You are on page 1of 60

Phelps Dodge International (Thailand) Limited

Building Wires & Interior Wires

An ISO 9001, ISO 14001 and OHSAS 18001 Certified Company


Company Profile

Phelps Dodge International (Thailand) Limited is part of
General Cable Corporation – the world’s second-largest
manufacturer of wires and cables with over 45 production
facilities in 22 countries around the globe. The group’s
strength lies in its superior research and development,
leading edge engineering and manufacturing operations, the
broadest product range in the industry, and highly-efficient
logistic capabilities. Plus, with a strong group of associates
seamlessly teaming up to satisfy customers worldwide, wire
and cable products from General Cable and PDTL have become
the undisputed preferred choice among customer worldwide.

Milestones
1968 Established Phelps Dodge Thailand Limited
Started production at the Samrong plant.
1992 Started production at the Bangplee plant.
1993 Began operating the state-of-the-art VCV Line, to
produce Extra High Voltage Power Cable for up to 230 kV.
1995 Obtained the ISO 9001 from British Approvals
Service for Cables (BASEC) - first in Thailand.
1997 Obtained an additional ISO 9001 certificate from the Thai
Industrial Standards Institute.
1999 Achieved the ISO 14001 from British Approvals
Service for Cables (BASEC)
1999 Started operating the Rayong Building Wire Plant, and
achieved ISO 9002 from Underwriters Laboratories Inc.
(UL)
2000 Transfered the ISO 9001 and ISO 14001 registrations
from British Approvals Service for Cables (BASEC) to
Under writers Laboratories Inc. (UL)
Transfered the ISO 9001 registration from Thai Industrial
Standards Institute (TISI) to Management System
Certification (Thailand) (MASCI)
2001 The Bangplee plant obtained its OHSAS 18001 certificate
from Underwriters Laboratories. (UL)
2002 The Bangplee and Rayong plants obtained ISO 9001
Version 2000 from Underwriters Laboratories (UL) and
Management System Certification (Thailand) (MASCI)
2003 The Rayong plant obtained its ISO 14001 and OHSAS
18001 certificate from Underwriter Laboratories (UL)
2005 Won the 2005 Chairman’s Health and Safety Award in a
category of Large facility. This reward is presented
annually to the company which has a safety record that
stands out as being among the best in the corporation
2007 Become part of General Cable Corporation.
2008 Changed its name to Phelps Dodge International
(Thailand) Limited.

The highest Quality and Reliability


Production Facilities
Bangplee Plant: Product Lines
Phelps Dodge International (Thailand) Limited facility at Bangplee,
Samutprakarn, is one of the most modern wire and cable plants in 1. Bare Copper and Aluminum Conductor
Southeast Asia providing world class manufacturing capabilities. Built 2. Building Wires and Interior Wires
in response to the increase in demand for wire and cable products, the 3. Telecommunications Cables
plants incorporates the latest technology and highest quality control 4. High Voltage and Extra High Voltage Power
standards throughout the production process. At present, the complex Cable with and without Lead Sheath
features a vertical continuous vulcanization (VCV) tower, which is the 5. Low Voltage Power Cables and Control Cables
first vertical crosslink high voltage insulating unit in southeast Asia 6. Low Smoke Zero Halogen and Fire Resistant
and one of the few of its kind in the world. The facility can also Cables
produce low voltage power cables, internal and external
telecommunications cables, and local area network cable.
Our value customers
The Company has 2 more Horizontal CV lines with most modern High
Voltage Test Laboratory. Plant has been designed to take ultimate Phelps Dodge International (Thailand) Limited is
care for dust free environment and production high quality Medium capable of manufacturing world class quality wire
Voltage, High Voltage and Extra High Voltage XLPE Cables and cable at competitive prices with strict global
standards. The company is trusted to supply wire
and cable to local state enterprises, distributors
Rayong Plant: and various reputable firms.
Phelps Dodge International (Thailand) Limited facility at Rayong
specializes in automated, high-volume building wire production at a Electricity Generating Authority of Thailand (EGAT)
world-class level. It will consolidate all Phelps Dodge International Provincial Electricity Authority (PEA)
(Thailand) Limited building wire manufacturing into a single, state-of- Metropolitan Electricity Authority (MEA)
art facility. It would also enable Phelps Dodge International (Thailand) TOT Public Company Limited (TOT)
Limited future expansion into flexible cords (welding cables, elevator CAT Telecom Public Company Limited (CAT)
cables, etc.) and the extrusion of more advanced insulation materials
(flame retardant, low halogen emission, etc.). Phelps Dodge International (Thailand) Limited has
been exporting its quality cable to the U.S., Middle
Quality Policy & Assurance East, Asia and Indochina for many years.
Phelps Dodge International (Thailand) Limited follows continuous and
strict procedures throughout every production process. Our quality
control begins with the careful scrutinization of raw materials and
continues to the testing of final products; where every finished length
of cable must also pass a rigorous test to meet required specifications
before it is shipped to our customers.

As part of our standard operating practice, these reliability tests, in
many cases surpass general industry standard. In order to cope with
the volume and accuracy required of such units introduced in
Thailand.

In fact, Phelps Dodge International (Thailand) Limited is the only
supplier in Thailand with complete in-house facilities for testing power
cable up to 400 kV.

Phelps Dodge International (Thailand) Limited has got its certification
type test from International Independent Laboratories such as KEMA,
Cable Technology Lab, etc. For LSFOH Cable, Fire Resistant Cable,
Medium Voltage, High Voltage and Extra High Voltage XLPE Cables.

Quality Policy
It is the policy of Phelps Dodge International (Thailand) Limited. To
manufacture and market products which are of the highest quality
and reliability. It is also a Phelps Dodge International (Thailand)
Limited. Policy to comply with iso 9001, all applicable regulatory
requirements, customer satisfaction and continually improve the
effectiveness of the quality management system by establishing
and reviewing annual quality objectives and targets.
ISO 9001 Certification
(Maneeya office, Bangplee and Rayong Plant)

In August 1995, Phelps Dodge International (Thailand)
Limited was proud to be the first electric wires and cable
firm in Thailand to obtain the International ISO 9001
quality standard certificate for all its factories. The
company received the ISO 9001 certificate from the
British Approvals Services for Cables (BASEC), a
standard accreditation authority which has been testing
cables for over 20 years.

For another step of global competitiveness, in
September 2000, Phelps Dodge International (Thailand)
Limited had accomplished ISO 9001 standard from UL
(Underwriters Laboratories Inc.) in replacement of the
former certificate from BASEC. With strict compliance to
the regulatory outlines and practice of UL, Phelps Dodge
International (Thailand) Limited committed to the Environmental, Occupational
customer satisfaction for every product and services
offered. Health and Safety Policy

Not only international accreditation, Phelps Dodge At Phelps Dodge International (Thailand) Limited, as a
International (Thailand) Limited also obtained ISO 9001 manufacturer of wires & cables,
certification from the Thai Industrial Standards Institute
(TISI) for the local approval in February 1997. In February • We believe that all injuries and occupational illness can
2000, TISI had empowered MASCI (Management System be prevented. Therefore, for the well being of all
Certification Institute Thailand) to evaluate and issue ISO employees, the effective occupational health and safety
certificate to the firms that have fullfilled the management is a basis of the company’s policy
requirements and regulations. • We believe and realize the importance of the world’s
environmental protection through efficient utilization of
natural resources and minimizing environmental
impact while contributing to sustainable development.
ISO 9001 Version 2000 Certification • We also believe that environment, occupational health
(Maneeya office, Bangplee and Rayong Plant) and safety must be thoroughly integrated with our
effort to produce high quality products at competitive
In order to improve the effectiveness of the quality price.
management system and enhance customer satisfaction
by meeting customer requirements, the quality Phelps Dodge International (Thailand) Limited, therefore,
management systems of Maneeya office, Bangplee and has established and maintained an environmental,
Rayong Plant were integrated and upgraded to ISO 9001 occupational health and safety management system
version 2000. We, therefore, obtained ISO 9001 : 2000 according to ISO 14001, OHSAS 18001, TIS 18000 and BS
certification from Management System Certification 8800 and ensure that it
(Thailand) (MASCI) and Underwriters Laboratories (UL)
in March and April 2002 respectively. 1. complies with relevant environmental, occupational
health and safety legislation and regulations, and with
Phelps Dodge International (Thailand) Limited is other requirements to which the company subscribes;
recognized as the premier electric wires and cables
manufacturer that achieved both local and international 2. provides the frameworks for setting and reviewing
standards. annual objectives and targets and is implementing
programs to
• continuously improve environmental, occupational
health and safety performance and prevention of
accidents and pollution.
• minimize process emissions, waste and improve
resource utilization.
• protect the health and safety of our employees and
people who may be affected by the company’s
activities.
• devise technological solutions that are sound and
cost effective for the environment, occupational
health and safety.
Quick Guide to the selection of Building Wires & Interior Wires
PAGE BUILDING WIRES AND PHELPS DODGE
NO. INTERIOR WIRES & TYPE LETTER STANDARD CABLE NAME APPLICATION
CABLES CODE NAME

1 CSC TIS 64-2517 Bare copper stranded Aerial power transmission


conductor (Hard Drawn) and distribution line

2 CSC TIS 11-2531 Bare copper stranded Aerial power transmission


conductor (Soft Drawn) and distribution line

3 PD-IV TIS 11-2531 300 V copper cdr., PVC residential wiring


table 1 insulated cable

5 PD-VAF TIS 11-2531 300 V copper cdr., PVC residential surface wiring
table 2 ins., PVC jacketed cable
(flat type)

8 PD-VVR TIS 11-2531 300 V multicore copper cdr., residential surface wiring
table 3 PVC ins., PVC jacketed
cable

9 PD-THW TIS 11-2531 750 V copper cdr., PVC ins., fixed wiring for large
table 4 building and industry

11 PD-VV TIS 11-2531 750 V copper cdr., PVC ins., fixed installation
table 5 PVC jacketed cable

12 PD-VVF TIS 11-2531 750 V copper cdr., PVC ins., fixed installation
table 5 PVC jacketed cable
(flat type)

13 PD-NYY TIS 11-2531 750 V copper cdr., PVC ins., fixed installation
table 6 PVC jacketed cable

19 PD-NYY TIS 11-2531 750 V multicore copper cdr., feeder, branch circuit cable
table 7 PVC ins., PVC inner jacket,
PVC outer jacketed cable

21 PD-NYY-N TIS 11-2531 750 V multicore copper cdr., feeder, branch circuit cable
table 8 PVC ins., PVC inner jacket, (for 3 phase, 4 wire system)
PVC outer jacketed cable
with neutral

25 PD-VCT TIS 11-2531 750 V multicore copper cdr., mobile-electrical equipment


table 9 PVC ins., PVC inner jacket, or machine tool wiring
PVC outer jacketed cable
(flexible conductor)

26 PD-VTF TIS 11-2531 300 V copper cdr., PVC ins. small indoor electrical
table 10 (twist type, flexible cdr.) appliance

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Revision 2 : July 16, 2008
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Quick Guide to the selection of Building Wires & Interior Wires
PAGE BUILDING WIRES AND PHELPS DODGE
NO. INTERIOR WIRES & TYPE LETTER STANDARD CABLE NAME APPLICATION
CABLES CODE NAME

27 PD-VFF TIS 11-2531 300 V copper cdr., PVC small indoor electrical
table 10 ins. (flat twin, flexible cdr.) appliance

28 PD-VSF TIS 11-2531 300 V copper cdr., PVC small electrical


table 10 insulated single core appliance
(flexible cdr.)

29 PD-VAF-G TIS 11-2531 300 V copper cdr., PVC residential surface wiring
table 11 ins. PVC jacketed cable
with ground (flat type)

33 PD-VVR-G TIS 11-2531 300 V copper cdr., PVC fixed installation


table 12 ins. PVC jacketed cable with ground system
with ground

34 PD-VVF-G TIS 11-2531 750 V copper cdr., PVC surface wiring on wall
table 13 insulated, PVC jacket ceiling or floor
with ground (flat type)

35 PD-NYY-G TIS 11-2531 750 V copper cdr., PVC fixed installtion


table 14 ins., PVC jacked cable with ground system
with ground

41 PD-VCT-G TIS 11-2531 750 V copper cdr., PVC


mobile-electrical equipment
table 15 insulated. PVC inner and
or machine tool wiring
outer jacket with ground
(flexible conductor)

44 PD-VFF-G TIS 11-2531 300 V copper cdr., PVC small indoor electrical
table 16 ins. with ground appliance with ground
(flat type, flexible cdr.) system

45 PD-VAFF TIS 11-2531 300 V copper cdr., PVC For surface or above
table 17 PVC jacketed cable ceiling wiring or direct
(flat type, flexible cdr.) embeded in plaster

47 XHHW-2 UL 44 600 V Aluminum Alloy cdr., general purpose building


UL recognized cross-linked wire for installation in air,
polyethylene ins. duct, conduit or other
raceways.

48 XHHW, UL 44 600 V copper cdr., general purpose building


XHHW-2 UL recognized cross-linked wire for installation in air,
polyethylene insulated wire duct, conduit or other
raceways.

49 THHN-THWN UL 83 600 V copper cdr., general purpose building


UL 758 UL recognized thermoplastic wire for services, feeders
UL 1063 insulated wire and branch circuit conduit
and raceway

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Revision 2 : July 16, 2008
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
PHELPS DODGE CONDUCTOR TYPE CSC
BARE COPPER STRANDED CONDUCTOR
Application :
Aerial power transmission and
distribution line.

Reference Standard :
TIS 64-2517

HARD DRAWN COPPER WIRES

Conductor :
Hard drawn copper wire,
concentric stranded conductor
Sizes 10 mm2 up to 500 mm2

Maximum
Nominal Number & Allowable Cable
Overall Conductor Breaking Standard
Sectional Diameter Ampacities Weight
Diameter Resistance Strength Packing
Area of Wire In Free Air kg / km
mm at 20°C (kgf) (m)
mm2 No. / mm (A)
/ km
10 7/1.35 4.05 1.80548 438 90 90 1,000/R
16 7/1.70 5.10 1.13857 694 125 143 1,000/R
25 7/2.14 6.42 0.71851 1,076 160 227 1,000/R
35 7/2.52 7.56 0.51815 1,459 200 314 1,000/R
50 7/3.02 9.06 0.35896 2,095 250 452 1,000/R
50 19/1.78 8.90 0.38252 2,021 250 428 1,000/R
70 19/2.14 10.70 0.26466 2,921 310 618 1,000/R
95 19/2.52 12.60 0.19183 3,961 380 858 1,000/R
120 19/2.85 14.25 0.14922 5,067 440 1,097 1,000/R
150 37/2.25 15.75 0.12384 6,289 510 1,334 1,000/R
185 37/2.52 17.64 0.09813 7,713 585 1,673 1,000/R
240 61/2.25 20.25 0.07528 10,369 700 2,200 1,000/R
300 61/2.52 22.68 0.06002 12,717 800 2,760 1,000/R
400 61/2.85 25.65 0.04692 16,266 900 3,350 1,000/R
500 61/3.20 28.80 0.03703 20,506 1,110 4,451 1,000/R

R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 01
PHELPS DODGE CONDUCTOR TYPE CSC
BARE ANNEALED COPPER STRANDED CONDUCTOR
Application :
Aerial power transmission and
distribution line.

Reference Standard :
TIS 11-2531

SOFT DRAWN (ANNEALED)


COPPER WIRES

Conductor :
Soft drawn copper wire, concentric
stranded conductor
Sizes 10 mm2 up to 500 mm2

Maximum
Nominal Number & Allowable Cable
Overall Conductor Standard
Sectional Diameter Ampacities Weight
Diameter Resistance Packing
Area of Wire In Free Air (approx)
mm at 20°C m
mm2 No. / mm A kg / km
/ km
10 7/1.35 4.05 1.83 90 90 1,000/R
16 7/1.70 5.10 1.15 125 143 1,000/R
25 7/2.14 6.42 0.727 160 227 1,000/R
35 19/1.53 7.65 0.524 200 314 1,000/R
50 19/1.78 8.90 0.387 250 428 1,000/R
70 19/2.14 10.70 0.268 310 618 1,000/R
95 19/2.52 12.60 0.193 380 858 1,000/R
120 37/2.03 14.21 0.153 440 1,097 1,000/R
150 37/2.25 15.75 0.124 510 1,334 1,000/R
185 37/2.52 17.64 0.0991 585 1,673 1,000/R
240 61/2.25 20.25 0.0754 700 2,200 1,000/R
300 61/2.52 22.68 0.0601 800 2,760 1,000/R
400 61/2.85 25.65 0.0470 900 3,350 1,000/R
500 61/3.20 28.80 0.0366 1,110 4,451 1,000/R

R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
02 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-IV
300 V 70oC PVC INSULATED, SINGLE CORE
Application :
Building wiring, for installation on
insulator or in raceway, dry and wet
location.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.

Reference Standard :
TIS 11-2531 TABLE 1
Conductor PVC insulation

Construction :
Conductor : Annealed copper,
solid or stranded
Sizes 0.5 mm2 up to 150 mm2

Insulation : Polyvinyl chloride (Any


colour as requested)

Allowable Minimum
Nominal Number & Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Weight
Diameter Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation (approx)
mm 40°C at 70°C m
mm2 No. / mm mm kg / km
A M - km
0.5 PD-IV 0.5 1/0.80 0.6 2.6 9 0.0146 8.5 100/C
1 PD-IV 1 1/1.13 0.6 2.9 14 0.0115 14 100/C
1 PD-IV 1 7/0.40 0.6 3.1 14 0.0110 14 100/C
1.5 PD-IV 1.5 1/1.38 0.6 3.2 18 0.0100 19 100/C
1.5 PD-IV 1.5 7/0.50 0.6 3.4 18 0.0094 19 100/C
2.5 PD-IV 2.5 1/1.78 0.7 3.8 25 0.0092 31 100/C
2.5 PD-IV 2.5 7/0.67 0.7 4.1 25 0.0084 31 100/C
4 PD-IV 4 1/2.25 0.8 4.5 34 0.0086 48 100/C
4 PD-IV 4 7/0.85 0.8 4.9 34 0.0078 48 100/C
6 PD-IV 6 7/1.04 0.8 5.6 44 0.0066 70 100/C
10 PD-IV 10 7/1.35 1.0 7.0 62 0.0064 120 100/C
16 PD-IV 16 7/1.70 1.0 8.2 84 0.0053 180 100/C
25 PD-IV 25 7/2.14 1.2 10.0 113 0.0051 280 100/C
35 PD-IV 35 19/1.53 1.2 11.5 141 0.0043 380 100/C
50 PD-IV 50 19/1.78 1.4 13.0 171 0.0044 530 500/R
70 PD-IV 70 19/2.14 1.4 15.0 221 0.0037 720 500/R
95 PD-IV 95 19/2.52 1.6 17.5 271 0.0036 990 500/R
120 PD-IV 120 37/2.03 1.6 19.0 315 0.0032 1,230 500/R
150 PD-IV 150 37/2.25 1.8 21.5 365 0.0033 1,510 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 03
PHELPS DODGE CONDUCTOR TYPE PD-VAF (MEA TYPE B)
300 V 70 oC PVC INSULATED AND SHEATHED FLAT TYPE, TWO CORE
Application :
For surface or above ceiling wiring
or direct embeded in plaster

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.

