Professional Documents
Culture Documents
Made in Germany
2010
fluid sensors and diagnostic systems position sensors and object recognition
We reserve the right to make technical alterations without prior notice. 04/10
ifm the company General information List of articles / approvals Inductive sensors Capacitive sensors Cylinder sensors Safety technology Valve sensors Photoelectric sensors infrared / redlight Photoelectric sensors laser Photoelectric sensors fibre optics Photoelectric sensors specific systems Object recognition Encoders Evaluation systems Level sensors Flow sensors Pressure sensors Temperature sensors Diagnostic systems Bus system AS-interface Multicode reading systems RF-identification systems Power supplies Connection technology ifm worldwide addresses
6810 17 39 49 59 65 69 87 93 -
7 9 15 37 47 56 62 67 84 91 98
101 - 106 109 - 112 115 - 119 121 - 125 127 - 135 137 - 150 153 - 164 167 - 180 183 - 188 191 - 206 209 - 211 213 - 216 219 - 222 225 - 234 236 - 237
State-of-the-art communication. With the right address www.ifm.com only a mouse click separates you from the world of automation technology. See the power of our products in interactive representations. Gain an impression with 3-dimension-al views of our units. Download CAD drawings for direct integration in your applications. And one more innovation on the internet: The e-shop already available in many countries. Order online now even faster, more convenient and reliable. We are there for you. Close contact with our customers is part of our success. Therefore we have consistently developed our sales network right from the start. Today ifm electronic is represented in more than 70 countries close to you! With application advice and service at the heart of our operation. For the introduction of new products and technologies we support you with workshops and seminars in our training centres or in your plant.
Security by success. Since its foundation in 1969 ifm electronic has constantly grown, now having more than 3300 employees worldwide, and achieved a turnover of EUR 340 million in 2009. This success gives you the security of having a reliable partner for the implementation of your automation projects. Comprehensive service and a warranty of up to 5 years on standard units are just two examples of this reliability.
500 sales development in million EUR 400 300 200 100 0 1970
1980
1990
2000
www.ifm.com
A sign of innovation.
Not only components. ifm stands for a large range of different sensors and systems for automation. Our range of more than 8000 articles guarantees flexibility and compatibility. So there is always a reliable solution for your automation projects from the individual sensor with practical accessories to the complete system. Availability guaranteed. Your deadlines matter to us. That is why we are constantly optimising our production processes in order to be able to quickly and flexibly produce large quantities at a constantly high quality and to continue to shorten delivery times. Your order is dispatched via our centralised logistics centre reliably and on time. Quality as part of our philosophy. The quality standard of our products is an integral part of our company philosophy. And we guarantee it! So we provide you, the users, with a maximum degree of security: By means of our own production technology, ifm film technology, as well as by means of extensive quality assurance measures such as 100 % final testing. By quality we understand, for example, ecologically conscious production Made in Germany!
The development of innovative products is one of our core competences. Under the name of i-step we have come up with a new product generation which implements sophisticated technologies in industrially compatible and easy to handle products. From high-quality standard solutions to products specially tailored to the requirements of the individual industries from mobile machines to the food industry.
www.ifm.com
General information
www.ifm.com Information around the clock and around the globe in 22 languages on the internet.
Information - product innovations - company news - exhibition info - locations - jobs Documentation - data sheets - operating instructions - manuals - approvals - CAD data Communication* - request for documents - recall service - live advice - newsletter
Selection - interactive product selection aids - configuration tools - data sheet direct Animation - virtual product animations - flash movies (video sequences) Application - applications - product recommendations - calculation aids Transaction* - e-shop processing - e-procurement catalogues - B2B services
www.ifm.com
General information
Secured authentication Customer-related price indication Real time availability check Personal product favourites Online parcel tracking
Individual order history Convenient quick input form Simple order processing Management of shipping addresses Confirmations by e-mail
www.ifm.com
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
AC002S AC004S AC005S AC007S AC009S AC010S AC012S AC015S AC030S AC031S AC032S AC1144 AC1146 AC1147 AC1212 AC1218 AC1220 AC1221 AC1236 AC1244 AC1326 AC1327 AC1337 AC1354 AC1375 AC1376 AC2086 AC2216 AC2225 AC2251 AC2252 AC2254 AC2257 AC2264 AC2411 AC2412 AC2417 AC2451 AC2452 AC2457 AC2729 AC2730 AC2900 AC2904 AC2910 AC2916 AC3000 AC4000 AC4002 AC4007
CE, CUL CE, CUL CE, CUL CE, CUL CE, CRUUS CE, CSA, UL CE CE, CRUUS CE, CUL CE CE CE CE CE CE, CUL CE, CRUUS CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE CE CE CE CE CE, CUL CE, CRUUS
197 197 197 197 197 198 198 198 197 197 197 199 193 193 194 194 194 194 194 194 193 193 193 193 193 193 195 194 193 194 194 194 194 194 195 196 195 195 196 195 194 195
AC4008 AC5000 AC5003 AC5014 AC5015 AC5031 AC5204 AC5208 AC5214 AC5215 AC5222 AC5228 AC5235 AC5246 DD2003 DI0001 DI5001 DI5009 DI6001 DN1030 DN1031 DN2013 DN2014 DN2032 DN2033 DN2035 DN2036 DN3011 DN3012 DTA100 DTA300 DX2003 E10017 E10191 E10200 E10734 E10735 E10736 E10737 E11030 E11031 E11032 E11033 E11034 E11036 E11047 E11048 E11078 E11220 E11221 CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE CE, CUL CE CE CE CE, CUL CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CRUUS, CUL CE, CRUUS, CUL CE, CUL CE, CUL CE CUL CUL
200 196 196 196 196 197, 199 195 195 195 195 195 197 195 197 123 123 123 123 123 221 221 221 221 221 221 221 221 221 221 198, 215 198, 215 123 159, 173, 29 228 228 28 28, 43 124, 28, 44 124, 28, 44 44 44 44 44 44 44 29 29 44 230 230
E11223 E11224 E11232 E11248 E11249 E11495 E11496 E11498 E11499 E11504 E11505 E11508 E11509 E11521 E11530 E11531 E11533 E11534 E11572 E11664 E11697 E11796 E11797 E11798 E11799 E11801 E11816 E11817 E11818 E11819 E11820 E11821 E11822 E11823 E11877 E11914 E11928 E11929 E11958 E11959 E11960 E11961 E12004 E12153 E12208 E12209 E19503 E20004 E20005 E20600 CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS
230 230 111, 228 228 228 230 230 230 230 228 228 227 227 28 29 29 29 29 185 185 228 54 54 54 54 54 53 53 53 53 53 53 53 53 53 54 54 61 54 54 54 54 54 45 67 67 29 77 77 96
CE CE
www.ifm.com
10
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
E20615 E20639 E20718 E20722 E20738 E20765 E20767 E20768 E20773 E20774 E20860 E20861 E20870 E20873 E20874 E20903 E20907 E20911 E20915 E20939 E20941 E20952 E20953 E20954 E20956 E20965 E20969 E20974 E20984 E20993 E20994 E21015 E21084 E21087 E21088 E21117 E21120 E21125 E21126 E21166 E21200 E21237 E2D101 E2D110 E2D200 E2I200 E30006 E30007 E30016 E30017 CE
95 95 29, 44 104, 90 228 96 96 96 96 96 29 29 29, 44 29, 44 29, 44 78 78 78 78 111, 112 111, 211 111 77 77 77 78 78 78, 90 78 89 89 78 79 104, 79 215, 79 79 79 78 78 111, 211 78 78 104, 90 111, 211 111 211 132, 159 132, 160 174 174
E30018 E30047 E30052 E30055 E30056 E30064 E30089 E30090 E30094 E30098 E30104 E30112 E30115 E30116 E30122 E30128 E30393 E30396 E30399 E30400 E30401 E30402 E30403 E33001 E33002 E33201 E33202 E33222 E33401 E33402 E33701 E33702 E33721 E33722 E34410 E35010 E37010 E3D103 E3D200 E40057 E40096 E40099 E40101 E40107 E40114 E40115 E40124 E40128 E40129 E40138 EHEDG, FDA EHEDG, FDA EHEDG, FDA EHEDG EHEDG EHEDG, FDA EHEDG, FDA EHEDG, FDA EHEDG, FDA EHEDG EHEDG CE EHEDG FDA EHEDG EHEDG
174 174 132, 161 174 174 161 174 174 159, 175 185 132, 159 111, 186 187 160 132, 145 161 175 159, 173 132, 159 132, 160 132, 160 132, 160 175 132, 161 161 132, 144 144, 160 144, 160 175 175 132, 144 144, 160 144, 160 145, 160 174 175 175 112 112 144 144, 175 144, 175 144, 174 175 143, 174 143 144, 174 143, 174 144 144
E40189 E40196 E40199 E43201 E43202 E43203 E43204 E43205 E43207 E43208 E43209 E43901 E43903 E43910 E60028 E60033 E60034 E60063 E60064 E7001S E7005S E70062 E70096 E70213 E70230 E70231 E70297 E70320 E70354 E70413 E70454 E73004 E75232 E80302 E80317 E80320 E89005 E89150 EBC027 EBC031 EBC035 ENC02A ENC05A ENC11A EVC002 EVC003 EVC005 EVC006 EVC094 EVC142 CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CE CE CUL CUL CRUUS
145 145 145 131 131 131 131 131 131 131 131 44 45 131 118 118 118 118 118 199 199 200 199 199 198 198 199 199 196, 199 200 196, 199 199 200 200, 215 200, 215 200, 215 123 124 229 229 229 231 231 231 227, 229 227, 229 227, 229 227, 229 228 227
www.ifm.com
11
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
EVC143 EVC145 EVC146 EVC148 EVC149 EVC151 EVC152 EVC154 EVC155 EVT001 EVT002 EVT004 EVT005 EVT007 EVT008 EVT010 EVT013 EVT040 EVT041 EVT042 EVT043 EVT044 EVT058 EVT060 EVT061 EVT062 EVW002 EVW003 EVW005 EVW006 EVW008 EVW009 G1501S G1502S G1503S G2001S GF711S GG711S GI711S ID0013 ID5046 ID5058 ID5059 IE5338 IE5340 IE5343 IE5345 IER200 IF0005 IF0007
CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CE, CUL CE CE, CUL CE CE, CUL CE, CUL CCC, CE CCC, CE, CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCC, CE CCC, CE
227 227 227 227 227 227 227 227 227 230 230 230 230 230 230 231 230 230 230 230 230 230 231 231 231 231 229 229 229 229 229 229 61 61 61 104 61 61 61 21 22 22 25 19 19 19 19 24 20 20
IF502A IFC204 IFC205 IFC206 IFM205 IFM206 IFR200 IFS204 IFS205 IFS208 IFS209 IFT200 IFT202 IFT203 IFT205 IFT206 IFT208 IFT240 IG0011 IG0012 IG509A IGC204 IGC205 IGC206 IGM204 IGM205 IGR200 IGS204 IGS205 IGS208 IGS209 IGT200 IGT202 IGT203 IGT205 IGT206 IGT208 IGT247 II0011 II0012 II501A IIC200 IIC201 IIM208 IIM209 IIR200 IIS204 IIS205 IIS206 IIS207
CE CE, CUL CE, CUL CE, CUL CCC, CE, CUL, E1 CCC, CE, CUL, E1 CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCC, CE, CUL CCC, CE CE CE, CUL CE, CUL CE, CUL CCC, CE, CUL, E1 CCC, CE, CUL, E1 CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL, CCC CE, CUL, CCC CE CE, CUL CE, CUL CCC, CE, CUL, E1 CCC, CE, CUL, E1 CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL
28 23 23 23 24 24 24 21 21 21 21 25 26 25 26 26 26 25 20 20 28 23 23 23 24 24 24 21 21 21 22 26 26 26 26 26 26 25 20 20 28 23 23 24 24 24 22 22 22 22
IIT002 IIT200 IIT202 IIT204 IIT205 IIT207 IIT209 IIT228 IL5020 IM0010 IM0011 IM0049 IM0054 IM5020 IM5037 IM5038 IM503A IM5046 IM504A IM5115 IM5116 IM5117 IM5123 IM5124 IM5126 IM5127 IM5136 IN5121 IN5129 IN5409 IS5026 IS5070 IT5042 IT5043 IV5003 IV5004 IV5025 IY5051 IZ5047 IZ5048 IZ5051 JAT201 KD0009 KD5018 KG0009 KG0010 KG5065 KI0016 KI0020 KI0054
CCC, CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCC, CE, CUL CCC, CE, CUL CCC, CE CCC, CE CE, CUL CCC, CE CCC, CE CE CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE CE CE CE, CUL CE CE, CUL CE, CUL CE CE CE CE CE, CUL CE, CUL CE CE CCC, CE CE CCC, CE CCC, CE CE, CUL CCC, CE, CUL CCC, CE, CUL CE
27 26 27 26 26 27 27 25 19 20 20 21 21 20 20 20 28 20 28 22 22 22 22 22, 25 22, 25 23 22 19 19 67 19 19 19 19 20 20 25 19 19 19 19 23 42 41 41 41 42 41 42 43
www.ifm.com
12
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
KI5001 KI5002 KI5030 KI5082 KI5084 KI5085 KI5087 KQ6001 KQ6003 KQ6005 KX5001 LI5141 LI5142 LI5143 LI5144 LK1022 LK1023 LK1024 LK3122 LK3123 LK3124 LK8122 LK8123 LK8124 LR3000 LR7000 LR8000 MK5100 MK5101 MK5102 MK5103 MK5104 MK5106 MK5107 MK5108 MK5110 MK5111 MK5138 MK5139 MK5140 MK5157 MK5300 MK5301 MK5302 MK5306 MK5307 MR0100 MR0107 N0531A N0532A
CE, CUL CE, CUL CCSAUS, CE, FM, IEC CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCSAUS, CE, FM CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE, CSA, FM, IEC CE, CSA, FM, IEC
41 41 43 42 41 41 41 42 42 42 43 131 131 131 131 129 129 129 129 129 129 129 129 129 129 129 129 51 51 51 51 51 51 51 51 52 52 52 52 52 52 52 53 53 52 53 51 51 28, 43 28, 43
N0534A NF500A NF501A NG500A NG501A NI500A NI501A O1D100 O1D101 O1D103 O1D105 O1D106 O1D155 O1D300 O2D220 O2I100 O3D200 O4E500 O4H500 O4P200 O4P500 O4S500 O5C500 O5E200 O5G500 O5H200 O5H500 O5P200 O5S200 O7E200 O7H200 O7H202 O7H204 O7P200 O7S200 OBF500 OD5005 OD5007 OD5009 OD5011 OD5013 OG0030 OG0033 OG0035 OG0039 OG5123 OG5124 OG5125 OG5126 OG5127
CE, CSA, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE CE CE CE CE, CUL CE CE CE CE CE CCC, CE, CUL CCC, CE CCC, CE CCC, CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL
28, 43 27 27 27 27 27 27 103 89 103 103 103 103 103 111 211 111 77 77 77 77 77 103 76 103 76 76 76 76 76 76 76 76 76 75 95 103 103 104 104 104 73 73 73 73 72 72 72 72 72
OG5128 OG5129 OGE100 OGE200 OGE280 OGE281 OGE500 OGE700 OGH200 OGH280 OGH300 OGH500 OGH580 OGH581 OGH700 OGP100 OGP200 OGP201 OGP280 OGP281 OGP282 OGP300 OGP500 OGP700 OGS100 OGS200 OGS280 OGS500 OGS700 OGT100 OH5003 OH5005 OH5007 OH5011 OH5012 OJ5023 OJ5027 OJ5032 OJ5071 OJ5122 OJ5126 OJ5130 OJ5131 OJ5148 OJ5154 OJ5158 OJ5186 OL0004 OL0005 OL0006
CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCC, CE CCC, CE CE
72 72 71 71 73 73 71 89 71 73 72 72 73 73 89 71 71 71 73 73 73 72 72 89 71 71 73 71 89 71 74 74 74 74 74 74 74 74 74 75 75 74 74 75 89 89 103 75 75 75
www.ifm.com
13
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
OL0007 OO5000 OO5001 OO5002 OO5003 OY120S OY121S OY122S PA3020 PA3021 PA3022 PA3023 PA3024 PA3026 PA3027 PA3028 PA3029 PA3060 PF2652 PF2653 PF2654 PF2656 PF2657 PF2658 PG2451 PG2452 PG2453 PG2454 PG2456 PG2457 PG2458 PG2489 PG2789 PG2793 PG2794 PG2795 PG2796 PG2797 PG2798 PG2799 PI1093 PI1094 PI1095 PI1096 PI1097 PI1099 PI1693 PI1694 PI1695 PI1696
CCC, CE CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE CE CE CE CE CE CE CE CE, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA
75 95 95 95 95 104 104 104 156 156 156 156 156 156 156 130, 156 156 156 158 158 158 158 158 158 158 158 158 158 158 158 158 158 130, 158 158 158 158 130, 158 130, 158 130, 158 130, 158 157 157 157 157 130, 157 130, 157 157 157 157 157
PI1697 PI1698 PI1699 PI2093 PI2094 PI2095 PI2096 PI2097 PI2098 PI2099 PI2789 PI2793 PI2794 PI2795 PI2796 PI2797 PI2798 PI2799 PIM693 PIM694 PK6520 PK6521 PK6522 PK6523 PK6524 PM2053 PM2054 PM2057 PM2058 PMP094 PMP095 PMP096 PMP097 PN2009 PN2020 PN2021 PN2022 PN2023 PN2024 PN2026 PN2027 PN2028 PN2069 PP2001 PQ7809 PQ7834 PS3208 PS3407 PS3417 PT3550
CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE CE CE CE, CUL
157 157 157 157 157 157 157 130, 157 130, 157 130, 157 130, 157 157 157 157 130, 157 130, 157 130, 157 130, 157 158 158 155 155 155 155 155 159 159 159 159 159 159 159 159 155 155 155 155 155 155 155 155 155 129, 155 159 155 155 130, 156 130, 156 130, 156 156
PT3551 PT3552 PT3553 PT3554 PT9550 PT9551 PT9552 PT9553 PT9554 PY2068 RB1015 RB6009 RB6015 RB6029 RM3005 RM7003 RM7004 RN7003 RN7004 RO6344 RO6345 RU1016 RU1025 SD2000 SD5000 SD6000 SD6100 SD8000 SD9000 SF211A SF221A SF320A SF321A SF5200 SF5350 SF5700 SF5800 SF6200 SI5000 SI5004 SI5006 SI5007 SI5010 SI6600 SI6700 SI6800 SL0101 SL5101 SM6050 SM6100
CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL TIIS
156 156 156 156 156 156 156 156 156 129, 155 117 117 117 117 117 118 118 117 117 117 117 117 117 142 142 142 143 142 142 141 141
IEC IEC CUL CUL CUL CUL CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE CE CE, CUL CE, CUL
141 141 140 140 140 140 140 139 139 139 140 139 140 140 140 142 142 139 139
www.ifm.com
14
Order no.
Approvals
Catalogue page
Order no.
Approvals
Catalogue page
SM7100 SM8100 SN0150 SN2301 SN2302 SQ0500 SR0150 SR2301 SR5900 SR5906 SU7000 SU8000 SU9000 TA3130 TA3131 TA3231 TA3430 TA3431 TA3437 TAA131 TAA431 TAD181 TAD981 TAP18A TAP98A TK6130 TK6330 TK7130 TK7330 TK7480 TM0061 TM9550 TN2531 TN7531 TP3237 TR2432 TR7432 TR8430 TS2051 TS2056 TS2229 TS2251 TS2256 TS5051 TT0061 TT1050 TT1061 TT1250 TT2050 TT2081
CE, CUL CE, CUL CE, CUL CE, IEC CE, IEC CE, CUL CE, CUL CE, IEC CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL, EHEDG CE, CUL, EHEDG CE, EHEDG CE, CUL CE, CUL, EHEDG CE, CUL, EHEDG CE, CUL, EHEDG CE, EHEDG, FDA CE, EHEDG, FDA CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CUL, EHEDG CUL CE, CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CUL
139 139 141 142 142 143 141 142 141 141 143 143 143 171 171 172 172 172 172 172 173 173 173 173 173 169 169 169 169 169 170 170 169 169 170 170 170 169 171, 172 171, 172 171 171 171
TT3250 TT5050 VE1001 VE1101 VE113A VKV021 VKV022 VSA001 VSA002 VSA003 VSE002 VSE100
CUL CUL CE, CUL CE, CUL CE, IEC CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL
170 170 185 185 185 185 185 186 186 187 186 186
www.ifm.com
15
16
Inductive sensors
Selection chart
Sensors for industrial applications, DC Sensors for industrial applications, AC and AC/DC Sensors with increased sensing range for industrial automation Photoelectric sensors Sensors for oils and coolants Sensors for oils and coolants with ceramic sensing face Sensors for mobile applications Full-metal sensors with non-stick coating against weld spatter Electromagnetic field immune sensors with correction factor K = 1 Electromagnetic field immune sensors Full-metal sensors for hygienic and wet areas Sensors for hygienic and wet areas with increased sensing range Sensors with ATEX / IECex approval 1D / 1G / 2G Switching amplifiers with ATEX / IECex approval Sensors with ATEX approval 3D Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com
Page
19 20 21 20 21 22 23 23 23 24 24 25 25 25 25 27 27 28 28 28 29 30 31
www.ifm.com
17
Inductive sensors
Inductive proximity sensors for all industries. Wide choice of housing styles and operating voltages. High-quality housing materials. Cylindrical housings from 3 to 34 mm diameter, various rectangular housings. Large supporting range of mounting and wiring accessories.
Inductive sensors In all automated processes sensors are absolutely necessary to provide the PLC with information. They supply the necessary signals on positions, limits or serve as pulse pick-ups for counting tasks or for monitoring rotational speed. Inductive and capacitive sensors are nowadays indispensable for industrial usage. As compared to mechanical switches they offer ideal conditions: non-contact operation free from any wear and tear, high switching frequencies and accuracy. In addition, they are insensitive to vibration, dust and moisture. Inductive sensors detect all metals without contact, capacitive sensors almost all solid and liquid media such as metal, glass, wood, plastic, water, oil, etc. Operating principle of inductive sensors Inductive sensors take advantage of the physical effect of the change in the quality factor in a resonant circuit caused by eddy current losses in conductive materials. This is how it works: A LC tuned circuit generates a high frequency electromagnetic field. This field is radiated from the active face of the sensor. If a conductive material enters this field, eddy currents will be formed in accordance with the law of inductance which draw energy from the oscillator. This reduces the oscillation amplitude. The change is converted into a switching signal. The operating principle permits detection of all metals irrespective of whether they are moving or not. The distance to the active face at which an electrically conductive material causes a change of signal in the sensor is called sensing range. The sensing range of an inductive sensor is defined by means of a target of mild steel (Fe 360). If the switch is damped by other metals, e.g. aluminium or copper, this is reduced. Using correction factors the user can calculate the attainable sensing ranges. Application sensors Every application has its own requirements as regards the sensors to be used. Temperature shocks, mechanical influences or aggressive cleaning agents are just a few of the possible environmental influences to which sensors are subjected. ifm electronic therefore offers inductive sensors which have been developed for special applications. This includes for example the use of selected housing materials such as stainless steel, LCP, PEEK, PBT or Duroplast. An innovative, consistent sealing concept from the sensor to the connector ensures ideal protection against ingress of moisture and aggressive media.
Typical application: Positioning sensing in automation technology; proximity sensors operate reliably and without wear.
High frequency electromagnetic field: The inductive sensor detects all metals.
www.ifm.com
18
Inductive sensors
3 / L = 27 4 / L = 27
1 nf 1.5 nf
10...30 10...30
IP67 IP67
5000 1800
100 100
2 3
IZ5048 IZ5047
M5 / L = 23
0.8 f
stainless steel
10...30
IP65
2000
100
IY5051
6.5 / L = 27
2f
10...30
IP67
1500
100
IT5042
6.5 / L = 27
4 nf
10...30
IP67
500
100
IT5043
M8 / L = 37
5 nf
brass
10...30
IP67
700
100
IE5345
M8 / L = 40
5 nf
10...30
IP67
700
100
10
IE5340
28 x 10 x 16
4 nf
PBT
10...36
IP67
2000
250
12
IS5070
www.ifm.com
19
Inductive sensors
Type
Dimensions [mm]
Material
Ub [V]
Protection
f [Hz]
Iload [mA]
Drawing no.
