You are on page 1of 109

AXONE 2000 Motor Truck

Dear repairer, Thank you for choosing our equipment for your workshop. We feel confident that you will be satisfied of it and that it will be of considerable help. Please read the instructions in this operation manual with great care and keep it close at hand for consultation. AXONE 2000 Motor Truck is a portable and self-powered engine diagnostic computer. It is highly effective and compact; it can be used for testing both on the road and in the workshop. The instrument can be updated with any diagnostic function required for modern car-repair by adding a special memory card containing the function. AXONE 2000 Motor Truck is ready for connection with the diagnostic units PEGASO EXPANDER of the Pegaso series, with a PC keyboard, a printer and a modem for communication with remote terminals.

AXONE 2000 Motor Truck

Data, technical specifications and descriptions contained in this manual are supplied as information only and are not binding for the manufacturer. The manufacturer can make any change deemed suitable for improving the product or for manufacturing or commercial reason. No part of this publication may be reproduced without the prior written permission of the manufacturer.
Feb 2004 Rev. A0 DTP and Communication Department

AXONE 2000 Motor Truck

CONTENTS
GENERAL SAFETY PRECAUTIONS HOW TO USE AXONE 2000 Motor Truck CORRECTLY ENVIRONMENTAL INFORMATION DESCRIPTION OF AXONE 2000 Motor Truck The Keyboard Interface Module Card reading and writing unit Input-output connectors AXONE 2000 Motor Truck power supply Battery charge Battery change NOTES FOR A CORRECT USAGE Automatic reset internal fuses TECHNICAL SPECIFICATIONS SPARE PARTS GLOSSARY GETTING STARTED How to enable a program HOW TO USE AXONE 2000 Motor Truck Service programs UP-GRADES Internet Connection Online Internet Updating MEASURES MULTIMETER VOLTMETER AMMETER OHMMETER Continuity Test OSCILLOSCOPE OPTIONS 1 2 4 5 5 7 8 9 10 11 11 12 13 14 16 17 17 23 24 26 33 33 34 35 37 38 39 41

II

AXONE 2000 Motor Truck

Input Cursors Zoom Grid Screen reset On-line help (0) SCALE SELECTIONS Scale selection (V) Scale selection (T) AC/DC READING SELECTION Ac reading selection Dc reading selection TYPES OF SYNCHRONISM Internal synchronism Manual synchronism External synchronism

42 43 45 46 46 47 48 49 50 52 53 53 54 55 56 57

FAST AUTO-DIAGNOSIS 59 Hot to connect AXONE 2000 Motor Truck to the Electronic Central Unit 63 How to supply power to the Auto-diagnosis interface cable 64 Connecting the Auto-Diagnosis socket 66 How to carry out a test 67 How to select make and model 68 Start of diagnosis 72 Engineering parameters 74 Current and saved errors 75 STO function 77 Inputs status 78 Actuators/regulations 79 How to exit the program 80 AUTO-DIAGNOSIS FOR E-OBD STANDARD Icon and command window description Program description Engineering parameters Activations 82 82 83 86 87

AXONE 2000 Motor Truck

III

Iso PC-CONNECTION E-MAIL ARCHIVING LIST OF CONNECTING ERRORS

88 89 91 94 98

IV

AXONE 2000 Motor Truck

GENERAL SAFETY PRECAUTIONS


Carefully read the instructions on set up, use and maintenance in this operating manual. Do not allow unskilled personnel to use this machine as this could cause injury to personnel and damage to the equipment. The working area must be dry, ventilated and with enough light. In particular, all car testing with running engine must take place in areas equipped with exhaust fans. Please remember that inhalation of carbon dioxide (odorless) is a health hazard.

When operating on engines or other parts of vehicles:


- Use proper clothing and act appropriately in order to avoid accidents. - Before starting make sure that the vehicle gears is neutral (or park if equipped with automatic gearbox), pull the vehicles hand brake and check that the wheels are blocked. - Protect your face, hands and feet and avoid contact with hot parts such as sparking plugs, exhaust pipes, radiators, and connectors of the cooling system. - Do not smoke and do not use flames while working on the vehicle. - Check that all electric connections are isolated and firm. - Do not look directly into the carburetor inlet while the engine is running. - Keep hands and hair away from moving parts. Do not wear ties, slack clothing, wrist jewelry and watches while working on a vehicle, especially with running engine. - Keep away from the fan. The cooling fan is controlled

by a temperature switch linked with temperature of the coolant: disconnect the fan cable whenever operating on a warm engine, so that the fan does not suddenly start up after the engine has been turned off. - Do not pour fuel directly into the carburetor to start the engine quicker. - Do not touch high-tension cables while the engine is on. - Do not open the radiator cap before both the temperature of the engine and the pressure of the cooling system have decreased. - Handle portable lamps with care and use only safety models. - Wear safety goggles to protect your eyes from fuel, dust and metal. When operating on car batteries, remember that: Car batteries contain sulfuric acid and produce explosive gases. Therefore, keep the following in mind: - Always wear safety goggles. - Do not leave tools on batteries because they could cause unwanted electric connection. - Before testing or charging, cover the battery inlets with a wet rag to choke the explosive gases. - Avoid sparks when connecting the cables with the battery. - Avoid squirts of electrolyte on your skin, eyes and clothing, because it is corrosive and highly toxic. When operating with instruments connected to mains, remember to: - Check that the instrument has been grounded. - Turn off power before connecting or disconnecting cables. - Avoid contact with wet hands. - Isolate yourself from the ground.

HOW TO USE AXONE 2000 Motor Truck CORRECTLY


In order to use AXONE 2000 Motor Truck correctly observe the following safety rules: - The equipment must be placed in a dry area. Do not expose it or use it nearby heat sources. - Turn on and off the equipment only with the ON/OFF switch. - Do not subject AXONE 2000 Motor Truck Central Unit to heavy shock. - Do not expose AXONE 2000 Motor Truck Central Unit to water or other liquids. - Do not lay object on the on the power cable and do not bend it sharply. - For frequent use, store the equipment without disconnecting the power/charge cable. - Disconnect the power/charge cable in case you do not plan to use the equipment for a long time (longer than one month). - Do not use AXONE 2000 Motor Truck with battery charger on. - Do not replace electronic modules (i.e: OBD, ACQ...) with instrument on.

ENVIRONMENTAL INFORMATION
This product may contain substances that can be hazardous to the environment or to human health if it is not disposed of properly. We therefore provide you with the following information to prevent releases of these substances and to improve the use of natural resources.

