Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications.

Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensors & Sensor Modules

PYROELECTRIC INFRARED SENSORS & SENSOR MODULES

Murata Manufacturing Co., Ltd.

Cat.No.S21E-3

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

CONTENTS
Part Numbering 1 2 3 4 Dual Type Pyroelectric Infrared Sensor IRA-E700 Series Quad Type Pyroelectric Infrared Sensor IRA-E900 Series Quad Type Pyroelectric Infrared Sensor IRA-E940ST1 Series Temperatue Compensation Single Type Pyroelectric Infrared Sensor IRA-E420 Series Pyroelectric Infrared Sensor IRA Series Characteristics Data 5 Pyroelectric Infrared Sensor Module IMD Series 5 6 11 13 1 2 3 4

Notice

Recycled Paper

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

o Part Numbering
Pyroelectric Infrared Sensor
(Global Part Number) IR q qProduct ID wType eCharacteristics rIndividual Specification Code * Global Part Number shows only an example which might be different from actual part number. * "eCharacteristics" and "rIndividual Specification Code" might have different digit number from actual Global Part Number. Aw E710ST e 1 r

Sensor Module
(Global Part Number) IM q qProduct ID wType eCharacteristics rIndividual Specification Code * Global Part Number shows only an example which might be different from actual part number. * "eCharacteristics" and "rIndividual Specification Code" might have different digit number from actual Global Part Number. Dw B101e 01 r

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensors


Dual Type Pyroelectric Infrared Sensor IRA-E700 Series

Pyroelectric infrared sensors, IRA series, exhibit high sensitivity and reliable performance made possible by Murata's ceramic technology and Hybrid IC technique expertise developed over many years. IRA-E700 series realizes cost benefits and higher performance with a new infrared sensor element of improved material parameters and fabrication. IRA-E700 series is available in two types. IRA-E710ST0 has enhanced immunity to RFI (Radio Frequency Interference).

! Features
1. High sensitivity and excellent S/N ratio 2. High stability to the temperature change 3. Slight movement can be detectable. 4. High immunity to the external noise (Vibration, RFI etc.) 5. Custom design is available. 6. Higher in cost-performance

! Dimensions & Circuit Diagrams


4.70.1 45 3.70.1 9.2 45 0.45 0.05
5. 0

! Applications
1. Security 2. Lighting appliances 3. Household or other appliances

11.02 Specified on the bottom of stem

!Rating (25C)
Part Number Responsivity (500K, 1Hz, 1Hz) Field of View Optical Filter Electrode Supply Voltage Operating Temperature Storage Temperature IRA-E700ST0 IRA-E710ST0
d s g

4.3mVp-p (Typ.) 1=2=45 5m long-pass (2.0Z1.0mm)Z2 2 to 15V -40 to 70D -40 to 85D

3.6 4.7
05 0.

General Tolerance : 0.2 (in mm)

Pyroelectric element 2.0 1.0 1.0 1.0

(in mm)

IRA-E700ST0
RG

d s g

IRA-E710ST0

d s RG g

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensors


Quad Type Pyroelectric Infrared Sensor IRA-E900 Series 2

Pyroelectric infrared sensors, IRA series, exhibit high sensitivity and reliable performance made possible by Murata's ceramic technology and Hybrid IC technique expertise developed over many years. IRA-E900 series realizes cost benefits and higher performance with a new infrared sensor element of improved material parameters and fabrication. IRA-E900 series is available in two types. IRA-E910ST1 has enhanced immunity to RFI (Radio Frequency Interference).

! Features
1. High sensitivity and excellent S/N ratio 2. High stability to the temperature change 3. Slight movement can be detectable. 4. Non directional sensing with wide F.O.V. 5. High immunity to the external noise (Vibration, RFI etc.) 6. Custom design is available. 7. Higher in cost-performance

! Dimensions & Circuit Diagrams


4.70.1 41 9.2 41 0.45 0.05 11.02 3.6 4.7

! Applications
1. Security 2. Lighting appliances 3. Household or other appliances

Specified on the bottom of stem

5.080.05

! Rating (25C)
Part Number Responsivity (500K, 1Hz, 1Hz) Field of View Optical Filter Electrode Supply Voltage Operating Temperature Storage Temperature IRA-E900ST1 IRA-E910ST1
d s g General Tolerance : 0.2 (in mm)