Order no.
40 x 40 x 120
30 nf
PPE
10...36
IP65
100
250
15
IM5046
M12 / L = 71
4 nf
brass
20...250
IP67
25
250
19
IF0007*
M18 / L = 80
8 nf
brass
20...250
IP67
25 / 50
350 / 100
21
IG0012*
M30 / L = 81
10 f
brass
20...250
IP67
25 / 50
350 / 100
22
II0011*
M30 / L = 81
15 nf
brass
20...250
IP67
25 / 50
350 / 100
23
II0012*
www.ifm.com
20
Inductive sensors
Type
Dimensions [mm]
Material
Ub [V]
Protection
f AC / DC [Hz]
Iload AC / DC [mA]
Drawing no.
Order no.
f = flush / nf = non flush * Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Sensors with increased sensing range for industrial automation
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.
M12 / L = 50
7 nf
brass
10...36
IP67
700
100
28
IFS205
M12 / L = 70
7 nf
brass
10...30
IP67
500
100
30
IFS209
M18 / L = 51
12 nf
brass
10...36
IP67
300
100
32
IGS205
www.ifm.com
21
Inductive sensors
Type
Dimensions [mm]
Material
Ub [V]
Protection
f [Hz]
Iload [mA]
Drawing no.
Order no.
M30 / L = 50
22 nf
brass
10...36
IP67
100
100
36
IIS205
M30 / L = 70
22 nf
brass
10...30
IP67
100
100
38
IIS207
40 x 40 x 54
20 f
PA (polyamide)
10...36
IP67
200
200
40
IM5124
40 x 40 x 54
40 nf
PA (polyamide)
10...36
IP67
60
200
39
IM5136
40 x 40 x 54
40 nf
PA (polyamide)
10...36
IP67
200
200
40
IM5126
92 x 80 x 40
50 f
PPE
10...36
IP67
70
250
41
ID5058
M12 connector Output function normally open / closed programmable) DC PNP Wiring diagram no. 8
105 x 80 x 40 60 nf PPE 10...36 IP67 100 250 42 ID5046
www.ifm.com
22
Inductive sensors
Photoelectric sensors
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.
f = flush / nf = non flush Sensors for oils and coolants with ceramic sensing face
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.
M12 / L = 50
7 nf
brass
10...36
IP68
700
100
28
IFC205
M18 / L = 46 M18 / L = 46
8f 8f
brass brass
10...36 10...36
IP68 IP68
400 400
100 100
31 31
IGC206 IGC204
M18 / L = 51
12 nf
brass
10...36
IP68
300
100
32
IGC205
M30 / L = 50
15 f
brass
10...36
IP68
100
100
35
IIC200
M30 / L = 50
22 nf
brass
10...36
IP68
100
100
36
IIC201
www.ifm.com
23
Inductive sensors
M12 / L = 70
7 nf
stainless steel
10...60
IP67 / IP69K
300
200
46
IFM206
M18 / L = 70
8f
stainless steel
10...60
IP67 / IP69K
200
200
47
IGM204
M18 / L = 70
12 nf
stainless steel
10...60
IP67 / IP69K
200
200
48
IGM205
M30 / L = 70
12 f
stainless steel
10...60
IP67 / IP69K
100
200
37
IIM208
M30 / L = 70
22 nf
stainless steel
10...60
IP67 / IP69K
100
200
38
IIM209
f = flush / nf = non flush Full-metal sensors with non-stick coating against weld spatter
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.
M12 / L = 60
4f
10...36
IP67
100
50
IFR200
M18 / L = 70
6f
10...36
IP67
100
51
IGR200
M30 / L = 70
12 f
10...36
IP67
100
52
IIR200
www.ifm.com
24
Inductive sensors
f = flush / nf = non flush Full-metal sensors for hygienic and wet areas
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.
M18 / L = 70
5f
10...36
IP68 / IP69K
100
100
51
IGT247
M30 / L = 70
10 f
10...36
IP68 / IP69K
50
100
52
IIT228
f = flush / nf = non flush Sensors for hygienic and wet areas with increased sensing range
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.
M12 / L = 50
7 nf
10...36
IP68 / IP69K
800
100
54
IFT200
www.ifm.com
25
Inductive sensors
Type
Dimensions [mm]
Material
Ub [V]
Protection
f [Hz]
Iload [mA]
Drawing no.
Order no.
M12 / L = 70
7 nf
10...30
IP68 / IP69K
700
100
46
IFT202
M12 / L = 61
7 nf
10...36
IP68 / IP69K
800
100
56
IFT208
M18 / L = 51
12 nf
10...36
IP68 / IP69K
300
100
57
IGT200
M18 / L = 70
12 nf
10...30
IP68 / IP69K
300
100
58
IGT202
M18 / L = 62
12 nf
10...36
IP68 / IP69K
300
100
60
IGT208
M30 / L = 50
22 nf
10...36
IP68 / IP69K
100
100
61
IIT200
www.ifm.com
26
Inductive sensors
Type
Dimensions [mm]
Material
Ub [V]
Protection
f [Hz]
Iload [mA]
Drawing no.
Order no.
M30 / L = 59
14 f
10...36
IP68 / IP69K
100
100
64
IIT209
M12 connector Output function Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Wiring diagram no. 11
M12 / L = 45 4f brass 8.2 DC 7.5...30 210 115 700 27 NF501A
M12 / L = 50
7 nf
brass
8.2 DC
7.5...30
210
145
700
28
NF500A
M18 / L = 46
8f
brass
8.2 DC
7.5...30
200
190
400
31
NG501A
M18 / L = 51
12 nf
brass
8.2 DC
7.5...30
200
85
300
32
NG500A
M30 / L = 50
15 f
brass
8.2 DC
7.5...30
230
210
100
35
NI501A
M30 / L = 50
22 nf
brass
8.2 DC
7.5...30
250
120
100
36
NI500A
www.ifm.com
27
Inductive sensors
N0531A
24 24
/ < 50 / < 50
5000 5000
-20...60 -20...60
2 outputs (optocoupler, bipolar, 100 mA, short-circuit protection) 2 transistor outputs PNP (100 mA, shortcircuit protection)
IP20 IP20
65 65
N0532A N0534A
M18 / L = 70
5f
10...36
IP67
100
100
51
IG509A
M30 / L = 70
10 f
10...36
IP67
50
100
66
II501A
E10734
E10735
E10736
E10737
E11521
www.ifm.com
28
Inductive sensors
Type
Description
Order no.
E10017
Mounting clip 12 mm for smooth body switches - 12 mm Form V Housing materials: V4A
E11530
Mounting clip 18 mm for smooth body switches - 18 mm Form V Housing materials: V4A
E11531
Mounting clip Form O for type M12 Housing materials: stainless steel
E11533
Mounting clip Form O for type M18 Housing materials: stainless steel
E11534
Mounting clamp 12 mm with end stop for type M12 Housing materials: PC
E11047
Mounting clamp 18 mm with end stop for type M18 Housing materials: PC
E11048
Mounting set 18.5 mm Clamp mounting free-standing M10 for type OG, IG, KG Housing materials: clamp: diecast zinc / fixture: steel
E20718
Mounting set 12.2 mm Clamp mounting free-standing M8 for type OF, IF Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: diecast zinc
E20860
Mounting set 12.2 mm Clamp mounting free-standing M8 for type OF, IF Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20861
Mounting set 18.5 mm Clamp mounting free-standing M10 for type OG, IG, KG Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20870
Mounting set 30.2 mm Clamp mounting free-standing M12 for type OI, II, KI Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: diecast zinc
E20873
Mounting set 30.2 mm Clamp mounting free-standing M12 for type OI, II, KI Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20874
E19503
www.ifm.com
29
Inductive sensors
Wiring diagrams
1 4 7 10
BN BK BU
L+
BN
L1
3 2
BU
L1 L+ N L
L1 L+
N L
2
1
5
/3 /4
11
L+
BN
L1 L+ N L
1 4 3
L+
L+ 1
BU
3
1 4 2 4: 2: 3 L L+
6
/3 /4
9
1
L+
1: connection to NAMURamplifier
L1 L+ N L
2
4
4: 2:
12
15
BN
L+
BN BK
L+
/3 /4
L+
/4
L+
BK
BU
/3
13
16
AC; DC NPN 1 2 3 4 L 5 1 2 L+ N L+ L1 L AC; DC NPN 1 2 3 4 5 1 2 3 L 4 5 L L+ L1 L N L+
L+
1 4
L+
DC PNP
DC PNP
14
3 4 5
WH
L+
BK
L+
BK
WH
17
L
L+
L+
www.ifm.com
30
Inductive sensors
9
40 32,5 28,5
M8x1 M8x1
16
LED
4 LED 4 x 90 13
2
27 3 17
10
40 32,5 23 8 M8x1 M8x1 4
LED 4 x 90
LED
3
27 4 15,4
13
11
LED
40 20 5
4
23 18 16 M5x0,5
LED
1 IL 5002 IL 5003 5 20 10
LED
8
2,7
M3
5
3,5 LED 27 6,5
1: sensing face 12
16 3,1 5,6 3,5
6
27 3,5 LED 8 6,5
27,8
8 10,4
7
2 35 M8x1
13
16 3,1 5,1 LED
LED
13 5,6 3,5
27
8 M8x1
2,75
4 LED 13
10,4
www.ifm.com
3,1
22,2
27 ,8
2,8
LED 10,2
22,2
2,8
10,2
31
Inductive sensors
18
18 71 60 50
10
4 LED 17
40
3,2
32
18
16
19
18 71 60 46
15
LED LED 121 17
40
101
20
18 80 69 58
27
5,1
5,3
77 10,4
4 LED 24
32
30
21
18 80 69 50
61,5 LED
45,6
16
LED 118 40
4 LED 24
40
22
18 81 67 59
13
5,3
5,3
LED
LED
36
60
46
30
23
18 81 67 44 15
17
LED 118 40 40
29
LED
36
13
5,3
5,3
LED LED
58 7,3
60
46
www.ifm.com
32
30
M30 x1,5
M30 x1,5
58 7,3
M18 x1
M18 x1
M12 x1
1: threaded insert M3, depth 5.8 mm, max. tightening torque 1.2 Nm (screw fixing class 8.8) when brass insert in contact with counterpart.
9
M12 x1
4
3,2
Inductive sensors
28
50 39 32 M12 x1
5 M12 x1 4
34
LED 4 x 90
17
29
70 59 50 M12 x1
30 20
5,4
6 46 61
33
4
LED 4 x 90
17
25
66 40 40
30
70 59 45 M12 x1
5 M12 x1 4
34 M12 x1
17
LED 4 x 90
17
5,4
LED
16
31
46 35 33 30 M12 x1 M18 x1 4 24 51 40 38 25 M12 x1 10 M18 x1 4
LED 4 x 90
30 20
5,4
10
6 46 61
33
26
105 9,3 5,5 40 40 12
LED 4 x 90
32
65 80
18 27
pot. LED
24
65
7,5
16
33 27
45 34 32 M12 x1 M12 x1
M12 x1
70 59 56,5 49
4
LED 4 x 90
17
4 LED 4 x 90 24
www.ifm.com
M18 x1
M12 x1
33
Inductive sensors
39
66 54 46 40
10
40
M18 x1
M12 x1
30 2 5,5
4 LED 4 x 90 24
29,5
35
50 39 37 33 M30 x1,5 M12 x1 30 M12 x1
46
LED 4 x 90
40 36
50 39 37 15 19
5,5
40
66 54 46 40
M30 x1,5
M12 x1
30 2 5,5
LED 4 x 90
36
29,5
46 1
37
70 59 57 53 M30 x1,5 M12 x1
30 M12 x1 5,5
LED 4 x 90
36
38
70 59 57 38 M12 x1
LED 4 x 90
36
5
65 7,5 1 17
65 80
LED
www.ifm.com
34
Inductive sensors
47
70 59 57 50 M12 x1 M18 x1 4 65 80
LED 4 x 90 pot. LED
M12 x1
18 27
24
48
65 7,5 16
43
63 52 43 M12 x1 M12 x1
70 59 57 40 M12 x1
10 M18 x1 4
LED 4 x 90
24
4 LED 4 x 90 17
49
60 49 33 66 54 46 40 M12 x1 M8x1 4 13
44
40
LED 4 x 90
30 2
29,5
50
60 49 40 M12 x1 M12 x1 4
LED 4 x 90
5,5
LED 46
30 M12 x1
17
5,5
51
70 59 57 50
45
70 59 50 M12 x1 M12 x1
M12 x1
LED 4 x 90
24
4 LED 17
52 46
70 59 45 M12 x1
70 58 57 50
M12 x1
M12 x1
4
LED
17
LED 4 x 90
36
www.ifm.com
M30 x1,5
M18 x1
35
Inductive sensors
59
57 39,5 33 29 M18 x1 LED 4 x 90 4 24 62 44,5 38 24 10 M18 x1 LED 4 x 90 4 24 50 39 37 15 18 M30 x1,5 5 36 70 59 57 38 1/2"-20UNF-2A 15 M30 x1,5 36 5 M12 x1
50 37 29 M12 x1
LED 4 x 90
40
40
5
M12 x1
13
5,3
5,3
LED
58 7,3
60
30
60
46
54
50 39 32
61
M12 x1
M12 x1
4
LED 4 x 90
17
55
62
4 LED 17
56
61 44 28 5 5 M12 x1
LED 4 x 90
4 LED 4 x 90 17
63
59 42 35 16 15 M30 x1,5 LED 4 x 90 5 36 59 42 35 31 M30 x1,5 LED 4 x 90 5 36
57
51 40 38 25 M12 x1
10 M18 x1
4
LED 4 x 90
24
64
58
70 59 56 39 M12 x1
10 M18 x1
4
LED 4 x 90
24
www.ifm.com
36
Inductive sensors
66
70 58 57 50
35,5
LED
www.ifm.com
120
LED 4 x 90
36
M30 x1,5
M12 x1
37
38
Capacitive sensors
Selection chart
Sensors for industrial applications, DC Sensors for industrial applications, AC and AC/DC Sensors for the detection of conductive media through a wall Sensors for the detection of granulates Sensors for the detection of granulates Sensors with ATEX approval Switching amplifiers with ATEX approval Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com
Page
41 41 42 42 42 43 43 43 43 45 45 46
www.ifm.com
39
Capacitive sensors
Capactive sensors for detection of non-metalic objects. Sensing range adjustable by means of a potentiometer. Plastic or metal housing for different applications. Housing styles from M12 cylindrical to 105 x 80 mm block. Assortment of tank and sight glass mounting acccessories.
Capacitive sensors Capacitive sensors are used for the non-contact detection of any objects. In contrast to inductive sensors, which only detect metallic objects, capacitive sensors can also detect non-metallic materials. Typical applications are in the wood, paper, glass, plastic, food and chemical industries. In a packaging system, capacitive sensors monitor that the contents of a cardboard box is complete, for example, or check the presence of non-metallic caps. Another application is to monitor the conveying of sheets of glass on a roller conveyor. Operating principle The capacitance between the active electrode of the sensor and the electrical earth potential is evaluated. An approaching object influences the electrical alternating field between these two capacitor plates and, consequently, the capacitance. This applies to metallic and non-metallic objects. By means of the potentiometer or the pushbutton the user can set the sensitivity. Increased noise immunity When detecting objects, very small changes in capacitance must be evaluated and converted into switching signals. This makes high requirements for the electronics. The sensors must be designed so that they are insensitive to fluctuations of the parasitic basic capacitances, as these can amount to a multiple of the change in capacitance to be measured. Moreover, the sensors must be insensitive to electromagnetic interference which typically occur in the application area. ifm electronic has developed future-oriented solutions to meet the high sensor requirements. A patented circuit concept efficiently prevents the mentioned problems and ensures reliable functioning for all relevant noise parameters.
Not only metal: Capacitive sensors detect almost all materials, here for example a log in a saw mill.
www.ifm.com
40
Capacitive sensors
M30 / L = 90
15 nf
10...36
IP65 / IP67
10
100
KI5087
www.ifm.com
41
Capacitive sensors
Type
Dimensions [mm]
Material
Ub [V]
Protection
f AC / DC [Hz]
Iload AC / DC [mA]
Drawing no.
Order no.
f = flush / nf = non flush * Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Sensors for the detection of conductive media through a wall
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.
1x open collector with automatic load detection (DC PNP or DC NPN) Wiring diagram
PBT 10...36 IP65 / IP67 10 100 6 KQ6001
M30 / L = 90
20 nf
PBT
10...36
IP65 / IP67
10
200
KI5082
www.ifm.com
42
Capacitive sensors
f = flush / nf = non flush * Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Sensors with ATEX approval
Type Dimensions [mm] Sensing range [mm] Material Unom. at 1 K [V] Ub [V] Internal capacit. [nF] Internal inductance [H] f [Hz] Drawing no. Order no.
15 nf
PBT
8.2 DC
7.5...15
375
40
KI5030
15 nf
brass
8.2 DC
7.5...15
375
40
10
KX5001
N0531A
24 24
/ < 50 / < 50
5000 5000
-20...60 -20...60
2 outputs (optocoupler, bipolar, 100 mA, short-circuit protection) 2 transistor outputs PNP (100 mA, shortcircuit protection)
IP20 IP20
11 11
N0532A N0534A
Accessories
Type Description Order no.
E10017
E10735
www.ifm.com
43
Capacitive sensors
Type
Description
Order no.
E10736
E10737
E11030
E11031
E11032
E11033
E11034
E11036
Protective cover G 1 for mounting adapter Housing materials: PES black transparent
E11078
Mounting set 18.5 mm Clamp mounting free-standing M10 for type OG, IG, KG Housing materials: clamp: diecast zinc / fixture: steel
E20718
Mounting set 18.5 mm Clamp mounting free-standing M10 for type OG, IG, KG Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20870
Mounting set 30.2 mm Clamp mounting free-standing M12 for type OI, II, KI Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: diecast zinc
E20873
Mounting set 30.2 mm Clamp mounting free-standing M12 for type OI, II, KI Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20874
E43901
www.ifm.com
44
Capacitive sensors
Type
Description
Order no.
E43903
Mounting adapter for free-standing mounting for type KQ Housing materials: adapter: PBT / inserts: brass / screw: steel galvanised Pack quantity: 1
E12153
Wiring diagrams
1 3 5 7
BN BK BU
L+
1
4
L+
BN
L1 L+ N L
BN
BU
BU
BN BK BU
L+
BN
L1 L+ N L
L1 L+ N L
BN
BU
GN/YE
BU
11
AC; DC NPN 1 4 3 L L+ 1 4 3 L L+ 1 2 3 4 5 1 2 L+ N L+ L1 L AC; DC NPN 1 2 3 4 5 1 2 3 L 4 5 L L+ L1 L N L+
DC PNP
DC PNP
10
1 2 3 4 5 L 1 2 3 4 5 L
3 4 5 L+
L+
12
BN BK BU
L+
BN BK
L+
BU
www.ifm.com
45
Capacitive sensors
6
48 43,7 33
M30 x1,5
20
36
5,5 3 2 3,2
LED (4 x 90)
36
M12 x1
24
1: Programming buttons 3
90 77 60 15 M30 x1,5 M12 x 1
LED (4 x 90)
36
1: Programming buttons 4
105 9,3 5,5 40 40 12
18 27
M12 x 1
65 80
pot. LED
10 5
LED pot. 84 58
M18 x1
10 20 LED
pot. LED
41
24
www.ifm.com
46
M34 x1,5
M30
M18 x1
Capacitive sensors
LED
www.ifm.com
120
35,5
47
48
Cylinder sensors
Selection chart
T-slot sensors for industrial applications T-slot reed sensors for industrial applications T-slot sensors for hygienic and wet ares Sensors for short-stroke cylinders Sensors for short-stroke cylinders for hygienic and wet areas Non flush C-slot sensors for industrial applications Accessories Scale drawings - CAD download: www.ifm.com Wiring diagrams
Page
51 51 52 52 52 52 53 53 54 55 55
www.ifm.com
49
Cylinder sensors
Self-clamping fixture for easy adjustment and quick mounting. Convenient: can be easily inserted into the slot from the top. Suitable for almost all C and T slots. Unit versions available with connection cable and M8 / M12 cable plug. Wide selection of adapter accessories.
Cylinder sensors Cylinder sensors are used for position detection of pistons in pneumatic cylinders. They are directly mounted onto the cylinder. The ring magnet attached to the piston is sensed through the housing wall of non-magnetisable material (e.g. aluminium, brass or stainless steel). ifm electronic offers a standard solution for different cylinder types and manufacturers. Operating principle ifms cylinder sensors use state-of-the-art GMR and AMR technology: A GMR element is made up of extremely thin magnetic layers, each separated by a nonmagnetic layer. Without external field they align in an antiparallel manner which results in a defined electrical resistance. If these layers are exposed to a magnetic field, the magnetic layers align in a parallel manner. This results in a large change in resistance that is converted into a switching signal by the internal electronics. An AMR element consists of thin ferromagnetic layers. Electrical resistance is highest without external magnetic fields. The effect of a magnetic field reduces resistance. This change is converted into a switching signal by the internal electronics. Advantage: this method enables exact measurement of even very small changes of the magnetic field where space is extremely limited. This results in a smaller hysteresis and a short travel distance. So, the sensors can be used wherever exact positioning is required (e.g. short-stroke cylinder). Response sensitivity The response sensitivity applies equally to either magnetic polarity and without external field influence. The magnetic flux density in most pneumatic cylinders is between 5 and 25 millitesla (mT). ifm electronics cylinder sensors are factory set so that they detect these magnetic fields safely. Travel distance The travel distance describes the section which is covered by the magnet in the sensing zone. It depends on the strength of the magnet. The short response times of the sensors allow very high travel speeds.
Position sensing: Cylinder sensors monitor the position of the piston in a pneumatic cylinder.
www.ifm.com
50
Cylinder sensors
25 x 5 x 6.5
PA (polyamide)
10...30
> 10000
IP67
100
-25...85
MK5102
25 x 5 x 6.5
PA (polyamide)
10...30
> 10000
IP67
100
-25...85
MK5107
* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 0,175 A (fast acting). Recommendation: check the unit for reliable function after a short circuit.
www.ifm.com
51
Cylinder sensors
25 x 5 x 6.5
PA (polyamide)
10...30
> 6000
IP67
100
-25...85
10
MK5139
www.ifm.com
52
Cylinder sensors
Type
Dimensions [mm]
Material
Ub [V]
f [Hz]
Protection
Iload [mA]
Ta [C]
Drawing no.
Order no.
Accessories
Type Description Order no.
Fixing strap for clean-line cylinders Piston diameter 8...12 mm Piston diameter 8...12 mm for type MKT Housing materials: stainless steel
E11816
Fixing strap for clean-line cylinders Piston diameter 16...20 mm Piston diameter 16...20 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel
E11817
Fixing strap for clean-line cylinders Piston diameter 25...32 mm Piston diameter 25...32 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel
E11818
Fixing strap for clean-line cylinders Piston diameter 40 mm Piston diameter 40 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel
E11819
Fixing strap for clean-line cylinders Piston diameter 50 mm Piston diameter 50 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel
E11820
Fixing strap for clean-line cylinders Piston diameter 63 mm Piston diameter 63 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel
E11821
Fixing strap for clean-line cylinders Piston diameter 80 mm Piston diameter 80 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel
E11822
Fixing strap for clean-line cylinders Piston diameter 100 mm Piston diameter 100 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel
E11823
Adapter for clean-line cylinders for types MKT (T-slot cylinder sensors) Housing materials: stainless steel
E11877
www.ifm.com
53
Cylinder sensors
Type
Description
Order no.