Electrical and electronic equipments should never be disposed of in the usual municipal waste but must be separately collected for their proper treatment. The crossed-out bin symbol, placed on the product and in this page, remind you of the need to dispose of properly the product at the end of its life. In this way it is possible to prevent that a not specific treatment of the substances contained in these products, or their improper use, or improper use of their parts may be hazardous to the environment or to human health. Furthermore this helps to recover, recycle and reuse many of the materials used in these products. For this purpose the electrical and electronic equipment producers and distributors set up proper collection and treatment systems for these products. At the end of life your product contact your distributor to have information on the collection arrangements. When buying this new product your distributor will also inform you of the possibility to return free of charge another end of life equipment as long as it is of equivalent type and has fulfilled the same functions as the supplied equipment. A disposal of the product different from what described above will be liable to the penalties prescribed by the national provisions in the country where the product is disposed of. We also recommend you to adopt more measures for environment protection: recycling of the internal and external packaging of the product and disposing properly used batteries (if contained in the product). With your help it is possible to reduce the amount of natural resources used to produce electrical and electronic equipments, to minimize the use of landfills for the disposal of the products and to improve the quality of life by preventing that potentially hazardous substances are released in the environment.

DESCRIPTION OF AXONE 2000 Motor Truck

DESCRIPTION OF AXONE 2000 Motor Truck

Top connection Input/output

Back-lit display (320x200) with protective layer Card drive

Plastic foil keyboard

Interface module housing

Battery housing

External power supply Battery recharge Bottom connection Serial/Parallel

DESCRIPTION OF AXONE 2000 Motor Truck

The Keyboard

1. 2. 3. 4.

5.

6. 7.

Contrast key: for adjusting the screen contract together with the vertical movement keys (2) Vertical movement keys: for the cursor vertical movement in order to select the various functions. ENTER key: to confirm the selection. CANCEL key: to cancel the confirmation of the most recently selected function and restore the previous function. Horizontal movement keys: for the horizontal move ment of the cursor, in order to select the various functions. HELP keys: it is used to display an on-line help guide (when provided by the program) Store/delete key: it is used to store the performed test or to delete the data in the memory (depending on the selected program.

DESCRIPTION OF AXONE 2000 Motor Truck

8. 9. 10. 11. 12.

AUX 2 key: to access auxiliary functions AUX 1 key: to access auxiliary functions. Increase/decrease keys. ON/OFF button: to turn on and off the equipment. Numerical keys: they are used to enter codes, numerical data or to select the tests (depending on the selected program).

Every time a key is pressed, the instrument confirms the selection with a beep.

DESCRIPTION OF AXONE 2000 Motor Truck

Interface Module
It is used to allow AXONE 2000 Motor Truck to physically interface with the cables, the sensors and the probes of the various available kits.

Four different interface modules are available OBD-II self-test Measurement Modem (OBD module) (ACQ module) (optional for upgrade by Internet)

Each module is to be used with a specific group of programs. The module is fixed in a dedicated housing on the bottom part of AXONE 2000 Motor Truck. This operation may take place, for the OBD modul, even when AXONE 2000 Motor Truck is working, but is recommendable to replace the modules when the tool if off.

DESCRIPTION OF AXONE 2000 Motor Truck

Card reading and writing unit

The card reading and writing unit (2) accommodates the memory card which contains the diagnostic programs. NOTES: In order to start AXONE 2000 Motor Truck, always insert the memory card. In case it lacks, the screen displays an image inviting to insert the memory card. Insert the memory card with the tool off!

Input-output connectors

NB: The pins identified with (*) are assigned a different use depending on the interface module present in the bottom part of AXONE 2000 Motor Truck.

DESCRIPTION OF AXONE 2000 Motor Truck

1. 2.

3.

POWER connector: to charge the internal battery with the supplied charger. Bottom parallel-serial connection: this connector acts as an interface between AXONE 2000 Motor Truck and the external units such as: the remote terminals, the serial devices, etc. Moreover, it is used to supply AXONE 2000 Motor Truck. Top connector: According to the interface module inserted in the AXONE 2000 Motor Truck bottom housing, it makes it possible to perform all the special of characteristic tests of each AXONE 2000 Motor Truck diagnostics function, using the standard cables provided with all kits.

DESCRIPTION OF AXONE 2000 Motor Truck

AXONE 2000 Motor Truck power supply


AXONE 2000 Motor Truck may be supplied automatically by the internal battery (self-supply) or externally by means of the standard cable. The following connections should be made

- Connect the kit cable (1) to the top connector (2) and then link to the connector (3) as an option: the cable with the cigarette lighter plug (4) or the cable with the battery clamps (5). NB: When AXONE 2000 Motor Truck is supplied by an external source, the internal battery is automatically charged (if required). WARNING: The battery charger cannot be used as external power supply source, but only as external recharging source.

DESCRIPTION OF AXONE 2000 Motor Truck

Battery charge

In order to charge AXONE 2000 Motor Truck internal battery, you must: - Insert the plug (1) into the POWER (2) connector. - Connect the charger (3) to mains with 220 V. When the battery is charged (approx. 12 hours at 20C with efficient battery), the tool internal battery will have a full charge autonomy of over 2 hours. WARNING: The supplied battery charger cannot be used to supply the AXONE 2000 Motor Truck directly, but only to recharge the internal battery.

DESCRIPTION OF AXONE 2000 Motor Truck

Battery change
The battery is located in a housing in the bottom part of AXONE 2000 Motor Truck; in order to open the battery housing entrance door, slightly force the retaining clip placing a sharp object (for example, a screwdriver) in the slot shown by the arrow.

The door will release

and it will be possible to access the battery housing and change the battery. Make sure that the battery plug is conveniently connected as shown on the label located in the battery housing. WARNING: When supplied, the battery is charged but it may exhibit a normal decrease of the charge level. Perform a total recharge of about 12-18 hours before normal use.

10

DESCRIPTION OF AXONE 2000 Motor Truck

NOTES FOR A CORRECT USAGE Make sure the battery is charged


Always use AXONE 2000 Motor Truck with charged battery. In order to maximize the performance, a slow charge should always be preferred. For the efficient battery operation, just follow the simple rules listed below: - The first two charge cycles must be performed with the tool under charge for minimum 12 hours (the night charge is recommended). Afterwards, the charging time may be shorter. However, the battery charge automatically disconnects the supply when the battery has reached the charge complete status. - It is advisable to charge the battery when the charge indicator on the display shows few lines, and the instrument emits sound signals. - Charge at room temperature; if the tool has been exposed to the sun in summer or in a cold place in winter, wait that the room temperature is reached (approx. 20C) before beginning to charge.

Programs check battery charge while running and warn you by flashing the battery icon when power is low. After this the control software allows you to use the instrument for about 10 minutes more and then proceeds with auto-shut down. This function is disabled only when the maximum computing power of the processor is required for instance during fast data acquisition, in such cases the operator is not warned that the battery is almost depleted.

