LINTELS With standard lintels available in a comprehensive range of sizes and profiles as well as the facility to supply special lintels designed and manufactured to your specification, Wincro can provide the right lintel for virtually any application.

Flooring Systems

Ties & Restraints

Lintels

Windposts

Reinforcement

COMPANY PROFILE
Wincro Metal Industries is a long established company founded on the principles of innovative design, quality manufacture and outstanding customer service. Our steadfast commitment to those values over the years has firmly established Wincro as one of todays leading designers and manufacturers of Stainless Steel Building Products. It has also earned the company an excellent reputation for quality and reliability amongst the many architects, specifiers, engineers and building contractors that the business serves. Wincro is based in Sheffield, the home of stainless steel. We produce a wide range of corrosion resistant fixings, support systems, flooring and access equipment. Our range is constantly evolving and developing in order to keep pace with the demands of a fast-moving industry and the changing needs of our clients.

TECHNICAL DESIGN EXPERTISE


The quality of the Wincro product range is matched by the quality of the design assistance available to specifiers and contractors through our technical department. This can range from simple guidance to a full design service. So whether you need advice on selecting the appropriate standard Lintel or a custom-made solution for use in arches or bays, youll find our Technical Design Team is always happy to help. On site technical assistance is available if required. We also offer a take off/scheduling service for drawings and provide structural performance calculations.

CONTENTS
LINTELS GENERAL INFORMATION LINTEL PRODUCT SELECTOR 50-70MM CAVITY STANDARD LOADING LINTELS 50-70MM CAVITY HEAVY DUTY LOADING LINTELS 70-90MM CAVITY STANDARD LOADING LINTELS 70-90MM CAVITY HEAVY DUTY LOADING LINTELS 90-110MM CAVITY STANDARD LOADING LINTELS 90-110MM CAVITY HEAVY DUTY LOADING LINTELS 50-110MM CAVITY EXTRA HEAVY DUTY LINTELS SOLID WALL LINTELS BOX LINTELS STANDARD LOADING BOX LINTELS HEAVY DUTY LOADING SINGLE LEAF LINTELS EAVES LINTELS ARCH LINTELS 2-3 4-5 6 7 8 9 10 11 12 13 14 15 16-17 18 19-21

MAINTAINING HIGH STANDARDS


The highest standards are maintained both in terms of the materials from which our products are made and the techniques employed in manufacturing. Every single item in our Lintels range complies with the requirements of the BS EN 9001:1994 standard. In addition, we hold a number of accreditations such as NHBC and BSSA, so you can have total confidence in the products we supply. In addition NBS Plus contains references for Wincro Lintels that can be included directly into your specifications when using NBS Specification Manager/Writer. Our Technical Design Team will be pleased to advise on the most appropriate products.

LINTELS GENERAL INFORMATION

LINTELS GENERAL INFORMATION


SUPPORT FOR SPECIFIER
We provide the following assistance to Architects, Structural Engineers and Contractors: Individual design service on full range of Specials On-site technical assistance Specification service for Architects and Engineers Take off/scheduling service for drawings Structural performance calculations

QUALITY STAINLESS STEEL


Wincro Lintels are manufactured from either high quality stainless steel Grade 1.4301 (304) or, for use in harsh environments that are particularly prone to corrosion, Grade 1.4401 (316). Our Lintels are also manufactured in Z1 grade galvanised steel to BS2989: 1982 with a zinc coating type G600 (H3), giving a minimum zinc coating of 600g/m2 (including both sides). In accordance with BS5977: part 2, 1983 all cut edges are treated with a corrosion resistant paint.

POWDER COATED RANGE (WLPK)


All our standard galvanised steel cavity wall Lintels up to 3000mm long can be supplied with an extra layer of protection provided by an electrostatically applied coating of thermal setting polyester powder. Our products have a 600gm galvanised zinc coating more than double that of other powder coated lintels.

THERMAL EFFICIENCY
The Wincro Lintel core is entirely filled with CFC free insulation, which completely fills all voids in the Lintel, particularly at the apex. This ensures continuity with wall insulation and the reduction of cold bridge effect in this area. With a thermal conductivity of 0.033 W/mk, the Wincro Lintel range is one of the most thermally efficient on the market today.

STRUCTURAL PERFORMANCE
Safe working loads for Wincro Lintels are shown in each applicable loading table. These take into account the differential loading arrangements which are common to traditional cavity wall construction. Differential Load 3:1 ratio, 75% load on inner leaf Differential Load 19:1 ratio, 95% load on inner leaf Wincro Lintels coded WLPHK, WLSK50 (215WIL), WLSK70 (215WIL), WLSK90 (215WIL), WLSBK, WLTK, WLPTK, WLSLK, WLRBK, WLINTK, WLSWK, WLIBK, WLEPK50WIL, WLCFSK, WLXK have been tested as a composite unit with surrounding masonry, built in accordance with the requirements of BS5628. The composite units have been tested in accordance with the requirements of BS5977: Part 2 1983.
95 48 100

