DE-MYSTIFYING ELECTRICAL SYSTEMS ON MERIDEN TRIUMPHS Version 3.0 By Pete Kinlyside TriumphRat.

net OzBloke, Melbourne, Australia


This paper attempts to explain the intricacies of Meriden Triumph electrical systems. The idea for the paper was born from my own challenges with these systems, and from the many electrical questions being raised by other owners on the TriumphRat.net Classics web forum. Ive tried to explain how things work in two formats; the simple non-technical format, and the deeper technical format. Its not meant to replace workshop manuals, but to supplement them. Hopefully it will help those who want to maintain and fault-find these sometimes frustrating but always amazing older bikes.

Contents
1. 2. 3.

Page

Common Terms .................................................................................................. 2 Diagnostic Table................................................................................................. 3 Ignition Systems ................................................................................................. 7 3.1 Simple Science ............................................................................................ 7 3.2 Extra-Technical Explanation........................................................................ 8 3.3 Faults in the ignition system ........................................................................ 9 3.4 Points ........................................................................................................ 10 3.5 End-to-end testing. .................................................................................... 12 3.6 Boyer Electronic Ignition Systems ............................................................. 13 3.7 Fault-finding a Boyer setup ....................................................................... 14 4. Charging system ............................................................................................... 16 4.1 Rectifier .................................................................................................... 16 4.2 Fault finding bridge rectifiers .................................................................... 18 4.3 Zener Diode............................................................................................... 19 4.4 Testing a Zener Diode ............................................................................... 20 4.5 Alternator ................................................................................................... 21 4.6 Testing the Alternator stator ...................................................................... 21 4.7 Battery ....................................................................................................... 22 4.8 End-to-end Charging system testing .......................................................... 23 5. Indicators.......................................................................................................... 23 6. Lighting System ............................................................................................... 24 6.1 Faults in the lighting system ...................................................................... 25 7. Horn ................................................................................................................. 26 7.1 Fault finding a horn ................................................................................... 26 8. A Few Tips ....................................................................................................... 27

Version 3.0

Nov 2009

Page 1

1. Common Terms
First, some terms you might see, read or hear when working on your bike, and which I use in this paper Term Earth Voltage Current Resistance Meaning The common return path for electrical current, usually the frame of the bike, plus the engine. Aka: frame, chassis or ground. The measure of electricity force or pressure, measured in Volts The measure of electricity flow, stated in Amps The measure of resistance of a certain component to current flow, measured in Ohms ( ), or Kilohms (1000 Ohms or K), or Megohms ( 1 million ohms or M ) aka. Short circuit. A path for current that bypasses vital components usually associated with a fault, resulting in high current flow, burnt wires, blown fuse, bad smells, and sometimes fire. A broken path, which does not allow current to flow, Usually associated with broken wires, poor connectors, blown fuse, or faulty components. Aka HT. The high voltage output from the coil. The connection from the secondary winding of the ignition coil to the spark plug the spark plug lead. An electrical part that performs a function. Examples are coil, switch, battery, rectifier, diode, lamp, Radio Frequency Interference. Electronic noise radiating from electrical components due to magnetic fields generated by current flowing through a conductor. Can be heard as clicks on an AM radio. RFI can be closely associated with EMI electromagnetic interference, where voltage spikes are introduced into circuits from radiated energy, causing failures or errors in computerised equipment eg computer-based ignition systems. A physical connection between two components, usually with a centre conductor of copper, and an outer sheath of plastic or cotton, and a metal connector at each end. Aka cable, lead. Wires gathered together in a larger common sheath (or bound with tape) are known as the loom. An analogue or digital meter used as test equipment, capable of several working modes, such as Resistance, Voltage, Current, Diode check.

Short

Open Circuit

High-tension

Component RFI

Wire

Multimeter

Version 3.0

Nov 2009

Page 2

2. Diagnostic Table
The table is used to diagnose basic problems with the electrics on Meriden Triumphs. Positive earth is assumed. Symptoms may be noticed en mass or individually. Suggested actions for a particular problem do not align with specific symptoms, but should be taken in the order shown until the problem is resolved. Problem No Power Symptoms Oil light does not come on when ignition switch turned to On. Engine will not start. No lights No brake light (with ign on and brake lever pulled or brake pedal pressed) Suggested Actions 1. Check fuse if in doubt, replace with a new 20A fuse. Clean the terminals inside the fuse holder. 2. Check battery voltage should be =>12.3V. If lower than 11.5V, re-charge or replace battery. 3. Check battery connections are clean and tight. 4. Check connection to frame from battery is clean and tight. 5. Check connections to ignition switch. 1. Check wiring to Ign switch 2. Check lighting switch 3. Check globes 4. Check / clean/ tighten connections to lights, including earth/frame connections 5. Check/clean handlebar switches 1. Check power to Negative of each coil with Ign switch On. Should be -12V or greater. If not, check wiring from Ign switch, via kill switch (if fitted) to coils. 2. Check Positive terminal of each coil. Should read -12V with points for that cylinder Refer to Section

Power, but no lights

Oil light comes on with Ign switch turned On, but no lights (headlight, tail light, pilot light)

Power, but no spark (Points ignition)

Engine will not start. No spark at either plug (with plugs out and resting on head fin, with HT lead still connected).

Version 3.0

Nov 2009

Page 3

3.

4.

5. Power, but no spark (Boyer) Engine will not start. No spark at either plug (with plugs out and resting on head fin, with HT lead still connected). 1.

2.

3.

4.

5. 6. Power, but no spark on one cylinder only (Points ignition) Engine runs rough, with no power. One cylinder cold/warm, with other one hot. 1.

2.

3. 4. 5. 6. 7. 1.