Adapter for tie rod / integrated profile cylinders for types MKT (T-slot cylinder sensors) Clamping range 5...11 mm Housing materials: aluminium / screw: stainless steel
E11797
Adapter for tie rod / integrated profile cylinders for types MKT (T-slot cylinder sensors) Clamping range 9...15 mm Housing materials: aluminium / screw: stainless steel
E11799
Adapter for tie rod / integrated profile cylinders for types MKT (T-slot cylinder sensors) Clamping range 14...20 mm Housing materials: aluminium / screw: stainless steel
E11801
Adapter for trapezoidal slot cylinders for types MKT (T-slot cylinder sensors) Housing materials: aluminium alloy / set screw: stainless steel
E11796
T-slot adapter for C-slot sensor for types MKC (C-slot cylinder sensor) for installation in T-slot cylinders for types MKC (height 5 mm) Housing materials: diecast zinc / fixing element: stainless steel
E11928
T-slot adapter for C-slot sensor for types MKC (C-slot cylinder sensor) for installation in T-slot cylinders for types MKC (height 7.7 mm) Housing materials: diecast zinc / fixing element: stainless steel
E11914
T-slot cylinder memorisation block for types MKT (T-slot cylinder sensors) Housing materials: PA / stainless steel
E11798
C-slot cylinder memorisation block for types MKC (C-slot cylinder sensors) Housing materials: PA / stainless steel
E12004
Clip for types MKT (T-slot cylinder sensors) Piston diameter 16 mm Housing materials: POM / fixture: aluminium / screw: stainless steel
E11958
Clip for types MKT (T-slot cylinder sensors) Piston diameter 20 mm Housing materials: POM / fixture: aluminium / screw: stainless steel
E11959
Clip for types MKT (T-slot cylinder sensors) Piston diameter 25 mm Housing materials: POM / fixture: aluminium / screw: stainless steel
E11960
Clip for types MKT (T-slot cylinder sensors) Piston diameter 12 mm Housing materials: POM / fixture: aluminium / screw: stainless steel
E11961
Clip for types MKT (T-slot cylinder sensors) Piston diameter 16 mm Housing materials: POM / fixture: aluminium / screw: stainless steel
E11958
Clip for types MKT (T-slot cylinder sensors) Piston diameter 20 mm Housing materials: POM / fixture: aluminium / screw: stainless steel
E11959
www.ifm.com
54
Cylinder sensors
Wiring diagrams
1 3 5 7
1 4 3
L+
BN
L+
BN
L1 L+ N L
BN BK BU
L+
BU
BU
BN BK BU
L+
L+
L1 L+ N L
1 4 3
L+
5
1
6,5 5
5,1 2
30,5
5,1
1: Fastening clamp 6
55 5,7 M12 x1 1
6,5 5
5,1 2
30,5
5,1
1: Fastening clamp 7
1 25
5
LED 6,5
55
1 25
LED 6,5
M12 x1
5,1 2
5,1 2
5,1 2
2
5,1
www.ifm.com
55
Cylinder sensors
12
7,7 LED 4,2 2,8 1 2 4,8
5,1 2
5,1 2
www.ifm.com
56
Cylinder sensors
57
58
Safety technology
Selection chart
Fail-safe inductive sensors, 2 x OSSD, to IEC62061 SILcl 2 and ISO13849-1 PL d Safety relays for fail-safe sensors Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com
Page
61 61 61 61 62
www.ifm.com
59
Safety technology
Certified to IEC 61508,SIL 2 / SIL 3 and ISO 13849-1 PL d / e. Safety monitoring of persons and machines. No coded target required for electronic fail-safe sensors. Connection of the sensors to safety PLCs, bus systems and switching devices possible. Series connection of sensors and contacts.
Safety technology Safety technology in automation has a share of the responsibility for safe humanmachine interaction. Fail-safe sensors with safety functions are an important part of a safety system for persons and machines. For the first time, the operating principle and thus the advantages of inductive sensors can also be used for safety applications. Direct detection of metal solves new applications. Up to now magnetic or mechanical counterparts had to be considered in the design. The wear-free non-contact sensing principle and a high protection rating ensure high plant uptime. Connection and evaluation No special demands such as shielding, twisted cables or laying separately, are made on the socket. The sensor is directly connected to existing PLCs or logic modules using common existing unshielded 4-pole cables. The input and output signals of the sensors correspond to DIN EN 61131-2. They are therefore fully compatible with the inputs and outputs of a PLC. Connection to ifm safety relays, AS-i Safety at Work, PROFIsafe, Interbus Safety bus systems or safe PLCs and logic modules is equally simple. For the unit family with dynamic pulse detection the corresponding software modules are required. The fail-safe sensors with 2 x PNP output can be connected to approved two-channel safety relays without cross-monitoring that are suitable for plus-switching noncontact guards. The safety relays from ifm electronic enable functionalities such as two-hand controls to EN 574 or connection of e-stop devices to DIN EN 574-5-1 without extra cost. Operating principle of intelligent electronic fail-safe sensors A magnet or coded target is no longer necessary for the function of the fail-safe sensor. The fail-safe inductive sensor detects metals such as stainless steel or mild steel. The fail-safe sensor operates with an enable zone which is monitored for target position and dwell time.
Limitation of the axis areas of a robot monitored by the GG505S.
Connection of the sensors to safety plcs, bus systems and relays possible.
www.ifm.com
60
Safety technology
70
1...8 nf
19.2...30
IP 65 / IP 67
GG711S
70
1...15 nf
19.2...30
IP 65 / IP 67
GI711S
G1501S
24 DC (19.2...30 DC)
1/2
< 160
0...10
G1502S
24 DC (19.2...30 DC)
1/2
< 100
G1503S
Accessories
Type Description Order no.
Combicon connector with screw terminals 4-pole Housing materials: PA / current carrying parts: copper alloy tin-plated Pack quantity: 5
E11929
Wiring diagrams
1
1 2 3 4
A2 (BK)
www.ifm.com
61
Safety technology
5
50 105
5 M12 x1 4
LED
17
35,5 114
2
70,5 57 35 M12 x1
LED
10 M18 x1 4
LED 2 x 180
24
6
25 105
3
70 57 45 35,5 100 M30x1,5 LED 15 M12x1
LED 4 x 90
36
4
25 105
LED
www.ifm.com
62
35,5
100
Safety technology
63
64
Valve sensors
Selection chart
Sensors for industrial applications Accessories Scale drawings - CAD download: www.ifm.com Wiring diagrams
Page
67 67 67 67
www.ifm.com
65
Valve sensors
Dual inductive feedback sensors for valves and actuators. Straightforward fit to standard actuators. Compact, weatherproof and low maintenance. Optional back wiring option for local solenoid control. Versions for network, hazardous area and conventional wiring.
Valve sensors In industrial processes where liquids, air or gases are used valves are needed for dosing and control. There is a wide variety of valve types; butterfly or ball valves being the most common quarter-turn types. These valves are seldom operated manually. Pneumatic valve actuators are normally used for mechanical positioning. The valve position must be monitored electronically. Mechanical switches are still often used for position feedback on the actuator shaft. For other solutions several proximity sensors are used together with a switch target for position detection. Disadvantage: Mounting is mechanically complex. During switch mounting the signal wires can be reversed when they are connected in the top-mounted junction box. Where there are temperature fluctuations condensing humidity leads to corrosion and thus malfunction. Operating principle An innovative design eliminates the disadvantages of these conventional solutions. In 1992 ifm electronic developed a standard which is now used by many leading actuator manufacturers. A round switch target, known as a puck, with two metal screws offset by 90 is mounted on the actuator shaft. The screws are located at a different height. A compact dual proximity switch (type IND) with two integral sensors detects the upper or lower metal screw depending on the valve position and thus the two switch positions. Due to the simple construction the system operates safely with no wear at all. It is virtually resistant to external influence and meets the protection rating IP 67. Under certain conditions the unit can even be self-cleaning. The sensors are also resistant to mechanical stress such as vibration and shock. Special design AS-i (T5) An extended design is the series T5. In addition to the inductive dual sensor, the unit provides an integrated connection for the solenoid valve. The connection to the control unit is made via a two-wire AS-i cable. The asset: Up to 30 other units can be connected to this line and separately controlled via the AS-i master.
www.ifm.com
66
Valve sensors
E12208
E12209
Wiring diagrams
1
1 2 4 2: 4: A1 A2 3
L+
5 6
IN + IN OUT + OUT -
7
8
1: solenoid valve
6,3
18,8
www.ifm.com
33
67
68
Selection chart
Cylindrical housing OG (M18) BasicLine DC Cylindrical housing OG (M18) PerformanceLine DC Cylindrical housing OG (M18) BasicLine with lateral sensing face Cylindrical housing OG (M18) WetLine for hygienic and wet areas OG housing with rectangular housing Cylindrical housing OG (M18) BasicLine AC/DC Rectangular housing OH for industrial applications Rectangular housing OJ PerformanceLine, lateral sensing face Rectangular housing OL for industrial applications Rectangular housing O7 BasicLine Rectangular housing O5 BasicLine Rectangular housing O5 PerformanceLine Rectangular housing O4 BasicLine Rectangular housing O4 PerformanceLine Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com
Page
71 71 72 72 72 73 73 74 74 75 75 75 76 76 76 77 77 77 79 79 80
www.ifm.com
69
Photocells for general purposes and for harsh environments. Visible red and infrared light sources. Long ranges and accurate background suppression. Choice of standard industrial and high performance units. Accessories for simple fitting and extra mechanical protection.
Photoelectric sensors: infrared / redlight Automation technology can no longer be imagined without photoelectric sensors as artificial eyes. They are used where safe and non-contact detection of the exact position of objects is required. The material of the objects to be detected is of no importance. Compared to proximity sensors photoelectric sensors have a much higher sensing zone. Through-beam sensors A through-beam sensor is distinguished by a long range. The system consists of two separate components: a transmitter and a receiver. The light only travels one way (from the transmitter to the receiver). Adverse effects in the applications, such as dust in the air, dirt on the lenses, steam or mist do not immediately interfere with the system. This is called a high insensitivity to dirt or a high excess gain. Retro-reflective sensors For a retro-reflective sensor the transmitter and receiver are incorporated into one housing. By means of a reflector the transmitted light is returned to the receiver. An object in the beam path interrupts the beam and triggers a switching operation. Retro-reflective sensors without polarisation filter operate in the infrared area, systems with polarisation filter with visible red light. Compared to through-beam sensors, retro-reflective sensors have an average excess gain. Diffuse reflection sensors A diffuse reflection sensor is used for the direct detection of objects. Transmitter and receiver are incorporated into one housing. The transmitter emits light which is reflected by the object to be detected and seen by the receiver. This system evaluates the reflected light of an object. Reflectors are not necessary for operation. Fixing options ifm electronic offers a complete component system of easy-to-use mounting sets. The solutions consist of a clamp which is fastened with only one screw, keeps the sensors safely in place and at the same time guarantees free movement in all axes.
The reflector reflects the light beam: For a retro-reflective sensor transmitter and receiver are integrated into one housing.
Artificial eyes: Photoelectric sensors are used to detect positions in automation technology.
www.ifm.com
70
[V]
Through-beam sensor Type OGE M18 x 1 M12 connector high-grade stainless steel DC
Receiver 20 m D PNP 10...36 1 2 OGE200
Through-beam sensor Type OGS M18 x 1 M12 connector high-grade stainless steel DC
Transmitter 20 m 800 10...36 2 2 OGS200
Retro-reflective sensor Type OGP M18 x 1 M12 connector high-grade stainless steel DC
Polarisation filter Polarisation filter 0.03...4 m 0.03...4 m 160 160 D PNP H PNP 10...36 10...36 1 3 2 2 OGP200 OGP201
Diffuse reflection sensor Type OGH M18 x 1 M12 connector high-grade stainless steel DC
Background suppression 15...250 mm 15 H PNP 10...36 1 4 OGH200
[V]
Through-beam sensor Type OGS M18 x 1 M12 connector high-grade stainless steel DC
Transmitter 25 m 1000 10...36 2 5 OGS500
Through-beam sensor Type OGE M18 x 1 M12 connector high-grade stainless steel DC
Receiver 25 m H/D PNP 10...36 1 6 OGE500
www.ifm.com
71
Type
Operating principle
Sensing range
Ub
Drawing no.
Order no.
[V]
Retro-reflective sensor Type OGP M18 x 1 M12 connector high-grade stainless steel DC
Polarisation filter 0.03...5 m 200 H/D PNP 10...36 1 6 OGP500
Diffuse reflection sensor Type OGH M18 x 1 M12 connector high-grade stainless steel DC
Background suppression 15...300 mm 25 H/D PNP 10...36 1 6 OGH500
[V]
Diffuse reflection sensor Type OGH M12 connector high-grade stainless steel DC
Background suppression Background suppression 100 mm 200 mm < 16 < 28 H PNP H PNP 10...30 10...30 4 4 8 8 OG5123 OG5124
[V]
Retro-reflective sensor Type OGP M18 x 1 M12 connector high-grade stainless steel DC
Polarisation filter 0.03...4 m 160 D PNP 10...36 1 2 OGP300
Diffuse reflection sensor Type OGH M18 x 1 M12 connector high-grade stainless steel DC
Background suppression 100 mm 8 H PNP 10...36 1 9 OGH300
www.ifm.com
72
[V]
[V]
Diffuse reflection sensor Type OGT M18 x 1 1/2 connector plastics AC/DC
Diffuse reflection sensor 1...600 mm < 169 H AC/DC 20...250 10 12 OG0035*
* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit.
www.ifm.com
73
[V]
Diffuse reflection sensor Type OHN Cable with connector 0.2 m plastics DC
Diffuse reflection sensor 2...50 mm 3.5 H PNP 10...30 3 15 OH5005
Diffuse reflection sensor Type OHH Cable with connector 0.2 m plastics DC
Background suppression 1...30 mm 4.5 H PNP 10...30 3 15 OH5007
[V]
www.ifm.com
74
Type
Operating principle
Sensing range
Ub
Drawing no.
Order no.
[V]
[V]
* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 5 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Rectangular housing O7 BasicLine
Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.
[V]
www.ifm.com
75
Type
Operating principle
Sensing range
Ub
Drawing no.
Order no.
[V]
Diffuse reflection sensor Type O7H Cable with connector 0.2 m plastics DC
Background suppression Background suppression Background suppression 1...30 mm 0...50 mm 0...100 mm 2.5 2.5 7 H PNP H PNP H PNP 10...30 10...30 10...30 3 3 3 26 26 26 O7H200 O7H202 O7H204
[V]
[V]
www.ifm.com
76
[V]
[V]
Accessories
Type Description Order no.
Prismatic reflector 25 mm round fixing by screw for type OA, OC, OE, OF, OG, OI, OM, OR, OS, OT, OU Housing materials: plastics
E20953
Prismatic reflector 35 mm round fixing by screw for type OA, OC, OE, OF, OG, OI, OM, OR, OS, OT, OU Housing materials: plastics
E20954
Prismatic reflector 42 mm round for type O5P, OA, OC, OE, OF, OG, OH, OI, OJ, OL, OM, OR, OS, OT, OU Housing materials: plastics
E20004
Prismatic reflector 50 mm round fixing by screw for type OA, OC, OE OF, OG, OH, OI, OJ, OM, OR, OS, OS, OT, OU Housing materials: plastics
E20956
Prismatic reflector 80 mm round for type O4P, O5P, OG, OJ, OA, OC, OE OF, OH, OI, OM, OR, OS, OT, OU Housing materials: plastics
E20005
www.ifm.com
77
Type
Description
Order no.
Mounting set for reflector 25 mm Clamp mounting free-standing M8 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20903
Mounting set for reflector 35 mm Clamp mounting free-standing M8 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20907
Mounting set for reflector 50 mm Clamp mounting free-standing M10 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20911
Mounting set for reflector 80 mm Clamp mounting free-standing M12 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20915
Reflective tape for retro-reflective sensors with polarisation filter TS-02 50 x 1000 mm Housing materials: plastics
E21015
Mounting set 12.2 mm Clamp mounting rod mounting 10 mm for type OF, IF Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: diecast zinc
E21200
Protective bracket for free-standing and rod mounting 18 mm Clamp mounting Housing materials: stainless steel 316L / 1.4404
E21125
Protective bracket for free-standing and rod mounting 18 mm with end stop Mounting clamp Clamp mounting Housing materials: Mounting clamp: PC black / Angle bracket: stainless steel 316L / 1.4404
E21126
E10736
E20965
E20974
E20984
Mounting set OJ for side lens Clamp mounting free-standing M8 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel
E20969
Mounting set O7 Clamp mounting rod mounting 10 mm Housing materials: fixture: stainless steel / clamp: stainless steel / screw: stainless steel / Nut: stainless steel
E21237
www.ifm.com
78
Type
Description
Order no.
Angle bracket for type O5 Housing materials: stainless steel 316Ti / 1.4571
E21087
Mounting set Clamp mounting with protective cover free-standing M10 for type O5 Housing materials: stainless steel 316Ti / 1.4571 / clamp: diecast zinc
E21084
E21088
Angle bracket O4 for type O4 Housing materials: stainless steel 316L / 1.4404
E21120
Angle bracket O4 for type O4 Housing materials: stainless steel 316L / 1.4404
E21117
Wiring diagrams
1 5
1 L+
13
1
4
3
L+
4 2 n.c.
L1
L+
L1 L+
3
L
N L
N L
10
14
1 2 3 4 L1 L+ N L
L+
1 4
L+
L1 L+ N L
11
1
L+
L+
1 4 3
L+
1 4
4
2
2: Teach
4
1 4 2 n.c. 3 L L+
12
1 L+
L+
1 4 3
2
4
2: Teach
www.ifm.com
79
7
44 34 31 27,5
8,2
M18 x1
14,5
16
M12 x1
M18 x1
4 24
34 59,3 70,1
M12 x1 LED 4 x 90
24
2 8
60 49 47 40
M18 x1 13,6
M12 x1
M18 x1
9,7 19 27 62 64 4
24
LED 4 x 90
24
3
1 LED
44 34 31 6,5 21,4
29
75
M12 x1
LED 4 x 90
9
72 61 59 44
M12 x1
M12 x1
24
1: with pot. 4
1 72 61 59 50 44
4
LED 4 x 90
24
10
35,4 15,9 11,5
M18 x1
LEDs
18
M12 x1
52 24,1
M18 x1
4
LED 4 x 90
24
3,3
24
1: with pot. 5 11
72 61 59 34
M12 x1
18
M12 x1
52 24,1
M18 x1
4
LED 4 x 90
LEDs
24
1 3,3 24
6
72 61 59 34
M12 x1
1: setting pushbuttons
M12 x1
4
LED 4 x 90
24
1: Programming buttons
www.ifm.com
80
M18 x1
38
38
M18 x1
M18 x1
17
1 LED 11 7,6 16,6 35 3,1 3,2 M8x1 3,1 8,8 9 LED 3,9 7,6 6,4 12,5 9,6 1 20,6 25,1 3,2 15 4 LED
1 2
4 1 24
1: pushbutton 13
2,9
1: pushbutton 18
14
7,6 LED
3,9
12,5 9,6
24
LED 5
LED 11 8,2
6,4
3,2
1,8 5,3 19
15
2,9
3,5 8,5
M8x1
15
LED 3,9 7,6 5 7,2 20,6 25,1 12,5 9,6
4
11,6
LED
3,2
1: pushbutton 19
1 1 LED 11
15
2,9
16
1 1 24 LED LED 11 8,2
24
LED
5
35
3,5 8,5
1,8 5,3 19
3,1 3,2
45
4
11,6
LED
9 4
1: pushbutton
1 LED
1: pushbutton
www.ifm.com
35
36,5 43,5
35
45
81
24
1 LED 11 26 20,3 2,7 15 LED 9
24
LED
5
35
1,8 5,3 19
3,5 8,5
M8x1
M3
9 4
11,6
25
15 LED 6,5 9
LED
1: pushbutton 21
26 20,3 2,7
M3
LED 27 10
62 49
LED
26
15 LED 7,8 9
31
75
5,5
M3
1: pushbutton 22
1 LED 27 10
LED
27
1
62 49
18,2 6 17
46,8 6,4
6,5
LED
8,6
50
26 20,3 2,7
7,6
14,1
LED 6
5x9
18
25
13 75
5,5
M12 x1
LED
8,6
50
1: pushbutton 23
15 LED 9
LED 15,4
26 20,3 2,7
M3
www.ifm.com
82
14,1
56 70,3
25
31
63,8 27 21,1 8,5 7,9 LED 8,5 5x10
36,5
50,9
25
25
40
56 70,3
M12 x1 M12 x1
32
63,8 27
21,1 8,5
29,5
74,4 86,2
40
25
37
56 70,3
25
7,9
LED
8,5
5x10
40
40
M12 x1
1
3 1 10 8
LED
1: with pot., 2: When a M5 mounting screw is used, the max. tightening torque is 2 Nm. 30
46,8 6,4 6 19,5 1 LED 6 5x9
LED
18,2
25
37
M12 x1
1: Programming buttons, 2: When a M5 mounting screw is used, the max. tightening torque is 2 Nm.
www.ifm.com
56 70,3
25
29,5
74,4 86,2
83
34
63,8 LED 8,5 5x10
40
40
40
74,4 86,2
M12 x1
M12 x1
1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm., 2: Programming buttons
1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm., 2: Programming buttons 35
63,8 27 25,3 8,5 7,9 LED 8,5 5x10
23,5
40
74,4 86,2
40
1 19,7
M12 x1
1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm., 2: Programming buttons
www.ifm.com
84
74,4 86,2
40
85
86
Selection chart
Cylindrical housing OG (M18) Laser PerformanceLine Rectangular housing OJ Laser PerformanceLine, lateral sensing face Rectangular housing O1 Laser PerformanceLine with background suppression Accessories Scale drawings - CAD download: www.ifm.com Wiring diagrams
Page
89 89 89 89 90 90 90
www.ifm.com
87
Safe class 2 laser with visible light for ease of alignment. Detect objects smaller than 1 mm across. Long range versions for measurement up to 60 m. Accurate and repeatable switch point setting. Fine ajustment mounting brackets for easy installation.
Photoelectric sensors: laser Laser systems are used where detection of small objects or precise positioning is required. They are available as through-beam sensors, retro-reflective sensors or diffuse reflection sensors. Laser light consists of light waves of identical length which have a defined phase relation (coherence). This results in an important feature of laser systems, that is the almost parallel light beam. Result: Due to the small angle of divergence long ranges of up to 60 metres can be achieved. The laser spot which is also clearly visible at daylight simplifies the alignment of the system. Apart from the advantages some points have to be taken into account for the selection of the suitable optical system: compared to standard sensors the laser sensors have a reduced temperature range (-10...50 C). In view of the small light spot and the often high ranges the system is more sensitive to vibrations than standard sensors. Mounting aids The ifm laser sensors offer a useful function for easier alignment: The laser power is increased during adjustment: This leads to a particularly bright laser spot which enables safe alignment from a distance even at daylight. How dangerous are laser sensors? Due to the small angle of divergence laser beams are focussed on a small area. The energy and power density on this area is extremely high. ifm laser sensors comply with the European standard EN 60825 or the international standard IEC 60825. These standards describe the operation of laser systems.
Coherent: Laser sensors emit light of a defined wave length and the same phase position.
www.ifm.com
88
[V]
Through-beam sensor Type OGSL M18 x 1 M12 connector high-grade stainless steel DC
Transmitter 60 m 150 10...36 1 1 OGS700
Through-beam sensor Type OGEL M18 x 1 M12 connector high-grade stainless steel DC
Receiver 60 m H/D PNP 10...36 2 2 OGE700
Retro-reflective sensor Type OGPL M18 x 1 M12 connector high-grade stainless steel DC
Polarisation filter 0.2...15 m 40 H/D PNP 10...36 2 2 OGP700
Diffuse reflection sensor Type OGHL M18 x 1 M12 connector high-grade stainless steel DC
Background suppression 20...200 mm 1.2 H/D PNP 10...36 2 2 OGH700
[V]
[V]
Accessories
Type Description Order no.