h-nominal

tel:+44 (0) 114 242 2171

fax:+44 (0) 114 243 4306

email:sales@wincro.com

www.wincro.com

LINTELS GENERAL INFORMATION

EXTENSIVELY TESTED
Our Lintel range has been subjected to a rigorous series of tests. The Lintel testing procedure and British Board of Agreement assessment is carried out under the direct supervision of the Department of Civil Engineering, University of Ulster. Fire Test: The WLSK and WLPK Lintel ranges have been subjected to fire tests at the Warrington Fire Research Station and have achieved a one-hour fire certificate by successfully supporting their imposed load for 48 hours after the tests. Durability: The service life of our Lintels is the same as that anticipated for the building in which they are used. This assumes the Lintels are used in conjunction with a flexible DPC, within a habitable building presenting normal levels of humidity and condensation. The range complies with the technical requirements of the Housing Association Property Manual (HAPM) with appropriate adjustment factors.

INSTALLATION
The lintels should be installed with a minimum end bearing of 150mm bedded in mortar, levelled along their length and across their width. With cavity walls, both leaves should be raised together to avoid excessive eccentricity of loading and be allowed to cure before applying floor or roof loads. Blockwork is permitted to overhang the Lintel flange by a maximum of 25mm. Point loads and concrete floor units should not be applied without prior consultation with our Technical Design Team or a Structural Engineer. Care should also be taken in the selection of Lintels for each application with regard to wall construction, cavity width and loads applied. A Cavity Tray should be installed over all openings in external cavity walls. We offer an extensive range of special Lintels, which can be custom-made to your own specification.

HEALTH & SAFETY


All components and materials in our products are considered as non-hazardous to health under normal conditions of use, as determined by COSHH Regulations 1994. Due to their weight, care should be taken when lifting and handling Lintels. A table of weights for individual Lintel types is available on request. Please contact our Technical Design Team for further information.
h-nominal

120

48

100

LINTEL PRODUCT SELECTOR

LINTEL PRODUCT SELECTOR

50-70mm Cavity Wall Lintels Standard Loading

1.0 1.1 1.2 1.3 2.0 2.1 2.2 2.3

WLPK50 / WLSK50 WLPK50WIL / WLSK50WIL WLSK50WOL WLSK50215WIL

1.0

1.1

1.2

1.3

Heavy Duty Loading


WLHDK50 WLHDK50WIL WLCFSK50 WLCFSK50WIL

For further information see pages 6-7

2.0

2.1

2.2

2.3

70-90mm Cavity Wall Lintels Standard Loading

3.0 3.1 3.2 3.3 4.0 4.1 4.2 4.3

WLPK70 / WLSK70 WLPK70WIL / WLSK70WIL WLSK70WOL WLSK70215WIL

3.0

3.1

3.2

3.3

Heavy Duty Loading


WLHDK70 WLHDK70WIL WLCFSK70 WLCFSK70WIL

For further information see pages 8-9

4.0

4.1

4.2

4.3

90-110mm Cavity Wall Lintels Standard Loading

5.0 5.1 5.2 5.3 6.0 6.1 6.2 6.3

WLPK90 / WLSK90 WLPK90WIL / WLSK90WIL WLSK90WOL WLSK90WIL

5.0

5.1

5.2

5.3

Heavy Duty Loading


WLHDK90 WLHDK90WIL WLCFSK90 WLCFSK90WIL

For further information see pages 10-11

6.0

6.1

6.2

6.3

Extra Heavy Duty Lintels

7.0 7.1 7.2 7.3

WLXK WLXKWIL WLXK215WIL WLIBXK

For further information see page 12

7.0

7.1

7.2

7.3

tel:+44 (0) 114 242 2171

fax:+44 (0) 114 243 4306

email:sales@wincro.com

www.wincro.com

LINTEL PRODUCT SELECTOR

Solid Wall Lintels Standard Loading

8.0

8.1

8.2

8.3

8.0 8.1 8.2 8.3

WLINTK WLSWK WLIBK (2c) WLIBK (3c)

For further information see page 13

Box Lintels Standard Loading

9.0

9.1

9.2

9.3

9.0 9.1 9.2 9.3

WLBOXK75 WLBOXK100 WLBOXK150 WLBOXK200

Heavy Duty Loading

10.0 10.1 10.2

WLHDBOXK100 WLHDBOXK150 WLHDBOXK200

For further information see pages 14-15

10.0

10.1

10.2
Single Leaf Lintels

11.0

11.1

11.2

11.0 11.1 11.2 11.3 11.4 11.5

WLSBK WLSLK WLSWK100 WLTK WLBK WLRBK

For further information see pages 16-17

11.3

11.4

11.5
Eaves Lintels
For further information see page 18

12.0

12.1

12.0 12.1

WLEPK50 WLEPK50WIL

Arch Lintels Venetian Lintels


r

(arch span) a2

13.0 13.1
c

To special order To special order

13.0

13.1

(overall clear span)

