You are on page 1of 47

CONNECTION DESIGN STANDARD

DOC NO: CDS-1

CONNECTION DESIGN STANDARDS


DOCUMENT NO: CDS-1 SECOND EDITION DATE: DECEMBER 9, 2005

CONNECTION DESIGN STANDARD

DOC NO: CDS-1

TABLE OF CONTENTS Section 1 2 3 4 Description Connection Components Allowable Loads Connection Types Shear Connections Double Clip-Angle Connections Single-Plate Connections Seated Beam Connections Beam Copes and Cope Reinforcement Figures 4.1 thru 4.27 Moment Connections Directly welded flanges Flange plate connection Figures 5.1 thru 5.6 Truss and Vertical Bracing Connection Single Brace Connections Double Brace Connections Chevron Bracing Connections Brace connection at column base X-brace connection Figures 6.1 thru 6.26 Horizontal Bracing Connection Shear-tab Connections Clip-Angle Connections Figures 7.1 thru 7.6 Splices Connection Capacity Tables Calculation Summary Table Templates Design Software and Worksheets Page No 1-1 thru 1-3 2-1 thru 2-8 3-1 thru 3-2 4-1 thru 4-50 Release Date

5-1 thru 5-7 8/12/05 6-1 thru 6-27

7-1 thru 7-7

8 Appendix A Appendix B Appendix C

8-1 thru 8-5 A-1 thru A-7 B-1 thru B-36 C-1 thru C-33

12/9/05

Page i

CONNECTION DESIGN STANDARD

DOC NO: CDS-1

REFERENCES AISC Manual of Steel Construction, Allowable Stress Design, 9th Edition, Vol I AISC Manual of Steel Construction, Allowable Stress Design, 9th Edition, Vol II Connections Steel Structures, Design and Behavior, by Charles G. Salmon and John E. Johnson. Design of Welded Structures, A Publication of The James F. Lincoln Arc Welding Foundation, June 1996 5. Hollow Structural Sections, Connections Manual, 1st Edition, 1997 1. 2. 3. 4.

Page ii

CONNECTION DESIGN STANDARD


1.0 Connection Components

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Members are connected by means of welding or bolting. Structural framing members of a building are usually connected using high strength bolts. The different components of a connection are as follows. A connection can have some or all of the components listed below. 1. Beam/Column Web 2. Beam/Column Flange 3. Bracing Member 4. Bolts, Nuts and Washers 5. Welds 6. Clip Angle (Used for connecting beam webs to column or other beams) 7. Gusset Plate (Typically the plates at the ends of bracing members) 8. Seat Plate 9. Seat Angle 10. Stiffener Plate Used to stiffen another plate against yielding, crippling, buckling, bending etc. Typically these are provided at column or beam webs, seat plate, etc. 11. Web Doubler Plate 12. Bearing Plate 13. Cap Plate Each of the components of the connection is checked for their limit states or failure modes. In addition to checking these components of the connection, local checks of the beam and column have to be done. The local checks include the beam copes, beam web, column web and column flange. The limit states for the connection components are as follows. 1. 2. 3. 4. 5. 6. 7. 8. Bolt failure due to shear or tension Weld failure Shear yielding (of beam web, of clip angle, etc) on gross area Shear rupture (of beam web, of clip angle, etc) on net area Tension yielding on gross area Tension rupture on effective net area Block shear (failure by shear and tension) of a block of material Bolt bearing (failure caused by excessive deformation at bolt holes or limited by proximity to a loaded edge) 9. Flexural yielding 10. Web yielding 11. Web crippling 12. Web buckling 13. Flange local bending 14. Prying action (causes additional tension in bolts based on the flexural stiffness of the connecting elements) 15. Whitmore section yielding or buckling of gusset plate at the ends of the bracing members

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

1.1 Material Requirement Bolts: The two common types of high-strength bolts are A325 and A490. A325 bolts are heat treated, while A490 bolts are heat treated and are of alloy steel. High-strength bolts are installed with a pre-tension. The pre-tension loads are given in Table J3.7 of AISC Manual, Specification Section J3. For structures that are not part of the main or critical load carrying system of a building, A307 carbonsteel bolts that are not heat-treated may be specified. High-strength bolts are pre-tensioned using one of the three methods, which are the calibrated wrench method, the turn-of-the-nut method and direct tension indicator method. The Specification for Structural Joints Using ASTM A325 or A490 Bolts provided in the AISC Manual discusses these methods in detail. The calibrated wrench method uses a manual or power wrench that stalls at a specified torque. The specified torque is calculated to obtain the desired tension in the bolt. The turn-of-the-nut method develops the pretension in the bolt by turning the nut through a specified rotation past the snug condition. The turn-of-the-nut method is more reliable than calibrated wrench method. The direct tension indicator method uses a hardened washer with protrusions on one face. When bolts are tensioned, the protrusions are flattened. The amount of gap remaining will indicate the amount of tension in the bolt. Recent development is the tension control (TC) bolts, which are torqued until the tip snaps off the threaded portion of the bolt indicating that the desired tension has been obtained. The TC bolts are covered by ASTM F1852. Washers: Shall be per ASTM F436. For A325 bolts, generally one hardened washer is provided under the turned element. For A490 bolts, hardened washer under the bolt head and the nut is provided. When long slotted holes are used in an outer ply, a plate washer at least 5/16 thick with a standard hole could be used. These washers shall be sized to cover the slot after installation. For A490 bolts a hardened washer 5/16 thick minimum shall be used. Nuts: For ASTM A325 bolts, nuts shall be per ASTM A563, grades C, C3, D, DH or DH3 or A194 grade 2H. For galvanized bolts, nuts shall be per ASTM A563 grade DH or A194 grade 2H. Nuts for A490 bolts shall be A563 grade DH or DH3 or A194 grade 2H.. Welding Material Common weld electrode used for joing carbon steel elements is the E70 weld electrode having a tensile strength of 70 ksi. E60 may also be specified but is not used extensively.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Table 1-1: Material Properties Connection Components (Commonly Specified) (Note 1) Component Beam/Column Members Brace/Truss Members Shapes/Plates/Misc Wide Flange Wide Flange Square or Rectangular HSS Wide Flange Wide Flange Angle Tee (Cut from W Shapes) Round HSS Square or Rectangular HSS to 1 dia 1 1/8 to 1 dia to 1 dia to 1 dia 1 1/8 dia Plate ASTM Designation A992 A36 A500 Grade B A992 A36 A36 A992 A36 A53 Type E, Grade B A500 Grade B A325 A325 A490 F1852 (TC bolts) F1852 (TC bolts) A307 A36 A572 Grade 50 A36 Min Yield Strength 50 ksi 36 ksi 46 ksi 50 ksi 36 ksi 36 ksi 50 ksi 36 ksi 35 ksi 46 ksi 92 ksi 81 ksi 92 ksi 81 ksi 36 ksi Min Tensile Strength 65 ksi 58 ksi 58 ksi 65 ksi 58 ksi 58 ksi 65 ksi 58 ksi 60 ksi 58 ksi 120 ksi 105 ksi 150 ksi 120 ksi 105 ksi 60 ksi 58 ksi AISC Manual Ref Page Pg. 1-7 Pg. 1-92 Pg. 1-7 Pg. 1-7 Pg. 1-7 Pg. 1-92 Pg. 1-92 Pg. 4-4

High-Strength Bolts

Common Bolts Gusset/Stiffener/B earing/Seat/Web Doubler/Cap Plates Clip/Seat/Claw Angles

Pg. 4-4 Pg. 1-7

Angle

36 ksi

58 ksi

Pg. 1-7

Note 1: For additional material properties not covered in the table, see the AISC Manual Reference pages.