3.3mVp-p (Typ.) 1=2=41 5m long-pass (1.1Z1.1mm)Z4 3 to 15V -25 to 55D -40 to 85D

Pyroelectric element 1.1 1.0 1.1

1.1 1.0 1.1

(in mm)

IRA-E900ST1

W Y Y W W Y Y W

Y W W Y Y W W Y

s RG

IRA-E910ST1
d
W Y Y W W Y Y W Y W W Y Y W W Y

s RG

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensors


Quad Type Pyroelectric Infrared Sensor IRA-E940ST1 Series

Pyroelectric infrared sensors, IRA series, exhibit high sensitivity and reliable performance made possible by Murata's ceramic technology and Hybrid IC technique expertise developed over many years. IRA-E940ST1 realizes cost benefits and higher performance with a new infrared sensor element of improved material parameters and fabrication. IRA-E940ST1 which has quad elements and 2 outputs will detect the human body more correctly with OR/AND logic circuit.

! Features
1. High sensitivity and excellent S/N ratio 2. High stability to the temperature change 3. High immunity to the external noise (Vibration, RFI etc.) 4. Higher in cost-performance 5. Custom design is available.

! Dimensions & Circuit Diagrams


4.70.1 50 9.2 55 0.45 0.05 11.02 3.6 4.7

! Applications
1. Security 2. Lighting appliances 3. Household or other appliances

! Rating (25C)
Part Number Responsivity (500K, 1Hz, 1Hz) Field of View Optical Filter Electrode Supply Voltage Operating Temperature Storage Temperature IRA-E940ST1 3.3mVp-p (Typ.) 1=55, 2=50 5m long-pass (1.35Z1.0mm)Z4 2 to 15V -25 to 55D -40 to 85D
(Y) W

Specified on the bottom of stem

5.080.05

s1 d g s2

General Tolerance : 0.2 (in mm)

Pyroelectric element
(Y) W Y (W) Y (W)

1.35 0.3 1.35

1.0 0.8 1.0

(in mm)

d RG RG s2 s1 g

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensors


Temperature Compensation Single Type Pyroelectric Infrared Sensor IRA-E420 Series

Single type pyroelectric infrared sensors IRA-E420 series, have a temperature compensation element. They are suitable for flame detection and gas detection.

! Features
1. High stability against abrupt ambient temperature change 2. High immunity to the external noise (Vibration, RFI etc.) 3. Custom design is available with varying optical filter.

! Applications
Part Number IRA-E420S1 IRA-E420QW1 Optical Filter Silicon 4.3m band-pass Applications 1-15m infrared detection Flame detection

! Dimensions & Circuit Diagrams


2.40.1 17 9.2 17 0.45 0.05 11.02 3.6 4.9

Specified on the bottom of stem

5.080.05

s g Pyroelectric element 1.6

General Tolerance : 0.2 (in mm)

(in mm)

d s g

RG

! Rating (25C)
Part Number Responsivity (500K, 1Hz, 1Hz) Field of View Optical Filter Electrode Supply Voltage Operating Temperature Storage Temperature
* 700K, 5Hz, 1Hz

IRA-E420S1 3.4mVp-p (Typ.) 1=2=17 Silicon 1.6mm 3 to 15V -25 to 70D -30 to 100D

IRA-E420QW1 1.3mVp-p (Typ.)* 4.3m band-pass

-25 to 55D

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensor IRA Series Characteristics Data


! Spectral Response of Window Materials
Wave length (m) 2.5 100 3.0 4.0 5.0 6.0 7.0 8.0 10.0 12.0

5m Long-Pass Filter 80 4.3m Band-Pass Filter

Transmittance (%)

60

40 Silicon Filter

20

7m Long-Pass Filter

0 4000 3500 3000 2500 2000 1800 Wave number (cm-1) 1600 1400 1200 1000 800

! Frequency Characteristics
10 Relative Responsivity (RV)

1.0

10 Chopping Frequency (Hz)

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensor IRA Series Characteristics Data


! Test Method of Sensitivity
Lock-in Amplifier (1Hz) 140mm W5V

Black Body 500K

d s

47k W 22F

g Mechanical Chopper 1Hz Infrared Sensor

Oscilloscope

! Typical Application Circuit (Human detection)


