Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.1 Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.2 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.3 Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.4 Grouped Task Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.1 Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.2 Site Specific Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.3 External Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 Scheduling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 Telecom/Supervision Outage and Operating Impact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5.1 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5.2 Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5.3 Applicable Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Before Going Onsite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.1 Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.2 Required Knowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 Scenario Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.1 Initial Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.2 Create Backup PRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.3 Modify Logical Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.4 Start Traffic on Extended Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.5 Call Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.6 Create Adjacencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.7 Final Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 Reverse Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4.1 Lock Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4.2 Restore Logical Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4.3 Unlock Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4.4 Call Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4.5 Final Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 9 10 10 10 10 11 12 12 12 12 13 15 16 16 16 16 17 18 19 19 19 20 20 20 21 28 28 29 29 30 30 30 31 31 31
3 / 32
Contents
4 / 32
Preface
Preface
Purpose
This document describes how to create extended cells on an 9100 BTS. This method applies to BSS and OMC-R at technical release B10.
Whats New
In Edition 05
Improve Presentation (Section 1.1) due to 3 extended cells allowance on BTS and Multiple CCCH support.
In Edition 04
Update with the new equipment naming.
In Edition 03
Restriction 3BKA20FBR230654 added in Create Adjacencies (Section 2.3.6).
In Edition 02
Delivered in release. Update in Applicable Documents (Section 1.5.3) First official release of the document for B10 MR2.
In Edition 01
Overall document quality was improved following an editorial review. The following sections were updated: Create Extended Inner (Section 2.3.3.2) Create Extended Outer (Section 2.3.3.3). Start Traffic on Extended Cell (Section 2.3.4) First official release of the document for B10.
Audience
5 / 32
Preface
6 / 32
Preface
Assumed Knowledge
You must have a basic understanding of the following: Planning: Network architecture and reshuffling principles Scheduling. Implementation: Alcatel-Lucent operations and maintenance concepts for the BSS 9153 OMC-R operation Equipment (BSC, BTS, MFS) hardware configurations Windows environment.
7 / 32
Preface
8 / 32
1 Overview
1 Overview
This Overview gives information needed by project managers and foremen, for presentation to the customer and for site planning.
9 / 32
1 Overview
1.1 Presentation
This scenario describes how to create and configure extended cells. The maximum range defined in GSM for the access to a cell is 35 km. The goal of an extended cell is to increase the maximum distance between the BTS and the MS, without changing the Air interface, to 70 km. Two different cells are combined in order to create the extended cell. One cell (Extended Inner) covers the range from 0 to 35 km and another cell (Extended Outer) covers the range from 35 to 70 km. According to the engineering rules: For 9100 BTS, the extended cell allows for several non -hopping TRXs Extended cells are supported only on 9100 BTS with SUMA LCS is supported on extended cells GPRS is supported on extended cells Both GSM and DCS frequency bands are allowed for extended cells 3 extended cells per BTS are allowed: 3 times (inner + outer) Multiple CCCH is not supported in Extended Cell.
1.1.1 Cases
The following cases apply: C1: Create Extended Cell C1.1: Create Extended Inner Cell C1.2: Create Extended Outer Cell. C2: Modify Single Cell to Extended Cell C2.1: Modify Single Cell to Extended Inner Cell C2.2: Modify Single Cell to Extended Outer Cell.
Note:
You can combine different cases to create the required configuration: To create an complete Extended Cell, use a combination of C1.1and C1.2 If one cell is already created, use a combination of C1.1 and C2.2 or C1.2 and C2.1 If both cells must be modified, use a combination of C2.1 andC2.2.
1.1.2 Options
O1: GPRS on extended cell can apply.
1.1.3 Restrictions
None.
10 / 32
1 Overview
MSC
OMCR
Initial Checks
BTS
Call Tests
Create Adjancencies
Final Checks
11 / 32
1 Overview
1.2 Preparation
1.2.1 Prerequisites
The following prerequisites apply: 9100 is installed and qualified Two sectors are needed: one for Extended Outer and one for Extended Inner cell Extended Outer Cell and Extended Inner Cell must have the same Frequency Range Enough resources (in terms of Abis timeslots and TCU) The antenna(e) are verified and functional.
