Professional Documents
Culture Documents
5840 Osuna Rd. NE - Albuquerque, NM - (505) 889-7752 - Fax (505) 889-0258 - www.hydrotestlab.com
Method
ASTM D 4221 ASTM D 4943 ASTM D 854 / AASHTO T100 ASTM D 4647
* Classification(ASTM) for engineering purposes generally requires wet or dry sieves, hydrometer analysis and atterberg limits tests. **Other particle size analyses / sieve stacks / classifications available
Rev. 4 (1/16/07)
5840 Osuna Rd. NE - Albuquerque, NM - (505) 889-7752 - Fax (505) 889-0258 - www.hydrotestlab.com
Method
Flexible Wall
Constant head Falling head, rising tail ASTM D 5084 ASTM D 5084
Unsaturated Hydraulic Conductivity Hanging column method Pressure plate method Water potential method Relative humidity box See Note Below Calculated from moisture retention data Pressure membrane Air Permeability Air permeability Air permeability with Klinkenberg constant Soil-Water Characteristic Indices* Permanent Wilting Point (15 Bar Point) Effective Porosity (Total porosity - 15 Bar Point) Water Holding Capacity (15 Bar Point - 1/3 Bar Point) Plant Available Water (15 Bar Point - 1/3 Bar Point) Field Capacity (Total porosity - 1/3 Bar Point) Specific Yield (Total Porosity - Residual Moisture)
various various various various various various ASTM D4525 API RP 405/ MOSA1 Chp. 48 ASTM D 6836 / MOSA1 Chp. 26 ASTM D 6836 / ASTM D 2325 ASTM D 6836 / MOSA1 Chp. 3 SSSAJ, 19823 SSSAJ, 19804 ASTM D 3152
*Soil-Water Characteristic Indices analysis include moisture content, bulk density, total calculated porosity, and sample prep. Discount may apply for core samples. Any of the Soil-Water Characteristic Indices may be added to the Hydraulic Properties Package for $40.00.
Note: Requires determination of saturated hydraulic conductivity and moisture retention characteristics.
Rev. 4 (1/16/07)
5840 Osuna Rd. NE - Albuquerque, NM - (505) 889-7752 - Fax (505) 889-0258 - www.hydrotestlab.com
Method
Prep charges may apply at hourly rate Add any of the soil-water characteristic indices UST Site Testing (NM and TX - Can be modified to meet other state requirements) USTR Section 1209.B.e:
Soil bulk density Soil moisture content Effective porosity Total organic carbon See individual tests on schedule for methods.
ASTM / USDA Classification Package Standard (wet) particle size analysis. w/ hydrometer Atterberg Limits Classification for engineering purposes Proctor / Density Package Proctor Compaction
*Standard Proctor **Modified Proctor See individual tests on schedule for methods. See individual tests on schedule for methods.
Rev. 4 (1/16/07)
5840 Osuna Rd. NE - Albuquerque, NM - (505) 889-7752 - Fax (505) 889-0258 - www.hydrotestlab.com
Method
SSSAJ, 19846 SSSAP, 19627, SSSAJ, 19858 MOSA1, Chp. 39 MOSA1, Chp. 39 ASTM D 1331 ASTM D 971
Calibrations
Heat dissipation sensor Soil psychrometer Gypsum block TDR Neutron probe
Other Charges
Sample preparation / Technician time Fast-track surcharge Additional copies of reports (< 1 year) Additional copies of reports (> 1 year) Hazardous material surcharge (Depending on number of samples and level of contamination) Radioactive material surcharge (Depending on number of samples and level of contamination)
1 2 3 4 5 6 7 8
Methods of Soil Analysis, Part 1. 1986. A. Klute, ed. American Society of Agronomy, Madison, WI Page, A. L. 1982 Chp. 19-3, pp. 570-571, in A. L. Page (ed), Methods of Soil Analysis, American Society of Agronomy, Madison, WI Soil Sci. Soc. Am. J. 1980 44:892-898 Soil Sci. Soc. Am. J. 1984 48:7-10 Soil Sci. Soc. Am. P. 1962 26:421-426 Soil Sci. Soc. Am. J. 1985 49:1348-1354
Karathanasis & Hajek. 1982. Quantitative Evaluation of Water Adsorption on Soil Clays. SSA Journal 46:1321-1325 American Petroleum Institute Recommended Practices
Rev. 4 (1/16/07)
5840 Osuna Rd. NE - Albuquerque, NM - (505) 889-7752 - Fax (505) 889-0258 - www.hydrotestlab.com