Gothic Arch Lintels


(Single Radius)

14.0 14.1
r

To special order To special order

For further information see pages 19-21

(clear span) a Elevation

14.0

14.1

50-70MM CAVITY STANDARD LOADING LINTELS

50-70MM CAVITY STANDARD LOADING LINTELS

1.0
Height h Thickness

WLPK50
600 1350 1650 1950 2250 2550 2850 1200 1500 1800 2100 2400 2700 3000 79 1.6 12 10 95 2 14 12 110 134 2 19 16 2 21 17 150 2 21 19 172 2 26 22 172 2.6 27 20

WLSK50
3150 3750 4200* 3600 4000 4800* 209 3.2 27 20 209 3.2 26 19 209 3.4 27 22
h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN

95

48

100

2.0
Height h Thickness

WLPK50WIL 150mm wide inner leaf


600 1500 1950 2250 2550 3000 172 2.6 28 21

WLSK50WIL
3150*3750*4200* 3600*4000* 196 3.2 30 26 196 3.2 27 25 196 3.4 26 22
h-nominal

Manufactured length in 150mm increments

1350 1650 1800 2100 2400 91 2 12 10 96 2 12 10 110 2 15 13 136 2 20 18 162 2 24 20

Total UDL 3:1 kN Total UDL 19:1 kN

95

48

125

3.0
Height h Thickness

WLSK50215WIL 215mm wide inner leaf


600* 1350* 1650* 1950* 2250* 2550* 2850* 3150* 1200* 1500* 1800* 2100* 2400* 2700* 3000* 4000* 78 2.6 25 20 100 104 2.6 25 20 120 121 2.6 25 20 140 146 2.6 30 25 175 171 2.6 30 25 225 171 2.9 35 30 225 209 2.9 40 35 225 209 3.2 40 35 225
h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN Fin Height

1.0 / 1.1
1 Extended fin 225mm high for lintels greater than 2100mm long 2 Fin height equals lintel height up to 2100mm long
95 48 210

For standard loading conditions with 215mm wide inner leaf as a composite beam. To achieve loading figures lintel must be built in with blockwork as shown

1.0

1.1

4.0
Height h Thickness

WLSK50WOL 150mm wide outer leaf


600 1350 93 2.6 14 11 1500 1650 110 2.6 15 13 1800 2100 162 2.6 23 18 2250 2700 200 2.9 30 22 2850* 3000* 200 3.2 32 30 3150* 3600* 200 3.2 30 26
h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN

120

48

100

tel:+44 (0) 114 242 2171

fax:+44 (0) 114 243 4306

email:sales@wincro.com

www.wincro.com

50-70MM CAVITY HEAVY DUTY LOADING LINTELS

50-70MM CAVITY HEAVY DUTY LOADING LINTELS

5.0
Height h Thickness

WLHDK50
600 1500 1800* 2100* 171 3.2 32 24 2250* 3000* 209 3.2 37 33 3150* 3600* 209 3.2 34 31 3750* 4000* 209 3.2 30 27 208 3.4 30 27
95 48 100 h-nominal

Manufactured length in 150mm increments

4200*

1350 1650* 105 3.2 21 18 121 3.2 27 22

Total UDL 3:1 kN Total UDL 19:1 kN

6.0
Height h Thickness

WLHDK50WIL 150mm wide inner leaf


600 1350 95 3.2 20 17 1500* 1650* 109 3.2 25 22 1800* 2100* 161 3.2 30 25 2250* 2700* 200 3.2 36 32
h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN

95

48

125

7.0
Height h Thickness Total UDL kN

WLCFSK50
600 1500 229 2.9 60 1650 2100 229 2.9 50 2250 3000 229 2.9 45 3150 4000 229 3.2 45 4200 4800 229 3.4
229

Manufactured length in 150mm increments

40

To achieve loading figures, lintel must be built in with blockwork as shown

95

48

100

8.0
Height h Thickness Total UDL kN

WLCFSK50WIL 150mm wide inner leaf


600 1500 229 2.9 60 1650 2100 229 2.9 50 2250 3000 229 2.9 45 3150 4000 229 3.2 45 4200 4800 229 3.4 40
229

Manufactured length in 150mm increments

To achieve loading figures, lintel must be built in with blockwork as shown


* Continuous Bottom Plate

95

48

125

70-90MM CAVITY STANDARD LOADING LINTELS

70-90MM CAVITY STANDARD LOADING LINTELS

1.0
Height h Thickness

WLPK70
600 1350 1650 1950 2250 2550 1200 1500 1800 2100 2400 3000 98 1.6 12 10 89 2 14 12 106 2 18 14 130 2 21 17 142 2 21 19 168 2.6 27 22

WLSK70
3150 3600 204 3.2 27 20 3750 4200* 4000 4800* 204 3.2 26 19 204 3.4 27 22
h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN

95

68

100

2.0
Height h Thickness

WLPK70WIL 150mm wide inner leaf


600 1500 1950 2250 2550

WLSK70WIL

Manufactured length in 150mm increments

3150* 3750* 4200* 3600* 4000* 192 3.2 30 26 192 3.2 27 25 192 3.4 26 22
95 68 125 h-nominal

1350 1650 1800 2100 2400 3000 93 2 12 10 90 2 13 11 110 2 20 17 134 2 19 17 158 2 24 20 167 2.6 27 21

Total UDL 3:1 kN Total UDL 19:1 kN

3.0
Height h Thickness

WLSK70215WIL 215mm wide inner leaf


600* 1350* 1650* 1950* 2250 2550* 2850* 3150* 2

Manufactured length in 150mm increments

1200* 1500* 1800* 2100* 2400* 2700* 3000* 4000* 67 2.6 25 20 100 100 2.6 25 20 120 110 2.6 25 20 140 142 2.6 30 25 175 167 2.6 30 25 225 167 2.9 35 30 225 204 2.9 40 35 225 204 3.2 40 35 225
h-nominal

Total UDL 3:1 kN Total UDL 19:1 kN Fin Height

1.0 / 1.1
1 Extended fin 225mm high for lintels greater than 2100mm long 2 Fin height equals lintel height up to 2100mm long

95

68

210

For standard loading conditions with 215mm wide inner leaf as a composite beam. To achieve loading figures lintel must be built in with blockwork as shown

1.0

1.1

4.0
Height h Thickness

WLSK70WOL 150mm wide outer leaf


600 1350 93 2.6 14 11 1500 1650 110 2.6 15 13 1800 2100 162 2.6 23 18 2250 2700 200 2.9 30 22 2850* 3000* 200 3.2 32 30 3150* 3600* 200 3.2 30
h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN

26
120 68 100

tel:+44 (0) 114 242 2171

fax:+44 (0) 114 243 4306

email:sales@wincro.com

www.wincro.com

70-90MM CAVITY HEAVY DUTY LOADING LINTELS

70-90MM CAVITY HEAVY DUTY LOADING LINTELS

5.0
Height h Thickness

WLHDK70
600 1350 103 3.2 21 18 1500 1650* 117 3.2 27 22 1800* 2100* 167 3.2 32 24 2250* 3000* 205 3.2 37 33 3150* 3600* 205 3.2 34 31 3750* 4000* 205 3.2 30 27 205 3.4 30 27
95 68 100 h-nominal

Manufactured length in 150mm increments

4200*

Total UDL 3:1 kN Total UDL 19:1 kN

6.0
Height h Thickness

WLHDK70WIL 150mm wide inner leaf


600 1350 101 3.2 20 17 1500* 1650* 117 3.2 25 22 1800* 2100* 169 3.2 30 25 2250* 2700* 207 3.2 36 32
95 68 125 h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN

7.0
Height h Thickness Total UDL kN

WLCFSK70
600 1500 229 2.9 60 1650 2100 229 2.9 50 2250 3000 229 2.9 45 3150 4000 229 3.2 45 4200 4800 229 3.4 40
229

Manufactured length in 150mm increments

95

68

100

To achieve loading figures, lintel must be built in with blockwork as shown

8.0
Height h Thickness Total UDL kN

WLCFSK70WIL 150mm wide inner leaf


600 1500 229 2.9 60 1650 2100 229 2.9 50 2250 3000 229 2.9 45 3150 4000 229 3.2 45 4200 4800 229 3.4 40
229

Manufactured length in 150mm increments

To achieve loading figures, lintel must be built in with blockwork as shown


* Continuous Bottom Plate

95

68

125

10

90-110MM CAVITY STANDARD LOADING LINTELS

90-110MM CAVITY STANDARD LOADING LINTELS

1.0
Height h Thickness

WLPK90

WLSK90

Manufactured length in 150mm increments

600 1350 1650 1950 2250 2550 2850 3150 3750 4200* 1200 1500 1800 2100 2400 2700 3000 3600 4000 4800* 88 1.6 12 10 85 2 16 13 107 2 19 16 125 2 21 17 150 2 23 18 162 2.6 27 22 171 2.6 27 20 200 3.2 27 20 200 3.2 26 19 200 3.4 27 22
95 88 100 h-nominal

Total UDL 3:1 kN Total UDL 19:1 kN

2.0
Height h Thickness

WLPK90WIL 150mm wide inner leaf


600 1200 82 2 13 11 1350 1800 107 2 17 14 1950 2400 142 2 23 18 2550 3000 177 2.6 24 18 3150* 3600* 188 3.2 30 26

WLSK90WIL
3750* 4200* 4000* 188 3.2 27 25 188 3.4 26 21
95 88 125 h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN

3.0
Height h Thickness

WLSK90215WIL 215mm wide inner leaf


600* 1350* 90 2.6 25 20 100 1500* 1650* 105 2.6 25 20 120 1800* 2100* 138 2.6 30 25 175 2250* 2400* 163 2.9 35 30 225 2550* 3000* 200 2.9 40 35 225 3150* 4000* 200 3.2 40 35 225 1
h-nominal

