You are on page 1of 20

Motion Analyzer 5.

200 | Release Notes

Changes in Motion Analyzer 5.200 New Product Additions:


1. 2. 3.

Heavy Duty Electric Cylinder with Food Grade White Paint Option MPAI Short stroke (3" travel) actuator MPAR-P actuator series

Other Improvements:
1. 2.

Moment entries moved to life Estimate Page for Electric Cylinders Support of latest Product Selection Guide (2011) for Electric Cylinders (MPAR, TLAR, MPAR-P, MPAI and MPAI-W) only

Motion Analyzer 5.200 Release Notes

New Feature Overview (Motion Analyzer 5.xxx)


New Welcome Screen Professional revised workflow Profile Editor Enhancements and Additional Index types Motor and Drive selection assistants Individual Axis Notes and System Notes Common Operating Conditions License Control SolidWorks Interface Enhancements New Product additions* Other Changes* * Contains updates for Motion Analyzer 5.000, Motion Analyzer 5.100, Motion Analyzer 5.110 and Motion Analyzer 5.200.

Motion Analyzer 5.200 Release Notes

New Feature Details


1. New Welcome Screen a. New: Workflow selections i. Professional New work flow ii. Classic Classic Motion Analyzer work flow iii. Just Quote Select a Bill of Material for Kinetix products b. Open: Open files from your PC. Opens a file search window. c. Recent: Displays a list of recently opened file to click on and open.

Motion Analyzer 5.200 Release Notes

2. Professional Revised Work Flow a. New Work Flow steps i. Load Type ii. Motion Profile Design iii. Mechanism Selection iv. Transmission Selection v. Motor Family Selection vi. Drive Family Selection vii. Search Solution b. Progress Icon Bar i. An Icon bar at the bottom of the screen indicates the work flow progress for the axis being entered.

c. Super Review tab i. Super Review tab displays all motion calculated results in a tabular form for every Profile segment at each point in the mechanical system.

3. Profile Editor Enhancements a. Ability to switch axes while Profile Editor is open

b. Ability to Copy and Paste move profiles between Axes within the Profile Editor

Motion Analyzer 5.200 Release Notes

c. The value of Time (Master) at the cursor position of the Profile Editor Graph is displayed in a new Time label. This label can be used to view the Time (Master) value in MU (or any other time unit).

d. The maximum and minimum velocity constraints of an Index segment can be specified for an Index move. Motion Analyzer will adjust the index segment to restrict the maximum and minimum velocities to within the applied limits. If the user entered limits cannot be supported an error message will be displayed in Profile Editor.

Motion Analyzer 5.200 Release Notes

4. Profile Editor Additional Segment Types a. Index 2 3 Poly (Parabolic) i. This move type is not supported in RSLogix 5000 natively. Motion Analyzer Profile Editor is used to build the cam, and then it can be exported to the RSLogix 5000 Cam editor in a MATC or MAPC instruction.

b. Index Adjusted Sine (Cycloidal) i. This move type is not supported in RSLogix 5000 natively. Motion Analyzer Profile Editor is used to build the cam, and then it can be exported to the RSLogix 5000 Cam editor in a MATC or MAPC

Motion Analyzer 5.200 Release Notes

instruction. c. Index 4 5 6 7 Polynomial ( 7th order Polynomial) i. This move type is not supported in RSLogix 5000 natively. Motion Analyzer Profile Editor is used to build the cam, and then it can be exported to the RSLogix 5000 Cam editor in a MATC or MAPC instruction.

d. Index Modified Trapezoidal i. This move type is not supported in RSLogix 5000 natively. Motion Analyzer Profile Editor is used to build the cam, and then it can be exported to the RSLogix 5000 Cam editor in a MATC or MAPC instruction.

5. Motor Selection Assistant a. Select from a family of motors that can supply the speed and torque required for your application when using the Professional work flow.

6. Drive Selection Assistant

Motion Analyzer 5.200 Release Notes

a. Select from a family of Drives that are compatible with the Motor Family selected when using the Professional workflow.