CONNECTION DESIGN STANDARD


2.0 Allowable Loads for Bolts and Welds

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

2.1 Bolts The Allowable Loads for bolts in tension is given in Table I-A of AISC Manual, Vol I. The Allowable Loads for bolts in shear is given in Table I-D of AISC Manual, Vol I. When slipcritical bolts are used in a connection, the resistance to slip is provided by the clamping force across the faying surface. The resistance is calculated as the clamping force times a coefficient of friction. The coefficient of friction varies depending on the type of surface preparation and the coating specified for the steel. Generally, the design is based on a Class A surface. When steel is galvanized, the Class C friction coefficient can be used. The friction coefficient for various class of surface is provided in Specification for Structural Joints Using ASTM A325 or A490 Bolts. The allowable shear given in Table I-D is based on a Class A surface. These allowable can be revised (increased) if the faying surface is Class B or Class C. The Allowable Loads for bolts in bearing on different material thicknesses is given in Table I-E of AISC Manual, Vol I. Bolt allowables shall be reduced when using oversized or slotted holes. Short slotted holes can be used in any or all plies of the connection. Long slotted holes are generally provided in only one ply of the connection. In bearing-type connection, the bolts shall not be considered to share the load with the weld. However, in slip-critical connections, bolts and welds shall be considered to share the load. However, it is preferable to avoid such situations. Bolt and weld group subjected to shear load with an eccentricity can be designed using either elastic method or the ultimate strength method, also called the instantaneous center of rotation method. AISC Manual provides coefficients for both bolt and weld groups based on the instantaneous center of rotation method. These Tables are conservative for slip-critical bolts and when used for ASTM A490 bolts. When the eccentric shear load is at an angle to the vertical, AISC Manual provides a procedure for using the instantaneous center of rotation method. See Alternate Method 2, pgs. 4-59 thru 4-61 in the AISC Manual. In lieu of this alternate method, the elastic method can always be used. The load obtained by elastic method is about 10% less than what is obtained by the ultimate load method. However, when bolt groups do not conform to the pattern given in the AISC Tables XI through XVIII, the elastic method shall be used.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

2.1.a Elastic Method of Bolt Analysis for bolts subjected to loads in the plane of the connection Let the assumed plane of the connection be X and Y Loads: Px, Py and Mz Where Px = Load along X-direction Py = Load along Y-direction Mz = Torsional moment caused due to eccentricity of Px and Py load about the centroid of bolt group Number of bolts = n Determine the Moment of Inertia Ix and Iy Determine the Moment of Inertia Ix = y Where y is the distance of each bolt in the y-direction from the neutral axis.
2

x Determine the Moment of Inertia Iy = Where x is the distance of each bolt in the y-direction from the neutral axis.
2

Determine Polar Moment of Inertia Ip = Ix + Iy Let distance of the farthest bolt along X-Axis = Cx Let distance of the farthest bolt along Y-Axis = Cy Bolt Stress (X-Dir) = fx = ( Px n) + Mz * Cy Ip Bolt Stress (Y-Dir) = fy = ( Py n) + Mz * Cx Ip Resultant Bolt stress =
fr = fx 2 + fy 2

should be less than allowable bolt shear.

2.1. b Elastic Method of Bolt Analysis for bolts subjected to shear and tension due to bending Let the assumed plane of the connection be X and Y Loads: Py and Mx Where Py = Load along Y-direction Mx = Moment caused due to eccentricity of Py load about the X-axis Number of bolts = n Let distance of the farthest bolt along Y-Axis = Cy

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Bolt shear Stress (y-dir) = Bolt tensile Stress (z-dir) =

fy = ( Py n) fz = ( Mx Ix ) Cy

See Section 2.1.c for checking bolts subjected to tension and shear simultaneously. 2.1. c Bolts subjected to Tension and Shear When bolts are subjected to both tension and shear, the interaction of tension and shear stresses has to be performed. In calculating the applied tension, the applied tension shall be the sum of the external load and any tension resulting from prying action produced by deformation of connected parts. Prying action is discussed at the end of this section. For Slip-Critical Bolts The interaction of tension and shear is done only if there is a net direct tension on the joint. As discussed earlier, the slip-critical joints obtain their resistance through the clamping force across the faying surface. When a moment is applied across a faying surface that causes some portion to go into tension and some into compression, there is no change in the net clamping force across the joint. Hence, although some bolts in the joint may experience tension and others do not, the bolts under tension need not be evaluated for the tension load since there is no net tension on the joint. Therefore, when there is a net direct tension on the joint, The allowable bolt shear shall be reduced by the factor (1 ft Ab Tb ) Where ft is the average tensile stress on a bolt caused by direct tension load And Ab is the nominal tensile area of the bolt given in Table I-A and Tb is the bolt pretension as given in Table J3.7 of the AISC Specification For Bearing Type Bolts For bearing type bolts, whether the tension is caused through direct tension or through a moment, the interaction of tension and shear is done. For bearing type connections, the allowable tension stress is altered based on the equations provided in Table J3.3 for A325 and A490 bolts depending on whether threads are included in the shear plane or not. Prying Action Prying action is the deformation of the connected part, for example the clip angle of a shear connection subjected to tension or transfer loads, split-beam tee moment connection where the flanges of the tee deform and dig into the column causing extra tensile force in bolts or hanger type connections where the bending of the outstanding leg of angles or flanges of Tee cause prying forces.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Hence prying action involves not only the bolts but also the flange or angle thickness, bolt pitch and gage. AISC, ASD Manual, Part 4 provides the Analysis and Design Methodology to determine the prying force, the thickness of the flange or angle leg required to develop the full tensile capacity without additional prying loads, the thickness of the angle or flange required to develop the moment due to prying. Note that shear connections subjected to axial loads usually require much thicker angles to resist the moment developed in the connection angle. Hence, shear connections subjected to axial loads shall be evaluated on a case by case basis. 2.2 Welds Welding is a process for joining similar metals. Welding joins metals by melting and/or fusing the base metals being joined with or without a filler metal. Welding is done using localized heat input. Most welding involves ferrous-based metals such as steel and stainless steel. Weld joints are usually stronger or as strong as the base metals being joined. Most of the commonly used welding techniques employ an electric arc to generate the heat necessary for welding. These processes are covered under the general term Arc Welding. The different arc welding techniques are the following. 1. 2. 3. 4. Shielded Metal Arc Welding (SMAW) Submerged Arc Welding (SAW) Gas Metal Arc Welding (GMAW) Flux Cored Arc Welding (FCAW)

Another unique arc welding technique is Stud Welding. In this process the stud itself acts as the electrode. The stud is placed in a stud gun that contains a ceramic ferrule, which acts as the shield for the weld. The gun is placed in position and an electric arc is created to melt the end of the stud. The molten metal is contained within a ceramic ferrule. The stud is then driven into the molten metal by the gun creating a full penetration weld across the shank along with a small fillet around the stud. Welds shall be designed per the requirements of AWS D1.1 - Structural Welding Code Steel For Carbon steels used in the design, the E70XX electrode is the matching electrode commonly used. This has similar or greater mechanical properties than the connected materials. Allowable Stress for E70XX electrode and effective throat of welds shall be as provided in Table 2-1.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Table 2-1: Effective Throat of Weld and Allowable Stress of E70XX Weld Weld Type Effective Throat Stress Type Allowable Stress Fillet Weld Shortest distance Shear on effective 0.3 x 70 ksi from root of joint to area the face of the weld, Tension or Same as base Typically equal to Compression parallel metal 0.707 x weld size to axis of weld Complete1) Thickness of the Tension/compression Same as base Penetration thinner part joined normal to effective metal Groove Weld 2) For Flare groove area weld, 5/16 R where R Tension/compression Same as base = 2t, t being the parallel to axis of the metal thickness of the weld material with the Shear on effective 0.3 x 70 ksi rounded corner area PartialPenetration Groove Weld 1) Depth of chamfer (for J or U joint or for bevel >= 60 deg) 2) For bevel < 60 deg and >=45 deg it is depth of chamfer 1/8 Shear parallel to axis of weld Tension normal to effective area Compression to effective area Tension/compression parallel to axis of the weld 0.3 x 70 ksi 0.3 x 70 ksi Same as base metal Same as base metal