Manufactured Length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN Fin Height

1.0 / 1.1
1 Extended fin 225mm high for lintels greater than 2100mm long 2 Fin height equals lintel height up to 2100mm long

95

88

210

For standard loading conditions with 215mm wide inner leaf as a composite beam. To achieve loading figures lintel must be built in with blockwork as shown

3.0

3.1

4.0
Height h Thickness

WLSK90WOL 150mm wide outer leaf


600 1350 93 2.6 14 11 1500 1650 110 2.6 15 13 1800 2100 162 2.6 23 18 2250 2700 200 2.9 30 22 2850* 3000* 200 3.2 32 30 3150* 3600* 200 3.2 30
h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN

26
120 88 100

tel:+44 (0) 114 242 2171

fax:+44 (0) 114 243 4306

email:sales@wincro.com

www.wincro.com

90-110MM CAVITY HEAVY DUTY LOADING LINTELS

11

90-110MM CAVITY HEAVY DUTY LOADING LINTELS

5.0
Height h Thickness

WLHDK90
600 1350 110 3.2 21 18 1500 1650* 135 3.2 27 22 1800* 2100* 163 3.2 32 24 2250* 3000* 203 3.2 37 33 3150* 3600* 203 3.2 34 31 3750* 4000* 203 3.2 30 27 203 3.4 30 27
95 88 100 h-nominal

Manufactured length in 150mm increments

4200*

Total UDL 3:1 kN Total UDL 19:1 kN

6.0
Height h Thickness

WLHDK90WIL 150mm wide inner leaf


600 1350 113 3.2 20 17 1500* 1650* 135 3.2 25 22 1800* 2100* 165 3.2 30 25 2250* 2700* 203 3.2 36 32
95 88 125 h-nominal

Manufactured length in 150mm increments

Total UDL 3:1 kN Total UDL 19:1 kN

7.0
Height h Thickness Total UDL kN

WLCFSK90
600 1500 229 2.9 60 1650 2100 229 2.9 50 2250 3000 229 2.9 45 3150 4000 229 3.2 45 4200 4800 229 3.4 40
229

Manufactured length in 150mm increments

95

88

100

To achieve loading figures, lintel must be built in with blockwork as shown

8.0
Height h Thickness Total UDL kN

WLCFSK90WIL 150mm wide inner leaf


600 1500 229 2.9 60 1650 2100 229 2.9 50 2250 3000 229 2.9 45 3150 4000 229 3.2 45 4200 4800 229 3.4 40
229

Manufactured length in 150mm increments

To achieve loading figures, lintel must be built in with blockwork as shown


* Continuous Bottom Plate

95

88

125

12

50-110MM CAVITY EXTRA HEAVY DUTY LINTELS

50-110MM CAVITY EXTRA HEAVY DUTY LINTELS

1.0
End bearing Total UDL kN

WLXK50 / WLXK70 / WLXK90

Manufactured length to customers requirements 4800 200 86

5200 200 75

5400 200 70

5800 200 65

6200 200 60

6600 200 55
229

1.0 / 1.1
1 Stainless steel or galvanised mild steel flange to outer leaf 2 230 x 90 x 32.76kg/m RS Channel 2 1

To achieve loading figures, lintel must be laterally restrained. Lintel must be built in with block/brickwork as shown and suitably propped during construction. WLXK lintel range is available to suit 50-110mm cavity width. eg Specify WLXK70, WLXK90

95

48

100

1.0

1.1

2.0
End bearing Total UDL kN

WLXK50WIL / WLXK70WIL / WLXK90WIL 150mm wide inner leaf

Manufactured length to customers requirements 4800 200 86

5200 200 75

5400 200 70

5800 200 65

6200 200 60

6600 200 55
229

2.0 / 2.1
Stainless steel or galvanised mild steel flange to outer leaf 230 x 90 x 32.76kg/m RS Channel To achieve loading figures, lintel must be laterally restrained. Lintel must be built in with block/brickwork as shown and suitably propped during construction. WLXK lintel range is available to suit 50-110mm cavity width. e.g. Specify WLXK70, WLXK90
1 2 2 1

95

48

125

2.0

2.1

3.0
End bearing Total UDL kN

WLXK50215WIL / WLXK70215WIL / WLXK90215WIL 215mm wide inner leaf

Manufactured length to customers requirements 4800 200 86

5200 200 75

5400 200 70

5800 200 65

6200 200 60

6600 200 55

3.0 / 3.1
Stainless steel or galvanised mild steel flange to outer leaf 230 x 90 x 32.76kg/m RS Channel To achieve loading figures, lintel must be laterally restrained. Lintel must be built in with block/brickwork as shown and suitably propped during construction. WLXK215WIL lintel range is available to suit 50-110mm cavity width. eg Specify WLXK70215WIL, WLXK90215WIL
1 2 2 1
95 48 215

