Professional Documents
Culture Documents
Features
Work mode
Master mode Slave mode
Transmission distance
Dual-strand fiber: up to 100km Single-strand fiber: up to 60km
Traffic monitoring
Collect the statistics of TX and RX traffic and display the statistics on the GUI of NView NNM system for flexiblly service monitoring
Typical Application
Interface
Indicator
Link indicator for optical interface TX/RX
Indicator
Description
ON: the TX/RX link of the optical interface is working properly OFF: TX/RX link fault
LNK
ACT
Flickering: data transmitting or receiving at the optical interface OFF: NO data transmitting or receiving at the optical interface
RMD
ON: there is remote device be detected OFF: there is no remote device be detected
LNK
ON: the TX/RX link of the optical interface is working properly OFF: TX/RX link fault
ACT
Flickering: data transmitting or receiving at the optical interface OFF: NO data transmitting or receiving at the optical interface
Power supply
PWR
ON: the power supply is working properly OFF: the power supply is NOT working in order
RC602-GEF (B) series optical fiber transceiver have one 8-bit DIP switch. Each bit of SW2 in turn are used to configure the following functions: disable/enable the ALS both on transmitting and receiving enable/disable remote management master device/slave device, disable/enable fault pass through
SW2-7
Fault pass-through from the line side optical interface to the client side optical interface
SW2-8
Fault pass through from the client side optical interface to the line side optical interface
NMS Function The status information of central site RC602GEF(B)-Master can be viewed via network management system NView. RC602-GEF(B)-Master can also be controlled and configured via NView NNM system. Furthermore, users can view the status information, control and configure remote RC602-GEF (B)-Slave through the central site RC602-GEF (B)-Master.
Configurable Parameter
Value
Remote management
Enable/Disable
Configurable
Enable/Disable
Configurable
Enable/Disable
Configurable
Open/Close
Configurable
Enable/Disable
Configurable
Open/Close
Configurable
Enable/Disable
Configurable
View Only
Status, Control and Configuration Item Card type Client optical module type Client optical interface: Link status Client optical interface (FP): control Client optical interface (FR): control Client optical interface : SD status Line optical module type Line optical interface: Link status Line optical interface (FP): control Line optical interface (FR): control Line optical interface: SD status Flow statistic: clent side receiving byte counts Flow statistic: client side transmitting byte counts Value RC602-GEF-REV_B-Master SFP only Up/Down Open/Close Open/Close Normal/Abnormal SFP only Up/Down Open/Close Open/Close Normal/Abnormal Flow statistic chart Flow statistic chart Including speed, transmission distance, working wavelength, module vendor, products type, version number and Production serial number Temperature,voltage, Bias current, Tx optical power, Rx optical power, and relevant alarm Including speed, transmission distance, working wavelength, module vendor, products type, version number and Production serial number Temperature,voltage, Bias current, Tx optical power, Rx optical power, and relevant alarm Features Unconfigurable Unconfigurable Unconfigurable Unconfigurable Unconfigurable Unconfigurable Unconfigurable Unconfigurable Unconfigurable Unconfigurable Unconfigurable Unconfigurable Unconfigurable
SFP vendor information of Client optical interface SFP digital diagnostic information of Client optical interface
Unconfigurable Unconfigurable
SFP vendor information of Line optical interface SFP digital diagnostic information of Lient optical interface
Unconfigurable Unconfigurable