12 / 32
1 Overview
1.3 Scheduling
Note:
Time based on technical constraints In the following table, the number of resources shown does not take into account individual customer or safety requirements. Grouped Task Initial Checks OMC-R 1 ope. 15 min. Create Backup PRC 1 ope. 6 min. Create Working PRC 1 ope. 3 min. C2: + 11 min./ cell Create Extended Inner 1 ope. C1.1 13.5 min. C2.1 1 min. C2.2 1 min. Create Extended Outer 1 ope. C1.2 11.5 min. Check working PRC 1 ope. 1 min. Start Traffic 1 ope. 3 min. + 5 min./ cell C2: +4 min./ cell Call Tests 1 ope. 10min./ cell Create Adjacencies 1 ope. 9min./ cell 9 min./ cell C2: +4 min./ cell 10 min./ cell 31 min. + 5 min./ cell 1 min. C2.1 +1 min. C2.2 1 min. C1.2 11.5 min. C2: + 11 min./cell C1.1 13.5 min. 3 min. 6 min. Time/Task 15 min.
13 / 32
1 Overview
Time/Task 15 min.
Total time:
43 min. + 24 min./ cell C1.1 +13.5 min. C1.2 +11.5 min. C2 +1 min. + 15 min./ cell
ope.
: OMC-R Operator
14 / 32
1 Overview
Tel. Out -
GPRS Out -
Tel. Red -
Sup.Out -
Impacts... -
1 min. 30 sec.
TOTAL
1 min. 30 sec.
15 / 32
1 Overview
1.5 Resources
1.5.1 Tools
The following tables describe the necessary hardware tools, software tools, and forms.
1.5.1.3 Forms
None.
1.5.2 Supplies
None.
16 / 32
2 Scenario
2 Scenario
This Scenario presents all checks needed before beginning the scenario, and all detailed tasks to be performed on each site.
17 / 32
2 Scenario
18 / 32
2 Scenario
19 / 32
2 Scenario
Note:
Case-specific tasks are marked with C1, C2 in the Note column. Detailed tasks that do not have C1, C2 in the Note column are common to all cases and must always be performed.
This task creates a backup PRC for the Reverse Procedure (Section 2.4). OMC-R OMC-R 2 min. 1 min. None. None.
Copy impacted cell(s) to Backup PRC; the cells belonging to the impacted BTS. Check PRC (check all, without forcing the Cell Administrative State). If the check produces error messages, correct the configuration as required and re-attempt the check. Continue corrections and checks until no error messages appear. Close PRC (Backup PRC). OMC-R 1 min. None. OMC-R 1 min. None.
20 / 32
2 Scenario
OMC-R
1 min.
None.
C2
OMC-R OMC-R
2 min. 2 min./cell
None. None.
Note:Copy all the cells of the BTS, including the ones which will become Extended Inner or Extended Outer, into the PRC. C2 If the Hopping Type on the cell which will become Extended Inner or Extended Outer is different than NH, use Configure Logical Channels. OMC-R 1 min./cell None.
Note:The TRX channel hopping law will be removed. OMC-R 1 min./cell None
C2
Note:In the "Frequencies View" window, put NH for the Hopping Type and Altern. Hop. Type fields. C2 Change Cell Type to Extended Inner for the cell which will become Extended Inner, or to Extended Outer for the cell which will become Extended Outer. If the Extended Inner or Outer Cell has GPRS, use Set Cell Telecom Parameters to check and modify (if necessary) the GPRS parameters as follows: MAX_PDCH, MAX_PDCH_HIGH_LOAD and MIN_PDCH must have even values NB_TS_MPDCH must be set to 0 when the cell type is Extended Inner / Outer MAX_EGPRS_MCS is MCS4 for Extended Outer and MCS9 is for Extended Inner EN_NACC, EN_PSI_STATUS and EN_STREAMING are disabled. OMC-R 1 min./cell None
C2 O1
OMC-R
2 min./ cell
None.
Note:If LCS was activated on the cell, and the operator wants to keep it activated, do not set MAX_PDCH=0 on these cells.
