You are on page 1of 82

CDR18

6.4 TFT LCD640480


18
I/O

LCD
LCD

1746.9

CF

RS232/422/485

18-bit
15-bit

Channel18
200ms/

CHUNDE

//

2.2

1.

1.1

1.2

1.3

1.4

CF

1.5

1.6

IR

1.7

1.8

2.

13

2.1

13

2.2

13

2.3

16

2.3.1 ( AI 181AI 182AI 183)

16

2.3.2 (DO181) / 6

17

2.3.3 (DI181)

17

2.3.4 (AO183IAO183V)

17

2.3.5 24VDC (AP181)

17

2.4

18

2.5

RS232/422/485

21

2.6

CF

22

3.

23

3.1

Page

23

3.2

Mode

24

3.3

History

24

3.4

Event

25

3.5

Status

27

3.6

Exit

27

3.7

Dump

27
1

3.8

Clear

27

3.9

Operate

28

3.10

Shutdown

28

3.11

28

4.

30

4.1

31

4.2

38

4.3

40

4.4

44

4.5

46

4.6

FDA21 CFR part11

47

4.7

48

4.8

48

4.9

50

5.

52

5.1

52

5.2

Ethernet

55

5.3

RS232RS485RS422

59

5.4

CF

62

5.5

Real-Time Viewer

64

5.6

DDE

67

6.

73

7. -

75


CDR18 EN61010-1UL61010C-1 CSA C22.2 No. 24~93

1.

2.
//

3. ERROR

4.

5.

6.

7.

CF

90~250VAC
2.5A / 250VACTime-lag 11~18VDC 18~36VDC 5.0A / 250VAC
Time-lag

1.
1.1
CDR18
6.4 TFT LCD 640 x 480
18



CF
174mm
Ethernet RS232 /422/485
18-bit A-D
15-bit D-A
200

1.2
6 I/O
(AI181, AI182, AI183,AI183)

DIP JUMP
2.3
(DO181) 6 5 A/240VAC
(DI181) 6 Logic Low5V 0.8V Logic High
2V 5V
4

(AO183IAO183V) 3 AO183I 4~20mA0~20mA


AO183V 0~5V1~5BV0~10V

1.3
IEEE 802.3 10 Base T Ethernet
RS-232 / RS-422 / RS-485
1.4 CF
8MB 128MB CF
CF
/
CF CF USB CF
512MB1GB CF
CF San Disk

CF CF CF
CF
CF 6
CF

128 MB

512 MB

1 GB

120

480

960

10

1200

4800

9600

120

14400

57600

115200

CF 2 bytes
128MB CF 24 736
[=32 MB / (2bytesx24 x60 x 60 )] 32bytes
32bytes
= CF / ( 2 bytes /1S, 2S, 5S, 10S.. x
x 3600 )
CF
CF
1.5

1.6 IR
LCD 2

:
IR10

1.7

CDR18
1 2 3 4

5 6 7

8 9 10

1
490-250VAC, 47-63 Hz
520-28VAC, 47-63 Hz
611-18 VDC
718-36 VDC
9
2
0
11 AI181
22 AI182
33 AI183
44 AI181AI183
55 AI182AI183
66 AI183
A9 AI183
B12 AI183
C15 AI183
D18 AI183
3
0
16
212
318

424
530
636
6

G3 AI183V
H6 AI183V
J9 AI183V
K12 AI183V
L15 AI183V
M18 AI183V

AI181/2/3(V) P.8

4
0
16
212

318
424

5
0
1RS-232/422/485 ()
9

6
1Observer
2Observer RS232/422/485

7
0
1 FDA21 CFR II
8
1128MB CF (Compact Flash Card)
5512MB CF
61GB CF
X
9
1
2/
3/
4
5/
6/
10
0
124VDC ( , 6 )
23 AO183I
36 AO183I
7