DESCRIPTION OF AXONE 2000 Motor Truck

11

Automatic reset internal fuses


AXONE 2000 Motor Truck is equipped with automatic reset protection fuses. Sometimes, the reset is not immediate and it may be necessary to wait for a few minutes.

TECHNICAL SPECIFICATIONS
The following technical characteristics refer to the use of the AXONE 2000 Motor Truck CPU, those relating to the various programs and the associated interface modules are available in the specific section of each kit. - Self-powered portable computer - Graphic display, with high brightness and contrast (back-lit), resolution 320x200, brightness can be adjusted with the keyboard - Plastic-foil keyboard with touch keys - Internal and external power supply and automatic charge with 12-15 V DC. Internal power supply with fully charged battery > 2 h - 3 standard serial communication port (RS232) - Standard parallel communication port - External software on Memory Card - May be connected in the future with a Hard Disk - Standard PC-CARD type ATA/FLASH card drive - May be connected with a modem or remote terminal - Size: 310 x 140 x 60 mm - Weight: 1.5 kg - Consumption: 10 W - Acceptable temperature range:-5C +40C

12

DESCRIPTION OF AXONE 2000 Motor Truck

SPARE PARTS

1. 2. 3. 4.

(OPTIONAL) Extension cable 7200056 Power supply cable from cigarette ligher 7200032 Battery charger 51VI150 Power supply cable from external battery 7200054

DESCRIPTION OF AXONE 2000 Motor Truck

13

GLOSSARY
- ON LINE HELP: Press the HELP key to get help information. To exit press the CANCEL key. - DATA BASE: set of basic data. - DISPLAY: screen where images are shown. - DRIVE: device which accommodates and reads the memory card. - HARDWARE: all material parts of the computer and peripheral devices connected to it. - MEMORY: an electronic component where all information needed to process data, instructions, intermediate and final results are recorded and stored. - MEMORY CARD: data card which can be inserted into AXONE 2000 Motor Truck drive, data can be read and written on it. - PARALLEL: execution of several tasks at the same time (e.g. transmission of several data at the same time). - PERIPHERAL: external device connected with AXONE 2000 Motor Truck. - SERIAL: execution of operations one after the other (e.g. transmission of several data one after the other). - OPERATING SYSTEM: group of programs which manage resources of AXONE 2000 Motor Truck and other programs. - SOFTWARE: all programs contained in the computer or everything which is not HARDWARE. - CENTRAL UNIT: in a processing system this is the data control center (interpretation and execution of instructions).

14

DESCRIPTION OF AXONE 2000 Motor Truck

GETTING STARTED
AXONE 2000 Motor Truck is a programmable electronic platform; from it, with special kits, you can access the various fields of car diagnostic. When switching AXONE 2000 Motor Truck on, the main menu is displayed to select the group of program related to the required tool.

Use the horizontal movement arrow keys to scroll the icons of the tool/function to be selected and then press the confirmation key (ENTER).

ENGINE DIAGNOSIS

MEASURES

SERVICE

UP-GRADES

DESCRIPTION OF AXONE 2000 Motor Truck

15

PC CONNECTION

DIAGNOSIS FOR E-OBD STANDARD For each diagnostic requirement AXONE 2000 Motor Truck offers a special kit. Each kit includes the tool control program, the interface module (to be located in the bottom part of AXONE 2000 Motor Truck), the sensors, the cables for the connection to the engine, the adaptors, the manual and all what is required by the tools and the specific tests. In order to know if any kit is available contact the licensee for your area.

16

DESCRIPTION OF AXONE 2000 Motor Truck

How to enable a program


At the first AXONE 2000 Motor Truck use attempt, the following entry screen will be displayed to retrieve numbers and letters:

The activation requires the use of a REGISTRATION CODE to be entered as an alphanumerical sequence provided by the reseller, the dealer or others during the first installation or the runoff. When this sequence is completed, all this is conformed by pressing the ENTER key. At this point, AXONE 2000 Motor Truck may be used with access to all the thus validated product functions.

HOW TO USE AXONE 2000 Motor Truck

17

HOW TO USE AXONE 2000 Motor Truck


The instructions refer to the AXONE 2000 Motor Truck CPU; those relating to the various programs are available in the section specific for each kit.

Service programs
From the starting page, you can access the diagnosis and service programs using the arrows keys as described in the previous paragraph.

In order to select SERVICE, move to the SERVICE ICON and press the ENTER key. In this part of the program you can get information on: - Battery - Parallel - Serial - Keyboard - Workshop - Firmware up-grade - Instrument deactivation - Bios upgrading - Instrument reset

18

HOW TO USE AXONE 2000 Motor Truck

KEYBOARD:

It is used to perform a transmission/reception test to check the each key correct operation.

FIRMWARE UP-GRADE:

It is used to up-grade the firmware contained in the interface modules.

HOW TO USE AXONE 2000 Motor Truck

19

OBD Module Updating Procedure (Firmware)


The following screens are displayed when firmware updating function is selected. Follow the guidelines displayed and shown below:

20

HOW TO USE AXONE 2000 Motor Truck

The procedure continues for about 4 minutes and ends with the following two screens.

The OBD module is thus updated.

HOW TO USE AXONE 2000 Motor Truck

21

PARALLEL:

It is used to perform a transmission/reception test to check the parallel port correct operation (using a suitable plug supplied by service centers).

SERIAL:

It is used to perform a transmission/reception test to check the serial port correct operation (using a suitable plug supplied by service centers).

22

HOW TO USE AXONE 2000 Motor Truck

WORKSHOP:

It is used to enter the workshop name that will be displayed on the main screen when AXONE 2000 Motor Truck is switched on.

BATTERY:

It is used to perform a battery charge cycle. The charge curve is stored in the memory card to be displayed later on.

UP-GRADES

23

The remaining items: BIOS UPGRADING, RESET INSTRUMENT and DISABLE INSTRUMENT relate to features reserved to the technical support service and they must not be used by the end user.

UP-GRADES

When accessing this menu, the programs contained in the memory card may be up-graded:

24

UP-GRADES

Internet Connection:

When enabled, this feature can be used referring to the manual supplied with the modem connection module optional kit. The addition of the MDM56 module (modem for Axone2000 V90 56k) and the connection of the supplied telephone cable to the workshop telephone outlet are new, exclusive features of Axone2000 for upgrading and information. To use the functions described below, insert the MDM56 module (with instrument off) in the rear housing of Axone2000. Make sure that the battery is charged, or proceed to use the functions described below after recharging (12 h). This ensures a safer operation of all e-mail and upgrading features. The communication programs used with the Connector kit check the battery status before any connection. In case of low battery, the program reports the system critical status. Other consumption saving strategies are activated by the program, which will turn the Axone2000 screen back-lighting off during longer connectionsessions than a certain time interval. The screen automatically turns on at the end of the transfer, or pressing any key of Axone2000. This situation is also signaled by a sound signal.