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

2.2.a

Weld Analysis and Design

Weld group subjected to shear load with an eccentricity can be designed using either elastic method or the ultimate strength method, also called the instantaneous center of rotation method. AISC Manual, Tables XIX through XXVI provide coefficients for weld groups based on the instantaneous center of rotation method. When the eccentric shear load is at an angle to the vertical, AISC Manual provides a procedure for using the instantaneous center of rotation method. See Alternate Method 2, pgs. 4-73 thru 4-74 in the AISC Manual. In lieu of this alternate method, the elastic method can always be used. The load obtained by elastic method is about 5% less than what is obtained by the ultimate load method. However, when bolt groups do not conform to the pattern given in the AISC Tables XI through XVIII, the elastic method shall be used. 2.2.b Elastic Method of Weld Analysis for welds subjected to shear, torsion and moment Welds can be subjected to a combination of shear, torsion and bending moment loads. To investigate the weld, the following steps shall be taken. 1. Assume a unit thickness of weld and draw the effective cross-section of the weld group. 2. Establish a coordinate system and determine the centroid of weld group. Calculate the properties of weld treated as lines. Properties of most commonly used weld groups are provided in Table 2-2. For example: Let the assumed plane of the connection be X and Y Properties required are Centroid Length Moment of Inertia Ix Moment of Inertia Iy Polar Moment of Inertia Ip Distance of the extreme weld point to the weld centroid along x-axis (cx) Distance of the extreme weld point to the weld centroid along y-axis (cy) 3. Determine the forces on the weld group. Loads: Px, Py, Pz, Mx, My and Mz Where Px and Py = Shear Loads Pz = tension Load Mx = Moment about the X-axis My = Moment about the Y-axis Mz Torsional Moment

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

4. Determine the individual weld stresses (in each principal axis) due to shear, moment and torsion. Weld stress along x-axis due to Px = fx1 = Px / L Weld stress along y-axis due to Py = fy1 = Py / L Weld stress along z-axis due to Pz = fz1 = Pz / L Weld stress along x-axis due to Mz = Weld stress along y-axis due to Mz = Weld stress along z-axis due to Mx = Weld stress along z-axis due to My =
fx 2 = ( Mz Ip ) cy fxy 2 = ( Mz Ip ) cx fz 2 = ( Mx Ix ) cy fz 3 = ( My Iy ) cx

Total weld stress in x-direction: fxtot = fx1 + fx 2 Total weld stress in y-direction: fytot = fy1 + fy 2 Total weld stress in z-direction: fztot = fz1 + fz 2 + fz 3 5. Combine the stresses vectorially. Resultant Weld Stress: fr _ weld =

fxtot

+ fytot

+ fztot

in kips/inch

6. Determine the weld size required for the computed weld stress. Resultant Weld stress shall be less than the weld allowable. Weld Allowable = Effective Throat Thickness x Allowable Weld Stress in kips/inch 7. Check to ensure that the weld size does not exceed the maximum allowed per AISC Manual, Specifications, Section J2. 8. Weld sizes shall also meet the AISC minimum weld size provided in Tables J2.3 and J2.4.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Table 2-2: Properties of Welds Treated as Lines (Courtesy Ref. [4])

CONNECTION DESIGN STANDARD


Connection Types

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Structural steel connections can be classified into the following broad categories. 1. Shear Connections a. Framed Beam Connections (Double-Clip Angle Connections) b. Seated Connections c. End Plate Connection d. Single-Plate Connection 2. Moment Connections a. Directly welded flange type to column flange (flanges are field welded to the column flange and the beam web is field bolted to a shear plate). b. Welded Flange Plate Connection (top flange plate is field welded to the column flange, bottom flange plate is shop welded to the column flange and beam is field welded to the flange plates). c. Shop Welded-Field Bolted Flange Plate Connection (flange plates are shop welded to the column flange and the beam web is field bolted to a shear plate). d. End-Plate Connection (end plate is welded to the beam and field bolted to the column flange). e. Directly welded flange type to column web (flanges are field welded to extension plates welded to the column flange and web and the beam web is field bolted to an extended shear plate). f. Shop Welded-Field Bolted Flange Plate Connection (flange plates are shop welded to the column web and flange flange and the beam web is field bolted to an extended shear plate). g. Moment connections using WT or angles. h. Beam to Beam moment connections (directly welded or using flange plates). i. Other variations of the above listed moment connections 3. Horizontal Bracing Connections 4. Vertical Bracing Connections a. Brace connections at column base b. Chevron Brace connection (Inverted-V brace connection) c. Single and Double brace connections at beam/column intersection d. K-Brace connection e. X-Brace connection 5. HSS Connections a. WF beam to HSS column shear connections b. WF beam to HSS column moment connections c. HSS to HSS shear connections d. HSS to WF beam moment connection 6. Hanger and Post Connections 7. Truss Connections (all bolted, all welded or a combination) a. Angle diagonal and strut to WF chord b. Angle diagonal and strut to WT chord

CONNECTION DESIGN STANDARD


c. WF diagonal and strut to WF chord d. HSS to HSS truss connections (T, K and N type)

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Several variations of the above mentioned connection types are typically encountered in the real world. For example, the framed beam connection for skew beams will have to be designed using bent plates instead of clip angles. Also, parameters such as bolt eccentricity will change depending on the amount of skew and such information shall be considered in the design. Similarly, connections of sloping beams and connections to sloping beams will require additional considerations in design, such as fit up, larger than usual copes, reduced number of bolts, etc. However, these are variations of the basic connection types listed above.

CONNECTION DESIGN STANDARD


Shear Connections

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Framed Beam connections are generally made with a pair of clip angles. Single angle connections can also be used for lightly loaded members and where the beam is not subjected to loads that could cause twisting on it. Single angle connections would require the consideration of eccentricity of the load with respect to the bolt line on the outstanding leg. For evaluation of this eccentricity effect, the procedure given in AISC Manual Part 4, pg. 4-83 is useful. Other framed beam connections involve using bent plates for skew connections, shear plate and extended shear plates. For details of various typical shear connections see Figures 4.1 thru 4.24. 4.1 Double Clip-Angle Connections These are the standard clip angle connections. When supported on column flange, this detail can be used as a Knifed connection (where the beam is lowered into position between the clip angles). For a knifed connection, allowance must be made for erection clearance between the clip angles. This is accommodated by providing slotted holes on the outstanding leg of the clip angles that bolt to the supporting column flange. Four variants using bolts and/or welds can be formulated.

CONNECTION DESIGN STANDARD


4.1.a Shop Bolted / Field Bolted Connection (Detail DCA-BB)

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Formulation for developing load capacity table for Double Bolted Clip Angle Connection using SlipCritical Bolts Step 1: Establish the Design Inputs: Bolt Type, Bolt Diameter (d), Bolt Hole Dia (dh) No. of Bolts (n), Clip-Angle Length (L), Clip-Angle thickness (t), Clip-Angle Yield Strength (Fy_angle) Clip-Angle Tensile Strength (Fu_angle) Beam Yield Strength (Fy), Beam Tensile Strength (Fu), Beam web thickness (tw) Vertical Edge Distance for the top bolt (for coped beams) (lv) Distance from center of bolt hole to beam end (lh) Spacing of bolts (s) Cope depth (dc) Reduced beam depth (ho) Cope length (c) Reduced Section Modulus of the coped beam section (Sn) Supporting member web or flange thickness (t_supt) Step 2: Determine Allowable Bolt Shear in Kips: Use Table II-A, AISC Manual Part 4 (or) Allowable Bolt Shear = n x (double shear capacity of bolt from Table I-D) Step 3: Determine Net Shear on the Angle: Use Table II-C, AISC Manual Part 4 (or) Allowable Net Shear = 2 x [L-n(dh)] x t x 0.3 x Fu_angle Step 4: Determine Beam Web Bearing: Allowable Beam Web bearing load = 1.2 x Fu x d x tw x n Step 5: Determine Beam Block Shear (if beam is coped on top): Determine Coefficients C1 and C2 from Table I-G, AISC Manual Part 4 Block Shear = (C1 + C2) x Fu x tw (or) Block Shear = {(0.3 x lv + 0.5 x lh) + 0.3 [(n-1)(s-dh)-dh/2] dh/4} x Fu x tw Step 6: Check cope based on AISC, Manual of Steel Construction, Vol. II, Appendix B,