Power, but no spark on one cylinder only (Electronic ignition)

Engine runs rough, with no power. One cylinder cold/warm, with

2.

open, and 0V with points closed. If constant 12V, check wiring to points for an open circuit eg dirty or broken connector, broken wire. If constant 0V, check wiring for a short to frame, or points wire contacting earth inside timing well. Check coils primary windings for continuity. Check power to EI system. If not -12V, check wiring from Ign switch via kill switch (if fitted) to EI unit. Check power to negative terminal of 1st coil (coils are wired in series). Should be 12V after 1 kick, and last for up to 5 seconds unless another kick occurs. If constant -12V, check connection to EI unit, or EI unit needs to be checked/replaced. If 0V, check pickup wiring. Check the wire connecting the Positive terminal of 1st coil to the Negative terminal of 2nd coil Check earth connection from Positive terminal of 2nd coil. Check both coils for primary winding continuity Check spark plug (swap with other cylinder). If fault moves cylinders, replace plug Check HT plug lead (swap with other cylinder). If fault moves cylinders, replace HT lead. Check coil has power to negative terminal. Check points opening/closing Check wiring from points to coil positive terminal. Check connection to condenser. Check coil windings Check spark plug (swap with other cylinder). If fault moves cylinders, replace plug Check HT plug lead (swap with other cylinder). If fault moves

Version 3.0

Nov 2009

Page 4

other one hot. Charging system not working Engine runs poorly or stops when battery gets low. Battery needs to be charged after every ride. Ammeter (if fitted) showing negative (discharge) >3 Amps. Battery voltage with engine running at 3000 RPM is 12.5 V or lower, and does not rise or drop with engine revs Cant run for extended periods with headlight on, else engine runs poorly or stalls. Battery voltage with engine running at 3000 RPM is between 12.5V and 13.5V. Ammeter (if fitted) shows slight discharge at 3000RPM with headlight on. Battery gets hot Battery boils off liquid, and needs constant topping up. Battery voltage at high revs goes over 15V Blowing light globes regularly. Ammeter shows charge of greater than 4 amps for more than 10-15

cylinders, replace HT lead. 3. Check coil windings 1. Check connections from alternator stator to rectifier. 2. Check connections from Rectifier to battery, via fuse 3. Check earth connection to rectifier. 4. Check battery earth/frame connection 5. Check alternator stator continuity.

Charging system weak

1. Check for poor connection between alternator and rectifier, looking for corroded or broken metal parts in connectors, and frayed wires. 2. Check, clean and tighten blade connectors on rectifier, and check wiring to battery (via fuse, and ammeter if fitted). 3. Check rectifier 4. Check alternator stator for continuity.

Charging system on steroids

1. Check connections to Zener diode. 2. Check earth connection on Zener diode. 3. Check Zener diode for proper operation. 4. If using after-market regulator, get it tested, or replace it.

Version 3.0

Nov 2009

Page 5

Indicators not lighting at all

mins. When indicator switch set to L or R, indicators do not come on at all

Indicators on constant (not flashing)

When indicator switch set to L or R, indicators come on solid but do not flash

Indicators slow flash

Indicators fast flash

When indicator switch set to L or R, indicators come on but flash slowly When indicator switch set to L or R, indicators come on but flash too quickly Not working clicking sound when horn button pressed

1. Check indicator globes 2. Check earth connections to stalks 3. Check wiring from handlebar switch to globe holders. 4. Check wiring from Ign switch to flasher can, and from flasher can to handlebar switch. 5. Check/replace flasher can 1. Check battery voltage. 2. Check for correct wattage indicator globes (21W) 3. If this only happens at idle revs, check charging system (weak) 4. Check/replace flasher can 1. Check for correct wattage indicator globes (21W). 2. Check charging system 1. Check for blown globe, or broken connection to one globe 2. Check for incorrect wattage globes 3. Check/replace flasher can 1. Use adjustment screw on rear of horn to obtain correct tone. Screw clockwise. 2. Check for poor connections and frayed wires 1. Check connections from horn switch to horn, and from horn to earth. Note that earlier bikes switch the earth via the handlebar switch, while later models switched the power. 2. Check adjustment screw screw until sound is heard when pressing button. 3. Check horn internally for poor contact points and misadjustment.

Horn

Horn

Not working no sound

Version 3.0

Nov 2009

Page 6

3. Ignition Systems
This section explains the inner working of Meriden Triumph ignition systems, from the basics such as the theory behind the system, to the more advanced areas like Boyer ignition systems. Ignitions systems are built from a combination of components. For most older bikes (except magneto ignition systems), these are: The battery The fuse The ignition switch The engine kill switch The points (aka breaker points, contact points) The condenser(s) (aka capacitor) The coil(s) The spark plug(s) The wires between the various components, in particular the plug leads.

For the sake of simplicity, take it for granted that Im explaining things using a single cylinder at this point. Not much difference with a twin or triple cylinder engine, where most components are duplicated, except when you get into the electronic systems such as Boyer or RITA.

3.1

Simple Science

One terminal of the battery is connected to earth. Most modern bikes are negative ground, while the older Meriden Triumphs are positive ground. Positive earth (or positive ground) means that the positive terminal of the battery is directly wired to the frame and engine of the bike to provide the return path for the electrical current, and the negative terminal of the battery is the active terminal. The other terminal of the battery is wired to the fuse, then from the other side of the fuse to the ignition switch, and from there to the kill switch (if fitted), and from the kill switch to one side of the coil (in the Meriden case, the negative terminal of the coil). With the ignition switch off, no current flows to the coil, and no spark can be produced. With the ignition switch and the kill switch both in the on position, 12 volts is applied to one side of the coil. The coil is basically a 1:100 transformer. It has a primary winding, being the two screw/blade terminals on top for positive and negative 12 volts connections. The other half is called the secondary or high tension winding. One end of the secondary winding connects to the negative terminal, while the other end connects to the insulated cup connector on the top, into which the plug lead is connected. The set of points, operated by the camshaft, acts as an on/off switch for the positive side of the coil to earth. When the points are closed, current flows from the battery, through the fuse, through ignition and kill switches, through the coil, through the points contacts, to the engine casing, and finally back to the positive side of the battery via wires and/or frame. At this stage, the condenser, which is wired across the points, is not charged, as the points short it out. Diagram 1 illustrates the components and the current path.

Version 3.0

Nov 2009

Page 7

Ign Sw Fuse

Kill Sw

Battery

Spark Plug

Condenser

Current Flow

Coil

DIAGRAM 1

Points

This current flow quickly creates an electromagnet inside the coil. While the points are closed, this magnetic field remains stable. At a point in the rotation of the camshaft, a lobe on the points cam causes the points to open. Current is no longer flowing through the coil, and the magnetic field quickly collapses. This collapsing magnetic field causes a voltage to be induced or generated in the secondary winding. The condenser comes into play now, as its no longer being shorted by the points. It has a dual function to help pump up the primary voltage, and to drastically reduce arcing across the points. The primary voltage goes up to around 300-400 volts, and the secondary voltage leaps to 20-30 thousand volts. This secondary voltage is sufficient to jump the gap between the spark plug centre electrode and the side (ground) electrode, and current flows from the coil secondary, through the spark plug, through the engine to the frame, through the condenser, to the negative terminal of the coil. When the voltage being developed by the collapsing field inside the coil is no longer sufficient to jump the gap, the spark stops.