21 / 32
2 Scenario
22 / 32
2 Scenario
Note C1.1 O1
Task Description To configure GPRS on a cell: Set the Routing Area Code Set the Routing Area Color MAX_PDCH, MAX_PDCH_HIGH_LOAD and MIN_PDCH must have even values NB_TS_MPDCH must be set to 0 when the cell type is Extended Inner / Outer MAX_EGPRS_MCS is MCS9 EN_NACC, EN_PSI_STATUS and EN_STREAMING are disabled When GPRS is created on the cell, you can also modify the following parameters: Min_PDCH NB_TS_MPDCH Max_Pdch_High_Load En_fast_initial_GPRS_access Ps_Pref_Bcch_Trx max_GPRS_Cs max _EGPRS_Mcs En_EGPRS If LCS with AGPS is activated, you can also modify the EN_CONV_GPS, EN_MS_Assisted_AGPS and EN_MS_BASED_AGPS parameters. To have EGPRS on the extended cell: Both inner and outer cells must have EGPRS declared (the EN-EGPRS parameter is set to Enable) All TRXs from inner and outer cells must support EDGE (all TRXs are TRAs).
To do 2 min.
Outage None.
To have GPRS on the cell, Trx_Pref_Mark must be 0 for at least one TRX. To modify it for a block of TRX, use the Java Script Set/Update Circuit/Packet Mark Configuration Using Script. To modify only one cell, use the edit cell command (see Set Cell Telecom Parameters) If En_fast_initial_GPRS_access is set to Enable, respect the following rule: Min_PDCH >= En_fast_initial_GPRS_access + NB_TS_MPDCH.
C1.1
OMC-R
0.5 min.
None.
Note:Use only Non Hopping for the Hopping Type. C1.1 Create TRX. OMC-R 0.5 min./TRX 1 min. None.
C1.1
OMC-R
None.
23 / 32
2 Scenario
Note C1.1
Site OMC-R
Outage None.
C1.1
OMC-R
None.
Note:Select a non-null value. C1.1 Click on [ Apply and check ] in the "Edit Cell" window to save cell modifications in the Working PRC. Wait for the No error or warning message and click on [ Ok ]. If the check produces error messages, correct the configuration as required and re-attempt the check. Continue corrections and checks until no error messages occur. C1.1 Change Cell Type of the single cell to Extended Inner. Use Change Mate Cell to set Mate Cell parameters for the Extended Inner Cell. OMC-R 1 min. None OMC-R 0.5 min. None.
C2.2
OMC-R
1 min.
None
Mate cells must have the same LAC and the same BSIC. C1.1 Map Cell to a BTS Sector. OMC-R 1 min. None.
24 / 32
2 Scenario
Note:Extended Inner and Extended Outer mate cells must have the same LAC and the same BSIC Select ExtendedOuter for the Cell Type parameter. C1.2 Use Set Cell Telecom Parameters. OMC-R 2 min. None.
Note:Set EN_PBGT_FILTERING to Disabled To have LCS on the cell, set MAX_PDCH>0 If the Extended Inner / Outer cells are PS capable, they must have the same value for the ACCESS_BURST_TYPE parameter.
25 / 32
2 Scenario
Note C1.2 O1
Task Description To configure GPRS on a cell: Set the Routing Area Code Set the Routing Area Color MAX_PDCH, MAX_PDCH_HIGH_LOAD and MIN_PDCH must have even values NB_TS_MPDCH must be set to 0 when the cell type is Extended Inner / Outer MAX_EGPRS_MCS is MCS4 for Extended Outer EN_NACC, EN_PSI_STATUS and EN_STREAMING are disabled. When GPRS is created on the cell, you can also modify the following parameters: Min_PDCH NB_TS_MPDCH Max_Pdch_High_Load En_fast_initial_GPRS_access Ps_Pref_Bcch_Trx max_GPRS_Cs max _EGPRS_Mcs En_EGPRS If LCS with AGPS is activated, you can also modify the EN_CONV_GPS, EN_MS_Assisted_AGPS and EN_MS_BASED_AGPS parameters. To have EGPRS on the extended cell: Both inner and outer cells must have EGPRS declared (the EN-EGPRS parameter is set to Enable) All TRXs from inner and outer cells must support EDGE (all TRXs are TRAs).
To do 2 min.
Outage None
To have GPRS on the cell, Trx_Pref_Mark must be 0 for at least one TRX. To modify it for a block of TRX, use the Java Script Set / Update Circuit / Packet Mark Configuration Using Script. To modify only one cell, use the edit cell command (see Set Cell Telecom Parameters) If En_fast_initial_GPRS_access is set to Enable, respect the following rule: Min_PDCH >= En_fast_initial_GPRS_access + NB_TS_MPDCH.
