5700A/5720A Multifunction Calibrators


5720A: The lowest uncertainties of any multifunction calibrator 5700A Series II: The world standard Specifications available at both 99% and 95% confidence levels Simplified support with complete confidence

The 5700A has undergone continuous improvements to become the 5700A Series II, one of the most tested and reliable high precision calibrators Fluke has ever produced. Considered the calibration standard worldwide, the 5700A delivers high value as well as accuracy covering 5 1/2 to 71/2 digit dmms. The 5720A offers even more. In addition to the dependability, simplified calibration, ease-of-use and worldwide support that has made the 5700A number one, the 5720A offers uncertainty specifications that rival anything available today. Customers can get all the performance they need to calibrate their most demanding workload of multimeters up to 81/2 digits quickly, easily and reliably. This improvement in performance results from factory testing to even tighter tolerances, and from a variety of hardware and firmware improvements.

Simplified support with complete confidence

Specifications available at both 99% and 95% confidence levels


Specifications for both the 5700A and 5720A are stated with a choice of confidence levels. You can use the conservative 99% specifications that Fluke traditionally publishes, or more aggressive 95% specifications recommended in many international procedures. In addition to allowing you to trade a small amount of risk for better performance, 95% confidence level specifications allow easier measurement intercomparisons. Both specifications are available at a press of the SPEC key for any output.

Ordering Information
Model
5720A: Multifunction Calibrator 5700A: Series II Multifunction Calibrator

Options
5700A-03: Wideband AC Voltage (compatible with both the 5700A and the 5720A)

Accessories
5720A: Amplifier 5220A: Transconductance Amplifier 5790A: AC Measurement Standard 734A: DC Reference Standard 732B: DC Standard 742A: Resistance Standards 792A: AC/DC Transfer Standard

Upgrade
5700A/EP UG: 5700A to 5720A Upgrade 5700A/EP UGP: 5700A to 5720A Upgrade with zero downtime priority service

Software
MET/CAL Plus: Automated Calibration Management Software

Both the 5700A and the 5720A feature Artifact Calibration. Only three artifact standards a 10V dc reference and 1 and 10 k resistance references are required to calibrate all ranges and functions to full specifications. Front panel instructions prompt the operator to make connections and inputs each step of the way. The calibrator controls the process, which takes only about an hour, compared to several hours using traditional methods. During the process, assigned values of an external artifact are transferred to a large array of multidimensional parameters within the calibrator. The calibrator takes over the manual metrology functions of establishing ratios and making comparisons, as well as controlling the measurement process. To assure confidence, the 5700A and 5720A can check themselves against their own internal standards to assure everything is working as expected. Those results can be printed out or downloaded to a computer. Thousands of 5700A calibrators in service around the world, as well as independent studies by leading national standards organizations, prove Artifact Calibration delivers fast, easy and inexpensive calibration along with the confidence that your instrument is performing as expected between calibrations.

Compatibility
Both the 5700A and 5720A can emulate, via the remote interface, either a 5100B or 5200A calibrator, permitting them to replace those older calibrators in automated systems with little or no impact on software. In addition, it is compatible with the 5725A Amplifier, 5220A Transconductance Amplifier and 5205A or 5215A Precision Power Amplifiers.

Increase confidence and efficiency while reducing ownership costs


The 5700A/5720A Calibrators feature Artifact Calibration. Only three artifact standards are required to calibrate all ranges and functions to full specifications. Front panel

CALIBRATION PRODUCTS

5700A Calibrator

5720A Calibrator

Summary Specifications*
5720A/5700A Multifunction Calibrators
Function DC Voltage AC Voltage Resistance DC Current AC Current Wideband AC Voltage Option Range 0 to 1100V 220 V to 1100V 10 Hz to 1 MHz 0 to 100 M, 18 values in x1 and x1.9 0 to 2.2A (11A with 5725A) 9 A to 2.2A (11A with 5725A) 10 Hz to 10 kHz 300 V to 3.5V, 10 Hz to 30 MHz Best 1 Year Specification 5720A 5700A 3.5 ppm of setting 7.0 ppm of setting 45.0 ppm of setting 75.0 ppm of setting 8.5 ppm 35 ppm of setting 120 ppm of setting 12.0 ppm 50 ppm of setting 140 ppm of setting 0.4 ppm of setting

* For detailed specifications, contact your Fluke representative or visit the Fluke web site at www.fluke.com.

instructions prompt the operator to make connections and inputs each step of the way. The calibrator controls the process, which takes only about an hour, compared to several hours using traditional methods. In addition to saving time and equipment costs, Artifact Calibration extends the need for external verification to two years or longer as required by your standards and procedures. And, because the 5700A Series II and 5720A can tolerate operating temperatures between 15C and 35C they can be calibrated where they are used, rather than having to be recalled to the standards laboratory for calibration.

For more information about specific 5700A/5720A applications, ask your Fluke representative for these publications: Calibrating the Hewlett-Packard 3458 DMM with the Fluke 5720A Multifunction Calibrator (Order No. A0582UEN) An Evaluation of Artifact Calibration in the Fluke 5700A Multifunction Calibrator (Order No. B0313UEN) Artifact Calibration Theory and Application (Order No. B0218UEN)

Elveveien 28, 3262 Larvik Tlf. 33 16 57 00 - Faks 33 16 57 01 post@instrutek.no - www.instrutek.no


CALIBRATION PRODUCTS

Test Equipment Connection Corporation is your single source test & measurement solution. We offer over 400 test equipment manufacturers including Agilent, Tektronix, Anritsu, Rohde & Schwarz, Advantest, Megger, LeCroy, Chroma and Fluke, plus thousands of New, Used, Second Hand, Pre-Owned, Demo, Refurbished, and Reconditioned test equipment products. For over 18 years, we have been providing high quality spectrum analyzers, mobile phone testers, oscilloscopes, network analyzers, service monitors, RF amplifiers, broadband amplifiers, signal generators, OTDR, fusion splicers, and digital multimeters at great savings to over 200,000 customers worldwide. Lease or rent from us, and we can help manage your idle assets using our consignment program. Trade in underutilized test equipment for cash or credit towards the test solutions you need today! TEC offers repair and calibration support for thousands of current and discontinued brands. TEC's GSA Contract #GS-07F-0358U provides lower cost test and measurement equipment to qualifying government contractors and agencies.

www.TestEquipmentConnection.com
USA & Canada:(800) 615-8378 Florida:(407) 804-1299 Mexico: 52-55-8421-4127 Chile: 2-897-4335 Brazil:301-32793 Fax: 800-819-8378 / 407-804-1277 Skype: TestEquipmentConnection United Kingdom: 20-8144-7837 Ireland: 1-442-8376 Sweden: 46-46-288-61-42 Denmark: 369-92915 Finland: 358-9-2316-3837 Belgium: +32 (2)808 0820 China: 86-136-3217-2095 Hong Kong: 852-2690-1360 Singapore: 65-6320-8596 Australia: 61-2-8011-3687 Skype: TEConnectionAsia Unit E4, 7/F., Phase I, Kaiser Estate, No. 41 Man Yue Street Kowloon, Hong Kong.

30 Skyline Drive Lake Mary, FL 32746 USA

Levels 20, Bastion Tower 5 Place du Champ de Mars B-1050 Brussels

6 Battery Road #31-00 Standard Chartered Bank Building Singapore 049909

Click Here to Request an Offer on Your Surplus Test and Measurement Assets Today

You might also like