3.0

3.1

4.0
End bearing Total UDL kN

WLIBXK 215mm wide solid wall

Manufactured length to customers requirements 4800 200 86

5200 200 75

5400 200 70

5800 200 65

6200 200 60

6600 200 55

4.0 / 4.1
1 2

Stainless steel or galvanised mild steel flange to outer leaf 230 x 90 x 32.76kg/m RS Channel

2 1

To achieve loading figures, lintels must be laterally restrained. Lintel must be built in with block/brickwork as shown and suitably propped during construction

4.0

4.1

tel:+44 (0) 114 242 2171

fax:+44 (0) 114 243 4306

email:sales@wincro.com

www.wincro.com

SOLID WALL LINTELS

13

SOLID WALL LINTELS

1.0
Max Span

WLINTK
900 700 5 10 1050 850 5 10 1100 900 5 10 1200 1000 5 10

Overall length

100

Total UDL kN with 150mm coursing Total UDL kN with 225mm coursing

28

For standard loading conditions to support internal openings in 100mm and 75mm wide walls, eg Specify WLINTK75

2.0
Height h Thickness Total UDL kN

WLSWK
600 1200 55 2.6 6 1350 1650 86 2.6 8 1800 2100 86 2.9 8 2250 2700 113 3.2 10
h-nominal

Manufactured length in 150mm increments

For light duty loading conditions for 215mm solid wall construction. To achieve loading figures, lintel must be built in with block/brickwork as shown and suitably propped during construction

195

3.0
Height h Thickness Total UDL kN

WLIBK (2c)
600 1800 152 2.6 30 1950 2400 152 2.9 30 2250 3000 152 3.2 30
152

Manufactured length in 150mm increments

For heavy duty loading conditions for 215mm solid wall construction. To achieve loading figures, lintel must be built in with block/brickwork as above as shown and suitably propped during construction.

195

4.0
Height h Thickness Total UDL kN

WLIBK (3c)
600 1800 227 2.6 40 1950 2100 227 2.6 40 2250 3000 227 2.9 40 3150 4000 227 3.2 40 4200 4800 227 3.4 35
227

Manufactured length in 150mm increments

For heavy duty loading conditions for 215mm solid wall construction. To achieve loading figures, lintel must be built in with block/brickwork as above work as shown and suitably propped during construction

195

14

BOX LINTELS STANDARD LOADING

BOX LINTELS STANDARD LOADING

1.0
Height h Thickness Total UDL kN

WLBOXK60 / WLBOXK75
WLBOXK60 WLBOXK75

Used to support interal openings

Manufactured length in 150mm increments

600 1500 95 1.6 15

1650 1300 95 1.6 10

600 1650 75 1.6 15 1800


75

75
95

2.0 10
75 95

1.0 / 1.1
1 Box 75 2 Box 60 3 Perforated steel for plaster key 1 3 1 2

Used to support internal openings in 75mm wide walls (WLBOXK60) and 100mm wide walls (WLBOXK75)

1.0

1.1

2.0
Height h Thickness Total UDL kN

WLBOXK100
600 1800 150 1.6 18 1650 1800 150 1.6 18 1950 2400 150 2.0 25 2550 2700 150 2.0 20 2850 3600 215 2.6 35 3750 4000 215 2.6 30 4200 4800 215 2.6 24
75 95 h-nominal

Manufactured length in 150mm increments

2.0 / 2.1
1 Perforated steel for plaster key 1

95

Used to support internal or external openings with 100mm wide wall

2.0

2.1

3.0
Height h Thickness Total UDL kN

WLBOXK150
600 1800 150 1.6 18 1950 2400 150 2.0 25 2550 2700 150 2.0 20 2850 3600 215 2.6 35 3750 4000 215 2.6 30 4200 4800 215 2.6 24
h-nominal

Manufactured length in 150mm increments

3.0 / 3.1
1 Perforated steel for plaster key 1
145

Used to support internal or external openings with 150mm wide wall

3.0

3.1

4.0
Height h Thickness Total UDL kN

WLBOXK200
600 1800 150 1.6 18 1950 2400 150 2.0 25 2550 2700 150 2.0 20 2850 3600 215 2.6 35 3750 4000 215 2.6 30 4200 4800 215 2.6 24
h-nominal

Manufactured length in 150mm increments

4.0 / 4.1
1 Perforated steel for plaster key

200

Used to support internal or external openings with 215mm wide wall

4.0

4.1

tel:+44 (0) 114 242 2171

fax:+44 (0) 114 243 4306

email:sales@wincro.com

www.wincro.com

BOX LINTELS HEAVY DUTY LOADING

15

BOX LINTELS HEAVY DUTY LOADING

5.0
Height h Thickness Total UDL kN

WLHDBOXK100
600 1200 150 2.6 47 1350 1800 150 2.6 44 1950 2700 215 2.6 38
h-nominal

Manufactured length in 150mm increments

5.0 / 5.1
1 Perforated steel for plaster key

For heavy duty loading conditions to support internal or external opening with 100mm wide wall