49 AO183I
D3 AO183V
E6 AO183V
F9 AO183V
5
6
724VDC 15
824VDC 16
924VDC 156
X

6 6 24VDC

12 4 3
2 /

RS-232/422/485

AI181, AI182, AI183


AI183V
DI181
DO181
AP181
CM181
CM182
PM181
PM182
PM183
PM184
PM185
PM186
MK181
MK181B
MK183
MK183B
MK184

1 / 2 / 3 (TC, RTD, mA, V, mV)


3 (mA, V, mV)
6
6 AC/DC
24VDC 6
RS-232/422/485

90-250VAC, 47~63Hz
11-18VDC
18-36VDC
90-250VAC, 47~63Hz
36-72VDC
20-28VAC

//
//
//
8

MK184B
CF032
CF256
CF1000
AS181
AS182
AO183I
AO183V
BT181
BT182
SC181
SNA10A
UMCDR181

//
32MB CF
256MB CF
1GB CF
-
-
3 0~20mA / 4~20mA
3 0~5V / 1~5V / 0~10V
Boot ROM
Boot ROM FDA21 CFRII

RS-485 RS232

1.8
90-250VAC47-63Hz60VA30W maximum
11-18VDC or 18-36 VDC 60VA30W maximum
6.1TFT LCD 640480 pixel256
8MB
128MB512MB1GB
AI181,AI182,AI183
AI1811 AI1822 AI1833
18 bits
5 /
-2VDC 12VDC1 minute for mA input
mA 3.0V /
1.5V /
T/C0.2V / ohm
3 RTD2.6/
2 RTD2.6/
200nA
CMRR120dB
NMRR55dB
430VAC
TCRTDmV
4-20mA 1mA
1-5V 0.25V

TCRTDmV 10 4-20mA 0.1


9

AI181/AI182/AI183

25

120~1000

2.2M

200~1370

2.2M

250~400

2.2M

100~900

2.2M

0~1820

2(200~1820)

2.2M

0~1768

2.2M

0~1768

2.2M

250~1300

2.2M

200~900

2.2M

PT100 (DIN)

210~700

0.4

1.3K

PT100 (JIS)

200~600

0.4

1.3K

mV

8~70mV

0.05%

2.2M

mA

3~27mA

0.05%

70.5

0~1V

0.12~1.15V

0.05%

332K

0~5V

1.3~11.5V

0.05%

332K

1~5V

1.3~11.5V

0.05%

332K

0~10V

1.3~11.5V

0.05%

332K

AI181V,AI182V,AI183V
AI183V

25

-60~60mV

62~62mV

0.1%

2.2M

-20~20mA

22~22mA

0.1%

70.5

-2~2V

2.2~2.2V

0.3%

332K

-20~20V

22~22V

0.1%

332K

(DI181)
6
5V 0.8V
2V 5V
1K
1.5 M
(DO181)
6
N.O. (form A)
5A / 240VAC 20

10

AO183I,AO183V
3
AO183I4~20mA0~20mAAO183V0~5V1~5V0~10V
15 bits

0.050.0025/
0~500 10K
0.01
0.1 99.9
1000VAC min.
0.005
0.0025 /
24VDC (AP181)
6 24VDC
241 VDC 180mA30mA/
RS-232/422/485 (CM181)
RS-232 (1 )RS-485 RS-422 ( 247 )
Modbus RTU
1 247
0.3 ~ 115.2Kbits / sec.
7 8 bits
None Even Odd
1 2 bits
Ethernet
Modbus TCP / IP 10 Base T
AUIAttachment Unit Interface RJ-45

2
10, 20, 30, 40, 50 60
()

()

10~40

18

0 50

52

-10 60

107

11


5 ~ 50
-25 ~ 60
20 ~ 80% RH() 80 31

40 50
2000
20M (500VDC )
1350VAC50/60Hz1
10-55Hz 10m/s
30m/s (3g) 100g

166 (W) x 144 (H) x 174mm (D)