Reference Standard : Conductor


TIS 11-2531 TABLE 2

PVC insulation

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 0.5 mm up to 35 mm
PVC sheath
Insulation : Heat resistance polyvinyl
chloride (Gray and Black colour)

Sheath : Heat resistance polyvinyl


chloride (White colour)

Allowable Minimum
Nominal Number & Thickness Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of of Weight
Dimension Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath (approx)
mm 40°C at 70°C m
mm2 No. / mm mm mm kg / km
A M - km
2 x 0.5 PD-VAF 0.5 1/0.80 0.6 0.9 4.4x6.8 8 0.0146 37 100/C
2x1 PD-VAF 1 1/1.13 0.6 0.9 4.8x7.4 13 0.0115 50 100/C
2 x 1 PD-VAF 1 7/0.40 0.6 0.9 5.0x7.8 13 0.0110 50 100/C
2 x 1.5 PD-VAF 1.5 1/1.38 0.6 1.2 5.8x8.6 17 0.0100 70 100/C
2 x 1.5 PD-VAF 1.5 7/0.50 0.6 1.2 6.0x9.2 17 0.0094 70 100/C
2 x 2.5 PD-VAF 2.5 1/1.78 0.7 1.2 6.4x10.0 23 0.0092 100 100/C
2 x 2.5 PD-VAF 2.5 7/0.67 0.7 1.2 6.8x10.5 23 0.0084 100 100/C
2x4 PD-VAF 4 1/2.25 0.8 1.2 7.2x11.5 30 0.0086 140 100/C
2x4 PD-VAF 4 7/0.85 0.8 1.2 7.6x12.0 30 0.0078 140 100/C
2x6 PD-VAF 6 7/1.04 0.8 1.2 8.2x13.5 40 0.0066 200 100/C
2 x 10 PD-VAF 10 7/1.35 0.9 1.2 9.4x16.0 55 0.0059 300 100/C
2 x 16 PD-VAF 16 7/1.70 1.0 1.2 11.0x18.5 74 0.0053 440 100/C
2 x 25 PD-VAF 25 7/2.14 1.2 1.4 13.0x22.5 97 0.0051 690 500/R
2 x 35 PD-VAF 35 19/1.53 1.2 1.4 14.5x25.0 120 0.0043 900 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
04 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VAF
300 V 70oC PVC INSULATED AND SHEATHED FLAT TYPE, THREE CORE
Application :
Building wiring for installation on
insulator or in raceway, dry and wet
location.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.

Reference Standard : Conductor


TIS 11-2531 TABLE 2
PVC insulation

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 0.5 mm up to 16 mm PVC sheath

Insulation : Heat resistance


polyvinyl chloride (Gray, Black and
Red colour)

Sheath : Heat resistance polyvinyl


chloride (White colour)

Allowable Minimum
Nominal Number & Thickness Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of of Weight
Dimension Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath (approx)
mm 40°C at 70°C m
mm2 No. / mm mm mm kg / km
A M - km
3 x 0.5 PD-VAF 0.5 1/0.80 0.6 0.9 4.4x9.0 6.5 0.0146 41 100/C
3 x 1 PD-VAF 1 1/1.13 0.6 0.9 4.8x10.0 11.5 0.0115 55 100/C
3 x 1 PD-VAF 1 7/0.40 0.6 0.9 5.0x10.5 11.5 0.0110 55 100/C
3 x 1.5 PD-VAF 1.5 1/1.38 0.6 1.2 5.8x11.5 15 0.0100 77 100/C
3 x 1.5 PD-VAF 1.5 7/0.50 0.6 1.2 6.0x12.5 15 0.0094 77 100/C
3 x 2.5 PD-VAF 2.5 1/1.78 0.7 1.2 6.4x13.5 21 0.0092 110 100/C
3 x 2.5 PD-VAF 2.5 7/0.67 0.7 1.2 6.8x14.5 21 0.0084 110 100/C
3 x 4 PD-VAF 4 1/2.25 0.8 1.2 7.2x16.0 28 0.0086 154 100/C
3 x 4 PD-VAF 4 7/0.85 0.8 1.2 7.6x16.5 28 0.0078 154 100/C
3 x 6 PD-VAF 6 7/1.04 0.8 1.2 8.2x18.5 36 0.0066 220 100/C
3 x 10 PD-VAF 10 7/1.35 0.9 1.2 9.4x22.0 50 0.0059 363 500/R
3 x 16 PD-VAF 16 7/1.70 1.0 1.4 11.5x26.5 66 0.0053 484 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 05
PHELPS DODGE CONDUCTOR TYPE PD-VVR
300 V 70oC PVC INSULATED AND SHEATHED, TWO CORE
Application :
Exposed wiring in air or use in
raceway wet or dry location, direct
burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts. Conductor

Reference Standard : PVC insulation


TIS 11-2531 TABLE 3

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 0.5 mm up to 35 mm PVC sheath

Insulation : Heat resistance polyvinyl


chloride (Gray and Black colour)

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Allowable Minimum
Nominal Number & Thickness Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of of Weight
Dimension Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath (approx)
2 mm 40°C at 70°C (m)
mm No. / mm mm mm kg / km
A M - km
2 x 0.5 PD-VVR 0.5 1/0.80 0.6 0.9 6.8 8 0.0146 48 500/R
2x1 PD-VVR 1 1/1.13 0.6 0.9 7.6 13 0.0115 65 500/R
2x1 PD-VVR 1 7/0.40 0.6 0.9 8.0 13 0.0110 65 500/R
2 x 1.5 PD-VVR 1.5 1/1.38 0.6 1.2 8.8 17 0.0100 90 500/R
2 x 1.5 PD-VVR 1.5 7/0.50 0.6 1.2 9.2 17 0.0094 90 500/R
2 x 2.5 PD-VVR 2.5 1/1.78 0.7 1.2 10.0 23 0.0092 130 500/R
2 x 2.5 PD-VVR 2.5 7/0.67 0.7 1.2 11.0 23 0.0084 130 500/R
2x4 PD-VVR 4 1/2.25 0.8 1.2 11.5 30 0.0086 180 500/R
2x4 PD-VVR 4 7/0.85 0.8 1.2 12.5 30 0.0078 180 500/R
2x6 PD-VVR 6 7/1.04 0.8 1.2 13.5 40 0.0066 260 500/R
2 x 10 PD-VVR 10 7/1.35 0.9 1.2 16.0 55 0.0059 390 500/R
2 x 16 PD-VVR 16 7/1.70 1.0 1.4 19.0 74 0.0053 580 500/R
2 x 25 PD-VVR 25 7/2.14 1.2 1.4 22.5 97 0.0051 870 500/R
2 x 35 PD-VVR 35 19/1.53 1.2 1.4 25.5 120 0.0043 1,130 500/R
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
06 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VVR
300 V 70oC PVC INSULATED AND SHEATHED, THREE CORE
Application :
Exposed wiring in air or use in
raceway wet or dry location, direct
burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not Conductor
exceed 300 volts.
PVC insulation
Reference Standard :
TIS 11-2531 TABLE 3

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 0.5 mm up to 35 mm PVC sheath

Insulation : Heat resistance


polyvinyl chloride (Gray, Black and
Red colour)

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Allowable Minimum
Nominal Number & Thickness Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of of Weight
Dimension Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath (approx)
mm 40°C at 70°C (m)
mm 2
No. / mm mm mm kg / km
A M - km
3 x 0.5 PD-VVR 0.5 1/0.80 0.6 0.9 7.2 6.5 0.0146 55 500/R
3 x 1 PD-VVR 1 1/1.13 0.6 0.9 8.0 11.5 0.0115 80 500/R
3 x 1 PD-VVR 1 7/0.40 0.6 0.9 8.4 11.5 0.0110 80 500/R
3 x 1.5 PD-VVR 1.5 1/1.38 0.6 1.2 9.2 15 0.0100 110 500/R
3 x 1.5 PD-VVR 1.5 7/0.50 0.6 1.2 9.6 15 0.0094 110 500/R
3 x 2.5 PD-VVR 2.5 1/1.78 0.7 1.2 10.5 21 0.0092 160 500/R
3 x 2.5 PD-VVR 2.5 7/0.67 0.7 1.2 11.5 21 0.0084 160 500/R
3x4 PD-VVR 4 1/2.25 0.8 1.2 12.5 28 0.0086 230 500/R
3x4 PD-VVR 4 7/0.85 0.8 1.2 13.0 28 0.0078 230 500/R
3 x 6 PD-VVR 6 7/1.04 0.8 1.2 14.5 36 0.0066 330 500/R
3 x 10 PD-VVR 10 7/1.35 0.9 1.2 17.0 50 0.0059 490 500/R
3 x 16 PD-VVR 16 7/1.70 1.0 1.4 20.0 66 0.0053 740 500/R
3 x 25 PD-VVR 25 7/2.14 1.2 1.8 25.0 84 0.0051 1,180 500/R
3 x 35 PD-VVR 35 19/1.53 1.2 1.8 28.0 104 0.0043 1,530 500/R
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 07
PHELPS DODGE CONDUCTOR TYPE PD-VVR
300 V 70oC PVC INSULATED AND SHEATHED, FOUR CORE
Application :
Exposed wiring in air or use in
raceway wet or dry location, direct
burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not Conductor
exceed 300 volts.
PVC insulation
Reference Standard :
TIS 11-2531 TABLE 3

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 0.5 mm up to 35 mm

Insulation : Heat resistance polyvinyl


chloride (Gray, Black, Red and Blue PVC sheath
colour)

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Allowable Minimum
Nominal Number & Thickness Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of of Weight
Dimension Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath (approx)
mm 40°C m
mm2 No. / mm mm mm kg / km
A M - km
4 x 0.5 PD-VVR 0.5 1/0.80 0.6 0.9 7.8 6.5 0.0146 65 500/R
4 x 1 PD-VVR 1 1/1.13 0.6 0.9 8.6 11.5 0.0115 100 500/R
4 x 1 PD-VVR 1 7/0.40 0.6 0.9 9.0 11.5 0.0110 100 500/R
4 x 1.5 PD-VVR 1.5 1/1.38 0.6 1.2 10.0 15 0.0100 130 500/R
4 x 1.5 PD-VVR 1.5 7/0.50 0.6 1.2 10.5 15 0.0094 130 500/R
4 x 2.5 PD-VVR 2.5 1/1.78 0.7 1.2 11.5 21 0.0092 190 500/R
4 x 2.5 PD-VVR 2.5 7/0.67 0.7 1.2 12.5 21 0.0084 190 500/R
4x4 PD-VVR 4 1/2.25 0.8 1.2 13.5 28 0.0086 290 500/R
4x4 PD-VVR 4 7/0.85 0.8 1.2 14.0 28 0.0078 290 500/R
4x6 PD-VVR 6 7/1.04 0.8 1.2 15.5 36 0.0066 410 500/R
4 x 10 PD-VVR 10 7/1.35 0.9 1.4 19.0 50 0.0059 640 500/R
4 x 16 PD-VVR 16 7/1.70 1.0 1.4 22.0 66 0.0053 940 500/R
4 x 25 PD-VVR 25 7/2.14 1.2 1.8 27.5 84 0.0051 1,490 500/R
4 x 35 PD-VVR 35 19/1.53 1.2 1.8 30.5 104 0.0043 1,950 500/R
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
08 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-THW (MEA TYPE A)
750 V 70oC PVC INSULATED SINGLE CORE
Application :
Building wiring for installation on
insulator or in raceway, dry and wet
location.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts.

Reference Standard :
TIS 11-2531 TABLE 4 Conductor PVC insulation

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 0.5 mm up to 500 mm

Insulation : Heat resistance polyvinyl


chloride (Any colour as requested)

Allowable Minimum
Thickness Cable
Nominal Number & Overall Ampacities Insulation Standard
PHELPS DODGE of Weight
Aectional Area Diameter of Wire Diameter Free Air Resistance Packing
TYPE LETTER insulation (approx)
mm2 No. / mm mm 40°C at 70°C m
mm kg / km
A M - km
0.5 PD-THW 0.5 1/0.80 0.8 3.0 11 0.0175 11 100/C
1 PD-THW 1 1/1.13 0.8 3.3 16 0.0141 17 100/C
1 PD-THW 1 7/0.40 0.8 3.5 16 0.0135 17 100/C
1.5 PD-THW 1.5 1/1.38 0.8 3.6 21 0.0123 22 100/C
1.5 PD-THW 1.5 7/0.50 0.8 3.8 21 0.0116 22 100/C
2.5 PD-THW 2.5 1/1.78 0.8 4.0 29 0.0102 31 100/C
2.5 PD-THW 2.5 7/0.67 0.8 4.3 29 0.0093 31 100/C
4 PD-THW 4 1/2.25 0.9 4.8 39 0.0094 50 100/C
4 PD-THW 4 7/0.85 0.9 5.2 39 0.0085 50 100/C
6 PD-THW 6 7/1.04 0.9 5.8 51 0.0073 75 100/C
10 PD-THW 10 7/1.35 1.1 7.2 70 0.0069 120 100/C
16 PD-THW 16 7/1.70 1.1 8.4 96 0.0057 180 100/C
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 09
PHELPS DODGE CONDUCTOR TYPE PD-THW (MEA TYPE A)
750 V 70oC PVC INSULATED SINGLE CORE
Application :
Building wiring for installation on
insulator or in raceway, dry and wet
location.

Classification :
Maximum conductor
o
temperature 70 C Circuit voltage
does not exceed 750 volts.

Reference Standard :
TIS 11-2531 TABLE 4 Conductor PVC insulation

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 0.5 mm up to 500 mm

Insulation : Heat resistance polyvinyl


chloride (Any colour as requested)

Allowable Minimum
Nominal Number & Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Weight
Dimension Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation (approx)
mm 40°C at 70°C m
mm2 No. / mm mm kg / km
A M - km
25 PD-THW 25 7/2.14 1.3 10.5 127 0.0054 290 100/C
35 PD-THW 35 19/1.53 1.3 11.5 157 0.0047 380 100/C
50 PD-THW 50 19/1.78 1.5 13.5 191 0.0046 540 500/R
70 PD-THW 70 19/2.14 1.5 15.5 244 0.0039 720 500/R
95 PD-THW 95 19/2.52 1.7 18.0 297 0.0038 1,000 500/R
120 PD-THW 120 37/2.03 1.7 19.5 345 0.0034 1,240 500/R
150 PD-THW 150 37/2.25 1.9 21.5 397 0.0034 1,520 500/R
185 PD-THW 185 37/2.52 2.1 24.0 453 0.0034 1,900 500/R
240 PD-THW 240 61/2.25 2.3 27.0 535 0.0033 2,480 500/R
300 PD-THW 300 61/2.52 2.5 30.0 617 0.0032 3,100 500/R
400 PD-THW 400 61/2.85 2.7 33.5 741 0.0030 3,950 500/R
500 PD-THW 500 61/3.20 3.1 38.0 854 0.0031 5,150 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
10 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VV (MEA TYPE B)
750 V 70oC PVC INSULATED AND SHEATHED, SINGLE CORE
Application :
For fixed installation in wet or dry
location. The cable is suitable for
surface wiring or concealed wiring
in wooden partition.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts. Conductor

Reference Standard : PVC insulation


TIS 11-2531 TABLE 5

Construction :
Conductor : Annealed copper, solid PVC sheath
or stranded
2 2
Sizes 1 mm up to 35 mm

Insulation : Heat resistance polyvinyl


chloride (Gray colour)

Sheath : Heat resistance polyvinyl


chloride (White colour)

Nominal Number & Thickness Thickness Allowable Minimum


Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of of Weight
Dimension Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath (approx)
mm 40°C at 70°C m
mm2 No. / mm mm mm kg / km
A M - km
1 PD-VV 1 1/1.13 0.8 1.0 5.4 16 0.0141 35 100/C
1 PD-VV 1 7/0.40 0.8 1.0 5.6 16 0.0135 35 100/C
1.5 PD-VV 1.5 1/1.38 0.8 1.0 5.8 21 0.0123 41 100/C
1.5 PD-VV 1.5 7/0.50 0.8 1.0 6.0 21 0.0116 41 100/C
2.5 PD-VV 2.5 1/1.78 0.8 1.2 6.6 29 0.0102 60 100/C
2.5 PD-VV 2.5 7/0.67 0.8 1.2 7.0 29 0.0093 60 100/C
4 PD-VV 4 1/2.25 0.9 1.2 7.4 39 0.0094 80 100/C
4 PD-VV 4 7/0.85 0.9 1.2 7.8 39 0.0085 80 100/C
6 PD-VV 6 7/1.04 0.9 1.4 8.8 51 0.0073 120 100/C
10 PD-VV 10 7/1.35 1.1 1.4 10.5 70 0.0069 170 100/C
16 PD-VV 16 7/1.70 1.1 1.5 11.5 96 0.0057 250 100/C
25 PD-VV 25 7/2.14 1.3 1.5 13.5 127 0.0054 360 500/R
35 PD-VV 35 19/1.53 1.3 1.6 15.0 157 0.0047 407 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 11
PHELPS DODGE CONDUCTOR TYPE PD-VVF
750 V 70oC PVC INSULATED AND SHEATHED, FLAT TYPE, TWO CORE
Application :
For fixed installation in wet or dry
location. The cable is suitable for
surface wiring or concealed wiring
in wooden partition.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts. Conductor

Reference Standard :
PVC insulation
TIS 11-2531 TABLE 5

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 35 mm
PVC sheath
Insulation : Heat resistance polyvinyl
chloride (Gray and Black colour)

Sheath : Heat resistance polyvinyl


chloride (White colour)

Allowable Minimum
Nominal Number & Thickness Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of of Weight
Diameter Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath (approx)
mm 40°C at 70°C m
mm2 No. / mm mm mm kg / km
A M - km
2X1 PD-VVF 1 1/1.13 0.8 1.4 6.4 x 9.4 13 0.0141 75 100/C
2x1 PD-VVF 1 7/0.40 0.8 1.4 6.6 x 9.8 13 0.0135 75 100/C
2 x 1.5 PD-VVF 1.5 1/1.38 0.8 1.4 6.6 x 10.0 17 0.0123 90 100/C
2 x 1.5 PD-VVF 1.5 7/0.50 0.8 1.4 7.0 x 10.5 17 0.0116 90 100/C
2 x 2.5 PD-VVF 2.5 1/1.78 0.8 1.4 7.2 x 11.0 23 0.0102 110 100/C
2 x 2.5 PD-VVF 2.5 7/0.67 0.8 1.4 7.4 x 11.5 23 0.0093 110 100/C
2 x 4 PD-VVF 4 1/2.25 0.9 1.4 7.8 x 12.5 30 0.0094 160 100/C
2 x 4 PD-VVF 4 7/0.85 0.9 1.4 8.2 x 13.0 30 0.0085 160 100/C
2 x 6 PD-VVF 6 7/1.04 0.9 1.4 8.8 x 14.5 40 0.0073 220 100/C
2 x 10 PD-VVF 10 7/1.35 1.1 1.5 10.5 x 17.0 55 0.0069 340 100/C
2 x 16 PD-VVF 16 7/1.70 1.1 1.5 11.5 x 19.5 74 0.0057 480 500/R
2 x 25 PD-VVF 25 7/2.14 1.3 1.6 13.5 x 23.5 97 0.0054 720 500/R
2 x 35 PD-VVF 35 19/1.53 1.3 1.7 15.0 x 26.5 120 0.0047 940 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
12 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C)
750 V 70oC PVC INSULATED AND SHEATHED, SINGLE CORE
Application :
For installation exposed, or in
raceway, wet or dry location, or
direct burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not Conductor
exceed 750 volts.

