You are on page 1of 4

ProductSpecification

03305(Rev.C)

ProActITB
IntegratedActuatorandThrottleBody forlargebores(85to180mm)

No linkage or couplings Cost effective and highly efficient Low maintenance Requires no hydraulics, pneumatics, or governor gear train Long lasting, easy to install throttle option Can be configured as an integrated speed controller or a positioner

Description
The ProAct Integrated Throttle Bodies (ProAct ITBs) are butterfly valves electrically-actuated by ProAct Analog and ProAct Digital Plus actuators to control flow output. With bore sizes ranging from 85 mm to 180 mm, these ProAct ITBs are designed for use with engines in the 12 MW range. The ProAct actuators are electromagnetic, 75 degree-of-travel devices, and therefore alleviate the problems associated with linkages on gas engines (such as setup, non-linearity, and wear). This direct combination of throttle and actuator results in excellent stability and transient characteristics, and requires no hydraulics, pneumatics, or governor gear train. Therefore, you end up with an efficient, long lasting, and easily-installed throttle option.

Application
The ProAct ITB integrated actuator and throttle body is designed to throttle air or air/fuel for gaseous engines. This system is designed for direct replacement of traditional throttle valves, and requires no linkage between valve and actuator. The three sizes are designed to cover a wide range of engines and should be selected using the sizing procedure described inside this specification.

Woodward 03305 p.2 d

Det termining gtheProp perValve eSize


The p proper size va alve can be determined us d sing the equat tion below. Th required C (flow coeffi he Cv icient) should be calcu ulated for both the minimum and maxim h m mum flows exp pected on the application. T This design a allows for a no ominal trave of 75 degree of rotation. el es Using the graph a table belo select the closest valve that has a C equal to or greater than the calculate g and ow, e Cv ed maximum flow val at approximately 80% o lue opening (60 d degrees) to ensure reason nable flow margin. Also, check that the p particular valves minimum Cv listed belo is less tha the minimu calculated Cv for good low idle perfo ow an um d ormance. For further assista ance, consult the Woodward engineerin department ng t.
where: Cv = Q= Sg = T1 = P1 = P2 = Flo Coefficient ow Ma Flow (PPH [pounds/hour]) [1 pound = 0.4 kg] ass ) 45 Spe ecific Gravity o Gas (use 1.0 for air) of 0 Upstream Gas Te emperature (F [F = 1.8 * C +32] F) C Inle Pressure (ps [1 psi = 6.8 kPa = 0.06895 bar] et sia) 895 Downstream Pres ssure (psia)

Q 0.00 976 ( T 46 0) P1 Sg Cv P1 Sg g P1 P2

NOTE EP2 must be greater than 0.528 * P1 or flow becomes c e 0 choked. If P2 is less than 0.52 * P1, then us P2= 0.528 * P1. 28 se

Spe ecification ns
Available Size es Operating Tem O mperature Rang ge: Digital Plu us Analo og Storage Tem mperature Rang ge cation Test Spe ec Vibration Qualific Shock Qualific cation Test Spe ec Weig ght Nominal Diamet ter Working Pressure Maximum W 85, 95, 105, 120, 135 160, 180 mm 5, m 40 to +85 C (40 to +185 F) o 40 to +74 C (40 to +165 F) o 55 to +125 C (67 t +257 F) to Woodw ward RV2 (0.1 G G/Hz Random 102000 Hz, 12.8 Grms 3 hours per axis) m, , 40 G, 1 ms sawtooth pulse 11 h See tab under moun ble nting section of manual 135 mm (5.3 inches), 120 mm (4.7 inches), or 105 mm (4.1 inche m 5 es) 60 psig (414 kPa/4.1 bar) g

Regulatory Com mpliance


Note Refer to the ProAct Digital Plus manual (2 26112) or ProA Analog man Act nual (26147) fo actuator com or mpliance. Europ pean Complian for CE Marking: nce Pressure Equip pment Directive 97/23/EC of e Pressure Certified to P Equipment 29 May 1997 on the approx 7 ximation of the laws of the e Member States concerning pressure equi g ipment, Catego II ory Directive: Other European Compliance: r Comp pliance with the following Euro e opean Directive does not qua alify this produc for applicatio of the CE Ma ct on arking: Machinery ent EC Compliance as a compone with 98/37/E COUNCIL Directive: DIRECTIVE of 23 July 199 on the appro 98 oximation of the laws of the M e Member States relating to machinery.

Woodward 03305 p.3

ProAct ITB 85/95 with ProAct Digital Plus Model II (also available with ProAct Analog) (Do not use for construction)

Woodward 03305 p.4 d

Pro oAct ITB 120 with ProAc Digital Plus Model II (al available w ProAct A 0 ct s lso with Analog) (Do not use for constructi ion)

For more informa ation contact:


PO Box 1519, Fort Collin CO, USA 805 ns 522-1519 East Drake Road, Fort Collins CO 80525 O 1000 E Tel.: +1 (9 970) 482-5811 Fax: +1 (970) 498-3058 www.wood dward.com Distributor & Service rs Woodw ward has an inte ernational networ of distributors and service facilities. rk For yo nearest repre our esentative, call th Fort Collins plant or see the he Worldw wide Directory on our website.
ocument is distribut for informationa purposes only. It is not to be constr ted al rued as This do creating or becoming part of any Woodward contractual or war t rranty obligation un nless ten expressly stated in a writt sales contract.

Wo oodward 2008, All Rights Rese erved

2011/4 4/Colorado

You might also like