UP-GRADES

25

WARNING Do not feed Axone2000 with the supplied battery charger, since such battery charger must only be used for recharge. It cannot power the instrument on, or it may be damaged. Connect the supplied telephone cable to the upper connector of Axone2000 and connect the plug to the workshop telephone outlet. Follow the procedures indicated below for the various resources available in the new software version 7.0.0. WARNING The first time you use email or updating programs, you will be prompted by Axone2000 to enter a telephone number. This operation is only needed once, since the number is automatically stored by Axone2000. This operation is performed by the retailers technician. In case of connection problems depending on the presence of PBX or more complex solutions than those normally present in a normal direct telephone outlet, contact the technical service of your retailer. In case of workshop transfer, inform your retailer so as to change the telephone number previously stored in Axone2000, if needed.

26

UP-GRADES

Online Internet Updating


Texa informs its subscribing customers that updates are available through its retailers, or by sending a short warning message to their mobile phone.

The updating procedure provides for the insertion of the MDM56 communication module, and the connection of AXONE 2000 Motor Truck to a telephone outlet through the supplied cable. Then, select Upgrading from the main menu.

UP-GRADES

27

In the following submenu, select Internet solution, that directly takes you to the page relating to the connection wizard.

The following sequence proposes all steps of the updating wizard:

28

UP-GRADES

After selecting Connect to the Internet from the Options menu, the program starts the connection. Connection is confirmed by the icons in the upper toolbar:

A message in the upper window shows Connected and the connection speed (depending on the quality of communication lines). The first step ends with the detection of the programs available at TEXA, and with the comparison of versions performed between the programs available at Texa and those contained in Axone.

UP-GRADES

29

The next screen displays the available programs, which can be selected and downloaded to the AXONE 2000 Motor Truck memory card. In the example, the technician selects the Self-diagnosis program. The program automatically connects to the file Transfer Service and authenticates the request (checking the subscription validity).

30

UP-GRADES

Once product and user have been identified, the program starts downloading the new version of the self-diagnosis program to the AXONE 2000 Motor Truck memory card. The lower toolbars show the upgrading progress referred to the current, partial and total file.

UP-GRADES

31

When the upgrading is complete, the program ends the connection and restarts AXONE 2000 Motor Truck.

AXONE 2000 Motor Truck is now upgraded.

32

UP-GRADES

MEASURES

33

MEASURES

CAUTION: If it is not expressively stated, the diagnostic features are intended to be useable on 12V-supplied systems only.

MULTIMETER
Texts and images used as an example refer to the use of program by means of BICOR current clamp. The main menu gives access to this function. To select the Multimeter function, move to the corresponding icon and press the ENTER key.

34

MEASURES

N.B. The multimeter function is used for measuring: voltage, current and resistance. The measurement of current, in particular, may be set with different scales: Up to 2A (end of scale), the original cables of the kit may be used. From 20A to 600A, use the BICOR model amperometric clamp, which is not included.

VOLTMETER

Three instruments are available: Voltmeter, Ammeter, and Ohmmeter . The first time they are used, an autocalibration procedure is automatically started (the clock icon is temporarily replaced by a flashing CAL script). This is to improve the calibration of the AXONE 2000 Motor Truck unit. The improved calibration will be finally saved only when the selected function is ended. The instrument may then be used in the normal way again. In this stage, short circuit the red prod and the black clamp of the instrument, that are the two input terminals.

MEASURES

35

The main features of the voltmeter measurement are: Automatic scale change Saving the following values: minimum, medium, and maximum Visual representation of the flow of voltage in time Concurrent analog and digital display N.B. Measurements are available only with DC up to 200 Volts.

AMMETER
For tests up to 2A end-of-scale, just select the AMMETER option in the OPTIONS menu. For tests with 20A and 600A scales, use the BICOR amperometric clamp (optional) and set the required scale manually. Follow the instructions of the selected menu:

which will also let you know how to connect the BICOR clamp

36

MEASURES

so that the instrument is set correctly (in the example given, for tests with a scale of 20A)

The main features of the ammeter measurement are: Value saving: minimum, medium, and maximum Visual representation of the resistance in time Concurrent analog and digital display N.B. Measurements are available only in DC (direct current ).

MEASURES

37

OHMMETER
Ohmic tests are performed using the red prod and the black ground clamp. The component to measure is connected between said two ends. . The main features of the ohmmeter measurement are: Automatic scale change Saving of the following values: minimum, medium and maximum Graphic representation of voltage flow in time

Concurrent digital and analog display

38

MEASURES

Continuity Test
This function is used for testing the continuity of an electric circuit:

The symbol of an open switch appears on the display whenever an interruption in the circuit is found. The symbol of a closed switch and a sound alarm are used to confirm the continuity of the circuit.

TO EXIT THE PROGRAM Move to the OUT icon on the display of any program then press the ENTER key to confirm.

MEASURES

39

OSCILLOSCOPE
The main menu gives access to this function. To select the Osciloscope function, move to the corresponding icon and press the ENTER key.

Thus accessing the manual oscilloscope page, whose functional details are given in the following paragraphs.

40 1.

MEASURES

2.

3.

4.

5. 6.

7.

8.

9. 10. 11.

Sound icon: for turning on and off the sound confirmation or alarm signal. To proceed, use the arrow keys to select the sound icon (which will start blinking) and press the ENTER key. Synch. Command: for selecting the type of synchronism (i.e. how to stabilize the waveform on the display). Three types are available: manual, external or internal). The TRIGGER EXT is only enabled by the program. Values window: shows the values found by the cursors on the measurement graph. To activate reading, select the Cursor option in the Options menu. Navigation windows: for escape from the corrent menu, going directly to to main Oscilloscope Menu. Readings commands: for activating two different types of readings: alternate (AC) or direct (DC). Scale window: for setting the scales of voltage (V) and time (T) according to the signal that must be displayed. Channel window: shows the channel selected (1, 2, 3 or 4) coupled to the red, yellow, green and blue cables, referred to the black power supply clamp of AXONE 2000 Motor Truck (the common ground terminal). Flag icon: used to mark the beginning and the end of measurement. After entering the Manual Function page, the flag icon flashes; to execute the measurement, press the ENTER key. To interrupt the measurement and to freeze the wave form on the display, press the ENTER key again. Options window: for selecting various modes which simplify reading of the signal being measured. Memory window: shows that a signal has been saved. Battery icon: the icon flashes when the battery has nearly run down. In such a case, to continue test- ing, use an external power supply with the supplied cables, or charge AXONE 2000 Motor

MEASURES

41

Truck with the supplied battery charger for a period of time adequate to charge the internal battery.

OPTIONS
To enter the Options area, use the arrow keys on the keyboard until the window border gets fatter and the window starts flashing. Then press the ENTER key.