Reference Standard :
TIS 11-2531 TABLE 6
PVC insulation

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 500 mm

Insulation : Heat resistance polyvinyl PVC sheath


chloride (Black colour)

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Allowable Minimum
Thickness Thickness Cable
Nominal Number & Overall Ampacities Insulation Standard
PHELPS DODGE of of Weight
Aectional Area Diameter of wire Diameter Free Air Resistance Packing
TYPE LETTER Insulation Sheath (approx)
mm2 No. / mm mm 40°C at 70°C m
mm mm kg / km
A M - km
1 PD-NYY 1 1/1.13 1.5 1.8 8.6 16 0.0207 80 100/C
1 PD-NYY 1 7/0.40 1.5 1.8 8.8 16 0.0200 80 100/C
1.5 PD-NYY 1.5 1/1.38 1.5 1.8 9.0 21 0.0184 90 100/C
1.5 PD-NYY 1.5 7/0.50 1.5 1.8 9.2 21 0.0175 90 100/C
2.5 PD-NYY 2.5 1/1.78 1.5 1.8 9.4 29 0.0157 100 100/C
2.5 PD-NYY 2.5 7/0.67 1.5 1.8 9.8 29 0.0146 100 100/C
4 PD-NYY 4 1/2.25 1.5 1.8 10.0 39 0.0135 130 100/C
4 PD-NYY 4 7/0.85 1.5 1.8 10.5 39 0.0124 130 100/C
6 PD-NYY 6 7/1.04 1.5 1.8 11.0 51 0.0107 160 100/C
10 PD-NYY 10 7/1.35 1.5 1.8 12.0 70 0.0088 210 500/R
16 PD-NYY 16 7/1.70 1.5 1.8 13.0 96 0.0074 280 500/R
25 PD-NYY 25 7/2.14 1.5 1.8 14.5 127 0.0061 390 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 13
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C)
750 V 70oC PVC INSULATED AND SHEATHED, SINGLE CORE
Application :
For installation exposed, or in
raceway, wet or dry location, or
direct burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not Conductor
exceed 750 volts.

Reference Standard :
TIS 11-2531 TABLE 6 PVC insulation

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 500 mm

Insulation : Heat resistance polyvinyl PVC sheath


chloride (Black colour)

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Allowable Minimum
Nominal Number & Thickness Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of of Weight
Diameter Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath (approx)
mm 40°C at 70°C m
mm2 No. / mm mm mm kg / km
A M - km
35 PD-NYY 35 19/1.53 1.5 1.8 16.0 157 0.0053 500 500/R
50 PD-NYY 50 19/1.78 1.5 1.8 17.0 191 0.0046 660 500/R
70 PD-NYY 70 19/2.14 1.5 1.8 19.0 244 0.0039 850 500/R
95 PD-NYY 95 19/2.52 1.7 1.8 21.5 297 0.0038 1,150 500/R
120 PD-NYY 120 37/2.03 1.7 1.8 23.0 345 0.0034 1,400 500/R
150 PD-NYY 150 37/2.25 1.9 2.0 26.0 397 0.0034 1,720 500/R
185 PD-NYY 185 37/2.52 2.1 2.0 28.0 453 0.0034 2,130 500/R
240 PD-NYY 240 61/2.25 2.3 2.2 31.5 535 0.0033 2,760 500/R
300 PD-NYY 300 61/2.52 2.5 2.2 35.0 617 0.0032 3,400 500/R
400 PD-NYY 400 61/2.85 2.7 2.2 38.5 741 0.0030 4,290 500/R
500 PD-NYY 500 61/3.20 3.1 2.4 43.0 854 0.0031 5,570 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
14 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, TWO CORE
Application :
For installation exposed, or in
raceway, wet or dry location, or
direct burial in ground.

Classification :
Maximum conductor Conductor
o
temperature 70 C Circuit voltage
does not exceed 750 volts.
PVC insulation
Reference Standard :
TIS 11-2531 TABLE 7

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm

Insulation : Heat resistance polyvinyl PVC outer sheath


chloride (Gray and Black colour)
PVC inner sheath
Inner sheath : Heat resistance
polyvinyl chloride (Black colour)

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Allowable Minimum
Nominal Number & Thickness Thickness Thickness Cable
Overall Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of of Inner of Outer Weight
Diameter Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath Sheath (approx)
mm 40°C at 70°C m
mm2 No. / mm mm mm mm kg / km
A M - km
2x1 PD-NYY 1 1/1.13 0.8 0.8 1.8 12.0 13 0.0141 160 500/R
2x1 PD-NYY 1 7/0.40 0.8 0.8 1.8 12.5 13 0.0135 160 500/R
2 x 1.5 PD-NYY 1.5 1/1.38 0.8 0.8 1.8 12.5 17 0.0123 180 500/R
2 x 1.5 PD-NYY 1.5 7/0.50 0.8 0.8 1.8 13.0 17 0.0116 180 500/R
2 x 2.5 PD-NYY 2.5 1/1.78 0.8 0.8 1.8 13.5 23 0.0102 210 500/R
2 x 2.5 PD-NYY 2.5 7/0.67 0.8 0.8 1.8 14.0 23 0.0093 210 500/R
2x4 PD-NYY 4 1/2.25 0.9 0.8 1.8 15.0 30 0.0094 280 500/R
2x4 PD-NYY 4 7/0.85 0.9 0.8 1.8 15.5 30 0.0085 280 500/R
2x6 PD-NYY 6 7/1.04 0.9 0.8 1.8 17.0 40 0.0073 370 500/R
2 x 10 PD-NYY 10 7/1.35 1.1 0.8 1.8 19.5 55 0.0069 530 500/R
2 x 16 PD-NYY 16 7/1.70 1.1 0.8 2.0 22.5 74 0.0057 720 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 15
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, TWO CORE
Application :
For installation exposed, or in
raceway, wet or dry location, or
direct burial in ground.

Classification :
Maximum conductor Conductor
o
temperature 70 C Circuit voltage
does not exceed 750 volts.
PVC insulation
Reference Standard :
TIS 11-2531 TABLE 7

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm

Insulation : Heat resistance polyvinyl PVC outer sheath


chloride (Gray and Black colour)
PVC inner sheath
Inner sheath : Heat resistance
polyvinyl chloride (Black colour)

Sheath : Heat resistance polyvinyl


chloride (Black colour)

.UMBER !LLOWABLE -INIMUM


.OMINAL 4HICKNESS 4HICKNESS 4HICKNESS #ABLE
$IAMETER /VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL OF OF)NNER OF/UTER 7EIGHT
OF7IRE $IAMETER &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA )NSULATION 3HEATH 3HEATH APPROX
.OMM MM —# AT—# M
MM MM MM MM KGKM
! - KM
ÓÊÝÊÓxÊÊÊÊÊÊ* ‡ 99 Óx ÇÉÓ°£{ £°Î £°Ó Ó°ä ÓÇ°ä ™Ç ä°ääx{ £]ä™ä xääÉ,
ÓÊÝÊÎxÊÊÊÊÊÊ* ‡ 99 Îx £™É£°xÎ £°Î £°Ó Ó°ä ә°x £Óä ä°ää{Ç £]ÎÈä xääÉ,
ÓÊÝÊxäÊÊÊÊÊÊ* ‡ 99 xä £™É£°Çn £°x £°Ó Ó°Ó Îΰx £{È ä°ää{È £]nnä xääÉ,
ÓÊÝÊÇäÊÊÊÊÊÊ* ‡ 99 Çä £™ÉÓ°£{ £°x £°x Ó°Ó În°ä £nx ä°ääΙ Ó]{Îä xääÉ,
ÓÊÝʙxÊÊÊÊÊÊ* ‡ 99 ™x £™ÉÓ°xÓ £°Ç £°x Ó°Ó {Ó°x ÓÓ{ ä°ääÎn Î]ÓÓä xääÉ,
ÓÊÝÊ£ÓäÊÊÊÊ* ‡ 99 £Óä ÎÇÉÓ°äÎ £°Ç £°x Ó°{ {È°x ÓÈä ä°ääÎ{ Î]™{ä xääÉ,
ÓÊÝÊ£xäÊÊÊÊ* ‡ 99 £xä ÎÇÉÓ°Óx £°™ £°n Ó°È xÓ°ä ә™ ä°ääÎ{ {]n{ä ÎääÉ,
ÓÊÝÊ£nxÊÊÊÊ* ‡ 99 £nx ÎÇÉÓ°xÓ Ó°£ £°n Ó°n xÇ°ä Î{£ ä°ääÎ{ x]™Çä ÎääÉ,
ÓÊÝÊÓ{äÊÊÊÊ* ‡ 99 Ó{ä È£ÉÓ°Óx Ó°Î Ó°ä ΰä È{°ä {ä£ ä°ääÎÎ Ç]Çää ÓxäÉ,
ÓÊÝÊÎääÊÊÊÊ* ‡ 99 Îää È£ÉÓ°xÓ Ó°x Ó°ä Î°Ó Çä°x {È£ ä°ääÎÓ ™]{xä ÓääÉ,

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
16 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE CORE
Application :
For installation exposed, or in
raceway, wet or dry location, or
direct burial in ground.

Classification :
Maximum conductor
o
temperature 70 C Circuit voltage Conductor
does not exceed 750 volts.
PVC insulation
Reference Standard :
TIS 11-2531 TABLE 7

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm
PVC outer sheath
Insulation : Heat resistance
polyvinyl chloride (Gray, Black and PVC inner sheath
Red colour)

Inner sheath : Heat resistance


polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

!LLOWABLE -INIMUM
.OMINAL .UMBER 4HICKNESS 4HICKNESS 4HICKNESS #ABLE
/VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL $IAMETER OF OF)NNER OF/UTER 7EIGHT
$IAMETER &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA OF7IRE )NSULATION 3HEATH 3HEATH APPROX
MM —# AT—# M
MM .OMM MM MM MM KGKM
! - KM
ÎÊÝÊ£ÊÊÊÊÊÊ* ‡ 99 £ £É£°£Î ä°n ä°n £°n £Ó°x ££°x ä°ä£{£ £nä xääÉ,
ÎÊÝÊ£ÊÊÊÊÊÊ* ‡ 99 £ ÇÉä°{ä ä°n ä°n £°n £Î°ä ££°x ä°ä£Îx £nä xääÉ,
ÎÊÝÊ£°xÊÊÊ* ‡ 99 £°x £É£°În ä°n ä°n £°n £Î°ä £x ä°ä£ÓÎ Óää xääÉ,
ÎÊÝÊ£°xÊÊÊ* ‡ 99 £°x ÇÉä°xä ä°n ä°n £°n £Î°x £x ä°ä££È Óää xääÉ,
ÎÊÝÊÓ°xÊÊÊ* ‡ 99 Ó°x £É£°Çn ä°n ä°n £°n £{°ä Ó£ ä°ä£äÓ Óxä xääÉ,
ÎÊÝÊÓ°xÊÊÊ* ‡ 99 Ó°x ÇÉä°ÈÇ ä°n ä°n £°n £x°ä Ó£ ä°ää™Î Óxä xääÉ,
ÎÊÝÊ{ÊÊÊÊÊÊ* ‡ 99 { £ÉÓ°Óx 䰙 ä°n £°n £x°x Ón ä°ää™{ ÎÎä xääÉ,
ÎÊÝÊ{ÊÊÊÊÊ* ‡ 99 { ÇÉä°nx 䰙 ä°n £°n £È°x Ón ä°äänx ÎÎä xääÉ,
ÎÊÝÊÈÊÊÊÊÊ* ‡ 99 È ÇÉ£°ä{ 䰙 ä°n £°n £n°ä ÎÈ ä°ääÇÎ {{ä xääÉ,
ÎÊÝÊ£äÊÊÊ* ‡ 99 £ä ÇÉ£°Îx £°£ ä°n £°n Óä°x xä ä°ääș È{ä xääÉ,
ÎÊÝÊ£ÈÊÊÊ* ‡ 99 £È ÇÉ£°Çä £°£ £°Ó Ó°ä Ó{°x ÈÈ ä°ääxÇ ™Îä xääÉ,
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 17
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE CORE
Application :
For installation exposed, or in
raceway, wet or dry location, or
direct burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not Conductor
exceed 750 volts.
PVC insulation
Reference Standard :
TIS 11-2531 TABLE 7

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm
PVC outer sheath
Insulation : Heat resistance
polyvinyl chloride (Gray, Black and PVC inner sheath
Red colour)

Inner sheath : Heat resistance


polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

!LLOWABLE -INIMUM
.OMINAL .UMBER 4HICKNESS 4HICKNESS 4HICKNESS #ABLE
/VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL $IAMETER OF OF)NNER OF/UTER 7EIGHT
$IAMETER &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA OF7IRE )NSULATION 3HEATH 3HEATH APPROX
MM —# AT—# M
MM .OMM MM MM MM KGKM
! - KM
ÎÊÝÊÓxÊÊÊÊÊ* ‡ 99 Óx ÇÉÓ°£{ £°Î £°Ó Ó°ä Ón°x n{ ä°ääx{ £]ÎÈä xääÉ,
ÎÊÝÊÎxÊÊÊÊÊ* ‡ 99 Îx £™É£°xÎ £°Î £°Ó Ó°ä Σ°x £ä{ ä°ää{Ç £]ÇÎä xääÉ,
ÎÊÝÊxäÊÊÊÊÊ* ‡ 99 xä £™É£°Çn £°x £°x Ó°Ó ÎÈ°ä £Óx ä°ää{È Ó]{{ä xääÉ,
ÎÊÝÊÇäÊÊÊÊÊ* ‡ 99 Çä £™ÉÓ°£{ £°x £°x Ó°Ó {ä°x £Èä ä°ääΙ Î]££ä xääÉ,
ÎÊÝʙxÊÊÊÊÊ* ‡ 99 ™x £™ÉÓ°xÓ £°Ç £°x Ó°{ {È°ä £™{ ä°ääÎn {]£nä xääÉ,
ÎÊÝÊ£ÓäÊÊÊ* ‡ 99 £Óä ÎÇÉÓ°äÎ £°Ç £°n Ó°È xä°x ÓÓx ä°ääÎ{ x]£™ä ÎääÉ,
ÎÊÝÊ£xäÊÊÊ* ‡ 99 £xä ÎÇÉÓ°Óx £°™ £°n Ó°n xÈ°ä ÓxÈ ä°ääÎ{ È]Îää ÎääÉ,
ÎÊÝÊ£nxÊÊÊ* ‡ 99 £nx ÎÇÉÓ°xÓ Ó°£ Ó°ä ΰä È£°x  ä°ääÎ{ Ç]n{ä ÎääÉ,
ÎÊÝÊÓ{äÊÊÊ* ‡ 99 Ó{ä È£ÉÓ°Óx Ó°Î Ó°ä Î°Ó È™°ä Îx£ ä°ääÎÎ £ä]äÈä ÓääÉ,
ÎÊÝÊÎääÊÊÊ* ‡ 99 Îää È£ÉÓ°xÓ Ó°x Ó°Ó Î°{ ÇÈ°ä {ä{ ä°ääÎÓ £Ó]{xä £xäÉ,

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
18 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, FOUR CORE
Application :
For installation exposed, or in
raceway, wet or dry location, or
direct burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not Conductor
exceed 750 volts.
PVC insulation
Reference Standard :
TIS 11-2531 TABLE 7

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm

Insulation : Heat resistance polyvinyl


chloride (Gray, Black Red and Blue PVC outer sheath
colour)
PVC inner sheath
Inner sheath : Heat resistance
polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

!LLOWABLE -INIMUM
.OMINAL .UMBER 4HICKNESS 4HICKNESS 4HICKNESS #ABLE
/VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL $IAMETER OF OF)NNER OF/UTER 7EIGHT
$IAMETER &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA OF7IRE )NSULATION 3HEATH 3HEATH APPROX
MM —# AT—# M
MM .OMM MM MM MM KGKM
! - KM
{ÊÝÊ£ÊÊÊÊÊ* ‡ 99 £ £É£°£Î ä°n ä°n £°n £Î°x ££°x ä°ä£{£ Óää xääÉ,
{ÊÝÊ£ÊÊÊÊÊ* ‡ 99 £ ÇÉä°{ä ä°n ä°n £°n £{°ä ££°x ä°ä£Îx Óää xääÉ,
{ÊÝÊ£°xÊÊÊ* ‡ 99 £°x £É£°În ä°n ä°n £°n £{°ä £x ä°ä£ÓÎ ÓÎä xääÉ,
{ÊÝÊ£°xÊÊÊ* ‡ 99 £°x ÇÉä°xä ä°n ä°n £°n £{°x £x ä°ä££È ÓÎä xääÉ,
{ÊÝÊÓ°xÊÊÊ* ‡ 99 Ó°x £É£°Çn ä°n ä°n £°n £x°ä Ó£ ä°ä£äÓ Ó™ä xääÉ,
{ÊÝÊÓ°xÊÊÊ* ‡ 99 Ó°x ÇÉä°ÈÇ ä°n ä°n £°n £È°ä Ó£ ä°ää™Î әä xääÉ,
{ÊÝÊ{ÊÊÊÊÊ* ‡ 99 { £ÉÓ°Óx 䰙 ä°n £°n £Ç°ä Ón ä°ää™{ Ιä xääÉ,
{ÊÝÊ{ÊÊÊÊÊ* ‡ 99 { ÇÉä°nx 䰙 ä°n £°n £Ç°x Ón ä°äänx Ιä xääÉ,
{ÊÝÊÈÊÊÊÊÊ* ‡ 99 È ÇÉ£°ä{ 䰙 ä°n £°n £™°ä ÎÈ ä°ääÇÎ xÎä xääÉ,
{ÊÝÊ£äÊÊÊ* ‡ 99 £ä ÇÉ£°Îx £°£ ä°n Ó°ä Óΰä xä ä°ääș n£ä xääÉ,
{ÊÝÊ£ÈÊÊÊ* ‡ 99 £È ÇÉ£°Çä £°£ £°Ó Ó°ä ÓÈ°x ÈÈ ä°ääxÇ £]£Èä xääÉ,
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 19
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, FOUR CORE
Application :
For installation exposed, or in
raceway, wet or dry location, or
direct burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not exceed Conductor
750 volts.