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

For checking the beam copes and obtaining the allowable reaction see the procedure outlined in Section 5.3.a.1 and 5.3.a.2. If only a bottom cope is present conservatively assume it as top cope for design. Step 7: Determine Supporting member (web or flange) bearing: For One-Sided Connection: Allowable supporting member (web or flange) bearing load = 1.2 x Fu x d x t_supt x n x 2 For Two-Sided Connection: Conservatively take 50% of the one-sided conn. load Allowable supporting member (web or flange) bearing load = 1.2 x Fu x d x t_supt x n Conclusion: Maximum Allowable Beam End Reaction = Minimum of Loads obtained from Steps 2 through 7. If Actual Reaction exceeds the Allowable, then the following can be done: a. If the governing allowable is due to bolt shear : Either increase number of bolts or increase bolt diameter b. If the governing allowable is due to net shear on the angle, increase angle thickness. c. If the governing allowable is due to beam web bearing : Either increase number of bolts or increase bolt diameter or add web doubler plates d. If the governing allowable is due to block shear : Either increase number of bolts or add web doubler plates e. If the governing allowable is due to beam cope : Reinforce the cope with web doubler plates or horizontal stiffeners f. If the governing allowable is due to supporting member web or flange thickness: Increase the connection depth, or reinforce the support member. Capacity of this connection type for various beam sections is provided in Table CDS 4.1 and Table CDS 4.2 for bearing type and slip-critical type connections. Excel worksheet no. DCA-1 is applicable for evaluating this connection.

The ideal engineer is a composite ... He is not a scientist, he is not a mathematician, he is not a sociologist or a writer; but he may use the knowledge and techniques of any or all of these disciplines in solving engineering problems.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

4.1.b Shop Welded / Field Bolted Connection (Detail DCA-WB) Formulation for developing load capacity table for Double Clip Angle Connection (shop welded to beam web and field bolted to column or beam) using Slip-Critical Bolts Step 1: Establish the Design Inputs: Bolt Type, Bolt Diameter (d), Bolt Hole Dia (dh) No. of Bolts (n), Clip-Angle Length (L), Clip-Angle thickness (t), Clip-Angle In-Standing Leg dimension (ISL) Clip-Angle Yield Strength (Fy_angle) Clip-Angle Tensile Strength (Fu_angle) Beam Yield Strength (Fy), Beam Tensile Strength (Fu), Beam web thickness (tw) Cope depth (dc) Reduced beam depth (ho) Cope length (c) Reduced Section Modulus of the coped beam section (Sn) Weld Electrode E70XX, Fu = 70 ksi Distance from top of clip angle to edge of beam cope (a) Supporting member web or flange thickness (t_supt) Step 2: Determine Allowable Bolt Shear in Kips: Use Table II-A, AISC Manual Part 4 (or) Allowable Bolt Shear = 2 x n x (single shear capacity of bolt from Table I-D) Step 3: Determine Net Shear on the Angle: Use Table II-C, AISC Manual Part 4 (or) Allowable Net Shear = 2 x [L-n(dh)] x t x 0.3 x Fu_angle Step 4: Determine Weld Capacity: Use Table III, AISC Manual Part 4, Weld A Capacity Based on angle length and weld size (limited by the beam web size) obtain Weld Capacity. If the actual web thickness is less than the minimum required web thickness provided in the Table, then Revised Allowable = tw x Weld Allowable per Table / Min. web thickness per Table Step 5: Determine Beam Block Shear (if beam is coped on top): Block Shear = 0.4 x Fy x (L + a) x tw + 0.5 x Fu x (ISL setback) x tw Step 6: Check cope based on AISC, Manual of Steel Construction, Vol. II, Appendix B,

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

For checking the beam copes and obtaining the allowable reaction see the procedure outlined in Section 5.3.a.1 and 5.3.a.2. If only a bottom cope is present conservatively assume it as top cope for design. Step 7: Determine Supporting member (web or flange) bearing: For One-Sided Connection: Allowable supporting member (web or flange) bearing load = 1.2 x Fu x d x t_supt x n x 2 For Two-Sided Connection: Conservatively take 50% of the one-sided conn. load Allowable supporting member (web or flange) bearing load = 1.2 x Fu x d x t_supt x n Conclusion: Maximum Allowable Beam End Reaction = Minimum of Loads obtained from Steps 2 through 7. If Actual Reaction exceeds the Allowable, then the following can be done: a. If the governing allowable is due to bolt shear : Either increase number of bolts or increase bolt diameter b. If the governing allowable is due to net shear on the angle, increase angle thickness. c. If the governing allowable is due to Weld capacity : Either increase weld size or increase weld length by increasing clip angle length, if possible. d. If the governing allowable is due to block shear : Add web doubler plates e. If the governing allowable is due to beam cope : Reinforce the cope with web doubler plates or horizontal stiffeners. f. If the governing allowable is due to supporting member web or flange thickness: Increase the connection depth, or reinforce the support member. Capacity of this connection type for various beam sections is provided in Table CDS 4.3 through Table CDS 4.6 for bearing type and slip-critical type connections. Excel worksheet no. DCA-2 is applicable for evaluating this connection.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

4.1.c Shop Bolted / Field Welded Connection (Detail DCA-BW) Formulation for developing load capacity table for Double Clip Angle Connection (Shop Bolted / Field Welded Connection) using Slip-Critical Bolts Step 1: Establish the Design Inputs: Bolt Type, Bolt Diameter (d), Bolt Hole Dia (dh) No. of Bolts (n), Clip-Angle Length (L), Clip-Angle thickness (t), Clip-Angle Yield Strength (Fy_angle) Clip-Angle Tensile Strength (Fu_angle) Beam Yield Strength (Fy), Beam Tensile Strength (Fu), Beam web thickness (tw) Vertical Edge Distance for the top bolt (for coped beams) (lv) Distance from center of bolt hole to beam end (lh) Spacing of bolts (s) Cope depth (dc) Reduced beam depth (ho) Cope length (c) Reduced Section Modulus of the coped beam section (Sn) Weld Electrode E70XX, Fu = 70 ksi Supporting member web or flange thickness (t_supt) Supporting Member Yield Strength (Fy_Supt), Step 2: Determine Allowable Bolt Shear in Kips: Use Table II-A, AISC Manual Part 4 (or) Allowable Bolt Shear = n x (double shear capacity of bolt from Table I-D) Step 3: Determine Net Shear on the Angle: Use Table II-C, AISC Manual Part 4 (or) Allowable Net Shear = 2 x [L-n(dh)] x t x 0.3 x Fu_angle Step 4: Determine Beam Web Bearing: Allowable Beam Web bearing load = 1.2 x Fu x d x tw x n Step 5: Determine Beam Block Shear (if beam is coped on top): Determine Coefficients C1 and C2 from Table I-G, AISC Manual Part 4 Block Shear = (C1 + C2) x Fu x tw (or) Block Shear = {(0.3 x lv + 0.5 x lh) + 0.3 [(n-1)(s-dh)-dh/2] dh/4} x Fu x tw