Prismatic reflector 19 mm round fixing by screw M3 for laser units for type OGPL, OJPL, OLPL Housing materials: screw: stainless steel 316 / 1.4401 / spring washer: stainless steel 316 / 1.4401 / Nut: stainless steel 316 / 1.4401 / front plate: PMMA / base: ABS
E20993
Prismatic reflector 30 x 20 mm angular for laser units for type OGPL, OJPL, OLPL Housing materials: front plate: PMMA / base: ABS
E20994
www.ifm.com
89
Type
Description
Order no.
Prismatic reflector 50 x 50 mm angular for laser sensors and glass / film detection sensors Housing materials: plastics
E20722
E20974
Mounting set Clamp mounting rod mounting 12 mm for type O1D, O2D Housing materials: fixture: stainless steel / clamp: stainless steel / screws: stainless steel / Nut: high-grade stainless steel
E2D101
Wiring diagrams
1 2 3
1
L+
L+
1
4
L+
2
4
2: Teach
3
1 24 LED 5 M18 x1 1 LED 11
M12 x1
9,5 15,5
1,8 5,3 19
4
LED 4 x 90
2
9
72 61 59 34
4
11,6
M12 x1
M18 x1
LED
4
LED 4 x 90
1: pushbutton
24
1: Programming buttons
www.ifm.com
90
36,5 43,5
35
5
1 LED 11
4,5
24
LED
42 30
45
35
3,5 8,5
1,8 5,3 19
M8x1
M12x1 20 25
4
11,6
LED
www.ifm.com
52
45 59
30
91
92
Selection chart
OOF amplifiers for acrylic fibre optics OBF amplifiers for acrylic fibre optics Acrylic fibre optics for OBF / OOF housings, through-beam system Acrylic fibre optics for OBF / OOF housings, diffuse reflection system Acrylic fibre optics for OBF / OOF housings, through-beam system, can be cut to length Acrylic fibre optics for OBF / OOF housings, diffuse reflection system, can be cut to length Acrylic fibres on a reel for OBF housing Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com
Page
95 95 95 95 96 96 96 96 96 97 97 98
www.ifm.com
93
Acrylic and glass fibre optic sensing heads and amplifiers. Can be used in areas where space and access is restricted. Fibres for high temperatures and use with aggressive chemicals. Multi-channel amplifiers with display and logic functions. Simplified wiring and reduced space requirement.
Photoelectric sensors: fibre optics Fully automatic manufacturing machines become more and more compact. Fibre optics are used where mounting space for photoelectric standard sensors is confined. Advantages of these systems: The evaluation electronics and the optoelectronic components are located separately from the sensing surface of the system. Fibre optic sensing heads can therefore be mounted in places where access is difficult. Fibre optics are the best choice, in particular for short ranges. Versions of fibre optic systems Through-beam principle Transmitting and receiving fibre optics are laid separately. The two ends (fibre optic heads) are mounted opposite each other. The light beam interruption is evaluated according to the through-beam principle. The maximum range is 120 cm. Diffuse reflection principle Transmitting and receiving fibres are in one sheath. The sensing head incorporates receiving and transmitting fibre bundles. The ranges of the ifm sensors are max. 70 mm. Applications of fibre optic systems: Confined space The fibre optic head is directly located where sensing takes place, the mating amplifier where sufficient mounting space is available. Detection of minute objects Depending on the type of sensing head and range objects up to 0.5 mm can be detected safely. When the movement of objects is precise, it is possible to detect fine structures, e.g. thread pitches. High temperatures Fibre optics with metal sheath can be used up to 290 C, fibre optics with metal silicone sheath up to 150 C. Chemical resistance Metal silicone sheathed fibre optics are resistant to many aggressive chemicals.
Fibre optic systems can also be mounted in places where access is difficult. Minute objects up to 0.5 mm are detected safely.
www.ifm.com
94
[V]
[V]
Acrylic fibre optics for OBF / OOF housings, diffuse reflection system
Type Fibre optic material Range OB50.. / OBF5.. / OO50.. [mm] PMMA 20 / 25 / 60 aluminium Sensing head material Ambient temperature [C] -40...70 PE (polyethylene) 7 E20639 Sheathing material Drawing no. Order no.
www.ifm.com
95
Acrylic fibre optics for OBF / OOF housings, through-beam system, can be cut to length
Type Fibre optic material Range OB50.. / OBF5.. / OO50.. [mm] PMMA 45 / 80 / 120 aluminium Sensing head material Ambient temperature [C] -40...70 8 E20768 Sheathing material Drawing no. Order no.
PMMA
aluminium
-40...70
E20767
Acrylic fibre optics for OBF / OOF housings, diffuse reflection system, can be cut to length
Type Fibre optic material Range OB50.. / OBF5.. / OO50.. [mm] PMMA 55 / 110 / 235 aluminium Sensing head material Ambient temperature [C] -40...70 9 E20765 Sheathing material Drawing no. Order no.
acrylic fibres on a reel 20 m for type OBF Housing materials: PE / Fibre: : PMMA
E20773
acrylic fibres on a reel 50 m for type OBF Housing materials: PE / Fibre: : PMMA
E20774
Accessories
Type Description Order no.
E20600
Wiring diagrams
1
1 4 2
L+
4: Out 1 2: Out 2
7 3
7: function check
www.ifm.com
96
Wiring diagrams
2
1 4
4: Out 1 2: Out 2 5: Out 3 6: Out 4
4
L+ A E L+
E: Out 1 P: Out 2 S: Out 3 G: Out 4 C: Out 5 T: Out 6 N: Out 7 J: Out 8
6 7 3 L
J O L L
7: function check 3
A E L+
E: Out 1 P: Out 2 S: Out 3 G: Out 4 C: Out 5 T: Out 6
O: function check 5
1 4 2 3
L+
1 2 4
L+
T O L L
O: function check
www.ifm.com
97
M12 x1
36
1 44 60 LED
3,2
15
23
www.ifm.com
98
M8
M4
16
99
100
Selection chart
Sensors for the detection of transparent objects Sensors for distance and level measurement Sensors for colour detection Safety light grids Accessories Evaluation units light curtains / safety light grids Scale drawings - CAD download: www.ifm.com Wiring diagrams
Page
103 103 103 - 104 104 104 104 105 105
www.ifm.com
101
High-quality photoelectric sensors for different applications. Excellent price / performance ratio. Extremely compact laser distance sensor with 10 m range. Sensor for the detection of transparent objects (PET, glass, film etc.). Extensive range of system components for easy and safe mounting.
Detection of transparent objects Counting bottles and glasses or the reliable monitoring of film for tear can be performed without problem using specially designed retro-reflective sensors. ifm offers a retro-reflective sensor with a small switching hysteresis, in particular for the detection of transparent objects. Due to the operating principle, retro-reflective sensors have the advantage that the light beam must pass the object to be detected twice. Thus the light is sufficiently weakened to detect a transparent object safely. Precise adjustment is made by means of the Teach button. Distance measurement The continued development of the pmd technology (Photonic Mixer Device) now enables distance measurement to within a millimetre at high ranges using a laser sensor. The efector pmd laser sensor operates to the time-of-flight principle: A light beam is emitted by a transmitting element and reflected to the receiver element by an object. The measured time of flight relates to the distance from the sensor to the object. Traditional time-of-flight sensors use a photodiode as receiver element. Additional electronics is used for signal acquisition and processing. Disadvantage: This sensor design is complex, large in size and therefore often not suitable for industrial position sensing. In comparison, the efector pmd sensors receiver element is a System-on-Chip design: both sensor element and electronics for signal evaluation are integrated on a single silicon chip called a Photonic Mixer Device (PMD). The advantage: The sensor offers a high performance in a compact, industrially compatible housing. efector pmd can be used for level measurement and positioning tasks, for example to position industrial trucks in high bay storage areas and to protect autonomous industrial transport systems against collision.
The efector pmd provides an analogue signal that is proportional to the objectto-sensor distance.
www.ifm.com
102
[V]
[V]
M12 connector Output function OUT1: normally open / closed programmable OUT2: normally open / closed programmable or analogue (4...20 mA / 0...10 V, scalable) DC PNP Wiring diagram no. 7
Optical distance sensor 0.2...10 m 6 18...30 150 1...50 3 O1D100
M12 connector Output function OUT1: normally open / closed programmable OUT2: normally open / closed programmable or analogue (4...20 mA / 0...10 V, scalable) DC NPN Wiring diagram no. 8
Optical distance sensor 0.2...10 m 6 18...30 150 1...50 3 O1D103
M12 connector Output function OUT1: normally open / closed programmable OUT2: normally open / closed programmable or analogue (4...20 mA / 0...10 V, scalable) DC PNP Wiring diagram no. 7
Optical distance sensor Optical distance sensor Optical level sensor Optical distance sensor 0.3...6 m 0.2...10 m 0.2...10 m 1...75 m 6 6 6 150 18...30 18...30 18...30 18...30 150 150 150 150 1...33 1...33 1...33 1...33 3 3 3 3 O1D155 O1D105 O1D300 O1D106
[V]
M12 connector Output function light-on / dark-on programmable DC PNP/NPN Wiring diagram no. 2
Colour sensor 17 mm 2.5 x 6 10...36 50 2000 4 O5C500
www.ifm.com
103
Type
Operating principle
Measuring range
Ub
Drawing no.
Order no.
[V]
[V]
Accessories
Type Description Order no.
Angle bracket for type O5 Housing materials: stainless steel 316Ti / 1.4571
E21087
Prismatic reflector 50 x 50 mm angular for laser sensors and glass / film detection sensors Housing materials: plastics
E20722
Mounting set Clamp mounting rod mounting 12 mm for type O1D, O2D Housing materials: fixture: stainless steel / clamp: stainless steel / screws: stainless steel / Nut: high-grade stainless steel
E2D101
Safety relay Muting relay Housing for DIN rail mounting For the connection of safety light curtains / safety light grids with OSSD Safety category type 4 to IEC 61496 for industrial applications
G2001S
www.ifm.com
104
Wiring diagrams
1
1
L+
3
1 2
5
L+
4
2
L+
5
1
5 3 Out 1 Out 2 Out 3
L
1 2 3 4 5 6 7 8
OSSD1
L+
OSSD2 K1/K2/Restart SEL_A SEL_B
2
4
2: Teach
Out
4 6 7
2
1 2
5
L+
AT N.C. Out
L+
L+
1 2 4
L+
1 4 2
L+
4: Out 1 2: Out 2
4: Out 1 2: Out 2
1 2 4 2: Out 2 4: Out 1 3
L+
1 2 4
L+
2: Out 2 4: Out 1
2
46,8 6,4 6 19,5 1 LED 6 5x9
24
LED 5
LED 11 8,2
18,2
25
37
1,8 5,3 19
36,5 43,5
3,5 8,5
M8x1 M12 x1
9 4
11,6
LED
1: pushbutton
1: Programming buttons, 2: When a M5 mounting screw is used, the max. tightening torque is 2 Nm.
www.ifm.com
56 70,3
35
25
105
6
119 M5 28 96 80 43
45
45 59
30
M12 x1
M12x1 20 25
1 M12 x1
M5
52
21 30
28 39
14
4 3
LED
18,2
25,9 38
25
25
56 70,3
1: fibre optic connection, 2: selection switch color tolerance, 3: programming selector switch, 4: teach button 7
14,5 M5 1,5
1: Programming buttons, 2: When a M5 mounting screw is used, the max. tightening torque is 2 Nm. 5
96 M5 28 80 43
40 20
40
53
102 29,5 10 40 20 M12x1 28 10,5 10 30 28 28 114,5 99 3 5,5
M12 x1
1 M12 x1
M5
21 30
40
53
T: Transmitter, R: Receiver, 1: LED 3 colours (red/green/orange), 2: LED yellow, 3: LED 2 colours (red/green) 8
15
28
39
69
35
LED
4 3
LED
1: lens, 2: selection switch color tolerance, 3: programming selector switch, 4: teach button
www.ifm.com
106
69
107
108
Object recognition
Selection chart
Sensors for object recognition with PNP output function Accessories 2D Sensors for 3D object recognition Accessories 3D Scale drawings - CAD download: www.ifm.com
Page
111 111 111 112 112
www.ifm.com
109
Object recognition
2D vision sensor for object recognition. 3D sensor for assessment of distance, level or volume. 3D camera for spatial detection of scenes and objects. Easy, time-saving parameter setting. Robust, industrially compatible housing with integrated lighting.
2D vision sensor for object recognition In automation technology visions sensors are an integral part of assembly and manufacturing tasks as well as quality control and thus increase efficiency. They are cameras with application-specific evaluation, i.e. reliable electronic eyes at a low cost and a high degree of integration. In a robust, industrially compatible housing they combine lighting, lens, camera chip, evaluation and process connections for the integration in the higher-level controller. The application possibilities of efector dualis range from presence, position and orientation monitoring, via sorting and counting tasks to quality control. 3D sensor for assessment of distance, level or volume efector pmd 3d is the first industrial 3D sensor that can assess objects in three dimensions at a glance. Special feature: the time-of-flight measurement and evaluation are integrated on one chip. Each pixel of this chip matrix evaluates its distance to the object. The image of the object on the chip matrix and the respective distance values correspond to a 3D image. This technology enables the detailed assessment of the objects or scenes conditions by means of volume, distance or level detection in three dimensions. Typical applications are completeness checks and level monitoring in the food industry as well as presence and dimension monitoring in conveying. 3D camera for detection in three dimensions of scenes and objects The pmd 3d camera detects scenes and objects in their spatial dimensions at a glance. In contrast to laser scanners it does not require moving components and is thus robust and wear-free. The operating principle is the same as for the 3D sensor. Besides the 3D distance image the camera provides a grey image of the scene. The combination of these images offers integrators the possibility to freely program application-specific tasks by means of a software development kit. This results in lowcost application solutions in the areas of packaging, storage and materials handling, airport logistics, collision avoidance, robotics, monitoring of space and persons.
Set-up in just a few steps: The professional and easy menu guidance allows configuration of the efector dualis to your application in just six operating steps.
www.ifm.com
110
Object recognition
Accessories 2D
Type Description Order no.
E2D200
Mounting set O2D, O2M, O2I Clamp mounting rod mounting 12 mm Housing materials: fixture: stainless steel / clamp: stainless steel
E2D110
mounting rod 14 / M12 Length: 130 mm straight Housing materials: stainless steel 316Ti / 1.4571
E20939
mounting rod 14 / M12 Length: 200 mm angled Housing materials: stainless steel 316Ti / 1.4571
E20941
E20952
Plastic protective pane for the food industry O2D / O2I Housing materials: housing: diecast zinc black / lens: PMMA
E21166
E30112
Socket ifm electronic angled Free from silicone Free from halogen gold-plated contacts M12 connector 5 m Housing materials: PUR
E11232
[V]
www.ifm.com
111
Object recognition
Accessories 3D
Type Description Order no.
E3D200
Mounting set O3D Clamp mounting rod mounting 14 mm Housing materials: fixture: stainless steel / clamp: stainless steel
E3D103
mounting rod 14 / M12 Length: 130 mm straight Housing materials: stainless steel 316Ti / 1.4571
E20939
75
95
21,5
20,5
57 60
45
24,5
80
4,3
63,8
19
45
9,5 7
19,7 33 44
16
M12x1 M12x1
18
40 60,5
M12x1 M12x1
www.ifm.com
112
94
Object recognition
113
114
Encoders
Selection chart
Incremental encoders with solid shaft Incremental encoders with hollow shaft Absolute multiturn encoders (Profibus) Absolute singleturn - encoders (CANopen) Absolute multiturn - encoders (CANopen) Accessories Scale drawings - CAD download: www.ifm.com
Page
117 117 117 117 118 118 118 - 119
www.ifm.com
115
Encoders
Robust designs. Industrial standard housings. Cable entry for axial and radial use. Designs with integrated bus interface. Hollow shaft encoder for direct mounting on actuators.
Encoders In many manufacturing and production processes they are indispensable as reliable transducers to ensure precise positioning. They convert rotary movement into digital signals. Linear measurement is also possible in conjunction with rack and pinion or measuring wheels. Encoders use the wear-free photoelectric detection. A pulse disc firmly attached to the shaft ensures this detection. Encoders are basically divided into two types: incremental and absolute encoders. Incremental encoders Incremental encoders generate a precisely defined number of pulses per revolution. They are a measure of the angular or linear distance moved. The coded disc is divided into separate segments which are alternately transparent or opaque. An LED emits a parallel-orientated light beam which illuminates all segments of the coded disc. Photo elements receive the modulated light and convert it into two sinusoidal signals. Digitalisation electronics amplify the signals and shape them into square-wave pulse trains which are generated via the line driver in the output. The phase difference between signal A and B, which are phase-shifted by 90 degrees, allows evaluation of the direction of rotation. Absolute encoders Absolute encoders provide an absolute numerical value for each angular position. This code value is available immediately after power is applied. This absolute value makes a reference procedure like the one required for the incremental encoder unnecessary. Absolute encoders are used wherever angular positions have to be allocated to a certain value and where the detection of the present position is absolutely necessary in the case of a power failure. Singleturn and multiturn Singleturn encoders divide a mechanical revolution (0 to 360 degrees) into a certain number of measuring steps. The measuring values are repeated after one revolution. The maximum resolution is 8192. Multiturn encoders, however, do not only detect angular positions but also distinguish between multiple revolutions.
Hollow shaft encoder for direct mounting on the axis.
Linear measurement by means of a counter: rotary movement is converted into digital signals.
www.ifm.com
116
Encoders
13 bits
9...36
10
-40...70
RN7004
www.ifm.com
117
Encoders
25 bits
9...36
10
-40...70
RM7004
Accessories
Type Description Order no.
Angle bracket for encoders for type RB, RC, RU, RN, RM Housing materials: aluminium black anodised
E60033
Angle bracket for encoders for type RM, RMU, RN, RU Housing materials: aluminium black anodised
E60034
E60064
Flexible coupling with adjusting screw connection [SV] 6 mm / 6 mm Housing materials: aluminium
E60063
Flexible coupling with adjusting screw connection [SV] 6 mm / 10 mm Housing materials: aluminium
E60028
2
1
30
37,5
15 2 6
2 42
46,70,5
10 4
18 35
6
6
12 0
3 3
www.ifm.com
118
50 h7 58
4,5
Encoders
5
1 42 80 12 H7
120
20
3,2
10,5 4
63 68
28 58
6 24
24
TX 8
20
3 3 18
4
1 48 70
120
1: M4 5 mm deep
10 20
10
20
24
18
1: M4 5 mm deep
www.ifm.com
36 f8 58
50 h7 58
119
120
Evaluation systems
Selection chart
Universal speed monitors Speed monitor with integrated sensor Multifunctional displays for digital signals / frequency input Universal counters Multifunctional displays for analogue standard signals Accessories Scale drawings - CAD download: www.ifm.com Wiring diagrams
Page
123 123 123 123 124 124 124 124
www.ifm.com
121
Evaluation systems
Easy adjustment and parameter setting. Clear LCD display with simple pushbutton setup. Primary voltage 24V dc or 110 / 230V ac. Switching relays and transistor outputs. Analogue also available. Standstill, overspeed, direction, slip and frequency conversion.
Evaluation systems Although PLC applications in industrial automation are becoming more and more versatile there are still numerous processes in practice which require decentralised monitoring. For this ifm electronic offers a number of pulse evaluation systems in the product group ecomat 200. The application area ranges from simple standstill monitoring or blockage protection of a conveyor belt, maximum speed monitoring in wind power stations, slip monitoring of couplings through to direction monitoring, e.g. twin pumps with non-return valves. Different units for rail mounting and compact designs in M18 and M30 metal housings are available. They include microprocessor-controlled units for pane mounting to display analogue signals, RPM, speeds, processing times, quantities and electronic preset counters for the detection of quantities or linear measurement as well as electronic timer relays. All units are distinguished by a high reliability and easy handling. Independent of the PLC they indicate operating states or signal faults. This helps to reduce downtimes and production loss. ifm electronic offers the following evaluation systems: Speed monitor Standstill monitor Slip- / synchronisation monitor Direction monitor Frequency-to-current converter Threshold relay Displays with frequency and analogue input Counters Switching amplifiers
Machine cycles must also be monitored in conveying. Pulse evaluation systems are used for decentralised monitoring of drives.
www.ifm.com
122
Evaluation systems
DI0001* DI5001
10 f
DC PNP
10...36 DC
3...300
15
DI5009
12 nf
DC PNP
10...36 DC
3...6000
0...15
DI6001
f = flush / nf = non flush * Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Multifunctional displays for digital signals / frequency input
Type Ub [V] Inputs Input function Setting range [puls. / min.] Setting range [Hz] Outputs analog Outputs relays Outputs transist. Drawing no. Order no.
Universal counters
Type Ub [V] Inputs Input function Setting range [puls. / min.] Setting range [Hz] Outputs analog Outputs relays Outputs transist. Drawing no. Order no.
www.ifm.com
123
Evaluation systems
Accessories
Type Description Order no.
E10736
E10737
Wiring diagrams
1 2 3 4
1 L+
BN
L1 L+ N L
BN BK BU
L+
1 4
L+
2 4
BU
2: pulse output (the pulse sequence corresponds to the damping frequency), 4: switching output (adjustable)
3
120
7A1 8A2
13 19
14 20
15 21
16 22
17 23
18 24
35,5
78
M30 x1,5
2 LED
36
www.ifm.com
124
Evaluation systems
6
48 105 86,5 3
48
129
7
75 50 4
45
39
www.ifm.com
33
125
126
Level sensors
Selection chart
Sensors for oils and coolants, LK12xx: approval to the German overspill standard WHG, section 19 Variable level sensors for water-based media (dielectric constant > 20) Sensors for hydrostatic level monitoring Sensors for hydrostatic level monitoring in hygienic and wet areas Sensors for oils and coolants, LI20xx: approval to the German overspill standard WHG, section 19 Accessories for level sensors LK, LR, LT, LL, LI Accessories for level sensors PA, PG, PI, PN, PS, PY Scale drawings - CAD download: www.ifm.com Wiring diagrams
Page
129 129 129 - 130 130 131 131 132 133 133
www.ifm.com
127
Level sensors
Guided wave radar, capacitive and hydrostatic level sensors. No movings parts means high reliability and long life. Outputs for continuous or discrete level measurement. Integrated LED display for local indication of the current level. Units suitable for common industrial and process fluids.
Level sensors In industrial applications where fluids or bulk material are used, storage tanks or silos are used for processing or storing of media. Sensors are used to detect the levels. Even critical process conditions such as emptying a hydraulic tank or the unintentional overspill of a tank are monitored by level sensors. Advantages of electronic sensors Deposits and wear and tear often lead to failures in particular if mechanical switches are in contact with the medium. The electronic ifm sensors however can do without any mechanical components. This makes the sensors especially robust and reliable. Another advantage of electronic sensors is the local indication of the level or the easy setting of the switching threshold simply by pressing a button. Measurement technique For continuous level measurement the level is detected continuously, converted into an electrical signal and indicated. Depending on the type the units have freely programmable switching outputs or an analogue output for further processing. Continuous level sensors from ifm electronic use three different physical measuring principles: For capacitive measurement the probe and the tank form an electrical capacitor. The capacity changes with the level and is converted into a level measurement by a microprocessor. For hydrostatic level measurement a measuring cell detects the hydrostatic pressure of the material. Here the pressure change is a measure for the level. The efector gwr level sensor operates on the principle of guided wave radar. Electromagnetic pulses are transmitted by the sensor head and guided along the probe. If the microwave pulse hits the medium to be detected, it is reflected and the time of flight is evaluated by the sensor.
For special applications: Capacitive probe for monitoring oils and coolants. Measurement in the medium: Probe sensors will directly immersed in the medium to be monitored.
www.ifm.com
128
Level sensors
Sensors for oils and coolants, LK12xx: approval to the German overspill standard WHG, section 19
Type Probe length [mm] Active zone [mm] Inactive zone [mm] Ub [V] Medium temperature [C] Iload [mA] Wiring diagram no. Drawing no. Order no.