Reference Standard : PVC insulation


TIS 11-2531 TABLE 7

Construction :
Conducor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm
PVC outer sheath
Insulation : Heat resistance polyvinyl PVC inner sheath
chloride (Gray, Black, Red and Blue
colour)

Inner sheath : Heat resistance


polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

!LLOWABLE -INIMUM
.OMINAL .UMBER 4HICKNESS 4HICKNESS 4HICKNESS #ABLE
/VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL $IAMETER OF OF)NNER OF/UTER 7EIGHT
$IAMETER &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA OF7IRE )NSULATION 3HEATH 3HEATH APPROX
MM —# AT—# M
MM .OMM MM MM MM KGKM
! - KM
{ÊÝÊÓxÊÊÊÊ* ‡ 99 Óx ÇÉÓ°£{ £°Î £°Ó Ó°ä Σ°ä n{ ä°ääx{ £]Çää xääÉ,
{ÊÝÊÎxÊÊÊÊ* ‡ 99 Îx £™É£°xÎ £°Î £°x Ó°Ó Îx°ä £{ä ä°ää{Ç Ó]Ó{ä xääÉ,
{ÊÝÊxäÊÊÊÊ* ‡ 99 xä £™É£°Çn £°x £°x Ó°Ó Î™°x £Óx ä°ää{È Î]äÇä xääÉ,
{ÊÝÊÇäÊÊÊÊ* ‡ 99 Çä £™ÉÓ°£{ £°x £°x Ó°{ {{°x £Èä ä°ääΙ Î]™Çä xääÉ,
{ÊÝʙxÊÊÊÊ* ‡ 99 ™x £™ÉÓ°xÓ £°Ç £°n Ó°È x£°x £™{ ä°ääÎn x]{£ä ÎääÉ,
{ÊÝÊ£ÓäÊÊ* ‡ 99 £Óä ÎÇÉÓ°äÎ £°Ç £°n Ó°n xÈ°ä ÓÓx ä°ääÎ{ È]È{ä ÎääÉ,
{ÊÝÊ£xäÊÊ* ‡ 99 £xä ÎÇÉÓ°Óx £°™ Ó°ä ΰä ÈÓ°ä ÓxÈ ä°ääÎ{ n]£Îä ÎääÉ,
{ÊÝÊ£nxÊÊ* ‡ 99 £nx ÎÇÉÓ°xÓ Ó°£ Ó°ä Î°Ó Èn°ä  ä°ääÎ{ £ä]äxä ÓääÉ,
{ÊÝÊÓ{äÊÊ* ‡ 99 Ó{ä È£ÉÓ°Óx Ó°Î Ó°Ó Î°{ ÇÈ°x Îx£ ä°ääÎÎ £Ó]™Èä ÓääÉ,
{ÊÝÊÎääÊÊ* ‡ 99 Îää È£ÉÓ°xÓ Ó°x Ó°Ó Î°n nx°ä {ä{ ä°ääÎÓ £È]ä{ä £xäÉ,
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
20 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-NYY-N (MEA TYPE C-N)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE PHASE WITH NEUTRAL
Application :
For installation exposed, or in
raceway, wet or dry location, or
direct burial in ground.

Classification :
Maximum conductor
o
temperature 70 C Circuit voltage
does not exceed 750 volts. Phase Conductor

Reference Standard :
TIS 11-2531 TABLE 8
PVC insulation

Construction :
Conducor : Annealed copper,
concentric or stranded
2 2
Sizes 6 mm up to 300 mm (Phase)
2 2
Sizes 4 mm up to 150 mm (Neutral)

Insulation : Heat resistance polyvinyl


chloride (Black, Red, and Blue) PVC outer sheath
Phase, (Gray colour) Neutral.

Inner sheath : Heat resistance PVC inner sheath


polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

0HASECORE .EUTRALCORE
!LLOWABLE -INIMUM
.OMINAL .UMBER 4HICKNESS .OMINAL .UMBER 4HICKNESS 4HICKNESS 4HICKNESS /VERALL #ABLE
!MPACITIES )NSULATION
0(%,03$/$'% 3ECTIONAL $IAMETER OF 3ECTIONAL $IAMETER OF OF)NNER OF/UTER )NSULATION 7EIGHT 3TANDARD
&REE!IR 2ESISTANCE
490%,%44%2 !REA OF7IRE )NSULATION !REA OF7IRE )NSULATION 3HEATH 3HEATH $IAMETER-AX APPROX 0ACKING
—# AT—# M
MM 
.OMM MM MM 
.OMM MM MM MM MM KGKM
! - KM
ÎÊÝÊÈÉ{ÊÊÊÊÊÊÊÊÊ* ‡ 99‡ È ÇÉ£°ä{ 䰙 { ÇÉä°nx 䰙 ä°n £°n £™°ä ÎÈ ä°ääÇÎ xÓä xääÉ,
ÎÊÝÊ£äÉÈÊÊÊÊÊÊÊ* ‡ 99‡ £ä ÇÉ£°Îx £°£ È ÇÉ£°ä{ 䰙 ä°n Ó°ä Óΰä xä ä°ääș ÇÈä xääÉ,
ÎÊÝÊ£ÈÉ£äÊÊÊÊÊ* ‡ 99‡ £È ÇÉ£°Çä £°£ £ä ÇÉ£°Îx £°£ £°Ó Ó°ä ÓÈ°x ÈÈ ä°ääxÇ £]£ää xääÉ,
ÎÊÝÊÓxÉ£ÈÊÊÊÊÊ* ‡ 99‡ Óx ÇÉÓ°£{ £°Î £È ÇÉ£°Çä £°£ £°Ó Ó°ä Σ°ä n{ ä°ääx{ £]xÇä xääÉ,
ÎÊÝÊÎxÉ£ÈÊÊÊÊÊ* ‡ 99‡ Îx £™É£°xÎ £°Î £È ÇÉ£°Çä £°£ £°x Ó°Ó Îx°ä £ä{ ä°ää{Ç Ó]äää xääÉ,
ÎÊÝÊxäÉÓxÊÊÊÊÊ* ‡ 99‡ xä £™É£°Çn £°x Óx ÇÉÓ°£{ £°Î £°x Ó°Ó Î™°x £Óx ä°ää{È Ó]ÇÇä xääÉ,
ÎÊÝÊÇäÉÎxÊÊÊÊÊ* ‡ 99‡ Çä £™ÉÓ°£{ £°x Îx £™É£°xÎ £°Î £°x Ó°{ {{°x £Èä ä°ääΙ Î]Èää xääÉ,
ÎÊÝʙxÉxäÊÊÊÊÊ* ‡ 99‡ ™x £™ÉÓ°xÓ £°Ç xä £™É£°Çn £°x £°n Ó°È x£°x £™{ ä°ääÎn {]n™ä xääÉ,
ÎÊÝÊ£ÓäÉÇäÊÊÊ* ‡ 99‡ £Óä ÎÇÉÓ°äÎ £°Ç Çä £™ÉÓ°£{ £°x £°n Ó°n xÈ°ä ÓÓx ä°ääÎ{ È]äxä ÎääÉ,
ÎÊÝÊ£xäÉÇäÊÊÊ* ‡ 99‡ £xä ÎÇÉÓ°Óx £°™ Çä £™ÉÓ°£{ £°x Ó°ä ΰä ÈÓ°ä ÓxÈ ä°ääÎ{ Ç]Óää ÎääÉ,
ÎÊÝÊ£nxəxÊÊÊ* ‡ 99‡ £nx ÎÇÉÓ°xÓ Ó°£ ™x £™ÉÓ°xÓ £°Ç Ó°ä Î°Ó Èn°ä  ä°ääÎ{ ™]äää ÓääÉ,
ÎÊÝÊÓ{äÉ£ÓäÊ* ‡ 99‡ Ó{ä È£ÉÓ°Óx Ó°Î £Óä ÎÇÉÓ°äÎ £°Ç Ó°Ó Î°{ ÇÈ°x Îx£ ä°ääÎÎ ££]xÎä ÓääÉ,
ÎÊÝÊÎääÉ£xäÊ* ‡ 99‡ Îää È£ÉÓ°xÓ Ó°x £xä ÎÇÉÓ°Óx £°™ Ó°Ó Î°n n{°x {ä{ ä°ääÎÓ £{]Ó™ä £xäÉ,

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 21
PHELPS DODGE CONDUCTOR TYPE PD-VCT
750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE SINGLE CORE
Application :
For mobile-electrical equipment
used in mines, factories, farm or
household appliances. This cable
is particularly suitable for use in
chemical factories or in place where
cables come in contact with oils.

Classification : Conductor
Maximum conductor temperature
o
70 C Circuit voltage does not exceed PVC insulation
750 volts.

Reference Standard :
TIS 11-2531 TABLE 9

Construction :
Conductor : Annealed copper,
bunch stranded PVC sheath
2 2
Sizes 0.5 mm up to 95 mm

Insulation : Heat resistance


polyvinyl chloride (Black colour)

sheath : Heat resistance polyvinyl


chloride (Black colour)

!LLOWABLE -INIMUM
.OMINAL .UMBER 4HICKNESS 4HICKNESS #ABLE
/VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL $IAMETER OF OF 7EIGHT
$IMENSION &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA OF7IRE )NSULATION 3HEATH APPROX
MM —# AT—# M
MM 
.OMM MM MM KGKM
! - KM
ä°xÊÊÊÊÊ* ‡6
/ ä°x £ÈÉä°Ó£ ä°n £°ä x°{ ££ ä°ä£Èä ÓÇ xääÉ,
ä°ÇxÊÊÊ* ‡6
/ ä°Çx Ó{Éä°Ó£ ä°n £°ä x°È £{ ä°ä£{ä Σ xääÉ,
£ÊÊÊÊÊÊÊÊ* ‡6
/ £ ÎÓÉä°Ó£ ä°n £°Ó È°Ó £È ä°ä£ÓÇ Î™ xääÉ,
£°xÊÊÊÊÊ* ‡6
/ £°x ÎäÉä°ÓÈ ä°n £°Ó È°È Ó£ ä°ä£££ {È xääÉ,
Ó°xÊÊÊÊÊ* ‡6
/ Ó°x xäÉä°ÓÈ ä°n £°Ó Ç°{ ә ä°ää™Ó x™ xääÉ,
{ÊÊÊÊÊÊÊÊ* ‡6
/ { xÈÉä°Î£ 䰙 £°{ n°È Ι ä°ään{ nÇ xääÉ,
ÈÊÊÊÊÊÊÊÊ* ‡6
/ È n{Éä°Î£ 䰙 £°{ ™°{ x£ ä°ääÇ£ ££{ xääÉ,
£äÊÊÊÊÊÊ* ‡6
/ £ä näÉä°{£ £°£ £°n £Ó°ä Çä ä°ääÈn £™ä xääÉ,
£ÈÊÊÊÊÊÊ* ‡6
/ £È £ÓÈÉä°{£ £°£ £°n £Î°x ™È ä°ääxä ÓxÈ xääÉ,
ÓxÊÊÊÊÊÊ* ‡6
/ Óx £™ÈÉä°{£ £°Î Ó°Ó £È°ä £ÓÇ ä°ää{n Ι£ xääÉ,
ÎxÊÊÊÊÊÊ* ‡6
/ Îx ÓÇÈÉä°{£ £°Î Ó°Ó £Ç°x £xÇ ä°ää{£ xä{ xääÉ,
xäÊÊÊÊÊÊ* ‡6
/ xä ΙÈÉä°{£ £°x Ó°È Ó£°ä £™£ ä°ää{ä ÇÇä xääÉ,
ÇäÊÊÊÊÊÊ* ‡6
/ Çä ÎÈäÉä°x£ £°x Ó°È Óΰä Ó{{ ä°ääÎ{ ™Ç{ xääÉ,
™xÊÊÊÊÊÊ* ‡6
/ ™x {ÇxÉä°x£ £°Ç ΰä ÓÈ°x  ä°ääÎ{ £]Ó{Ó xääÉ,
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
22 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VCT
750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE TWO CORE
Application :
For mobile-electrical equipment
used in mines, factories, farm or
household appliances. This cable
is particularly suitable for use in
chemical factories or in places where
cables come in contact with oils.

Classification :
Maximum conductor temperature Conductor
o
70 C Circuit voltage does not exceed
750 volts.
PVC insulation
Reference Standard :
TIS 11-2531 TABLE 9

Construction :
Conductor : Annealed copper,
bunch stranded
2 2
Sizes 0.5 mm up to 35 mm
PVC sheath
Insulation : Heat resistance polyvinyl
chloride (Gray and Black colour)

Sheath : Heat resistance


polyvinyl chloride (Black colour)

!LLOWABLE -INIMUM
.OMINAL -IN.UMBER 4HICKNESS 4HICKNESS #ABLE
/VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL -AX$IAMETER OF OF 7EIGHT
$IAMETER &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA OF7IRE )NSULATION 3HEATH APPROX
MM —# AT—# M
MM .OMM MM MM KGKM
! - KM
ÓÊÝÊä°xÊÊÊÊ* ‡6
/ ä°x £ÈÉä°Ó£ ä°n £°Ó n°n n ä°ä£Èä xÈ xääÉ,
ÓÊÝÊä°ÇxÊÊ* ‡6
/ ä°Çx Ó{Éä°Ó£ ä°n £°Ó ™°Ó ££ ä°ä£{ä Èx xääÉ,
ÓÊÝÊ£ÊÊÊÊÊÊÊ* ‡6
/ £ ÎÓÉä°Ó£ ä°n £°Ó ™°È £Î ä°ä£ÓÇ ÇÓ xääÉ,
ÓÊÝÊ£°xÊÊÊÊÊ* ‡6
/ £°x ÎäÉä°ÓÈ ä°n £°{ ££°ä £Ç ä°ä£££ ™{ xääÉ,
ÓÊÝÊÓ°xÊÊÊÊÊ* ‡6
/ Ó°x xäÉä°ÓÈ ä°n £°{ £Ó°x ÓÎ ä°ää™Ó £ÎÎ xääÉ,
ÓÊÝÊ{ÊÊÊÊÊÊÊÊ* ‡6
/ { xÈÉä°Î£ 䰙 £°È £{°x Îä ä°ään{ £™™ xääÉ,
ÓÊÝÊÈÊÊÊÊÊÊÊÊ* ‡6
/ È n{Éä°Î£ 䰙 £°È £È°ä {ä ä°ääÇ£ ÓxÈ xääÉ,
ÓÊÝÊ£äÊÊÊÊÊÊ* ‡6
/ £ä näÉä°{£ £°£ £°n Óä°ä xx ä°ääÈn {ä£ xääÉ,
ÓÊÝ£ÈÊÊÊÊÊÊÊ* ‡6
/ £È £ÓÈÉä°{£ £°£ Ó°Ó Óΰä Ç{ ä°ääxä xn£ xääÉ,
ÓÊÝÊÓxÊÊÊÊÊÊ* ‡6
/ Óx £™ÈÉä°{£ £°Î Ó°{ ÓÇ°x ™Ç ä°ää{n nÈÓ xääÉ,
ÓÊÝÊÎxÊÊÊÊÊÊ* ‡6
/ Îx ÓÇÈÉä°{£ £°Î Ó°È Î£°ä £Óä ä°ää{£ £]£În xääÉ,
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 23
PHELPS DODGE CONDUCTOR TYPE PD-VCT
750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE THREE CORE
Application :
For mobile-electrical equipment
used in mines, factories, farm or
household appliances. This cable
is particularly suitable for use in
chemical factories or in places where
cables come in contact with oils.
Conductor
Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not exceed
750 volts.

Reference Standard : PVC sheath


TIS 11-2531 TABLE 9

Construction :
Conductor : Annealed copper,
bunch stranded
2 2
Sizes 0.5 mm up to 35 mm
PVC insulation
Insulation : Heat resistance polyvinyl
chloride (Gray, Black and Red
colour)

Sheath : Heat resistance


polyvinyl chloride (Black colour)

-IN.UMBER !LLOWABLE -INIMUM


.OMINAL 4HICKNESS 4HICKNESS #ABLE
-AX$IAMETER /VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL OF OF 7EIGHT
OF7IRE $IMENSION &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA )NSULATION 3HEATH APPROX
.OMM MM —# AT—# M
MM 
MM MM KGKM
! - KM
ÎÊÝÊä°xÊÊÊÊÊÊ* ‡6
/ ä°x £ÈÉä°Ó£ ä°n £°Ó ™°Ó È°x ä°ä£Èä ș xääÉ,
ÎÊÝÊä°ÇxÊÊÊÊ* ‡6
/ ä°Çx Ó{Éä°Ó£ ä°n £°Ó ™°È ™°ä ä°ä£{ä n£ xääÉ,
ÎÊÝÊ£ÊÊÊÊÊÊÊÊÊ* ‡6
/ £ ÎÓÉä°Ó£ ä°n £°{ £ä°x ££°x ä°ä£ÓÇ £ää xääÉ,
ÎÊÝÊ£°xÊÊÊÊÊÊ* ‡6
/ £°x ÎäÉä°ÓÈ ä°n £°{ ££°x £x ä°ä£££ ££™ xääÉ,
ÎÊÝÊÓ°xÊÊÊÊÊÊ* ‡6
/ Ó°x xäÉä°ÓÈ ä°n £°{ £Î°ä Ó£ ä°ää™Ó £Çä xääÉ,
ÎÊÝÊ{ÊÊÊÊÊÊÊÊÊ* ‡6
/ { xÈÉä°Î£ 䰙 £°È £x°x Ón ä°ään{ Ó{{ xääÉ,
ÎÊÝÊÈÊÊÊÊÊÊÊÊÊ* ‡6
/ È n{Éä°Î£ 䰙 £°n £Ç°x ÎÈ ä°ääÇ£ Î{Ç xääÉ,
ÎÊÝÊ£äÊÊÊÊÊÊÊÊ* ‡6
/ £ä näÉä°{£ £°£ Ó°ä Ó£°x xä ä°ääÈn x{n xääÉ,
ÎÊÝÊ£ÈÊÊÊÊÊÊÊÊ* ‡6
/ £È £ÓÈÉä°{£ £°£ Ó°{ Óx°ä ÈÈ ä°ääxä Ǚ£ xääÉ,
ÎÊÝÊÓxÊÊÊÊÊÊÊÊ* ‡6
/ Óx £™ÈÉä°{£ £°Î Ó°È Îä°ä n{ ä°ää{n £]£x£ xääÉ,
ÎÊÝÊÎxÊÊÊÊÊÊÊÊ* ‡6
/ Îx ÓÇÈÉä°{£ £°Î Ó°n Îΰx £ä{ ä°ää{£ £]x{ä xääÉ,

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
24 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VCT
750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE FOUR CORE
Application :
For mobile-electrical equipment
used in mines, factories, farm or
household appliances. This cable
is particularly suitable for use in
chemical factories or in places where
cables come in contact with oils.

