You are on page 1of 7

MagneRule Plus™

Magnetostrictive Linear Displacement Transducer

The MagneRule Plus™ magnetostrictive linear displacement Hostile Environments


transducer provides highly accurate absolute position MagneRule Plus™ operates in hostile industrial
measurement of displacement up to 120 inches (3 meters). environments with high temperatures and working
The sensor also measures velocity, giving feedback of both pressure. The sensor probe is pressure-sealed with an “O”
position and velocity simultaneously. ring to operate in hydraulic fluids up to 5000 psi. Integral
Operation is based on accurately measuring the distance electronics are protected against contamination from dust.
from a predetermined point to a magnetic field produced by Selectable Inputs/Outputs
a movable permanent magnet. The design and durability of
MagneRule Plus is powered by ±15 VDC or 24 VDC. By
the sensor make it ideal for measuring position of moving
providing an absolute output, no data is lost should power
machine members.
be interrupted. The long stroke sensor offers a universal
Excellent Performance analog position output, as well as a velocity output.
A marked improvement over potentiometers for long stroke Therefore, one unit can be stocked for multiple
position measurement, the MagneRule Plus™ possesses applications.
exceptional linearity, even over lengths up to 120 inches (3 Easy Installation
meters), with repeatability up to 0.002% of the
The design of the MagneRule Plus™ permits simple
measurement range. By utilizing magnetostrictive
mounting and hookup. Electronics are self-contained in the
technology, MagneRule Plus, requires no contact between
sensor head, eliminating the need for additional electronic
parts that cause friction or premature wear, offering high
packages. For external sensor installation, special mounting
reliability and extended life. Good stroke-to-length ratio
kits and various magnet options are available.
provides for a more compact long stroke position sensor.

Internet: www.schaevitz.com North America Tel: 800/745-8008


Document Fax Back: 916/431-6541 Europe Tel: (01753) 537622 104
MagneRule Plus™
Magnetostrictive Linear
Displacement Transducer
Technology Overview
Custom Designs Operation
For OEM applications with unique requirements, A trigger coil periodically sends short duration current
MagneRule Plus™ can be tailored to specific length and pulses (“start” pulses) down the waveguide. When the
mounting requirements. Schaevitz® also offers this sensor magnetic field accompanying the current pulses intersects
with alternate threading, special magnets, and tailored the magnetic field of the movable ring, magnetostriction
electronics. causes a momentary torsional strain in the wire. This strain
travels back down the wire and is converted back to an
Hardware electrical pulse (“stop” pulse) in the head. By measuring the
MagneRule Plus consists of a nonmagnetic, pressure-sealed time difference between the start and stop pulses, the
stainless steel tube (probe) welded to an enclosed stainless position of the magnet ring can be precisely determined.
steel base (head). The probe contains a stretched
magnetostrictive wire, and the head contains the Universal Analog Outputs
transducer's control electronics. A permanent magnet ring MagneRule Plus™ translates this time-based position
serving as a movable position marker slides over the outside measurement into an analog output signal. A user selectable
of the tube. 0 to 10 VDC voltage (either low or high frequency
response) or a 4-20 mA current (3-wire) output is available
State-of-the-Art Electronics in either forward or reverse slope signals. Additionally,
By utilizing the latest in surface mount technology in the velocity of the moving magnet ring (up to 10 in/sec) is
design of its electronics, MagneRule Plus™ provides state- generated by differentiating the position signal.
of-the-art features such as user-selectable inputs and
outputs in a smaller electronics package.