166 (W) x 192 (H) x 194mm (D)
138 x 138mm DIN

UL61010C-1CSA C22.2 No.24-93


CEEN 61010-1 (IEC1010-1) Over Voltage Category Pollution degree 2
IP30
IP20

EN61326(EN55022 class AEN61000-3-2EN61000-3-3)


EN61326(EN61000-4-2EN61000-4-3EN61000-4-4EN61000-4-5
EN61000-4-6EN61000-4-8EN61000-4-11)

12

2.
2.1

2.2
CDR18

CDR18

CDR18
LEVEL II IEC1010-1EN 61010-1

5 ~ 50

20 ~ 80% RH( )

90 ~ 250 VAC, 50/60 Hz11 ~ 18 VDC 18 ~ 36 VDC

2-1

2-2

2-3 ( DIN 138mm x 138 mm )

13

MK184 (
2 1 2 )
FV-R 2- 4 2- 8

FV-L
2-9

2- 9 2- 10 2-11
2-12 2-14
2- 4

2- 5

14

2- 6

2-7

2- 8

2- 9
2-10

2-11

15

2-12

2-13

2-14

MK184( 2
1 /)

2.3
2.3.1 ( AI 181AI 182AI 183)
AI 181AI 182 AI 183 123
(JKTEBRSNL )PT100mVmAV
JUMP&DIP SWITCHES
2-15 JUMPERS DIP
SWITCHES I
/ O
4~20mA
2-15 Jumper DIP Switches

16

( AI 183V)
AI 183V 3 60mV20mA
2V20V
2-16 JUMPERS
DIP SWITCHES
I / O
20mA~20mA
2-16 Jumper DIP Switches

2.3.2 (DO181) / 6
6 N.O. 5A/240VAC

(System Info)DO

4.1
2.3.3 (DI181)
6 Event 12345 & 6

DI
2.3.4 (AO183IAO183V)
AO183I 3 AO183V 3 PV

2.3.5 24VDC (AP181)


241 VDC 180mA
30mA
17

2.4 /

1
22A/250VAC
2A/250VAC
3 0.7 N-m6.3 Lb-in
7.1 Kg F-cm

4 18AWG

5 1.6

2-17

6
24VDC

18

2-18 AI181/182/183

2-19 AI181V/182V/183V

2-20 DO181

2-21 DI181

19

2-22 AO183IAO183V

2-23 24VDC (AP181)

20

2.5 RS232RS422RS485

2-24 RS232

2-25 RS422

21

2-26 RS485

2.6 CF
CF CF
SanDisk
CF CF
CF
CF

CF CF
CF Card Reader USB CF

I / O

22

3.

evntmemCF /

3-1

3.1
6

/Enable 3-2

23

3-2

3.2

4.2

4.2

3.3


1 Sec/Dot9min/Page1hr/Page12hr/Page1day/Page 1week/Page

24

3-3

3.4
//
3-4
/
/

/
"/

25

3-4

3-4 /


FDA21 CFR part II


1~6
1~18 AI1~AI18 //Math1~Math18 //

26

3-5

3.5

DIDO
DIDO
3.6

3.7
CF CF
3.8
25%

25%

CF

mem 11 CF 1
27

CF 1
CF CF
evnt
10 Cf
CF 10 CF CF

3.9

4.1
4.
3.10

3.11 ( ):
Buzzer

evntevnt 61%
61% 4.4 /
25 %

mem
25 %

ROM 10
CF
CF

CF CF CF X CF
CF X CF
CF
25% CF CF
ROM
28


4.5

29

4.