Classification : Conductor
Maximum conductor temperature
o
70 C Circuit voltage does not exceed
750 volts.
PVC insulation
Reference Standard :
TIS 11-2531 TABLE 9

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 0.5 mm up to 35 mm

Insulation : Heat resistance polyvinyl PVC sheath


chloride (Gray, Black, Red and Blue
colour)

Sheath : Heat resistance


polyvinyl chloride (Black colour)

-IN.UMBER !LLOWABLE -INIMUM


.OMINAL 4HICKNESS 4HICKNESS #ABLE
-AX$IAMETER /VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL OF OF 7EIGHT
OF7IRE $IMENSION &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA )NSULATION 3HEATH APPROX
 .OMM MM —# AT—# M
MM MM MM KGKM
! - KM
{ÊÝÊä°xÊÊÊÊÊÊ* ‡6
/ ä°x £ÈÉä°Ó£ ä°n £°{ £ä°x È°x ä°ä£Èä ™Ó xääÉ,
{ÊÝÊä°ÇxÊÊÊÊ* ‡6
/ ä°Çx Ó{Éä°Ó£ ä°n £°{ ££°ä ™ ä°ä£{ä £äÇ xääÉ,
{ÊÝÊ£ÊÊÊÊÊÊÊÊÊ* ‡6
/ £ ÎÓÉä°Ó£ ä°Èn £°È £Ó°ä ££°x ä°ä£ÓÇ £Îä xääÉ,
{ÊÝÊ£°xÊÊÊÊÊÊ* ‡6
/ £°x ÎäÉä°ÓÈ ä°n £°È £Ó°x £x ä°ä£££ £xÈ xääÉ,
{ÊÝÊÓ°xÊÊÊÊÊÊÊ* ‡6
/ Ó°x xäÉä°ÓÈ ä°n £°È £x°ä Ó£ ä°ää™Ó Ó£™ xääÉ,
{ÊÝÊ{ÊÊÊÊÊÊÊÊÊÊ* ‡6
/ { xÈÉä°Î£ 䰙 £°n £Ç°ä Ón ä°ään{ Î£È xääÉ,
{ÊÝÊÈÊÊÊÊÊÊÊÊÊÊ* ‡6
/ È n{Éä°Î£ 䰙 Ó°ä £™°x ÎÈ ä°ääÇ£ {{È xääÉ,
{ÊÝÊ£äÊÊÊÊÊÊÊÊ* ‡6
/ £ä näÉä°{£ £°£ Ó°Ó Ó{°ä xä ä°ääÈn ÇäÎ xääÉ,
{ÊÝÊ£ÈÊÊÊÊÊÊÊÊ* ‡6
/ £È £ÓÈÉä°{£ £°£ Ó°È Ón°ä ÈÈ ä°ääxä £]ä£x xääÉ,
{ÊÝÊÓxÊÊÊÊÊÊÊÊ* ‡6
/ Óx £™ÈÉä°{£ £°Î Ó°n Îΰä n{ ä°ää{n £]{™n xääÉ,
{ÊÝÊÎxÊÊÊÊÊÊÊÊ* ‡6
/ Îx ÓÇÈÉä°{£ £°Î ΰ£ ÎÇ°ä £ä{ ä°ää{£ Ó]ääÇ xääÉ,

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 25
PHELPS DODGE CONDUCTOR TYPE PD-VTF
300 V 70oC PVC INSULATED TWISTED, FLEXIBLE TWO CORE
Application :
For used mainly for small indoor
electrical appliances such as
desk-lamp, radios, fans, electric hot
plate etc.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not exceed
300 volts.
Conductor
Reference Standard :
TIS 11-2531 TABLE 10

Construction :
Conductor : Annealed copper,
bunch stranded
2 2
Sizes 0.5 mm up to 2.5 mm PVC insulation

Insulation : Heat resistance polyvinyl


chloride (Gray and Black colour)

-IN.UMBER !LLOWABLE -INIMUM


.OMINAL 4HICKNESS #ABLE
-AX$IAMETER /VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL OF 7EIGHT
OF7IRE $IAMETER &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA )NSULATION APPROX
.OMM MM —# AT—# M
MM MM KGKM
! - KM
ÓÉ
Êä°xÊÊÊÊÊÊ* ‡6/ ä°x ÓnÉä°£È ä°n Î°Ó ££ ä°ä£Èä Ó{ £ääÉ

ÓÉ
Êä°xÊÊÊÊÊ* ‡6/ ä°x £ÈÉä°Ó£ ä°n Î°Ó ££ ä°ä£Èä Ó{ £ääÉ

ÓÉ
Êä°ÇxÊÊÊÊ* ‡6/ ä°Çx {ÓÉä°£È ä°n ΰ{ £{ ä°ä£{ä Îä £ääÉ

ÓÉ
Êä°ÇxÊÊÊÊ* ‡6/ ä°Çx Ó{Éä°Ó£ ä°n ΰ{ £{ ä°ä£{ä Îä £ääÉ

ÓÉ
Ê£ÊÊÊÊÊÊÊÊÊ* ‡6/ £ ÎÓÉä°Ó£ ä°n Î°È £È ä°ä£ÓÇ ÎÈ £ääÉ

ÓÉ
Ê£°xÊÊÊÊÊÊ* ‡6/ £°x ÎäÉä°ÓÈ ä°n ΰ™ Ó£ ä°ä£££ {Ç £ääÉ

ÓÉ
ÊÓ°xÊÊÊÊÊÊ* ‡6/ Ó°x xäÉä°ÓÈ ä°n {°n ә ä°ää™Ó Çä £ääÉ

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
26 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VFF
300 V 70oC PVC INSULATED FLAT TYPE, FLEXIBLE TWO CORE
Application :
For used in dryroom for small indoor
electrical appliances such as
desk-lamp, radios, fans etc.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not exceed
300 volts.
Conductor
Reference Standard : PVC insulation
TIS 11-2531 TABLE 10

Construction :
Conductor : Annealed copper,
bunch stranded
2 2
Sizes 0.5 mm up to 2.5 mm

Insulation : Heat resistance polyvinyl


chloride (Any colour as requested)

-IN.UMBER !LLOWABLE -INIMUM


.OMINAL 4HICKNESS #ABLE
-AX$IAMETER /VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL OF 7EIGHT
OF7IRE $IAMETER &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA )NSULATION APPROX
.OMM MM —# AT—# M
MM 
MM KGKM
! - KM
ÓÊÝÊä°xÊÊÊÊÊ* ‡6 ä°x ÓnÉä°£È ä°n ΰÓÊÝÊÈ°Ó ££ ä°ä£Èä ÓÓ £ääÉ

ÓÊÝÊä°xÊÊÊÊÊ* ‡6 ä°x £ÈÉä°Ó£ ä°n ΰÓÊÝÊÈ°Ó ££ ä°ä£Èä ÓÓ £ääÉ

ÓÊÝÊä°ÇxÊÊÊÊ* ‡6 ä°Çx {ÓÉä°£È ä°n ΰ{ÊÝÊÈ°È £{ ä°ä£{ä Ón £ääÉ

ÓÊÝÊä°ÇxÊÊÊÊ* ‡6 ä°Çx Ó{Éä°Ó£ ä°n ΰ{ÊÝÊÈ°È £{ ä°ä£{ä Ón £ääÉ

ÓÊÝÊ£ÊÊÊÊÊÊÊÊÊ* ‡6 £ ÎÓÉä°Ó£ ä°n ΰÈÊÝÊÇ°ä £È ä°ä£ÓÇ ÎÎ £ääÉ

ÓÊÝÊ£°xÊÊÊÊÊÊ* ‡6 £°x ÎäÉä°ÓÈ ä°n ΰ™ÊÝÊÇ°È Ó£ ä°ä£££ {{ £ääÉ

ÓÊÝÊÓ°xÊÊÊÊÊÊ* ‡6 Ó°x xäÉä°ÓÈ ä°n {°nÊÝʙ°{ ә ä°ää™Ó Èx £ääÉ

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 27
PHELPS DODGE CONDUCTOR TYPE PD-VSF
300 V 70oC PVC INSULATED, FLEXIBLE SINGLE CORE
Application :
For making cross connection
between terminals inside appliances,
instruments or apparatus.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.

Reference Standard :
TIS 11-2531 TABLE 10
Conductor
PVC insulation
Construction :
Conductor : Annealed copper,
bunch stranded
2 2
Sizes 0.5 mm up to 2.5 mm

Insulation : Polyvinyl chloride (Any


colour as requested)

-IN.UMBER !LLOWABLE -INIMUM


.OMINAL 4HICKNESS #ABLE
-AX$IAMETER /VERALL !MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL OF 7EIGHT
OF7IRE $IAMETER &REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA )NSULATION APPROX
.OMM MM —# AT—# M
MM MM KGKM
! - KM
£ÊÝÊä°xÊÊÊÊÊÊ* ‡6- ä°x ÓnÉä°£È ä°n Ó°™ ££ ä°ä£Èä £Ó £ääÉ

£ÊÝÊä°xÊÊÊÊÊÊ* ‡6- ä°x £ÈÉä°Ó£ ä°n Ó°™ ££ ä°ä£Èä £Ó £ääÉ

£ÊÝÊä°ÇxÊÊÊÊ* ‡6- ä°Çx {ÓÉä°£È ä°n ΰ£ £{ ä°ä£{ä £x £ääÉ

£ÊÝÊä°ÇxÊÊÊÊ* ‡6- ä°Çx Ó{Éä°Ó£ ä°n ΰ£ £{ ä°ä£{ä £x £ääÉ

£ÊÝÊ£ÊÊÊÊÊÊÊÊÊ* ‡6- £ ÎÓÉä°Ó£ ä°n ΰΠ£È ä°ä£ÓÇ £n £ääÉ

£ÊÝÊ£°xÊÊÊÊÊÊ* ‡6- £°x ÎäÉä°ÓÈ ä°n Î°È Ó£ ä°ä£££ ÓÎ £ääÉ

£ÊÝÊÓ°xÊÊÊÊÊÊ* ‡6- Ó°x xäÉä°ÓÈ ä°n {°ä ә ä°ää™Ó ÎÎ £ääÉ

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
28 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VAF-G (MEA TYPE B-GRD)
300 V 70oC PVC INSULATED AND SHEATHED FLAT TYPE, TWO CORE WITH GROUND
Application :
Surfaced wiring. Concealed wiring
in wooden partition, or above ceiling.
Embed in plaster

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.

Reference Standard : Phase Conductor


TIS 11-2531 TABLE 11

PVC Insulation

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 35 mm (Phase)
2 2
Sizes 1 mm up to 10 mm (Ground)
PVC Sheath
Insulation : Polyvinyl chloride (Gray Ground Conductor
and Black colour) Phase, (Green
with Yellow Stripe colour) Ground

Sheath : Polyvinyl chloride (White


colour)

0HASECORE 'ROUNDCORE
!LLOWABLE -INIMUM
.OMINAL .UMBER 4HICKNESS .OMINAL .UMBER 4HICKNESS 4HICKNESS /VERALL #ABLE
!MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL $IAMETER OF 3ECTIONAL $IAMETER OF OF $IMENSION 7EIGHT
&REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA OF7IRE )NSULATION !REA OF7IRE )NSULATION 3HEATH APPROX
—# AT—# M
MM 
.OMM MM MM 
.OMM MM MM MM KGKM
! - KM

ÓÊÝʣɣÊÊÊÊÊÊÊ* ‡6‡ £ £É£°£Î ä°È £ £É£°£Î ä°È 䰙 {°nÊÝÊ£ä°ä £Î ä°ä££x Çä £ääÉ

ÓÊÝʣɣÊÊÊÊÊÊÊ* ‡6‡ £ ÇÉä°{ä ä°È £ ÇÉä°{ä ä°È 䰙 x°äÊÝÊ£ä°x £Î ä°ä££ä Çä £ääÉ

ÓÊÝÊ£°xÉ£ÊÊÊÊ* ‡6‡ £°x £É£°În ä°È £ £É£°£Î ä°È £°Ó x°nÊÝÊ££°x £Ç ä°ä£ää ™x £ääÉ

ÓÊÝÊ£°xÉ£ÊÊÊÊ* ‡6‡ £°x ÇÉä°xä ä°È £ ÇÉä°{ä ä°È £°Ó È°äÊÝÊ£Ó°ä £Ç ä°ää™{ ™x £ääÉ

ÓÊÝÊÓ°xÉ£°xÊ* ‡6‡ Ó°x £É£°Çn ä°Ç £°x £É£°În ä°È £°Ó È°{ÊÝʣΰä ÓÎ ä°ää™Ó £Îä £ääÉ

ÓÊÝÊÓ°xÉ£°xÊ* ‡6‡ Ó°x ÇÉä°ÈÇ ä°Ç £°x ÇÉä°xä ä°È £°Ó È°nÊÝÊ£{°ä ÓÎ ä°ään{ £Îä £ääÉ

ÓÊÝÊ{ÉÓ°xÊÊÊÊ* ‡6‡ { £ÉÓ°Óx ä°n Ó°x £É£°Çn ä°È £°Ó Ç°ÓÊÝÊ£x°ä Îä ä°äänÈ £™ä £ääÉ

ÓÊÝÊ{ÉÓ°xÊÊÊÊ* ‡6‡ { ÇÉä°nx ä°n Ó°x ÇÉä°ÈÇ ä°È £°Ó Ç°ÈÊÝʣȰä Îä ä°ääÇn £™ä £ääÉ

ÓÊÝÊÈÉ{ÊÊÊÊÊÊÊ* ‡6‡ È ÇÉ£°ä{ ä°n { ÇÉä°nx ä°È £°Ó n°ÓÊÝʣǰx {ä ä°ääÈÈ ÓÇä £ääÉ

ÓÊÝÊ£äÉ{ÊÊÊÊÊ* ‡6‡ £ä ÇÉ£°Îx 䰙 { ÇÉä°nx ä°È £°Ó ™°{ÊÝÊÓä°ä xx ä°ääx™ Înä £ääÉ

ÓÊÝÊ£ÈÉÈÊÊÊÊÊ* ‡6‡ £È ÇÉ£°Çä £°ä È ÇÉ£°ä{ ä°È £°Ó ££°äÊÝÊÓΰä Ç{ ä°ääxÎ xxä xääÉ,
ÓÊÝÊÓxÉÈÊÊÊÊÊ* ‡6‡ Óx ÇÉÓ°£{ £°Ó È ÇÉ£°ä{ ä°È £°{ £Î°äÊÝÊÓÇ°ä ™Ç ä°ääx£ n£ä xääÉ,
ÓÊÝÊÎxÉ£äÊÊÊ* ‡6‡ Îx £™É£°xÎ £°Ó £ä ÇÉ£°Îx ä°È £°{ £{°xÊÝÊΣ°ä £Óä ä°ää{Î £]äÇä xääÉ,

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 29
PHELPS DODGE CONDUCTOR TYPE PD-VAF-G
300 V 70oC PVC INSULATED AND SHEATHED FLAT TYPE, THREE CORE WITH GROUND
Application :
Surfaced wiring. Concealed wiring
in wooden partition, or above ceiling.
Embed in plaster.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.

