Session15 IECLightingFundamentals

IlluminationLevels Example

IlluminationLevels (Cont.)

LightingSourcesintheIECWorld
Incandescent: 40C(40F) Fluorescent: 20C(4F)minimumstartingtemp. Luminousintensitylessthan10%@20C y @ LowtemperatureLampsprovide40C(40F) InductiveLamp:80C instantlightwith100,000hr.lamplife Availablein55,85and125wattunits HighPressureSodium: 50C(58F) Fullluminousintensityovertemperaturerange DualArcTubeversions instantlightwhenpowerisreapplied extremelylongratedlifeupto55,000hours

WhysomuchuseofFluorescentlighting intheIECworld
HIDLamptechnologymuchbetterinUSthanEurope Lowermountingheightsduetospacerestrictions&limitationsin Europevs.US p IntermediateTratingissue EnclosedandCasketednotapprovedprotection Zone2onlyrecentlyexpandedandproductsapproved ExnRrecentlyintroduced Lamp standardization Lampstandardization Qualityoflightissues LoweroverallLuxrequirements BettertechnologywithFluorescents(30Cratings) Italladdsuptomorefluorescents

LumenoutputofTraditionalFluorescent vs.coldtemperatureversions vs cold temperature versions


Traditionalfluorescentsprovidelittleornolightatambientsbelow15 Cwherespecializedlampscan Traditional fluorescents provide little or no light at ambients below 15C where specialized lamps can providebetterilluminationatcoldertemperatures.

Typicallightinginstallations
Theuseoffluorescentlamptechnologyevenforhighmountingrequirementsisfairly commonintheEuropeanmarket.Longlifefluorescentlampswithlamplifeupto 80,000hoursistypicallyusedinareaswherequalityoflightandaccessibilityis important

SupportSystemsInstallation LightingExamples g g p

Typicallightinginstallations
Fluorescentlampsusedonlonglinearspansforevendistributionoflightingand Fluorescent lamps used on long linear spans for even distribution of lighting and reductionofglarewithHIDlightsources

Typicallightinginstallations
CommonuseofHIDlightingistouseareflectorlampforhighmounting applications

Typicallightinginstallations
Althoughnotasfrequentlyusedtoday,stillsomeoffshoredesignswithhighwattageHID g q y y, g g g lightfixturesuseremoteballastsforeaseofmaintenanceandtoprolongtheballastlife.

Typicallightinginstallations
CombiningtheuseofHIDandfluorescentsfornormallightingisandhasbeenacommoninstallation Combining the use of HID and fluorescents for normal lighting is and has been a common installation practice.TheHIDlightingshowninthepictureisratedZone2whilethefluorescentbulkhead fixturesbelowareratedZone1.

Typicallightinginstallations
TheuseofHIDorFluorescentsisadecisionusuallybaseduponpreviousengineering The use of HID or Fluorescents is a decision usually based upon previous engineering installations.Bothproductsaresuitablebuteachhaveadvantagesanddisadvantages.