7. Axis and System Notes a. Ability to add Axis Notes to each axis in the Motion Analyzer System file. This is in addition to the System Notes that are available.

8. Common Operating Conditions

Motion Analyzer 5.200 Release Notes

a. Common Operating Conditions b. Individual operating conditions for L10 Life Calculations and Power Supply Energy Estimate calculations have been moved to a common location.

9. License Control

Motion Analyzer 5.200 Release Notes

a. Registration has been implemented for the Full version of Motion Analyzer 5.xxx. If you do not wish to register you will be able to use Motion Analyzer 5.xxx in a Lite version, which has limited functionality. b. Registration can be accomplished via Online registration or Offline (email) registration.

10. My Preferred Database a. Mark Standard Database name has been changed to My Preferred Database. Use this to predefine motors and drives that are searched through for a solution.

Motion Analyzer 5.200 Release Notes

10

Motion Analyzer 5.200 Release Notes

11

11. SolidWorks Interface Enhancements a. SolidWorks Model must be open in SolidWorks when launching Simulation tools from Motion Analyzer. b. SolidWorks Motion Study must be set up when launching Simulation tools gravity, SolidWorks motors, velocity and force/torque results plots, and any additional external forces must be defined. c. For single axis or independent axis of motion, enter data into Motion Analyzer axis, selecting From SolidWorks as your load type. In the axis, you may reverse your motion profiles in order to drive velocity in the correct direction on the model, and again if necessary to make the returned data align with the original defined motion profile.

Motion Analyzer 5.200 Release Notes

12

d. For interdependent axis of motion, you must define profile data and launch the SolidWorks Simulation tool from the System View page. You may reverse your motion profile in order to drive velocity in the correct direction on the model.

Motion Analyzer 5.200 Release Notes

13

New Product Details Motion Analyzer 5.000


1. Kinetix 3 Drive products 2. MPAI Heavy Duty Electric Cylinders 3. Support for Kinetix 6200_6500, Kinetix 300 families in Just Quote mode. 4. Support for RDD, MPM, LDC and LDL Motor series in Just Quote.

5. Support for MPAI and MPMA Actuator Series in Just Quote.

Motion Analyzer 5.100


1. Incorporation of Medusa Cables 2. Shimpo Gearboxes added 3. Alpha TPA+ gearboxes added 4. Alpha CP gearboxes restored 5. HPK-B2510C motor added 6. Low voltage support added for PowerFlex 70 and PowerFlex 700. This is for information purpose only. Low Voltage Motor Series is not available for PowerFlex 70 and PowerFlex 700. 7. New Inertia unit Kg-mm2 added 8. Brake rating has been updated for all Motors. Brake option and inertia data has been updated for all HPK motors.

Motion Analyzer 5.200 Release Notes

14

9. ENDAT associated Control System updates for Kinetix 6200 & 6500, Kinetix 300 and Kinetix 350 family. 10. Low HP Drives have been added for Powerflex 755 family

Motion Analyzer 5.200


1. Heavy Duty Electric Cylinder with Food Grade White Paint Option 2. MPAI Short stroke (3" travel) actuator 3. MPAR-P actuator series

Motion Analyzer 5.200 Release Notes

15

Other Changes Motion Analyzer 5.000


1. Allen-Bradley Integrated Gearmotors have been removed. They have been replaced by Integrated Gearmotors that include Wittenstein / Alpha TPM+ Integrated Gearmotors. 2. Program name has been changed from EzSize.exe to MotionAnalyzer.exe 3. Linear motor magnet track selection has been enhanced. 4. Triangular move type added to the Press Roll Feed template. 5. Brake Selection for Electric Cylinders have been updated. 6. Brake Rating Utilization for Motor 7. Brake Rating Utilization bar graph is added to Motor solution page. This utilization bar graph will show the brake utilization of a Motor. If the Brake rating of the selected is not available in Motion Analyzer database a warning triangle and a message tooltip is displayed in Motion Analyzer.

