Professional Documents
Culture Documents
is one of the original and leading manufactures of Fire Alarm cables in the world. Security and Alarm cables are a vital part of the building and construction industries. Security and FireAlarm cables have been one of the most trusted names in the Security industry. offers the broadest line of fire alarm cables in the industry! Our fire alarm cables are designed to meet Conventional and Addressable system specifications. also offers Circuit Integrity fire alarm cables. For more detailed information on our fire alarm cables, contact our Customer Service Department at , or e-mail us at: . Information can also be found on our website:
Mini Index
Power-Limited Cables
FPLR/ Unshielded 48 FPLR/ Shielded 49 FPL- Low Cap/ Unshielded & Shielded 50 FPL/ One and Two Conductor 51 FPLP/ Unshielded 52 FPLP/ Shielded 53 FPLP/ Shielded Data Grade53
Circuit Integrity
Circuit Integrity in Conduit (CIC)/ Shielded Circuit Integrity in Conduit (CIC)/ Unshielded Circuit Integrity (CI)/ Shielded Circuit Integrity (CI)/ Unshielded 57 58 59 60
Over 95% of West Penn Wire cables are RoHS Compliant. For a detailed specification on individual products, contact our engineering department.
47
Description:
ASTM bare copper PVC insulation Twisted pair or cabled construction Overall PVC jacket
Applications:
Indoor for:
Audio Circuits Control Circuits Initiating Circuits Notification Circuits
Rating:
NEC Type FPLR (UL) or (ETL)us Listed Meets 300V requirements as specified in the NEC Flame Rating: UL1666
Catalog No. No. of Cond. Conductor Insulation Type & Type & Shielding Jacket Type Nom. D.C.R Thickness & Thickness Inches Inches Nom. O.D. Inches NEC Type
1 Pair 4
18 AWG Solid
6.5 /Mft
PVC .010 PVC .010 PVC .010 PVC .010 PVC .012 PVC .012 PVC .012 PVC .010 PVC .012 PVC .012
None
PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 PVC .015
.146
29 pf/ft*
RD, BK, WH, YE RD, BK, WH, YE RD, BK, WH, YE Red RD, BK, BL, WH, YE Red
18 AWG Solid
6.5 /Mft
None
.178
29 pf/ft*
16 AWG Solid
4.1 /Mft
None
.155
32 pf/ft*
16 AWG Solid
4.1 /Mft
None
.203
32 pf/ft*
14 AWG Solid
2.6 /Mft
None
.195
35 pf/ft*
14 AWG Solid
2.6 /Mft
None
.240
35 pf/ft*
12 AWG Solid
1.8 /Mft
None
.225
45 pf/ft*
Red
16 AWG Strd.
4.1 /Mft
None
.155
32 pf/ft*
Red
994S
New
14 AWG Strd.
2.6 /Mft
None
.195
35 pf/ft*
Red
998S
New
12 AWG Strd.
1.8 /Mft
None
.225
45 pf/ft*
Red
Special Notes:
Selected Plenum Versions see pages 52 Selected Indoor/Outdoor Aquaseal Water Resistant Versions see pages 43. Orange rip cord under jacket
48
Applications:
Indoor for:
Audio Circuits Control Circuits Initiating Circuits Notification Circuits
Description:
ASTM bare copper PVC insulation Twisted pair or cabled construction Overall shield 100% coverage of aluminum polyester foil binders as required with TC drain wire Overall PVC jacket
Rating:
NEC Type FPLR (UL) or (ETL)us Listed Meets 300V requirements as specified in the NEC Flame Rating: UL1666
Shielding &% Jacket Type Coverage & Thickness Inches Nom. O.D. Inches NEC Type Nom. Capacitance Jacket Color
22 AWG Solid
17.5 /Mft
PVC .010 PVC .010 PVC .010 PVC .010 PVC .010 PVC .012 PVC .012`
Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100%
PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 PVC .015 PVC .015
.146
54 pf/ft* 97 pf/ft** 73 pf/ft* 133 pf/ft** 73 pf/ft* 133 pf/ft** 82 pf/ft* 148 pf/ft** 82 pf/ft* 148 pf/ft** 84 pf/ft* 151 pf/ft** 96 pf/ft* 173 pf/ft**
Red
18 AWG Solid
6.5 /Mft
.149
Red
18 AWG Solid
6.5 /Mft
.182
16 AWG Solid
4.1 /Mft
.160
16 AWG Solid
4.1 /Mft
.207
14 AWG Solid
2.6 /Mft
.201
Red
12 AWG Solid
1.8 /Mft
.230
Red
* Capacitance between conductors. ** Capacitance between one conductor and the other connected to the shield
Color Code
1.Black, 2. Red, 3. Brown, 4. Blue
Special Notes:
Selected Plenum Versions see pages 53 Selected Indoor/Outdoor Aquaseal Water Resistant Versions see pages 44 Orange rip cord under jacket
All Cables
49
Applications:
Indoor data cable for:
Data Circuits Addressable Systems Initiating Circuits Notification Circuits Standard spool size 1000ft.