3.2

Extra-Technical Explanation

As the points open, the magnetic field around the primary winding of the coil begins to collapse. This induces a voltage across the secondary and primary windings. The condenser initially acts as a short until it starts to charge. This stops arcing across the points contacts, as the potential difference between the points grows comparatively gradually. As the voltage builds across both the secondary and primary, no current is yet flowing through the secondary, as the current path is not yet established across the spark plug gap. Around 400 volts can be developed across the primary winding as the condenser becomes fully charged. Depending on the spark plug gap, and the state of the fuel vapour /air mix between the plug electrodes, at a certain voltage, the vapour will ionise, and allow current to pass. This commences the spark. As the current flows through the secondary winding, the condenser discharges through the primary, thereby inducing more voltage across the secondary, which elongates the spark time. This loop effect, or ringing, continues in a decreasing cycle until the condenser no longer holds sufficient charge to induce enough voltage in the secondary to maintain the ionisation of the plug gap, which is when the spark stops. Without the

Version 3.0

Nov 2009

Page 8

condenser, the spark will be of very short duration, and quite weak. The points will also arc on each opening, causing pitting of the contact surfaces and eventual breakdown.

3.3 Faults in the ignition system


Note: Voltages in the ignition circuit can be harmful, and painful! Do not touch connectors or components with the engine running. Resistance testing of ignition components must be done with the fuse out and ignition switch off, and preferably with the component completely removed from the electrical circuit.

Testing of the condenser can be done by using a multimeter on the highest resistance (20M - 20 Mohms) range. Take one of the bike electrical connections off the condenser, and connect the probes across the component, watching the meter display as you connect the probes. The meter should indicate a low initial resistance, with a rapid increase in resistance as the condenser charges over a period of a few seconds. The meter should, after no more than 5 seconds, indicate infinite resistance. If it shows some steady high resistance (eg 10Mohms), or slowly decreases after initially going high, the condenser needs to be replaced. Make sure your fingers arent touching the metal portion of the probes when you do this test, as it will give false readings. The ignition condensers can be tested in either polarity, with the same results. If reversing polarity immediately after a test, the initial meter reading may be false due to the charge on the condenser from the meter. Coils can go faulty in a number of ways. The primary can go open circuit due to vibration or heat (continuous current for extended periods burnout). The secondary can go open, or can short turns (a current path between layers of the winding, resulting in greatly reduced output), or a short to the outer case. Testing of the coil is a 4 step process. First take all connections off the coil, including the high-tension lead (plug lead). Using a multimeter on low resistance range (200), check the resistance between the two low tension (primary winding 12 Volt) connectors. 6 volt coils should read around 2 to 2.5 ohms. 12 Volt coils should read between 4 and 5.5 ohms. If higher, it could be faulty or a higher voltage (eg 24v) coil. If lower, shorted turns are the most likely culprit replace. Next, check the secondary winding by a resistance (meter on 20K range) check between the negative 12V terminal and the high-tension output (the brass connector inside the tower where the plug lead goes). This should be around 5 to 6 K. The last check is between either the negative terminal, or the high tension terminal, and the metal casing, with meter on highest range. Should be infinite resistance from either point. Again, make sure your fingers arent touching the probes, as a false reading will result. If not infinite resistance, the coil has a short to the case, and should be replaced. Spark plug leads can be tested by checking resistance from end to end. Meter on 20K range for Suppressor leads, or 200 for copper core leads. For copper core high-tension leads, resistance should less than 1 between the metal connectors at the ends. Radio frequency interference suppression leads can be identified by either reading the writing on the lead (it will say its suppressor lead or similar), or by taking the rubber boot off one end and looking where the lead enters the metal connector. Suppressor lead centre conductor looks like a number of strands of tiny fishing line coloured dark grey or black. Suppressor leads will measure around 5 K for the approx 600 mm length. Any higher,

Version 3.0

Nov 2009

Page 9

they are possible faulty or the wrong type, and they start to limit the high-tension current to the point where the spark strength is degraded. Similarly, spark plugs can be tested with a meter. Good idea to give the firing end of the plug a scrub with a brass or wire brush to remove any carbon or burnt oil deposits that could give a false reading. Suppressor plugs have an in-built resistor to limit the current of the hightension system, thereby limiting the RF interference caused by the ignition system. Plugs without in-built resistor should read less than 1 between the top cap (where the lead plugs on) and the centre electrode at the firing end. The suppressor plugs will read around 4 to 5 K between top cap and the centre electrode. Both types should read infinite resistance between top cap or centre electrode and the metal casing. If in any doubt, replace the plugs theyre fairly cheap. Total suppressor resistance, from the coil end of the plug lead to the centre electrode at the firing end of the spark plug, should not exceed 5 K . Any more than this and the spark may be weakened to the point where misfires or no spark could occur under normal operating conditions. Copper core plugs leads will give the more powerful spark, but may cause interference on nearby TVs, radios, computer equipment, etc. If you use a computerised ignition system or other electronic equipment on your bike, use suppression leads or resistance plugs to a maximum of 5 K resistance. Its not a good idea to use both resistance plugs and suppressor leads together. One or the other will be fine for suppressing RFI.

3.4

Points

There are two types of points plates used on older Triumphs, both shown below. The first is the older style, where the condensers are mounted on the points plate itself, and the centre conductor of each condenser is used to provide a connection point for both the points spring, and the wire to the coil. Note the small plastic tab between the condenser and the spring this stops the spring metal, or the connector on the wire to the coil, shorting to the case of the condenser (earth). The plastic tab also extends to stop wires or connectors shorting to the side of the points well in the timing case.

Version 3.0

Nov 2009

Page 10

The newer style of points plate is shown below.

Note that the condensers associated with the newer style of points plate are mounted on the bracket holding the coils, not on the points plate. There is a small fibre washer between the outer casing of the condenser and the coils plate, stopping the outer casing from shorting to earth. The centre positive pole/stud of the condenser is used to secure the condenser to the plate, and the wire to the coil is connected to a blade connector soldered onto the outer casing of the condenser. The most important thing to note about this newer type of points plate is the insulators between the base plate, the stud holding the points spring, and the point springs itself. See Diagram 2 below. If the connector on the wire from the coils touches the stud or the nut, it will short out the points no spark on that side and the coil will get really hot with the ignition on. The wire connector must contact the points spring, but not the stud or nut.