3 Terminal Regulater 78L05 260k B222K 220k 10M NJM 2903M 100k 4 2 1S184 R 6 7
W W10

9Y15

100k 100k 2SD596

4
Photo Cuppler
W 100 W 100

B102K D S g 100k 1 B102K 120k 120k


W 4.7

LM358 B102K 10M B222K 1S184

330k 3.3 16V 100k


W

3 PD5555G

16V Relay 1k

16V

16V

100k LM358 330k B102K 220k 10 16V 16V C

5 B103K GND

TH=1.1ZC (F) Z R (M) second

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensor IRA Series Characteristics Data


! Fresnel Lens for Human Body Detection
PPGI0601

B' C'

16.3

m 3.0 C C 2.0 B D B D A A D' B' D' B' C' C' 3.0 1.0 2.0 3.0 4.0 5.0 m m 4.0 D, D' 3.0 22.5 Vertical Area 2.0 E' 1.0 30 1.0 E, E' 0 1.0 2.0 3.0 4.0 5.0 m C C' B B' A

D'

E'

1.0 16.0 11.64 R Horizontal Area 0

6.4 5.0 3.64

2.0 Cross-Sectional View 3.60 2.24 (in mm)

20.0 21.0

PPGI0902
Sensor Horizontal Area 7.7m Vertical Area

21.5

9m 2m 44.5

10

29.6 Sensor

10m

1m 1.6m 3.5m 10m

9m 51.5 56.5 7.7m

12

(in mm) 29.6R Lens plane 0.7max.

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensor IRA Series Characteristics Data

PPGI0626
23T0.2 12.9SR 21.4 19.4 A B C
12 .1

2 3.6 6 3

SR

Pyroelectric element

3 (in mm)

16.5

2.5m

Detection area on the floor


B : 60pitch C : 30pitch Y C1 C12 B1 B6 X C10 B5 C9 B4 B3 C5 B2 C4 Z C2

0.5m

2.2m C3 0.8m B 1 A B C A : 0 B : 21.8 C : 48 Y 2

C11

C8 C7

C6

Freshel lens are available upon request.

3 (m)

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensor IRA Series Characteristics Data


! Reliability Test
IRA-E700 series, IRA-E900 series
Item High Temperature Low Temperature Humidity Heat Cycle 100D for 500 hrs. Y40D for 500 hrs. 60D, 95% RH for 500 hrs. 20 times of following cycle. Y25D, 30min.eRoom temp., 30min.h gRoom temp., 30min.f55D, 30min. Apply vibration of amplitude of 1.5mm with 10 to 55Hz band to each of 3 Vibration Shock Soldering Heat Hermetic Sealing perpendicular directions for 60min. Apply shock of 100G sinewave by standard shock tester to each of 3 perpendicular directions. Immerse up to 3.0mm from can case in solder bath of 260T5D for 10T1 s. Conform to MIL-STD-202F chapter 112D, condition D. Immerse in fluorocarbon bath (FC-40) of 125T5D for 20 s. Conform to MIL-STD-202F chapter 208B. Solderability Immerse in rosin flax and Immerse up to 2.0 to 2.5mm from can case in solder bath of 230T5D for 5T0.5 s. Test Conditions Criteria After test completion, leave for three hours in normal humidity temperature conditions, and then measure. 1. External appearance: No significant damage. 2. Sensitivity: Tolerance within 20% deviation from original value. 3. Noise: Maximum tolerance W100mV of original value No generation of bubbles. More than 95% of the terminal should be covered by solder.

IRA-E420 series
Item High Temperature Low Temperature Humidity Heat Cycle 100D for 500 hrs. Y30D for 500 hrs. 60D, 95% RH for 500 hrs. 20 times of following cycle. Y25D, 30min.eRoom temp., 30min.h gRoom temp., 30min.f55D, 30min. Apply vibration of amplitude of 1.5mm with 10 to 55Hz band to each of 3 Vibration Shock Soldering Heat Hermetic Sealing perpendicular directions for 60min. Apply shock of 100G sinewave by standard shock tester to each of 3 perpendicular directions. Immerse up to 3.0mm from can case in solder bath of 260T5C for 10T1 s. Conform to MIL-STD-202F chapter 112D, condition D. Immerse in fluorocarbon bath (FC-40) of 125T5D for 20 s. Conform to MIL-STD-202F chapter 208B. Solderability Immerse in rosin flux and Immerse up to 2.0 to 2.5mm from can case in solder bath of 230T5D for 5T0.5 s. Test Conditions Criteria After test completion, leave for three hours in normal humidity temperature conditions, and then measure. 1. External appearance: No significant damage. 2. Sensitivity: Tolerance within 20% deviation from original value. 3. Noise: Maximum tolerance W100mV of original value No generation of bubbles. More than 95% of the terminal should be covered by solder.

