Professional Documents
Culture Documents
ATV58
Bonne performance fonctions simples
ATV62
ATV08 ATV08
DC injection
Jog
CSA CE UL
single-phase200/240 V (0.37 to 2.2 kW) three-phase 200/230 V (3 to 7.5 kW) three-phase 380/500 V (0.75 to 15 kW)
Pumps
Special machines
/ Agitators
Remote
"PowerSuite" software
link
Confidence in performance
Speed range 1:50 1.7 Tn at 3 Hz without adjustment Sensorless flux vector control Auto-tuning Braking transistor in-built Output Frequency range up to 400
Hz
1,7 Tn Tn
1 3 10
Schneider Electric General Presentation
20
30
40
50Hz
10
11
13
VERSIONS
- ATV58 P (Plate)
for installation on the machine frame (according to thermal weight) for installation with separate heatsink porjected behind the panel to reduce panel size
ATV 58 Compact up to 5,5 kW & ATV 58 Energy from 7,5 to 75 Kw For installation near the motor where motor cable is too long
12
1-
28
power ratings divided into 7 IP21 sizes IP41 on the upper part according to standard EN
50178 (IP65 kit for keypad remote location on the enclosure door.)
Integrated
compliance EN 61800-3 and EN 55011 level A (irrespective of switching frequency) from 18,5 kW to 75 kW (380-500 V), version without integrated filters also available
13
High torque : 170% overtorque Examples : Hoisting , crushers, conveyor... Standard torque : overrating, 120 % overtorque Examples : Pump, fan ...
14
2-
Technology
Power
rating < 15 kW
RFI filter coil and capacitors
Ferrite
Capacitors
Mini SKIIP
15
2
Technology
"MiniSKIIP" is a new IGBT module technology (3ed generation) developed by SEMIKRON and is used for ATV58 size 1,2 and 3.
Contact with the card is done by placing pressure (spring blades) on the printed circuit as opposed to dip-soldering. The card is pressed between the module and a part which maintains the pressure.
A reliable, compact and economical solution due to optimized current distribution and use of materials with a high thermal cycle capacity. Mounting costs are lower as 20 to 40 soldering points are eliminated. Mounting on the printed circuit uses only one or two standard screws. The component can be fully dismantled and recycled. From a manufacturing point of view, it has the necessary flexibility.
16
2- Technology Power rating > 15 KW Line Chokes integrated Half controlled rectifier (diodes & thyristors)
Replaces the diode bridge, the load resistor & the contactor.
Braking
bar
17
2- Technology
Power rating > 15 KW Bus bar : strengthen all the connections inside the controller
(wiring is robust and fixed)
Line
chokes
Low frequency harmonics reduced Reduced voltage distorsion Controller immunity to disturbances Equipment size reduced
Capacitors DC
bus
18
4-
Keypad
19
4-1-1
The
Keypad
(VW3-A58101)
keypad is removable and can be delivered with the controller or separately (to order a controller without a terminal: ATV58PU09M2Z)
This
keypad can be connected or disconnected with voltage . If the drive is controlled with the terminal and if deconnected : SLF fault will occur. keypad can be used to control, adjust and configure the ATV58
This 4
Configuration can
Plain
IP
20
4-1-4
Extension cards
Tacho-generator
feedback card
2 logic inputs Differentiel analog input (0 +10V or 0 -10V) 1 logic output 1 analog output + 10V / - 10V supply
Pulse
2 logic inputs 1 logic output 1 analog output AA ; BB (encoder 24 VDC) or A only (inductive sensor)
21
4-1-6
host software for X tel (Telemecanique) and Orphee (April) Plus : Tlmcanique and Modicon PLCs S: 24 V DC external power supply for connection on the main ring (VW3A58304E). Drivecom Profile 21 (message handling included) : Drivecom Profile 21 (Maximum transmission speed :1,5 Mbit / s) Delivered with bus configuration floppy disc
Modbus
Interbus
Profibus DP
Unitelway / AS
-i
22
6-1
Flux
Performance - Torque
vector control without sensor in steady state:
Torque
With factory settings: Tn for a 1:50 frequency range With optimized settings: Tn for a 1:100 frequency range
23
6-3
For an IEC 4-pole motor operating over the catalog speed range (1:100)
Speed accuracy in open loop Without slip compensation: motor slip With slip compensation: +/- 1 % of the nominal speed for a torque variation of 0.2 Tn to Tn with factory settings Speed accuracy in closed loop With TG analog feedback: +/- 0,1 % of the nominal speed With digital feedback via sensor: the optionnal board measures the number of pulses for 5 ms ; accuracy depends on the sensor (0,02% for 1024 points)
24
7-2
Controller protection
output phases output phases and earth
Drive
overtemperature Overload with continuous or transient current It. Use of controller above operating temperature Breakdown of controller fan (Thermistor on heatsink) Automatic reduction to 2 KHz or 4 KHz if overtemperature rise at 8-1216KHz (according to controller rating)
25
comfort
The
Altivar
dedicated
38,
functions...
and so simple :
Air conditioning and heating. Air treatments and regulation of water circuits Ventilation. Pumping.
Immediate start-up Simplified setup. Easy integration in installations. Suitable solution for the building enviournment..
27
kW
Enhanced
Summary
28
Concentrated
functions...
With Altivar
38,
PI regulator, Automatic restart, Catch on the fly, Smoke extraction function, Pump switching (card in option), Three jump frequencies, etc.