26 / 32
2 Scenario
Note C1.2
Site OMC-R
To do 0.5 min.
Outage None.
Note:Use only Non Hopping for the Hopping Type. C1.2 C1.2 C1.2 C1.2 C1.2 Create TRX. Configure Logical Channels. Configure TRX. Specify TRX Preference. Click on [ Apply and check ] in the "Edit Cell" window to save cell modifications in the Working PRC. Wait for the No error or warning message and click on [ Ok ]. If the check produces error messages, correct the configuration as required and re-attempt the check. Continue corrections and checks until no error messages occur. C1.2 Map Cell to a BTS Sector. OMC-R 1 min. None. OMC-R OMC-R OMC-R OMC-R OMC-R 0.5 min./ TRX 1 min. 0.5 min./TRX 0.5 min./ TRX 0.5 min. None. None. None. None. None.
Note:For C2: For the cell which was modified from single to Extended Inner or Outer, ignore the following error message:
Cell should be locked.
27 / 32
2 Scenario
Note:Shut down the cell which was modified from single to Extended Inner or Outer. Activate PRC (Working PRC) in queued mode, with cell clean-up, without forcing the Cell Administrative State. Display Pending Activations List to see when the activation is finished. OMC-R 5 min./ cell Outage 1
The activation time depends on the number of cells activated. During the activation, supervision outage: 1 min. 30 sec. OMC-R OMC-R OMC-R 1 min. 1 min. 2 min. Outage 1 Outage 1 Outage 1
Close PRC (Working PRC). Perform Bar Cell for all extended inner cells. Use Unlock Cell for all the cells that were shut down and for the new cells. If GPRS is locked Unlock GPRS Traffic on Cell for the extended cell.
O1
OMC-R
2 min.
END1
This task must be done in parallel with the next task. Unlock Cell from Call Test is not necessary here. CHECK Display USD Detailed Cell Information. Check that calls are performed on the new cells. If calls fail, go to the Reverse Procedure (Section 2.4). O1 Perform GPRS calls on the extended cell (Inner / Outer). Check in the DTC report that each GPRS call is successful and print the DTC-report. OMC-R 15 min. None. OMC-R 5 min./ cell None.
28 / 32
2 Scenario
Note -
Site OMC-R
Outage None.
Note:Create adjacencies between the Extended Inner and Extended Outer Cell. For each cell on the same OMC-R that must be adjacent to the new cells, Modify Adjacency to include the new cells. For each cell on the neighboring OMC-Rs that must be adjacent to the new cells, Modify Adjacency on neighboring OMC-Rs to include the new cells. OMC-R 2 min./ cell None.
neighbor OMC-R
2 min./ cell
None.
29 / 32
2 Scenario
Note:Copy Extended Inner and Extended Outer cells. C1 Use Delete OMC Cell from PRC to delete Extended Outer and Extended Inner cells. Use the Check All option in Check PRC (Delete_cell PRC) (without forcing the Cell Administrative State) to check the parameters, hardware, and telecom impact of your PRC. Activate PRC (Working PRC) in queued mode, with cell clean-up, without forcing the Cell Administrative State. Display Pending Activations List to see when the activation is finished. OMC-R 1 min. -
C1
OMC-R
1 min.
C1
OMC-R
5 min./ cell
The activation time depends on the number of cells activated. During the activation, supervision outage: 1 min. 30 sec. OMC-R OMC-R OMC-R 1 min. 1 min. 5 min./ cell -
C1 -
Close PRC (Delete_cell PRC). Open PRC (Backup PRC). Activate PRC (Backup PRC) in queued mode, without cell clean-up, without forcing the Cell Administrative State. Display Pending Activations List to see when the activation is finished.
30 / 32
2 Scenario
Note -
Task Description Close PRC (Backup PRC). Delete PRC. (Delete both the Backup PRC and Working PRC).
Outage -
O1
OMC-R
2 min.
Perform call tests for all impacted cells. CHECK O1 Display USD Detailed Cell Information. Perform GPRS calls on the extended cell (Inner / Outer). Check in the DTC report that each GPRS call is successful and print the DTC report. OMC-R OMC-R 5 min./ cell 15 min. None.
31 / 32
2 Scenario
32 / 32