10

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensor Modules


Pyroelectric Infrared Sensor Module IMD Series

Newly Developed Modules with Lower Power Consumption and Extra Features.
The IMD Series is comprised of an amplifier and high performance infrared sensor modules in compact, hermetically sealed metal can packages. Power consumption of the module is very low and a Fresnel lens is included in the module. Analog & Digital Output Model (IMD-B101-01) and Digital Output & Brightness Sensor (CdS) Input Model (IMD-B10201) are available for different applications.

! Features
1. With the fresnel lens, the sensor is able to detect the human body at a distance of 5m through angles of 119Z38 (Max.) 2. The modules have a compact size of 20.3Z12.6Z7.8mm. 3. The modules incorporate an amplifier and a single processing circuit. 4. They have outstanding reliability and EMI characteristics. 5. They have low power consumption.

! Dimensions

5
(3) (2) 7.62 10.8 12.6 4.7 35

! Applications
1. Automatic light switches 2. On/off controls for household appliances, industrial equipment and office equipment 3. Amusement devices (Games, Toys, etc.)

(4)

8.3 18.4 20.3

(1) Pyroelectric element 2Z1mm Dual element Specified on the bottom of stem

45 7.8 7.02 5.1

Pin No. IMD-B101-01 IMD-B102-01 (1) GND Analog Output Vcc Digital Output GND CdS Input Vcc Digital Output

!Block Diagram

(2) (3) (4)

0.450.05 15.24
IMD-B101-01 Analog Output

General Tolerance : 0.2 (in mm)

Sensor Amplifier Comparator

Gate Circuit Output Circuit

Digital Output

! Fresnel Lens
5.0 2-2

Stabilized Power Supply

Cds Input IMD-B102-01

16.5

21.5

22.5 IMD-FL01W (White) IMD-FL01G (Gray) 16.4

General Tolerance : 0.4 (in mm)

26.5

11

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Pyroelectric Infrared Sensor Module IMD Series


! Max. Rating (25C)
Max. Supply Voltage Operating Temp. Range Storage Temp. Range 5.5V Y10 to W50D (Without condensation) Y20 to W60D
52

! Detection Area (With Fresnel Lens)

! Rating (25C)
Items Supply Voltage Current Consumption Ready Period Active Period 2.6Y5.5V 30Y60A 50Y120A C-MOS 1mA (P1) (P2) 1.0Y3.0s F3.0s 5Y14m 1m 5m 119Z38 (Max.)
Vertical Area Horizontal Area

m 2.0

34

1.0
12.5

0 3.0 1.0 5.0m

Output Terminal Output Current Output Pulse Width Prohibited Time Wave Length Range Detection Length Without Lens With IMD-FL01W/G

2.0

m 2.0

Detection Range

1.0

15

0 3.0 1.0 5.0m

! Timing Chart (IMD-B101-01)

2.0

Analog Output

Digital Output

P1

! Typical Application (IMD-B102-01)


P2 78L05 500 LOAD 3 4 RLU1k 2 1 CdS 200 to 500k
W Y W Y

Prohibited Period

8Y15V

0.1100F

22Y220F

CdS Input is required to be Vcc 3.9W0.2V/Y0.4V or higer to operate. IMD-B101-01 generates analog output at Pin (2).

! Reliability Test
Item High Temperature Low Temperature Humidity Heat Cycle 60D for 500 hrs. Y20D for 500 hrs. 60D, 95% RH for 150 hrs. 20 times of following cycle. Y20D, 30min.eRoom temp., 30minh gRoom temp., 30min.f60D, 30min. Apply vibration of amplitude of 1.5mm with 10 to 55Hz band to each of 3 Vibration Shock Soldering Heat Hermetic Sealing perpendicular directions for 2 hrs. Apply shock of 30G sinewave by standard shock tester to each of 3 perpendicular directions for 5 times. Immerse up to 3.0mm from can case in solder bath of 260T5D for 10T1 s. Conform to MIL-STD-202F chapter 112D, condition D. Immerse in fluorocarbon bath (FC-40) of 125T5D for 20 s. No generation of bubbles. After test completion, leave for three hours in normal humidity temperature conditions, and then measure. 1. External appearance: No significant damage. 2. Sensitivity: Min. 70% of original value. 3. Current consumption: Within rated value. Test Conditions Criteria