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Step 6: Check cope based on AISC, Manual of Steel Construction, Vol. II, Appendix B, For checking the beam copes and obtaining the allowable reaction see the procedure outlined in Section 5.3.a.1 and 5.3.a.2. If only a bottom cope is present conservatively assume it as top cope for design. Step 7: Check Weld on the Outstanding leg of the clip angle: Use Table III, AISC Manual Part 4, Weld B Capacity Based on angle length and Required weld capacity obtain the weld size. Note: Connection capacity may be limited by the shear capacity of the supporting member. Hence check the following: For One-Sided Connection: For Fy_Supt = 36 ksi, weld size shall be <= support member web or flange thickness For Fy_Supt = 50 ksi, weld size shall be <= (support member web or flange thickness) x 1.35 For Two-Sided Connection: (see note) For Fy_Supt = 36 ksi, weld size shall be <= support member web x 0.5 For Fy_Supt = 50 ksi, weld size shall be <= support member web x 0.67 Note: This approach may or may not be conservative depending on the weld size of the opposing connection. This assumes that the weld size of the connections on either side of the web is the same. Conclusion: Maximum Allowable Beam End Reaction = Minimum of Loads obtained from Steps 2 through 7. If Actual Reaction exceeds the Allowable, then the following can be done: a. If the governing allowable is due to bolt shear : Either increase number of bolts or increase bolt diameter b. If the governing allowable is due to net shear on the angle, increase angle thickness. c. If the governing allowable is due to beam web bearing : Either increase number of bolts or increase bolt diameter or add web doubler plates d. If the governing allowable is due to block shear : Either increase number of bolts or add web doubler plates e. If the governing allowable is due to beam cope : Reinforce the cope with web doubler plates or horizontal stiffeners f. If the governing allowable is due to weld on the outstanding leg: Increase the weld size (if possible), or increase weld length by increasing the length of the clip angle (if possible) or reinforce the supporting member web or flange to allow a bigger weld. Excel worksheet no. DCA-3 is applicable for evaluating this connection.

CONNECTION DESIGN STANDARD


4.1.d Shop Welded / Field Welded Connection (Detail DCA-WW)

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Formulation for developing load capacity table for Double Clip Angle Connection (shop welded to beam web and field welded to column or beam) Step 1: Establish the Design Inputs: Clip-Angle Length (L), Clip-Angle thickness (t), Clip-Angle In-Standing Leg dimension (ISL) Clip-Angle Yield Strength (Fy_angle) Clip-Angle Tensile Strength (Fu_angle) Beam Yield Strength (Fy), Beam Tensile Strength (Fu), Beam web thickness (tw) Cope depth (dc) Reduced beam depth (ho) Cope length (c) Reduced Section Modulus of the coped beam section (Sn) Weld Electrode E70XX, Fu = 70 ksi Distance from top of clip angle to edge of beam cope (a) Supporting member web or flange thickness (t_supt) Supporting Member Yield Strength (Fy_Supt), Step 2: Check Weld on the Outstanding leg of the clip angle: Use Table III, AISC Manual Part 4, Weld B Capacity Based on angle length and Required weld capacity obtain the weld size. Note: Connection capacity may be limited by the shear capacity of the supporting member. Hence check the following: For One-Sided Connection: For Fy_Supt = 36 ksi, weld size shall be <= support member web or flange thickness For Fy_Supt = 50 ksi, weld size shall be <= (support member web or flange thickness) x 1.35 For Two-Sided Connection: (see note) For Fy_Supt = 36 ksi, weld size shall be <= support member web x 0.5 For Fy_Supt = 50 ksi, weld size shall be <= support member web x 0.67 Note: This approach may or may not be conservative depending on the weld size of the opposing connection. This assumes that the weld size of the connections on either side of the web is the same. Step 3: Determine Shear on the Angle: Allowable Net Shear = 2 x L x t x 0.4 x Fy_angle Step 4: Determine Weld Capacity on the beam web: Use Table III, AISC Manual Part 4,

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Weld A Capacity Based on angle length and weld size (limited by the beam web size) obtain Weld Capacity If the actual web thickness is less than the minimum required web thickness provided in the Table, then Revised Allowable = tw x Weld Allowable per Table / Min. web thickness per Table Step 5: Determine Beam Block Shear (if beam is coped on top): Block Shear = 0.4 x Fy x (L + a) x tw + 0.5 x Fu x (ISL setback) x tw Step 6: Check cope based on AISC, Manual of Steel Construction, Vol. II, Appendix B, For checking the beam copes and obtaining the allowable reaction see the procedure outlined in Section 5.3.a.1 and 5.3.a.2. If only a bottom cope is present conservatively assume it as top cope for design. Conclusion: Maximum Allowable Beam End Reaction = Minimum of Loads obtained from Steps 2 through 6. If Actual Reaction exceeds the Allowable, then the following can be done: a. If the governing allowable is due to weld on the outstanding leg : Increase the weld size (if possible), or increase weld length by increasing the length of the clip angle (if possible), or reinforce the supporting member web or flange to allow a bigger weld. b. If the governing allowable is due to shear on the angle, increase angle thickness. c. If the governing allowable is due to Weld capacity on the beam web : Either increase weld size or increase weld length by increasing clip angle length, if possible. d. If the governing allowable is due to block shear : Add web doubler plates e. If the governing allowable is due to beam cope : Reinforce the cope with web doubler plates or horizontal stiffeners Excel worksheet no. DCA-4 is applicable for evaluating this connection.

CONNECTION DESIGN STANDARD


4.2 Single Plate Connections

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Two types of single plate connections are possible. One is the normal single-plate shear connection and the other is the extended shear plate connection. References to Technical Papers: 1. Behavior and Design of Single Plate Shear Connections, by Abolhassan Astaneh 2. Designing with Single Plate Connections, by M. Thomas Ferrell 3. Design Procedures for Extended Shear Tabs, by Al Ghorbanpoor and Donald R. Sherman Formulation for design of single plate connection Step 1: Establish the Design Inputs: Bolt Type, Bolt Diameter (d), Bolt Hole Dia (dh) No. of Bolts (n), Plate Length (L), Plate thickness (tp), Plate Yield Strength (Fy_plate) Plate Tensile Strength (Fu_plate) Beam Yield Strength (Fy), Beam Tensile Strength (Fu), Beam web thickness (tw) Cope depth (dc) Reduced beam depth (ho) Cope length (c) Reduced Section Modulus of the coped beam section (Sn) Weld Electrode E70XX, Fu = 70 ksi Vertical Edge Distance for the top bolt (for coped beams) (lv) Distance from center of bolt hole to beam end (lh) Vertical Edge Distance for the top bolt from plate edge (lvp) Distance from center of bolt hole to plate end (lhp) Distance of bolt line from the weld (a) Supporting member web or flange thickness (t_supt) Supporting Member Yield Strength (Fy_Supt), The single plate is welded to the support member and bolted to the beam. The bolts have to be designed for the shear and moment due to the eccentricity. The eccentricity depends on the support type and the type of holes used in the plate. For flexible support (i.e. when a beam frames into another beam from one side only or when a heavy girder frames into a light column) with standard holes, eccentricity shall be taken as

CONNECTION DESIGN STANDARD


eb = |(n-1)| -a| >= a

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

For flexible support (i.e. when a beam frames into another beam from one side only or when a heavy girder frames into a light column) with slotted holes, eccentricity shall be taken as eb = |2n/3-a| >= a For rigid support (i.e. when a beam frames into a heavy column flange) with standard holes, eccentricity shall be taken as eb = |(n-1)| -a| For rigid support (i.e. when a beam frames into a heavy column flange) with slotted holes, eccentricity shall be taken as eb = |2n/3-a| When two beams frame on either side of a beam/girder: Use eb = a Step 2: Design parameters shall be based on the following rules: a. Ideally the support is somewhere between flexible and rigid. Hence, the larger value of eb shall be taken. b. For any combination of support condition and hole type, the E70 electrode maximum weld size need not exceed of the plate thickness for A36 plate material. c. Distance of bolt line from the weld (a) shall be preferably 2 and a maximum of 3. For use of Tables in AISC manual this shall not exceed 3. d. Minimum plate length shall be one-half of the T-dimension of beam to be supported. e. The minimum plate thickness should be such that tpmin >= L/64 >= f. The maximum plate thickness should be d/2 + 1/16 in > = tpmin g. Weld to be designed for maximum of Actual Reaction or 0.4 x Fy_plate x L x tp Step 3 Determine Bolt Group Capacity: Using Table XI or XII, l = eb and knowing n, determine Coefficient C Bolt Group Capacity = Rb = C x rv Where rv = Single shear bolt capacity from Table I-D Step 4: Determine Plate bearing Capacity: Allowable Plate bearing load = 1.2 x Fu_plate x tp x d x n

