You are on page 1of 2

POWERTRON

ADOR CORONA TR SETS & CONTROLS FOR ELECTROSTATIC PRECIPITATORS

Adors spread of competence in the world market extends to


Argentina Bulgaria Ethiopia Kenya New Zealand Romania Sweden Ukraine Australia Chile Finland Korea Nigeria Russia Tanzania Uruguay Austria China Indonesia Kuwait Oman Saudi Arabia Thailand USA Bahrain Colombia Ireland Lithuania Peru Siberia Turkey Bangladesh Cuba Japan Malaysia Philippines Singapore Uganda

52 Countries
Bhutan Denmark Jordan Myanmar Poland South Africa Venezuela Brazil Egypt Kazakhstan Nepal Portugal Spain UK

INDIAN CLIENT
Thermax Limited. Bharat Heavy Electricals Limited. Associated Cement Companies Ltd. Cethar Vessels Limited. Elex India Pvt. Ltd. FLSmidth Private Limited, Chennai. V T Corporartion. Himachal Environmental Engg. Co. Pvt. Enmass Engineering Pvt Ltd Sitson India Pvt. Ltd. Unicon Engineers. Hamon Shriram Cottrell Pvt. Ltd. Lodge Cottrell India Pvt. Ltd. Larsen & Toubro. Siemens India. Lurgi India Co Ltd. Andrew Yule & Co Ltd. Kirloskar AAF Limited. Orient Engineers

INTERNATIONAL CLIENT
Alstom Power Worldwide. FLSmidth Airtech,Denmark. Enfil S/A- Controle Ambiental, Brazil . Schneider Electric., France GE Energy., Worldwide ECP Finland. , Lodge Cottrell, UK. Environmental Elements Corporation,

Powering Precipitators Worldwide

ADOR POWERTRON LTD.

POWERTRON

Ramnagar Complex, MIDC Chinchwad, Pune - 411 019, INDIA Tel: 91-20-27473778, 27472532, 27471682 E-mail: cmo@adorpower.com

APL/TR/CAT/APR 10

Ltd. Soil & Enviro Industries Pvt. Ltd. Enviro Care Filtration & Systems. Batliboi Environmental Engineering Limited. Cheema Boilers Limited. Rieco Industries Limited.

USA. Interrollers, Singapore. Clean Airtech, Korea.

TR

11e,ts00ta0ed s ll S In

Over

CSA C-US
ONE OF THE LARGEST MANUFACTURING FACILITIES OF TR SETS IN THE WORLD

ONE OF THE LARGEST MANUFACTURING FACILITIES OF TR SETS IN THE WORLD

SALIENT FEATURES OF ADOR CORONA TR SETS


l Hermetically sealed construction. l HV transformer, rectifier, AC reactor & choke Assembly is lid mounted for convenience and ease of maintenance and repairs. l Conforms to Ingress Protection class IP-65 as per IEC PUB 947-1. l Doubly Wound, cross over winding with electrostatic shield between primary and secondary. l High Frequency Choke for surge protection of rectifier stack diodes. l High Voltage resistors for better stability and shield for induction free signal waveform. l HV Rectifier Stack design consists of special glass sealed passivated avalanche diodes, with controlled avalanche characteristics, which conduct the currents associated with transient waves in their reverse biased direction without being destroyed in the way that normal diodes are, thus ensuring highest possible immunity to traveling waves. l Standard Protections Include: Current Limiting Reactor, High Frequency Choke, Dial Thermometer, Pressure Release Valves, Pressure Switch, Oil Level Gauge.

ADOR CORONA TR SETS BRIEF SPECIFICATION OF TR SETS


Input Voltage Variation Frequency Output Voltage Output Current Design Form Factor Design Ambient Temp Humidity Various Configurations of Possible Ambient Bushing Orientation Method of Cooling: - Control Panel - T/R Set Natural/ Forced air cooled Oil Natural Air Natural Coolant: Mineral Oil/ Silicon Oil 415 Volts (PHASE - PHASE) 380V, 400V, 440V, 460V, 500V, 575V, 660V & 690V +/- 10% 50Hz / 60 Hz +/- 5% 30KV (P) to 200KV (P) On No Load at nominal rated I/P voltage 50mA to 3000mA Avg (mean) DC 1.2/ 1.3/ 1.4 MAX -30oC to 40oC 100%
o

Both Not Occurring Simultaneously

40/45/50/55 C with top oil temperature rise limited to 55/50/45/40oC Horizontal/ Vertical

ESP CONTROLS: SALIENT FEATURES OF ADOR CORONA CONTROL CABINET WITH PRECICON - III THIRD GENERATION MICROCONTROLLER FOR ELECTROSTATIC PRECIPITATOR APPLICATIONS. ADORs VERSATILE TR TANK CONSTRUCTION
l Sealed Corrugated Fin Tank (Hermetically Sealed Type). l Hermetically Sealed Tank with Nitrogen Blanket. l Tank with Radiator and Expansion conservator. l Improved collection efficiency. l Energy saving feature based on VI characteristic. l Additional optimisation modes: a) Charge ratio. b) Back corona. l Load status mode: Enabling selection between different operating parameter values for varying plant conditions. l Serial interface for communication Rs 485 modbus protocol. l Inbuilt rapping motor control feature for upto three independent rapper motors. l Computer aided ESP control management system: Precicom II.

CONTROL CABINET
l Fully customised control cabinets. l Interfacing option with all available ESP controller makes.

ALL TYPES OF MANUAL/MOTORISED/SOLENOID OPERATED H.T CHANGEOVER/GROUNDING SWITCHES/BUS COUPLERS


l Solenoid Operated Fail Safe H.T Grounding Switch. l H.T Grounding Switch (Oil/Air). l H.T Isolating Cum Grounding Switch. l Bus-Couplers

l Options for stand alone panels as well as cascaded arrangement.

ONE OF THE LARGEST MANUFACTURING FACILITIES OF TR SETS IN THE WORLD

ONE OF THE LARGEST MANUFACTURING FACILITIES OF TR SETS IN THE WORLD

You might also like