Nom. O.D. Inches NEC Type Nom. Capacitance Jacket Color
Rating:
NEC Type FPL (UL) or (ETL)us Listed Meets 300V requirements as specified in the NEC Flame Rating: UL1685
Catalog No. No. of Cond. Conductor Insulation Type & Type & Shielding Jacket Type Nom. D.C.R Thickness & Thickness Inches Inches
1 Pair 4 1 Pair
18 AWG Polyolefin Solid .015 6.5 /Mft 18 AWG Solid Polyolefin .015 6.5 /Mft 16 AWG Polyolefin Solid .015 4.1 /Mft
None
.182
16 pf/ft*
Red
None
.230
16 pf/ft*
Red
None
.223
18 pf/ft*
Red
18 AWG Solid Polyolefin 6.5 /Mft .015 16 AWG Polyolefin Solid .015 4.1 /Mft 14 AWG Polyolefin Solid .020 2.6 /Mft
.210
Red
.226
Red
.262
Red
Color Code
All Cables
1.Black, 2. Red, 3. Brown, 4. Blue
* Capacitance between conductors. ** Capacitance between one conductor and the other connected to the shield
JACKET: Red
Special Notes:
Selected Plenum Versions see pages 53 Orange rip cord under jacket
50
Applications:
Indoor for:
Power-Limited Protective Circuits
Rating:
NEC Type FPL (UL) or (ETL)us Listed Flame Rating: UL1685
Shielding Jacket Type & Thickness Inches Nom. O.D. Inches NEC Type Nom. Capacitance Jacket Color BK, GN, BN, WH, RD, OR, YE
Single Conductor
Catalog No. No. of Cond. Conductor Insulation Type & Type & Nom. D.C.R Thickness Inches
962
14AWG Solid
2.6 /Mft
PVC .020
None
--
.104
--
18 AWG Solid
6.5 /Mft
None
---
.104x.204
--
16 AWG Solid
4.1 /Mft
None
.115x.225
--
None
---
.128x.250
--
None
.146x.300
--
Colors
Jacket Colors
RD-Red, BK-Black WH- White, YE-Yellow, OR-Orange, BN-Brown
Do not forget that West Penn Wire offers a complete and comprehensive line of: Connectors Cable Assemblies Installation Kits Fiber Optic Accessories A/V Wall Plates
800-245-4964
51
Description:
ASTM bare copper Polymer alloy insulation Twisted pair or cabled construction Flexible plenum jacket
Applications:
Indoor within ducts,plenums and other spaces used for environmental air: Audio Circuits Control Circuits Initiating Circuits Notification Circuits
Rating:
NEC Type FPLP (UL) or (ETL)us Listed Meets 300V requirements as specified in the NEC Flame Rating: NFPA-262 Smoke & Flame Test
Catalog No. No. of Cond. Conductor Insulation Type & Type & Shielding Jacket Type Nom. D.C.R Thickness & Thickness Inches Inches
18 AWG Solid
6.5 /Mft
.010
None
.015
.142
29 pf/ft*
Red
18 AWG Solid
6.5 /Mft
.010
None
.015
.175
29 pf/ft*
Red
16 AWG Solid
4.1 /Mft
.010
None
.015
.161
32 pf/ft*
Red
16 AWG Solid
4.1 /Mft
.010
None
.015
.220
32 pf/ft*
Red
14 AWG Solid
2.6 /Mft
.012
None
.015
.191
35 pf/ft*
Red
14 AWG Solid
2.6 /Mft
.012
None
.015
.252
35 pf/ft*
Red
12 AWG Solid
1.8 /Mft
.012
None
.015
.225