The Options menu will open. This menu is divided into several functions: INPUT CURSORS ZOOM GRID SCREEN RESET ON-LINE HELP (0)

42

MEASURES

Input

To go to the Input function, press the ENTER key. This activates the possibility of selecting the input channel displayed on the screen.

To select the input channel, use the arrow keys and select the required channel (black border). Then press the ENTER key. ATTENTION: You can select the function with the number keys on the keyboard. Press the number of the corresponding channel.

MEASURES

43

Cursors

To select the Cursors function, move to it with the arrow keys and then press the ENTER key.

In the Cursors function, the window (1) shows the values found on the curve and the letter (A) flashes. It is then possible to position the cursor A on the required point of the displayed curve with the arrow keys.

44

MEASURES

To position cursor B on one point of the curve use the up/down arrow keys to select the letter B. Then use the left/right arrow keys to position the cursor B on the desired point. During these operations, the values concerning voltage and time will be shown point by point. The window (1) will show the values of voltage Va and Vb read at the point where the cursors intersect the curve. The difference in voltage (Dv) and the measurement of the time that separates them (Dt), will be shown in absolute values. Please note that when moving on the curve at the point corresponding to where the signal was read, the color of the intersection point is inverted. This allows an easier and more precise reading. In fact, when the cursor has been placed exactly on the desired point, the original line is canceled and this confirms the right position.

MEASURES

45

Zoom

To enter into the Zoom function, move to the corresponding function and then press the ENTER key.

In the Zoom function, a dotted-border square is shows on the screen which can be moved to the curve section which you want to zoom in (magnify). The square can be moved with the arrow keys. The Zoom magnifies the area within the square. It is also possible to increase or diminish the zoom area with the + and - keys on the keyboard. When the right position has been reached, press the ENTER key. The selected area of the signal will be displayed in the desired size.

46

MEASURES

Grid

This function is used to show or hide the grid lines on the screen. Use the arrow keys to move to the function and then press the ENTER key.

Screen reset

To select the Screen reset function, use the arrow keys to move to the function, and then press ENTER. The signal snapshot on the screen will be canceled and the initial display will be shown.

MEASURES

47

On-line help (0)

To select the On-line help (0) move to the function, then press the ENTER key. A page is displayed which describes the operations to be carried out in order to change the position of the zero potential line. This function allows the display of parts of the signal that would otherwise be left out of the screen.

To return to the page with the display of the signal , press the left arrow key. The zero line can be changed during signal measurement too, just use the + and - keys on the keyboard.

48

MEASURES

SCALE SELECTIONS

The windows with the letters V and T are used to set the voltage and time scales respectively. The grid on the signal display, divides it into many squares, all of the same size. These squares may indicate different measurement units and values. In Manual mode these parameters must be set according to the signal that will be tested so that the best resolution is used for displaying the curve or part of it. This way, the instrument may be used for more rapid and exact measurements.

MEASURES

49

Scale selection (V)

To select the V/div scale, select the window with the letter V (in bold and flashing). Then press ENTER. A list menu will show up with all the values that may be set on the Volt scale. Use the arrow keys to select the required volt/division, and then press ENTER. This way, the new scale will be shown immediately: the axis with the voltage values, will change automatically. It is possible to give each division on the Volts axis a certain voltage value. For example, if each division is set at 0.5 V, the square wave form signal of an optical sensor will be displayed over the entire screen (Fig. 1).

In this case, a part of the signal might stretch beyond the screen and may not be seen. To see the same signal squeezed down to the height of a single square (Fig. 2), simply select a greater value per division (e.g. 5 V).

50

MEASURES

Scale selection (T)


To select the T/div scale, move to the window with the letter T (in bold and flashing), and then press the ENTER key. A list menu will appear with all the values that may be set on the Time scale. Use the arrow keys to move to the required time/division value and press ENTER. The new scale is then immediately shown. The time axis will change automatically.

It is possible to assign each division on the horizontal axis a certain time interval. For example, if each division is set as 5 ms, the signal measured at the ends of an injector will be displayed but not very clearly. This kind of signal lasts less than the setting used, and if the injection time must be tested, no precise measurement will be possible (Fig. 1). To see the same signal completely, clearly and easy to measure, modify the time value per division (e.g. lower to 1 ms per division).

MEASURES

51

Therefore, when selecting the voltage and time measurement scales, it is advisable to adopt the resolution that allows the best visualization of the signal to be measured. This will also allow the best positioning of the measurement cursors.

52

MEASURES

AC/DC READING SELECTION

The two windows with the letters AC and DC may be used for enabling two different measurement modes. If DC is selected, the direct component of the signal will be displayed. If AC is selected, the direct component will be canceled and replaced with the alternate one. This option is extremely useful to highlight the disturbance overlaying a direct signal. A typical example is testing the voltage of a battery. If the test is executed in AC, the reading shows the residual signal generated by the rectifier diodes of the alternator. The measurement with the oscilloscope in AC mode (alternate) allows the selection of small voltage resolution (e.g. 1 V/div), while detecting and displaying a high voltage direct signal .

In the above example (battery check), the positive voltage of 12 - 14.7 V is tested and controlled with a test sensitivity of 1V/division. The resulting oscillogram will show a signal on the zero line with a set of arcades in the positive quadrant (Fig. 1). Such arcades confirms that the alternator and the charging system are in working order.

MEASURES

53

Ac reading selection

To select the alternate current measurement, select the command with the letters AC (in bold and flashing), and then press ENTER.

Dc reading selection

To select the direct current measurement, select the window with the letters DC (in bold and flashing) and then press ENTER.

54

MEASURES

TYPES OF SYNCHRONISM
Synchronism means the way of stabilizing the display of the wave form (signal ) on the screen; an auxiliary signal is used. It may be generated from AXONE 2000 Motor Truck itself (INT), it may be input from the outside (EXT), or it may be generated by the operator (MAN).

The windows for the kind of active synchronism is located on the right of the screen. The synchronism may be of three types: INTERNAL MANUAL EXTERNAL

To select the required type, use the arrow keys to move to it. Then press the ENTER key to confirm.

MEASURES

55

Internal synchronism

The wave form on the display is stabilized with a signal generated by the microprocessor of AXONE 2000 Motor Truck itself. The synchronism may be adjusted in size and position (TRIGGER). To start such adjustment, move to the window with the letters INT and press the ENTER key. The triangles on the V and T axis will flash. While flashing, triangles (1) and (2) may be positioned on the required points by using the arrow keys . In particular, triangle (1) on the V axis represents the level and polarity point in which the connection with the internal synchronism signal will take place. If the triangle is above the zero line, the signal will be displayed starting from its positive phase. If the triangle is below the zero line, the signal will be displayed starting from its negative phase (see diagram on next page).