Demo

4-1

4-1
CF
CF CF
CF
CF

30

4.1

AI

4.1
4.8

4-2

BackSP
Caps

26

31

1 / 2 / 5 / 10 / 30 / 60 / 120

11

1.8 1.8

1
2.3

VmVmAT/CJKTEBRSNL
PT100JPT100
4~20mA
//V/mV/mA

Range
A / 1-50-5
0-10V 0-20mA4-20mA I/O JUMP & DIP
SWITCH
BT/C PT100
Scale
(T/C PT100 )
Low
High

0~5V
0.0 150.0 0V 0.05V 150.0
1.5V 45.0
/ 45536 4553.6 455.36 45.536
4.5536 0.45536
2 .
32

DO

HLHHLLRr
H
L
HH H
LL L
R

1 100 100

1 2
1/ 2(H/L/HH/LL/R/r)
50

H 50

/
/

33

DO On ON DO1~DO6
DO Off OFF DO1~DO6
DO HLR Relay ON
Relay OFF DO1~DO6
Timer1~Timer6
Timer1~Timer6
Tolz1~Tolz18
0 Tolz1~Tolz18
Tolz1~Tolz18
Tolz1~Tolz18
Cont1~Cont 6
0 Cont1~Cont 6
Cont1~Cont 6
Cont1~Cont 6
3.4
////
//

0.1~10 Relay

200mS
1S

200 m sec

200 m sec

200 m sec

200 m sec

34

6 Relays DO1~DO6 Relay


DO DO
DI
DI 4-3
DI

AO AO183I
0~20mA 4~20mA AO183V
0~5V1~5V 0~10V

4-4

Scale LowScale High


4-5
AI / AI183V / AI183I
6.

Math1~Math18

4-3

35

4-4

36
4-5

+
*
/

36

SIN(x)
COS(x)
EXP(x)
SQRT(x)
LN(x)
TG(x)
CTG(x)

sin(x)
cos(x)
ex
x
loge(x)
tan(x)
1/tan(x)

ASIN(x)

Sin-1(x)

ACOS(x)

Cos-1(x)

ATG(x)

Tan-1(x)

LOG(x)

ABS(x)

SQ(x)
ROUND(x)

x2
x

HI(x,y)

x,y

LO(x,y)

x,y

INV(x)
PCT(x,Hi,Lo)

1/x
x (Hi-Lo), x: , Hi: , Lo:

