You are on page 1of 4

Molded Case Circuit Breakers

SELECTION

MD 800A Frame Sentron Series


Type MXD6______________________
Continuous Current Rating @40C_____________ 500 600 700 800________________ ^-Po^ Catalog Number_____

Blue Label
^ List Price $

Ordering Information
Complete Breaker Unassembled with Lugs Pricing information for MD6 and HMD6 breakers includes frame, trip, and both line and load lugs (TA3K500). When ordered by these catalog numbers, the customer will receive the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of MXD6, HMXD6 and CMD6 include frame with noninterchangeable trip units installed only. Order required lugs separately. For line and load lugs (TA3K500) installed, add suffix "L" to catalog number (add 2 times list price of lugs for each pole). 100% Rated Types MXD6, HMXD6 and CMD6 breakers are available with 100% ratings. To order add suffix "H" to catalog number, and 10% to list price. 100% rated MD breakers require the use of 90C Cu cable and lugs TA4P8500 or TA2N8750. 50C Applications see page 1 1 1 . 400Hz Applications see pages
1 1 1 , 147.

Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs)_______


_______3-Pole______ List Price $ Catalog Number_____

MXD62B500 4891.00 MXD62B600 4891.00 MXD62B700 4891.00 IVIXD62B800_____4891.00

MXD63B500 6192.00 MXD63B600 6192.00 MXD63B7QO 6192.00 MXD63B800_____6192.00

Type MD6
Interchangeable Trip
Complete Breaker Unassembled with Lugs Catalog Number List Price $ Frame Only Catalog Number List Price S

I Blue Label"]
Trip Unit Only Catalog Number List Price S

1
CE I- UJ

Continuous Current Setting @40C

2-Pole 600V AC, 250V DC


500 600 700 800

<f>

MD62B500 MD62B600 MD62B700 MD62B800

5194.00 5194.00 5194.00 5194.00

MD62F800

2549.00

MD62T500 MD62T600 MD62T700 MD62T800

2341.00 2341.00 2341.00 2341.00

3-Pole 600V AC, 500V DC

II u in

500 600 700 800

MD63B500 MD63B600 MD63B700 MD63B800

6648.00 6648.00 6648.00 6648.00

MD63F800

3256.00

MD63T500 MD63T600 MD63T700 MD63T800

2936.00 2936.00 2936.00 2936.00

Lugs
Catalog Number TA2K500 TA3K500 TC2K500 TC3K350 Kits 2TA2N8750 3TA2N8750 2TA3N8750 3TA3N8750 2TA4N8500 3TA4N8500 2TA4P8500 3TA4P8500
1-2 1-3 1-4 1-4 2

Cables

Lugs

Per Lug
1-2 1-3 1-2 1-3

Per Kit
1 1 1 1

Wire Range #1-500 kcmil Cu/AI 1/0-500 kcmil Cu/AI #1-500 kcmil Cu #1-350 kcmil Cu

List Price EachS 56.00 76.00 94.00 119.00 286.00 402.00 452.00 652.00
461 .00 668.00

3
2 3 2 3 2 3

600-750 kcmil Cu/AI 500-750 kcmil Cu/AI 250-500 kcmil Cu/AI 250-500 kcmil Cu/AI

Shipping Weights
Number of Poles Number per Carton Shipping Weight (Ibs.) MD6, HMD6, HMXD6, CMD6 Complete Breaker Assembled (less lugs) 1 2
3

457.00 661.00

Instantaneous Adjustment Trip Range


Ampere Rating 500-600 700-800 Nominal Instantaneous Values L o w 3430 4570 2 3 4 5 6
5140 6850

53 61.5

1
1

MD6, HMD6 Frame Only 7 5570 7420 High 6000 8000

3000 4000

3860 ^4280 5140 5710

nw
6280

2 3

1 1 1

42.25 46
4.5 6.5

MD6, HMD6 Trip Unit Only


2 3

Enclosures
Type
1 3R 12

Catalog Number MND61 MND63 MND612 W63623

List Price $ 703.00 1726.00 2259.00 379.00

Neutral MXD6 circuit breakers are UL Listed for reverse connection applications. 2-pole units available in 3-pole width only Use 6 connectors for 3-pole, use 4 connectors for 2-pole. When wired as shown on page 39, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems. See Note: A, page 108. 80% rated breakers with the CE mark will also be marked in the 100% rated version Note: MD frame qualified to UL489 supplement B "NAVAL". See page 111 for additional information.

Modifications page 111 Enclosures pages 34-46 Accessories pages 108-126

Built to order. Allow 2 weeks for production.

