DRAFT SPECIFICATION FOR MSPro460 ROOFING H74 ZINC SHEET COVERINGS / FLASHINGS

To be read in conjunction with Preliminaries / General Conditions


110 Zinc Roofing Roofing System MSPro460 preformed standing seam system manufactured and supplied by: MET-SEAM Ltd. Silverwood Industrial Estate, Craigavon. Co Armagh Tel: +44(0)28 3832 5757 Fax: +44(0)28 3832 5758 18mm WBP plywood MET-SEAM PermoSec underlay installed to manufacturers recommendations. All joints to be taped and sealed. VM Quartz 0.7mm 40mm 460mm joints 10 degrees unless approved by manufacturer Clause 330, See drawing ............... Clause 331, See drawing ............... See drawing ..................... .

Drawing references Base Underlay

Material Thickness Seam Height Vertical joints Pitch Eaves detail Ridge/Hip detail Verge detail Other requirements

210

GUTTERS Drawing references Material Finish Thickness Supplier

Outlet 310 RIDGE Drawing references Material Finish Thickness Supplier

Zambelli VM Quartz VM Quartz 0.7 MET-SEAM Ltd. Silverwood Industrial Estate, Craigavon. Co Armagh Tel: +44(0)28 3832 5757 Fax: +44(0)28 3832 5758

See Drawing ......... VM Quartz Preweathered grey 0.8mm MET-SEAM Ltd. Silverwood Industrial Estate, Craigavon.

Co Armagh Tel: +44(0)28 3832 5757 Fax: +44(0)28 3832 5758 Fixing Capping: Install MSPro460 panels with Z in accordance with the MSPro Installation Guide. Manufactured in same material as roof covering in preformed lengths overlapped and secured

330

EAVES Drawing references Material Finish Thickness Supplier ................... VM Quartz Pre-weathered grey 0.8mm MET-SEAM Ltd. Silverwood Industrial Estate, Craigavon. Co Armagh Tel: +44(0)28 3832 5757 Fax: +44(0)28 3832 5758 Eaves can be subject to severe exposure conditions and should be continuously welted to resist uplift. Roof covering must remain securely welted to the weathering plate at maximum extension in high temperatures. Weathering plate: Cover to roof slope: Projection: .. Not less than 100mm with anticapillary welt at top edge. 25mm for forming into drip welt. Fix to roof slope at 100mm. Fold MSPro410 panels around weathering plate projection and single welt to form a drip in accordance with detail 01 of the MS Profiles Installation Guide.

350

VERGE FLASHINGS

Verge flashings consist of a Z section and cleat. The Z section is fitted to the roof panel independent from the roof structure using pop-rivets while the cleat is fitted to the vertical face of the verge. Both positions are determined by the required dimension of the finished covering .................. VM Quartz Pre-weathered 0.8mm

Drawing references Material Finish Thickness

Manufacturer 410 COVER FLASHINGS Drawing references Material Finish Thickness Manufacturer 510

Met-Seam Ltd. Spec, metal & finish thickness ..

WORKMANSHIP GENERAL MS Profiles system to be installed to provide a secure, free draining and completely waterproof installation. Do not use scribers or other sharp instruments without approval. Leave panels free from ripples, kinks, buckling and cracks. Use hand tools only for folding detail as per installation instruction. Ensure that MS Profile system is fully supported and securely fixed to resist wind uplift and able to accommodate thermal movement without distortion or stress. Ensure that finished work is protected against staining or discolouration by subsequent works. Operatives must be trained in the application of the MSPro system and submit records of their experience to the CA on request. Contact Met-Seam Ltd for MSPro Licensed Installers MET-SEAM Ltd. Silverwood Industrial Estate, Craigavon. Co Armagh Tel: +44(0)28 3832 5757 Fax: +44(0)28 3832 5758 MSPro warranty must be applied in writing to Met-Seam Ltd, prior to the Roof or Cladding construction.

550

LIGHTNING PROTECTION Zinc coverings: Attach the following to a lightning protection system: As required. - Electrical continuity: Provide between zinc strips/ sheets via welting of joints. .

555

LAYOUT Agree setting out of longitudinal seam centres with the CA before beginning work. SUITABILITY OF BASES Bases must be dry and free of dust, debris, grease and other deleterious matter. Laying of MSPro system will be taken as joint acceptance by the Main Contractor and Subcontractor of the suitability of bases.

610

640 TIMBER FOR USE WITH MSPRO .. 650 UNDERLAY Handle carefully to prevent tears and punctures.

Lay onto a dry base and fix edges. Keep underlay dry and cover with the MSPro system at the earliest opportunity. 710 FIXING CLIPS The MSPro stainless steel clip, supplied by MET-SEAM is formed from Gauge 22, Grade 304 Stainless Steel. Each clip must be secured to the roof structure by a minimum of two fixings, each capable of resisting a pullout force of 0.2kN STANDING SEAM JOINT Factory pre-formed MSPro460 interlocking joint. With anti-capillary undercloak and 40mm interlocking overcloak.

830

Notes SAMPLES The appointed cladding contractor is to supply 1No. Free of charge 2.0m x 2.0m sample board of MSPro 460 in VM Quartz zinc when requested. Roof Build Up It is advisable to contact the Insulation supplier for a Condensation Risk Analysis to avoid any condensation issues.