Reference Standard : Ground Conductor


TIS 11-2531 TABLE 11

PVC Sheath
Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 16 mm (Phase)
2 2
Sizes 1 mm up to 6 mm (Ground)

Insulation : Heat resistance polyvinyl PVC Insulation


chloride (Gray, Black and Red
colour) Phase, (Green with Yellow
Stripe colour) Ground Phase Conductor

Sheath : Heat resistance Polyvinyl


chloride (White colour)

0HASECORE 'ROUNDCORE
!LLOWABLE -INIMUM
.OMINAL .UMBER 4HICKNESS .OMINAL .UMBER 4HICKNESS 4HICKNESS /VERALL #ABLE
!MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL $IAMETER OF 3ECTIONAL $IAMETER OF OF $IMENSION 7EIGHT
&REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA OF7IRE )NSULATION !REA OF7IRE )NSULATION 3HEATH APPROX
—# AT—# M
MM 
.OMM MM MM 
.OMM MM MM MM KGKM
! - KM
ÎÊÝʣɣÊÊÊÊÊÊÊ* ‡6‡ £ £É£°£Î ä°È £ £É£°£Î ä°È 䰙 {°nÊÝÊ£Ó°x ££°x ä°ä££x ™x £ääÉ

ÎÊÝʣɣÊÊÊÊÊÊÊ* ‡6‡ £ ÇÉä°{ä ä°È £ ÇÉä°{ä ä°È 䰙 x°äÊÝʣΰx ££°x ä°ä££ä ™x £ääÉ

ÎÊÝÊ£°xÉ£ÊÊÊÊ* ‡6‡ £°x £É£°În ä°È £ £É£°£Î ä°È £°Ó x°nÊÝÊ£{°ä £x ä°ä£ää £Îä £ääÉ

ÎÊÝÊ£°xÉ£ÊÊÊÊ* ‡6‡ £°x ÇÉä°xä ä°È £ ÇÉä°{ä ä°È £°Ó È°äÊÝÊ£x°ä £x ä°ää™{ £Îä £ääÉ

ÎÊÝÊÓ°xÉ£°xÊ* ‡6‡ Ó°x £É£°Çn ä°Ç £°x £É£°În ä°È £°Ó È°{ÊÝʣȰx Ó£ ä°ää™Ó £nä £ääÉ

ÎÊÝÊÓ°xÉ£°xÊ* ‡6‡ Ó°x ÇÉä°ÈÇ ä°Ç £°x ÇÉä°xä ä°È £°Ó È°nÊÝʣǰx Ó£ ä°ään{ £nä £ääÉ

ÎÊÝÊ{ÉÓ°xÊÊÊÊ* ‡6‡ { £ÉÓ°Óx ä°n Ó°x £É£°Çn ä°È £°Ó Ç°ÓÊÝÊ£™°ä Ón ä°äänÈ ÓÈä £ääÉ

ÎÊÝÊ{ÉÓ°xÊÊÊÊ* ‡6‡ { ÇÉä°nx ä°n Ó°x ÇÉä°ÈÇ ä°È £°Ó Ç°ÈÊÝÊÓä°x Ón ä°ääÇn ÓÈä £ääÉ

ÎÊÝÊÈÉ{ÊÊÊÊÊÊÊ* ‡6‡ È ÇÉ£°ä{ ä°n { ÇÉä°nx ä°È £°Ó n°ÓÊÝÊÓÓ°x ÎÈ ä°ääÈÈ ÎÇä £ääÉ

ÎÊÝÊ£äÉ{ÊÊÊÊÊ* ‡6‡ £ä ÇÉ£°Îx 䰙 { ÇÉä°nx ä°È £°Ó ™°{ÊÝÊÓÈ°ä xä ä°ääx™ xÓä £ääÉ

ÎÊÝÊ£ÈÉÈÊÊÊÊÊ* ‡6‡ £È ÇÉ£°Çä £°ä È ÇÉ£°ä{ ä°È £°{ ££°äÊÝÊΣ°x ÈÈ ä°ääxÎ nÈä £ääÉ

C = Packing in coil

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
30 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VVR-G
300 V 70oC PVC INSULATED AND SHEATHED, TWO CORE WITH GROUND
Application :
Exposed wiring in air or in raceway.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.

Reference Standard :
TIS 11-2531 TABLE 12
Phase Conductor

Construction : PVC Insulation


Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 35 mm (Phase)
2 2
Sizes 1 mm up to 10 mm (Ground)

Insulation : Heat resistance polyvinyl


chloride (Gray and Black colour) PVC Sheath
Phase, (Green with Yellow Stripe
colour) Ground
Ground Conductor
Sheath : Heat resistance polyvinyl
chloride (Black colour)

0HASECORE 'ROUNDCORE
!LLOWABLE -INIMUM
.OMINAL .UMBER 4HICKNESS .OMINAL .UMBER 4HICKNESS 4HICKNESS /VERALL #ABLE
!MPACITIES )NSULATION 3TANDARD
0(%,03$/$'% 3ECTIONAL $IAMETER OF 3ECTIONAL $IAMETER OF OF $IMENSION 7EIGHT
&REE!IR 2ESISTANCE 0ACKING
490%,%44%2 !REA OF7IRE )NSULATION !REA OF7IRE )NSULATION 3HEATH APPROX
—# AT—# M
MM 
.OMM MM MM 
.OMM MM MM MM KGKM
! - KM
ÓÊÝʣɣÊÊÊÊÊÊ* ‡66,‡ £ £É£°£Î ä°È £ £É£°£Î ä°È 䰙 n°ä £Î ä°ä££x nä xääÉ,
ÓÊÝʣɣÊÊÊÊÊÊÊ* ‡66,‡ £ ÇÉä°{ä ä°È £ ÇÉä°{ä ä°È 䰙 n°{ £Î ä°ä££ä nä xääÉ,
ÓÊÝÊ£°xÉ£ÊÊÊÊ* ‡66,‡ £°x £É£°În ä°È £ £É£°£Î ä°È £°Ó ™°Ó £Ç ä°ä£ää £ää xääÉ,
ÓÊÝÊ£°xÉ£ÊÊÊÊ* ‡66,‡ £°x ÇÉä°xä ä°È £ ÇÉä°{ä ä°È £°Ó ™°È £Ç ä°ää™{ £ää xääÉ,
ÓÊÝÊÓ°xÉ£°xÊ* ‡66,‡ Ó°x £É£°Çn ä°Ç £°x £É£°În ä°È £°Ó £ä°x ÓÎ ä°ää™Ó £{ä xääÉ,
ÓÊÝÊÓ°xÉ£°xÊ* ‡66,‡ Ó°x ÇÉä°ÈÇ ä°Ç £°x ÇÉä°xä ä°È £°Ó ££°x ÓÎ ä°ään{ £{ä xääÉ,
ÓÊÝÊ{ÉÓ°xÊÊÊÊ* ‡66,‡ { £ÉÓ°Óx ä°n Ó°x £É£°Çn ä°È £°Ó £Ó°x Îä ä°äänÈ Óää xääÉ,
ÓÊÝÊ{ÉÓ°xÊÊÊÊ* ‡66,‡ { ÇÉä°nx ä°n Ó°x ÇÉä°ÈÇ ä°È £°Ó £Î°ä Îä ä°ääÇn Óää xääÉ,
ÓÊÝÊÈÉ{ÊÊÊÊÊÊÊ* ‡66,‡ È ÇÉ£°ä{ ä°n { ÇÉä°nx ä°È £°Ó £{°x {ä ä°ääÈÈ Ó™ä xääÉ,
ÓÊÝÊ£äÉ{ÊÊÊÊÊ* ‡66,‡ £ä ÇÉ£°Îx 䰙 { ÇÉä°nx ä°È £°Ó £È°ä xx ä°ääx™ {£ä xääÉ,
ÓÊÝÊ£ÈÉÈÊÊÊÊÊ* ‡66,‡ £È ÇÉ£°Çä £°ä È ÇÉ£°ä{ ä°È £°{ £™°ä Ç{ ä°ääxΠȣä xääÉ,
ÓÊÝÊÓxÉÈÊÊÊÊÊ* ‡66,‡ Óx ÇÉÓ°£{ £°Ó È ÇÉ£°ä{ ä°È £°{ ÓÓ°x ™Ç ä°ääx£ nnä xääÉ,
ÓÊÝÊÎxÉ£äÊÊÊ* ‡66,‡ Îx £™É£°xÎ £°Ó £ä ÇÉ£°Îx ä°È £°{ Óx°x £Óä ä°ää{Î £]£ÇÈ xääÉ,

R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 31
PHELPS DODGE CONDUCTOR TYPE PD-VVR-G
300 V 70oC PVC INSULATED AND SHEATHED, THREE CORE WITH GROUND
Application :
Exposed wiring in air or in raceway.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not exceed
300 volts.
Phase Conductor

Reference Standard :
TIS 11-2531 TABLE 12 PVC Insulation

Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 35 mm (Phase)
2 2
Sizes 1 mm up to 10 mm (Ground) PVC Sheath

Insulation : Heat resistance polyvinyl Ground Conductor


chloride (Gray, Black and Red
colour) Phase, (Green with Yellow
Stripe colour) Ground

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Number & Thickness Nominal Number & Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Insulation Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath Diameter Max (approx)
40°C at 70°C m
mm2 No. / mm mm mm2 No. / mm mm mm mm kg / km
A M - km
3 x 1/1 PD-VVR-G 1 1/1.13 0.6 1 1/1.13 0.6 0.9 8.6 11.5 0.0115 95 500/R
3 x 1/1 PD-VVR-G 1 7/0.40 0.6 1 7/0.40 0.6 0.9 9.0 11.5 0.0110 95 500/R
3 x 1.5/1 PD-VVR-G 1.5 1/1.38 0.6 1 1/1.13 0.6 1.2 10.0 15 0.0100 130 500/R
3 x 1.5/1 PD-VVR-G 1.5 7/0.50 0.6 1 7/0.40 0.6 1.2 10.5 15 0.0094 130 500/R
3 x 2.5/1.5 PD-VVR-G 2.5 1/1.78 0.7 1.5 1/1.38 0.6 1.2 11.5 21 0.0092 180 500/R
3 x 2.5/1.5 PD-VVR-G 2.5 7/0.67 0.7 1.5 7/0.50 0.6 1.2 12.5 21 0.0084 180 500/R
3 x 4/2.5 PD-VVR-G 4 1/2.25 0.8 2.5 1/1.78 0.6 1.2 13.5 28 0.0086 260 500/R
3 x 4/2.5 PD-VVR-G 4 7/0.85 0.8 2.5 7/0.67 0.6 1.2 14.0 28 0.0078 260 500/R
3 x 6/4 PD-VVR-G 6 7/1.04 0.8 4 7/0.85 0.6 1.2 15.5 36 0.0066 370 500/R
3 x 10/4 PD-VVR-G 10 7/1.35 0.9 4 7/0.85 0.6 1.2 18.5 50 0.0059 530 500/R
3 x 16/6 PD-VVR-G 16 7/1.70 1.0 6 7/1.04 0.6 1.4 22.0 66 0.0053 800 500/R
3 x 25/6 PD-VVR-G 25 7/2.14 1.2 6 7/1.04 0.6 1.8 27.5 84 0.0051 1,220 500/R
3 x 35/10 PD-VVR-G 35 19/1.53 1.2 10 7/1.35 0.6 1.8 30.5 104 0.0043 1,610 500/R

R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
32 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VVR-G
300 V 70oC PVC INSULATED AND SHEATHED, FOUR CORE WITH GROUND
Application :
Exposed wiring in air or in raceway.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.

Reference Standard : Phase Conductor


TIS 11-2531 TABLE 12

PVC Insulation

Construction :
Conductor : Annealed copper, solid
or stranded PVC Sheath
2 2
Sizes 1 mm up to 35 mm (Phase)
2 2
Sizes 1 mm up to 10 mm (Ground)
Ground Conductor
Insulation : Heat resistance polyvinyl
chloride (Gray, Black Red and Blue
colour) Phase, (Green with Yellow
Stripe colour) Ground

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Number & Thickness Nominal Number & Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Insulation Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath Diameter Max (approx)
2 2
40°C at 70°C m
mm No. / mm mm mm No. / mm mm mm mm kg / km
A M - km
4 x 1/1 PD-VVR-G 1 1/1.13 0.6 1 1/1.13 0.6 0.9 9.2 11.5 0.0115 110 500/R
4 x1/1 PD-VVR-G 1 7/0.40 0.6 1 7/0.40 0.6 0.9 9.8 11.5 0.0110 110 500/R
4 x 1.5/1 PD-VVR-G 1.5 1/1.38 0.6 1 1/1.13 0.6 1.2 11.0 15 0.0100 150 500/R
4 x 1.5/1 PD-VVR-G 1.5 7/0.50 0.6 1 7/0.40 0.6 1.2 11.5 15 0.0094 150 500/R
4 x 2.5/1.5 PD-VVR-G 2.5 1/1.78 0.7 1.5 1/1.38 0.6 1.2 12.5 21 0.0092 220 500/R
4 x 2.5/1.5 PD-VVR-G 2.5 7/0.67 0.7 1.5 7/0.50 0.6 1.2 13.5 21 0.0084 220 500/R
4 x 4/2.5 PD-VVR-G 4 1/2.25 0.8 2.5 1/1.78 0.6 1.2 14.5 28 0.0086 330 500/R
4 x 4/2.5 PD-VVR-G 4 7/0.85 0.8 2.5 7/0.67 0.6 1.2 15.5 28 0.0078 330 500/R
4 x 6/4 PD-VVR-G 6 7/1.04 0.8 4 7/0.85 0.6 1.2 17.0 36 0.0066 470 500/R
4 x 10/4 PD-VVR-G 10 7/1.35 0.9 4 7/0.85 0.6 1.4 20.5 50 0.0059 700 500/R
4 x 16/6 PD-VVR-G 16 7/1.70 1.0 6 7/1.04 0.6 1.4 24.5 66 0.0053 1,030 500/R
4 x 25/6 PD-VVR-G 25 7/2.14 1.2 6 7/1.04 0.6 1.8 30.0 84 0.0051 1,570 500/R
4 x 35/10 PD-VVR-G 35 19/1.53 1.2 10 7/1.35 0.6 1.8 33.5 104 0.0043 2,070 500/R

R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 33
PHELPS DODGE CONDUCTOR TYPE PD-VVF-G
750 V 70oC PVC INSULATED AND SHEATHED, FLAT TYPE, TWO CORE WITH GROUND
Application :
For fixed installation in damp
location. The cable is suitable for
surface wiring or concealed wiring
in wooden partition. The ground
conductor accompany in the cable
caused the cable being suitable for
use in grounded electrical system.

Classification :
Maximum conductor temperature
o Phase Conductor
70 C Circuit voltage does not
exceed 750 volts.
PVC Insulation
Reference Standard :
TIS 11-2531 TABLE 13

Construction :
Conductor : Annealed copper, solid
or stranded PVC Sheath
2 2
Sizes 1 mm up to 35 mm (Phase)
2 2
Sizes 1 mm up to 10 mm (Ground) Ground Conductor

Insulation : Heat resistance polyvinyl


chloride (Gray and Black colour)
Phase, (Green with Yellow Stripe
colour) Ground

Sheath : Heat resistance polyvinyl


chloride (White colour)

Phase core Ground core


Allowable Minimum
Nominal Number & Thickness Nominal Number & Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Dimension Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath (approx)
40°C at 70°C m
mm2 No. / mm mm mm2 No. / mm mm mm mm kg / km
A M - km
2 x 1/1 PD-VVF-G 1 1/1.13 0.8 1 1/1.13 0.6 1.4 6.4 x 12.0 13 0.0141 100 500/R
2 x 1/1 PD-VVF-G 1 7/0.40 0.8 1 7/0.40 0.6 1.4 6.6 x 12.5 13 0.0135 100 500/R
2 x 1.5/1 PD-VVF-G 1.5 1/1.38 0.8 1 1/1.13 0.6 1.4 6.6 x 12.5 17 0.0123 120 500/R
2 x 1.5/1 PD-VVF-G 1.5 7/0.50 0.8 1 7/0.40 0.6 1.4 7.0 x 13.0 17 0.0116 120 500/R
2 x 2.5/1.5 PD-VVF-G 2.5 1/1.78 0.8 1.5 1/1.38 0.6 1.4 7.2 x 14.0 23 0.0102 150 500/R
2 x 2.5/1.5 PD-VVF-G 2.5 7/0.67 0.8 1.5 7/0.50 0.6 1.4 7.4 x 14.5 23 0.0093 150 500/R
2 x 4/2.5 PD-VVF-G 4 1/2.25 0.9 2.5 1/1.78 0.6 1.4 7.8 x 15.5 30 0.0094 210 500/R
2 x 4/2.5 PD-VVF-G 4 7/0.85 0.9 2.5 7/0.67 0.6 1.4 8.2 x 16.5 30 0.0085 210 500/R
2 x 6/4 PD-VVF-G 6 7/1.04 0.9 4 7/0.85 0.6 1.4 8.8 x 18.5 40 0.0073 290 500/R
2 x 10/4 PD-VVF-G 10 7/1.35 1.1 4 7/0.85 0.6 1.5 10.5 x 21.5 55 0.0069 420 500/R
2 x 16/6 PD-VVF-G 16 7/1.70 1.1 6 7/1.04 0.6 1.5 11.5 x 24.5 74 0.0057 590 500/R
2 x 25/6 PD-VVF-G 25 7/2.14 1.3 6 7/1.04 0.6 1.6 13.5 x 28.0 97 0.0054 840 500/R
2 x 35/10 PD-VVF-G 35 19/1.53 1.3 10 7/1.35 0.6 1.7 15.0 x 32.0 120 0.0047 1,120 500/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
34 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE PD-NYY-G)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, TWO CORE WITH GROUND
Application :
Exposed wiring in air or use in
raceway wet or dry location, direct
burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts.
Phase Conductor
Reference Standard :
TIS 11-2531 TABLE 14
PVC Insulation

Construction : PVC Sheath


Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm (Phase)
2 2
Sizes 1 mm up to 35 mm (Ground)

Insulation : Heat resistance polyvinyl


chloride (Gray and Black colour) PVC Inner Sheath
Phase, (Green with Yellow Stripe
colour) Ground.
Ground Conductor
Inner sheath : Heat resistance
polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Number & Thickness Nominal Number & Thickness Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Inner of Outer Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath Sheath (approx)
40°C at 70°C m
mm2 No. / mm mm mm 2
No. / mm mm mm mm mm kg / km
A M - km
2 x 1/1 PD-NYY-G 1 1/1.13 0.8 1 1/1.13 0.6 0.8 1.8 12.5 13 0.0141 170 500/R
2 x 1/1 PD-NYY-G 1 7/0.40 0.8 1 7/0.40 0.6 0.8 1.8 13.0 13 0.0135 170 500/R
2 x 1.5/1 PD-NYY-G 1.5 1/1.38 0.8 1 1/1.13 0.6 0.8 1.8 13.0 17 0.0123 190 500/R
2 x 1.5/1 PD-NYY-G 1.5 7/0.50 0.8 1 7/0.40 0.6 0.8 1.8 13.5 17 0.0116 190 500/R
2 x 2.5/1.5 PD-NYY-G 2.5 1/1.78 0.8 1.5 1/1.38 0.6 0.8 1.8 14.0 23 0.0102 230 500/R
2 x 2.5/1.5 PD-NYY-G 2.5 7/0.67 0.8 1.5 7/0.50 0.6 0.8 1.8 15.0 23 0.0093 230 500/R
2 x 4/2.5 PD-NYY-G 4 1/2.25 0.9 2.5 1/1.78 0.6 0.8 1.8 15.5 30 0.0094 300 500/R
2 x 4/2.5 PD-NYY-G 4 7/0.85 0.9 2.5 7/0.67 0.6 0.8 1.8 16.5 30 0.0085 300 500/R
2 x 6/4 PD-NYY-G 6 7/1.04 0.9 4 7/0.85 0.6 0.8 1.8 18.0 40 0.0073 400 500/R
2 x 10/4 PD-NYY-G 10 7/1.35 1.1 4 7/0.85 0.6 0.8 1.8 19.5 55 0.0069 550 500/R
2 x 16/6 PD-NYY-G 16 7/1.70 1.1 6 7/1.04 0.6 0.8 2.0 22.5 74 0.0057 760 500/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 35
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE C-GRD)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, TWO CORE WITH GROUND
Application :
Exposed wiring in air or use in
raceway wet or dry location, direct
burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts.