45 pf/ft*
Red
Special Notes:
Plenum Installation Precautions see Technical Reference Section Page 192
Color Code
All Cables
1.Black, 2. Red, 3. Brown, 4. Blue
JACKET: Red
52
Applications:
Indoor within ducts,plenums and other spaces used for environmental air: Audio Circuits Control Circuits Initiating Circuits Notification Circuits
Description:
ASTM bare copper Polymer Alloy insulation Twisted pair or cabled construction Overall shield 100% coverage of aluminum polyester foil with TC drain wire Flexible plenum jacket
Rating:
NEC Type FPLP (UL) or (ETL)us Listed Meets 300V requirements as specified in the NEC Flame Rating: NFPA-262 Smoke & Flame Test
Nom. O.D. Inches NEC Type Nom. Capacitance Jacket Color
Conductor Insulation Shielding Type & Type & & Jacket Type Nom. D.C.R Thickness % Coverage & Thickness Inches Inches
18 AWG Solid
6.5 /Mft
.010
Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100%
.015
.148
54 pf/ft* 97 pf/ft** 54 pf/ft* 97 pf/ft** 61 pf/ft* 110 pf/ft** 61 pf/ft* 110 pf/ft** 84 pf/ft* 151 pf/ft** 96 pf/ft* 173 pf/ft**
Red
18 AWG Solid
6.5 /Mft
.010
.015
.178
Red
16 AWG Solid
4.1 /Mft
.010
.015
.166
Red
16 AWG Solid
4.1 /Mft
.010
.015
.210
Red
14 AWG Solid
2.6 /Mft
.012
.015
.198
Red
12 AWG Solid
1.8 /Mft
.012
.015
.224
Red
.012
.015
.165
Red
16 AWG Solid
4.1 /Mft
.015
.015
.184
Red
^ - Data grade versions for addressable systems contain Low Loss Insulation and Overall Flexible Plenum Jacket.
* Capacitance between conductors. ** Capacitance between one conductor and the other connected to the shield
Color Code
All Cables
1.Black, 2. Red, 3. Brown, 4. Blue
Special Notes:
Plenum Installation Precautions see Technical Reference Section Page 192
JACKET: Red 53
Indoor for:
Audio Circuits Control Circuits Initiating Circuits Notification Circuits
Rating:
NEC Type NPLF (UL) or (ETL)us Listed Meets 150V requirements as specified in the NEC Flame Rating: UL1685
Catalog No. No. of Cond. Conductor Insulation Type & Type & Shielding Jacket Type Nom. D.C.R Thickness & Thickness Inches Inches Nom. O.D. Inches NEC Type
1990
1 Pair
16 AWG Solid
4.1 /Mft
None
PVC .037
.252
--
Red
1994
1 Pair
14 AWG Solid
2.6 /Mft
None
PVC .037
.278
--
Red
Special Notes:
Selected Plenum Versions see pages 56 Orange rip cord under jacket
Color Code
All Cables
1.Black, 2. Red
JACKET: Red
54
Shielded
Description:
ASTM bare copper PVC insulation with Nylon Twisted pair or cabled construction Overall shield 100% coverage of aluminum polyester foil with TC drain wire Overall PVC jacket
Rating:
NEC Type NPLF (UL) or (ETL)us Listed Flame Rating: UL1685 Standard spool size 1000ft.