56

MEASURES

Triangle (2), on the T axis, represents the starting point of the synchronism in the display. Use the arrow keys to move it left or right in order to improve the display of the signal by centering it in the screen. To confirm the selection, press the ENTER key. Signal acquisition will immediately start.

Manual synchronism

To select the Manual synchronism, select the window with the MAN letters. Press ENTER to start measuring of the signal . Manual trigger offers new diagnostic possibilities. While internal or external trigger is as set before, actual signal measurement starts only when the operator presses the ENTER key. The acquired image is saved and then shown on the display. To carry out another measurement, press the

MEASURES

57

ENTER key again. The second measurement will be placed on top of the previous, this way the operator may compare the two test. This function supplies multiple options. For example, it is possible to compare two signal s that have been measured at different revs (injection timing test), or to compare the output signal of a spark knock sensor, with and without knocking. It is possible to carry out this procedure as many times as needed. To avoid confusion and to improve the clearness of the signal s, it is advisable to use the grid-hide option as shown before. To exit this function, just press twice any of the arrow keys.

External synchronism

This mode is not supported by the manual function.

58

MEASURES

AUTO-DIAGNOSIS

59

HOW TO USE THE AUTO-DIAGNOSIS PROGRAM

The AUTODIAGNOSIS program allows AXONE 2000 Motor Truck to be connected to various injection ECUs. CAUTION: While using the tool, especially when the vehicle electronic systems are communicating, never disconnect neither cables nor connections between AXONE2000 Motor Trucks and the vehicle itself. Perform this operation only after the diagnosis procedure is finished. In case of accidental disconnection, switch the instrument off and then on with the system off.

60

AUTO-DIAGNOSIS

In this window you can select the program to run with the up/down keys of the selection menu.

FAST AUTO-DIAGNOSIS
The auto-diagnosis system is based on the exchange of useful information for engine diagnosis, between the vehicles ECU and the connected tester. The quantity and type of available information varies from ECU to ECU. The following functions are available.

Engineering parameters The ECU gives the values shown by the various components of the engine (revs sensor, pressure sensors, temperature, etc.), in real time.

AUTO-DIAGNOSIS

61

Input conditions These represent the status of certain inputs of the ECU: most of them of ON/OFF-type (Engine on/off, Lambda probe on/off, ...).

Saved and current errors The ECU reads any errors found during the use of the engine and, in most systems, stores them in a permanent memory. This way, the operator can see if the problem is occasional (in certain conditions) or if it is always present. The program signals the error and then identifies the type of problem and the probable causes. The operator must then try and solve the problem and then proceed to cancel the error from the ECU memory. If, in following tests, the memory does not contain errors, this means that the problem has been solved. Please keep in mind that in certain ECUs the problems with sensors on the lines connected to the battery are identified only under certain conditions: some only with parked vehicle and dashboard on, others with the engine on or with vehicle moving or after a certain time. The STO function (Automatic Saving/storage) is for used for storing in the memory of AXONE 2000 Motor Truck a certain error that has been canceled or not saved in the ECU. Activation function This function is for activating for a few seconds various components of the engine in order to analyze their operation (injectors, relays, rev counters,...). In some systems the duration of the test may be set by the operator, in others the duration is set by the program resident in the ECU.

62 Regulations

AUTO-DIAGNOSIS

Some systems are supplied with regulations (CO, minimum,...) that can only be used with a system like the ECU probe connected to the diagnostic socket of the ECU. The regulating phases: procedure is usually divided in three

- Access to Regulation function - Adjustment of the preset parameters - Saving of the new regulation.

AUTO-DIAGNOSIS

63

Hot to connect AXONE 2000 Motor Truck to the Electronic Central Unit
How to connect the auto-diagnosis interface cable to AXONE 2000 Motor Truck

a. Link the connector (1) of the auto diagnostics interface cable to the top connector (2) of AXONE 2000 Motor Truck according to the indications on the labels applied to the cable.

64

AUTO-DIAGNOSIS

How to supply power to the Auto-diagnosis interface cable


The auto-diagnosis interface cable cannot be powered by the internal battery of AXONE 2000 Motor Truck. An external power source is required as illustrated: a. By the battery supply cable (1); b. By the cigarette lighter supply cable (2); c. Directly from the auto-diagnosis socket. A special help page will inform the operator if power supply connections must be set up or if the serial connection cable is supplies power too.

AUTO-DIAGNOSIS

65

If the connection is correct, the red LED (1) on the panel of the main cable 3230/CP3 will turn on.

If it will not, check that the poles of the connection cable are correct. Make the connection anyway according to the indications provided by the program, therefore with the tool on. The Line Led comes on when AXONE2000 Motor Trucks and the ECU under test are in communication.

66

AUTO-DIAGNOSIS

Connecting the Auto-Diagnosis socket


Usually each manufacturer has its own auto-diagnosis socket. A special page contains the code of the adapter cable to use for interfacing the auto-diagnosis cable of the vehicle and the main cable 3230/CP5. Connect the Adapter cable to the auto-diagnosis socket on the ECU, as shown in the image in the display, with the suggested connecting cable.

When the connection to the vehicles battery (with the power supply cable) is not necessary, the battery symbol is slashed and the main cable 3230/CP5 is powered through the autodiagnosis socket itself.

AUTO-DIAGNOSIS

67

How to carry out a test


To run the program, select the AUTO-DIAGNOSIS function in the MAIN MENU and then press the ENTER key to confirm.

Function window: shows only the available function system Selection window: shows information concerning the selected system Message window: messages for the operator Diagnosis window information from the computer concerning the selected function

68 1. 2. 3.

AUTO-DIAGNOSIS

4.

5.

OUT box: select this to return to the MAIN MENU. DATABASE box: to choose the type of vehicle and the system to test. ACTIVITY Box: to let the operator know if the com munication between AXONE 2000 Motor Truck and the ECU is active. If it is active the icon will appear as a blinking lamp. BATTERY box: The symbol flashes slowly if the battery is nearly flat; it flashes quickly if the battery has run down. In this case the instrument turns off after 20 seconds. SOUND signal box: to activate or disactivate the sound signal.

How to select make and model


To display the list of available car manufacturers in the message window, select the DATABASE and confirm by pressing the ENTER key.

AUTO-DIAGNOSIS

69

To select the previous itemTo select the next item. Select the car manufacturer and confirm with ENTER.

Select the car model and confirm with ENTER. Select the engine and confirm with ENTER e.g.

Select the system to be diagnosed among the available ones. In fact, many vehicles have various systems, such as: ABS, injection, airbag, GPS etc.

70

AUTO-DIAGNOSIS

In the proposed example, the injection system is selected, then the central unit type/code is selected and all is confirmed by pressing the ENTER key.

