You are on page 1of 10

Electronic ballast

GE introduced its electronic


ballast range in 2003.
The device is used for
starting and operating
discharge lamps.
GE’s ballast line includes CMH, CFL and LFL electronic ballasts. They are
energy efficient alternatives to electromagnetic ballasts and ideally
suited to operate GE lamps. Besides the small compact size for all types,
ballasts ensure flicker free light throughout the lifetime of the lamp.
The combination of GE lamps and ballasts meets requirements for long
product life and superior performance.

180 spectrum – THE GE LIGHTING LAMP CATALOGUE


Electronic ballast

Content
Ceramic Metal Halide Ballasts 183
Linear Fluorescent Ballasts 185
Compact Fluorescent Ballast 189

spectrum – THE GE LIGHTING LAMP CATALOGUE 181


Electronic ballast
CMH Ballast

Ceramic Metal Halide Ballasts


GE Lighting’s CMH lamp and ballast system meets the demand for crisp white light. Coupling ConstantColorTM CMH lamps
with dedicated GE electronic ballasts ensures further enhanced performance throughout a long lamp life. All CMH ballasts
offered by GE are electronic, giving important advantages over conventional electromagnetic circuits:

• Major savings on electricity • Flicker-free light • Long lamp life • Light weight and compact size • Simplified wiring

CMH Mini CMH Single Ended CMH PAR 30

CMH Double Ended CMH Elliptical Diffuse CMH Tubular Clear

CMH Supermini CMH Elliptical Clear MR16

Ballasts are available in 20W, 35W, 70W and 150W ceramic metal halide lamps and quartz metal halide lamps. There
are two mounting options for all wattages:
• Integral with open terminals – designed for embodiment into the luminaire housing
• Remote with covered terminal and cable strain relief – for location outside the luminaire.

182 spectrum – THE GE LIGHTING LAMP CATALOGUE


Electronic ballast
CMH Ballast
CMH Ballasts General Information
Watts Volts Description Mounting Weight Pack Product
Qty Code

20 220-240 BLS/E/20W/CMH Integral 190 g 12 13032


20 220-240 BLS/E/20W/CMH/R Remote 230 g 12 13034
35 220-240 BLS/E/35W/CMH Integral 215 g 12 13035
35 220-240 BLS/E/35W/CMH/R Remote 230 g 12 13036
70 220-240 BLS/E/70W/CMH Integral 300 g 12 13040
70 220-240 BLS/E/70W/CMH/R Remote 310 g 12 13047
150 220-240 BLS/E/150W/CMH Integral 430 g 12 13050
150 220-240 BLS/E/150W/CMH/R Remote 445 g 12 13053

Technical Data
System System Lamp Lamp Mains Max. Max Max
Power Efficacy lm Power Efficacy Current Cable Cap. Cable Length Tc

W lm/W lm W lm/W A pF m °C

BLS/E/20W/CMH 23,5 72 1700 20 85 0.10 1000 10 75


BLS/E/20W/CMH/R 23,5 72 1700 20 85 0.10 1000 10 75
BLS/E/35W/CMH 43 79 3400 39 87 0.18 3000 25 75
BLS/E/35W/CMH/R 43 79 3400 39 87 0.18 3000 25 75
BLS/E/70W/CMH 78 80 6200 72 86 0.33 3000 25 75
BLS/E/70W/CMH/R 78 80 6200 72 86 0.33 3000 25 75
BLS/E/150W/CMH 159 88 14000 146 96 0.69 3000 25 80
BLS/E/150W/CMH/R 159 88 14000 146 96 0.69 3000 25 80

Ballast Selector for ConstantColorTM CMH Lamps


ConstantColorTM CMH lamp GE Electronic Ballast

Watts Lamp Prod. Integral Prod. Remote Prod.


Description Code Mounting Code Mounting Code
Single Ended Mini
20 CMH20/TC/UVC/U/830/G8.5 92079 BLS/E/20W/CMH 13032 BLS/E/20W/CMH/R 13034
35 CMH35/TC/UVC/U/830/G8.5 38697 BLS/E/35W/CMH 13035 BLS/E/35W/CMH/R 13036
70 CMH70/TC/UVC/U/830/G8.5 38700 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047

Single Ended
35 CMH35/T/UVC/U/830/G12 38696 BLS/E/35W/CMH 13035 BLS/E/35W/CMH/R 13036
70 CMH70/T/UVC/U/830/G12 36844 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047
70 CMH70/T/UVC/U/942/G12 38701 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047
150 CMH150/T/UVC/U/830/G12 36863 BLS/E/150W/CMH 13050 BLS/E/150W/CMH/R 13053
150 CMH150/T/UVC/U/942/G12 38694 BLS/E/150W/CMH 13050 BLS/E/150W/CMH/R 13053