Catalog No. No. of Cond. Conductor Insulation Shielding Jacket Type Type & Type & & & Nom. D.C.R Thickness % Coverage Thickness Inches Inches Nom. O.D. Inches NEC Type Nom. Capacitance Jacket Color
1975
1 Pair
18 AWG Solid
6.5 /Mft
1991
1 Pair
16 AWG Solid
4.1 /Mft
1995
1 Pair
14 AWG Solid
2.6 /Mft
1997
14 AWG Solid
2.6 /Mft
PVC .016 Nylon .005 PVC .016 Nylon .005 PVC .016 Nylon .005 PVC .016 Nylon .005 PVC .016 Nylon .005
PVC .037
.244
52 pf/ft* 94 pf/ft**
Red
PVC .037
.264
Red
PVC .037
.284
Red
PVC .042
.388
Red
1999
1 Pair
12 AWG Solid
1.8 /Mft
PVC .042
.328
Red
* Capacitance between conductors. ** Capacitance between one conductor and the other connected to the shield
Color Code
All Cables
1.Black, 2. Red, 3. Brown, 4. Blue
Special Notes:
Selected Plenum Versions see pages 56 Orange rip cord under jacket
JACKET: Red
55
Description:
ASTM bare copper Fluoroplymer insulation Twisted pair or cabled construction Unshielded and Shielded Versions (Shielded versions) 100% coverage of aluminum polyester foil with TC drain wire Overall fluoropolymer jacket
Applications:
Indoor for:
Audio Circuits Control Circuits Initiating Circuits Notification Circuits
Rating:
NEC Type NPLFP (UL) or (ETL)us Listed Meets 150V requirements as specified in the NEC Flame Rating: NFPA-262 Smoke & Flame Test
Catalog No. No. of Cond. Conductor Insulation Shielding Type & Type & & Jacket Type Nom. D.C.R Thickness % Coverage & Thickness Inches Inches Nom. O.D. Inches NEC Type
18 AWG Solid
6.5 /Mft
Fluoropolymer .020 Fluoropolymer .020 Fluoropolymer .020 Fluoropolymer .020 Fluoropolymer .020
.010
.185
--
Red
18 AWG Solid
6.5 /Mft
.010
.195
--
Red
16 AWG Solid
4.1 /Mft
.010
.214
--
Red
14 AWG Solid
2.6 /Mft
.010
.210
--
Red
14 AWG Solid
2.6 /Mft
.010
.220
--
Red
Color Code
All Cables
1.Black, 2. Red
JACKET: Red
56
Shielded
Description:
ASTM bare copper Ceramifiable Silicon Rubber (CSR) Insulation Twisted pair or cabled construction Overall shield 100% coverage of aluminum polyester foil with TC drain wire Overall FRPE Low-Smoke, Non-Halogen Jacket
Rating:
NEC Type FPLR (UL) Listed Meets 300V requirements as specified in the NEC - 105C Flame Rating: UL1666, UL2196 - 2 Hour Flame Test ( in conduit only)
Nom. O.D. Inches NEC Type Nom. Capacitance Jacket Color
Conductor Insulation Shielding Type & Type & & Jacket Type Nom. D.C.R Thickness % Coverage & Thickness Inches Inches
16 AWG 7x24
4.0 /Mft
CSR .035 CSR .035 CSR .035 CSR .035 CSR .035 CSR .035
Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100%
FRPE .056 FRPE .056 FRPE .056 FRPE .056 FRPE .056 FRPE .056
.37
22pf/ft*
Red
16 AWG Solid
4.0 /Mft
.36
20pf/ft*
Red
16 AWG Solid
4.0 /Mft
.41
16pf/ft*
Red
14 AWG 7x22
2.5 /Mft
.41
26pf/ft*
Red
14 AWG Solid
2.5 /Mft
.38
23pf/ft*
Red
12 AWG 7x20
1.6 /Mft
.44
27pf/ft*
Red
Color Code
All Cables
Black, Red- 4 or more are Black and numbered
Special Notes:
CSR- Ceramifiable Silicon Rubber FRPE- Flame Retardant Polyethylene
JACKET: Red
57
Applications:
Indoor for:
Circuit Integrity Fire Alarm Circuit Integrity Survivability Survivability from attack by fire
Rating:
NEC Type FPLR (UL) Listed Meets 300V requirements as specified in the NEC - 105C Flame Rating: UL 1666, UL2196 - Two Hour Flame Test ( in conduit only)
Catalog No. No. of Cond. Conductor Insulation Type & Type & Shielding Jacket Type Nom. D.C.R Thickness & Thickness Inches Inches Nom. O.D. Inches
16 AWG 7x24
4.0 /Mft
None
.37
16pf/ft*
Red
16 AWG Solid
4.0 /Mft
None
.35
15pf/ft*
Red
14 AWG 7x22
2.5 /Mft
None
.40
18pf/ft*
Red
14 AWG Solid
2.5 /Mft
None
.38
17pf/ft*
Red
Special Notes:
CSR- Ceramifiable Silicon Rubber FRPE- Flame Retardant Polyethylene
Color Code
All Cables
Black, Red
JACKET: Red
58
Description:
ASTM bare copper Ceramifiable Silicon Rubber (CSR) Insulation Twisted pair or cabled construction Overall shield 100% coverage of aluminum polyester foil with TC drain wire Overall FRPE Low-Smoke, Non Halogen Jacket
Rating:
NEC Type FPLR-CI (UL) Listed Meets 300V requirements as specified in the NEC - 105C Flame Rating: UL1666, UL2196 - 2 Hour Flame Test
Nom. O.D. Inches NEC Type Nom. Capacitance Jacket Color
Conductor Insulation Shielding Type & Type & & Jacket Type Nom. D.C.R Thickness % Coverag & Thickness Inches Inches
5320FM 5322FM 5300FM 5302FM 5220FM 5222FM 5200FM 5120FM 5122FM 5100FM 5020FM 5022FM
18 AWG Solid
5.9 /Mft
CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034
Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100% Al. Foil 100%
FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045
.31
-CI
27pf/ft*
Red
18 AWG Solid
5.9 /Mft
.36
-CI
27pf/ft*
Red
18 AWG 7x26
5.9 /Mft
.32
-CI
27pf/ft*
Red
18 AWG 7x26
5.9 /Mft
.37
-CI
27pf/ft*
Red
16 AWG Solid
4.0 /Mft
.33
-CI
31pf/ft*
Red
16 AWG Solid
4.0 /Mft
.38
-CI
31pf/ft*
Red
16 AWG 7x24
4.0 /Mft
.35
-CI
31pf/ft*
Red
14 AWG Solid
2.5 /Mft
.36
-CI
33pf/ft*
Red
14 AWG Solid
2.5 /Mft
.41
-CI
33pf/ft*
Red
14 AWG 7x22
2.5 /Mft
.38
-CI
33pf/ft* 37pf/ft*
Red
12 AWG Solid
1.6 /Mft
.39
-CI
Red
12 AWG Solid
1.6 /Mft
.46
-CI
37pf/ft*
Red
59
Unshielded
Rating:
NEC Type FPLR-CI (UL) Listed Meets 300V requirements as specified in the NEC - 105C Flame Rating: UL 1666, UL2196- Two Hour Flame Test
Catalog No. No. of Cond. Conductor Insulation Type & Type & Shielding Jacket Type Nom. D.C.R Thickness & Thickness Inches Inches Nom. O.D. Inches
18 AWG Solid
5.9 /Mft
CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034 CSR .034
None
FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045 FRPE .045
.31
-CI
17pf/ft*
Red
18 AWG Solid
5.9 /Mft
None
.35
-CI
17pf/ft*
Red
16 AWG Solid
4.0 /Mft
None
.33
-CI
19pf/ft*
Red
16 AWG Solid
4.0 /Mft
None
.38
-CI
19pf/ft*
Red
14 AWG Solid
2.5 /Mft
None
.36
-CI
21pf/ft*
Red
14 AWG Solid
2.5 /Mft
None
.41
-CI
21pf/ft*
Red
12 AWG Solid
1.6 /Mft
None
.39
-CI
23pf/ft*
Red
12 AWG Solid
1.6 /Mft
None
.45
-CI
23pf/ft*
Red
Special Notes:
CSR- Ceramifiable Silicon Rubber FRPE- Flame Retardant Polyethylene
Color Code
All Cables
Black, Red- 4 or more are Black and numbered
JACKET: Red
60