Noncontacting magnet
carrier ring

Longitudinal
magnetic field
S
End damper
N

Protective stainless
steel tube

N
Solid wire
wave guide S

Start pulse
Torsional deformation I in
of waveguide to wave guide
S (Pstart )
Current pulse Bias magnet
input ( Iin)
N Actual E o
from mode
converter
Mode converter Mode converter
output E o
Stop pulse
Electronically
conditioned
Eo (Pstop )
Pulse duration proportional
PWM signal generated
using Pstart and Pstop To magnetic ring position

Time

105
MagneRule Plus™
Specifications
Performance Specifications Outputs
Standard Ranges .............. 6, 12, 18, 24, 30, 36, 48, 60, 72, User Selectable Analog Output Signals
84, 96, 108 and 120 inches MagneRule Plus™ offers a universal analog output signal
(metric units also available) that is user-selectable. (Sensor gives feedback of both
Input Power ...................... ±15 VDC ±10% (70 mA) or position and velocity simultaneously.)
+24 VDC ±10% (90 mA)
(inputs are user-selectable) Users may choose one or all of the following analog
Output outputs when installing the sensor.
Displacement ................. 0 to 10 or 10 to 0 VDC at 2 mA Displacement Analog Voltage Output
max or 4 to 20 or 20 to 4 mA
(600 Ohm max loop resistance
❏ 0 to 10 VDC or 10 to 0 VDC at 10 Hz
at 24 V) (outputs are user- ❏ 0 to 10 VDC or 10 to 0 VDC at 100 Hz
selectable)
Velocity ........................... 1 V/inch/sec nominal (10 V The standard output, used for most commercial data AC
max) aquisition systems, is derived from a 4-pole, 10 Hz low
Nonlinearity ...................... 0.05% of full scale output pass filter. Output provides low noise and low ripple. For
(max) relatively fast servo system applications, there is a higher
Nonrepeatability ............... 0.002% of full scale (max) response output derived from a 3-pole, 100 Hz filter which
Resolution ......................... Up to 0.002% of full scale has low phase lag at 10 Hz.
Hysteresis .......................... 0.001 inches (max) Output voltage slope polarity may be reversed by
Frequency Response grounding a selected wire. Slope polarity change combined
Low Noise ....................... -3 dB at 10 Hz, -60° phase shift with the standard analog outputs gives 4 different sets of
at 10 Hz output characteristics: 0 to 10 VDC or 10 to 0 VDC at 10
Servo ............................... -3 dB at 100 Hz, -15° phase Hz and 0 to 10 VDC or 10 to 0 VDC at 100 Hz.
shift at 10 Hz (for other
frequencies consult factory) Slope polarity change is useful when it is necessary to
Update Frequency reverse the operating sense of the measurement, as in “top-
Range (inches) ............... (kHz) down” liquid level applications when the magnet/float at
6-12 .................................. 6.250 the end of the MagneRule Plus™ is equivalent to minimum
13-29 ................................ 3.125 level or empty. Other applications include “pull” instead of
30-63 ................................ 1.583 “push” hydraulic cylinder installations and machine tool
64-120 ............................. .781 motion control systems.
Operating Temperature Range
Displacement Analog Current Output
Probe ............................... -40° to 85°C
Head ................................ 0° to 70°C ❏ 4-20 mA or 20-4 mA at 10 Hz
Storage Temperature
This 3-wire, 4-20 mA current output is derived from a
Range ................................. -40° to 100°C
4-pole, 10 Hz filter.
Temperature Coefficient .. 0.007% of full scale per °C
Span Adjustment Range .. 20% of nominal range It is utilized in industrial and process control applications
Zero Adjustment Range ... 20% of nominal range where there are long cable runs between loop power
Ripple supply, readout equipment or PLC and the sensor.
Low noise (6 to 120") .... Less than 2 mV rms
Servo (6 to 63") .............. Less than 2 mV rms Output slope polarity can be reversed by grounding a
Servo (64 to 120") .......... Less than 10 mV rms selected wire, giving two position outputs: 4-20 mA or 20-4
mA at 10 Hz cutoff frequency.
Velocity
MagneRule Plus™ offers an uncalibrated velocity output
Physical Specifications derived from the position output. This analog voltage is
normally used for rate feedback stabilization in second
Probe .................................. 304SS wetted parts, 5000 psi order servo systems. Because it is the derivative of the
sealed (340 bar) position signal, it is only useful over a limited range of
Cover .................................. Anodized aluminum velocities, typically from 0.05 inches per second to 10
Cable .................................. 10 feet (3m) PVC jacketed inches per second. Consult factory for other ranges.
O-rings ............................... Viton®
Magnet Ring ...................... Ertalyre*