M12 connector (according to EN 61076-2-101) Output function 1 x analogue 4...20 mA / 0...10 V (OUT2); 1 x normally open / closed programmable (OUT-OP) DC PNP
264 472 728 195 390 585 53 / 15 53 / 30 102 / 40 18...30 18...30 18...30 200 200 200 1 1 1 1 1 1 LK3122 LK3123 LK3124
M12 connector (according to EN 61076-2-101) Output function 2 x normally open / closed programmable DC PNP
264 472 728 195 390 585 53 / 15 53 / 30 102 / 40 18...30 18...30 18...30 200 200 200 2 2 2 1 1 1 LK1022 LK1023 LK1024
M12 connector (according to EN 61076-2-101) Output function 3 x normally open / closed programmable (OUT1...OUT3); 1 x normally open / closed programmabl (OUT-OP) DC PNP
264 472 728 195 390 585 53 / 15 53 / 30 102 / 40 18...30 18...30 18...30 200 200 200 3 3 3 1 1 1 LK8122 LK8123 LK8124
Variable level sensors for water-based media (dielectric constant > 20)
Type Probe length [mm] Active zone [mm] Inactive zone [mm] Ub [V] Medium temperature [C] Iload [mA] Wiring diagram no. Drawing no. Order no.
M12 connector (according to EN 61076-2-101) Output function normally open / closed programmable; 4...20 mA or 0...10 V DC PNP
150...1600 L - 50 40/10 18...30 0...80 200 4 2 LR3000
M12 connector (according to EN 61076-2-101) Output function 2 x normally open / closed programmable DC PNP
150...1600 L - 50 40/10 18...30 0...80 200 2 2 LR7000
M12 connector (according to EN 61076-2-101) Output function 4 x normally open / closed programmable DC PNP
150...1600 L - 50 40/10 18...30 0...80 200 5 3 LR8000
M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) DC PNP/NPN
G I Display unit -0.25...0.25 10 30 18...32 9 4 PY2068
M12 connector Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V; scaleable 1:4) DC PNP/NPN
G I Display unit -0.5...0.5 10 30 20...30 10 5 PN2069
www.ifm.com
129
Level sensors
Type
Process connection
Display LED
Ub DC [V]
Drawing no.
Order no.
M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) DC PNP/NPN
Aseptoflex Aseptoflex Aseptoflex Display unit Display unit Display unit -1...1 -0.0124...0.25 -0.05...1 10 10 10 30 30 30 18...32 18...32 18...32 9 9 9 8 8 8 PI2099 PI2098 PI2097
M12 connector Output function 1 x normally open / normally closed programmable + 1 x normally open / normally closed programmable or 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP/NPN
Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Display unit Display unit Display unit Display unit Display unit -0.005...0.1 -0.0124...0.25 -1...1 -0.05...1 -0.124...2.5 4 10 10 10 20 30 30 30 30 50 18...32 18...32 18...32 18...32 18...32 10 10 10 10 10 9 9 9 9 9 PI2789 PI2798 PI2799 PI2797 PI2796
M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP/NPN
Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Display unit Display unit Display unit Display unit Display unit -0.005...0.1 -0.0124...0.25 -1...1 -0.05...1 -0.124...2.5 4 10 10 10 20 30 30 30 30 50 18...32 18...32 18...32 18...32 18...32 9 9 9 9 9 10 10 10 10 10 PG2789 PG2798 PG2799 PG2797 PG2796
www.ifm.com
130
Level sensors
Sensors for oils and coolants, LI20xx: approval to the German overspill standard WHG, section 19
Type Probe length [mm] Output Ub [V] Medium temperature [C] Iload [mA] Wiring diagram no. Drawing no. Order no.
DC PNP
10...36 10...36 10...36 10...36 200 200 200 200 8 8 8 8 11 11 11 11 LI5141 LI5142 LI5143 LI5144
normally open / closed programmable normally open / closed programmable normally open / closed programmable normally open / closed programmable
Flange plate 73-90 / G for level sensors LR according to DIN 24557 Housing materials: flange: stainless steel / sealing: NBR
E43201
Flange plate 65-80 / G for level sensors LR Housing materials: flange: stainless steel
E43202
Probe Probe length: 240 mm for level sensors LR Housing materials: stainless steel
E43203
Probe Probe length: 450 mm for level sensors LR Housing materials: stainless steel
E43204
Probe Probe length: 700 mm for level sensors LR Housing materials: stainless steel
E43205
Probe Probe length: 1000 mm for level sensors LR Housing materials: stainless steel
E43207
Probe Probe length: 1200 mm for level sensors LR Housing materials: stainless steel
E43208
Probe Probe length: 1400 mm for level sensors LR Housing materials: stainless steel
E43209
E43910
www.ifm.com
131
Level sensors
Protective cover for fluid sensors with connector M12 Housing materials: polyurethane
E30006
Protective cover for fluid sensors stainless steel with transparent Teflon window Housing materials: stainless steel 316Ti / 1.4571 / PFA / EPDM / ventilation strip: Teflon film 0.32 mm / O-ring: EPDM
E30104
E30007
Cable clamp fastener for submersible pressure transmitter PS3 Housing materials: steel / plastics
E30399
Filter element for submersible pressure transmitter PS3 for fixing on the capillary tube
E30400
Splitter box with ventilation and terminal block for submersible pressure transmitter PS3 Housing materials: plastics
E30401
Additional weight for submersible pressure transmitter PS3 Housing materials: stainless steel 316Ti / 1.4571
E30402
Welding adapter 50 mm with Aseptoflex thread Housing materials: stainless steel 316L / 1.4404 / O-ring: FPM FDA compliant
E30052
Aseptoflex adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex adapter Housing materials: stainless steel 316L / 1.4404
E33001
Welding adapter 50 mm for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E30122
Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33201
Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33701
www.ifm.com
132
Level sensors
Wiring diagrams
1
1 BN 2 WH 4 BK
3
1 2 L+ 3 4 5 L 6 7 L+ Out 2 L Out 1 Out 3 Out-OP / Out 4 n.c.
5
1
7
2
4 5 6
L+
Out 2 Out 1 Out 3 Out 4 n.c.
L+
2: Out 2 3 BU 4: Out-OP
7
3
2
1
L+
4
1 2 4
4 2
2: Out 2 4: Out 1 2: OUT2 4: OUT1
L+
BN WH GY
L+ L
1 4 3
L+
11
1
1 L+
1 2 4
3
L+
1 4
2
L+
2
1 2 4 L 3 L+ L P L
10
1
2
1
2
L+
4
2: Out 2 4: Out 1
4
L
2: Out 2 4: Out 1 3
L+
L+
2
4
2: Out 2 4: Out 1 2: Out 2 4: Out 1
4 2
L
50
64
I1
16
1: 4-digit alphanumeric display, 2: LEDs, 3: Programming buttons, 4: Housing connection (flat-pin connector 6.3 mm following DIN 46244)
www.ifm.com
I2
M12 x1
57
30,5
133
Level sensors
5
2 34
30
3 47
57
87
1 91,5
M12 x1 30 G 1/4
100
76
M12 x1
32
1,3
21,5 27
I1
G3 4
I2
1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button 6
1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming buttons 3
2 50 3 63
57 76
M12 x1
30
7
30 M12 x1
87
32
I1
1,3
30
I2
G1 4 21,5 27
1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming buttons 4
2 34 3 48
8
2 3 47
48 34
14
G3 4
75
27
14 119 M12 x1
1 91,5
M12 x1
57,3
1,3
14
36 14,5
21,5 27
30
G 1/4 36 4 5
1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button
1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: Aseptoflex sealing edge, 5: Aseptoflex thread
www.ifm.com
134
85
57,3
Level sensors
10
100 57
105,8
M12 x1
16,8
52,8
34
G1
24
G1
16,6
16,8
60,5
153
M12 x1
A
LED
1
1: Programming buttons
www.ifm.com
135
136
Flow sensors
Selection chart
Magnetic-inductive flow sensors with integrated temperature measurement (sealing material EPDM) Magnetic-inductive flow sensors (sealing material FKM) Compact housings for adapters for flow monitoring Compact designs for adapter with flow and temperature monitoring Compact housings for adapters for hygienic and wet areas Flow sensors for connection to control monitors, industrial applications Flow sensors for connection to control monitors, industrial applications, titanium housing Control monitors for industrial applications Flow sensors for connection to control monitors with ATEX approval Control monitors with ATEX approval Air flow monitors Compressed air meters Compressed air meter for special gases Inline sensor for small dosing quantities of water and aqueous solutions Ultrasonic flow rate sensors for liquids (water, glycol solutions, oils) Accessories for flow sensors and control monitors Flange adapters for flow sensors Accessories for volumetric flow sensors Grounding clamps for magnetic-inductive volumetric flow sensors Wiring diagrams Scale drawings - CAD download: www.ifm.com
Page
139 139 139 140 140 140 140 141 141 142 142 142 143 143 143 143 - 144 144 - 145 145 145 145 - 146 146 - 150
www.ifm.com
137
Flow sensors
For liquids and gases. Special versions for food applications and hazardous areas. Optional fittings for variable process connection. Flow monitoring also for aggressive media.
Flow sensors In almost all fields of process and plant engineering liquids or gases are used for coolant and lubricant supply of machines and units, ventilation of installations and buildings and the processing of products. In case of no flow of these media considerable damage and downtime may result. Thus it is very important to monitor that these media are at the right place at the right time and in sufficient quantities. In modern installations electronic flow monitors are used for this purpose. They work without wear and tear and without mechanical components. This guarantees reliable monitoring even in case of difficult media over a long period. Operating principle Electronic flow sensors from ifm electronic operate with different measurement techniques. They meet all requirements from a simple monitoring function to the exact detection of flow quantities. Harmonised operating menus ensure that operators who use different flow sensors can quickly and precisely carry out settings on the sensors. Some flow sensors feature an integrated temperature monitor which makes an additional measuring point unnecessary. This enables to control processes in the optimum operating status especially with regard to energy savings. Analogue, binary and pulse outputs offer various possibilities to process the measured data. Due to the flexible programming by means of pushbuttons the flow sensors can be adapted to different conditions. The sensors are mounted via adapters.
Optimised consumption of compressed air. Monitoring very small flow rates: Flow monitor with flow adapter.
www.ifm.com
138
Flow sensors
Magnetic-inductive flow sensors with integrated temperature measurement (sealing material EPDM)
Type Process connection Measuring range [l/min] Medium temperature [C] Pressure rating [bar] Response time [s] Ub Wiring diagram no. Drawing no. Order no.
[V]
M12 connector Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programmG 0.25...25.00 -10...70 16 < 0.150 19...30 1 1 SM6100
0.5...50.0
-10...70
16
< 0.150
19...30
SM7100
G1
0.7...100.0
-10...70
16
< 0.150
19...30
SM8100
[V]
* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 5 A (fast acting). Recommendation: check the unit for reliable function after a short circuit.
www.ifm.com
139
Flow sensors
3...300 / 200...3000
3...100 / 200...800
-25...95
30
1...10
19...36
SI6700
3...300 / 200...3000
3...100 / 200...800
-25...95
30
1...10
19...36
10
SI6800
3...300 / 200...3000
3...60 / 200...800
-25...80
1...10
300
300
12
SF5200
Flow sensors for connection to control monitors, industrial applications, titanium housing
Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Response time [s] Max. T0 gradient [K/min] Pressure rating [bar] Drawing no. Order no.
www.ifm.com
140
Flow sensors
* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, Note: miniature fuse to IEC60127-2 sheet 1,. Recommendation: check the unit for reliable function after a short circuit. Flow sensors for connection to control monitors with ATEX approval
Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Response time [s] Max. T0 gradient [K/min] Pressure rating [bar] Drawing no. Order no.
3...300 / 200...2000
3...60 / 200...800
-20...70
1...10
15
30
19
SF321A
www.ifm.com
141
Flow sensors
15 terminals...2.5 mm
230 AC / 10 110 AC / 10 24 DC / 10 125 5 5 30 30 30 relay energised relay energised relay energised relay de-energised relay de-energised relay de-energised 21 21 21 SN2301* SN2302* SR2301*
* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, Wire break monitoring. Recommendation: check the unit for reliable function after a short circuit. Air flow monitors
Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Response time [s] Ub / tolerance [V] / [%] Drawing no. Order no.
* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 5 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Compressed air meters
Type Setting range Medium temperature [C] Pressure rating [bar] Response time [s] Ub Wiring diagram no. Drawing no. Order no.
[Nm3/h]
[V]
M12 connector Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programmable or analogue (4...20 mA scaleable) DC PNP
0.14...15.00 0...60 16 < 0.1 19...30 15 23 SD5000
0.7...75.0
0...60
16
< 0.1
19...30
15
24
SD6000
2.0...225.0
0...60
16
< 0.1
19...30
15
25
SD8000
3.5...410.0
0...60
16
< 0.1
19...30
15
26
SD9000
6...700
0...60
16
< 0.1
19...30
15
27
SD2000
www.ifm.com
142
Flow sensors
[Nm3/h]
[V]
M12 connector Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programmable or analogue (4...20 mA scaleable) DC PNP
Ar: 0.8...118.2 / CO2: 0.5...71.7 / N2: 0.5...73.0 Nm/h 0...60 16 < 0.1 19...30 15 24 SD6100
Inline sensor for small dosing quantities of water and aqueous solutions
Type Process connection Measuring range [ml/min] Display range [ml/min] Pressure rating [bar] Medium temp. [C] Drawing no. Order no.
Ultrasonic flow rate sensors for liquids (water, glycol solutions, oils)
Type Process connection Measuring range [l/min] Medium temperature [C] Pressure rating [bar] Response time [s] Ub Wiring diagram no. Drawing no. Order no.
[V]
M12 connector Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programmable or analogue (4...20 mA / 0...10 V, scaleable) DC PNP/NPN
G 0.1...50.0 -10...80 16 < 0.250 19...30 1 29 SU7000
G1
0.2...100.0
-10...80
16
< 0.250
19...30
30
SU8000
G1
0.4...200.0
-10...80
16
< 0.250
19...30
31
SU9000
Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: titanium
E40114
Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: titanium
E40115
Adapter M18 x 1.5 - M12 x 1 Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: titanium
E40128
www.ifm.com
143
Flow sensors
Type
Description
Order no.
Adapter M18 x 1.5 - M12 x 1 Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: stainless steel 316L / 1.4404
E40101
Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: stainless steel 316L / 1.4404
E40099
Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: stainless steel 316L / 1.4404
E40096
Welding adapter M18 x 1.5 - 23 mm Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: PE-100
E40138
Welding adapter M18 x 1.5 - 24 mm Insertion depth of the probe of SID, SFD, TN: 15 mm Housing materials: stainless steel 316L / 1.4404
E40124
Flow adapter (for low flow rates) M12 x 1 - G 1/8 for flow sensors and compact flow monitors with adapter Housing materials: stainless steel 316L / 1.4404
E40129
Flow adapter (for low flow rates) G - G 1/8 for flow sensors and compact flow monitors Housing materials: PVDF
E40057
Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33201
Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33202
Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33701
Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33702
Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33222
Aseptoflex Vario adapter Varivent type F DN25 (1), D = 50 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33721
www.ifm.com
144
Flow sensors
Type
Description
Order no.
Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33722
Welding adapter 50 mm for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E30122
Adapter G - R for flow monitor type SM6 flat seal Housing materials: stainless steel 316Ti / 1.4571 Pack quantity: 2
E40199
Adapter G - G for flow monitor type SM6 flat seal Housing materials: high-grade stainless steel
E40189
Grounding clamp G for flow monitor type SM6 Housing materials: stainless steel
E40196
Wiring diagrams
1
1 2 4 3 BN WH BK BU L+ OUT2/InD OUT1 L
4
1 L1
7
2 WH
3 BU
10
1 BN 4 BK 5 GY 2 WH 3 BU
1 2 3 VS2000 Exi 7 8 9
2
3
n.c.
Out
1 BN
4 5
4 BK 5 GY
2
1 4 2 3
L+ n.c.
5
1 4 3 L 2 L P L+
8
WH
BU
BN
BK
11
BN
BK
L1 L+
WH
BU
GY
N L
9
BN BK GY 1 2 3 VS2000 Exi 7 8 9
12
BN
BK
L+
1 4 3
L+
4
L
L+
WH BU
WH
BU
2
3
S2 S1
www.ifm.com
145
Flow sensors
Wiring diagrams
13
AC L N
1 2 4 5 6 7 17 18 19 20 21 22 23 24
14
L+ DC L WH BU BN BK GY 4 5 2 3 1 4 5 2
1 2 4 5 6 7 8 9 10 17 18 19 20 21 22 23 24
WH BU BN BK GY 4 5
2 3 1 4 5
8 9 10
11 12
11 12
1: Flow monitoring, 2: Wire break monitoring, 3: Temperature monitoring, 4: Power-on delay time, 5: Selection liquid / gas
1: Flow monitoring, 2: Wire break monitoring, 3: Temperature monitoring, 4: Power-on delay time, 5: Selection liquid / gas 15
1 2 4
L+
1 2 4
L+
4: Out 1 2: Out 2
4: Out 1 2: Out 2
4
110 73 54
G1 2
G1 2
G1 2
16
16
M12 x1
M12 x1
M12 x1
G1 2
M12 x1
2
110 73 54
5
1 50 2 63
G3 4
G 34
M12 x1
M12 x1
22
14
3
110 73 54
7,7
19
M12 x1
M12 x1
www.ifm.com
146
45
60 65
113
19
M12 x1
27
Flow sensors
20UNF 2A 27
14
113
1 2"
45
60 65
22
34
8,2
15
7,7 10,8
27
M12 x1
50
38
89
137
63
45
60 65
22
14
8,2
106 34
50
63
M12 x1
27
71
119
15
7,7 10,8
55
34 20
7,7
12
82 72 14 M12 x1 44 8,2
10
154
19
22 1
www.ifm.com
M12 x1
113
27
M12 x1
27
147
Flow sensors
17
57 13
27
8,2 G1 4
12
17 19 22 1
57 13
27
7,7
12
103,5
LEDs
17
19
35,5
100
80 15 45 12
G1 2 7,7
LEDs
1 2
17 18 19 20 21 22 23 24
27
20
75 15 45 12
M12 x1
1 50
2 64
83
M12 x1
48 52
27
27
21
45
120
3 19,7
1 2 8
3 9
1: LED display, 2: setting pushbutton, 3: connection for voltage supply and output signals, 4: connection for flow sensor 16
1 50 2 64
13 19 14 20 15 21 16 17
18
48 52
22
140 133 2 LED pot.
83
3 19,7 4
113 2 LED 32
1: LED display, 2: setting pushbutton, 3: connection for voltage supply and output signals, 4: connection for flow sensor
1 2"
35,5
78
G1 2
7,7
23
www.ifm.com
148
Flow sensors
27
2
1 2
133
3
74,5
M12 x1
54
21,3 1 G /4
G /4 31
R2 51
275 475
60 182,3
20
1: 4-digit alphanumeric display, 2: Programming buttons 1: 4-digit alphanumeric display, 2: Programming buttons, 3: hole for M5 fixing screw 24
45
28
117 111 100 M12 x1
1
45
11 1 100 M12 x1
76,8
21,3 R 16,1
G1 8
48
210 300
56 65
125 4,5
25
114
1
45
88,5
33,7
R1 27,3
375 475
37
10
G34 100
G3 4
M12 x1
11 1 100
45
11 1 100
45
11 1 100
42
M12 x1
120
R11 2
39
www.ifm.com
M12 x1
149
Flow sensors
31
130 96 80,5 26
G11 4
G11 4 100
G1 100
G1
48
installation length with pipe adapter E40152 / E40155: 205 mm, installation length with pipe adapter E40153 / E40156: 215 mm
www.ifm.com
150
M12 x1
M12 x1
Flow sensors
151
152
Pressure sensors
Selection chart
Sensors with switching outputs and analogue outputs and display Sensors with switching outputs and display PK sensors with mechanical setting and switching outputs PT sensors for mobile applications with analogue outputs PA / PPA sensors for industrial applications with analogue outputs / AS-i Sensors for hydrostatic level monitoring PI sensors for hygienic and wet areas, 2-wire with analogue output PI sensors for hygienic and wet areas with switching and analogue output Full-metal sensors for hygienic and wet areas with switching output and analogue output Electronic contact manometers for hygienic and wet areas with switching output and analogue output Sensors for pump monitoring PF sensors for hygienic and wet areas with switching and analogue output PL / PM sensors without display for hygienic and wet areas with analogue output Sensors for hygienic and wet areas with Profibus PA Interface Fixing components for pressure sensors Accessories and software Adapters and accessories for adapters Flange adapters Wiring diagrams Scale drawings - CAD download: www.ifm.com
Page
155 155 155 156 156 156 157 157 157 158 158 158 159 159 159 159 - 160 160 160 - 161 161 - 162 162 - 164
www.ifm.com
153
Pressure sensors
Transmitters or sensors with integrated control monitor. Units with special design for hygienic applications. Measuring principles with overload protection and a good long-term stability. Measuring range from -1600 bar. Variable process connection and sealing technology via adapter.
Pressure sensors ifm offers a wide range of electronic pressure and vacuum sensors to meet the requirements of various industrial applications. The ceramic-capacitive measuring cell, tried and tested a million times, is complemented by a stainless steel measuring cell with thick-film wire strain gauges (series PK, PV, PT) and a piezoresistive measuring technique (for pneumatic applications). All units have robust housings and do not require moving parts such as pistons or springs. The result: the sensors are extremely shock and vibration resistant and operate without any wear or maintenance. The tried and tested ceramic-capacitive measuring principle is corrosion-resistant and long-term stable. In the long run this guarantees continuous accuracy of the measured values. The sensors are resistant to dynamic pressure peaks and guarantee high overload resistance even in the case of extreme pressure peaks that occur for example with fast closing valves. Units with wire strain gauge in thick-film technology on a stainless steel measuring cell are distinguished by their very compact and robust design. They can be used in almost all industrial areas. The welded stainless steel measuring cell without any seals ensures a high degree of safety, in particular for applications with gas pressures of up to 400 bar as well as in air-conditioning and refrigerating technology where aggressive coolants (freons) are used.
The display: The 7-segment display shows the system pressure at a glance.
www.ifm.com
154
Pressure sensors
M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) DC PNP/NPN
G I Display unit -0.25...0.25 10 30 18...32 7 1 PY2068
M12 connector Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V; scaleable 1:4) DC PNP/NPN
G I G I G I G I G I G I G I G I Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit 0...400 0...250 0...100 -1...25 -1...10 -0.125...2.5 -0.05...1 -1...1 600 400 300 100 75 20 10 20 1000 850 650 350 150 50 30 50 20...30 20...30 20...30 20...30 20...30 20...30 20...30 20...30 8 8 8 8 8 8 8 8 2 3 3 3 3 3 3 3 PN2020 PN2021 PN2022 PN2023 PN2024 PN2026 PN2027 PN2009
G I
Display unit
-0.5...0.5
10
30
20...30
PN2069
G I
Display unit
-0.0125...0.25
10
30
20...30
PN2028
M8 connector Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x normally closed (diagnostic function) DC PNP
G 1/8 I G 1/8 I Display unit Display unit -1...1 -1...10 20 20 30 30 18...32 18...32 1 1 4 4 PQ7809 PQ7834
www.ifm.com
155
Pressure sensors
www.ifm.com
156
Pressure sensors
PI sensors for hygienic and wet areas, 2-wire with analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.
PI sensors for hygienic and wet areas with switching and analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.
M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) DC PNP/NPN
Aseptoflex Aseptoflex Aseptoflex Aseptoflex Aseptoflex Aseptoflex Aseptoflex Display unit Display unit Display unit Display unit Display unit Display unit Display unit -1...25 -1...10 -1...4 -0.124...2.5 -0.05...1 -0.0124...0.25 -1...1 100 50 30 20 10 10 10 350 150 100 50 30 30 30 18...32 18...32 18...32 18...32 18...32 18...32 18...32 7 7 7 7 7 7 7 10 10 10 10 10 10 10 PI2093 PI2094 PI2095 PI2096 PI2097 PI2098 PI2099
Full-metal sensors for hygienic and wet areas with switching output and analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.