Location of ECU and diagnosis socket

After confirmation of the above, the program will show, in the diagnosis window, an image of the adapter cable to use as interface between the vehicles auto-diagnosis cable and the main cable 3151/T01 and its code.

AUTO-DIAGNOSIS

71

(The battery symbol, if shown, indicates that the power supply cable must be connected).

Then the switch position required for the connection will be shown.

ATTENTION: The following are a few examples of operations based on the diagnostic capability of the equipment. Such capabilities may vary according to the type of ECU that has been selected and the data that it is able to supply.

72

AUTO-DIAGNOSIS

Start of diagnosis
After confirming the selection of the system of the vehicle to be tested, the test may be started.

ATTENTION: Before starting the test make sure the dashboard is off. - Set up the connection.

The auto-diagnosis program starts if the cable is connected and powered correctly; the display will show a message like the one in the diagram. (If the connection has not been set up correctly, the message Communication interrupted, reactivate?) - Check the connection to the auto-diagnosis socket of the vehicle.

AUTO-DIAGNOSIS

73

- Switch the dashboard on to activate the communication with the ECU following in the instructions given by the program. - Wait for a few seconds for the communication between the main cable 3250/CP5 and the electronic ECU to be active. After activating the communication, the lamp icon , high up on the right, begins to flash to confirm that the connection has been made. A sound alarm means that errors are present in the memory. In order to display the errors, select the specific page pressing the (+ and -) keys. (See the present and stored errors paragraph).

74

AUTO-DIAGNOSIS

Engineering parameters
ENGINEERING PARAMETERS FUNCTION The display shows a list of some parameters which concern the selected vehicle.The list may be incomplete, to insert the missing items and replace the items shown use the keys right arrows and left arrows.

To display the value of a selected parameter: - Select the parameter. - Press the ENTER key. - To disable the display of the parameter press the ENTER key again.

NOTE: The selected data up-grade speed and the number of available items depend on the ECU.

AUTO-DIAGNOSIS

75

Current and saved errors


Press the keyboard key to access the ERRORS function. In the picture on the right, AXONE 2000 Motor Truck indicates that in the ECU there is a fault concerning the temperature of the engine.

The ATT code next to the signal means that the error is present now, in this moment.

EXAMPLE OF SAVED ERROR: The ECU has found and saved a problem concern ing the engine temperature in the past and which might not exist anymore. The MEM code is shown next to the error message. It is now possible to work on the vehicle to solve the problem.

76

AUTO-DIAGNOSIS

- Press the STORE/DELETE key to delete the detected errors.

- Press the ENTER key to confirm that you want to cancel. Press ESC to cancel the operation. The display will show a message: canceling errors.

AUTO-DIAGNOSIS

77

Sto function (Automatic Saving /Storage)


Deletion of all errors is confirmed by the indica tion STO at the side of the error message. The automatic saving function is used for temporarily storing in AXONE 2000 Motor Truck memory the errors can celed from the ECU memory, in order to read them on the display with the STO code. With canceling, all saved The ATT, MEM and STO error status management depends on the selected system, therefore the behaviour may be different according to the examined system.

78

AUTO-DIAGNOSIS

Input status
As stated above, the Status represents the conditions of certain inputs of the ECU, and mostly ON/OFF (engine on/off, Lambda probe ON/OFF, ...). In certain systems the visual representation of the status is always active. - In order to reach the INPUT STATUS function, repeatedly press the (+) key till the STATUS function is displayed

STATUS FUNCTION

NOTE: The up-grade speed and the number of status depends on the central unit

AUTO-DIAGNOSIS

79

Actuators/regulations
Test of the actuators ATTENTION: This function activates specific components of the vehicle that in certain conditions can be dangerous and cause damage. Use with care. - To access the Actuators function, press the command repeatedly until the ACTUATORS (ACTUATION) function appears.

ACTUATORS FUNCTION

Move to the required ACTUATOR with the keys. Press the ENTER key to activate the selected component. The list may be incomplete, to insert the missing items and replace the items shown use the right and left arrow keys. NOTE: Before entering the ACTUATION page, usually the engine must be off. However, follow the indications provided by the program for systems with a different behaviour.

80

AUTO-DIAGNOSIS

How to exit the program


To exit the active page, press the ESC key until the CONFIRM EXIT message appears.

- Confirm exit by pressing ENTER. - Press any key when the message shown in the second diagram appears. - Press the ESC key repeatedly until the MAIN MENU appears. - To continue the auto-diagnosis, select another vehicle. - To turn the instrument off, use the ON/OFF switch. ATTENTION: We recommend to always use the ESC command to end the procedure in a correct and safe way.

AUTO-DIAGNOSIS

81

82

E-OBD STANDARD AUTO-DIAGNOSIS

AUTO-DIAGNOSIS FOR E-OBD STANDARD

To access the auto-diagnosis features provided by the E-OBD standard, insert the OBD module and select the corresponding program icon in the main page.

Icon and command window description 1


10 11 12

3 4 5

6 7 8

E-OBD STANDARD AUTO-DIAGNOSIS

83

1. 2. 3.

4.

5. 6. 7. 8. 9. 10. 11. 12.

OUT box: select to return to the MAIN MENU. DATABASE box: allows selecting the type of vehicle and the system to diagnose. Activity box: allows detecting whether communication between AXONE 2000 Motor Truck and the ECU is on. In this case, the icon will change into a blinking lamp. Battery box: the symbol blinks slowly when the battery is low; it blinks quickly when the battery is exhausted, and the instrument turns off after 20 seconds. Sound signal box: to activate or deactivate the sound signal. Function window: the function being used is dis played. System selection window: displays information relating to the system. Messages window: displays useful messages for the operator. Diagnosis window: displays information on the selected function from the ECU. Protocol used by the system. Numeric code referred to the diagnosed system. Real or frozen parameters.

Program description
The E-OBD program provides for the switch positioning, the connection to power supply and the key positioning in running position. The E-OBD standard does not provide for the selection of the car brand and model, but it provides for the system automatic recognition of the protocol used by the vehicle.

84

E-OBD STANDARD AUTO-DIAGNOSIS

The program displays a series of messages up to the connection with the ECU, shown by the blinking of the lamp icon.

E-OBD STANDARD AUTO-DIAGNOSIS

85

The program first displays the error page. Possible errors are listed in the lower window table. Select each error to request the display of the help (short description of the error detected) pressing (?).

Press + or - to select the available pages, shown below: - Engineering parameters - Activations - ISO

86

E-OBD STANDARD AUTO-DIAGNOSIS

Engineering parameters
The Engineering parameters page displays in real time the values selected in the lower window list. The displayed values can be edited pressing left and right arrows and confirmed pressing ENTER.

Press (*) to switch from real parameter view to the frozen parameter view. You can open the help for each item proposed by the program when the (?) key is enabled.