Motion Analyzer 5.100


1. Units handling error for amplifiers in Manual selection has been corrected. 2. Life calculation for MPAI has been updated.

Motion Analyzer 5.110


1. IAB support in Motion Analyzer for Ethernet Drive Families a. Kinetix 6200 & 6500 b. Kinetix 300 2. Axis Stop Distance and Time calculation issue has been corrected.

Motion Analyzer 5.200 Release Notes

16

Motion Analyzer 5.200


1. Brake handling update for MPAI- Heavy Duty Electric Cylinders and MPAI- Heavy Duty Electric Cylinders with White Paint option. 2. Sage Key Registry Reset Utility incorporated in Installation Setup Script.

Motion Analyzer 5.200 Release Notes

17

Known Limitations
1. PowerFlex drives are not supported by Tuning Simulation or in the Bill of Materials. 2. For application sizing, selection of IAM in Power Supply/Accessories View will be updated in Bill of Materials only after user visits the "Configure Axis BOM" tab of the first axis. 3. Kinetix 300 and Kinetix 3 Tuning Simulation are not supported. 4. Encompass partner products including Wittenstein/Alpha, Stober, Apex, and Shimpo gearboxes and Elwood/Getty Explosion Rated motors are not supported in the Bill of Materials. 5. Consecutive Logix Linear elements are not allowed to be imported into the Logix Elements in Motion Analyzer Profile Editor. 6. CM222 motors are only available as 460 VAC. 7. When analyzing interdependent axis of motion using the SolidWorks Simulation tool from the System View page, you may not reverse the returned data in order to make it align with the original data as you can within an axis. 8. Stacked Stages (MPMA series) is not supported in Professional Mode. 9. On launching the product details catalog on a Windows 7 64 bit machine, the product catalog is opened to the first page as opposed to the page containing the details of the selected product. 10. When a custom motor is defined in Professional sizing mode, select the user defined motor series (My Series) independently. Selecting My Series and another motor family will create issues with voltage selection on the subsequent Drive selection page. 11. Motion Analyzer 5.200 does not correctly analyze the power supply for RPS shunt modules. Evaluation will produce an incorrect zero result.

Motion Analyzer 5.200 Release Notes

18

SolidWorks Requirements
Static Inertia Import SolidWorks 2009 and above SolidWorks Simulation SolidWorks 2009 with SolidWorks Motion add-in On a Windows 7 machine, SolidWorks must be launched as an administrator (CTRL+SHIFT+Right Click -> Run as Administrator option on the shortcut) so as Motion Analyzer connects to the correct instance of SolidWorks.

Motion Analyzer 5.200 Release Notes

19

Motion Analyzer System Requirements


Installing Motion Analyzer 5.200 The Setup program checks for the availability of the minimum requirement of disk space / OS / Display resolution, etc. before continuing. List of various requirements is as follows:
Operating System
The following operating systems are supported: i. Windows 2000 Service Pack 4 Prerequisite: MDAC 2.8 Download link: http://msdn2.microsoft.com/hi-in/data/aa937730(en-us).aspx Windows XP Service Pack 2 (or greater) Windows Vista (32 and 64 Bit) Windows 7 (32 and 64 Bit) Do Not install on Windows 95

ii. iii. iv. v.

Processor
Pentium III Processor (or greater) is recommended.

RAM
Minimum 256 MB RAM is recommended.

Screen Resolution
Supported Screen Resolution is 1024x768 (High color). Setup will check the current screen resolution and will provide a warning if screen resolution is less than 1024x768 pixels.

Browser
Browser should be IE5.5 or higher.

Disk Space
Minimum disk space should be 450 MB.

.NET Framework
Minimum .NET Framework required is 2.0. System requirements for .NET Framework 2.0 are present at following URL: http://www.microsoft.com/downloads/details.aspx?familyid=0856eacb-43624b0d-8edd-aab15c5e04f5&displaylang=en#Requirements

Motion Analyzer 5.200 Release Notes