M12 connector Output function 1 x normally open / normally closed programmable + 1 x normally open / normally closed programmable or 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP/NPN
Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit -1...25 -1...10 -1...4 -0.124...2.5 -0.05...1 -0.0124...0.25 -1...1 -0.005...0.1 100 50 30 20 10 10 10 4 350 150 100 50 30 30 30 30 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 8 8 8 8 8 8 8 8 12 12 12 12 12 12 12 12 PI2793 PI2794 PI2795 PI2796 PI2797 PI2798 PI2799 PI2789
www.ifm.com
157
Pressure sensors
Electronic contact manometers for hygienic and wet areas with switching output and analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.
M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP/NPN
Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario G G G G G G G G Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit -1...25 -1...10 -1...4 -0.124...2.5 -0.05...1 -0.0124...0.25 -1...1 -0.005...0.1 0...250 0...100 -1...25 -1...10 -0.125...2.5 -0.05...1 -0.0125...0.25 -0.005...0.1 100 50 30 20 10 10 10 4 600 300 100 50 20 10 10 4 350 150 100 50 30 30 30 30 1000 700 300 150 50 30 30 30 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 13 13 13 13 13 13 13 13 14 14 14 14 14 14 14 14 PG2793 PG2794 PG2795 PG2796 PG2797 PG2798 PG2799 PG2789 PG2451 PG2452 PG2453 PG2454 PG2456 PG2457 PG2458 PG2489
M12 connector Output function 1 x normally open / normally closed programmable + 1 x normally open / normally closed programmable or 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP
G1 A G1 A Display unit Display unit -1...25 -1...10 100 50 350 150 18...32 18...32 10 10 11 11 PIM693 PIM694
PF sensors for hygienic and wet areas with switching and analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.
M12 connector Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V; scaleable 1:4) DC PNP/NPN
G1 A Switching status -1...100 200 650 20...30 8 15 PF2652
G1 A G1 A G1 A G1 A G1 A
Switching status Switching status Switching status Switching status Switching status
100 50 20 10 10
350 150 50 30 30
8 8 8 8 8
16 16 16 16 16
www.ifm.com
158
Pressure sensors
PL / PM sensors without display for hygienic and wet areas with analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.
E10017
Protective cover for fluid sensors with connector M12 Housing materials: polyurethane
E30006
Protective cover for fluid sensors stainless steel with transparent Teflon window Housing materials: stainless steel 316Ti / 1.4571 / PFA / EPDM / ventilation strip: Teflon film 0.32 mm / O-ring: EPDM
E30104
Programming/ display unit for EPS and IO-Link sensors Connector Housing materials: stainless steel 316L / 1.4404 / EPDM/X / PC copolymer / PBT / FPM
PP2001
Protective cover with lead seal option for pressure sensors type PK for temperature sensors type TK for vibration monitor VK Housing materials: PP transparent
E30094
IO-Link interface for parameter setting and analysis of units with DTM specification Supported communication protocols: IO-Link (4800 and 38400 bits/s) EPS protocol (19200 bits/s) contains ifm Container software (E30110)
E30396
Cable clamp fastener for submersible pressure transmitter PS3 Housing materials: steel / plastics
E30399
www.ifm.com
159
Pressure sensors
Type
Description
Order no.
Filter element for submersible pressure transmitter PS3 for fixing on the capillary tube
E30400
Splitter box with ventilation and terminal block for submersible pressure transmitter PS3 Housing materials: plastics
E30401
Additional weight for submersible pressure transmitter PS3 Housing materials: stainless steel 316Ti / 1.4571
E30402
E30007
E30116
Flange adapters
Type Description Order no.
Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33201
Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33202
Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33701
Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33702
Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33222
Aseptoflex Vario adapter Varivent type F DN25 (1), D = 50 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33721
Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33722
www.ifm.com
160
Pressure sensors
Type
Description
Order no.
Welding adapter 50 mm for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E30122
Adapter plug for Aseptoflex Vario adapter Housing materials: high-grade stainless steel
E30128
Aseptoflex adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex adapter Housing materials: stainless steel 316L / 1.4404
E33001
Aseptoflex adapter Clamp 2 ISO 2852 for units with Aseptoflex adapter Housing materials: stainless steel 316L / 1.4404
E33002
Welding adapter 50 mm with Aseptoflex thread Housing materials: stainless steel 316L / 1.4404 / O-ring: FPM FDA compliant
E30052
Adapter plug for welding adapter with Aseptoflex thread Housing materials: high-grade stainless steel
E30064
Wiring diagrams
1
1
L+
4 2
2: Out 2 4: Out 1
L+
BN WH
L+ L
2
L
GY
2
1
L+
6
1 PA+ n.c. n.c. PA
2
4
1
2 3
L+
2 4
4: 2:
8
1
L+
2: Out 2 4: Out 1
1 2 4
3
L+
1 4
2
L+
1
2
L+
4 3
L L
2: Out 2 4: Out 1
4
3
L+
L+
2
4
2: Out 2 4: Out 1 2: Out 2 4: Out 1
4 2
L
www.ifm.com
161
Pressure sensors
Wiring diagrams
9
1
1 L+
11
2
1 2 4 L 3 L+ L P L 1 L+ 1 2 2 L 3 L L+
1 2 4
L+
1 2 4
L+
4: Out 1 2: Out 2
4: Out 1 2: Out 2
3
2 34 3 47
1 91,5
M12 x1
1 91,5
M12 x1 30 G 1/4
35 42 20,7 11,3 32 4,2 32
57,3
1,3
1,3
14
21,5 27
21,5 30 G 1/4 27
1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button 2
2
34
1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button 4
3
47,8
1 94,1
M12 x1
59,6
4,75
21,5 27 30 G 1/4
1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button
16,5
1,3
20
30
1: main pressure connection G 1/8; tightening torque max. 8 Nm, thread length max: 7.5 mm, 2: for mounting screw M4; max. tightening torque 2.5 Nm, 3: LEDs (display unit / switching status), 4: 4digit alphanumeric display, 5: Programming button
www.ifm.com
162
14
57,3
Pressure sensors
10
2 3 47
48 34
61,6 71,6
7,5
1 12 119
36 14,5
36 22 M12 x1
1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: Aseptoflex sealing edge, 5: Aseptoflex thread
51,2 65,1
11
2 48 34 3 47
22 1
G/
14
12
7
30 M12 x1 27 119 85 41 1,3 16,5
77,5
25,4 G1
20
30
G1 4 21,5 27
8
30 M12 x1
M12 x1
G1
75
1,3
30
G1 4 21,5 27
34
www.ifm.com
27
16,8
14
52,8
105,8
M12 x1
85
27 2
M5 G 1/4
M12 x1
163
Pressure sensors
16
1 48,5 34 2 46,5
M12 x1
153
97,4
M12 x1 3 24
G1
16,8
60,5
27,5
25,4 G1
41
20
M12 x1
169
15
107 121,5
36
75,5
22
G1 2
24
92
M12 x1
58
36 1 2
M12 x1
27,5
25,4 G1
41
20
www.ifm.com
164
14,5
108 122,8
63,1
Pressure sensors
165
166
Temperature sensors
Selection chart
Compact temperature sensors Compact temperature sensors with display Control monitors for temperature sensors Control monitors for temperature sensors Pt1000 probe sensors for standard applications Pt100 probe sensors for standard applications Cable sensors for standard applications Cable sensors with bolt-on sensor for standard applications Temperature transmitters for standard applications AS-i temperature transmitters for standard applications Probe sensors for hygienic and wet areas Cable sensors for hygienic and wet areas Temperature transmitters for hygienic and wet areas AS-i temperature transmitters for hygienic and wet areas Self-monitoring temperature transmitters for hygienic and wet areas Profibus-Temperaturtransmitter mit ATEX-Zulassung 1G, 1/2GD, 2GD Accessories for temperature sensors TN / TR Accessories and software Adapters Thermowells for temperature sensors Flange adapters Wiring diagrams Scale drawings - CAD download: www.ifm.com
Page
169 169 169 - 170 170 170 171 171 171 171 172 172 172 172 173 173 173 173 173 174 - 175 175 175 - 176 176 - 177 177 - 180
www.ifm.com
167
Temperature sensors
Increased process safety due to self-monitoring. Compact units with integrated sensors or modular systems. Robust construction for high resistance to shock and vibration. Direct contact with medium or thermowell mounting. Units with diverse redundant sensors for critical tasks.
Temperature sensors The controlling and monitoring of temperatures are amongst the most important measuring tasks in automation and process technology. In process technology for example the right temperature is decisive for the quality and efficiency of the process. In automation technology an exact temperature detection is very important for monitoring installations and as protection against dangerous states. In heating and air conditioning economic and easy operation is not possible without temperature measurement and control. Operating principle The temperature sensors of ifm electronic are based on a Pt100 or Pt1000 resistor. The measured temperature value corresponds to a change in resistance and is converted into an electrical analogue signal. The microprocessor and the display make process adjustment much easier. The user can set the values for the switch points, hysteresis and measuring range by means of programming buttons even without the system temperature being applied. This enables installation and setup of the system within a few minutes. Film technology is used for the electronic circuitry. A flexible, temperature-resistant and extremely resistant polyimide film is used as carrier of the SMD components. Together with a special potting method an extreme shock and vibration resistance is achieved. From sensor to system A complete temperature measurement system usually consists of several components. The temperature in a medium is detected by a sensor and is converted into an electrical measured signal. The mechanical design and the dimensions of the sensors must vary to enable use for different media and measuring points. ifm electronic offers a selection of robust probe sensors or types with connection cables. To indicate and process the measured value the sensor is connected to a separate control monitor. For further processing, freely programmable switching or analogue outputs are available. If a local temperature display is not required, temperature transmitters are frequently used. ifm electronic provides units with excellent response times (TA series) that either have standard output signals or an integrated AS-i interface. In hygienic applications the self-monitoring, calibration-free temperature transmitter TAD is an excellent choice.
Local display of the current temperature.
www.ifm.com
168
Temperature sensors
-25...140
NPT
35
9.6...32
1/3
TK6330
DC PNP
25 9.6...32 1/3 2 1 TK7130
-25...140
NPT
35
9.6...32
1/3
TK7330
M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V, scalable) DC PNP/NPN
-40...150 M18 x 1.5 45 18...32 1/3 7 4 TN2531
www.ifm.com
169
Temperature sensors
Type
Process connection
Display LED
Ub [V]
Iload [mA]
Drawing no.
Order no.
M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V, scalable) DC PNP/NPN
-40...300 G A Display unit 20...30 55 250 10 5 TR2432
10 10 10 8.2
3 3 3 3
9 9 9 10
-40...150
10
50
1 x Pt 1000
5 / 14
11
TM0061
www.ifm.com
170
Temperature sensors
-40...150
10 / L = 45
1 x Pt 1000
6 / 25
13
TS2051
-50...250
6 / L = 50
PTFE cable
1 x Pt 100
11 / 37
14
TS2256
-50...250
10 / L = 50
PTFE cable
1 x Pt 100
12 / 39
15
TS2056
www.ifm.com
171
Temperature sensors
www.ifm.com
172
Temperature sensors
M12 connector Output function normally open / normally closed / heartbeat programmable, 4...20 mA analogue DC PNP/NPN
-25...150 Aseptoflex Vario 87.5 15...32 3/6 13 22 TAD181
-25...150
Aseptoflex Vario
33
15...32
3/6
13
23
TAD981
-25...150
Aseptoflex Vario
33
9...32
3/6
25
TAP98A
E10017
Protective cover for fluid sensors with connector M12 Housing materials: polyurethane
E30006
IO-Link interface for parameter setting and analysis of units with DTM specification Supported communication protocols: IO-Link (4800 and 38400 bits/s) EPS protocol (19200 bits/s) contains ifm Container software (E30110)
E30396
www.ifm.com
173
Temperature sensors
Adapters
Type Description Order no.
Thread cover 26 mm - G to cover the G thread for installation in hygienic areas for type TA Housing materials: stainless steel 316L / 1.4404
E30090
Mounting set for direct connection of temperature sensors TT to control monitors TR Housing materials: stainless steel
E30017
Mounting set G for direct connection of temperature sensors TM to control monitors TR Housing materials: stainless steel 316L / 1.4404 / stainless steel
E30089
Clamp fitting 6/8/10 mm - G for temperature sensors TS / TT Housing materials: stainless steel / FPM
E30018
Clamp adapter 10 mm - G no dead space Housing materials: stainless steel 316L / 1.4404 / FPM
E34410
Welding adapter M18 x 1.5 - 24 mm Insertion depth of the probe of SID, SFD, TN: 15 mm Housing materials: stainless steel 316L / 1.4404
E40124
E30055
E30056
Welding adapter 50 mm for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E30122
Progressive ring fitting for temperature sensors 10 mm - G Housing materials: stainless steel 316Ti / 1.4571
E30016
Progressive ring fitting for temperature sensors 6 mm - G Housing materials: stainless steel 316Ti / 1.4571
E30047
Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: titanium
E40114
Adapter M18 x 1.5 - M12 x 1 Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: titanium
E40128
Adapter M18 x 1.5 - M12 x 1 Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: stainless steel 316L / 1.4404
E40101
www.ifm.com
174
Temperature sensors
Type
Description
Order no.
Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: stainless steel 316L / 1.4404
E40099
Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: stainless steel 316L / 1.4404
E40096
Adapter M18 x 1.5 - NPT Insertion depth of the probe of SID, SFD, TN: 23 mm Housing materials: stainless steel 316L / 1.4404
E40107
G adapter Clamp 1-1.5 DIN 32676 for units with G adaptation Housing materials: stainless steel 316L / 1.4404
E33401
G adapter Clamp 2 DIN 32676 for units with G adaptation Housing materials: stainless steel 316L / 1.4404
E33402
Protective cover with lead seal option for pressure sensors type PK for temperature sensors type TK for vibration monitor VK Housing materials: PP transparent
E30094
Welding thermowell 35 mm Probe length: 126.5 mm for type TA343x, TAA431, TAD191 Housing materials: stainless steel 316L / 1.4404
E30403
Thermowell for temperature sensors G Probe length: 53 mm for type TA34xx, TAA431, TAD191 Housing materials: stainless steel 316L / 1.4404
E30393
Thermowell for temperature sensors 10 mm - G Probe length: 82 mm Housing materials: stainless steel 316L / 1.4404
E35010
Thermowell for temperature sensors 6 mm - G Probe length: 82 mm Housing materials: stainless steel 316Ti / 1.4571
E37010
Flange adapters
Type Description Order no.
Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33202
Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33702
www.ifm.com
175
Temperature sensors
Type
Description
Order no.
Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33201
Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33701
Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435
E33222
Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435
E33722
Wiring diagrams
1
1
L+
3
1 2 3
2
4
AS-i+
4: 2:
AS-i
2
1
L+
6
1 PA+ n.c. n.c. PA
4 2
2: Out 2 4: Out 1
L+
2 4
2
L
9
1
L+
Out 2 Out 1 Out 3 Out 4 n.c.
1 2 4
3
L+
1 4
2
L+
1 (n.c.)
2
3 (n.c.)
4 5
TR 8430
6
7 3
1 2 4 2: Out 2 4: Out 1 3
L+
1 2 4 2: Out 2 4: Out 1
L+
www.ifm.com
176
Temperature sensors
Wiring diagrams
10
1
12
B 1 B
2 3 4 1 1 BN 2 WH 4 BK TR 2432 3 BU
B 1 L+ B
2 3 4
B 2
1 2
1 2
TP
2 3 4
L+ L IO-Link L
3 4
L 2
1 2 3 4
4 3
3 4
1: Two-wire sensor, 2: Four-wire sensor, 3: Operation as 2-wire temperature transmitter, 4: Operation as 3-wire unit, IO-Link communication possible, B: link 13
B 1 B
2 3 4 1 1 BN 2 WH TR 4 BK 3 BU
1
1 BN
2
1 BN
B 2
1 2
2 3 4
L+
2 WH
L+
2 WH 4 BK
L+
3 BU
3 4
2
27 M12 x1
87
14
8,2 8,2
www.ifm.com
35 48
G1 4
25
27
39
27 -18 NPT
96
105,5
96,5
177
Temperature sensors
6
2 34 3 48
327
93
M12 x1 G1 2 16,5 30 4
23,5 M12x1 LED 17 M12x1 2
27
255 267
G1 2
1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: connection for temperature sensor 7
4
2 34 3
48
M12x1
14
128
94,5
45
1: connection for voltage supply and output signals, 2: connection for temperature sensor
22 4
8,2
8
21,5 6,2 L
5
2 34 3 48
18,5 M12x1
1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: internal thread M18 x 1.5
20 50
40 1
1: plug area
M12 x1 1 93
9
21,5
M12x1
18,5
60
16,5
40 1 30 4
G1 2
1: plug area 1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: connection for temperature sensor 10
M12x1
8,2
www.ifm.com
178
44
60
22
90
19
14
12
8 10
5,95
13,8
60
Temperature sensors
17
30 M12x1
13,7
36 M12x1
30
72 6 48 45
M12 x1
8,2
18 13
7 10
46 45
30 M12x1
14,9 53
LED
M12 x1
12
60 13,5
12
27
G1 4
13,5 27 6 G1 4
14
42,5
50
M12 x1
8,2
15
50 42
19
180,5
7 10
42,5
13,7
43,8
123 87,5
M12 x1
60
127,9
117,7
44
30 M12x1
16
51 14 35 12
LED
27
G1 2
20
171 14 30 M12x1 34 123 6
17 1,8 8,7
M12 x1
49,5
6,5
21
190,5 14,7 52,8 123 87,5
30 M12x1
8,2 10 18,3
47,5
LED
27
G1 2
www.ifm.com
18,3
12
8,2 10
47,5
179
Temperature sensors
24
210,5 195,7 140,5 87,5 8 10 50,4 M12x1 1 34 G1
50,4 M12x1
34
G1
23
156 141,2 86 33 8 10
1: Grounding screw 25
156 141,2 86 33 8 10 34 G1 1 34 G1
50,4 M12x1
1: Grounding screw
www.ifm.com
180
50,4 M12x1
Temperature sensors
181
182
Diagnostic systems
Selection chart
Compact vibration diagnostic units with g-monitor to ISO 10816 type VB/VE Accessories VB / VE Vibration monitors for vibration monitoring of machines and plants to ISO 10816 type VK Accessories VK Diagnostic electronics - control cabinet modules for vibration diagnosis type VSE Accessories VSE Vibration sensors for connection to external diagnostic electronics VSE - type VSA Accessories VSA Scale drawings - CAD download: www.ifm.com
Page
185 185 185 186 186 186 186 - 187 187 187 - 188
www.ifm.com
183
Diagnostic systems
Online vibration diagnosis optimum price / performance ratio. Decentralised monitoring of plant and equipment integrated into the machine. Compact field units and modular control cabinet units. Digital and analogue alarm outputs. Standard data interface (OPC).
Diagnostic systems efector octavis is a vibration monitor which not only detects vibration data, but also carries out signal analysis and machine diagnosis directly on the machine. The machine condition is determined and is forwarded to the PLC or to SCADA software. It fulfils the main requirements for modern machine monitoring: compatibility, modularity and transferable configuration. Compatible and modular The compatibility with data structures such as the OPC interface makes it possible to integrate condition data into a higher-level system. With the requirement for modularity the user can define the extent of condition monitoring to be implemented this means the complete range of diagnosis is possible right from the first unit. Transferable configuration is attained with application-related parameter sets. A wizard function in the software guides the user through creating, managing and archiving the monitoring parameters. Trend memory All units of the octavis family type VE / VSE feature an internal trend memory which ensures detailed analysis and optimisation of the application even without external data recording. The storage intervals are freely selectable. This means that the storage length of the non volatile ring-memory is adjusted to the requirements. The suitable system for your application: Standard vibration characteristic values / permanent machine protection: VSE, VE, VK Internal trend memory / root cause analysis: VSE, VE Online diagnosis / early damage detection: VSE (VE partly) Network capability of the system: VSE (VE partly*) *Profibus DP gateway
Easy vibration monitoring: type VK provides a combination of switching output and transmitter function in conjunction with the tried and tested easy-turn concept.
Internal trend memory (type VE / VSE) of all monitored diagnosis factors can be evaluated via PC software.
www.ifm.com
184
Diagnostic systems
Compact vibration diagnostic units with g-monitor to ISO 10816 type VB/VE
Type Description Drawing no. Order no.
Vibration diagnostic unit Spectral analysis / FFT Envelope-curve FFT Peak V eff RMS Trend analysis Connection via M12 x 1 and M8 x 1 connectors housing: diecast zinc nickel-plated / keypad: polyester
VE1001
Vibration diagnostic unit Spectral analysis / FFT Envelope-curve FFT Peak V eff RMS Trend analysis Connection via M12 x 1 and M8 x 1 connectors housing: diecast zinc nickel-plated
VE1101
Vibration diagnostic unit ATEX approval Group II, category 2D Group II, category 2G Spectral analysis / FFT Envelope-curve FFT Trend analysis Cable housing: diecast zinc
VE113A
Accessories VB / VE
Type Description Order no.
Parameter setting cable for efector octavis ifm electronic straight / straight 3 m Housing materials: PUR
E11572
E30098
Y connection cable ifm electronic 2 way Free from halogen 0.25 m Housing materials: TPU
E11664
Vibration monitors for vibration monitoring of machines and plants to ISO 10816 type VK
Type Description Drawing no. Order no.
Vibration monitor Connection via M12 connector Vibration monitor to DIN ISO 10816 Measuring range Veff: 0...25 mm/s Switching outputs: normally closed and analogue 4...20 mA PBT / PC / FPM / stainless steel 316L / 1.4404
VKV021
Vibration monitor Connection via M12 connector Vibration monitor to DIN ISO 10816 Measuring range Veff: 0...50 mm/s Switching outputs: normally closed and analogue 4...20 mA PBT / PC / FPM / stainless steel 316L / 1.4404
VKV022
www.ifm.com
185
Diagnostic systems
Accessories VK
Type Description Order no.
Protective cover with lead seal option for pressure sensors type PK for temperature sensors type TK for vibration monitor VK Housing materials: PP transparent
E30094
Diagnostic electronics - control cabinet modules for vibration diagnosis type VSE
Type Description Drawing no. Order no.
Diagnostic electronics for vibration sensors Ethernet interface Switching output, Analogue output Combicon connection PA
VSE002
Diagnostic electronics for vibration sensors 4 sensor inputs 0...10 mA Ethernet interface Switching output, Analogue output Combicon connection PA
VSE100
Accessories VSE
Type Description Order no.
E30112
Vibration sensors for connection to external diagnostic electronics VSE - type VSA
Type Description Drawing no. Order no.
Vibration sensor for connection to external diagnostic electronics Connector housing: stainless steel 316L / 1.4404
VSA001
Vibration sensor for connection to external diagnostic electronics Cable with connector housing: stainless steel 316L / 1.4404
VSA002
www.ifm.com
186
Diagnostic systems
Type
Description
Drawing no.
Order no.
Vibration sensor for connection to external diagnostic electronics type VSExxx Cable housing: stainless steel 316L / 1.4404
VSA003
Accessories VSA
Type Description Order no.
conical washer 8.4 / 15 mm for efector octavis Housing materials: stainless steel 316Ti / 1.4571
E30115
3
62,2 46,4
M12 x1 36
14
14
36
5,3 6 1 M8 x1
20
M5
6 4
5,3
20
M5
37,6 10
37,6 10
5,3 5
LED
5,3
4 1: Programming buttons 2
58,2 46,4
27 M12 x1
M12 x1 36
14
6 4
5,3
20
M5
27 M8
37,6 10
5,3
www.ifm.com
M8x1
1: tightening torque 15 Nm
11
63,7 73,1
187
Diagnostic systems
7
M8x1,25
24
18,5
M12 x1 11,5 17
53
17
35,5
100
LEDs
1: conical angle = 90 8
22 18 5 14 M16x1,5 50 105 13
1: Ethernet interface 6
9
1500 35,5
114
12
LEDs
18 5,5
1 2
www.ifm.com
188
Diagnostic systems
189
190
Selection chart
Controllers, gateways and software AS-i repeaters AS-i power supplies I/O modules for control cabinets Field modules IP67 Field modules IP69K and accessories Module lower parts Pneumatic and actuator solutions Safety at Work AS-i sensors Combicon connectors Flat cable splitters and accessories Accessories Safety at Work Accessories lower parts and addressing units Accessories pneumatic components Accessories RFID Scale drawings - CAD download: www.ifm.com
Page
193 193 194 194 - 195 195 - 196 196 196 - 197 197 197 - 198 198 198 199 199 199 - 200 200 200 201 - 206
www.ifm.com
191
Manufacturer-independent standard. Worldwide acceptance as a wiring system. Communication from the sensor to the controller. Safety at Work for safety-related applications. Intelligent system solutions for special tasks.
