You are on page 1of 4

1

BILL OF QUANTITIES
JAYPEE GREENS,SEC-128 NOIDA U.P,INDIA (SUB-HEAD: FIRE ALARM SYSTEM)

SUMMARY

1.

INTELLIGENT ADDRESSABLE FIRE DETECTION & ALARM SYSTEM TOTAL

Rs. Rs.

13,677,500.00 13,677,500.00

5/5/2012

A.

INTELLIGENT ADDRESSABLE FIRE DETECTION & ALARM SYSTEM INTELLIGENT ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM CONTROL The rate of each item of work for Fire Detection and Alarm System shall also include the following :

1. 2. 3. 4. 5. 6. 7.

All materials, fixing materials, accessories, appliances, tools and equipment. Approved cover plates for inspection, junction and outlet boxes. 2 mm thick outlet boxes and junction boxes. All fixing accessories such as clips, nails, screws etc. Providing and fixing approved saddles, hooks and grouting the same as required, in the case of all exposed conduit work. Embedding conduits and accessories in wall, slabs etc. during construction and / or cutting chases and making good as in the case of all concealed conduit work. Testing and commissioning of each device, circuit as per the requirements of NFPA 72, TAC, local authorities and to be witnessed by / Architect / Consultant. Description INTELLIGENT ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM CONTROL PANELS, MODULES, SENSORS & ALARM INITIATING DEVICES Supply, installation, testing and commissioning of following as per specifications : Unit Qty. Rate (Rs.) Amount (Rs.)

No. 1.

1.

Microprocessor based intelligent and electronically addressable, modular, networkable, 20 loop ( each loop connecting to minimum speakers 125 addressable detector and 125 addressable devices) fire alarm control panel with minimum 960 character LCD display, multiple access levels, event history file in non-volatile memory (EEPROM). The panel shall have a built-in integraded (emergency digital voice evacuation system of same make of fire alarm system with suitable UL listed amplifiers for 220 speakers 1 working + 1 standby mode) as required. The panel shall support programmable relay for controlling lifts, staircase pressurizations fans, lift shaft & lift lobby pressurization fans, toilets exhaust fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump controlled by powerful Boolean logic equation. The panel shall have minimum five independent hazard release circuit built-in the panel. The panel shall have 240 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 60 minutes during emergency condition. The panel shall be UL listed. Tenderer to provide interfacing connectivity (BAC Net gateway) for building management sysem complete as per required. KT-01 to KT-05 KT-06 to KT-10 Set Set 1 1 480,000.00 480,000.00 480,000.00 480,000.00

a) b)

5/5/2012

No. 2.

Description Supply installation, testing and commissioning of public address and talk back system with following items a) 400 watt amplifier (03 Nos.) b) Console rack c) Alarm signal generator d) 20 zone floor selector with all call e) Microphone f) Power supply battery charger and battery. g) Internal wiring charges. h) Output circuit divider. i) Circuit for compatibility for addressable fire alarm system. j) All necessarty control module & other module. k) 40 wat talk back system with all necessary amplifier, power supply, battery charger and battery

Unit

Qty.

Rate (Rs.)

Amount (Rs.)

Nos.

306,000.00

612,000.00

3.

Active Repeater panel with 168 character LCD display with integral power supply complete system function keys for programming and control like system reset, Alarm Acknowledge, Alarm Silence, Trouble Acknowledge etc. as required. Nos Intelligent Fault isolator module with integral microprocessor for isolating shorted, dewired and loose circuits between two successive fault with automatic resetting arrangement. Nos Intelligent Addressable monitoring module to connect NO/NC contacts such as pressure switch, flow switches, fire pump contacts (provided by Fire fighting contractor). However testing and commissioning shall be included in the fire detection and alarm system contractor scope. Set Intelligent and electronically addressable photoelectric smoke detector with microprocessor in head and including mounting base with LED etc. complete as per specification. Nos Intelligent and electronically addressable, rate of rise cum fixed temperature thermistor type heat detector with mounting base, LED, fixed temperature setting as per specification. Nos Intelligent Addressable Manual Call point (Break Glass Type) with integral microprocessor and press to talk facility Nos complete soft address as per specifications. 4 watt Fire Hooter cum speaker of same make as fire panel. Nos

34,500.00

69,000.00

4.

200

1,650.00

330,000.00

5.

R.O.

2,150.00

6.

3200

1,925.00

6,160,000.00

7.

700

1,925.00

1,347,500.00

8.

440

3,250.00

1,430,000.00

9.

440

650.00

286,000.00

10.

Supply and fixing of 16 gauge MS conduits in following sizes including cost of junction boxes, bends, elbows, sockets, tees and GI flexible conduit to connect from ceiling to false ceiling etc. laying in slab, cutting chases and making good or surface mounted including all fixing hardware.

a. b. 11.

20 mm dia 25 mm dia Supplying, installing, testing & commissioning of copper conductor PVC insulated FRLS wires for fire detection and alarm system in existing conduit. 2 C x 1.5 sq.mm

RM RM

28000 1500

35.00 42.00

980,000.00 63,000.00

a.

RM

40000

29.00

1,160,000.00

5/5/2012

No. 12.

Description Supplying, Installing, Testing & Commissioning of the Graphic Central Control Stations consisting of the following :

Unit

Qty.

Rate (Rs.)

Amount (Rs.)

a.

Pentium P 4 Duo Machine as per specification with cordles mouse and cordless keyboard as per specification or as Nos. compatible to fire graphics software. 21" color monitor specifications. flat screen LCD display as per Nos. Nos.

28,000.00

28,000.00

b.

1 1

22,000.00 55,000.00

22,000.00 55,000.00

c. 13.

Laser Jet Printer (A3 size) as per Specification. Supply, installation, testing and commissioning of grapahical software for Fire Detection and Alarm System to be connected to the main fire alarm panel The software shall be capable of the following function including licence as per specification. Uploading and downloading of information to FACP Graphics including autocad drawings. Detectors information and change of detectors setting. Software as described above. Total Carried to Summary

Set

175,000.00 Rs.

175,000.00 13,677,500.00

5/5/2012