Reference Standard : Phase Conductor


TIS 11-2531 TABLE 14

PVC Insulation
Construction : PVC Sheath
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm (Phase)
2 2
Sizes 1 mm up to 35 mm (Ground)

Insulation : Heat resistance polyvinyl


chloride (Gray and Black colour) PVC Inner Sheath
Phase, (Green with Yellow Stripe
colour) Ground.
Ground Conductor
Inner sheath : Heat resistance
polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Number & Thickness Nominal Number & Thickness Thickness Thickness Overall Cable
Ampacities Insulation
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Inner of Outer Diameter Weight Standard
Free Air Resistance
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath Sheath (approx) Packing
40°C at 70°C m
mm 2
No. / mm mm mm 2
No. / mm mm mm mm mm kg / km
A M - km

2 x 25/6 PD-NYY-G 25 7/2.14 1.3 6 7/1.04 0.6 1.2 2.0 27.0 97 0.0054 1,110 500/R
2 x 35/10 PD-NYY-G 35 19/1.53 1.3 10 7/1.35 0.6 1.2 2.0 29.5 120 0.0047 1,410 500/R
2 x 50/10 PD-NYY-G 50 19/1.78 1.5 10 7/1.35 0.6 1.2 2.2 33.5 146 0.0046 1,900 500/R
2 x 70/10 PD-NYY-G 70 19/2.14 1.5 10 7/1.35 0.6 1.5 2.2 38.0 185 0.0039 2,430 500/R
2 x 95/16 PD-NYY-G 95 19/2.52 1.7 16 7/1.70 0.6 1.5 2.2 42.5 224 0.0038 3,230 500/R
2 x 120/16 PD-NYY-G 120 37/2.03 1.7 16 7/1.70 0.6 1.5 2.4 46.5 260 0.0034 3,920 500/R
2 x 150/25 PD-NYY-G 150 37/2.25 1.9 25 7/2.14 0.6 1.8 2.6 52.0 299 0.0034 4,870 200/R
2 x 185/25 PD-NYY-G 185 37/2.52 2.1 25 7/2.14 0.6 1.8 2.8 57.0 341 0.0034 5,940 200/R
2 x 240/35 PD-NYY-G 240 61/2.25 2.3 35 19/1.53 0.6 2.0 3.0 64.0 401 0.0033 7,680 150/R
2 x 300/35 PD-NYY-G 300 61/2.52 2.5 35 19/1.53 0.6 2.0 3.2 70.5 461 0.0032 9,350 150/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
36 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE CORE WITH GROUND
Application :
Exposed wiring in air or use in
raceway wet or dry location, direct
burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts.

Reference Standard : Phase Conductor


TIS 11-2531 TABLE 14
PVC Insulation

PVC Outer Sheath


Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm (Phase)
2 2
Sizes 1 mm up to 35 mm (Ground)

Insulation : Heat resistance polyvinyl


chloride (Gray, Black and Red PVC Inner Sheath
colour) Phase, (Green with Yellow
Stripe colour) Ground.
Ground Conductor
Inner sheath : Heat resistance
polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Number & Thickness Nominal Number & Thickness Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Inner of Outer Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath Sheath (approx)
40°C at 70°C m
mm2 No. / mm mm mm2 No. / mm mm mm mm mm kg / km
A M - km

3 x 1/1 PD-NYY-G 1 1/1.13 0.8 1 1/1.13 0.6 0.8 1.8 13.5 11.5 0.0141 200 500/R
3 x 1/1 PD-NYY-G 1 7/0.40 0.8 1 7/0.40 0.6 0.8 1.8 14.0 11.5 0.0135 200 500/R
3 x 1.5/1 PD-NYY-G 1.5 1/1.38 0.8 1 1/1.13 0.6 0.8 1.8 14.0 15 0.0123 220 500/R
3 x 1.5/1 PD-NYY-G 1.5 7/0.50 0.8 1 7/0.40 0.6 0.8 1.8 14.5 15 0.0116 220 500/R
3 x 2.5/1.5 PD-NYY-G 2.5 1/1.78 0.8 1.5 1/1.38 0.6 0.8 1.8 15.0 21 0.0102 270 500/R
3 x 2.5/1.5 PD-NYY-G 2.5 7/0.67 0.8 1.5 7/0.50 0.6 0.8 1.8 16.0 21 0.0093 270 500/R
3 x 4/2.5 PD-NYY-G 4 1/2.25 0.9 2.5 1/1.78 0.6 0.8 1.8 17.0 28 0.0094 360 500/R
3 x 4/2.5 PD-NYY-G 4 7/0.85 0.9 2.5 7/0.67 0.6 0.8 1.8 17.5 28 0.0085 360 500/R
3 x 6/4 PD-NYY-G 6 7/1.04 0.9 4 7/0.85 0.6 0.8 1.8 19.0 36 0.0073 490 500/R
3 x 10/4 PD-NYY-G 10 7/1.35 1.1 4 7/0.85 0.6 0.8 1.8 22.5 50 0.0069 690 500/R
3 x 16/6 PD-NYY-G 16 7/1.70 1.1 6 7/1.04 0.6 1.2 2.0 26.5 66 0.0057 1,010 500/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 37
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE C-GRD)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE CORE WITH GROUND
Application :
Exposed wiring in air or use in
raceway wet or dry location, direct
burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts.
Phase Conductor
Reference Standard :
TIS 11-2531 TABLE 14
PVC Insulation

Construction : PVC Outer Sheath


Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm (Phase)
2 2
Sizes 1 mm up to 35 mm (Ground)

Insulation : Heat resistance polyvinyl


chloride (Gray, Black and Red PVC Inner Sheath
colour) Phase, (Green with Yellow
Stripe colour) Ground.
Ground Conductor
Inner sheath : Heat resistance
polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Number & Thickness Nominal Number & Thickness Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Inner of Outer Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath Sheath (approx)
2 2 40°C at 70°C m
mm No. / mm mm mm No. / mm mm mm mm mm kg / km
A M - km
3 x 25/6 PD-NYY-G 25 7/2.14 1.3 6 7/1.04 0.6 1.2 2.0 31.0 84 0.0054 1,410 500/R
3 x 35/10 PD-NYY-G 35 19/1.53 1.3 10 7/1.35 0.6 1.2 2.0 34.0 104 0.0047 1,820 300/R
3 x 50/10 PD-NYY-G 50 19/1.78 1.5 10 7/1.35 0.6 1.5 2.2 36.0 125 0.0046 2,510 300/R
3 x 70/10 PD-NYY-G 70 19/2.14 1.5 10 7/1.35 0.6 1.5 2.2 40.5 160 0.0039 3,170 300/R
3 x 95/16 PD-NYY-G 95 19/2.52 1.7 16 7/1.70 0.6 1.5 2.4 46.0 194 0.0038 4,280 300/R
3 x 120/16 PD-NYY-G 120 37/2.03 1.7 16 7/1.70 0.6 1.8 2.6 50.5 225 0.0034 5,280 300/R
3 x 150/25 PD-NYY-G 150 37/2.25 1.9 25 7/2.14 0.6 1.8 2.8 56.0 256 0.0034 6,460 200/R
3 x 185/25 PD-NYY-G 185 37/2.52 2.1 25 7/2.14 0.6 2.0 3.0 61.5 297 0.0034 7,980 200/R
3 x 240/35 PD-NYY-G 240 61/2.25 2.3 35 19/1.53 0.6 2.0 3.2 69.0 351 0.0033 10,250 150/R
3 x 300/35 PD-NYY-G 300 61/2.52 2.5 35 19/1.53 0.6 2.2 3.4 76.0 404 0.0032 12,600 150/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
38 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE C-GRD)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, FOUR CORE WITH GROUND
Application :
Exposed wiring in air or use in
raceway wet or dry location, direct
burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts. Phase Conductor
Reference Standard :
TIS 11-2531 TABLE 14 PVC Insulation

PVC Outer Sheath


Construction :
Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm (Phase)
2 2
Sizes 1 mm up to 35 mm (Ground)

Insulation : Heat resistance polyvinyl PVC Inner Sheath


chloride (Gray, Black, Red and Blue
colour) Phase, (Green with Yellow
Stripe colour) Ground. Ground Conductor

Inner sheath : Heat resistance


polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Number & Thickness Nominal Number & Thickness Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Inner of Outer Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath Sheath (approx)
2 2 40°C at 70°C m
mm No. / mm mm mm No. / mm mm mm mm mm kg / km
A M - km
4 x 1/1 PD-NYY-G 1 1/1.13 0.8 1 1/1.13 0.6 0.8 1.8 14.0 11.5 0.0141 230 500/R
4 x 1/1 PD-NYY-G 1 7/0.40 0.8 1 7/0.40 0.6 0.8 1.8 14.5 11.5 0.0135 230 500/R
4 x 1.5/1 PD-NYY-G 1.5 1/1.38 0.8 1 1/1.13 0.6 0.8 1.8 15.0 15 0.0123 260 500/R
4 x 1.5/1 PD-NYY-G 1.5 7/0.50 0.8 1 7/0.40 0.6 0.8 1.8 15.5 15 0.0116 260 500/R
4 x 2.5/1.5 PD-NYY-G 2.5 1/1.78 0.8 1.5 1/1.38 0.6 0.8 1.8 16.0 21 0.0102 330 500/R
4 x 2.5/1.5 PD-NYY-G 2.5 7/0.67 0.8 1.5 7/0.50 0.6 0.8 1.8 17.0 21 0.0093 330 500/R
4 x 4/2.5 PD-NYY-G 4 1/2.25 0.9 2.5 1/1.78 0.6 0.8 1.8 18.0 28 0.0094 440 500/R
4 x 4/2.5 PD-NYY-G 4 7/0.85 0.9 2.5 7/0.67 0.6 0.8 1.8 19.0 28 0.0085 440 500/R
4 x 6/4 PD-NYY-G 6 7/1.04 0.9 4 7/0.85 0.6 0.8 1.8 20.5 36 0.0073 600 500/R
4 x 10/4 PD-NYY-G 10 7/1.35 1.1 4 7/0.85 0.6 0.8 2.0 25.0 50 0.0069 880 500/R
4 x 16/6 PD-NYY-G 16 7/1.70 1.1 6 7/1.04 0.6 1.2 2.0 28.5 66 0.0057 1,260 500/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 39
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE C-GRD)
750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, FOUR CORE WITH GROUND
Application :
Exposed wiring in air or use in
raceway wet or dry location, direct
burial in ground.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts.
Phase Conductor
Reference Standard :
TIS 11-2531 TABLE 14
PVC Insulation

Construction : PVC Outer Sheath


Conductor : Annealed copper, solid
or stranded
2 2
Sizes 1 mm up to 300 mm (Phase)
2 2
Sizes 1 mm up to 35 mm (Ground)

Insulation : Heat resistance polyvinyl


chloride (Gray, Black, Red and Blue PVC Inner Sheath
colour) Phase, (Green with Yellow
Stripe colour) Ground.
Ground Conductor
Inner sheath : Heat resistance
polyvinyl chloride (Black colour)

Outer sheath : Heat resistance


polyvinyl chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Number & Thickness Nominal Number & Thickness Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Inner of Outer Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath Sheath (approx)
2 2 40°C at 70°C m
mm No. / mm mm mm No. / mm mm mm mm mm kg / km
A M - km
4 x 25/6 PD-NYY-G 25 7/2.14 1.3 6 7/1.04 0.6 1.2 2.0 33.5 84 0.0054 1,790 300/R
4 x 35/10 PD-NYY-G 35 19/1.53 1.3 10 7/1.35 0.6 1.5 2.2 38.5 104 0.0047 2,390 300/R
4 x 50/10 PD-NYY-G 50 19/1.78 1.5 10 7/1.35 0.6 1.5 2.2 43.5 125 0.0046 3,180 300/R
4 x 70/10 PD-NYY-G 70 19/2.14 1.5 10 7/1.35 0.6 1.5 2.4 44.5 160 0.0039 4,060 300/R
4 x 95/16 PD-NYY-G 95 19/2.52 1.7 16 7/1.70 0.6 1.8 2.6 51.5 194 0.0038 5,550 300/R
4 x 120/16 PD-NYY-G 120 37/2.03 1.7 16 7/1.70 0.6 1.8 2.8 56.0 225 0.0034 6,770 300/R
4 x 150/25 PD-NYY-G 150 37/2.25 1.9 25 7/2.14 0.6 2.0 3.0 62.0 256 0.0034 8,340 200/R
4 x 185/25 PD-NYY-G 185 37/2.52 2.1 25 7/2.14 0.6 2.0 3.2 68.0 297 0.0034 10,240 200/R
4 x 240/35 PD-NYY-G 240 61/2.25 2.3 35 19/1.53 0.6 2.2 3.4 76.5 351 0.0033 13,230 150/R
4 x 300/35 PD-NYY-G 300 61/2.52 2.5 35 19/1.53 0.6 2.2 3.8 84.5 404 0.0032 16,280 150/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
40 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VCT-G
750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE TWO CORE WITH GROUND
Application :
For mobile-electrical equipment
used in mines, factories, farm or
household appliances. Also for
heavy-duty service such as heavy
tools, garage portable lights, and
battery chargers.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not Phase Conductor
exceed 750 volts.

Reference Standard : PVC Insulation


TIS 11-2531 TABLE 15 PVC Sheath

Construction :
Conductor : Annealed copper, bunch
or stranded
2 2
Sizes 1 mm up to 35 mm (Phase)
2 2
Sizes 1 mm up to 10 mm (Ground)

Insulation : Heat resistance polyvinyl Ground Conductor


chloride (Gray and Black colour)
Phase, (Green with Yellow Stripe
colour) Ground

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Min Number & Thickness Nominal Number & Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath (approx)
40°C at 70°C m
mm2 No. / mm mm mm2 No. / mm mm mm mm kg / km
A M - km
2 x 1/1 PD-VCT-G 1 32/0.21 0.8 1 32/0.21 0.6 1.2 10.5 13 0.0127 110 500/R
2 x 1.5/1 PD-VCT-G 1.5 30/0.26 0.8 1 32/0.21 0.6 1.4 11.5 17 0.0111 130 500/R
2 x 2.5/1.5 PD-VCT-G 2.5 50/0.26 0.8 1.5 30/0.26 0.6 1.4 13.0 23 0.0092 170 500/R
2 x 4/2.5 PD-VCT-G 4 56/0.31 0.9 2.5 50/0.26 0.6 1.6 15.5 30 0.0084 250 500/R
2 x 6/4 PD-VCT-G 6 84/0.31 0.9 4 56/0.31 0.6 1.6 17.0 40 0.0071 320 500/R
2 x 10/4 PD-VCT-G 10 80/0.41 1.1 4 56/0.31 0.6 1.8 20.0 55 0.0068 520 500/R
2 x 16/6 PD-VCT-G 16 126/0.41 1.1 6 84/0.31 0.6 2.2 23.0 74 0.0050 730 500/R
2 x 25/6 PD-VCT-G 25 196/0.41 1.3 6 84/0.31 0.6 2.4 27.5 97 0.0048 1,030 500/R
2 x 35/10 PD-VCT-G 35 276/0.41 1.3 10 80/0.41 0.6 2.6 31.0 120 0.0041 1,410 500/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 41
PHELPS DODGE CONDUCTOR TYPE PD-VCT-G
750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE THREE CORE WITH GROUND
Application :
For mobile-electrical equipment
used in mines, factories, farm or
household appliances. Also for
heavy-duty service such as heavy
tools, garage portable lights, and
battery chargers.

Classification : Phase Conductor


Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 750 volts.
PVC Insulation
Reference Standard : PVC Sheath
TIS 11-2531 TABLE 15

Construction :
Conductor : Annealed copper,
bunch stranded
2 2
Sizes 1 mm up to 35 mm (Phase)
2 2
Sizes 1 mm up to 10 mm (Ground)
Ground Conductor
Insulation : Heat resistance
polyvinyl chloride (Gray, Black and
Red colour) Phase, (Green with
Yellow Stripe colour) Ground.

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Min Number & Thickness Nominal Number & Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath (approx)
2 2 40°C at 70°C m
mm No. / mm mm mm No. / mm mm mm mm kg / km
A M - km
3 x 1/1 PD-VCT-G 1 32/0.21 0.8 1 32/0.21 0.6 1.4 11.5 11.5 0.0127 140 500/R
3 x 1.5/1 PD-VCT-G 1.5 30/0.26 0.8 1 32/0.21 0.6 1.4 12.5 15 0.0111 160 500/R
3 x 2.5/1.5 PD-VCT-G 2.5 50/0.26 0.8 1.5 30/0.26 0.6 1.4 14.5 21 0.0092 210 500/R
3 x 4/2.5 PD-VCT-G 4 56/0.31 0.9 2.5 50/0.26 0.6 1.6 17.0 28 0.0084 310 500/R
3 x 6/4 PD-VCT-G 6 84/0.31 0.9 4 56/0.31 0.6 1.8 19.0 36 0.0071 420 500/R
3 x 10/4 PD-VCT-G 10 80/0.41 1.1 4 56/0.31 0.6 2.0 23.5 50 0.0068 680 500/R
3 x 16/6 PD-VCT-G 16 126/0.41 1.1 6 84/0.31 0.6 2.4 27.5 66 0.0050 950 500/R
3 x 25/6 PD-VCT-G 25 196/0.41 1.3 6 84/0.31 0.6 2.6 32.5 84 0.0048 1,350 500/R
3 x 35/10 PD-VCT-G 35 276/0.41 1.3 10 80/0.41 0.6 2.8 36.5 104 0.0041 1,860 500/R
C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
42 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VCT-G
750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE FOUR CORE WITH GROUND
Application :
For mobile-electrical equipment
used in mines, factories, farm or
household appliances. Also for
heavy-duty service such as heavy
tools, garage portable lights, and
battery chargers.