Double Ended
70 CMH70/TD/UVC/830/RX7s 36910 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047
70 CMH70/TD/UVC/942/RX7s 38698 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047
150 CMH150/TD/UVC/830/RX7s 36912 BLS/E/150W/CMH 13050 BLS/E/150W/CMH/R 13053
150 CMH150/TD/UVC/942/RX7s 38692 BLS/E/150W/CMH 13050 BLS/E/150W/CMH/R 13053

PAR 20
35 CMH35/PAR20/UVC/830/E27/SP 41883 BLS/E/35W/CMH 13035 BLS/E/35W/CMH/R 13036
35 CMH35/PAR20/UVC/830/E27/FL 41884 BLS/E/35W/CMH 13035 BLS/E/35W/CMH/R 13036

PAR 30
35 CMH35/PAR30/UVC/830/E27/SP 41886 BLS/E/35W/CMH 13035 BLS/E/35W/CMH/R 13036
35 CMH35/PAR30/UVC/830/E27/FL 41887 BLS/E/35W/CMH 13035 BLS/E/35W/CMH/R 13036
70 CMH70/PAR30/UVC/830/E27/SP 41621 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047
70 CMH70/PAR30/UVC/830/E27/FL 41620 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047

Elliptical Clear
70 CMH70/E/UVC/U/830/E27/C 46189 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047

Elliptical Diffuse
70 CMH70/E/UVC/U/830/E27/D 46187 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047

Tubular Clear
70 CMH70/TT/UVC/830/E27 38752 BLS/E/70W/CMH 13040 BLS/E/70W/CMH/R 13047
150 CMH150/TT/UVC/830/E40 38749 BLS/E/150W/CMH 13050 BLS/E/150W/CMH/R 13053

Ballast Product BLS/E/20W/CMH/R Remote Mount (optional)


Electronic
Nominal Lamp Power SuitableLamp Group

spectrum – THE GE LIGHTING LAMP CATALOGUE 183


Electronic ballast
LFL Ballast

Linear Fluorescent Ballasts


From 14W to 80W, GE cove rs the full T5 range for non-dimming applications. No more concerns about compatibility and reliability.
GE ’s system approach delive rs peace of mind.

• Reliable warm start and maximised lamp life.


• Multiwatt ballasts for both High Efficiency and High Output lamps to simplify inventory
• Soft and reliable start and maximised lamp lifetime
• Practically unlimited on-off switching
• Minimised end-darkening
• Delivers significant cost savings

184 spectrum – THE GE LIGHTING LAMP CATALOGUE


Electronic ballast
LFL Ballast
T5 Ballast
Nr of Supply Lamp type Total System System Input Power Ambient Max Tc EEI Pack Product
Lamps Volt V W Lumens Im Power W Efficacy Im/W Current A Factor Temperature ˚C ˚C Class Qty Code

1 220-240 14 1350 17 79 0.08 > 0.98 -15...+50 70 A2 20 13232


1 220-240 21 2100 24 88 0.11 > 0.98 -15...+50 70 A2 20 13232
1 220-240 28 2900 32 91 0.15 > 0.98 -15...+50 70 A2 20 13232
1 220-240 35 3650 40 91 0.18 > 0.98 -15...+50 70 A2 20 13232
1 220-240 14 1350 18 75 0.09 > 0.95 -20...+60 80 A2 20 13240
1 220-240 24 2000 26 77 0.10 > 0.97 -20...+60 80 A2 20 13240
1 220-240 35 3650 39 94 0.19 > 0.98 -20...+60 80 A2 20 13240
1 220-240 49 4900 54 91 0.25 > 0.98 -20...+60 80 A2 20 13240
1 220-240 21 2100 25 84 0.11 > 0.99 -20...+50 80 A2 20 13241
1 220-240 28 2900 34 85 0.15 > 0.99 -20...+50 80 A2 20 13241
1 220-240 39 3500 41 85 0.17 > 0.99 -20...+50 80 A2 20 13241
1 220-240 54 5000 60 83 0.26 > 0.99 -20...+50 80 A2 20 13241
1 220-240 80 7000 88 80 0.38 > 0.99 -15...+50 75 A2 20 16863
2 220-240 14 2700 32 84 0.15 > 0.99 -15...+50 70 A2 20 13234
2 220-240 21 4200 47 89 0.21 > 0.99 -15...+50 70 A2 20 13234
2 220-240 28 5800 62 94 0.27 > 0.99 -15...+50 70 A2 20 13234
2 220-240 35 7300 77 95 0.34 > 0.99 -15...+50 70 A2 20 13234
2 220-240 24 4000 50 80 0.22 > 0.99 -15...+50 70 A2 20 16864
2 220-240 39 7000 86 81 0.37 > 0.99 -20...+50 75 A2 20 16865
2 220-240 49 9800 106 92 0.46 > 0.99 -20...+50 75 A2 20 13242
2 220-240 54 10000 118 85 0.52 > 0.99 -20...+50 75 A2 20 13243
2 220-240 80 14000 175 80 0.70 > 0.99 -20...+50 85 A2 20 16866
3 220-240 24 6000 76 79 0.33 > 0.99 -15...+50 70 A2 20 16867
3 220-240 14 4050 47 86 0.21 > 0.97 -15...+50 70 A2 20 13237
4 220-240 14 5400 62 87 0.27 > 0.97 -15...+50 70 A2 20 13237

