MeiStream

Bulkmeter for cold potable water DN 40...150

Main characteristics
Meter with MID pattern approval acc. to annex MI001 Pattern approved removable measuring insert (75/33/EEC) Unique measuring range High overload capability No straight inlet length necessary (acc. to OIML R49 and EN 14154) Unlimited fitting position Meter body in short (WP) and long (WS) overall length acc. to DIN 19625 and EN 14154 available Measuring insert fits the meter body of WP-Dynamic Used materials are temperature resistant up to 70C Register prepared for HRI-Mei pick-up Use of optical pulsers type OD is still possible

Applications
Measurement for billing of cold potable water up to 50 C Measurement of high flowrates e.g. in pumped pipes Measurement of low flow e. g. in light load periods For leakage control

Available options
Version free of copper alloy for aggressive water Version for high pressure up to PN 40 Version for use in hazardous area HRI-Mei factory mounted 1/4 pressure monitoring port

Bermad Water Technologies Ph (03) 9464 5421

www.sensus.com

Approval mark
Meter cpl.
Marking CE M-XX* 0102 * year of production DE-09-MI001-PTB 010

Measuring insert D06 6.132.47


Size: DN 40 ... 150

Marking:

metrological class B; 30C

Performance Data
Size Q5 Q4 Q3 Q3 Q2h Q1h Q1h Q2v Q1v Q1h Q3/Q1 h Q3/Q1 v Q3/Q1 Max. Peak Flow Overload Flowrate acc. to MID Continuous Flow Permanent Flowrate acc. to MID Transitional Flowrate horizontal acc. to MID Minimum Flow horizontal acc. to MID Minimum Flow horizontal Transitional Flowrate vertical acc. to MID Minimum Flowrate vertical acc. to MID Minimum Flow vertical max. Ratio horizontal max. Ratio Vertical Standard Marking Starting Flow m3/h bar DN m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h 40 60 31,25 40 25 0,32 0,2 0,2 0,4 0,25 0,25 125 100 63 0,05 0,08 50 90 50 50 40 0,4 0,25 0,15 0,51 0,32 0,28 160 125 100 0,05 0,18 65 120 78,75 70 63 0,63 0,39 0,2 0,81 0,5 0,4 160 125 100 0,07 0,37 80 200 125 120 100 0,51 0,32 0,2 0,8 0,5 0,5 315 200 100 0,1 0,16 100 300 200 230 160 0,81 0,51 0,3 1,28 0,8 0,5 315 200 100 0,11 0,34 125 350 200 250 160 1,02 0,64 0,5 1,6 1 1 250 160 100 0,15 0,36 150 600 500 450 400 1,6 1 0,8 3,2 2 1,6 400 200 100 0,3 0,32

Headloss at Q3 acc. to EN 14154

Dial
Nominal diameter DN 40 ... 125 150 Smallest reading m3 0.0005 0.005 Max. reading m3 1,000,000 10,000,000

DN 40...125

DN 150

Bermad Water Technologies Ph (03) 9464 5421


LB1010INT Page 2

Typical Headloss
DN 80 DN 100 DN 125 DN 150 DN 40 DN 50 DN 65

Typical Error Curve

Headlossloss Head

Error %

Flow rate m/h 3/h Flowrate m

Flowrate m3/h

Pulse Values
Pulser Type HRI-Mei (Leaflet see LS 8400) OD 01 (Leaflet see LB 8300) OD 03 (Leaflet see LB 8300) DN 40 ... 125 0.01; 0.05; 0.1 or 1 m3 0.001 m3 0.01 m3 Pulse Value DN 150 0.1; 0.5; 1 or 10 m3 0.01 m3 0.1 m3

Pipe

horizontal vertical inclined upwards sideways

Dimension Picture

Meter head

Installation Requirements Installation


Unrestricted straight pipe upstream 0 x DN No abrupt restrictions directly downstream of the meter

Materials
Body Measuring element Rotor Cast iron Plastic Plastic

Available Lengths
Nominal diameter Overall length L WS (DIN / ISO) Overall length L WP (DIN / ISO) mm mm 220 40 50 65 80 100 125 150 500 250 300

270 / 300 300 200 200

300 / 360 / 350 350 225 / 200 250

We also use the following Brass materials Stainless steel

Bermad Water Technologies Ph (03) 9464 5421

MeiStream
LB1010INT Page 3

Dimension and Weights PN 16


Nominal diameter Dimensions Overall length Height h Dismantling height g Weights Meter cpl. Measuring insert Body L mm H mm mm mm kg kg kg 40 220 120 69 200 7.5 1.5 6.0 50 200 120 73 200 7.8 1.5 6.3 50 311 120 73 200 10.3 1.5 8.8 50 300 120 73 200 9.9 1.5 8.4 65 200 120 85 200 10.1 1.5 8.6 65 300 120 85 200 12.0 1.5 10.5 80 200 150 95 270 13.8 3.2 10.6 80 225 150 95 270 14.2 3.2 11.0

Nominal diameter Dimensions Overall length Height L H h Dismantling height g Weights Meter cpl. Measuring insert Body mm mm mm mm kg kg kg

80 413 150 95 270 18.7 3.2 15.5

80 350 150 95 270 17.7 3.2 14.5

100 250 150 105 270 18.2 3.2 15.0

100 350 150 105 270 20.0 3.2 16.8

100 483 150 105 270 22 3.2 19

125 250 160 118 280 20.7 3.2 17.5

150 300 177 135 356 35.9 5.9 30.0

150 500 177 135 356 44.2 5.9 38.3

Order Information
Description MeiStream DN 40 50 C / PN16 MeiStream DN 50 50 C / PN16 MeiStream DN 50 50 C / PN16 MeiStream DN 50 50 C / PN16 MeiStream DN 65 50 C / PN16 MeiStream DN 65 50 C / PN16 MeiStream DN 80 50 C / PN16 MeiStream DN 80 50 C / PN16 MeiStream DN 80 50 C / PN16 MeiStream DN 80 50 C / PN16 MeiStream DN 100 50 C / PN16 MeiStream DN 100 50 C / PN16 MeiStream DN 100 50 C / PN16 MeiStream DN 125 50 C / PN16 MeiStream DN 150 50 C / PN16 MeiStream DN 150 50 C / PN16 Overall Length in mm 220 200 270 300 200 300 200 225 300 350 250 350 360 250 300 500 Order Number 50401 AHI1C B1A1X 50401 BIL1A B1A1X 50401 BIL1F B1A1X 50401 BIL1G B1A1X 50401 CKL1A B1A1X 50401 CKL1G B1A1X 50401 DLL1A B1A1X 50401 DLL1D B1A1X 50401 DLL1G B1A1X 50401 DLL1I B1A1X 50401 EML1E B1A1X 50401 EML1I B1A1X 50401 EML1J B1A1X 50401 FML1E B1A1X 50401 GOL1G B1A1X 50401 GOL1N B1A1X

Certified according to ISO 9001 Quality Management System QS Reg.no. 3496/0

Bermad Australia ph (03) 9464 5421

UK & Ireland Enquiries Sensus Metering Systems 11 The Quadrangle, Abbey Park, Romsey, Hampshire SO51 9DL UK T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: info.gb@sensus.com www.sensus.com International Enquiries Sensus Metering Systems GmbH Hannover Meineckestrae 10, D-30880 Laatzen Germany T: +49 (0) 5102-74-0 F: +49 (0) 5102-74-3341 Email: info.int@sensus.com www.sensus.com 09001 Subject to changes without prior notice.

LB1010INT Page 4