You are on page 1of 8

Nestlé European Information Technology Operations Center (ITOC) S.A.

SNOASIS - How to reset user's session


Author : Steve Rosa
Authoriser : Fabian Geurts

Creation Date : 14-Oct-2004


Save Date : 14-Oct-2004
Print Date : 14-Oct-2004

Synopsis : This document describes the steps to follow to reset a user's session on the
European Citrix farm.

Revision History
Revision Revision Summary of Changes Changed by
Number Date (Acronym)
1.0 14/10/04 First Release SRO

File: 8909685.doc Version: 1.0


Author: Steve Rosa Page 1 of 8
Saved on 14/10/2004 03:38:00 AM
Last printed 14/10/2004 10:10:00 AM
Nestlé European Information Technology Operations Center (ITOC) S.A.

Table Of Contents

1. Introduction ...................................................................... .........................3

2. Prerequisites.............................................................. ................................3

3. Procedure................................................................... ................................3

File: 8909685.doc Version: 1.0


Author: Steve Rosa Page 2 of 8
Saved on 14/10/2004 03:38:00 AM
Last printed 14/10/2004 10:10:00 AM
Nestlé European Information Technology Operations Center (ITOC) S.A.

1.Introduction
On some occasions, a user connected to a Citrix server may experience an issue. In order to solve
his issue, sometimes the only solution is to reset his session on the server.
In order to do this, the user can contact his local service desk and request his session to be reset.
This document is intended to the market’s service desk and explains how to perform the reset of
the session.

2.Prerequisites
The Service Desk analyst who wants to perform the reset needs the following items:
• the ICA client installed on the analyst’s PC must be configured for his adm account as per the
document: M_04_Configuring ICA client for EURCTXFarm.doc.
• his adm account must be member of the following groups:
o XX: CTXFarmUsers 1
o EUR: CTXFarmSupport Read-Only CMC and Reset Sessions 2

3.Procedure
Start the Citrix ICA Client:

Double-click on the EURCTXFarm Application Set:

1
This group is managed at market level.
2
This group is managed at GC level.

File: 8909685.doc Version: 1.0


Author: Steve Rosa Page 3 of 8
Saved on 14/10/2004 03:38:00 AM
Last printed 14/10/2004 10:10:00 AM
Nestlé European Information Technology Operations Center (ITOC) S.A.

Double click on the Farm Management folder:

Then, start the Citrix Management Console by double-clicking its icon:

File: 8909685.doc Version: 1.0


Author: Steve Rosa Page 4 of 8
Saved on 14/10/2004 03:38:00 AM
Last printed 14/10/2004 10:10:00 AM
Nestlé European Information Technology Operations Center (ITOC) S.A.

If you get the following screen:

Fill it like displayed here (using your adm account):

File: 8909685.doc Version: 1.0


Author: Steve Rosa Page 5 of 8
Saved on 14/10/2004 03:38:00 AM
Last printed 14/10/2004 10:10:00 AM
Nestlé European Information Technology Operations Center (ITOC) S.A.

Then, you should be able to access the CMC:

File: 8909685.doc Version: 1.0


Author: Steve Rosa Page 6 of 8
Saved on 14/10/2004 03:38:00 AM
Last printed 14/10/2004 10:10:00 AM
Nestlé European Information Technology Operations Center (ITOC) S.A.

The next step is to locate the session that the analyst wants to reset. Therefore, you must browse
the Servers tree, locate the server group or the server and then the session:

File: 8909685.doc Version: 1.0


Author: Steve Rosa Page 7 of 8
Saved on 14/10/2004 03:38:00 AM
Last printed 14/10/2004 10:10:00 AM
Nestlé European Information Technology Operations Center (ITOC) S.A.

Once you have located the session, right-click on it and choose Reset:

The console will ask you a confirmation. Click on Yes:

The session will reset within a few seconds.

File: 8909685.doc Version: 1.0


Author: Steve Rosa Page 8 of 8
Saved on 14/10/2004 03:38:00 AM
Last printed 14/10/2004 10:10:00 AM