You are on page 1of 5

Libraries in: C:\Users\Diego\02_ALEX Library

Library Search

-- BSC 08A08A 212 33 APG4033 BSC APZ APZ 212

APG40

rlmfc

BSC 08A APZ 212 33 APG40 Description Operation & Maintenance

COMMAND DESCRIPTION

1/190 82-CNT 240 1478 Uen E

RLMFC
Ericsson AB 2003-2004, 2006 - All Rights Reserved

Radio Control Cell, Measurement Frequencies, Change 1 Format


1.1 Command
RLMFC:CELL=cell,MBCCHNO=mbcchno...[,LISTTYPE=listtype] [,MRNIC];

1.2 Parameters
CELL=cell Cell designation This is a symbolic name of a defined cell. LISTTYPE=listtype Type of measurement frequency list. This parameter indicates in which mode the Mobile Station (MS) will measure on the frequencies in the list. ACTIVE Measurement frequency list to be used by active MSs IDLE Measurement frequency list to be used by idle MSs MBCCHNO=mbcchno Absolute Radio Frequency (RF) channel number for measurement on Broadcast Control Channel (BCCH) The number is the absolute RF channel number for the BCCH for cells to be measured on by a MS in the cell. Numeral 128 - 251 (GSM 800) Numeral 1 - 124 (GSM 900, P-band) Numeral 975 - 1023, 0 (GSM 900, G1-band) Numeral 512 - 885 (GSM 1800) Numeral 512 - 810 (GSM 1900) MRNIC Measurement results not interpreted correctly At updating of the measurement frequencies, measurement results are not interpreted correctly for a period of time.

2 Function
This command initiates or adds frequencies that MSs will measure on in the cell. If the type of measurement frequency list is not specified, then both idle and active lists are changed. The command is valid only for internal cells, that is cells belonging to the current Base Station Controller (BSC). If the parameter MRNIC is specified, or the cell state is halted, then the updating of the measurement frequencies is performed immediately. In this case the measurement results are not interpreted correctly for a period of time. EXECUTED will be printed. If the parameter MRNIC is not specified, the updating of the measurement frequencies is performed over a period of time and the measurement results are interpreted correctly. ORDERED will be printed and the result printout ADDITION OF CELL MEASUREMENT FREQUENCIES COMPLETED is received. If the global system type is MIXED, it is possible to add frequencies in the combination of GSM 800 band, GSM 900 band, and GSM 1800 or GSM 1900 band. The frequencies in G1 band can only be defined in a cell if the optional feature Extended GSM Frequency Band support is available in the system. The availability of the optional feature depends on commercial agreements.

file:///C|/Users/Diego/AppData/Local/Temp/ALEX_TMP/1000/alex0000.htm[12/8/2010 8:41:42 AM]

Libraries in: C:\Users\Diego\02_ALEX Library

Basically up to 32 measurement frequencies can be defined in a frequency list. If the global system type is MIXED, the following restrictions will apply according to the band in which the BCCH is defined and the combination of measurement frequency bands. The following restrictions apply to both IDLE and ACTIVE list types. If the list type is not specified, the restrictions are checked for both IDLE and ACTIVE lists.

Table 1

Table 1. GSM 800 Cell with BCCH in 800 band

Measurement Frequency Bands 800 (1) P G1 P + G1 (4) 1800/1900 (1)

1800/1900 + P (2)

1800/1900 + G1 (1)

1800/1900 + P + G1 (2)

Frequency Range (1) Range < 113 Range > 112 No limitation No limitation No limitation Range < 113 112 < Range < 257 Range > 256 Range < 257 256 < Range < 513 Range > 512 Range < 257 256 < Range < 513 Range > 512 Range < 257 256 < Range < 513 Range > 512

Max. No. Meas. Freq. 32/31 (5) 22 32/31 (5) 32/31 (5) 22 32/31 (5) 22 18 22 18 16 22 18 16 22 18 16

Table 2

Table 2. GSM 900 Cell with BCCH in P band or G1 band or undefined

Measurement Frequency Bands P G1 1800/1900 (1) 800 (1) 800 + 1800/1900 (1)

Frequency Range No limitation No limitation Range < 113 112 < Range < 257 Range > 256 Range < 113 Range > 112 Range < 513 Range > 512

Max. No. Meas. Freq. 32/31 (5) 32/31 (5) 32/31 (5) 22 18 32/31 (5) 22 18 16

Table 3

Table 3. GSM 1800/1900 Cell with BCCH in 1800/1900 band

Measurement Frequency Bands P G1 P + G1 (4) 1800/1900 800 (1) 800 + P (1) 800 + G1 (3) 800 + P + G1 (3) Note: Note:

