC/CELL Range and unit Integer(0..15) , corresponding to 0..7.5dB; configuration step 1(0.5dB) Working range table 1 Recommended Soft Handover Hysteresis Settings for Different Movement Speeds Speed (km/h) 5 50 120 Typical configuration Recommended value 6(3dB) for events 1A and 1E, and 8(4dB) for events Balance in setting For UEs entering the soft handover area, increase of the hysteresis value means decrease of the soft handover range, while for UEs leaving the soft handover area, it means increase of the soft handover range. If the number of UEs entering the handover area is the same as the number of UEs leaving the handover area, there will be no influence on the actual soft handover proportion. The bigger the hysteresis value is, the stronger the signal fluctuation resistance capability will be, and thus the better the ping-pong effect will be suppressed, but the slower the handover algorithm can react on signal changes. Therefore, in the setting of this parameter, not only the radio environment (slow fading characteristic) but also the actual handover distance and the UE movement speed should be taken into due consideration. The setting of this parameter can be adjusted within the range of 2 to 5dB. As events that add cells to the active set, 1A and 1E are critical events. In order to ensure timely handover, the hysteresis value for event 1A can be smaller, but not be too smaller, than those for 1B, 1F, 1C and 1D; otherwise, the soft handover proportion will be affected. In addition, In addition, hysteresis adjustment should generally be considered together with the filter coefficient and time-to-trigger settings. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellintrafreqho. Otherwise, use the RNC-oriented global settings configured with the command set intrafreqho as the configuration for the concerned cell. Range 6~10(3~5dB) 4~10(2~5dB) 2~6(1~3dB) 4~10(2~5dB) Recommended Value 10(5dB) 6(3dB) 2(1dB) 6(3dB)
11-8-23
Confidential
Page 36 of 52
11-8-23
Confidential
Page 37 of 52
handover and mis-handover and do have produce remarkable influence on the call drop rate. For the latter type of events, the time-to-trigger setting can be properly big. For events that remove cells from the active set (event 1Band event 1F), the time-to-trigger value is set mainly to reduce ping-pong handover; the initial setting can be the same as that for event 1A and event 1E, and can be properly adjusted based on the actual network statistics result. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellintrafreqho. Otherwise, use the RNC-oriented global settings configured with the command set intrafreqho as the configuration for the concerned cell.
3.3.6 WEIGHT
Definition Weighted factor (see formulas on Section 2.1.1) Scope Per RNC/CELL Range and unit Integer(0..20), corresponding to 0..2; step: 0.1 Working range Integer(0..10) Recommended value 10, namely 1 Balance in setting This parameter is used to determine the soft handover relative threshold based on the measurement value of each cell in the active set. The bigger this parameter is, the higher the relative threshold obtained under the same condition will be. When W=0, the determination of soft handover relative threshold is related to only the best cell in the active set. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellintrafreqho. Otherwise, use the RNC-oriented global settings configured with the command set intrafreqho as the configuration for the concerned cell.
11-8-23
Confidential
Page 38 of 52
DetectStatSwitch, used to control whether the UE measurement report contains the information of cells in the detected set, so as to provide statistics data for future network optimization. Scope Per RNC/CELL Range and unit Enum(ON, OFF) Working range Enum(ON,OFF) Recommended value OFF Balance in setting In the beginning of network operation, when you are not absolutely sure about the adjacent cell configuration, this switch can be set to ON so that missed adjacent cells can be detected and thus handover can be smoothly implemented. After network optimization, this switch can be set to OFF. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellintrafreqho. Otherwise, use the RNC-oriented global settings configured with the command set intrafreqho as the configuration for the concerned cell.
3.4 Inter-Frequency Handover Algorithm Parameters 3.4.1 Inter-Frequency Measurement Filter Coefficient (FilterCoef)
Definition The measurement smoothening coefficient used in L3 filtering of inter-frequency measurement report Scope Per RNC/CELL Range and unit Enum(D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D11, D13, D15, D17, D19), corresponding to (0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19) Working range Enum(D0, D1, D2, D3, D4, D5, D6, D7, D8) Recommended value D5, namely 5 Balance in setting The following formula is used for the calculation of measurement value filtering:
11-8-23
Confidential
Page 39 of 52
Fn = (1 a ) Fn 1 + a M n
Where, Fn: the updated measurement result after filtering processing. Fn-1: the old measurement result of the previous moment after filtering processing. Mn: The latest measurement value received from the physical layer. a = (1/2)(k/2), where, k is from IE "Filter coefficient", namely FilterCoef here. When k=0 and a=1, L3 filtering is not implemented. According to R2-000809, we recommend that the commonly used value of the filter coefficient be in the range of {0,1,2,3,4,5,6}. The bigger the filter coefficient is, the stronger the burr filtering capability will be, but the weaker the signal tracking capability will be. Therefore, a balance must be made. For different cell coverage types, typical values are recommended as follows: a, if the cell covers urban area, the inter-frequency filter coefficient can be 7; b, if the cell covers suburbs, the inter-frequency filter coefficient can be 6; c, if the cell covers rural area, the inter-frequency filter coefficient can be 3. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellinterfreqho. Otherwise, use the RNC-oriented global settings configured with the command set interfreqho as the configuration for the concerned cell.