This type of connector slides in here

Stud Nut Steel lock washer Insulating plastic washer with protrusion

Points spring (cut-away to show detail of insulator) Insulating fibre washer Base plate

DIAGRAM 2

Points can be checked by doing a resistance check between a) the point where the wire connects to the points and b) engine metal (ground/earth). Note that the other end of the points wire must be disconnected from the coil to do this test. 0 for points closed, and

Version 3.0

Nov 2009

Page 11

infinite resistance for points open. Note that the condenser may still be in circuit (if its mounted on the points plate), so points open resistance reading may take a few seconds to reach infinite.

3.5

End-to-end testing.

If all components check out OK, a fault in the ignition system is most likely to be a bad connection or broken wire. The following tests are done with the fuse in, and live 12 volts applied to the ignition system. For safety, take the spark plugs out and rest them on the head with leads still connected. This way, theres no way the engine can start, and you can see if a spark occurs at the plug. Keep your hands and other body parts away from the electrical components and connectors. They get hurt if they get hit with ignition voltages. Make sure you have no fuel or gas vapours in the vicinity, or fuel leaks. Have a fire extinguisher handy just in case. Meter on 20V range. One lead on battery earth (positive terminal on older British bikes) or on a good bare metal part of engine or frame. Ignition switch on, kill switch to run. Place the other meter probe on the power side of the coil primary (negative terminal on older bikes). Meter should read between 12.5 and 13.8 volts. If lower (eg 11 V), check state of battery. If no voltage reading, check the battery earth connection, then the fuse, then the ignition switch, then the kill switch, and the cables and connectors between all these components. You can use the meter probe to test for -12v along this route. Once you have -12V at the power side of the coil primary, rotate the engine until the points are open. Measure voltage at the other primary connector on the coil (+ on older bikes) should be -12V. If not, could be an open circuit coil, or a shorted condenser, or a short circuit to earth in the points cabling or points themselves. Most likely cause is the wire connection to the actual points being frayed or misaligned, or a missing insulator on the stud holding the points spring the wire must connect to the points spring, but be insulated from the mounting stud (see Diagram 2 on the previous page). Follow through by turning the ignition off, and checking resistance of the coil primary, and the resistance between earth and the points wire. Once you get -12V on both sides of the coil primary with points open, rotate the engine until the points close. You should now see 0 Volts on the points side of the coil primary (+ on older bikes). If not (ie still seeing greater than 0.2 volts), then there is either a broken wire or connector (open circuit) between the coil and the points, or the points are not closing properly. Points not closing will usually be caused by mechanical misalignment, or by an obstruction between the points contacts such as oil, dirt, corrosion, pitting/carbon, etc. If all checks out OK, with fuse in, ignition on, kill switch to run, use the kickstarter to turn the engine over. Check for spark at the spark plug (still resting on the head). If no spark at all, check the plug lead and spark plugs as described previously. A further check is the test for voltage at the plug end of the high-tension lead. Meter on 20V range, ignition on, points open, one meter probe on battery earth/frame. DO NOT kickstart, or close/open the points, or turn the ignition switch off, with meter connected to the plug lead, you will damage your meter. Disconnect the plug lead from the spark plug, and connect the other meter probe to the metal end of the lead. You should see around 10 to 12

Version 3.0

Nov 2009

Page 12

V on the meter. If not, lead is faulty, or secondary winding of coil is open circuit. Check components as described previously, and replace as required.

3.6

Boyer Electronic Ignition Systems

Electronic ignition systems available for motorcycles usually just replace the points, with some added electronics to provide for spark advance. They still require coils to generate the high-tension voltage for spark. Diagram 3 shows a typical Boyer setup, using 2 coils.

Fuse

Ign Sw

Kill Sw

White

Battery

Boyer
Red

Black

Spark Plug
Black

Black/White

Black/Yellow

Current Flow

Pickup Plate Coil

DIAGRAM 3
Coil

The Boyer control box has 5 connections. 1. 2. 3. 4. 5. The -12 volt power input line - White The -12 volt coil power output line - Black The +12 volt line Red One pickup sensor line Black/ yellow The other pickup sensor line. Black/white

Boyer control boxes need an absolute minimum of 10 volts to operate. If your battery is not well charged, and unable to supply a minimum of 10 volts under load (ie with ignition on), the unit will not operate. Power is applied to the control unit once the ignition switch is turned on, and the kill switch is in run. Power will not be applied to the coils until the first pulse is received from the pickup sensor unit, which is mounted where the points used to go and using the points wires to connect the pickup sensor unit to the control box. If pulses stop being sent from the pickup sensor, the power to the coils will be cut off approximately 3-5 seconds later. This is to stop coils being overheated and burnt out, and batteries being flattened, by continuously feeding power to the coils when it is not required. The lowest RPM that the Boyer will operate effectively is 200 RPM.

Version 3.0

Nov 2009

Page 13

Note that the coils are wired in series. That means the current path goes from the Boyer control box, through one coil, then through the other coil, and then to earth. Wiring coils in parallel will cause damage to the control box due to excessive current. The control box will limit the coil(s) primary winding voltage to 400V, and with two coils wired in series, this equates to 200 volts per coil. Depending on the coils used, this limiting may result in limited output voltage to the spark plugs. Converting to 2 x 6V coils gets around this possible problem something to think about if youre getting weak spark with a Boyer and 2 x 12V coils. Some people prefer a single 12v coil with dual high-tension outputs. Boyers fire both cylinders at once, at both the top of the compression stroke (when it should happen), and at the top of the exhaust stroke (when its not required, but doesnt hurt). This makes the design simpler, and also assures matched ignition timing between twin cylinders. The pickup sensor is simply two coils wired in series, and mounted 180 degrees apart, with their centre metal cores protruding. Magnets are similarly set onto a rotor fitted to the camshaft. As the rotor rotates, the magnets sweep close by the protruding metal cores, which induces a small voltage in the coils. This voltage pulse is fed to the control box via two wires, and is used to trigger the momentary disconnection of the negative power line from the ignition coils (virtually the same as opening the points), creating spark. When initially set up, the pickup sensor is timed at full ignition advance. When the engine is running at idle, the spark is electronically retarded by approximately 10 degrees. As the engine speed increases, less retardation is applied (more advance). Maximum advance (or more precisely zero retardation) is reached around 5,000 RPM. Condensers are not required in a Boyer setup. Note that if the pickup sensor cable are wired in reverse (crossed over), the pulse received will be the wrong polarity, and the control unit will actually sense the trigger pulse when the magnets are leaving the pickups coils, rather than as they approach. This has the effect of significantly retarding the spark (by around 50 degrees), and the engine will be virtually impossible to start. You will see spark, and everything will look good, but the timing will be way off. Make sure you get the polarities right from the sensor to the control box for the black/yellow and black/white wires.