95

5.0

5.1

6.0
Height h Thickness Total UDL kN

WLHDBOXK150
600 1200 150 2.6 47 1350 1800 150 2.6 44 1950 2700 215 2.6 38
h-nominal

Manufactured length in 150mm increments

6.0 / 6.1
1 Perforated steel for plaster key

For heavy duty loading conditions to support internal or external openings with 150mm wide wall

145

6.0

6.1

7.0
Height h Thickness Total UDL kN

WLHDBOXK200
600 1200 150 2.6 47 1350 1800 150 2.6 44 1950 2700 215 2.6 38
h-nominal

Manufactured length in 150mm increments

7.0 / 7.1
1 Perforated steel for plaster key

1
200

For heavy duty loading conditions to support internal or external openings with 215mm wide wall

7.0

7.1

16

SINGLE LEAF LINTELS

SINGLE LEAF LINTELS

1.0
Height h Thickness Total UDL kN

WLSBK
600 1350 80 3.2 2.5 1500 1800 100 3.2 5 1950 2250 150 3.2 7 2400 2700 200 3.2 8

Manufactured length in 150mm increments

1.0 / 1.1
1 Optional factory fitted Cavity Closer (Specify WLSBK/cc)
h-nominal

For use to support the outer leaf of cavity wall construction. The WLSBK lintel should be suitably propped during construction. The WLSBK lintel can be supplied with no top bend (e.g. specify WLANGK)

1
95

1.0

1.1

2.0
Height h Thickness Total UDL kN

WLSLK
600 1350 80 2.6 5 1500 1800 150 2.6 10 1950 2400 227 2.6 12 2550 2700 227 2.9 12 2850 3000 227 3.2 12
h-nominal

Manufactured length in 150mm increments

For use to support single leaf or outer leaf of cavity wall construction. To achieve loading figures, lintel must be built in with brickwork as shown and be suitably propped during construction

95

3.0
Height h Thickness Total UDL kN

WLSWK100
600 1200 55 2.6 6 1350 1650 86 2.6 8 1800 2100 86 2.9 8 2250 2700 113 3.2 10

Manufactured length in 150mm increments

h-nominal

Suitable for 100mm and 150mm wide wide solid walls. To achieve loading figures, lintel must be built in with brickwork as shown and be suitably propped during construction

95

tel:+44 (0) 114 242 2171

fax:+44 (0) 114 243 4306

email:sales@wincro.com

www.wincro.com

SINGLE LEAF LINTELS

17

4.0
Height h Thickness Total UDL kN

WLTK50 / WLTK70 / WLTK90


600 1650 102 2.6 5 1800 2400 155 2.6 8 2550 3000 185 2.9 9 3150 4000 250 3.2 12 4200 4800 250 3.4 12
h-nominal

Manufactured length in 150mm increments

4.0 / 4.1
1 Clips 2 Batten

For use with timber frame construction. The WLTK lintel must be used in conjunction with lateral restraint clips and a tight fitting timber batten, as shown, to prevent twisting. The WLTK range can be supplied to suit wider cavities: e.g. specify WLTK70, WLTK90 Lateral Restraint Clips at 500mm centres fixed with 4mm x 50mm stainless steel or galvanised mild steel nails

95

50

4.0

4.1

5.0
Height h Thickness Total UDL kN

WLBK50 / WLBK70 / WLBK90


600 2100 150 2.6 7 2250 2400 225 2.6 8 2550 3000 225 2.9 10 3150 4000 225 3.2 12 4200 4800 225 3.4 12

Manufactured length in 150mm increments

5.0 / 5.1
1 Batten

h-nominal

For use with inner leaf concrete lintel. The WLBK lintel must be used in conjunction with a tight fitting timber batten, as shown, to prevent twisting. The WLBK range can be supplied to suit wider cavities: e.g. specify WLBK70, WLBK90

95

50

5.0

5.1

6.0
Height h Thickness Total UDL kN

WLRBK50 / WLRBK70 / WLRBK90


600 1500 250 2.6 7.5 1650 2400 250 2.9 7.5 2550 3000 250 2.9 7.5 3150 4000 250 3.2 7.5 4200 1 4800 250 3.4 7.5

Manufactured length in 150mm increments

6.0 / 6.1
1 Expansion Bolts

For use with internal concrete ring beams. The WLRBK type lintel must be bolted to the concrete ring beam at 400mm centres using WBEB M16 expansion bolts. The WLRBK type range can be supplied to facilitate various cavity widths: e.g. specify WLRBK50, WLRBK70, WLRBK90

95 nominal

6.0

6.1

18

EAVES LINTELS

EAVES LINTELS

1.0
Height h Thickness Total UDL kN

WLEPK50
600 1500 95 2 18 1650 2100 134 2 20 2250 2400 150 2 22 2550 2700 150 2.6 25

Manufactured length in 150mm increments

40

48

100

For standard loading conditions at eaves level as a composite beam. To achieve loading figures lintel must be built with blockwork and wall plates as shown