x%y

x y

x^y

xy

Boot
ROM

1 4.1

2/
3 4.2

123 4

4 4 MATH1
5
6

37

4.2

4-6

Low

High
4-6

1-2-3-
Low
High

1~6
1~6 1~6 4-7

LowHigh Scale LowScale High


0-10V Scale Low0.00Scale Hi100.00
38

Low0.00High50.00
0.00 50.00

T/C PT100 Range


scale Low&High P.39

6 18
AI2AI5 Math14

Scale Low Scale High


4-7

39

4.3

4-8

4-8

1~ 6

1 2 4.1
//

4-9 ///

1~ 6
40

------17
01
AI1 MinMaxAve~AI6 MinMaxAve

4-9

1~ 6

4-10

41


99
NoHL
H25
25 DI /

1 2 4.1

1~ 18

60 L / HR. 60L

LBar

NoHL
H
999 999
1 2 4.1
4-11

42

830 1730

8:30
1
2

Tolz1
Tolz1

2
:
17:30
1
2

xxxx

Tolz1
Tolz1

xxxxxxxxxxxxxxxxx

AI1

xxxx
0.0

No

1
2
1
H
xxxx

DO
2
L
xxxx

DO
9901,0101,0201,020
980 5,020

43

4.4

4-12

Language

/ 2565121024
CFR-21
8

CFR21CFR21 FDA 21 CFR part 11


Administrator
Supervisor
Operator

CFR21 30

10

4.6
FDA21 CFR part11

44


CF 8MB

CF 8MB

LCD
11020304050
60

10

10
10 LCD

IR IR 2
IR
10 2
10

IRLCD IR 2

PC RS-232/RS-422/RS-485
Ethernet

PC RS-232/RS-422/RS-485
RS-485 0 247
1,2002,4004,8009,60019,20038,40057,600 115,200

No,8,1 / Odd,8,1 / Even,8,1


PC Ethernet
IP IP
45

IP IP

IP

IP IP
System Info 4.6
IP IP IP
IP

4.5

mm/dd/yydd/mm/yy
/

4-12

46

4.6 FDA21 CFR part11


4.4 CFR-21

CFR21 FDA 21 CFR part11


AdministratorSupervisor
Operator

CFR21 30

10

4-13

Administrator
Supervisors Operators

30
Supervisors

Operators

47

4.7Demo
DEMO 18 12 6
6 DEMO

DEMO
DEMO

4.8

CF
Ethernet IP

4-14

V2.20 2.20
V2.20 Plus
Rom Boot ROM
/
8MB

4-11

48

CF /
CF
4-11 CF
Ethernet IP IP
16 I/O
CF CF

49

4.9
3 4-20mA 6 Ethernet

AI183JUMPDip Switch 4-20mA


2.3

AI183 SLOT1
DO181 SLOT2

2.4 2.2

4.1

Scale Low Scale High

1
4-20

Scale Low0.00
Scale High100.00

123
4.1

50

Ethernat

IP
4.4

4.2~4.5

Observer

Observer
CF 2.5

CF
CF

51

5. Observer I& Observer II


5.1
HELP
Observer IObserver II

CONFIG_VIEWER
HIST_VIEWER
REAL TIME_VIEWER()

logging

CPU 200MHz
64 MB RAM
100MB
RS232 / RJ-45female / USB / CF Card Reader

Windows 98Windows MEWindows 2000Windows Xp WindowsNT

Setup

52

2
1 Windows /
2 Windows ObserverUnInstall

Configuration

Ethernet CF

WindowsObserver I IIConfiguration

bankCF /RS232/Ethernet

AI / AO / DI / DO / MATH

- / -&

53

CF RS232Ethernet

CF RS232Ethernet

.prj

Cancel

OK

54

CF card CF
Ethernet
RS232 RS232/422/485

CF 1pcEthernet RS232/422/485

5.2 Ethernet
Ethernet
255 1024 AI / Math / DO
/DI / /

55

Ethernet
1IP

2Setup.exe

3 Eternet
4.4 IP

PC

0.0.0.0
IP IP
IP
IP IP
4 UTPCat.5

PC/LAN/HUB 100
100 100
5
a.Crossover
b.HUB Cat.5

Cat.5

CDR18-LAN/HUB

CDR18-PC/Notebook

RJ-45

RJ-45

RJ-45

RJ-45

PIN

PIN

PIN

PIN

1 Tx+

1 Rc+

1 Rx+

3 Tx+

2 Tx-

2 Rc-

2 Rc-

6 Tx-

3 Rc+

3 Tx+

3 Tx+

1 Rc+

6 Rc-

6 Tx-

6 Tx-

2 Rc-

56

6
LED
LINK LED
LED PC/HUB
LED PC/HUB
TX/RX
LED

LED
7

Observer IIConfiguration
.prj

P.54Boiler

Ethernet

57

Ethernet

IP

?Y/N
Yes

AI

/
RJ45 LED
IP
IP IP
IP

58

5.3 RS232RS485RS422
RS485
247 1024 AI / Math / DO /DI
/ /
1 RS232 DB9M Port
2 RS232 232
USB 232
3 2.5 RS232/RS485/RS422 RS232
4 4.4 RS232
,,
RS232