3.7

Fault-finding a Boyer setup

Note that the fault-finding methods described here are for a positive earth bike, with two coils. Boyer control boxes need an absolute minimum of 10 volts to operate. If the battery is not well charged, and not able to supply at least 11.0 volts under load (ie. with ignition on), the unit may not operate properly. Make sure you have a good battery in place before doing any other fault finding. Check the 12v power side by meter on 20V range, connecting one probe to battery earth. Connect the other probe to the primary winding (12V) connector on the first coil that has the black power wire from the Boyer. Take the spark plugs out and rest them on the head with leads still connected. With ignition and kill switches on, rotate the engine with the kickstarter. After 1 or 2 revolutions of the engine, you should see 12v on the meter. This will return to zero volts after 5 seconds or so, so watch carefully. Now check the pickup sensor. Take both the black/yellow and black/white wires out of their connections to the Boyer control box. With meter on 200 range, measure the resistance between these two wires going to the sensor plate. You should read 132 . If significantly

Version 3.0

Nov 2009

Page 14

lower than 132 , one of the sensor coils may be shorted, or the printed circuit board that the coils are mounted on may have a short between tracks. If significantly more than 132 , or infinite resistance, there is probably a faulty connector between the control box and the pickup sensor. Check the resistance of each wire from end-to-end individually, and check the resistance of the sensor at the connector on the senor plate itself. The last check you need to make is the wiring of the coils. With meter on 200 , and ignition off, check the resistance from the -12V primary connector on the first coil, to the +12V connector on the other coil that means across both coil primaries. For 2 x 12V coils connected in series, you should read no more than 10 . For 1 x double ended 12V coil, or for 2 x 6V coils, you should read no more than 5 . If more, its most likely the wire joining the two coils together, but could also be a faulty primary winding on either coil. If the power connections, coils connections, and the sensor checks above check out OK, and youre sure of the good state of the battery, the fault will probably be with the control box. If its just been fitted, and not yet worked at all, check that the right connections are being made to the control box, as per the Boyer instructions. With ignition on, if you disconnect the two wires at the sensor plate (black/yellow and black/white) and tap them together rapidly, you should see spark at the plugs As mentioned previously, you should have no more than 5 K total resistance on each plug lead / resistor spark plug combination.

Version 3.0

Nov 2009

Page 15

4. Charging system
The charging system on the Meriden Triumphs is quite simple. An alternator, a rectifier, and a zener diode, along with the battery of course. The alternator has two parts. A rotor, which is basically a strong magnetised cylinder mounted on the outer end of the crankshaft, and a stator, which is a ring of coils on a toroidal (donut-shaped) iron core, mounted around the rotor. As the magnetised rotor is spun by the engine, its magnetic field cuts through the winding of the coils, generating a voltage in the coil. Because of the rotation, and the north/south poles of the magnet, the voltage alternates between positive and negative. When an electrical load is applied and current flows, it is called alternating current, or AC (also why its called an alternator).

4.1

Rectifier

To be useful in a direct current (DC) environment such as bike electrics, this alternating current must be changed (rectified) to direct current. This is the job of the rectifier. The rectifier is basically 4 high current diodes wired in a Bridge Rectifier pattern, which converts the positive/negative AC voltage from the alternator to all-positive or all-negative voltage. Extra-Technical Information Diagram 4 shows a typical bridge rectifier setup and corresponding waveforms. Please note that I use the electron flow theory to explain operation.

AC input from alternator

DC output

+15 0

0 -15

-15

DIAGRAM 4

Diodes only pass current in one direction think of it as the current being able to go up the slope of a diode, but not up the cliff. Looking at Diagram 4 above, when the AC voltage is fed to the input, in one half of the AC cycle current is passed by the top left and bottom right diodes, while the other two diodes are reverse biased and pass no current. In the other half cycle, the top right and bottom left diodes are the ones forward biased and passing current, while the other two are blocking current flow. This results in a Direct Current (DC) output made up of both the positive and negative halves of the AC input. Note that the older style rectifiers use the mounting bolt as the earth connection for the positive DC output. The picture below shows a typical bridge rectifier.

Version 3.0

Nov 2009

Page 16

~
The centre mounting bolt also provides the earth path. The positive output wire (ground/earth) goes on the centre bolt at the top, the two wires from the alternator go on the outer two of the three terminals grouped together, and the negative (live) wire to the fuse goes on the centre connector of the three. An alternative and cost-effective rectifier can be made using a common solid-state 25 Amp bridge rectifier as shown in the picture below, available from your local electronics shop for around $5.

Bolt the rectifier through the centre mounting hole to an L bracket, and mount the L bracket where the old rectifier was. Connections are the same, except you might have to also wire the positive (if system is positive earth) DC output to earth the L bracket.

Version 3.0

Nov 2009

Page 17

4.2

Fault finding bridge rectifiers

To test a bridge rectifier, the easiest way is to use a multimeter with a diode checker. This will be indicated by a certain switch position on the meter, or a combination of switches, showing the diode symbol. In this mode, the meter will show the voltage drop across a forward biased diode, therefore the position of the probes is important when checking diodes. To eradicate the possibility of either the alternator or the rest of the bike electrics affecting your testing, take the fuse out, and remove all the wires connecting to the rectifier. Be careful to note which wires go where you dont want to put them back in the wrong place or youll end up cooking some wiring. You have 8 checks to do forward and reverse on each diode in the set of 4. Use a multimeter on Diode check mode. Using Diagram 4 and the picture above as an reference, the first test would be putting the red probe on the negative output connector, and the black probe on either AC input connector. This will forward bias one of the left hand diodes, and you should read between .400 and .700 on the meter. Test the other left hand diode by moving the black probe to the other AC input connector. Reading should be very similar. Now reverse the two probes so the black is on the negative output connector, and the red probe is on either AC input connector. You should read infinite 1 blank on an LCD screen multimeter. Swap the red probe to the other AC input connector to check the other diode. Now test the right hand diodes by placing the black probe on the positive DC output connector (may be the centre bolt/earth on the older rectifiers), and the red on either AC input connector. Again, you should see .400 to .700 on the meter. Check the other diode by swapping the red probe to the other AC input connector. Now check the reverse bias by placing the red probe on the positive DC output, and the black probe on either AC input. You should see 1 blank on the meter.