2.0
Height h Thickness Total UDL kN

WLEPK50WIL 150mm wide inner leaf


600 1500 91 2 18 1650 2100 136 2 20 2250 2400 136 2.6 25 2550 2700 150 2.6 20

Manufactured length in 150mm increments

40

48

125

For standard loading conditions at eaves level as a composite beam. To achieve loading figures lintel must be built in with blockwork and wall plates as shown

3.0

SOFFIT LINTELS

A soffit plate can be supplied on all lintel profiles to suit 50-110mm wide cavities, suffix all product codes SF (eg. specify WLSK90WIL/SF)

4.0

STEPPED LINTELS

All cavity lintels in the Wincro range can be supplied with a 20mm step on request, suffix all product codes ST (eg. specify WLSK90/ST)

tel:+44 (0) 114 242 2171

fax:+44 (0) 114 243 4306

email:sales@wincro.com

www.wincro.com

ARCH LINTELS

19

ARCH LINTELS

1.0

VENETIAN LINTEL

LINTEL DIMENSION

ARCH TYPE

Overall clear span a1 = Arch span a2 = Rise r = End bearing c =

mm mm mm mm

(please tick)

Full arch Segmented arch Parabolic arch Apex arch Gothic arch

WALL CONSTRUCTION SUPPORT POSTS


Outer leaf Cavity width Inner leaf mm mm mm
(If required)

Height

mm

PLASTER KEY REQUIREMENTS


(please tick)
elevation r

Inside only Both sides None


c (arch span) a2 c

(overall clear span) a1

2.0

GOTHIC ARCH LINTEL (SINGLE RADIUS)

LINTEL DIMENSION

Clear span a= Radius r= End bearing c=

mm mm mm

WALL CONSTRUCTION

Outer leaf Cavity width Inner leaf

mm mm mm

PLASTER KEY REQUIREMENTS


(please tick)

Inside only Both sides None


elevation r r

Also available, Gothic Arch with Double Radius, please contact our Technical Design Team for further information.

(clear span) a elevation

20

ARCH LINTELS

ARCH LINTELS (CONTINUED)

3.0

FULL ARCH LINTEL *

(clear span) a elevation

4.0

SEGMENTAL ARCH LINTEL*

(clear span) a elevation

5.0

APEX ARCH LINTEL *

(clear span) a elevation

When requesting information on the above Lintels, please take into consideration the following information: * Using tables 6.0, 7.0, 8.0 on page 20. For further information contact our Technical Design Team ** Using tables 7.0, 8.0, 9.0 on page 20. For further information contact our Technical Design Team

6.0
Radius r =

LINTEL DIMENSION
mm mm mm

7.0
Outer leaf Inner leaf

WALL CONSTRUCTION
mm mm mm

8.0
(please tick)

PLASTER KEY REQUIREMENTS

9.0
Height

SUPPORT POSTS
mm

Clear span a =

Cavity width

Inside only Both sides None

End bearing c=

tel:+44 0114 242 2171

fax:+44 0114 243 4306

email:sales@wincro.com

www.wincro.com

ARCH LINTELS

21

10.0
A

CORNER LINTEL**

11.0
Brick reveal mm mm mm A

SQUARE BAY LINTEL **

Brick reveal Dimensions required: A-B= B-C= A-C=

Dimensions required: A-B= B-C= C-D= mm mm mm

Brick reveal D

Brick reveal

B C

12.0

PARABOLIC ARCH LINTEL *

(clear span) a elevation

13.0

CONSTRUCTING A PARABOLIC CURVE

Draw rectangle ABCD Make DE = DA Make CF = CE Bisect AF to make point 1 Project a right angle off AF at point 1 to find a smaller radius r, and project further to find large radius R

Designed by The Bright Partnership Ltd. 0114 296 2500

Wincro Metal Industries Ltd.


Wincobank Works > Fife Street > Sheffield > S9 1NJ > UK
tel:

+44 0114 242 2171

fax:

+44 0114 243 4306

email:

sales@wincro.com

www.wincro.com
Wincro Metal Industries Ltd.
Wincobank Works > Fife Street > Sheffield > S9 1NJ > UK
tel:

+44 (0) 114 242 2171

fax:

+44 (0) 114 243 4306

email:

sales@wincro.com

www.wincro.com

Trademarks: is the registered Trade Mark of Wincro Metal Industries Limited. Copyright: This publication and all its contents are the Copyright Wincro Metal Industries Limited 2004. No part of this publication may be reproduced in any form without the prior consent in writing of Wincro Metal Industries Limited. Trade Description Act: Wincro Metal Industries Limited is continually developing and improving its products and the descriptions contained in this publication are for general guidance only, they do not form part of any contract. To the best of our knowledge, the information contained in this document is accurate. Wincro Metal Industries Limited accepts no responsibility for errors in, or misinterpretation of the information in this document, or in its use.

BSSA

You might also like