Bus system AS-interface AS-interface (AS-i = actuator sensor interface) is a manufacturer-independent standard for the connection of actuators and sensors of the first field level. It is the only wiring system accepted worldwide. With 15 million slaves installed AS-i has been tried and tested as a low-cost feeder for all common fieldbuses for many years. The product range includes AS-i components for different areas from packaging and conveying via silo applications, machine tools, robotics and automation to the food industry and mobile vehicles. Safe The sophisticated AS-i technology and the extended diagnostic possibilities provide high reliability and machine uptime. Safety at Work is the extension of the AS-interface by safety-related components. Safety components up to the highest control category 4 to EN 954-1, SIL 3 to IEC 61508 and EN ISO 13849 - 1 / PL e can be connected to AS-i. Easy Due to the standardised system, the low wiring complexity and the quick connection technology, AS-i enables simple Plug & Play. The reduction of terminals leads to reduced documentation. Data and energy are jointly transmitted via a two-wire cable. The reverse polarity protected insulation displacement technology helps avoid errors. The modularity and the tree structure smoothly fit to the way the plant is put together. Cost-optimised Its the end result that matters: wiring complexity, documentation and set-up times are significantly reduced. The decentralisation of the AS-i participants leads to smaller and less expensive control cabinets. Simple diagnosis and a clear system design result in high machine uptime and avoid downtimes.
Reduced cost: reduced wiring complexity for faster installation and fewer error sources.
www.ifm.com
192
SmartLink DP AS-i gateway / Profibus DP Full master functions Graphic display Housing materials: aluminium / steel sheet galvanised
AC1375
AS-i DP gateway Full master functions Graphic display Profibus DP interface Housing materials: aluminium / steel sheet galvanised
AC1376
AS-i DP gateway Full master functions Graphic display Profibus DP interface Housing materials: aluminium / steel sheet galvanised
AC1326
AS-i Ethernet / IP Controller E Full master functions Graphic display Housing materials: aluminium / steel sheet galvanised
AC1327
AS-i Ethernet / IP Controller E Full master functions Graphic display Housing materials: aluminium / steel sheet galvanised
AC1337
AS-i controller E AS-i controller freely programmable Full master functions Graphic display Ethernet programming interface Housing materials: aluminium / steel sheet galvanised
AC1354
AS-i repeaters
Type Description Drawing no. Order no.
AS-i repeater Extension of the AS-i network by another 100 m One additional AS-i power supply necessary Combicon connection PA 6.6
AC2225
Passive AS-i bus termination Extension of the cable to a maximum of 200 m without additional repeater Improvement of the signal quality Monitoring of the supply voltage by means of LEDs
AC1147
AS-i tuner diagnostic module Extension of the cable to a maximum of 200 m without additional repeater Monitoring of the message quality Display of critical states by traffic light LEDs PBT
AC1146
www.ifm.com
193
0.95
Power supply AS-i Netzteil 100...240 V DC Integrated data decoupling 30 Watt PC / ABS
AC1220
1.9
Power supply AS-i Netzteil 100...240 V DC Integrated data decoupling 60 Watt PC / ABS
AC1221
2.8
Power supply AS-i Netzteil 100...240 V DC Integrated data decoupling AlMg3 / steel sheet galvanised / polycarbonate
AC1236
Power supply AS-i Netzteil 100...240 V DC Integrated data decoupling AlMg3 / steel sheet / polycarbonate
AC1244
2x4
Power supply AS-i dual power supply 115/230 V AC 2 x AS-i Integrated data decoupling aluminium
AC1212
Power supply AS-i power supply 115/230 V AC Integrated data decoupling Jumper to deactivate the AS-i communication 240 watts aluminium / steel sheet galvanised
AC1218
4 inputs
Active AS-i module String mounting possible Addressing socket Input supply from external PELV voltage source Version 2.1 with extended addressing mode Digital inputs Combicon connection PA
10
AC2254
4 outputs
Active AS-i module String mounting possible Addressing socket Version 2.1 Digital outputs Combicon connection PA
10
AC2252
4 inputs / 3 outputs
Active AS-i module String mounting possible Addressing socket Version 2.1 with extended addressing mode Digital inputs and outputs Combicon connection PA
10
AC2264
4 inputs / 4 outputs
Active AS-i module String mounting possible Addressing socket Version 2.1 Digital inputs and outputs Combicon connection PA
10
AC2251
Active AS-i module String mounting possible Addressing socket External sensor supply PELV Version 2.1 Digital inputs and outputs Combicon connection PA
10
AC2257
4 inputs 4...20 mA
Active AS-i module AS-i profile S-7.3 4 analogue inputs 4...20 mA For the connection of 2-wire, 3-wire or 4-wire sensors Combicon connector for sensor connection PA 6.6
10
AC2216
11
AC2729
www.ifm.com
194
Type
Inputs / outputs
Description
Drawing no.
Order no.
4 inputs / 3 outputs
Active AS-i module AS-i version 2.1 with extended addressing mode
12
AC2730
4 inputs
Active ClassicLine module Version 2.11 and 3.0 with extended addressing mode Addressing socket Three orientations of the flat cable are possible Digital inputs Sockets M12 x 1 PA
13
AC5215
4 outputs
Active ClassicLine module Addressing socket Three orientations of the flat cable are possible Digital outputs Sockets M12 x 1 PA
13
AC5208
2 outputs / 2 inputs
Active ClassicLine module Version 2.11 and 3.0 with extended addressing mode Addressing socket Three orientations of the flat cable are possible Digital outputs and inputs Sockets M12 x 1 PA Active ClassicLine module Addressing socket Three orientations of the flat cable are possible Version 2.11 and 3.0 with extended addressing mode Digital inputs and outputs Sockets M12 x 1 PA Active ClassicLine module Only for operation with AS-i masters with the profile M4 Addressing socket Three orientations of the flat cable are possible Version 3.0 with extended addressing mode Digital inputs and outputs Sockets M12 x 1 PA
13
AC5214
14
AC5204
14
AC5235
Active module upper parts AS-i illuminated pushbutton module Power supply via AS-i cable Colour inserts changeable PBT
15
AC2086
2 inputs 4...20 mA
Active ClassicLine module 2 analogue inputs 4...20 mA For the connection of 2-wire and 3-wire sensors Addressing socket Three orientations of the flat cable are possible PA
13
AC5222
4 inputs
Active CompactLine module Version 2.1 with extended addressing mode IR addressing possible Digital inputs Sockets M12 x 1 PUR
16
AC2457
4 inputs
Active CompactLine module IR addressing possible high-grade stainless steel Digital inputs Sockets M12 x 1 PA / stainless steel 316L / 1.4404
16
AC2451
4 outputs
16
AC2417
2 inputs / 2 outputs
Active CompactLine module IR addressing possible Digital inputs and outputs Sockets M12 x 1 PA
16
AC2411
www.ifm.com
195
Type
Inputs / outputs
Description
Drawing no.
Order no.
Active CompactLine module IR addressing possible Digital inputs and outputs Sockets M12 x 1 PA
17
AC2412
Active CompactLine module IR addressing possible Digital inputs and outputs Sockets M12 x 1 PA / stainless steel 316L / 1.4404
17
AC2452
4 inputs / 3 outputs
Active ProcessLine module Version 2.1 with extended addressing mode Protection rating IP 69K high-grade stainless steel Digital inputs and outputs Sockets M12 x 1 high-grade stainless steel / Makrolon / O-ring: EPDM Active ProcessLine module Version 2.1 with extended addressing mode Protection rating IP 69K high-grade stainless steel Digital inputs Sockets M12 x 1 high-grade stainless steel / Makrolon / O-ring: EPDM Passive splitter box AS-i ProcessLine Protection rating IP 69K high-grade stainless steel AS-i and AUX splitter box for the connection of intelligent sensors/actuators Sockets M12 x 1 high-grade stainless steel / Makrolon
18
AC2904
19
AC2910
20
AC2900
4 inputs 4...20 mA
Active AS-i module 4 analogue inputs 4...20 mA For the connection of 2-wire and 3wire sensors Threaded bush: stainless steel 316L / 1.4404 / Makrolon / O-ring: EPDM
21
AC2916
AS-i / 24 V
FC splitter V4A AS-i voltage and external auxiliary voltage via the M12 socket Metal parts: stainless steel 316L / 1.4404 / Blanks: FPM / O-ring: EPDM
E70354
AS-i
FC splitter AS-i voltage via M12 socket Metal parts: stainless steel 316L / 1.4404 / Oring: EPDM / socket: PP GF30 / blade seal: TPE
E70454
FC coupling module
Module lower part flat cable AS-i interface to module upper part Quick mounting technology for AS-i flat cable PBT
22
AC5000
FC-E coupling module AS-i interface to module upper part Quick mounting technology for AS-i flat cable PBT
22
AC5003
FC coupling module
Module lower part flat cable stainless steel AS-i interface to module upper part Quick mounting technology for AS-i flat cable PBT / stainless steel
22
AC5014
FC-E coupling module stainless steel AS-i interface to module upper part Quick mounting technology for AS-i flat cable PBT / stainless steel
22
AC5015
www.ifm.com
196
Type
Inputs / outputs
Description
Drawing no.
Order no.
SC coupling module
Module lower part set AS-i interface to module upper part Screw terminal PBT
23
AC5031
AS-i AirBox 2 x 3/2-way slide valves free from overlapping Three orientations of the flat cable are possible AS-i flat cable connection Version 2.11 and 3.0 with extended addressing mode Addressing socket PA / POM AS-i AirBox 5/2-way slide valve free from overlapping Three orientations of the flat cable are possible AS-i flat cable connection Version 2.11 and 3.0 with extended addressing mode Addressing socket PA / POM
24
AC5228
25
AC5246
Safety at Work
Type Description Drawing no. Order no.
AS-i safety monitor Basic version 2-channel Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e Configuration and setup by configuration software ASIMON Screw terminal polyamide black
26
AC002S
AS-i safety monitor Extended functionality 2-channel Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e Configuration and setup by configuration software ASIMON Screw terminal
26
AC004S
AS-i safety monitor Extended functionality and integrated safe slave for triggering a safe AS-i output 1-channel Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e Configuration and setup by configuration software ASIMON V3.0 Screw terminal polyamide black AS-i safety monitor Extended functionality and integrated safe slave for triggering a safe AS-i output 2-channel Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e Configuration and setup by configuration software ASIMON V3.0 Screw terminal
27
AC031S
27
AC032S
Safe active AS-i module Control category 4 according to EN954-1 and IEC 61508 / SIL 3 For the connection of mechanical contacts Combicon connection
28
AC009S
Safe active AS-i output module Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e for the safe triggering of actuators Combicon connection
29
AC030S
Safe active AS-i module Connection via M12x1 sockets or cage clamps Control category 4 according to EN954-1 and IEC 61508 / SIL 3 Version 2.1 For connection of an electro-sensitive protective equipment (ESPE) type 4 to EN 61496-1 AS-i interface to FC-E lower parts
30
AC007S
Safe AS-i input module IR addressing possible AS-i version 2.1 Performance Level e to EN ISO 13849-1 for the connection of mechanical contacts Sockets M12 x 1 PBT
31
AC005S
www.ifm.com
197
Type
Description
Drawing no.
Order no.
Illuminated E-STOP with integrated AS-i connection Connector M12 x 1 AS-i interface via AS-i flat cable IP 67 foolproof E-STOP to EN ISO 13850 / EN 418 Pull to reset
32
AC010S
safe AS-i e-stop operating unit with integrated AS-i connection AS-i interface via M12 x 1 connector fool-proof E-STOP to EN ISO 13850 / EN 418 Pull to reset interchangeable button inserts
33
AC012S
AS-i safety PCB Connection of mechanical contact and LED components Certification according to EN 954-1 / category 4 and IEC 61508 / SIL 3
11
AC015S
AS-i sensors
Type Description Drawing no. Order no.
Read/write head DTSLF AARWASUS01 with integrated AS-i slave profile 7.4 M12 connector PA
34
DTA100
Read/write head DTSLF DCRWASUS01 with integrated AS-i slave profile 7.4 M12 connector housing: PPE / Metal parts: diecast zinc / brass nickel-plated
35
DTA300
Combicon connectors
Type Description Order no.
Combicon connector with screw terminals 4-pole Housing materials: current carrying parts: copper alloy tin-plated Pack quantity: 6
E70230
Combicon connector with screw terminals 4-pole Housing materials: current carrying parts: copper alloy tin-plated Pack quantity: 100
E70231
www.ifm.com
198
FC splitter AS-i voltage via M12 socket Housing materials: Metal parts: stainless steel 316L / 1.4404 / O-ring: EPDM / socket: PP GF30 / blade seal: TPE
E70454
FC splitter V4A AS-i voltage and external auxiliary voltage via the M12 socket Housing materials: Metal parts: stainless steel 316L / 1.4404 / Blanks: FPM / O-ring: EPDM
E70354
FC insulation displacement connector Socket M12 - AS-i flat cable Housing materials: PA
E70096
Protective cap M12 for M12 sockets of ClassicLine modules, CompactLine modules and AirBoxes Housing materials: PA black
E73004
Protective cap M12 for M12 socket to cover the unused inputs and outputs on the module; for unused inputs of splitter boxes for ProcessLine modules Housing materials: PVC
E70297
Connection cable PC / AS-i safety monitor Parameter setting cable PC / AS-i safety monitor Western connector RJ 45 8 poles / DSub socket 9 poles 2.5 m
E7001S
E7005S
AS-i addressing unit AS-i version 2.1 with extended addressing mode
AC1144
E70213
Programming cable for controller E Western connector RJ11 6 poles / D-Sub socket 9 poles 1.55 m
E70320
AC5031
www.ifm.com
199
Type
Description
Order no.
AC3000
AS-i flat cable reverse polarity protection due to special shape for use in isolation displacement connector technology for FC lower parts and compact modules
AC4000
AS-i flat cable reverse polarity protection due to special shape for use in isolation displacement connector technology for FC lower parts and compact modules
AC4002
AS-i flat cable for the food industry reverse polarity protection due to special shape 100 m
AC4007
AS-i flat cable for the food industry reverse polarity protection due to special shape 100 m
AC4008
E70062
Flat cable seal Housing materials: ULTRAMID / sealing: NBR Pack quantity: 10
E70413
E75232
Accessories RFID
Type Description Order no.
ID tag ID-TAG/TRIANGEL HOUSING/01 with ID tag E80301 Housing materials: PBT orange (RAL 2003) / PA black (RAL 9005)
E80302
E80317
E80320
www.ifm.com
200
4
86 62
124 138
LED
LED
124 131
57 68
97 107
5 2
86
44
83
62
M12 x1
124 131
LED
LED
90
LED 97 107
4
90
LED
LED
45
100
97 107
www.ifm.com
201
21
LED
129 136
44
32
9 10 10
50
136 144
12
88
8
118,5 113
120
13
134
9
91
14
124 131
Jumper LED
96 107
10
25
105
LEDs
1: Addressing socket
www.ifm.com
202
35,5
114
44
UU U
19
137,3 80
30
16
118
45
M12 x1
LED
43,6
17 24
20
137,3 80
36
39 60
LED
M12 x1
107
FE
4,5
17
152
M12 x1
17 24
43,6
21
137,3
36 39 60
80
LED
M12 x1
18
137,3 80
M12 x1
1 M12 x1
43,6
M12 x1
LED
43,6
www.ifm.com
M12 x1
107
FE
4,5
M12 x1
203
M12 x1
25
85 20 35 9,6
2
31 45
0 1
66
23
82,5 80 40
1
33
35 9,6
26
45 120
5,3 7
31 45
66
24
LED
85
27
0 1 2
35,5
104
45 91 108
91,2
120
4 0 1
50
91 108
5,3
105,9
www.ifm.com
204
40
50
82,6
35,5
102
32
108
35,5
LEDs
93,5
M12 x1
1: Addressing socket
58,5
UU U
29
25
105
66,5
80
33
108 35,5
105
1
207
56
30
80
72
120
45,5 80
34
24 49,4 56 LED 1 2 55 53,5 17 41
111
70
5,5
M12x1
4,2
M12 x1
17
4,5
31
80
2
25
M12 x1 LED
www.ifm.com
72
56
105
205
M12 x1
65 80
7,5
65
17
LED
www.ifm.com
206
207
208
Selection chart
Multicode reader Accessories Scale drawings - CAD download: www.ifm.com
Page
211 211 211
www.ifm.com
209
Orientation-independent identification of 1D and 2D codes. Very small housing for flexible use. Simple, menu-guided parameter setting. Integrated lighting. High reading reliability even with soiled / damaged codes.
Multicode reader The ECC200 Data Matrix code is becoming more and more popular throughout industry alongside familiar barcodes. In this code lots of information can be stored in a very small space and read using the compact multicode reader. The industrially compatible mounting and wiring technology as well as the standardised process interfaces RS-232, Ethernet TCP/IP and EtherNet/IP enable easy and quick integration into the industrial control technology. Applications can be found in many different industrial areas: from the product tracking and production control to product identification. Orientation-independent reading Independent of the orientation and the number of codes, the high-performance algorithms automatically decode 1D or 2D codes. The optimisation parameters of the codes and functions of the multicode reader undergo continuous development and are made available as upgrades. Code comparison in the sensor Complex application programming is no longer necessary due to adjustable, selective code identification and comparison in the sensor. This allows a defined number of characters within a code to be checked and signalled via the switching output if they match. Reliable identification of 1D and 2D codes In addition to the automatic exposure setting, manual adjustment is also possible. So optimum results are achieved even with highly reflective metal surfaces. For evaluation of the code quality parameter, ISO / IEC 15415 or 16022 can be used. The Data Matrix code The Data Matrix code is a two-dimensional code containing much more information with the same structure size than codes such as bar codes or stacked codes. Several thousand characters can be stored in one code. An important feature of the Data Matrix code is the high reading reliability. If the code is soiled or damaged, the intelligent system can completely recompose the information from different segments again. The Data Matrix code can be structured differently and is variable in shape and size. The size can cover 1 x 1 mm to 100 x 100 mm.
Lose no time: the multicode reader can be configured in a few minutes and is then ready for use. Only five guided steps are necessary for the multicode reader to be ready for operation.
Whether printed on paper, graved by laser or dot-peened on metal: reliable detection of the code, independent of the sensor orientation.
www.ifm.com
210
Multicode reader
Type Dimensions Max. field of view size [mm] Type of light LED Motion speed int. / ext. lighting [m/s] Process interface Drawing no. Order no.
[mm]
Accessories
Type Description Order no.
Operating software O2I for multicode reader Create and manage application-specific configurations Monitor mode for set-up and service Service reports for statistical evaluations
E2I200
Plastic protective pane for the food industry O2D / O2I Housing materials: housing: diecast zinc black / lens: PMMA
E21166
Mounting set O2D, O2M, O2I Clamp mounting rod mounting 12 mm Housing materials: fixture: stainless steel / clamp: stainless steel
E2D110
mounting rod 14 / M12 Length: 130 mm straight Housing materials: stainless steel 316Ti / 1.4571
E20939
mounting rod 14 / M12 Length: 200 mm angled Housing materials: stainless steel 316Ti / 1.4571
E20941
57 60
45
24,5
80
4,3
20,5
9,5 7
19,7 33 44
M12x1 M12x1
www.ifm.com
19
211
212
RF-identification systems
Selection chart
RFID systems Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com
Page
215 215 215 216
www.ifm.com
213
RF-identification systems
RFID write and read heads and a selection of tags. Industrial ident system using the 125 kHz range. Up to 31 compact read / write heads per evaluation module. Read or write up to 15 bits within 20 milliseconds. Data interface to high end systems; Profibus, DeviceNet, ethernet and others.
RF-identification systems The constant increase of the degree of automation in modern production plants is increasingly supported by identification systems. Their tasks include for example the control or release of production steps or the assignment of information about each product. The RF identification system (Radio Frequency Identification System) from ifm electronic is a compact and easy alternative for applications in which for example optical identification is not possible due to the ambient conditions. It is also the first RF identification system for AS-interface worldwide. It allows reading and writing of code carriers (ID tags), benefiting from the advantages of AS-interface. It can be integrated into existing AS-I networks without problem and is immediately ready for operation. For reading, the RF identification system uses the AS-i analogue protocol 7.4 for data transfer. Special software modules are not required. Up to 31 read/write heads can be connected to one AS-i master. The read/write head stores transmission errors which can be retrieved for a targeted fault analysis. Antenna, electronics and AS-interface are integrated in a compact housing. The voltage is supplied via the AS-i network via a rotatable M12 connector. No additional operating voltage required. The ID TAG (transponder) provides flexible mounting options for workpiece carriers, tanks, etc., ... Operating principle The RFID system from ifm electronic generates a 125 kHz electromagnetic field for reading and writing of data. The electromagnetic field emitted by the antenna induces voltage in the passive ID tag (transformer principle). This activates the ID tag (transponder) which returns its code. Processing of the code and transmission to the AS-interface are carried out in the read / write head. Advantages: reliable data transmission in dynamic reading processes and ID tags for each application.
The read / write heads exchange data with the passive ID tags at a maximum distance of 20 mm. The ID tag provides flexibility for different types of mounting.
The ID tag is mounted to tanks or workpiece carriers in the tag fixture or alternatively by direct mounting using an M5 grub screw.
www.ifm.com
214
RF-identification systems
RFID systems
Type Dimensions Travel speed read / write [m/s] Process interface Wiring diagram no. Drawing no. Order no.
[mm]
M12 connector
55 x 24 x 41 read: 0.5 (distance to the ID tag 15 mm) write: only static AS-i 1 1 DTA100
92 x 80 x 40
AS-i
DTA300
Accessories
Type Description Order no.
ID tag ID-TAG/TRIANGEL HOUSING/01 with ID tag E80301 Housing materials: PBT orange (RAL 2003) / PA black (RAL 9005)
E80302
E80317
E80320
E21088
Wiring diagrams
1
AS-i+
AS-i
www.ifm.com
215
RF-identification systems
2
112 92 40 20
70
5,5
M12 x1
4,2
M12 x1
17
4,5
65 80
7,5
65
17
LED
2 5
www.ifm.com
216
RF-identification systems
217
218
Power supplies
Selection chart
Switched-mode power supplies Scale drawings - CAD download: www.ifm.com
Page
221 221 - 222
www.ifm.com
219
Power supplies
Range of regulated 24 V DC switched mode power supplies. Both 1-ph and 3-ph primary side available. From 1 amp up to 40 amp load. Robust metal housing, easy and safe DIN rail mounting. Robust metal housings with 35 mm rail mounting.
Power supplies They may be unglamorous and unobtrusive, but without them it would not be possible to operate an electronic system. Power supplies are essential. ifm offers lowcost transformer power supplies but also powerful switched-mode power supplies for different applications. Transformer power supplies Transformer power supplies provide a low voltage, normally 24 V DC. A transformer according to DIN 0551 ensures a safe electrical separation from mains voltage and low voltage. The output voltage can be regulated ( 5 %) or smoothed by means of capacitors. The different designs and output powers allow adaptation to diverse operating conditions. Switched-mode power supplies Primary switched-mode power supplies are a compact and economical solution to supply sensors and actuators. As opposed to conventional transformer power supplies with regulated output voltage they need no heavy transformers so that there are fewer iron and copper losses. They are therefore distinguished by a very high degree of efficiency of up to 92 %. Due to the operating principle by means of high frequency transformers switched-mode power supplies are much smaller and lighter than transformer power supplies with identical power. Nevertheless they guarantee an electrical separation. Furthermore, they offer a wide input voltage range as standard for worldwide use. Power reserves Mains fluctuations up to 15 % and mains interference are compensated for. Even mains voltage dips of a few milliseconds are compensated for, the output voltage is completely maintained. An active inrush current limitation reduces the inrush current by means of a fixed resistor which is bridged after start up. The outputs are protected against short circuits and overload. Special output characteristics allow a current which can be up to 1.7 higher than the nominal current without switch-off with the voltage being reduced at the same time. The dimensioning of the components allows a 20 to 25 % higher output current for a short time. This power reserve is provided by all power supplies as from 2.5 A for a period of one minute. At an operating temperature of up to 45 C this power is available continuously.