Version 3.0

Nov 2009

Page 18

If at any stage during this testing, you see something like .003 or any similar low reading, it means the diode being tested is faulty. The same diode will probably measure the same in the reverse test, as its burnt out and imitating a piece of charcoal. If this is the case, its time to replace the whole rectifier.

4.3

Zener Diode

The symbol for a Zener diode is shown here. The Zener diode is basically a rudimentary voltage regulator, and is used to stop the alternator/rectifier voltage getting high enough to cause damage to the battery, lighting globes, coils, etc. The zener is special in the sense that it acts as a normal diode in the forward biased state (as explained in the Rectifier section current can flow up the slope but not up the cliff), but in the reversed biased state it will only block current until a certain pre-set limit is reached, and then it will conduct. This limit on 12 volt bikes is set at 15.0V. Zeners used as voltage regulators are wired in reverse-bias mode, and have high current and high power dissipation characteristics. Zeners will have either a finned heatsink, or be mounted on metal in an area of high air flow. Extra-technical information
Rectifier Rest of bike electrical load

Alternator

Zener

Battery

DIAGRAM 5

As alternator rotor speed increases, the magnetic lines of force cutting the windings of the stator increase in frequency. This not only increases the frequency of the AC output, but also the output voltage (amplitude). To protect electrical components, such as the battery from overcharging, and the light globes from blowing, the voltage must be controlled. As can be seen in Diagram 5 above (positive earth system), the AC output of the alternator is applied to the rectifier, which converts the AC to DC. This DC is then applied to the battery and the rest of the electrical system of the bike. The Zener is wired in reverse bias across the main power feed out of the rectifier. When the voltage at the output of the rectifier is less than 15 volts, the Zener is inactive, and has no affect on the rest of the electrical system. If the DC voltage on the anode (the cliff side) of the zener reaches the preset trigger voltage (15.0V) the Zener diode immediately goes into the avalanche condition, and provides a very low resistance path to earth almost a dead short circuit. Current flows through the Zener to earth. This has the effect of rapidly

Version 3.0

Nov 2009

Page 19

reducing the voltage coming out of the rectifier. As the voltage goes below 15 volts, the Zener goes back to passive state. Thus, the voltage coming out of the rectifier is limited to a maximum of 15 volts. This is commonly known as a crowbar regulator.

4.4 Testing a Zener Diode


The simplest test you can do on a Zener diode is to check it with a multimeter in diode test mode. It will act as a normal diode with the test voltage available through the multimeter. It should show 0.400 to 0.600 on the meter when forward biased, and 1 blank in reverse bias. For Zeners meant for positive earth systems, the base stud or heatsink will be the cathode (the pointy end of the triangle symbol), and the insulated blade connector will be the anode (the flat end of the triangle the cliff face). The wire from the battery/rectifier should be disconnected. Its OK to leave the Zener mounted, as long as you can find a bare metal earth point to put your probe on. Multimeter in diode test mode. For positive earth systems: Red probe on Zener blade, black on earth - .4 to .6 reading. Red on earth, black on blade 1 blank reading. For negative earth systems: Red on earth, black on Zener connector - .4 to.6 volts, Red on connector, black on earth 1 Blank reading. If the Zener is faulty, it will usually show up as a short circuit (low readings in both directions), and other problems with bike electrics will be quite evident constantly blowing fuses will be the main symptom. To test the reverse turn-on voltage of the Zener, use the following test circuit. Please note this is for Positive earth systems that is, Zeners with the cathode being the base mounting stud or heatsink. See diagram 6. Wire two standard 9 volt batteries in series as shown positive of one to the negative of the other. These are the standard batteries that go into toys, smoke detectors, multimeters, etc. In this test, its likely you will drain a fair bit of power out of them, so if you have to go and buy some, get the cheapest you can find.

18.50

DIAGRAM 6

Version 3.0

Nov 2009

Page 20

Once the batteries are wired together, use your multimeter on 20V DC range to make sure the combined voltage is above 15 Volts. Using a piece of wire, connect the stud or heatsink of the Zener to the positive battery point, and also wire to the red probe of the multimeter. Using another piece of wire, connect the negative battery terminal to the black meter probe. With meter on 20V DC range, you should see around 18-19 volts. Now touch the black probe (with wire still attached) to the blade connector on the zener. You should see the voltage drop down to 15 volts straight away. Dont leave it there very long 2 or 3 seconds should be heaps. The internal resistance of the batteries will limit the current, but the wires may still get warm or hot. If it goes below 15 volts (eg 1 or 2), you either have the diode forward biased (reverse the connections on the zener) or its faulty (perform the previous simple multimeter diode test). If this is the case, the wires will get hot really quickly, and the batteries may also get very hot if the probe is left on the Zener too long. This is why Ive suggested to just touch the probe on, and not wire it directly to the batteries easier and quicker to remove. If the voltage doesnt come down from 18 to 15 volts, the Zener could be open circuit (check your test connections, and do the simple diode test).

4.5

Alternator

Two basic types of alternator may be fitted to your bike; A single phase alternator, or a 3 phase alternator. Its pretty simple to tell which you have. Take a look at the wires and connectors coming out of the lead coming from the alternator. If you have two wires coming from the alternator, you have a single phase system. If you have 3 wires coming from the alternator, you have a 3 phase system. The 3 phase systems require a special 6-diode rectifier pack, and puts out a slightly higher current than the single phase system. The two basic parameters affecting alternator performance are the strength of the rotor magnet, and the speed of rotation of the rotor. The stronger the magnet, the greater the voltage developed across the stator windings, and therefore the greater the current capability. Maximum output current for a standard single phase alternator in new condition is approximately 9 amps. Magnets will lose some of their magnetism over time, because of mechanical shock and heat, thus reducing the output capability. The windings of the stator do not usually degrade in terms of performance, but can be affected by knocks during maintenance, or shorted turns due to insulation breakdown over an extended time. Output can also be reduced by frayed connections, where not all of the conductors in a wire are connected, and thus current-carrying capability is reduced.

4.6 Testing the Alternator stator


There are two fairly simple tests for the alternator stator, both done with a multimeter. Disconnect the cables coming out of the alternator, where they connect into the loom. Note which wires goes where before you pull them apart.