CONNECTION DESIGN STANDARD


Step 5: Check Shear Yielding Capacity of Plate: 0.4 x Fy_plate x L x tp Step 6: Check Shear rupture of plate: 0.3 x Fu_plate x [ L n(dh)] x tp

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Step 7: Check Plate Block Shear: Determine Coefficients C1 and C2 from Table I-G, AISC Manual Part 4 Block Shear_plate = (C1 + C2) x Fu_plate x tp (or) Block Shear_plate ={(0.3 x lvp + 0.5 x lhp) +0.3 [(n-1)(s-dh)-dh/2] dh/4}x Fu_plate x tp Step 8: Determine Beam Web Bearing: Allowable Beam Web bearing load = 1.2 x Fu x d x tw x n Step 9: Determine Beam Block Shear (if beam is coped on top): Determine Coefficients C1 and C2 from Table I-G, AISC Manual Part 4 Block Shear = (C1 + C2) x Fu x tw (or) Block Shear = {(0.3 x lv + 0.5 x lh) + 0.3 [(n-1)(s-dh)-dh/2] dh/4} x Fu x tw Step 10: Check cope based on AISC, Manual of Steel Construction, Vol. II, Appendix B, For checking the beam copes and obtaining the allowable reaction see the procedure outlined in Section 5.3.a.1 and 5.3.a.2. If only a bottom cope is present conservatively assume it as top cope for design. Step 11: Determine Weld Capacity: For Rigid Connection and when beams frame on two sides of a girder: Eccentricity to be used for design of weld = ew = a + eb For Flexible Connection : Eccentricity to be used for design of weld = 0 Using Table XIX, AISC Manual Allowable weld capacity Pw = C x C1 x D x L Where D = Number of sixteenth of an inch in fillet weld size C1 = 1.0 for E70 Electrode And 0.857 for E60 Electrode C is obtained from the Table XIX for a = ew/L Note: Connection capacity may be limited by the shear capacity of the supporting member. Hence check the following: For One-Sided Connection: For Fy_Supt = 36 ksi, weld size shall be <= support member web or flange thickness For Fy_Supt = 50 ksi, weld size shall be <= (support member web or flange thickness) x 1.35

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

For Two-Sided Connection: (see note) For Fy_Supt = 36 ksi, weld size shall be <= support member web x 0.5 For Fy_Supt = 50 ksi, weld size shall be <= support member web x 0.67 Note: This approach may or may not be conservative depending on the weld size of the opposing connection. This assumes that the weld size of the connections on either side of the web is the same. Conclusion: Maximum Allowable Beam End Reaction = Minimum of Loads obtained from Steps 3 through 11. If Actual Reaction exceeds the Allowable, then the following can be done: a. If the governing allowable is due to bolt shear : Either increase number of bolts or increase bolt diameter. b. If the governing allowable is due to plate bearing : Either increase number of bolts or plate thickness or bolt diameter c. If the governing allowable is due to plate shear yielding : Either increase plate length or plate thickness. d. If the governing allowable is due to plate shear rupture : Either increase plate length or plate thickness. e. If the governing allowable is due to plate block shear : Either increase number of bolts or increase plate thickness f. If the governing allowable is due to beam web bearing : Either increase number of bolts or increase bolt diameter or add web doubler plates g. If the governing allowable is due to beam web block shear : Either increase number of bolts or add web doubler plates h. If the governing allowable is due to beam cope : Reinforce the cope with web doubler plates or horizontal stiffeners i. If the governing allowable is due to weld: Increase the weld size, or increase weld length by increasing the length of the plate, if possible. Excel worksheet no. SSPC-1 is applicable for evaluating this connection.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

4.2.a Additional considerations for Extended Shear Plate Connection Unstiffened extended shear plate connections should be avoided as much as possible. When a beam framing into the column web has to stop short of the column flange or when a beam framing into the web of a girder has to stop short of the flange of the supporting girder, the following shall be done to avoid the situation of an unstiffened extended shear tab. 1. If the beam is framing into another beam, the shear plate shall be welded to the top and bottom flange and the distance of the bolt line from the edge of the flange shall not exceed 3. 2. If the beam is framing into the column web, a pair of horizontal stiffeners shall be provided and welded to the column flange and webs. The shear plate shall be welded to the top and bottom horizontal stiffeners. The distance of the bolt line from the end of the horizontal column web stiffener shall not exceed 3. The point at weld is considered to be a pin-support subjected to shear only. The bolts and the plate shall be checked for the moment equal to the reaction times the eccentricity of the bolt line from the weld line. Additional checks required when extended shear tab cannot be stiffened (this situation shall be avoided) If the distance a exceeds 3 due to fit-up and constructability constraints, additional check for plate thickness has to be done to check for stability. Also, if the horizontal web stiffener cannot be provided in the column web, the column web has to be checked for yielding. The eccentricity of the reaction force with respect to bolt line shall also be recalculated. For these additional checks and eccentricity calculation refer to the Design Procedures for Extended Shear Tabs by Al Ghorbanpoor and Donald R. Sherman.

CONNECTION DESIGN STANDARD


4.3 Seated Beam Connections 4.3.a Unstiffened Seated Beam Connections

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

The beam is supported on a seat that is not stiffened. The unstiffened seat is designed to carry the entire reaction. Note: Always provide a top angle, which provides lateral support to the compression flange. As an alternate, the top angle could also be placed on one side of the beam web at the top. The design of unstiffened seat (bolted or welded) requires the following steps. Step 1: Establish the Design Inputs: Bolt Type, Bolt Diameter (d), No. of Bolts (n), Outstanding Leg (OSL) of seat angle = 4 Length of Seat Angle Seat Angle Yield Strength (Fy_angle) Beam Yield Strength (Fy), Beam web thickness (tw) Weld Electrode E70XX, Fu = 70 ksi Beam End Reaction: R Step 2: Using Table V-A (for Fy = 36 ksi) or Table V-B (Fy = 50 ksi) and for the given beam web thickness (tw) and reaction R, determine the seat angle thickness required. Note that for welded seated angle, use Tables VI-A and VI-B in lieu of Tables V-A and V-B. Step 3: For Bolted Connection: Using Table V-C and knowing the bolt type, pick the connection type and bolt diameter that satisfies the required beam end reaction. Note that Connection Types A, B and C are good for Column Flanges only, while Connection Types A thru F can be used on column or beam webs. For Welded Connection: Using Table VI-C, pick the seat angle size, thickness and weld size that satisfies the required beam end reaction. Step 4: Check for Beam Web Crippling: Determine values R3 and R4 from the Allowable Uniform Load Tables. Allowable Load due to Beam Web crippling is (R3 + NxR4), where N is the bearing length on the OSL (taken as length of OSL). Conclusion: If the Beam Web Crippling limits the allowable reaction, beam web stiffeners shall be provided as specified in AISC Manual, Chapter K, Section K1.4. If the Actual Reaction exceeds the Allowable as obtained from the Tables, provide a stiffened seated connection.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