Viton® is a registered trademark of DuPont

Internet: www.schaevitz.com North America Tel: 800/745-8008


Document Fax Back: 916/431-6541 Europe Tel: (01753) 537622 106
MagneRule Plus™
Magnetostrictive Linear
Displacement Transducer

Dimensions in (mm)

Pin Connector Termination Measuring Range


+ 4.50 (114.30) Max
0.36 Max 4.40 Max 2.0
(9.14) (111.76) (50.8) ref 2.5
(63.5) ref
Viton O-Rings 0.43
(10.92)
A 3/4-16UNF2A
Ø1.72 1.290
Pin Connections (Ø43.69) (32.77)
A +15 V IN/+24 V IN Zero Span adjustment
A Ø.405
B Common Ground adjustment 20% of nominal (Ø10.287)
C Analog Ground 0.85 20% of range
(21.59) nominal Magnet Ring
D -15 V IN range Assembly
E V Out, 100 Hz
F V Out, 10 Hz
G Velocity
H Current Zero Trim View A-A Span Trim
Potentiometer Potentiometer 0.53 dia.
J Reverse (Connect to red Sealing Screw Sealing Screw (13.5)
A
or cap off with no
1.29 dia.
connection for standard (32.8)
slope polarity) (Connect 0.152 (3.9)
Holes equally
to black for reverse spaced on
slope polarity) Wt. 13.32 ±. 2g 0.94 dia. (23.9)
bolt circle
K No connection Ring Magnet Assembly

Cable Termination 10 ft (3 m) Measuring Range


+ 4.50 (114.30) Max
4.40 Max 2.0
(111.76) (50.8) ref 2.5
(63.5) ref
Viton O-Rings 0.43
Cable (10.92)
A 3/4-16UNF2A
Color Function
Brown V Out, 100 Hz Ø1.72 1.290
(Ø43.69) (32.77)
Blue Analog Ground
0.86 Zero Span adjustment
Black Common Ground A Max Ø.405
adjustment 20% of nominal
Violet Current (21.84 0.85 (Ø10.287)
20% of range
Green V Out, 10 Hz (21.59) nominal Magnet Ring
range Assembly
Orange Reverse (Connect
to red or cap off Zero Trim Span Trim
with no connection Potentiometer View A-A Potentiometer
Sealing Screw Sealing Screw 0.53 dia.
for standard slope (13.5)
polarity) (Connect A
to black for reverse 1.29 dia.
(32.8)
slope polarity)
0.152 (3.9)
White -15 V IN Holes equally
spaced on
Red +15 V IN/+24 V IN Wt. 13.32 ±. 2g 0.94 dia. (23.9)
bolt circle
Yellow Velocity
Ring Magnet Assembly

107
MagneRule Plus™
Accessory Mounting Kit and Float Assembly
Mounting Kit
Magnet Ring/Bracket
For simplified external sensor Assembly
installation, mounting kits are Open Magnet
available that include Ring
appropriate mounting and
support brackets, and an
open magnet assembly.
To order specify kit:
MK-1 (For lengths of <4 feet)
1.94
MK-2 (For lengths >4 feet) (49.28)
Screw 6-32
Split Washer

0.257 Dia. (0.653)

Magnet Bracket

Open Magnet Ring


0.15 Dia. (3.81)
4 Places on 0.94
Radius (23.9)

ID = 0.53
(13.5)
Tube Bracket 0.31 Thick (7.87)
1.00
(25.4)
0.12 Dia. 0.50 OD = 1.29 0.42
(3.0) (12.7) (32.8) (10.7)