Q Siemens Electrical Products SPEEDFAX 2000 l

Discount Schedule F

Molded Case Circuit Breakers


INTRODUCTION What's New?
With this Speedfax, Siemens Energy & Automation is proud to announce several new products. These new concepts serve the OEM and power distribution markets. CE Marking A wide range of Sentronthermal magnetic circuit breakers has been fully tested for compliance with the European community's Low Voltage Directive, and carry the CE mark, indicating their compliance with that directive. These are noted in the Speedfax with the stylized CE in watermark behind the catalog numbers. Declarations of conformity are available for these products. A point of misunderstanding lies in the area of handle operators. A handle operator alone, such as that for the Max-flex, since there is no applicable European Directive, may not carry the CE mark. The mark is affixed to the finished equipment that incorporates the handle, but not to this component device. Sensitrip Ammeter Display Unit sensing current is in the milliamp range, and the sensing voltage is 12 Volts or lower. These very reliable low level switches overcome that limitation. Standard switch contacts should, of course, continue to be used in standard current and voltage applications DIN Rail mounted 120/240 V Breaker Rotary Handle Operators for CQD

Both fixed and variable depth handle operators are available for the CQD breaker. These make the CQD a particularly attractive product for use in control panels and similar configurations Potter & Brumfield Discontinued With SE&A's divestiture of Siemens Electromechanical Components, we have ceased offering the Potter & Brumfield line of supplementary Protectors. Enhanced SB ICCB

The Siemens BO breakers are now available in 1-and 2-pole construction, from 15 to 60 Amps in lug in - lug out DIN rail mounted configuration. These breakers, rated 120/240 Volts, are ideal for applications in control panels and HVAC, and with their available finger safe terminal shields can qualify as service disconnects. QJ Walking Beam Interlock

The Ammeter display for the Sensitrip electronic trip family of breakers brings a new level of diagnostic capability even to non-interconnected breakers. Having an internal clock calendar, it can record the date and time of each trip event that occurs. Other products rely on being connected in a full network to time stamp events. This exclusive patented Siemens device provides current metering and breaker-trip diagnostic information without expensive networks. PLC Level Auxiliary Switches A new family of gold flashed auxiliary switches for the FD through ND breakers allows sensing at very low voltage and currents for interface directly to programmable logic controllers and other electronic devices. Standard contacts, built to switch 120 Volts and higher currents can be unreliable when the

Answering the growing need for 120/240 and 240 Volt standby power systems, Siemens introduces the walking beam interlock for the QJ family of 240 Volt circuit breakers. Useful in the cell tower and other commercial applications, the QJ walking beam allows interlocking two 2 pole beakers mounted using only 4 pole widths, or two 3 pole breakers using 6 pole widths. Please consult the factory for availability.

There have been several functional enhancements to the SB Systems Breaker since the last issue of the Speedfax. These include: . Improved reliability, including regular monthly breaker endurance testing to 8,000 operations, a new Electronic Motor Operator tested to 12,000 operations, and improved secondary disconnects . Extended 2 Year Standard Warranty

Siemens Electrical Products SPEEDFAX 2000

Molded Case Circuit Breakers


SELECTION /APPLICATION

Reference Guide
General Purpose Breakers LMD6, LMXD6 Page
D

HLMD6, HLMXD6
83 2,3

MD6, MXD6 84 2,3

HMD6, HMXD6
85 2,3

CMD6
85 3

ND6, NXD6 86 2,3

HND6, HNXD6
87 2,3

CND6
87 3

82

oles 2-Pole 3-Pole 240V


UL

2,3

Amperes, Continuous Volts 50/60 HZ

500-800
600

500-800
600

500-600
600

500-800
600

400-800
600

800-1200
600

800-1200
600

800-1200
600

65,000 50,000 25,000 65,000 33,000 40,000 20,000 30,000 15,000 30,000 25,000
16.00

100,000 65,000 25,000 100,000 50,000 65,000 33,000 42,000 21,000 30,000 50,000
16.00 7.50 4.59 y
v v

65,000 50,000 25,000 65,000 33,000 40,000 20,000 30,000 15,000 30,000 25,000
16.00 9.00 6.19 / J

100,000 65,000 50,000 100,000 50,000 65,000 33,000 42,000 21,000 30,000 50,000
16.00 9.00 6.19
v

200,000 100,000 65,000 200,000 100,000 100,000 50,000 65,000 33,000 30,000 50,000
16.00 9.00 6.19
y

65,000 50,000 25,000 65,000 33,000 40,000 20,000 30,000 15,000 30,000 25,000
16.00 9.00 6.19

100,000 65,000 50,000 100,000 50,000 65,000 33,000 42,000 21,000 30,000 50,000
16.00 9.00 6.19
y

200,000 100,000 65,000 200,000 100,000 100,000 50,000 65,000 33,000 30,000 50,000
16.00 9.00 6.19

480V 600V

AC
Ratings nterrupt Rating Symmetrical RMS Amperes IEC 947-2 50/60HZ

leu Ics
380/41 5V

Ics

500V

' Ics

CU

DC

2-Pole 250V DC Interrupting Ratings 3-Pole, 500V DC Interrupting Ratings Height 2-Pole 3-Pole