Ballast Product BLS/E/2x14–21–28-35W/T5 Lamp Group


Electronic
Number of Lamps Nominal Lamp Wattage

Allowed mains voltage: 198...264 V All available ballasts are approved by VDE and comply
Mains frequency: 50 / 60 Hz with the relevant parts of the following standards.
Earth leakage current < 0.5 mA EN 60929, EN 61347-1, EN 61347-2-3
Preheat time: < 2 sec EN 61000-3-2, EN 61547, EN 55015

spectrum – THE GE LIGHTING LAMP CATALOGUE 185


Electronic ballast
LFL Ballast
Ballast Selector for StarcoatTM T5 Lamps
GE Starcoat™ T5 lamp Lamp Product Code by Colour

Watts Product Pack /827 /830 /835 /840 /865


Description Qty
High Efficiency
14 F14W/T5 30 90230 90239 90246 90247 90244
40 39965 39964 39961 39973 90222
21 F21W/T5 30 90245 90248 90249 90250 90251
40 39975 39976 39977 39978 39979
28 F28W/T5 30 90252 90253 90254 90255 90256
40 39980 39982 39983 39984 39985
35 F35W/T5 30 90257 90258 90259 90260 90261
40 39986 39989 39990 39991 39992

High Output
24 F24W/T5 30 90262 90263 90264 90265 90266
40 39994 39998 90196 90197 90198
39 F39W/T5 30 90267 90268 90269 90270 90271
40 90200 90201 90202 90203 90204
49 F49W/T5 30 90277 90278 90279 90280 90281
40 90220 90219 90221 90223 90224
54 F54W/T5 30 90272 90273 90274 90275 90276
40 90205 90232 90206 90209 90211
80 F80W/T5 30 90282 90283 90284 90285 90286
40 90225 90226 90227 90228 90229

GE Electronic T5 Ballast
with 1 lamp with 2 lamp with 3 lamp with 4 lamp
Watts Product Product Product Product Product Product Product Product
Description Code Description Code Description Code Description Code

High Efficiency
14 BLS/E/1x14-21-28-35W/T5 13232 BLS/E/2x14-21-28-35W/T5 13234 BLS/E/3-4x14W/T5 13237 BLS/E/3-4x14W/T5 13237
BLS/E/1x14-24-35-49W/T5 13240
21 BLS/E/1x14-21-28-35W/T5 13232 BLS/E/2x14-21-28-35W/T5 13234
BLS/E/1x21-28-39-54W/T5 13241
28 BLS/E/1x14-21-28-35W/T5 13232 BLS/E/2x14-21-28-35W/T5 13234
BLS/E/1x21-28-39-54W/T5 13241
35 BLS/E/1x14-21-28-35W/T5 13232 BLS/E/2x14-21-28-35W/T5 13234
BLS/E/1x14-24-35-49W/T5 13240

High Output
27 BLS/E/1x14-24-35-49W/T5 13240 BLS/E/2x24W/T5 16864 BLS/E/3x24W/T5 16867
39 BLS/E/1x21-28-39-54W/T5 13241 BLS/E/2x39W/T5 16865
49 BLS/E/1x14-24-35-49W/T5 13240 BLS/E/2x49W/T5 13242
54 BLS/E/1x21-28-39-54W/T5 13241 BLS/E/2x54W/T5 13243
80 BLS/E/1x80W/T5 16863 BLS/E/2x80W/T5 16866

186 spectrum – THE GE LIGHTING LAMP CATALOGUE


Electronic ballast
LFL Ballast

T8 Ballasts
Range of GE electronic ballasts have been introduced to complement the Polylux XLR™ linear fluores-
cent range.