Version 3.0

Nov 2009

Page 21

Now with the multimeter on the lowest resistance range (200 ), test the continuity between the two wires coming from the alternator you should see around 1 or less. If more, you have a faulty wire or connector in the lead coming from the alternator, or a faulty stator (rare but possible). Now check the insulation from the stator to earth. Multimeter on highest resistance range (eg 20M ), and measure between one of the alternator wires and earth, should read infinite (1 then blank on the meter). Do not have your fingers on any probe metal parts, as this will give a false reading. If not infinite resistance, the stator could have a short to earth via the metal core, or the cable could be broken and touching the engine casing. Check the state of the connectors and the wires between all components, especially between alternator stator and rectifier. Frayed wires at the connectors limit the current capability of the wire, as all the wires dont make good contact. This can make the charging system operate below its full capacity.

4.7

Battery

The standard battery for the older triumphs is of the lead/acid variety, with a rating of 12 volts and 8-9 amp/hours. Some owners prefer to replace the lead/acid type with Absorbed Glass Mat (AGM) maintenance free type. They still contain acid, but have no drainage tube, are less susceptible to the affects of vibration, and have the same charging characteristics as the standard lead/acid batteries. They are smaller in size for the same amp/hour capacity, so fitting may present some issues (eg. Battery movement in the battery carrier cradle). Gel Cell batteries are not really suitable for these bikes, as significant modification to the charging system is required to limit the charge current to the battery. Fitting a Gel Cell to a bike with a standard charging system will significantly shorten the life of the Gel Cell. There are several tests that can be done on the battery, such as specific gravity of the electrolyte (liquid) with a hydrometer, fluid level, standing voltage, etc. but by far the most effective test that can be simply achieved is the voltage under load test. To do this test, first connect the multimeter on 20V range directly across the battery, and read the voltage with ignition off and all lights off. A fully charged battery will read pretty close to 12.8V. A 50% charged battery will read 12.2V with no load, and a discharged battery will read 11.9V with no load. Make sure the battery is fully charged before doing the load test. Motorcycle batteries should be charged at a rate of no more than 1 amp. High charge-rate car battery chargers are not suitable for motorcycle batteries, as their charge rate can be as high as 10-12 amps this level of charge will boil the motorcycle battery. Now turn the headlight on low beam. This will draw approximately 4 amps out of the battery. The battery voltage will drop to about 12.2 volts as soon as you turn the headlight on. Keep an eye on the voltage reading for a full 3 minutes. If it falls below 10 Volts, your battery is faulty, and needs to be replaced. If the voltage drops to 11 volts, the battery is weak, and you need to consider refurbishment or replacement. A good battery will read around 11.9 to 12.2 volts after 3 minutes. Switch the headlight off, and after two minutes check the reading again. That battery voltage should have crept back up to around 12.6 to 12.7 volts. If so, your battery is in good condition.

Version 3.0

Nov 2009

Page 22

4.8 End-to-end Charging system testing


If you are satisfied that all the charging system components are in good condition, you then need to check the overall system operation. The two basic checks to do for end-to-end testing the charging system are: Check the battery voltage with the engine running around 2000 rpm should read around 13.7 to 14.2 volts. If down at 12 volts, you have a problem with one or more of the charging system components, or cabling/connections between them. In a shaded area, locate the bike near a wall or similar, so the headlight will shine on the wall and you can readily see the light pattern. With engine running at idle, turn the headlight on high beam. Engine revs may drop a little (good, because the alternator is loading the engine). Rev the engine to 2000 rpm, and the headlight should get slightly brighter when the revs are up. This indicates that the alternator and rectifier are working. Lower the revs and the light should go slightly dimmer. If the light does not go brighter with revs above idle, perform the previous test for battery voltage at revs.

5. Indicators
The wiring for indicators is basically as illustrated in Diagram 7. Note that the return current path is via the ground/earth mounting of the indicator arms. Some after-market indicators do not make good earth contact at the mounting points, and may require star lock washers, or special extra wiring, to ensure a good earth. The indicator system is made up of four basic components; the indicator switch, the flasher unit (aka flasher can), the indicator lights themselves, and the indicator warning lamp.
Warning lamp

Indicator Switch (handlebar) Left Hand Side

Flasher Can

Right Hand Side

Fuse Ign Sw

Battery

DIAGRAM 7

Version 3.0

Nov 2009

Page 23

a) rest DIAGRAM 8

b) activated

The flasher unit, or flasher can, consists of two metal strips, one being plain metal with a contact at the end, and the other being two strips of dissimilar metals bonded together, again with a contact at the end. The bi-metal strip is surrounded by a heating element. When current passes through the heating element, through the contacts and along the plain strip (Diagram 8a), the bimetal strip is heated and bends (due to the different rates of expansion of the two dissimilar metals) (Diagram 8b). This breaks the contacts apart, current stops flowing, the heater elements no longer heats, and the bi-metal strip returns to its original position (a). The contacts make, current flows, heater heats, bi-metal strip bends, contacts break (b), and the cycle continues until current is stopped externally (switched off). This simple heat-based on/off switching method also allows you to see when an indicator main (front or rear) globe is blown by the quicker flash rate with a lower load. With one globe open circuit, there will only be half the current flowing. The heater heats the bi-metal strip to half the extent, the bi-metal strip bends to the point of just opening the contacts, and the bi-metal strip takes less time to straighten up again after the current is broken by the contacts opening. Similarly, if your battery voltage is low, the heater takes a long time to heat the bi-metal strip, and the indicator lamps will stay on longer, and will have a shorter off time. The indicator warning lamp (in the headlamp nacelle) works on the principle of a high resistance vs low resistance voltage divider. When 12V is applied to one side of the indicator system, and the lights on that side are on, 12V is also applied to one side of the warning lamp. The other side of the warning lamp is connected to earth via the filaments in the other side indicators. With its low wattage and therefore higher resistance, the main voltage is dropped across the warning lamp. A small amount of current actually flows though the other side filaments, but no enough to make them glow.

6. Lighting System
The lighting system is again fairly simple. The battery and charging system in combination are the source of current for the lighting system, and earth returns via the frame are common, although the main lamps have their own earth wire.

Version 3.0

Nov 2009

Page 24

The lighting switch will normally have 3 positions Off, Parking Lamps (aka Safety Lighting), and Main. The headlight beam also has a control switch mounted on the handlebar, switching between low and high beam. There are two possible ways to have the lighting power routed. One is straight from the battery via the fuse, and the other is to have the lights only available when the ignition switch is on. Both have pros and cons, and its really up to the individual owner as to which way works best for them.