E-OBD STANDARD AUTO-DIAGNOSIS

87

Activations
The activations page provides a series of functions, such as: - Reset diagnostic data (error clearing); - Lambda probe test results; - Results of other tests; - Evaporative system tests

Except for the Reset diagnostic data, the other functions are provided by the ECU. Further details can be requested pressing (?).

88

E-OBD STANDARD AUTO-DIAGNOSIS

Iso
The ISO page provides information for: - Vehicle identification (V.I.N); - Identification of software version installed on the ECU (Calibration id.); - Check of memory content, providing a checksum reference number (C.V.N.)

PC CONNECTION

89

PC-CONNECTION
In order to activate the program, place the cursor on the corresponding icon and confirm by pressing the ENTER key.

Thus reaching the following selection menu, providing two different connection modes: - MEASUREMENT - AUTODIAGNOSTICS

Measurement

90

PC CONNECTION

The two procedures are similar and the tool may be used as a data acquisition unit or as an interface by a serial connection to a Pc or to a PEGASO EXPANDER unit. In fact, when executing one of the two programs, the tool turns to the waiting mode and this condition is abandoned when the a communication request is received from the PC. When the communication is activated, the tool screen switches off and turns to the low consumption mode. The use of these programs obviously depends on the availability of a PC or of PEGASO EXPANDER with the dedicated communication software.

E-MAIL

91

E-MAIL
Texa aims at creating a direct channel with its end customers so as to quickly and regularly send all information needed for service. This is obtained thanks to the automatic connection of AXONE 2000 Motor Truck with the Internet and to the transmission - by Texa - of short messages and documents relating to: - Notes on available updates - Technical reports relating to known car failures - Operating notes on the updates - Patches or corrective actions defined by the manufacturers - Information on news - Invitations to presentations or updating courses Technical reports are sent on a weekly basis, or in a specific way based on requirements and availability. The repairer will have the possibility of connecting AXONE 2000 Motor Truck to the telephone line and download the available information using the special kit and selecting E-mail in the main menu.

92

E-MAIL

The e-mail program provides for a series of automatic functions that allow connecting to the Texa plant via the Internet, to download new messages.

E-MAIL

93

The following sequence displays the steps to select and read incoming messages.

94

ARCHIVING

ARCHIVING
The program is provided with advanced features to handle incoming technical notices. Beside reading, the available features are as follows: - Clearing - Printing - Archiving In particular, archiving is provided in the first mail read step, and it can be activated pressing the asterisk key (*) on the AXONE 2000 Motor Truck keyboard. This function allows the automatic information storage, associated to the brand and the electronic control system it refers to. In the example, the operator decides to archive the technical report relating to the remote control synchronization procedure, valid for recent models of the Volkswagen brand. In this way, the information is saved to the memory card of Axone in a specific folder relating to Volkswagen technical reports for the comfort system. Now, the information can be read at a later time, without any telephone connection, using the archive browsing program described below. You can access the archive browsing program from the main menu, where you will find all messages and documents received via e-mail and saved by the repairer. The program allows selecting the topic category for which you are searching information. The following categories are available: Technical reports (all technical cards and documents relating to practical fixing problems). Contents can be generic or specific, and they can relate to both functions and useful news on the AXONE 2000 Motor Truck programs, and fixing information or notices on known failures of a certain vehicle model. - News (all market news relating to the TEXA production)

ARCHIVING

95

- Meetings (dates, places and topics relating to exhibitions, conventions, presentations, etc.) - Training courses (dates, places and topics of available training courses).

Technical reports are sent on a weekly basis, or in a specific way based on requirements and availability. The repairer will have the possibility of connecting AXONE 2000 Motor Truck to the telephone line and download the available information using the special kit and selecting E-mail in the main menu.

96

ARCHIVING

In the main menu, select the E-mail archive program:

In the archive menu, select the category, in this case Technical reports, and select the specific car brand.

ARCHIVING

97

The folders are divided according to the electronic control system.

Enter the specific archive and scroll all technical reports on the specific topic. The item contained in the document is described on top. When you find the report you were searching, confirm selection pressing enter, to view and read the document. After reading, you can now print, delete or keep the document in memory for further use.

98

ARCHIVING

LIST OF CONNECTION ERRORS


Error 01: Connection internal error. Check the contacts between MDM56 and the instrument, and the connection cables; Perform MODEM TEST in Service Menu. If it is all OK, contact the dealer. Error 02: Modem connection problems. Check the contacts between MDM56 and the instrument and check the connection cables; Perform MODEM TEST in Service Menu. If it is all OK, contact the dealer. Error 03: Telephone line problems. Check for line signal; check the connection number dialled by the instrument is correct. Contact your dealer to check the number dialled by the instrument. Error 04: ISP access problems. Check the contacts between MDM56 and the connection cables; check the connection number dialled by the instrument is correct. Contact your dealer to check the number dialled by the instrument. Error 05: Connection end problems. Switch the instrument off and then on. If the error is shown again, contact your dealer. Error 06: No reply from update service. The connection will be stopped. Possible service interruption due to a temporary pause. Try again later. Error 07: Impossible to connect to update service. The connection will be stopped. Contact your dealers service to check your Internet connection setting. Error 08: Update service unavailable. The connection will be stopped. Possible service interruption due to a temporary pause. Try again later. Error 09: Impossible to reach the update service. The connection will be stopped. Contact your dealers service to check your Internet connection setting. Error 10: Impossible to connect to the file transfer service. Contact your dealers service to check your Internet connection setting. Error 11: Out of memory. Contact your dealers service.

ARCHIVING

99

Error 12: Impossible to connect to the file transfer service. The connection will be stopped. The service is temporarily paused. Try again later. Error 13: No reply from file transfer service. The connection will be stopped. The service is temporarily paused. Try again later. Error 14: Invalid user. Your subscription is either inactive or expired. Contact your dealers service. Error 15: File %s not found by transfer service. Problems in update service. Try again later. Contact your dealers service. Error 16: Error creating data channel. Problems in update service. Try again later. Contact your dealers service. Error 17: Error opening the file. Repeat the update procedure. If the problems persists, contact your dealers service. Error 18: Error connecting to file transfer service. Problems in update service. Try again later. Contact your dealers service. Error 19: No memory card space left. Contact your dealers service. Error 20: Error clearing the file. Repeat the update procedure. If the problems persists, contact your dealers service. Error 21: Update service connection error. The connection will be ended. Problems in update service. Try again later. Contact your dealers service. Error 22: Authentication data error. Problems in update service. Try again later. Contact your dealers service. Error 23: Communication protocol error. The connection will be ended. Problems in update service. Try again later. Contact your dealers service. Error 24: Wrong information about memory structure. Problems in update service. Try again later. Contact your dealers service. Error 25: Configuration file corrupted. Problems in update service. Try again later. Contact your dealers service.