Classification :
Maximum conductor temperature Phase Conductor
o
70 C Circuit voltage does not ex-
ceed 750 volts.
PVC Insulation
Reference Standard :
TIS 11-2531 TABLE 15 PVC Sheath

Construction :
Conductor : Annealed copper,
bunch or stranded
2 2
Sizes 1 mm up to 35 mm (Phase)
2 2
Sizes 1 mm up to 10 mm (Ground) Ground Conductor

Insulation : Heat resistance polyvinyl


chloride (Gray, Black, Red and Blue
colour) Phase, (Green with Yellow
Stripe colour) Ground

Sheath : Heat resistance polyvinyl


chloride (Black colour)

Phase core Ground core


Allowable Minimum
Nominal Min Number & Thickness Nominal Number & Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Diameter of Sectional Diameter of of Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation Sheath (approx)
40°C at 70°C m
mm2 No. / mm mm mm2 No. / mm mm mm mm kg / km
A M - km
4 x 1/1 PD-VCT-G 1 32/0.21 0.8 1 32/0.21 0.6 1.6 13.0 11.5 0.0127 180 500/R
4 x 1.5/1 PD-VCT-G 1.5 30/0.26 0.8 1 32/0.21 0.6 1.6 13.5 15 0.0111 210 500/R
4 x 2.5/1.5 PD-VCT-G 2.5 50/0.26 0.8 1.5 30/0.26 0.6 1.6 16.0 21 0.0092 280 500/R
4 x 4/2.5 PD-VCT-G 4 56/0.31 0.9 2.5 50/0.26 0.6 1.8 18.5 28 0.0084 400 500/R
4 x 6/4 PD-VCT-G 6 84/0.31 0.9 4 56/0.31 0.6 2.0 21.0 36 0.0071 530 500/R
4 x 10/4 PD-VCT-G 10 80/0.41 1.1 4 56/0.31 0.6 2.2 26.0 50 0.0068 1,080 500/R
4 x 16/6 PD-VCT-G 16 126/0.41 1.1 6 84/0.31 0.6 2.6 30.5 66 0.0050 1,280 500/R
4 x 25/6 PD-VCT-G 25 196/0.41 1.3 6 84/0.31 0.6 2.8 36.0 84 0.0048 1,810 500/R
4 x 35/10 PD-VCT-G 35 276/0.41 1.3 10 80/0.41 0.6 3.1 40.5 104 0.0041 2,430 500/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 43
PHELPS DODGE CONDUCTOR TYPE PD-VFF-G
300 V 70oC PVC INSULATED FLAT TYPE, FLEXIBLE TWO CORE WITH GROUND
Application :
In dry room for connection of
portable appliance where
mechanical stresses are low
(e.g. radio sets etc.) not for heating
appliances. The ground conductor
is provided for grounding of those
appliances with electrical supply
system. Phase Conductor

Classification :
Maximum conductor
o
temperature 70 C Circuit voltage PVC Insulation
does not exceed 300 volts.

Reference Standard :
TIS 11-2531 TABLE 16

Construction :
Conductor : Annealed copper, Ground Conductor
bunch stranded
2 2
Sizes 1 mm up to 2.5 mm (Phase)
2 2
Sizes 1 mm up to 1.5 mm (Ground)

Insulation : Heat resistance polyvinyl


chloride
(Any colour as requested)

Phase core Ground core


Allowable Minimum
Nominal Min Number & Thickness Nominal Min Number & Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Max Diameter of Sectional Max Diameter of Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Area of Wire Insulation (approx)
2 2 40°C at 70°C m
mm No. / mm mm mm No. / mm mm mm kg / km
A M - km
2 x 1/1 PD-VFF-G 1 32/0.21 0.8 1 32/0.21 0.6 3.6 x 9.8 16 0.0127 50 100/C
2 x 1.5/1 PD-VFF-G 1.5 30/0.26 0.8 1 32/0.21 0.6 3.9 x 10.5 21 0.0111 60 100/C
2 x 2.5/1.5 PD-VFF-G 2.5 50/0.26 0.8 1.5 30/0.26 0.6 4.8 x 12.5 29 0.0092 90 100/C

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
44 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
PHELPS DODGE CONDUCTOR TYPE PD-VAFF
300 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE, FLAT TYPE, TWO CORE
Application :
For surface or above ceiling wiring
or direct embeded in plaster.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.

Reference Standard :
Conductor
TIS 11-2531 TABLE 17

PVC Insulation

Construction :
Conductor : Annealed copper,
bunch stranded
2 2
Sizes 0.5 mm up to 35 mm

Insulation : Heat resistance polyvinyl


chloride (Gray, and Black colour)
PVC Sheath
Sheath : Heat resistance polyvinyl
chloride (White colour)

Phase core
Allowable Minimum
Nominal Min Number & Thickness Thickness Overall Cable
Ampacities Insulation Standard
PHELPS DODGE Sectional Max Diameter of of Diameter Weight
Free Air Resistance Packing
TYPE LETTER Area of Wire Insulation Sheath (approx)
40°C at 70°C m
mm2 No. / mm mm mm mm kg / km
A M - km
2 x 0.5 PD-VAFF 0.5 16/0.21 0.6 0.9 4.7 x 7.2 8 0.0132 37 100/C
2 x 0.5 PD-VAFF 0.5 28/0.16 0.6 0.9 4.7 x 7.2 8 0.0133 37 100/C
2x1 PD-VAFF 1 32/0.21 0.6 0.9 5.2 x 8.0 13 0.0104 50 100/C
2 x 1.5 PD-VAFF 1.5 30/0.26 0.6 1.2 6.2 x 9.4 17 0.0090 70 100/C
2 x 2.5 PD-VAFF 2.5 50/0.26 0.7 1.2 7.2 x 11.5 23 0.0083 100 100/C
2x4 PD-VAFF 4 56/0.31 0.8 1.2 8.0 x 13.0 30 0.0076 140 100/C
2x6 PD-VAFF 6 84/0.31 0.8 1.2 8.8 x 14.5 40 0.0065 200 100/C
2 x 10 PD-VAFF 10 80/0.41 0.9 1.2 10.5 x 17.5 55 0.0057 300 100/C
2 x 16 PD-VAFF 16 126/0.41 1.0 1.2 12.0 x 20.5 74 0.0047 440 100/C
2 x 25 PD-VAFF 25 196/0.41 1.2 1.4 14.5 x 25.0 97 0.0045 690 500/R
2 x 35 PD-VAFF 35 276/0.41 1.2 1.4 16.0 x 28.0 120 0.0038 900 500/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 45
PHELPS DODGE CONDUCTOR TYPE PD-VAFF
300 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE, FLAT TYPE, THREE CORE
Application :
Building wiring, for installation on
insulator or in raceway, dry and wet
location.

Classification :
Maximum conductor temperature
o
70 C Circuit voltage does not
exceed 300 volts.
Conductor
Reference Standard :
TIS 11-2531 TABLE 17
PVC Insulation

Construction :
Conductor : Annealed copper,
bunch stranded
2 2
Sizes 0.5 mm up to 16 mm

Insulation : Heat resistance


polyvinyl chloride (Gray, Black and PVC Sheath
Red colour)

Sheath : Heat resistance polyvinyl


chloride (White colour)

Number & Allowable Minimum


Nominal Thickness Thickness Overall Cable
Max Diameter Ampacities Insulation Standard
PHELPS DODGE Sectional of of Diameter Weight
of Wire Free Air Resistance Packing
TYPE LETTER Area Insulation Sheath (approx)
2 No. / mm 40°C at 70°C m
mm mm mm mm kg / km
A M - km
3 x 0.5 PD-VAFF 0.5 16/0.21 0.6 0.9 4.7 x 9.6 6.5 0.0132 41 100/C
3 x 0.5 PD-VAFF 0.5 28/0.16 0.6 0.9 4.7 x 9.6 6.5 0.0133 41 100/C
3x1 PD-VAFF 1 32/0.21 0.6 0.9 5.2 x 11.0 11.5 0.0104 55 100/C
3 x 1.5 PD-VAFF 1.5 30/0.26 0.6 1.2 6.2 x 12.5 15 0.0090 77 100/C
3 x 2.5 PD-VAFF 2.5 50/0.26 0.7 1.2 7.2 x 16.0 21 0.0083 110 100/C
3x4 PD-VAFF 4 56/0.31 0.8 1.2 8.0 x 18.5 28 0.0076 154 100/C
3x6 PD-VAFF 6 84/0.31 0.8 1.2 8.8 x 20.5 36 0.0065 220 100/C
3 x 10 PD-VAFF 10 80/0.41 0.9 1.2 10.5 x 25.0 50 0.0057 363 500/R
3 x 16 PD-VAFF 16 126/0.41 1.0 1.4 12.5 x 29.0 66 0.0047 484 500/R

C = Packing in coil
R = Packing in reel

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
46 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
XHHW-2
Application :
general purpose building wire for
installation in air, duct, conduit or
other raceways.

Classification :
600 V rating, maximum conductor
o
temperature 90 C both wet and
dry locations.

Reference Standard :
UL 44 Aluminum Alloy Conductor

Construction :
Conductor : Compact stranded
aluminum alloy 800 series per
ASTM B-801
UL Recognized Cross-Linked Polyethylene
Insulation : UL recognized
cross-linked polyethylene

Approx. Approx.
SIZE Conductor Insulation
Outside Cable Ampacities**
(AWG diameter thickness
Diameter Weight
or kcmil)
mm mm
mm kg/km
6 4.3 1.14 6.8 63 60
4 5.4 1.14 7.9 91 75
2 6.8 1.14 9.3 133 100
1 7.6 1.40 10.7 172 115
1/0 8.5 1.40 11.6 209 135
2/0 9.6 1.40 12.6 253 150
4/0 12.1 1.40 15.2 380 205
250 13.2 1.65 16.8 456 230
300 14.5 1.65 18.1 535 255
350 15.6 1.65 19.2 614 280
400 16.7 1.65 20.3 691 305
500 18.7 1.65 22.3 848 350
600 20.7 2.03 25.2 1039 385
750 23.1 2.03 27.6 1270 435
1000 26.9 2.03 31.4 1655 500

O
**Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30 C per
Table 310-16 of the 1990 National Electrical Code (NFPA 70-1990).

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 47
XHHW , XHHW-2
Application :
General purpose building wire for
installation in air duct, conduit
or other raceways.

Classification :
600 V rating, maximum conductor
o o
temperature 75 C wet or 90 C dry
o
location for XHHW and 90 C both
wet and dry location for XHHW-2
Copper conductor
Reference :
UL 44

Construction :
Conductor : Solid or concentric
stranded (class B) copper per ASTM
UL Recognized Cross-Linked Polyethylene
B-3 or ASTM B-8 and UL 44

Insulation : UL recognized
cross-linked polyethylene

Approx. Approx.
SIZE No./Wire Insulation
Outside Cable Ampacities**
(AWG Size thickness
Diameter Weight Wet Dry
or kcmil) o o
mm mm
75 C 90 C
mm kg/km
14 1/1.63 0.76 3.3 30 15 15
12 1/2.05 0.76 3.7 40 20 20
10 1/2.59 0.76 4.3 60 30 30
14 7/0.62 0.76 3.5 30 15 15
12 7/0.77 0.76 4.0 45 20 20
10 7/0.98 0.76 4.6 65 30 30
8 7/1.24 1.14 6.2 105 50 55
6 7/1.56 1.14 7.2 155 65 75
4 7/1.96 1.14 8.4 235 85 95
2 7/2.47 1.14 9.9 360 115 130
1 19/1.69 1.40 11.5 450 130 150
1/0 19/1.89 1.40 12.5 560 150 170
2/0 19/2.12 1.40 13.7 695 175 195
4/0 19/2.68 1.40 16.5 1080 230 260
250 37/2.09 1.65 18.3 1280 255 290
300 37/2.29 1.65 19.7 1520 285 320
350 37/2.47 1.65 20.9 1765 310 350
400 37/2.64 1.65 22.1 2005 335 380
500 37/2.95 1.65 24.3 2485 380 430
600 61/2.52 2.03 27.1 2995 420 475
750 61/2.82 2.03 29.8 3715 475 535
1000 61/3.25 2.03 33.7 4910 545 615
O
**Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30 C per
Table 310-16 of the 1990 National Electrical Code (NFPA 70-1990).

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
48 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
TYPE THHN - THWN PVC INSULATION WITH NYLON JACKET
14 AWG - 1000 MCM 600V GASOLINE AND OIL, RESISTANT VW-1
Scope :
This specification covers single
conductor cables having polyvinyl
chloride (PVC) insulation with and
overall nylon jacket.

Cables conform to the following


standards :
UL-83 for Thermoplastic Insulated
Wire
UL-758 for Appliance Wiring Materials Solid or stranded bare copper
UL-1063 for Machine Tool Wire
(stranded conductors only)
PVC Insulation
Federal specifications J-C-30B

Application :
- General purpose building wire for
services, feeders and branch
circuits
- Conduit and raceways Nylon jacket
- 1/0 and larger for cable tray use

Product construction conductor :


- Bare annealed copper per ASTM B-3
- Stranded conductors per ASTM B-8 SIZE NO.OF Strand PVC Nylon Approx
Outside
Ampacity Approx
weight
Standard
(AWG Strands Insul Jacket PUT-UP
or 787 OR
Class
thick thick Diameter THWN THHN MTW 100FT
(inches) (inches) (inches) 75 C 90 C 90 C pound
MCM)

Insulation :
solid 0.015 0.004 15 -
- Color coded premium grade flame 14 0.105 15 16 S500/R2500

0.015 0.004
retardant PVC (polyvinyl chloride) 12 soild 0.122 20 20 - 24 S500/R2500

10 soild 0.020 0.004 0.153 30 30 - 37 S500/R2500

Jacket : 14 19 C 0.015 0.004 0.112 15 15 16 17 S500/R2500

- Tough polyamide nylon 12 19 C 0.015 0.004 0.129 20 20 20 25 S500/R2500

- Temperature rating not to exceed : 10 19 C 0.020 0.004 0.162 30 30 30 39 S500/R2500


o
THHN : 90 C dry, and drap, 600V 8 19 C 0.030 0.005 0.214 50 65 40 65 R500/R1000
o
THWN : 75 C dry, wet or in oil, 600 V 6 19 C 0.030 0.005 0.252 65 75 55 98 R500/R1000
o o
MTW : 90 C dry, 80 C in oil, 600 V 4 19 C 0.040 0.006 0.323 85 95 70 157 R500/R1000
o o
AWM : 90 C dry, 80 C in oil, 1000 V 3 19 C 0.040 0.006 0.349 100 110 80 194 R500/R1000
o o
AWM : 105 C dry, 75 C in oil, 600 V 2 19 C 0.040 0.006 0.381 115 130 240 R500/R1000
95

1 19 B 0.050 0.007 0.439 130 150 110 305 R500/R1000


Packaging :
1/0 19 B 0.050 0.007 0.481 150 170 125 379 R500/R1000
- 14 and 12 AWG : 4x500 in a carton
2/0 19 B 0.050 0.007 0.523 175 195 470 R500/R1000
or 2500’ reels 145
19 B 0.050 0.007 0.573 200 225
- 10 AWG : 2x500’ in a carton or 2500’ 3/0 165 584 R500/R1000

reels , and cut to order 4/0 19 B 0.050 0.007 0.628 230 280 185 728 R500/R1000

- 1 AWG and larger : 500’ and 1000’ 250 37 B 0.060 0.008 0.705 255 290 215 868 R500/R1000

reels, and cut to order. 300 37 B 0.060 0.008 0.758 286 320 240 1030 R500/R1000

350 37 B 0.060 0.008 0.809 310 350 280 1193 R500/R1000

400 37 B 0.060 0.008 0.851 335 380 280 1354 R500/R1000

500 37 B 0.060 0.008 0.935 380 430 320 1679 R500/R1000

600 61 B 0.070 0.009 1.031 420 475 355 2023 R500/R1000

750 61 B 0.070 0.009 1.136 475 535 2508 R500/R1000


400
1000 61 B 0.070 0.009 1.289 545 615 3242 -
455

Color: Black, white, red, green, yellow, blue, orange, gray, purple, pink, tan

Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008 49
ALL WIRE & CABLES MANUFACTURED BY PHELPS DODGE INTERNATIONAL (THAILAND) LIMITED.
ARE QUALITY TESTED & CONFORM WITH THE FOLLOWING STANDARDS:
AEIC ASSOCIATION OF EDISON ILLUMINATING COMPANIES
AS/NZS AUSTRALIAN/ NEW ZEALAND STANDARD
ANS/EIA AMERICAN NATIONAL STANDARD
ELECTRONIC INDUSTRIES ASSOCIATION
ANSI/IEEE AMERICAN NATIONAL STANDARD
THE INSTITURE OF ELECTRICAL AND ELECTRONICS ENGINEERS
ANSI/TIA/EIA AMERICAN NATIONAL STANDARD
TELECOMMUNICATIONS ASSOCIATION
ELECTRONIC INDUSTRIES ASSOCIATION
AS AUSTRALIAN STANDARD
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
BELLCORE BELLCORE
BS BRITISH STANDARD
DIN DEUTSCHER INSTRTUT FOR NORMUNG E V. BERLIN
EGAT ELECTRICITY GENERATING AUTHORITY OF THAILAND
FAA FEDERAL AVIATION ADMINISTRATION
HK HONG KONG TELECOMMUNICATIONS
ICEA INSULATED CABLES ENGINEERS ASSOCIATION
ANSI/ICEA AMERICAN NATIONAL STANDARD
INSULATED CABLES ENGINEERS ASSOCIATION
NEMA/ICEA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
INSULATED CABLES ENGINEERS ASSOCIATION
IPCEA INSULATED POWER CABLES ENGINEERS ASSOCIATION
IEC INTERNATIONAL ELECTRICAL COMMISSION
ICEE THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, INC.
ISO INTERNATIONAL ORGANIZATION FOR STANDARDIZATION
JIS JAPANESE INDUSTRIAL STANDARD
MEA METROPOLITAN ELECTRICITY AUTHORITY
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
PEA PROVINCIAL ELECTRICITY AUTHORITY
REA RURAL ELECTRIFICATION ADMINISTRATION
SABS SOUTH AFRICAN STANDARD
TIS THAI INDUSTRIAL STANDARD
TOT TOT PUBLIC COMPANY LIMITED
UL UNDERWRITERS LABORATORIES
Phelps Dodge International (Thailand) Limited Building Wires and Interior Wiring
50 Maneeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330
Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Revision 2 : July 16, 2008
Address and Contact Point
Sales and Executive Office:
518/5 Maneeya Center Bldg., 16 Fl. Ploenchit Rd.,
Lumpinee, Pathumwan, Bangkok 10330 Thailand
Tel : (662) 680 5800
Fax : (662) 680 5896, 680 5898
Website: www.pdic.com

Bangplee Factory :
159 Moo 10, Soi Watraburana, Theparak., Rd., Km. 17
Bangpla, Bangplee, Samut Prakarn 10540 Thailand.
Tel : (662) 769 2400
Fax : (662) 769 2440

Rayong Factory:
9/9 Moo4, Tambol Nikompattana,
Ampur Nikompattana, Rayong 21180 Thailand
Tel : (66) 038 877 155 (Auto 10 Lines)
Fax : (66) 038 877 166

You might also like