6.1

Faults in the lighting system

The majority of faults in the lighting system are either globes blowing (filament going open circuit), or bad connections. Globes blowing will usually be caused by: poor quality globes being affected by vibration excessive vibration through worn or brittle mountings excessive voltage (open circuit or disconnected Zener) filament age if they built them to last forever, youd never buy any more Bad connections can be caused by: vibration connectors coming apart Cable movement broken conductors inside the insulation due to constant bending Corrosion due to age, or connections being exposed to the weather or corrosive elements (eg battery acid, fuel vapour, cleaning agents, etc) Poor earth connections due to attachment to frame with paintwork. The fault finding routine for the lighting system is as follows: If all lights dont work: 1. Check fuse and battery are in good condition. Check the fuse with a multimeter on low resistance range. Even though it might look OK, it may be broken near an end under the cap. 2. Fault is likely to be the lighting switch or a bad connection to or from it. If lights are wired only to come on with the ignition switch on, check the ignition switch as well. If its an individual light (not all of them) thats not working: 3. Check the globe. Either testing it in another known-good socket, or testing it with the multimeter on resistance range. Sometimes you can see the filament flopping around inside the glass, or grey/black stains on the inside of the glass, signifying the filament is blown. White stains on the inside of the globe signify that air has gotten inside the globe, and the filament has blown and burnt the oxygen. 4. If the globe is not the problem, check the earth connection for the socket. With the fuse out, check for continuity between the earth side of the socket and battery earth. Multimeter on low resistance range (200 ). If less than 1 or 2 ohms, move to next step. If more than 1 or 2 ohms, start checking the cabling, connectors, and any earth attachment points backwards towards the battery from the socket. 5. If globe and earth are OK, put the fuse back in and, with multimeter on 20V range, start checking the power through the cabling and switches. A good place to start is inside the headlamp shell (most lighting power routes through this area. Check the

Version 3.0

Nov 2009

Page 25

connectors on the back of the lighting switch for 12V from the battery, then work your way forward to the socket that doesnt work.

7. Horn
The horn is a fairly simple electro-mechanical device that uses a switched electromagnet to vibrate a plate, creating sound waves. Diagram 9 depicts a simple horn construction.

Vibrating plate Contacts

Casing

Electromagnet

DIAGRAM 9

When power is first applied (you press the horn button), the electromagnet energises, and draws the steel vibrating plate towards its core. This causes a rod mounted on the underside of the vibrating plate to break the electrical contacts apart, and current stops flowing through the electromagnet. The steel vibrating plate snaps back to its rest position, and the electrical contact meet and again allow current to flow through the electromagnet. This cycle continues until the current is switched off externally (ie you stop pressing the horn button). The vibration of the plate is at such a frequency as to create sound waves. Most horns have an adjustment screw on the rear of the case to adjust the tone of the horn. This screw merely adjusts the position of the upper contact, thus changing the amount of movement of the vibrating plate required to make/break the contact.

7.1

Fault finding a horn

The horn is most likely to break down due to three causes: Internal corrosion due to exposure to the weather usually caused by the breakdown of sealing materials around the case and vibrating plate. Maladjustment or misalignment of the contacts, due to the adjustment screw moving with vibration. Broken cabling and poor connections to the horn and horn switch. To test the horn, take the wires off the horn connectors (note which way they go), and using a multimeter on resistance range, check for resistance between the two connectors on the horn casing. You should see around 16 or 20 . If infinite resistance, you can try rotating the adjustment screw on the back of the casing until you get a reading. Most likely youll need to take it apart. Take note of which way the plate and the case are oriented together a couple of dots of liquid paper can help align when putting it back together. Take the plate

Version 3.0

Nov 2009

Page 26

off, and check the internal connection and contacts, as well as the position of the adjustment screw. Remember to seal the case against the weather if a gasket is not available, use a thin bead of silicon. Remember, you should have a low resistance reading when the horn is not operating. If the adjustment screw is adjusted correctly, you should be able to press on the vibrating plate by using fingers, and cause the contacts to break the connection, making the meter read infinite resistance. Let the plate go, and the reading should return to low resistance. Connect up the power and earth cables, and test. Then adjust the screw to give the tone you require. Be aware that the more the plate has to move (the lower the tone), the more average power will be required to operate the horn. If, when you connect it all back up and press the horn button, you just hear a click when you press the horn button, and another when you let it go, the adjustment screw is maladjusted, and the vibrating plate is not breaking the contacts.

8. A Few Tips
If your motorcycle electrical system is constantly blowing fuses, and youre having trouble tracing the fault, wire in a 20 Watt globe in place of the fuse. When a short is present somewhere in the electrical system, the globe will light up. Start disconnecting components one-by-one (eg rectifier, zener, coils, etc) until the globe stops glowing, and youve found the faulty area. The tube-type connectors used to connect the male bullet connectors together are notorious for poor connections. Corrosion and broken metal inside the plastic covers are common. Frayed wires have less conductors to carry current, and therefore add resistance to any circuit, which results in reduced performance. Fix or replace any frayed wires, especially near connectors, and in high-current circuits such as charging and lighting. Wires that have worn insulation may cause shorts, or allow moisture into the conductors, causing corrosion. Repair or replace wires with worn or missing insulation. Heatshrink tubing can be handy in these situations. If the battery moves around in the holder, theres a possibility of shorts to the seat pan, or to the buckle on the hold-down strap from the active battery terminal. High density foam will secure the battery in the holder, but make sure you dont block the air intakes behind the side covers. Halogen headlamps provide better lighting, but also generate more heat. Be wary of melted wires behind the halogen lamp connector in the headlamp shell. Brake light globes have a tendency, due to the mounting rubbers, to wobble about a bit. This causes either filaments to fail, or the glass to break on surrounding metalwork (eg reflector mounting bolt). If you place a small dob of silicon between the globe and the reflector, it will stop the globe vibrating, and prolong the life of the globe. When working on the electrical system, have a blown-up photocopy (A3 size) of the schematic handy, so you can mark off whats been checked, and note voltages and other readings at certain points.

Version 3.0

Nov 2009

Page 27

Whenever electrical wires pass through metal, they should have a grommet or similar protective covering around the metal edges, to stop the plastic covering on the wires being worn away and the wire shorting to earth. Some owners install a second fuse between the positive terminal of the battery and frame/earth. While this can protect the battery and the loom in cases where the negative terminal shorts to earth, it also adds another component that can break down and leave you stranded. Always carry extra fuses, taped to the wires near the battery or to the fuse-holder itself.

P.S. Hopefully this information will help someone to keep their Triumph running and safe. Please feel free to use it as a guide, but remember many of the older bikes have gone through many owners, and thus may be fitted with many different components. If you have any comments or suggestions for future versions, please drop me a line using the TriumphRat.net PM system. Pete.

Version 3.0

Nov 2009

Page 28