You are on page 1of 9

CPCB Zonal Office, Bangalore

VRV BOQ

BILL OF QUANTITIES (BOQ) FOR THE VRF SYSTEMS Sl.no.


PART A EQUIPMENT

Description Supply of new factory supplied air cooled Variable Refrigerant Flow System. Supply of variable Refrigerant Flow modular type airconditioning system complete with indoor & outdoor units with individual corded controller as per the following capaicties of the IDU and ODU.

Unit

Qty

Rate

Amount

1.1 2

Outdoor Units Modular type outdoor units equipped with highly efficient scroll compressors with all inverter type compressor(s) only, special acryl precoated heat exchanger, low noise condenser fan, pre coated fin type heat exchangers. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. All refnet piping system shall be imported. Refrigerant should be R410A. All structural frame work platforms required shall be of HVAC vendor as per site conditions. 30 HP Indoor Units for above mentioned outdoor unit Ceiling mounted four way air discharge cassette indoor units with conpact cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamicaly balanced and designed for silent operation, the filters shall be Plasma and synthetic washable media type arranged for convenient cleaning and replacement, built in drain pump, the drain pan shall be fabricated out of heavy sheet steel insulated with 6mm' expanded polythylene sheet. 1.5 TR 2.0 TR 3.0 TR Hi wall mounted units with plasma and synthetic washable filter. 0.75 TR 1.0 TR 1.5 TR 2.0 TR Wired Remote controls for all the Hi-wall and Cassette type units which shall be sleek and self diagnostic type. Simple Central Controller Unit capable of controlling all the Indoor and outdoor units Ref nut Joints/Branch Distributors for Indoor & Outdoor units 30 HP - 2 Nos. SUB TOTAL FOR EQUIPMENT 1 of 9

Nos

a b c

Nos Nos Nos

3 8 2

a b c d 3

Nos Nos Nos Nos Nos

4 4 10 4 35

Nos

5 a

Lot

KHANDEKAR ASSOCIATES

CPCB Zonal Office, Bangalore Sl.no.


PART B ANCILLARY

VRV BOQ Unit Qty Rate Amount

Description WORKS

I a II a b c

Installation, Testing and commissioning of units Installation, Testing and commissionig of Outdoor units including the transport and lifting and complete structural frame work plat forms as per site conditions. outdoor units 30 HP Indoor units Cassette Units 1.5 TR 2.0 TR 3.0 TR Hi wall units 0.75 TR 1.0 TR 1.5 TR 2.0 TR Refrigerant Piping Supply and installation of Refrigerant Copper piping insulated with Nitrile Rubber Tubular Insulation with cov ered with polyshield 54.1 mm with 19 mm thick insulation 41.3 mm with 19mm thick insulation 34.9 mm with 19 mm thick insulation 28.6 mm with 19mm thick insulation 25.4mm with 19 mm thick insulation 22.2 mm with 13 mm thick insulation 19.1 mm with 13 mm thick insulation 15.9 mm with 10 mm thick insulation 12.7mm with 10 mm thick insulation 9.5 mm with 8 mm thick insulation 6.4 mm with 8 mm thick insulation Drain Piping UPVC heavy class drain piping for SPLIT UNITS and Cassette type units for the following diameters of the pipes. The pipes shall be insulated with 6mm thick nitrile rubber. 19 mm 25 mm 32 mm Electrical Cabling Armoured copper cables from the isolator to the units at terrace. (Power Cable) ( the size of the cabel to selected by the vendor as per the manufacturer standard and to be approved by the consulanat. 30 HP - 2 Nos Control Cabling PVC insulated copper conductor control 2 of 9 cables

Nos

Nos Nos Nos

3 8 2

a b c d 2

Nos Nos Nos Nos

4 4 10 4

a b c d e f g h i j k 3

RM RM RM RM RM RM RM RM RM RM RM

RO RO 20 60 RO 30 15 175 140 160 125

Rmt Rmt Rmt

250 100 RO

Rmt

30 KHANDEKAR ASSOCIATES

CPCB Zonal Office, Bangalore Sl.no. Description b 2 C X 1.5 sqmm, as per relevant IS c 2 C X 1.0 sqmm as per relevant IS 5 All civil works pertaining to Air-conditioning like breaking, making, painting of walls, glass etc. as required as per site conditions. Note 1: Catalogues of all equipments shall be enclosed with Compressor rating charts. Note 2: Incoming Power supply near indoor unit will be provided by other agencies. Note 3: Taxes to be included in the price of equipments /accessories... SUB TOTAL FOR ANCILLARY WORKS TOTAL for VRF Systems Unit RMT RMT Qty 350 350 Rate

