VES - 2110 DESIGN OF STEEL BRIDGES

TABLE OF CONTENTS PAGE 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 SCOPE REFERENCES GENERAL DESIGN CRITERIA STEEL STRUCTURE WOOD DECK RAILING RETAINING WALL RAILING COATING 3 3 4 4 4 5 5 5 5

File: F:\WPDATA\NEWVES\2002\VES2110

Page 2 of 5

VES-2110 Rev. 4, 11/02

1.0

SCOPE This specification defines the minimum requirements for steel structure and wooden deck bridge. Bridges shall be 5.0 m wide. In order to accommodate small boat traffic which may traverse creeks over which bridges are constructed, it is necessary to design the structure accordingly. This shall be done by ensuring that there is a clear passage way of a minimum 5.0 m in width at the center of the creek which provides a minimum clearance of 2.0 m at high water level between the water and the underside of the bridge structure. This specification is general in nature. It is required that Contractor generate detailed specifications based on these documents plus drawings as required for construction.

2.0

REFERENCES The latest edition of the following codes, standards and specifications, except as modified herein, shall form a part of this specification. Peraturan Konstruksi Kayu Indonesia - PKKI. AISC, American Institute of Steel Construct, Specification for the Design, Fabrication of Structural Steel for Buildings. Specification for Design of Cold-Formed Steel Structural Members (USA). ASTM, American Society for Testing of Materials, A36, Specification for Structural Steel. A301, Specification for Hot Formed Welded and Seamless Carbon Steel Structural Tubing. AWS, American Welding Society, Structural Welding Code, D1-1. AASHTO, The American Association of State Highway and Transportation Officials. VES-2010, Site Preparation, Grading, Fencing, Production Area. VES-3010, General Structural Steel Construction. VES-3020, General Piling Work. VES-5140, Surface Preparation, Painting and Galvanizing. If a conflict between standards, codes, and specifications which form part of this Specification arises, Contractor shall immediately notify Company in writing. Generally, the following order of priority shall govern in the event of a conflict: i) ii) iii) Scope of Work, Drawings, Contract for the project. VICO Engineering Standards. Standards, Codes and Specifications of any other technical organization

File: F:\WPDATA\NEWVES\2002\VES2110

Page 3 of 5

VES-2110 Rev. 4, 11/02

Throughout this Specification, the following definitions are applicable: Company : VICO Indonesia, a Division of Virginia Indonesia Company LLC. The company awarded the contract to carry out the work to which this specification applies. The applicable design drawings as listed in the Scope of Work. Refers to all national, regional, local, and municipal organizations with jurisdiction over matters related to structural steel work.

Contractor

Drawings

Government Authorities

Contractor shall comply to all the various requirements of the Government Authorities (BP Migas, Ditjen MIGAS and others) with respect to structural steel construction. Company will not accept ignorance of these requirements as cause for delay or as basis for a claim against Company.

3.0

GENERAL DESIGN CRITERIA All drawings and calculations shall be submitted to Company for review, comments, and approval. The bridge shall be designed in accordance with AASHTO, Standard specifications for Highway Bridge. The design load for the bridge shall be the standard classification for highway loading of HS-15, Group A AASHTO standard specifications of highway bridges. Piling shall be installed in accordance with VES-3020, Piling Works. The pile bearing capacity calculation shall be based on the engineering formula:

P=
E S P = = = per blow ft. lbs. Set in inch Allowable bearing capacity in lbs.

2E S +0.1

4.0

STEEL STRUCTURE The bridge structure and foundation shall be steel pipe piles. Pile driving records shall be furnished as specified.

5.0

STEEL DECK FRAME The bridge deck frame shall be structural steel.

File: F:\WPDATA\NEWVES\2002\VES2110

Page 4 of 5

VES-2110 Rev. 4, 11/02

6.0

WOOD DECK The bridge deck shall be top quality ulin sawn timber available on the local market. All timber shall be straight and free of knot holes. The deck shall consist of solid layer of ulin timber. Curb boards and running boards shall be placed on this layer. The running boards shall be 1.0 m wide and strapped and bolted in place every 1500 mm.

7.0

RETAINING WALL A retaining wall shall be installed at the edges of the stream. The wall shall extend past the edge of the bridge on all sides as shown on drawing. The wall shall be constructed of ulin (5 x 20) cm sawn timber and held in place by ulin (15 x 15) cap piles. Bracing post and diagonal framing should be ulin (10 x 10) cm. Back fill the retaining wall sand as per VES-2010.

8.0

RAILING The railing shall be 4" galvanized pipe columns and 2" galvanized pipe railing. The top railing shall be painted with zebra cross paint - yellow/black.

9.0

COATING All external surfaces of the jetty frame and structure are to be coated, including deck retaining angles or plates. All surface protection work shall be performed in accordance with VES-5140.

File: F:\WPDATA\NEWVES\2002\VES2110

Page 5 of 5

VES-2110 Rev. 4, 11/02