4.3.b Stiffened Seated Beam Connections 4.3.b.1 Bolted Stiffened Seated Beam Connections The beam is supported on a seat that is stiffened by a pair of angles. Note: Always provide a top angle, which provides lateral support to the compression flange. As an alternate, the top angle could also be placed on one side of the beam web at the top. The design of bolted stiffened seat requires the following steps. Step 1: Establish the Design Inputs: Bolt Type, Bolt Diameter (d), No. of Bolts (n), Outstanding Leg (OSL) of stiffener angle ( Stiffener Angle Yield Strength (Fy_angle) Beam Yield Strength (Fy), Beam web thickness (tw) Beam End Reaction: R Step 2: Using the Allowable Uniform Load Table, determine values for R1, R2, R3 and R4. Based on these values, determine the required bearing length N to prevent beam web yielding or crippling. This will determine the Outstanding Leg length required for the stiffener angle. The seat plate shall be 3/8 thick and shall extend past the stiffener angle. Step 3: Using Table VII-A (for Fy_angle = 36 ksi or 50 ksi) and for the assumed outstanding leg as determined in Step 2, determine the stiffener angle thickness required that satisfies the reaction R. Step 4: Using Table VII-B and knowing the bolt type, pick the bolt diameter and the fasteners required per row that satisfies the required beam end reaction. Step 5: Check for Supporting Column flange/web or beam web bearing: Determine the load per bolt and compare to allowable bearing values given in Table I-E. Actual load shall be less than the allowable bearing load. Conclusion: If the Beam Web Crippling limits the allowable reaction, beam web stiffeners shall be provided as specified in AISC Manual, Chapter K, Section K1.4. If the Actual Reaction exceeds the Allowable as obtained from the Tables, try with larger bolt size or larger number of bolts or thicker stiffener angle size, etc. and repeat steps 2 thru 5.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

4.3.b.2 Welded Stiffened Seated Beam Connections For the design of welded stiffened seated beam connection, use the procedure in AISC Manual of Steel Construction, Vol I, Table VIII. The following shall be checked as part of the design. a. Beams have to be connected to seat by high-strength A325 or A490 erection bolts or the bottom flange welded to the seat for a length of 2 on each side of the flange. If the bottom flange is bolted, the location of the centerline of the bolts (B) shall be the greater of 0.50W or 2 5/8, where W is the Seat width measured along the beam. b. Where seated connection width, W is 7, 8 or 9, limit B to 3 , except for W14x43 column where B shall be limited to 3. c. Top angle of minimum thickness shall be welded or bolted in place. d. For beams supported off the column web, the seat plate shall not be welded to column flanges. e. Maximum weld size is column web thickness for one sided connection. For two sided connection maximum weld size is 0.5 x web thickness for A36 steel and 0.67 x web thickness for 50 ksi steel. f. Thickness of the seat plate or the flange of a WT shall be minimum 3/8. The design of stiffened seat (welded) requires the following steps. Step 1: Establish the Design Inputs: Beam Yield Strength (Fy), Beam web thickness (tw) Weld Electrode E70XX, Fu = 70 ksi Seat Plate Material Stiffener Plate Material Beam End Reaction: R Step 2: Using the Allowable Uniform Load Table, determine values for R1, R2, R3 and R4. Based on these values, determine the required bearing length N. This will determine the value of W to be used in Table VIII. Step 3: Seat Plate Width measured along the flange (B) = Flange width + 4 x weld thickness Step 3: Using Table VIII and seat width W as determined in Step 2, and for a given beam end reaction and weld size, the length of the stiffener L can be obtained. The length of the stiffener shall be such that (B-stiffener thickness) >= 0.4 x L.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Also, the minimum weld between the seat and the stiffener is 0.4L, i.e. 0.2L on either side of the stiffener. Step 3: Check that the stiffener plate thickness is equal to 2 x weld thickness when material is A36 or at least 1.5 x weld thickness when the material is 50 ksi. Conclusion: 1. If connection capacity as given by AISC Table does not meet the actual reaction, reinforcing of the column web to be able to provide a thicker weld can be looked at. 2. Alternately, a double clip angle connection can be proposed.

CONNECTION DESIGN STANDARD


4.4 Special Considerations for Framed Beam Connections 4.4.a Coped Beams Copes can affect the beam in two ways:

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

1. Reduction in out-of-plane rotational restraint which reduces the resistance to lateral torsional buckling - Needs to be considered at the time of beam design and hence is not in the scope of connection design. 2. May result in local buckling failure of the web. This would require reinforcement of the web. Hence this check is needed as part of the connection design. As a design guideline, the following shall set the limit of the copes for which a check of the cope is not warranted. Beam cope check shall be done if the cope exceeds the copes given in Table CDS 4.7 and Table CDS 4.8. These copes are based on using a 5/16 thick clip angle with diameter A325SC bolts.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

4.4.a.1 Case 1 - Check of beams coped at top flange only Check cope based on AISC, Manual of Steel Construction, Vol. II, Appendix B, Critical buckling stress of the compression portion shall be checked using Eqn. B-1. For ASD design the allowable buckling stress is based on a factor of safety of 1.67. The allowable bucking stress Fbc is computed using Eqn. B-2. Variables: ho = Reduced beam depth tw = Beam web thickness c = Cope length dc = Cope depth d = Depth of the beam Sn = Reduced Section Modulus of the coped beam section (Obtained from AISC Manual, Vol II, Table B-1 or calculated if not available in the Table) e = cope length ( c ) + beam setback Fy = Yield-strength of the beam Step 1: Check if c <= 2d and dc <= d/2 Step 2: Compute c/ho and determine k using Eqn. B-3 Step 3: Compute c/d and determine f using Eqn. B-4 Step 4: Compute Allowable buckling stress, Fbc using Eqn. B-2. Step 5: Compute Allowable Shear based on cope bending, Rall = (Fbc x Sn)/e Step 6: Compute Allowable Web Shear on the reduced section as Vall = 0.4 x Fy x tw x ho Step 7: Maximum Allowable Reaction, Rmax, all = Maximum (Rall, Vall) Step 8: Is Rmax,all > Actual Reaction If Yes, no web reinforcement is required. End of beam cope check. If No, Web Reinforcement is required. Excel Worksheet COPE-1 is available for checking beams with top cope.

CONNECTION DESIGN STANDARD


4.4.a.2 Case 2 - Check of beams coped at top and bottom flanges Check cope based on AISC, Manual of Steel Construction, Vol. II, Appendix B,

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Critical buckling stress of the compression portion shall be checked using Eqn. B-5. For ASD design the allowable buckling stress is based on a factor of safety of 1.67. The allowable bucking stress Fbc is computed using Eqn. B-6. Variables: ho = Reduced beam depth tw = Beam web thickness c = Cope length dc = Cope depth d = Depth of the beam Sn = Reduced Section Modulus of the coped beam section (Obtained from AISC Manual, Vol II, Table B-1 or calculated if not available in the Table) e = cope length ( c ) + beam setback Fy = Yield-strength of the beam Step 1: Check if c <= 2d and dc <= 0.2d Step 2: Compute fd = 3.5 7.5(dc / d) Step 3: Compute Allowable buckling stress, Fbc using Eqn. B-6. Allowable buckling stress cannot exceed 0.6Fy. Step 4: Compute Allowable Shear based on cope bending, Rall = (Fbc x Sn)/e Step 6: Compute Allowable Web Shear on the reduced section as Vall = 0.4 x Fy x tw x ho Step 7: Maximum Allowable Reaction, Rmax, all = Maximum (Rall, Vall) Step 8: Is Rmax,all > Actual Reaction If Yes, no web reinforcement is required. End of beam cope check. If No, Web Reinforcement is required. Excel Worksheet COPE-1 is available for checking beams with top and bottom copes.

CONNECTION DESIGN STANDARD


4.5 Design of Web Reinforcement

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Webs can be either reinforced with web doubler plates or web stiffener plates. The design of these elements will be discussed here. Note that the welded web doubler plates and the welded horizontal stiffener plates will be discussed here since these are the most common applications. For the design of bolted web doubler plate, see AISC, Manual of Steel Construction, Vol II, Connections, Appendix B. Other option such as Welded Tee Section is also possible but is not the preferred with many fabricators. Hence it will not be discussed here. 4.5.a Design of Welded Web Doubler Plates Step 1: Design force for the design of web doubler plate = Rwdp = Actual Reaction Rmax,all Step 2: Design Moment for doubler plate design = Mwdp = Rwdp x (c + setback) Step 3: Determine Doubler Plate thickness: twdp twdp = [(Mwdp x 6)/(dwdp2 x 0.6*Fywdp) ] x 0.5 (assumed two plates provided) Where dwdp = depth of web doubler plate Fywdp = yield strength of the web doubler plate Step 4: Check shear capacity of the web doubler plate: Vwdp = twdp x dwdp x 0.4 x Fywdp Vwdp shall be greater than Rwdp Step 4: Design the weld between the web doubler plates and the beam web. Check Weld for shear forces and the moment due to eccentricity. Step 5: Extend the doubler plate at least a distance dc beyond the cope to prevent web crippling.