VRV BOQ Amount

Lot

3 of 9

KHANDEKAR ASSOCIATES

CPCB Zonal Office, Bangalore BILL OF QUANTITIES (BOQ) FOR MISCELLANEOUS & COLD ROOM Sl.no.
PART A

AHU COLD ROOM

Description EQUIPMENT FLOOR STANDING AIR COOLED SPLIT AIR CONDITIONERS supply of the Floor standing Air Conditioner Supply of the Floor standing Air Conditioning Equipments of the following capacity complete with the rotory compressor, condensor, evaporator complete with the all the controls . 2.0 TR 3.0 TR Installation testing and commissioning of Floor standing Units The necessary pedestals MS stand for supporting the condensers shall be included.5 Rm of refrigerant piping per circuit shall be included.Local isolators to be included for outdoor units. Nitrile rubber tubing shall be used for insulation. The price should also include cabling between indoor and outdoor. 2.0 TR 3.0 TR Soft drawn Copper refrigerant piping with necessary fittings of the following sizes. 1/2" 3/8" 1/4" Insulation for Copper refrigerant piping using nitrile rubber tubings for the following pipe sizes. 1/2" 3/8" 1/4" Drain piping using water quality blue HDPE pipe with GI fittings 40 mm dia 32 mm dia 25 mm dia COLD ROOM Supply, installation, testing and commissioning of the 1.25 TR Refrigeration Equipment complete with the rotory compressor, condensor, evaporator and copper refrigerant piping complete with the all the controls as per the approved shop drawings / specifications.

Unit

Qty

Rate

Amount

a b

Nos. Nos.

2 2

a b

Nos. Nos.

2 2

Rmt Rmt Rmt

50 50 QRO

Rmt Rmt Rmt

50 50 QRO

5 i ii iii II

Rmt Rmt Rmt

QRO QRO 25

4 of 9

KHANDEKAR ASSOCIATES

CPCB Zonal Office, Bangalore Sl.no. Description The scope of work also includes the setting up of the insulated sandwiched panels of self extinguishing quality EPS as the core, sandwiched between 2 layers of 0.5 mm thick pre-coated steel. the panels should be manufactured to a width of 1.18 M, for the entire cold room including the ceiling and the floor. The door of size 7ft X 3 ft with the automatic door closer which is again insulated shall be in the scope of AC contractor. DEHUMIDIFIER Supply, installation, testing and commissioning Desiccant Dehumidifier which shall be able to install above the false ceiling and of non toxic, non flammable with maximum moisture removal capacity to keep the specified room volume of 700 cu..ft, to maintain a condition of 40 5 % RH @ 72 5 F by a process air flow of 100 cfm as per specifications. All civil works pertaining to Air-conditioning like breaking, making, painting of walls, glass etc. as required as per site conditions. Note 1: Catalogues of all equipments shall be enclosed with Compressor rating charts. Note 2: Incoming Power supply near indoor unit will be provided by other agencies. Note 3: Taxes to be included in the price of equipments /accessories... SUB TOTAL FOR ANCILLARY WORKS TOTAL CONTRACT VALUE Unit Qty

AHU COLD ROOM Rate Amount

Lot

a III

Nos

QRO

IV

Lot

5 of 9

KHANDEKAR ASSOCIATES

CPCB Zonal office, Bangalore BILL OF QUANTITIES (BOQ) FOR EXHAUST SYSTEM Sl.no. Description PART A EQUIPMENT 1 Floor mounted Exhaust Blower Supply, installation testing & commissioning of Ceiling suspended Double skin Centrifugal DIDW Exhaust Blower complete with mounting arrangement & vibration isolators - for second floor lab area. a 4500 cfm with 75mm static Ceiling Mounted Duct in line Fresh Air Fan Supply, installation testing & commissioning of Ceiling suspended Fresh Air Blower . a 1000 cfm 2 a b Ceiling Mounted Duct in line Exhaust Fan 2500 cfm with 25mm static 300 cfm with 25mm static Floor mounted duct in line 250 cfm with 20mm static Axial flow fan complete with the filter section and the entire fan assembly housed in a double skin accoustically treated unit. 200 cfm with 20mm static Wall / Window mounted Exhaust fan 500cfm 250 cfm SUB TOTAL FOR EQUIPMENT PART B ANCILLARY WORKS 1 DUCTING WORKS Supply, installation, testing & commissioning of GSS Ducting with angle flanges & Hitec supports. The entire duct shall be fabricated with MS angle flanges. Slip 1A joints are not acceptable. a b c d 24 G 22 G 20 G 18 G Supply, installation, testing & commissioning of Aluminium factory fabricated eliptical ducts of 22 G sheets with angle flanges & Hitec supports, painted with zinc chromate primer and 2 coats of approved colour with fittings as follows. 24 G 22 G 20 G 18 G SQM SQM SQM SQM 100 60 RO RO Unit Qty