1.73 Magnet Bracket


0.26 Dia. (43.9)
▼ 1.38
(6.60) #6-32 UNC-28
(35.1) (2 places)

1.72
▼ ▼ (43.7)
0.88

(22.4) 0.12
(3.05) 0.88
1.75 (22.4)

(44.5) 0.12 Dia. (3.05)


Retainer Band (4 Places) 0.12 0.88
(3.05) (22.4) 0.27 0.27
1.75 (6.9) (6.9)
(44.5) 0.75
(19)

Mounting Kit Assembly in (mm) Note: For MK-2 kits, three tube brackets should be
spaced so that each distance x is approximately equal

x x x
Transducer
Bracket
Jam Nut Magnet Ring/bracket
3/4 -16 UNF-2A Assembly
0.750 (19.05)

Retainer band
1.94 Two Extra Brackets
(49.28) Provided in
Mounting Kit Tube bracket
MK-2

Internet: www.schaevitz.com North America Tel: 800/745-8008


Document Fax Back: 916/431-6541 Europe Tel: (01753) 537622 108
MagneRule Plus™
Magnetostrictive Linear
Displacement Transducer

Float Kit
Float Kit Assembly in (mm)
MagneRule Plus™ can
monitor the actual fluid
level in a container with
the addition of a float
kit. The MagneRule's
stainless steel rod is
positioned directly into
the fluid. A spherical
float containing an
integrated permanent
magnet measures the
fluid level. The float kit
includes a spherical
float, retaining collar,
and transducer bracket.
The entire assembly is
mounted vertically.
Hex Base
To order specify: FK-1 Spherical Float

Jam Nut
3/4 -16

Transducer
Bracket

1.94
(49.28) South End
Spherical Float
South
62890124-000

0.55 Spherical Float


2.00 (14)
(50.8)

Retaining Collar
Retaining Collar

0.87
(22.1) 0.75 ± 0.03
(19.05 ± 0.76)
0.37
(94)

0.41
(10.4)

109
MagneRule Plus™
Ordering Information
How to Order
Ordering Example:
A standard ring magnet assembly, nonmagnetic mounting
screws and hole-location templates are shipped with each Model Number MRU-3000-012 is a MagneRule Plus™
MagneRule Plus™. When ordering please complete model with a standard (V/in) calibration, standard output,
number by specifying unit ouput and measurement range. standard cable termination, standard base, and a standard
12 inch range.

MRU - 3 0 0 0 — 012(1)

Calibration
3 V/in (standard)
4(1) V/cm (optional)

Output
0 User-selectable analog outputs (standard)

Termination
0 Cable Termination (standard)
2 Connector termination (optional)

Base
0 Imperial mounting hole dimensions (standard)
1 Metric mounting hole dimensions (optional)

Unit Range(1)
Specify range from 6 inches (006) or 15 cm (015) to 120 inches (120) or 305 cm (305)
Code Inches Code Centimeters
006 6 inches (standard) 015 015 cm (standard)
012 12 inches (standard) 031 030 cm (standard)
018 18 inches (standard) 045 045 cm (standard)
024 24 inches (standard) 061 061 cm (standard)
030 30 inches (standard) 076 076 cm (standard)
036 36 inches (standard) 091 091 cm (standard)
048 48 inches (optional) 122 122 cm (optional)
060 60 inches (optional) 152 152 cm (optional)
072 72 inches (optional) 183 183 cm (optional)
084 84 inches (optional) 213 213 cm (optional)
096 96 inches (optional) 244 244 cm (optional)
108 108 inches (optional) 274 274 cm (optional
120 120 inches (optional) 305 305 cm (optional)

(1)
For metric calibration (V/cm), unit range is specified in centimeters.

Internet: www.schaevitz.com North America Tel: 800/745-8008


Document Fax Back: 916/431-6541 Europe Tel: (01753) 537622 110