CONNECTION DESIGN STANDARD


4.5.b Design of Horizontal Stiffener Plates Step 1: Select a plate size to start with, e.g. tpl x wpl Where tpl = plate thickness wpl = plate width Step 2: Calculate the reinforced section properties I and S Step 3: Determine Allowable Shear/Reaction as Rmax_all_revised = (0.6 x Fy_beam)x S / e

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Step 4: Is Rmax_all_revised > Actual Reaction If Yes, selected plate size is adequate or could be optimized if design margin is high If No, increase plate size (thickness or width and repeat Steps 1 thru 4)

CONNECTION DESIGN STANDARD


5.0 Moment Connections

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

These are rigid frame connections classified as AISC Type 1 connections. The design of these connections is concerned with developing the full-plastic moment capacity at the joint. There are several varieties of beam to column flange moment connections such as a. Directly welded flange (field welded) b. Top and bottom flange plate (welded and bolted variety) c. End Plate d. Split Tee on top and bottom flanges e. Top and bottom angles (rarely used) Other moment connections are also possible. Beam to column web moment connections can be made using connection types a or b by introducing an extension plate in the column web. Beam to beam moment connections can be made by directly welding the flange of the beam to the supporting girder flange or web. Flange plates can be used as well. For design of Directly welded flange connection see AISC Manual, pg 4-106 through 4-108. For design of moment connections with flange plates see AISC Manual, pgs 4-100 through 4-105 and 4109 thru 4-115. For design of moment connections with end plate see AISC Manual, pg. 4-116 through 4-125. Excel worksheet no. MC-TBFP-1 and MC-TBFP-2 are applicable for evaluating the moment connection using top and bottom flange plates. For details of various typical moment connections see Figures 5.1 thru 5.6

CONNECTION DESIGN STANDARD


6.0 Truss and Vertical Bracing Connections

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Trusses are used when the span gets large and it becomes uneconomical or unfeasible to use rolled shapes or plate girders. The loads in a truss travel as axial loads through the truss members. Typically members that carry gravity loads are called trusses. The connections associated with the diagonal members of the truss with the chord members or at the supports at a column and/or beam are called Truss Connections. The same truss when laid on its side can be used as horizontal trusses in a floor to carry the lateral loads, say from a rotating equipment or crane runway, etc. The connections of the bracing members that form the horizontal truss are called Horizontal Bracing Connections. Another use of trusses is to provide stability to a structure against lateral sway and to resist wind and seismic forces. These trusses resist the lateral forces of wind and seismic of the structure and transmit these forces ultimately to the foundation. Such trusses form the lateral force resisting system for a building, also called as the vertical bracing system for the structure. The connections for these vertical bracing systems can get very complex based on the magnitude of loading. The design methodology for a truss connection or vertical bracing connection is similar. All truss connections and vertical bracing connections shall be designed using DESCON. DESCON uses the Uniform Force Method concept for designing the connections at the supports. For design of truss connections and vertical bracing connections, refer to AISC Manual, Vol II, Connections, Chapter 7. For details of various typical truss and vertical bracing connections see Figures 6.1 thru 6.26.

CONNECTION DESIGN STANDARD


7.0 Horizontal Bracing Connections

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Horizontal trusses can be used in a floor to carry the lateral loads, say from a rotating equipment or crane runway, etc to the supporting girder that eventually transmits it to a lateral load resisting system. The connections of the bracing members that form the horizontal truss are called Horizontal Bracing Connections. These are typically encountered in industrial structures where grating floors are supported on steel frames and concrete flors are not present to transmit the lateral loads through diaphragm action. In such instances, horizontal bracing system is employed to carry the lateral loads from the floor to the supports. For design of horizontal bracing support, the brace load is broken down into its components along the beams longitudinal axis and perpendicular to it. Usually the load component perpendicular to the beam is negligible unless there is a transfer force at that panel point. Hence typical connection is a shear connection oriented horizontally. The brace is welded or bolted to the gusset and the gusset is in turn connected to the supporting beam in the following manner. a. Directly bolted to the bottom flange of the beam b. Connected to the beam web using a shear tab c. Connected to the beam web using a single clip angle d. Connected to the beam web using double clip angle if load is high For details of various typical horizontal bracing connections see Figures 7.1 thru 7.6

CONNECTION DESIGN STANDARD


8.0 Splices

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Splices are specified for beams, columns and plate girders for various reasons. Splices are required when the rolled section are not be available in the lengths required, or the fabricator chooses to specify a splice for ease of shipping and erection or when the designer chooses to vary the crosssection of the member. Splices can be either simple shear splice or those that provide continuity to a member in which case it shall be designed for both shear and moment. Splices can be all welded or all bolted or a combination of welded and bolted connection. For details of various typical splices see Figures 8.1 thru 8.4.

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

APPENDIX A
CONNECTION CAPACITY TABLES

CONNECTION DESIGN STANDARD

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

APPENDIX B
CONNECTION SUMMARY TABLE TEMPLATES

CONNECTION DESIGN STANDARD


APPENDIX C Design Software and Worksheets

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

Design of Standard AISC connections using the AISC prescribed methodology can be done using the software DESCON. There are four modules in DESCON. They are a. Descon Win-ASD, Version 4.1 b. Descon Brace-ASD, Version 4.1 c. Descon Win-LRFD, Version 5.0 d. Descon Brace-LRFD, Version 4.1 Modules a and c are helpful for designing shear, moment and splice connections. Module c can design FEMA-350 connections as well. Modules b and d are used for designing lateral bracing connections in ASD or LRFD respectively. In addition, several worksheets are available for designing various types of connections. The list of worksheet is as follows: Connection Type Shear Connection Shear Connection Shear Connection Shear Connection Shear Connection Shear Connection Shear Connection Shear Connection Shear Connection Shear Connection Worksheet No. DCA-1 DCA-2 DCA-3 DCA-4 COPE-1 SSPC-1 SBC-1 SBC-2 SBC-3 SBPC-1 Description Double Clip Angle Connection Bolted/Bolted Double Clip Angle Connection Welded/Bolted Double Clip Angle Connection Bolted/Welded Double Clip Angle Connection Welded/Welded Beam to Beam Cope check only Single Shear Plate Connection Seated Beam Connection Unstiffened (Bolted / Bolted and Bolted / Welded) Seated Beam Connection Stiffened (Bolted ) Seated Beam Connection Stiffened (Welded ) Single Bent Plate Connection (Double bolted)

CONNECTION DESIGN STANDARD


Shear Connection Moment Connection Moment Connection Moment Connection Moment Connection Moment Connection Bearing Connection Bracing Connection Splicing Connection Splicing Connection Splicing Connection SBPC-2 MC-FW-B-C-1 MC-SW/FB-1 MC-HSS-HSS-1 MC-HSS-WCW-1 MC-WF-HSS-TPL-1 BEARING PLATE-1 BSC-GPL-CB-1 BEAM-SPLICE-CA/FP-1 SPLICE-BEAM-1 SPLICE-COLUMN-1 Single Bent Plate Connection Welded/Bolted Field Welded Moment Connection between Beam and Column Shop Welded Field Bolted Moment Connection between Beam and Column HSS beam to HSS column Moment Connection HSS beam to Wide flange Column Web Moment Connection Wide flange beam to HSS Column Moment Connection w/ Through Plate Bearing Plate design Checks for Bolt Shear Capacity and Gusset Plate of Cross Bracing Beam Splice using Clip Angle for Web splice and Flange Plate for flange splice Beam to Beam splice Connection Column Splice connection

DOC NO: CDS-1 Prep by: JVJ Chkd by: MNG

You might also like