12

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Notice
! Notice 1. Caution in design
(1) Please make sure that your product has been evaluated and confirmed against your specifications when our product is mounted to your product. (2) Be sure to provide an appropriate fail-safe function on your product to prevent a second damage that may be caused by the abnormal function or the failure of our product. (3) In case of outdoor use, suitable optical filter and water and humidity proof structure should be applied. (4) To prevent failure or malfunction, please use a stabilized power supply. (5) Please avoid using the sensor in the following conditions because it may cause failure or malfunction. (a) in such a fluid as water, alcohol etc. corrosive gas (SO2, Cl2, NOX etc.) or sea breeze (b) in high humidity (c) in a place exposed directly to sun light or headlight of automobile (d) in a place exposed to rapid ambient temperature change (e) in a place exposed directly to an air-conditioner or heat vent (f) strong vibrations (g) in a place exposed to strong electromagnetic field (h) in such a place where infrared ray is shaded (i) in any other place similar to the above (a) through (h)

2. Caution in mounting
(1) Soldering (a) Hand soldering should be applied. (b) Soldering should be done quickly as following.
Temperature of soldering iron : 350C Distance from can case 1Y3mm Over 3mm Period of time Within 3seconds per point Within 10seconds per point

(c) Soldering flux should be rosin flux and not contain more than 0.2wt% chlorine. Soldering flux should be removed after soldering. (2) Cleaning Soldering flux should be removed after soldering. Soldering flux may cause malfunction or degradation of character unless sufficiently cleaned.

3. Caution in handling and storage


(1) The optical filter of the sensor should not be scratched or soiled. (2) Strong shock should be avoided. (3) Electrostatics and strong electromagnetic field should be avoided. (4) The sensor should be kept on conductive sponge. (5) High temperature, high humidity, fluid such as water or alcohol etc., corrosive gas (SO2, Cl2, NOX etc.) and sea breeze should be avoided.

13

Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested to approve our product specification or to transact the approval sheet for product specification, before your ordering.

S21E3.pdf 03.2.17

Note:
1. Export Control For customers outside Japan Murata products should not be used or sold for use in the development, production, stockpiling or utilization of any conventional weapons or mass-destructive weapons (nuclear weapons, chemical or biological weapons, or missiles), or any other weapons. For customers in Japan For products which are controlled items subject to the Foreign Exchange and Foreign Trade Law of Japan, the export license specified by the law is required for export.

< <

>

>

2. Please contact our sales representatives or product engineers before using the products in this catalog for the applications listed below, which require especially high reliability for the prevention of defects which might directly damage to a third party's life, body or property, or when one of our products is intended for use in applications other than those specified in this catalog. q Aircraft equipment w Aerospace equipment e Undersea equipment r Power plant equipment t Medical equipment y Transportation equipment (vehicles, trains, ships, etc.) u Traffic signal equipment i Disaster prevention / crime prevention equipment o Data-processing equipment !0 Application of similar complexity and/or reliability requirements to the applications listed in the above 3. Product specifications in this catalog are as of January 2003. They are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. If there are any questions, please contact our sales representatives or product engineers. 4. Please read rating and CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc. 5. This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 6. Please note that unless otherwise specified, we shall assume no responsibility whatsoever for any conflict or dispute that may occur in connection with the effect of our and/or a third party's intellectual property rights and other related rights in consideration of your use of our products and/or information described or contained in our catalogs. In this connection, no representation shall be made to the effect that any third parties are authorized to use the rights mentioned above under licenses without our consent. 7. No ozone depleting substances (ODS) under the Montreal Protocol are used in our manufacturing process.

http://www.murata.com/
Head Office 2-26-10, Tenjin Nagaokakyo-shi, Kyoto 617-8555, Japan Phone: 81-75-951-9111 International Division 3-29-12, Shibuya, Shibuya-ku, Tokyo 150-0002, Japan Phone: 81-3-5469-6123 Fax: 81-3-5469-6155 E-mail: intl@murata.co.jp