Dimensions in inches

Width Depth Thermal and Fixed Magnetic Trip Thermal and Adjustable Magnetic Trip Adjustable Magnetic Trip Only Motor Circuit Protector Molded Case Switch UndervoltageTrip Shunt Trip Auxiliary Switch Alarm Switch

7.50 4.59
v

Overcurrent Devices

__

y
y y ^
v

y
v

y
y<

v'

y
v

y
V*

y ^

y y y
v
V

y
v

y
V

y y
v

y y y

y
y
v

y
v

y
y ^

Accessories & Modifications

Mechanical Interlock Rear Connection Studs Electric Motor Operator Plug-In Mounting Assembly Fungus Proofing (ref. page 106) Type 1 Indoor Surface Type 1 Indoor, Flush

j
J y
v

y y v
x

y
y

^
y __

y
y

Individual Enclosures

Type 3R Outdoor-Rainproof Type 5, 12 Lint, Fine Dust, Oils, Coolants Type 7 Flammable Gas Atmosphere Type 9 Combustion Dusttight Type 12K Semi-Dusttight

y y y

y
y

y Y/ y
y j ^

v'

y __
y

y y
v v

y
v/
V

y \/ _

y ^

y
I ^

y y

y _ v/

y y v/

For DC UPS application. For inches / millimeters conversion, see Application Data section. 1!JB Siemens Electrical Products SPEEDFAX 2000

Molded Case Circuit Breakers


5^^^SSi^BSIBw^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^SiSis^SSiB++

SELECTION /DIMENSIONS Black Label

MD 800A Frame Sentron Series


Type HMXD6
2-Pole600VAC 250V DC Catalog Number HMXD62B500 HMXD62B600 HMXD62B700 HMXD62B800 List Price S 5889.00 5889.00 5889.00 5889.00
3 .p o|e 600VAC

Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs)


Continuous Current Rating @40C
500 600 700 800

500V DC Catalog Number HMXD63B500 HMXD63B600 HMXD63B700 HMXD63B800 List Price $ 7497.00 7497.00 7497.00 7497.00

Type HMD6
Interchangeable Trip
Continuous Current Rating @40C Complete Breaker Unassembled with Lugs Catalog Number List Price $ Frame Only Catalog Number List Price $

Black Label

Trip Unit Only Catalog Number List Price S

2-Pole 600V AC, 250V DC


500 600 700 800
HMD62B500 HMD62B600 HMD62B700 HMD62B800 6192.00 6192.00 6192.00 6192.00 HMD62F800 3547.00 MD62T500 MD62T600 MD62T700 MD62T800 2341.00 2341.00 2341.00 2341.00
w

r 1

-D1 D

r
ro o

NDTS Shield

3-Pole 600V AC, 500V DC


500 600 700 800

U ^

IH I
3 t/>

HMD63B500 HMD63B600 HMD63B700 HMD63B800

7952.00 7952.00 7952.00 7952.00

HMD63F800

4560.00

MD63T500 MD63T600 MD63T700 MD63T800

2936 00 2936.00 2936.00 2936.00

0
NDTS Shield

Type CMD6
Fuseless Current Limiting
2-Pole Continuous Current Rating @40C
500 600 700 800

Red Label
3-Pole 600V AC/500V DC Catalog Number For 2-pole application use outside poles of 3-pole circuit breaker CMD63B500 CMD63B600 CMD63B700 CMD63B800 List Price $ 11593.00 11593.00 11593.00 11593.00

Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs)


600V AC/250V DC

Lug

-^
(To Handle)

When wire lug shield NDTS is used.


No te NDTS lug shields are required when oversized lugs

are used The kits include the NDTS shield

Interrupting Ratings
UL 489 AIR File E10848 RMS Symmetrical Amperes (KA) Breaker Type MD6, MXD6 HMD6, HMXD6 CMD6 Volts AC
240 65 100 200 480 50 65 100 600 25 50 65

Dimensions (in inches)


Breaker Type MD6, MXD6, HMD6, HMXD6, CMD6, MXD6-ETI, CMD6-ETI with lug shields
W 9 9 L 16 24

IEC 947-2 AIR Volts AC (50/60HZ) 220/240 500


25 (3-P) 50 (3 P) 65 200 33 50 100

D
6 6

D1
825 825

Volts DC
250 30 (2 P) 30 (2-P) 30 (2-P)

380/415
40 65 100 20 33 50

500 30 42 65 15 21 33

(leu) (Ics) (leu) (Ics) (leu) (Ics

50 (3-P) 100

For inches / millimeters conversion, see Application Data section HMXD6 circuit breakers are UL listed for reverse connection applications

@2-pole units available in 3-pole width only MXD6 ETI, CMD6-ETI see page 106 for catalog information When wired as shown on page 39, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only

Built to order Allow 2 weeks for production

Discount Schedule F

Siemens Electrical Products SPEEDFAX 2000

^M

You might also like