Frequency Range No limitation No limitation No limitation No limitation Range < 113 Range > 112 Range < 113 Range > 112 Range < 257 Range > 256 Range < 257 Range > 256

Max. No. Meas. Freq. 32/31 (5) 32/31 (5) 22 32/31 (5) 32/31 (5) 22 32/31 (5) 22 22 18 22 18

1. The frequency range is defined as ( highest MBCCHNO - lowest MBCCHNO + 1 ) 2. The frequency range is defined as (1024 + highest MBCCHNO in P band) - lowest MBCCHNO in 1800/1900 band + 1 3. The frequency range is defined as (1024 + highest MBCCHNO in 800 band) -lowest MBCCHNO in G1 band + 1 4. The frequency range is defined as (1024 + highest MBCCHNO in P band) - lowest MBCCHNO in G1 band + 1

Note:

Note:

file:///C|/Users/Diego/AppData/Local/Temp/ALEX_TMP/1000/alex0000.htm[12/8/2010 8:41:42 AM]

Libraries in: C:\Users\Diego\02_ALEX Library

Note:

5. If the IDLE UTRAN measurement frequency list, specified in command RLUMC, contains any UTRAN Measurement Frequency Information (UMFI), then the maximum number of MBCCHNOs in the IDLE UTRAN measurement frequency list is 31. If the ACTIVE UTRAN measurement frequency list, specified in command RLUMC, contains any UMFI, then the maximum number of MBCCHNOs in the ACTIVE UTRAN measurement frequency list is 31.

The order remains after system restart.

3 Examples
3.1 Example 1
RLMFC:CELL=LIN1,MBCCHNO=9&11&107&108,LISTTYPE=IDLE; The command will add the following measurement frequencies to be used by an MS in idle mode in cell LIN1 in the BSC: 9, 11, 107, 108

3.2 Example 2
RLMFC:CELL=LIN2,MBCCHNO=15&17&512&520,MRNIC; The command will add the following measurement frequencies to be used by an MS in either idle or active mode in cell LIN2 in the BSC: 15, 17, 512, 520 The measurement results are not interpreted correctly for a period of time.

4 Printouts
4.1 Check Printout
Yes.

4.2 Procedure Printouts


EXECUTED ORDERED NOT ACCEPTED fault type Fault type:

FUNCTION BUSY The function is busy. FORMAT ERROR details The command or a parameter was incorrectly specified. UNREASONABLE VALUE details The parameter was specified with an unreasonable value.

FAULT CODE 3 CELL NOT DEFINED The cell is not defined. FAULT CODE 14 MBCCHNO ALREADY GIVEN details The measurement frequency has already been given. FAULT CODE 21 MAXIMUM NUMBER OF MBCCHNO EXCEEDED The maximum number of measurement frequencies is exceeded. FAULT CODE 38 COMMAND NOT VALID FOR EXTERNAL CELLS The command must not be used for external cells, that is cells belonging to another BSC. FAULT CODE 50 ACTIVE BA-LIST RECORDING IS ACTIVE It is not possible to change neither the active list nor the idle list when the function Active BA-List Recording is active for the cell.

file:///C|/Users/Diego/AppData/Local/Temp/ALEX_TMP/1000/alex0000.htm[12/8/2010 8:41:42 AM]

Libraries in: C:\Users\Diego\02_ALEX Library

FAULT CODE 171 PARAMETER VALUE NOT SUPPORTED BY THIS EXCHANGE details The possibility to define an MBCCHNO in G1 GSM band depends on commercial agreements.

4.3 Answer Printouts


This command has no answer printouts.

4.4 Result Printouts


ADDITION OF CELL MEASUREMENT FREQUENCIES COMPLETED

5 Logging
Yes.

6 Command Category Group


Recommended value 43 (H'2B)

7 Command Receiving Block


RCMFA

8 Glossary
BCCH BSC GSM MS RF UMFI UMTS UTRAN Broadcast Control Channel Base Station Controller Global System for Mobile Communication Mobile Station Radio Frequency UTRAN Measurement Frequency Information Universal Mobile Telecommunications System UMTS Terrestrial Radio Access Network

9 References
9.1 Command Descriptions
RLUMC Radio Control Cell, UTRAN Measurement Frequency Data, Change

9.2 Printout Descriptions


ADDITION OF CELL MEASUREMENT FREQUENCIES COMPLETED

file:///C|/Users/Diego/AppData/Local/Temp/ALEX_TMP/1000/alex0000.htm[12/8/2010 8:41:42 AM]

Libraries in: C:\Users\Diego\02_ALEX Library

file:///C|/Users/Diego/AppData/Local/Temp/ALEX_TMP/1000/alex0000.htm[12/8/2010 8:41:42 AM]