Suitable for the application: ifm provides power supplies in different power classes.
www.ifm.com
220
Power supplies
DN2013
20
24...28 DC (2%)
230 AC
91
DN2014
24...28 DC (2%)
3 x 400...500 AC
89
DN2032
10
24...28 DC (2%)
3 x 400...500 AC
90
DN2033
30 40
3 x 400...500 AC 3 x 400...500 AC
93 92.5
5 6
DN2036 DN2035
1.25 2.5
24...28 24...28
84 88
7 7
DN1030 DN1031
2.5 5
24...28 24...28
87.1 88.9
8 8
DN3011 DN3012
2
220
124 131
LED
107 4
227 LED
89
107 4
www.ifm.com
124 131
221
Power supplies
6
275
124 131
LED
282 LED 89
4
90
1 2 3
131 124 107 4
4 5 6
110 121
122
1: LED red, 2: reset push button, 3: jumper overload performance, 4: jumper single/parallel operation, 5: with pot., 6: LED green 5
240
90
LED
45
100
1: with pot. 8
124 131
247 LED 89
LEDs 1
129 136
50
136 144
1: with pot.
107 4
www.ifm.com
222
124 131
Power supplies
223
224
Connection technology
Selection chart
Sockets for industrial applications Sockets for industrial applications Cable plugs for industrial applications Connectors for oils and coolants Connectors for oils and coolants Connectors for electromagnetric fields Connectors for hygienic and wet areas Connectors for hazardous areas Scale drawings - CAD download: www.ifm.com
Page
227 227 - 228 228 229 229 229 230 - 231 231 231 - 234
www.ifm.com
225
Connection technology
Complete product range: sockets, plugs, jumper cables, splitter boxes. Various cable materials for different applications. High-quality materials for maximum reliability. ecolink series with innovative quality features. Integrated LEDs for easy diagnosis.
Connection technology With a wide variety of different sensor designs ifm electronic offers a wide range of high quality connectors. The choice of types covers common M8, M12, M18 types through to valve plugs. The ecolink connectors (order no. EVxxxx) offer additional quality features. ecolink - a new dimension in connection technology Due to the special installation of a mechanical end stop the O-ring is always correctly compressed and so permanently maintains its sealing function. The connector remains securely positioned on the unit even in case of extreme vibration and impacts. Novel design and a transparent black housing ensure that even in bright lighting conditions the LEDs are more clearly visible than with the clear transparent versions. For industrial applications: High-quality materials suited to the requirements in industrial environments. Largely resistant to oils and greases. For hygienic and wet areas: PVC housing and cable, gold-plated contacts and high-grade stainless steel nuts are the optimum choice for long life. For oils and coolants: With PUR housings, cable with full PUR sheaths, Viton seals and gold contacts, these products set new standards for the harsh operating conditions of the machine tool industry. For hazardous areas Connection technology for ATEX categories 2D, 3D and 3G. With the EC type examination certificate for components from DEKRA EXAM the connection technology meets the strictest requirements. For welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited for drag chains and torsional movements. For sensors in robust applications: The saw tooth contoured vibration protection secures against strong shocks and vibrations. The high protection rating, wide temperature range and high-quality housing materials (high-grade stainless steel, TPU) ensure permanent safe connection in harsh environments. www.ifm.com
Maximum operational reliability due to the new vibration protection with end stop. Black, transparent housing for optimum LED visibility.
226
Connection technology
www.ifm.com
227
Connection technology
Type
Cable
Wire specification
U [V]
Ta [C]
Protection
LEDs
Drawing no.
Order no.
3 x AWG22, 5.2 mm
TPU / brass
250 AC 300 DC
-25...90
IP67
14
E10191
www.ifm.com
228
Connection technology
PA
10...30 DC
-25...80
IP67
green / 6 x yellow
20
EBC031
PA
10...30 DC
-25...80
IP67
green / 8 x yellow
21
EBC035
www.ifm.com
229
Connection technology
www.ifm.com
230
Connection technology
Type
Cable
Wire specification
U [V]
Ta [C]
Protection
LEDs
Drawing no.
Order no.
10
31 M8x1
10 25,5
19
M8x1
LED
10 25,5
19
10 9
31
M8x1
M8x1
www.ifm.com
231
Connection technology
15 10 25,5 19
28
M8x1
9 M12 x1 10,5
12
20 20 35 45
30
18
38
M16x1
M12 x1
13
49
15
27
18
46 39
M12 x1
G1 2 10,5
14
15,5
26,5
15 42
M12x1
36,5
14
G1 2
15
15 15,5 14
10,5
27
M12x1
45
12
"-20UNF 10,5
10
16
20
39
42
15
31 18
M12 x1
43
M12 x1 15
www.ifm.com
232
Connection technology
34
PWR
152
73
18
M12 x1
M12x1
15,5
14
4,7
28,5 39
7,5
19
22
22 18
M12x1
49,5
15,5
4,5
26,5
60
36,5
M12x1
3 LED
14
34
PWR 3 4
118,2
M12x1
73
23
4,7
4,5
10
28,5 39
7,5
18
22 18
M8 x1
28
20
24
60
31
5 6
10
34
M8 x1
PWR 3 4
125
M12x1
73
25
4,7
28,5 39
7,5
4,5
18 10
22 18
M8 x1
28
www.ifm.com
233
Connection technology
26,5 15,5 14 14 15,5 45 14 M12 x1 15,5 49 L 45 15,5 15,5 26,5 M12x1 36,5 14 31 36,5 14 10
M12x1 9
M8 x1
27
32
M12x1
28
36,5
33
14 15,5
M12 x1 15,5
M12 x1
45
29
34
26,5
M12x1
36,5
LED
14
30
M12 x1 15,5
14
14
M12 x1 15,5
49
45
www.ifm.com
234
Connection technology
235
Argentina
ifm electronic s.r.l. Manuela Senz 323 5 piso, oficina 3 C1107BPA - Puerto Madero Buenos Aires, Argentina Tel. (011) 5353-3436 Fax (011) 5353-3436 Interior 0810-345-3436 info.ar@ifm.com www.ifm.com/ar
Brazil
ifm electronic Ltda. Rua Eleonora Cintra, 140 Jardim Analia Franco 03337-000 So Paulo/SP Tel. +55-11-2672-1730 Fax +55-11-2673-3501 info.br@ifm.com www.ifm.com/br
Croatia
ifm electronic gmbh Wienerbergstr. 41 Gebude E A-1120 Wien Tel. +43 / 1 / 617 45 00 Fax +43 / 1 / 617 45 00 10 info.hr@ifm.com www.ifm.com/hr
France
ifm electronic Sige : Savoie Technolac BP226 73374 Le Bourget du Lac Agence commerciale : Immeuble Uranus 1-3 rue Jean Richepin 93192 NOISY LE GRAND CEDEX Tl: 0820 22 30 01 Fax: 0820 22 22 04 info.fr@ifm.com www.ifm.com/fr
Ireland
ifm electronic (Ireland) Ltd. No. 7, The Courtyard Kilcarbery Business Park New Nangor Road Clondalkin Dublin 22 Tel. +353 / 1 / 413 60 66 Fax +353 / 1 / 457 38 28 sales_ie@ifm.com www.ifm.com/ie
Bulgaria
ifm electronic eood ul. Slatinska Nr. 92 A, ap. 2/3 1574 SOFIA Tel. +359 2 807 59 69 Fax. +359 2 807 59 60 info.bg@ifm.com
Czech Republic
ifm electronic spol.s.r.o. U Kku 571 252 43 Prague Tel. +420 / 2 / 67 990 211 Fax +420 / 2 / 67 750 180 info.cz@ifm.com www.ifm.com/cz
Australia
ifm efector pty ltd. P.O. Box 4084 Suite 3, 745 Springvale Road Mulgrave VIC 3170 Tel. 1300 365 088 Fax 1300 365 070 sales.au@ifm.com www.ifmefector.com.au
Israel
Astragal Ltd. 3, Hashikma Str. Azur 58001 P.O. Box 99 Azur 58190 Tel. +972 / 3 / 5 59 16 60 Fax +972 / 3 / 5 59 23 40 astragal@astragal.co.il www.astragal.co.il
Germany
ifm electronic gmbh Friedrichstr. 1 45128 Essen Tel. +49 201 24 22 0 Fax +49 201 24 22 12 00 info@ifm.com www.ifm.com/de
Canada
ifm efector Canada Inc. 700 Dorval Drive/Corporate Centre Oakville; L6K3V3 Ontario Tel. +1-800-441-8246 Fax +1-800-329-0436 info@ifmefector.ca www.ifmefector.ca
Denmark
ifm electronic a/s Ringager 4A, 1.sal tv. 2605 Brndby Tel. +45 70 20 11 08 Fax +45 70 20 11 09 info.dk@ifm.com www.ifm.com/dk
Austria
ifm electronic gmbh Wienerbergstrae 41 Gebude E 1120 Vienna Tel. +43 / 1 / 617 45 00 Fax +43 / 1 / 617 45 00 10 info.at@ifm.com www.ifm.com/at
Italy Greece
ifm electronic monoprosopi E.P.E. 27, Andrea Papandreou Street 15125 Amaroussi Greece Tel +30 210 61 800 90 Fax +30 210 61 994 00 info.gr@ifm.com www.ifm.com/gr ifm electronic Centro Direzionale Colleoni Palazzo Andromeda 2 Via Paracelo n 18 20041 Agrate Brianza (Milano) Tel. +39 / 039 68 99 982 Fax +39 / 039 68 99 995 info.it@ifm.com www.ifm.com/it
Chile
Electronica Industrial Schdler y Cia. Ltda. Av. Antonio Varas 1871 Providencia 6641545 Santiago Tel. +56 / 2 / 274 74 30 Fax +56 / 2 / 204 93 38 info@schadler.com www.schadler.com
Dominican Republic
WECH AUTOCONTROLES S. A. Ave. Romulo Betancourt 2158 Edificio Wech Urb. Renacimiento Santo Domingo Dominican Republic Tel.: + 1 809-531-0550 Fax: + 1 809-531-9175 wech@verizon.net.do www.wechautocontroles.com .do
Bangladesh
Sensotec Automation Red Crescent Chamber 87, Motijheel Commercial Area Dhaka 1000 Bangladesh Tel. +880 171 546 890 sensotec@agni.com
Honduras
R y D INDUSTRIAL Bo. Paz Barahona 11 Ave. 14 y 15 Calle S.O. #142 San Pedro Sula Telefon:+504 5503703 Telefax:+504 5501108 ramonmorales@sulanet.net
Japan
efector co. ltd. Chiba Higashi Techno Green Park 2-9-20 Okayamadai Togane-shi, Chiba 283-0826 Tel. +81 / 475 50 3003 Fax +81 / 475 50 3013 ifm-j@efector.co.jp www.ifm.com/jp
China
ifm electronic (Shanghai) Co., Ltd Building 15, No 912 Bi Bo Road, Pu Dong District Shanghai 201210, China Tel. +86-21-50278559 Fax +86-21-50278669 Fax +86-21-50800213 info.cn@ifm.com www.ifm.com/cn ifm electronic (HK) Ltd Unit 2106, 21/F, Tower 2, Metroplaza No. 223 Hing Fong Road, Kwai Chung, N.T., Hong Kong. Telefon: +852 3528-0462 Fax: +852 3697-0222 info.hk@ifm.com www.ifm.com/hk ifm electronic (Taiwan) Limited 2C, Bao-Cheng Enterprise Tower, No. 6 Mincyuan Second Road, Cianjhen District, Kaohsiung City, Postal Code 806, Taiwan, R.O.C. Tel.: +886-7-335-7778 Fax: +886-7-335-6878 info.tw@ifm.com www.ifm.com/tw
Belarus
DEPOSIT INVEST Joint-Stock Company Block 2, 27 Zheleznodorovhnaya street 220089 Minsk Republic of Belarus Tel. +375-17-270 75 06 Fax +375-17-270 75 07 george_ozerov@infonet.by
Ecuador
INSELEC CIA. LTDA. Av. de los Arupos E1-202 y Pan. Norte- Km 5 Quito Tel. +593 2 28074- 76 - 78 Fax +593 2 2807475 inselec@inselec.com.ec www.inselec.com.ec
Hungary
ifm electronic kft. Kzp u. 16. II.em. 208. iroda H-9024 Gyr Tel. +36-96 / 518-397 Fax +36-96 / 518-398 info.hu@ifm.com www.ifm.com/hu
Jordan
Al Mashreqan Trading Supplies P.O.Box.851054 11185 Swaifieh Amman - Jordan. Tel. +962 6 581 8841 Fax +962 6 581 8892 info@mashreqan.com
Egypt
Egyptian Establishment for Electromechanical Supplies Mr. Ahmed Gouda 27 Al-Salam Street Al Arezona, Al Haram Road Giza 12111, Cairo Tel. +20 / 2 / 586 49 49 Fax +20 / 2 / 586 49 49 Mobile +20 10 10 61 791 ahgouda@hotmail.com
India
ifm electronic India Pvt. Ltd. Plot No. P-39/1 MIDC Gokul Shirgaon Kolhapur 416234 Maharashtra State, India Tel. +91 / 231 / 267 27 70 Fax +91 / 231 / 267 23 88 info@ifm-electronic.in www.ifm.com/in
Korea
ifm electronic Ltd. 2F Hyundai Liberty House #201 Hannam-Dong 258, Yongsan-Gu, Seoul, Korea Tel +82 2-790-5610 Fax +82 2-790-5613 info.kr@ifm.com www.ifm.com/kr
Bolivia
BAVARIA S.R.L. lvaro Baptista Vargas Zona Morocollo, Urb. Santos Pariamo C. Mario Diaz de medina (26-A), Nr. 32 La Paz - Bolivia Tel.: 00-591-2-277 13 78 Mobile: 00-591-720-47 442 alvarobaptista@bavaria.bo www.bavaria.bo
Estonia
Pesmel Estonia LTD Segu 4 76505 Saue Estonia Tel.: +372 674 73 30 Fax: +372 674 73 31 pesmel@pesmel.ee www.pesmel.ee
Indonesia
PT Indoserako Sejahtera Jl. P. Jayakarta 121 No. 59 10730 Jakarta Pusat Tel. +62 / 21 6 24 8923 Fax +62 / 21 6 24 8922 iso297@dnet.net.id
Latvia
EC Systems Katlakalna Str. 4A 1073 Riga Latvia Tel.: +371 724 1231 Fax: +371 724 8478 alnis@ecsystems.lv www.ecsystems.lv
Columbia
SENSOMATIC Y CIA LTDA. CALLE 1 C 25a - 50 BOGOTA D.C. COLOMBIA Tel. +57 313 430 2264 and +57 1 407 96 96 info@sensomatic-ltda.com http://www.sensomaticltda.com
Finland
ifm electronic oy Vaakatie 5 00440 Helsinki Tel. +358 / 9 / 751 777 00 Fax +358 / 9 / 751 777 10 info.fi@ifm.com www.ifm.com/fi
www.ifm.com
236
Lebanon
Middle East Development Co. SAL (MEDEVCO) Medevco Building Jeita Main Road Jeita - Kesrouan Lebanon Mail address : P.O.Box 67 Jounieh Lebanon Tel + 961-9-233550 Fax + 961-9-233554 info@medevco-lebanon.com
Nigeria
Automated Process Ltd 3rd Floor, 32 Lagos Abeokuta Expressway Near Cement Bus Stop Dopemu, Agege Lagos State, Nigeria Tel. + 234 / 01 / 4729 967 Fax + 234 /01 / 4925 865 sales@automated-process.com www.automated-process.com
Portugal
ifm electronic Sucursal em Portugal Avenida da Republica 2503 4430-208 Vila Nova de Gaia Tel. +351 / 22 / 37 17 108 Fax +351 / 22 / 37 17 110 info.pt@ifm.com www.ifm.com/pt
Spain
ifm electronic s.l. Edificio Prima Muntadas A Parc Mas Blau C/Bergued 1 08820 El Prat de Llobregat Tel. +34 / 93 / 479 30 80 Fax +34 / 93 / 479 30 86 info.es@ifm.com www.ifm.com/es
Romania
ifm electronic s.r.l. Str. Cristian Nr. 5 550073 Sibiu Tel.: 0040 269 224550 Fax: 0040 269 224766 info.ro@ifm.com
Sweden
ifm electronic ab Hallavgen 10 512 60 verlida Office Gothenburg: Drakegatan 6 41250 Gothenburg Tel. +46 / 325 / 66 15 00 Tel. +46 / 325 / 66 15 50 Fax +46 / 325 / 66 15 90 info.se@ifm.com www.ifm.com/se
Norway
Siv.Ing. J.F.Knudtzen AS Billingstadsletta 97 1396 Billingstad Postboks 160 1378 Nesbru Tel. +47 / 66 98 33 50 Fax +47 / 66 98 09 55 firmapost@jfknudtzen.no www.jfknudtzen.no
Lithuania
Elinta UAB Terminalo g. 3, Biruliki k., Karmlavos sen. LT-54469 Kauno raj. (Kauno LEZ) Lithuania Tel.: +370 37 351 999 Fax: +370 37 452 780 sales@elinta.lt www.elintosprekyba.lt
Russia
ifm electronic Ibragimova, 31, k.50 office 607 105318 Moscow Tel.: +7 (495) 921-44-14 Fax: +7 (495) 651-82-97 info.ru@ifm.com www.ifm.com/ru
Oman
Technical Engineering Company LLC. P.O.Box. 59 Madinat Al Sultan Qaboos Postal Code 115 Sultanate of Oman Tel + 968 24503593 Fax + 968 24503573 tecoman@omantel.net.om
Switzerland
ifm electronic ag Altgraben 27 4624 Hrkingen Tel. +41 / 62 / 388 80 30 Fax +41 / 62 / 388 80 39 info.ch@ifm.com www.ifm.com/ch
United Kingdom
ifm electronic Ltd. efector House Kingsway Business Park Oldfield Road Hampton Middlesex TW12 2HD Tel. +44 / 20 / 8213 0000 Fax +44 / 20 / 8213 0001 enquiry_gb@ifm.com www.ifm.com/uk
Malaysia
ifm electronic Pte. Ltd Malaysian Branch Office No. 2-4-2, Fourth Floor Tower 2 @ PFCC, Jalan Puteri 1/2, Bandar Puteri Puchong, 47100 Puchong, Selangor. Tel. +60 / 3 / 8063 9522 Fax +60 / 3 / 8063 9524 sales_my@ifm.com ifm electronic Asia Regional Office No. 21, Jalan Kemunting, Taman Kebun The 80250 Johor Bahru Johor, West Malaysia Tel. +60 / 7 / 332 5022 Fax +60 / 7 / 332 1577 sales_my@ifm.com
Saudi Arabia
Noor Al-Shomoe for Electric & Maintenance King Khalid Street, Cross 5 P.O. Box 2571 Al-Khobar 31952 Kingdom of Saudi Arabia Tel. +9 663 864 49 58 Fax +9 663 894 63 41 h.o.info@nooralshomoe.com
Syria
I.E.C. Industrial Engineering Center P.O. Box 15 Sehnaya, Damascus Syria Tel. + 963 11 532 13 19 Fax. + 963 11 442 12 27 info@iec-automation.com
Pakistan
AB Automation Shop No.2. Rubab Chamber M.A. Jinnah Road Off Sarai Road Karachi Tel. +92 / 21 / 2412 278 Fax +92 / 21 / 2422 277 abauto@cyber.net.pk
USA
efector inc. 805 Springdale Drive Exton, PA 19341 Tel. +1 / 610 524 2000 Fax +1 / 610 524 2010 info@ifmefector.com www.ifmefector.com
Singapore
ifm electronic Pte. Ltd. 25, Intern. Business Park #03-104 German Center 609 916 Singapore Tel. +65 / 6 / 5 62 86 61 Fax +65 / 6 / 5 62 86 60 sales_sg@ifm.com www.ifm.com/sg
Thailand
Sang Chai Meter Co., Ltd. 694/16-19 Phaholyothin Road Samsen Nai, Phayathai Bangkok 10400 Tel. +66 / 2 / 616 8051 Fax +66 / 2 / 616 8050 scmth@ksc.th.com
Peru
dekatec s.a.c. Los Calderos 188 Urb. Vulcano, Ate Lima / Peru Tel. +511 / 348 0293 Tel. +511 / 348 0458 Tel. +511 / 348 2269 Fax +511 / 349 0110 dkleffmann@dekatec.com.pe www.dekatec.com.pe
Venezuela
Petrobornas, C.A. C.C. Los Pinos - Local E Av. Principal de la UD 304 (8015) - Puerto Ordaz - Edo. Bolivar Venezuela Tel. +58 286 994 3406 Tel. +58 416 686 5036 Fax +58 286 994 5249 info@petrobornas.net www.petrobornas.net
Mexico
ifm efector S. de R.L. de C.V. Anillo Perifrico, 1816-1 Col. Hacienda San Jernimo Monterrey, N.L. Mexico 64630 Tel. +52-81-8040-3535 Fax +52-81-8040-2343 www.ifmefector.mx
Slovakia
ifm electronic spol. s.r.o. Rybnicna 40 831 06 Bratislava Tel. +421 / 2 / 44 87 23 29 Fax +421 / 2 / 44 64 60 42 info.sk@ifm.com www.ifm.com/sk
Turkey
ifm electronic Elektrikli ve Elektronik Aletler th.hr.Paz.Tic.Ltd.ti. Merkez Mah. Nadide Sok. Anttepe Sitesi No:28 34381 ili / stanbul Tel. +90 / 212 / 210 5080 Fax +90 / 212 / 221 7159 info.tr@ifm.com www.ifm.com/tr
Philippines
Gram Industrial, Inc. Unit 410 Common Goal Tower Finance cor. Industry St., Madrigal Business Park, Ayala Alabang, Muntinlupa City 1770 Philipines Tel. (+63) 2 850-2218 Fax (+63) 2 850-8496 efector@gram.com.ph
Vietnam
Thien Viet Electrical Service and Trading Co., Ltd. 784 Dien Bien Phu Str. Ward 11, Dist. 10 Ho-Chi-Minh-City, Viet Nam Tel. +84 / 8 / 830 9916 Fax +84 / 8 / 830 9915 thivicoltd@hcm.vnn.vn
Netherlands
ifm electronic b.v. Deventerweg 1 E 3843 GA Harderwijk Tel. +31 / 341 438 438 Fax +31 / 341 438 430 info.nl@ifm.com www.ifm.com/nl
South Africa
ifm electronic (pty) Ltd Shorrok House Route 21 Corporate Park Nellmapius Drive, Irene Ext. 30, Centurion 0157, Pretoria Postnet Suite 279 Private bag X8 Elardus Park 0047 Tel. +27 (0) 861 IFM RSA / 436 772 Fax +27(0)12 450 0322 info.za@ifm.com www.ifm.com/za
Ukraina
ifm electronic Mariny Raskovoj 11 02660 Kiev Ukraine Tel. +380 44 501 8543 Fax +380 44 501 8543 info.ua@ifm.com www.ifm.com/ua
New Zealand
ifm efector pty ltd. Unit B, 20 Cain Road Penrose, Auckland Tel. +64 / 95 79 69 91 Fax +64 / 95 79 92 82 sales.nz@ifm.com www.ifm.com/nz
Poland
ifm electronic Sp.z o.o. ul. Kosciuszki 175 PL 40-524 Katowice Tel. +48 / 32 / 60 87 454 Fax +48 / 32 / 60 87 455 info.pl@ifm.com www.ifm.com/pl
www.ifm.com
237
www.ifm.com