11-8-23
Confidential
Page 40 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance measurement object for event 2D and event 2F. Modification/query
11-8-23
Confidential
Page 41 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Scope Per RNC/CELL Range and unit
Enum(D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000), corresponding to (0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000)ms The value range of TrigTimeHHO is 0 to 64000ms Working range Enum(D0, D200, D240, D640, D1280, D2560, D5000) Recommended value table 4 Recommended Inter-Frequency Hard Handover Time-to-Trigger Settings for Different Movement Speeds Speed (km/h) 5 50 120 Typical configuration Balance in setting Range (ms) 640, 1280 240, 640 240, 640 640, 1280 Recommended value (ms) 1280 640 640 640
Simulation shows that the setting of the hysteresis value can effectively reduce the average handover times and mis-handover times, and thus can prevent the occurrence of unwanted handover. The bigger the hysteresis value is, the less the average handover timers will be. However, the increase of the hysteresis value will bring more risks of call drop. It is stipulated in TS 25.133V3.6.0 that the physical layer of intra-frequency measurement updates the measurement result every 200ms. Therefore, a time-to-trigger value below 200ms does not make any practical sense, and it should be as close as possible to an integral multiple of 200ms. In addition, simulation also shows that mobile stations moving at different speeds respond differently to the time-to-trigger value. The call drop rate is more sensitive to the time-to-trigger value when the mobile station is in highspeed movement, while it is less sensitive when the mobile station is in low-speed movement, and ping-pong handover and mis-handover are suppressed to a certain extent. Therefore, for cells where there are more high-speed moving mobile stations, this value can be relatively small, while for cells where there are more low-speed moving mobile stations, this value can be relatively big. The setting can be properly adjusted based on the actual network statistics result. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellinterfreqho. Otherwise, use the RNC-oriented global settings configured with the command set interfreqho as the configuration for the concerned cell.
11-8-23
Confidential
Page 42 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Definition
This parameter corresponds to the absolute thresholds for inter-frequency measurement events when RSCP is used as the measurement object, including InterThdUsedFreqFor2DRSCP (absolute threshold for event 2D) and InterThdUsedFreqFor2FRSCP (absolute threshold for event 2F) Scope Per RNC/CELL Range and unit Integer(-115..-25), dBm. Working range Integer(-115..-25)dBm Recommended value -95dBm Balance in setting Events 2D and 2F are the switches to enable/disable the compressed mode. When the cell is located the verge of carrier coverage, the RSCP measurement value will be used as the decision criterion for event 2D and event 2F. Therefore, if you hope to enable the compressed mod as early as possible, set a big value; otherwise, set a small value. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellinterfreqho. Otherwise, use the RNC-oriented global settings configured with the command set interfreqho as the configuration for the concerned cell.
11-8-23
Confidential
Page 43 of 52
Events 2D and 2F are the switches to enable/disable the compressed mode. When the cell is located the center of carrier coverage, the Ec/No measurement value will be used as the decision criterion for event 2D and event 2F. Therefore, if you hope to enable the compressed mod as early as possible, set a big value; otherwise, set a small value. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellinterfreqho. Otherwise, use the RNC-oriented global settings configured with the command set interfreqho as the configuration for the concerned cell.
11-8-23
Confidential
Page 44 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Per RNC/CELL Range and unit Integer(-24..0), dB. Working range Integer(-24..0)dB Recommended value -16dB Balance in setting
When Ec/No is used as the physical measurement quantity and the quality of the measure cell is higher than this threshold, this cell can be used as the target cell for inter-frequency hard handover. If this cell is located at the center of carrier coverage, the Ec/No measurement value will be used as the decision criterion for inter-frequency hard handover. If this value is too big, call drop is likely to occur due to failure of timely initiation of inter-frequency hard handover; if it is too small, it may result in excessively frequent verge hard handover or call drop after handover due to weak signals of the target cell. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellinterfreqho. Otherwise, use the RNC-oriented global settings configured with the command set interfreqho as the configuration for the concerned cell.