29
Concentrated
functions......
for air conditioning and heating
Adjustment of flow rates on the basis of actual need for better energy management: use of built-in PI regulator. Suppression of mechanical resonance with jump frequencies. Enhanced comfort with reduced noise pollution caused by fan operation: flux vector control dedicated to pump and fan applications.
Grande Arche
(La Defense / France)
Transamerica Pyramide
(San Francisco / USA)
Canary Warf
(London / Great Britain)...
30
Concentrated
functions...
for pumping applications
management of a set of pumps, maintaining constant pressure and spreading wear and tear between the pumps with the Altivar 38 switching function.
Autonomous Simplified
start-up and diagnostics with Altivar 38. of installation faults:if a pump is faulty, it is no longer taken into account during operation.
Management
31
Simplified setup
Simple, user-friendly dialog tools
Just
Built-in display
with parameters protected by padlocking.
enough
No
time wasting, a limited number of adjustments needed for a quick and efficient setup.
Terminal, PC or Pocket PC with the Power Suite* software workshopfor use on site or in the office, etc
*
Software which is common to the Altivar range of variable speed drives. Available in 5 languages : french, english, deutsch, spanish and italian.
32
follow...
Graphic
Facilitated adjustments
PowerSuite - Atelier logiciel - ATV38-3 (connect)
ATV382
Safety
with
33
Easy integration
in installations
Compact,
Low-cost,
the protection kit for direct wall-mounting offers IP21 degree of protection.
34
Easy integration
in installations
Open
used
35
Easy integration
in installations
Transparent Building TM
With the Ethernet card and a simple Web browser, Transparent BuildingTM lets you manage your buildings from any location, at any time with total efficiency.
Ethernet TCP/IP
36
Suitable solutions
for the building environment
Mastering
From
electrical distribution
transformer to motor control, a complete offer for protection, distribution, supervision, control and monitoring of your equipment.
To
plant
37
ALTIVAR 68
to go even further...
and compressors
simple hoisting
39
ATV-68 : an open loop range for : pumps and fans special machines (centrifuges, extruders, grinders) simple handling applications ATV-68F : a high-performance range with closed loop feedback for : hoisting and handling
40
3 motor reactive energy-saving levels (flux) Integration of ATV68 in Eco 8 (pump and fan energy savings) Process PID With or without correction of internal set point (weight roll) Auto/manual operation, devalidation of ID gains Braking by motor loss Without braking module
41
of logic inputs/outputs to supervision of external events external faults, earth fault, overpressure contact
Line
Assignment
contactor control
42
43
LEDs
MENU
45
46
Altistart 48,
Pumps
48
A complete range having international approvals & certifications. Performancee with exclusive TCS concept Protection at all levels
applications Pumps
Fans
and so simple:
Easy integration :
in In
49
A complete range
International standards and approvals : IEC 60947-4-2. CE Marking. EMC : classes A and B. UL / CSA DNV (marine, off-shore) C-TICK / GHOST / CCIB / NOM.
For 50 and 60 Hz
Wide tolerance range for generators.
From 17 to 1200 A
415 V: 7.5 to 630 kW. 690 V: 15 to 1200 kW.
Altistart 48, ready-to-use : Factory set, the Altistart 48 is operational immediately. Wire it, connect and start...
50
With motor torque control, Altistart 48 provides perfect control of the machine starting and stopping.
The Altistart 48 TCS system is the only system enabling to: Maintain gradual acceleration up to nominal speed, even incase of high starting torque. Improve the lifetime of the belts and machinery.
Difficult starting causing motor temperature rise. Sudden end of accelaration causing mechanical stress Difficult adjustment compromise.
51
Protection
at all levels
motor
Thermal protection : by calculation of the I2t in accordance with IEC 60947-4-2.
machine
Underload protection : running dry, broken transmission, Overload protection : clogging, incident... with adjustable thresholds and times. Stalled rotor. Control of the direction of rotation. Excessive acceleration time.
Preheating function preventing condensation. Detection of Some protections can be handled like alarms phase failure. without interrupting the machine operation.
52
& Flexible Selectable trip classes meet the requirements for a wide range of applications
53
Simplified wiring with through connections on all models. Altistart 48 controls : a starter by- pass contactor at the end of starting with all protective functions maintained (thermal, underload, overload, etc) > Elimination of heat dissipations in enclosure. a line contactor. Fans activated and deactivated according to the heatsink temperature. Avoids unnecessary noise and circulation of dust, Increases the lifecycle of the fans.
Motor
54
Firing circuits
Ventilation autotransformer
Microcontroller
console visualisation
55
of electrical values (current, power, etc), load conditions and operating time.
Display
Maintenance of
configurable inputs/outputs (4 logic inputs, 2 logic outputs, 3 relay outputs and and 1 analog output).
56
Pocket PC Just follow the Power Suite software User-friendly software for configuring the various parameters.
Schneider Electric General Presentation
57
Integrated
Modbus. :
Communication modules
For remote access to control, monitoring and Ethernet TCP/IP for setting up Transparent adjustment Factory : open control systems platform based on Internet functions technology.
58
Twin Line
AC synchronous servo and stepping motor drive in one line of devices
3
AC
Line Controller
with integrated power electronics, equipped with micro-modules for application-specific configurations
59
The following options are possible l Gearbox l Holding brake l Multiturn measuring system AC synchronous servomotors (servomotors) l Encoder (stepping motors) high performance continuous torque 0,34 to 50 Nm
60
Power electronics for 3 phase stepping motors TLD 011and TLD 012
Power electronics for AC synchronous servomotors for standard and high performance motor line TLD132,TLD 134, TLD136, TLD 138
61