5Observer IIConfiguration

6 RS232

RS232

7 RS232

59

8Node adderss1

OK
?Y/N

9Yes
10

AI

11

12 RS232
RS232

13 RS485/422 RS485

14 SNA-10ARS485 232 SNA-10A


SNA-10A SNA-10A Dip Switches
15 1000

16 RS232/485/422

60

Device usage
Device status
17 RS232

18
,,

61

5.4 CF
1 CF CF

2 CF
CF
/
3 CF USB
CF
CF
CF Windows Xp
Windows 98 / 2000 / ME / NT CF

4 CF
CF
5Observer I IIConfiguration

P.54Boiler

6 CF

62

8OK?Y/N
Yes
CF

AI

10 CF

aCF CF
IOdat Recorder.cfg
2~9
b CF 5~9

63

5.5 Real-Time Viewer

Real-Time Viewer

Tag Tag

abType
Setpoint
pop P.65
Real-Time
Viewer

64


TypeHiAlarm
SourceAI1
ActiveTime12/12/200594959AM
Value23.8

Ethernet

C:\Observer

1 Real-Time Viewer
2
3Observer II

C Observer II
Real-time.prj

65

STMP server Port 25


Internet/email Port STMP port

SMTP server

HostPort25

Ethernet

60 S 60

Bank 1 ~Bank 4
Modbus_TCPModbus_RS232
P.55
Ethernet 502
502
Ethernet Modbus_TCP

66

5.6 DDE
DDE
DDEDynamic Data Exchange Microsoft Windows
Windows Windows

DDE Excel
Excel
DDE Excel
Rela-Time Viewer
Z DDE Excel DCreat DDE link
in Excel

67

DDE Excel

DDE_ DDE

C Desktop
DDE_Excel
Office DDE Excel
Officee Office

Office DDE

Update Excel DDE DDE Eecel

DDE
RealTime_ViewerTagServer!_AI1
ApplicationRealTime_Viewer
TopicTagService
Tag nameAI1

68

_ tag name
Windows DDE AI/DI/DO/

Excel ERROR
tag
NAMENAMEAI1Tolz2.DO2..DI1..Cont4..
NAME

RealTime viewerYY
Excel
1 RAM DDE Excel

69

DDE
DDE Excel
PLCSCADA Visual Basic
PLC PLC DDE Excel
TM
PLC PLC DDE
SCADA DDE
SCADA
DDE Allen-Bradley SLC 5/03 PLC Excel
TaskWrite a block of data10 floating pointsfrom to PLC
Name of the Excel fileReports.XLS
Data SourceD37 to D 46data in total 10 cells
TargetPLCStarting adderss F8
User RSLinx to configure PLC and DDE link
DDE topic name in RSLinxDDE REPORTS
Sub Block_Write()
'open dde link: testsol=DDE Topic

This is comment only

RSIchan = DDEInitiate("RSLinx", "DDE_REPORTS")


'write data thru channel This is comment only
DDEPoke RSIchan, "F8:2,L10", Range("[Reports.XLS]PROCESS!D37:D46")
'close dde link This is comment only
DDETerminate (RSIchan)
End Sub

70

DDE Allen-Bradley SLC 5/03 PLC Excel


Task: Read a block of data (5 integers) from PLC to Excel
Name of the Excel file = Reports.XLS
Data Source: PLC, Starting address= N7:30
Target cells in Excel= A7 to A11
User RSLinx to configure PLC and DDE link
DDE topic name in RSLinx= DDE_REPORTS

Sub Block_Read()
'open dde link: testsol=DDE Topic

This is comment only

RSIchan = DDEInitiate("RSLinx", "DDE_REPORTS")


'get data and store in data variable This is comment only
data = DDERequest(RSIchan, "N7:30,L5,C1")
'Paste data into selected range This is comment only
Range("[Reports.XLS]DDE_Sheet!A7:A11").Value = data
'close dde link

This is comment only

DDETerminate (RSIchan)
End Sub

SCADAAllenBradley RSVIEW 32 DDE


Real Time
tag data
=RealTime_Viewer|TagService!_AI1
Application = RealTime_Viewer
Topic = TagService
Tag name = _AI1 (Please observe underscore before the name of the tag)
71

SCADA RSVIEW32 SCADA DDE


RSLinx

1) SCADA
2) SystemNodeselect DDE server as data source
3) NameCDR18CDR18
4) ApplicationRealTime_Viewer
5) TopicTagServer
6) Check enable in the box. DDE server source
7)
8) ( tag )
9) Select CDR18 at the NODE
10) tag
AI1_AI1
_AI _
11) tag () DDE
DDE Valid
1)Tag monitor