3.5 inter-system handover measurement algorithm parameter 3.5.1 inter-system measurement filter coefficient FilterCoef
Definition The measurement smoothening coefficient used in L3 filtering of inter-system measurement report Scope Per RNC/CELL Range and unit Enum(D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D11, D13, D15, D17, D19), corresponding to (0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19) Working range Enum(D0, D1, D2, D3, D4, D5, D6, D7, D8) Recommended value D4, namely 4 Balance in setting See Section 3.4.1. The bigger this parameter value is, the better the signal filtering effect will be, and the stronger the anti-fading capability will be, but the weaker the signal tracking
11-8-23
Confidential
Page 45 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance capability will be. Modification/query
To implement cell-oriented settings, use the commands add/mod/rmv/lst cellinterratho. Otherwise, use the RNC-oriented global settings configured with the command set interratho as the configuration for the concerned cell.
11-8-23
Confidential
Page 46 of 52
inter-system handover decision. This value can be properly decreased in areas with small shadow fading and properly increased in areas with big shadow fading. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellinterratho. Otherwise, use the RNC-oriented global settings configured with the command set interratho as the configuration for the concerned cell.
11-8-23
Confidential
Page 47 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Range and unit
Enum(D250, D500, D1000, D2000, D3000, D4000, D6000, D8000, D12000, D16000, D20000, D24000, D28000, D32000, D64000) ,corresponding to the physical range of (250, 500, 1000, 2000, 3000, 4000, 6000, 8000, 12000, 16000, 20000, 24000, 28000, 32000, 64000) ms Working range Enum(D250, D500, D1000, D2000, D3000, D4000, D6000, D8000, D12000, D16000, D20000, D24000, D28000, D32000, D64000) Recommended value D1000 Balance in setting If the value this parameter is too big, the measurement result may fail to be timely reported, and thus the best handover chance may be missed, resulting in handover failure. If the value of this parameter is too small, the measurement result will be frequently reported, resulting in increase of the signaling burden of the system. Modification/query To implement cell-oriented settings, use the commands add/mod/rmv/lst cellinterratho. Otherwise, use the RNC-oriented global settings configured with the command set interratho as the configuration for the concerned cell.
3.6 Compressed Mode Algorithm Parameter 3.6.1 CFN Offset to Enable Compressed Mode
Definition DeltaCFN. In order to ensure that the UE and the NodeB enable the compressed mode simultaneously, the delay of the compressed mode enabling moment in relation to the current processing moment should be preset. Scope Per RNC Range and unit Integer(0..255) , frame Working range Integer(0..255)frame Recommended value 80 Balance in setting The value of this parameter depends on the sum of the maximum delay in the transmission of signaling from the RNC to the UE and NodeB and hardware preparation
11-8-23
Confidential
Page 48 of 52
time required to start the compressed mode, and it is generally between 500 and 1500ms. In WCDMA, the duration of one frame is 10ms, so the recommended value of this parameter is between 50 and 150. Modification/query To configure this RNC-oriented global handover parameter, use the command set cmcf; to view the current configuration of the parameter, use the command lst cmcf.
3.7 Direct Retry Algorithm Parameter 3.7.1 Maximum Direct Retry Times
Definition DRMaxNumber, the maximum allowed retry times for the direct retry module after the initial failure, as described in Section 2.2.8. Scope Per RNC Range and unit
11-8-23
Confidential
Page 49 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Integer(1..5) Working range Integer(1..5) Recommended value 2 Balance in setting None Modification/query
To configure this RNC-oriented global handover parameter, use the command set drd; to view the current configuration of the parameter, use the command lst drd.
11-8-23
Confidential
Page 50 of 52
MinSignalRequired. The basic access threshold described in Section 2.2.8, namely the minimum requirement of the UE form the receiving CPICH Ec/No density during normal demodulation. Scope Per RNC/CELL Range and unit Integer(-19..0) Working range Integer(-19..0) Recommended value -18 Balance in setting In the direct retry algorithm, the cell signal measurement value in the RACH report must be higher than this threshold before the direct retry algorithm can consider this cell; otherwise the cells with poor signal quality will be neglected. This parameter and the candidate set absolute threshold can jointly prevent the occurrence of latter case mentioned above. Modification/query To configure this RNC-oriented global handover parameter, Use the command set drd; to view the current configuration of the parameter, use the command lst drd. Alternatively, use the command add/mod/lst/rmv celldrd to add/modify/remove cell-oriented parameter settings, which has a higher priority.
11-8-23
Confidential
Page 51 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance Modification/query
To configure this RNC-oriented global handover parameter, Use the command set drd; to view the current configuration of the parameter, use the command lst drd.
11-8-23
Confidential
Page 52 of 52
WCDMA RNO Handover Algorithm Analysis and Parameter Configuration Guidance List of references: [1] 3GPP R99 25_series, 2002/09 [2] Xie Zhibin, 3Ghandover planning, 2001/08
[3] Li Zhen, WCDMA RNC V100R002 RAA Handover Algorithm Requirement Specification, 2003/6 [4] Li Zhen, WCDMA RNC V100R002 RAA Handover Parameter Configuration Specification, 2003/10 [5] Zhou Xinjie, WCDMA RNP System Parameter Setting Guidance, 2003/04