Features:
• Full compatibility with T8 linear fluorescent lamps
• Non-dimmable range
• Warm start circuit preheating
• Maximized lamp life
• Minimized end-blackening

Low system losses


• Immune to mains voltage variations
• With built in shutdown circuit to manage lamp failure
• Constant light output for full input voltage range
• 100% tested and burnt-in

Lamp Product Nr. of Total System System Input PF Ambient Max Tc Pack Product
type Description lamps lumens* Power Efficiacy current Temp. °C Qty Code
W lm W lm/W A °C

T8 Ballast – 220-240V A2 EEI Class


18 BLS/E/1x18W/T8 1 1350 18 75 0.08 > 0.99 -15...+50 65 20 19862
18 BLS/E/2x18W/T8 2 2700 35 77 0.16 > 0.99 -15...+50 65 20 19867
18 BLS/E/3x18W/T8 3 4050 53 76 0.23 > 0.99 -15...+50 70 20 19869
18 BLS/E/4x18W/T8 4 5400 74 73 0.32 > 0.99 -15...+50 70 20 19870
36 BLS/E/1x36W/T8 1 3350 35 96 0.16 > 0.99 -15...+50 65 20 19874
36 BLS/E/2x36W/T8 2 6700 71 94 0.31 > 0.99 -15...+50 75 20 19875
58 BLS/E/1x58W/T8 1 5200 55 95 0.25 > 0.99 -15...+50 70 20 19881
58 BLS/E/2x58W/T8 2 10400 110 95 0.49 > 0.99 -15...+50 75 20 19883
70 BLS/E/1x70W/T8 1 6300 66 95 0.28 > 0.99 -15...+50 65 20 22578
70 BLS/E/2x70W/T8 2 12600 133 95 0.57 > 0.99 -15...+50 75 20 22580

spectrum – THE GE LIGHTING LAMP CATALOGUE 187


Electronic ballast
CFL Ballast

Compact Fluorescent Ballast


An electronic ballast to operate GE’s unique high output compact fluorescent lamps: the BiaxTM Q/E 57W and 70W. A single
ballast is suitable for both lamp wattages, enabling more flexibility in design and manufacturing.
The lamps allow reaching high illumination levels with less luminaries compared to many CFL downlights.

• Up to 5200 lumens
• perfect alternatives to HID lighting
• rapid warm-up
• excellent quality of light at a stable lumen maintenance
• instant restrike
• provide flicker-free white light

Taking all advantages of fluorescent lighting, BiaxTM Q/E lamps with GE electronic ballasts can be used in a wide range of
applications such as shopping centres, supermarkets, sports halls, public buildings, airports and industrial sites.

188 spectrum – THE GE LIGHTING LAMP CATALOGUE


Electronic ballast
CFL Ballast
Biax Q/E Electronic Ballast
Nr of Lamp Volts Product Initial Lamp Lamp System System Colour Input Pack Product
Lamps Watts Description Lumens Power Efficacy Power Efficacy Rendering Current Qty Code
W lm W lm/W W lm/W Ra A

1 57 220-240 BLS/E/1x57-70W/QBX 4300 56.0 77 60.5 71 82 0.28…0.25 12 13248


1 70 220-240 BLS/E/1x57-70W/QBX 5200 70.0 74 75.5 69 82 0.35…0.31 12 13248

Lamp Selection Guide


Nominal Colour Product Overal Cap Average Pack Product
Watts Temperature Description Lengh Type Life Qty Code
[K] [mm] [h]

57 2700 F57QBX/827/A/4P/EOL 178 GX24q-5 12000 10 48861


57 3000 F57QBX/830/A/4P/EOL 178 GX24q-5 12000 10 48862
57 3500 F57QBX/835/A/4P/EOL 178 GX24q-5 12000 10 48863
57 4000 F57QBX/840/A/4P/EOL 178 GX24q-5 12000 10 48864
57 5000 F57QBX/850/A/4P/EOL 178 GX24q-5 12000 10 93404
70 2700 F70QBX/827/A/4P/EOL 208 GX24q-6 12000 10 48865
70 3000 F70QBX/830/A/4P/EOL 208 GX24q-6 12000 10 48866
70 3500 F70QBX/835/A/4P/EOL 208 GX24q-6 12000 10 48867
70 4000 F70QBX/840/A/4P/EOL 208 GX24q-6 12000 10 48868
70 5000 F70QBX/850/A/4P/EOL 208 GX24q-6 12000 10 93406

Compliance
Ballast is approved by VDE and complies with the relevant parts of the following standards
EN 60929, EN 61347-1, EN 61347-2-3. EN 61000-3-2, EN 61547, EN 55015

Ballast Identification

Ballast Product BLS/E/1x57–70W/QBX Lamp Group


Electronic
Number of Lamps Nominal Lamp Wattage

Biax™ Q/E 57W Biax™ Q/E 70W

spectrum – THE GE LIGHTING LAMP CATALOGUE 189

You might also like