Exhaust Systems BOQ

Rate

Amount

Nos

Nos

Nos Nos Nos Nos

1 7 1 1

c d 3 a b

Nos Nos

2 1

a b c d

SQM SQM SQM SQM

RO 75 RO RO

6 of 9

KHANDEKAR ASSOCIATES

CPCB Zonal office, Bangalore Sl.no. Description 2 ACCOUSTIC INSULATION AHU Room accoustic insulation of walls and ceiling with 48kg/m resin bonded fibre glass wool with 50mm thickness covered with GI frame (grid 600 x 600mm) and covered with 22G GI perforated sheet. FLEXIBLE CONNECTION Flexible connection (non canvas type) SUPPLY AIR DIFFUSERS (SAD) Supply & installation of Aluminium Powder coated supply air diffuser with OBD outer size 375 x 375 and neck size 225 x 225 GRILLS Supply & installation of aluminium powder coated Fresh Air & Exhaust air Grills VOLUME CONTROL DAMPERS (VCD) Supply & installation of GI Volume Control Dampers with matching flanges COLLAR DAMPER Aluminium Opoosed Blade Collar dampers FLEXIBLE HOOD CONNECTION ARRANGEMENT The elephant trunk type flexible pipe connection suitable of connecting to the exhaust duct as per the tender drawing specification to be approved by client/consultant made of PVC/Aluminium with the flexible duct complete with canopy type inlet terminal The Robo arm type flexible pipe suitable of connecting to the central exhaust duct as per the tender drawing specification. FIXED FUME HOOD CONNECTIONS The fixed fume hood connections to be made to the specific equipments. The connection shall be of G.I./ aluminium directly with the exhaust duct. The control shall be provided with the damper. ELECTRICAL CABLING Electrical Work: (PVC armoured al./cu cables) 4 C x 16 Sq.mm (cu) 4 C x 10 Sq.mm (cu) 4 C x 6 Sq.mm (cu) 3 C x 4 Sq.mm (cu) 3 C x 2.5 Sq.mm (cu) 10 C x 1.5 Sq.mm (cu) 4 C x 1.5 Sq.mm (cu.) 8 SWG GI wire earthing End termination 7 of 9 12 FILTERS Unit Qty

Exhaust Systems BOQ Rate Amount

SQM

75

b 4

Nos

Nos

20

SQM

SQM

SQM

Nos.

Nos.

ii 10

Nos.

11 a b c d e f g h i

RM RM RM RM RM RM RM RM Lot

RO RO 20 80 20 RO RO 120 1 KHANDEKAR ASSOCIATES

CPCB Zonal office, Bangalore Sl.no. i Description The filters to be arranged in the plenum of the exhaust HEPA Filter HEPA Filter of following size arranged with 0.3 Micron filteration and efficency upto 99.97% suitable for 4500 CFM and 250 CFM fans. The size and the no. of filters to be as per the manufacturer's standards. 300 mm thick Activated Carbon Filters Activated Carbon Filters with high density carbon filled, fibrous adsorption medis that adsorbs and controls airborne gases, VOCs( volatile organic compounds) iii 13 100 mm thick 10 Micron pre Filters (Microvee) 150 mm thick Civil works All civil works pertaining to Air-conditioning like breaking, making, painting of walls, glass etc. as required as per site conditions. Note 1: Catalogues of all equipments shall be enclosed with Compressor rating charts. Note 2: Incoming Power supply near indoor unit will be provided by other agencies. Note 3: Taxes to be included in the price of equipments /accessories... SUB TOTAL FOR ANCILLARY WORKS TOTAL CONTRACT VALUE FOR EXHAUST WORKS Nos. Lot 2 1 Unit Qty

Exhaust Systems BOQ Rate Amount

Lot

ii

Lot

8 of 9

KHANDEKAR ASSOCIATES

CPCB Zonal Office, Bangalore

Summary

PROPOSED CPCB ZONAL OFFICER AREA SUMMARY SHEET - ACMV WORKS SL NO DESCRIPTION TOTAL VALUE

TOTAL FOR VRV SYSTEM

TOTAL FOR MISCELLANEOUS

TOTAL FOR EXHAUST WORK

GRAND TOTAL FOR THE ENTIRE AC WORKS

9 of 9

KHANDEKAR ASSOCIATES

You might also like