72

6.
1

Q / 0.0072*h *60
h mbar / 0~30 mbar
4.1 AI1
Level 1
XXXXXXX

1 S
0.00
1.000
Current
mA
Range4.0~20.0
Scale
mbar
Low0.00
High30.00
Math1
Level 1
XXXXXXX

1 S
0.0072*AI1^2.5*60
1 /min
Low0.0
High2200.0

2 ~ 800 1700
~

8 0

17 0

73

8 1

8 0

74

7. FAQs
Q1AIAO scale low scale high

A1 low scale 199991999.9199.99


19.9991.99990.19999
high scale 455364553.6455.3645.536
4.55360.45536
low scale 32768 3276.8 327.68
32.7683.27680.32768
high scale 327673276.7327.6732.767
3.27670.32767

Q2 Ethrenet Cat.5 RJ45


A2 100 100 Hub

Q3Ethernet
A330

Q4
A4-Toshiba CR2032 3.0V /220mAH Real time

Q5 Real Time Clock


A5

10~40
18
0 50
52
-10 60
107
75

Q6
A6

FDA 21 CFR part 11 2.2


30 Adminstrator
Supervisor Operator
Supervisor
Operator
Q7 Boot ROM Ethernet CF

A7Boot ROM BootROM BT181 BootROM


BT182 FDA21 CFR part 11
BootROM Ethernet CF BootROM
Q8
A8
Observer FTP EmailObserver
20MB

Q9
A91 V1.20
V1.20
V1.20
DOC
2 CF
DOC
Q10
A10

Q11 AIAODIDO 24V DC


A11 6 IO

76

Q12 CF
A12 256MB 1GB CF
SanDisk
Q13
A13 18

Q14 CF
A14 8MB
CF 3.11
Q15
A15
CF

Q16
A16AO-
6 AI / AO / DI / DO

3 AO183I4~20mA 3 AO183V
0~10V

Q17 OPC server ?


A17 CDR18 OPC server DDE
PLCSCADA 5.5 DDE

Q18
A18 TCP/IP RS232/422/485 Modbus RTU

Q19
A19
1Ethernet 255 IP
2RS485247

77

Q20
A20 1024
I/O AIDIDO AO
6 170
Q21

A21
RESET
)-()
RESET

Q22 AI JUMP DIP


Switches
A22 Jump DIP Switches Observer

Q23 Ethernet
A23 HUB- Cat.5 RJ45
-Cat.5 RJ45
Q24CF
A24 CF 6
CF
CF

32MB

256MB

1GB

30

240

960

10

300

2400

9600

120

3600

28800

115200

Q25
A25 36 (
) 36
Q26
A26
78


) Historical
)
) Historical Excel Excel

Q27
A276 ()6 ()18 ()
Q28DI
A28 30 pulses/(0.5Hz)
Pulse 4~20mA ( AI)
Q29

A29
Real time viewer
Histroical viewer--observerI & observer II PC software manual
1.1.4 observer
historical
real-time C:/Observer C Observer

Q30
A30.dat.idx.lst CObserver
histroicalrealtimeRecorder.cfg
histroicalrealtime

79

Q31
A31recorder.cfgIO.dat Email
( CObserver/historical )
Q32CDR18
A32 AP181 6 24VDC

Q33 RS232/RS422/RS485/Ethernet

A33 5.1
5.2 Ehernet 5.3 RS232RS422RS485

Q34 Excel CSV Excel

A34
Excel
Excel

Q35 pulses
A35 DI() pulses

DI
High 1
1
65535
DI pulses 30 pulses(0.5 Hz)
Pulse 4~20mA

80


:07-3221777 :07-3157301
: 182
: chunde88@ms51.hinet.net
: http://www.chunde.com.tw

You might also like