GAS SENSOR & APPLICATIONS
CEO Message
Though our country, Korea has an excellent competitiveness based on the technology even in the global endless competition days, the dependence on the advanced countries is a as high as what it could be said to be technically governed in the gas sensor and gas safety equipment industry. The gas sensor technology which could create the high additional value grafting with another industries, is one of the prospective technology which are growing very fast, as the environment and safety are being highly concerned. Senko Co., Ltd had developed sensors of the carbon monoxide, hydrogen sulfide by our own technology, starting the oxygen sensor, We had also developed to produce the gas safety equipment and its system such as the portable gas detector in the industrial field. We have been doing our best to localize the Korean domestic market which dominated by foreign countries products as well as to develop the oversea market. We will do our every possible efforts to be together wherever with our customer and surely stand based on the venture enterprise spirit in the industrial safety gas equipment area which the domestic enterprise never concerned, We are trying to develop the more efficient, convenient products for the customers, using the new technology as well as the conventional gas safety equipment. We will establish the strategic partnership with the excellent institute/enterprise who have the technical competitiveness in another industries We will be born again to focus to develop the new product of the high additional value technically fused through the co-research based on this partnership. Being one family based on the mutual trust to become the world wide company, we will found the business culture which all staffs could do our best. We promise to show our customers our efforts to do our best for the customer satisfaction. Please watch us with the friendly warm view. Thanks.
s
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 23
Portable Single Gas Detector Portable Multi Gas Detector Sampling Pump/ Charger Portable LPG/LNG Detector Portable Gas Leak Detector Wireless Gas Detector Controller For Fixed Gas Detector Wireless Gas/ Fire Monitoring System Wireless Odor Gas Monitoring System Controller For Wireless Gas Detector Wireless Gas Detector/ Wireless fire detector Combustible Gas Leak Detector Gas Detector & Shut-Off Valve For Home Safety Breath CO Monitor Gas Sensor Gas Sensor Module Gas Sensor List
SP 2nd is an economical gas detector that can be operated continuously for two years without replacement of gas sensor to protect workers from the disasters caused by the oxygen deficiency or toxic gas poisoning. Measure one gas continuously and display its concentration and raise an alarm when a risk occurs.
SP 12C7 is an united gas detector measuring four (4) major gases, which result the most of the industrial accidents, to protect workers from the disasters caused by the oxygen deficiency , toxic gas poisoning and gas explosion. Measure continuously four (4) gases (O2, CO, H2S and CH4) and display their concentrations and raise an alarm when the risk occurs. SP 12C7 is provided with stationary type charger as a basic package for the conveniences in use and alkaline battery pack is also provided as a basic for emergency use.
Specification
MODEL
Detecting Gas Detecting Range Sensor Type Sampling Method Display Audible Alarm Visual Alarm Vibrator Alarm Power Operating temp. & Humi. Explosion proof Case Standard Accessories Option Dimension Weight
SP2217
O2 0~30%
SP2227
CO 0~1000ppm
SP2257
SO2 0~100ppm Electrochemical Diffusion Digital LCD 90dB Red LED & White back light Vibrator CR2 battery
SP2277
H2 0~1000ppm
SP2297
H2S 0~200ppm
Specification
MODEL
Detecting Gas Detecting Range Sensor Type Sampling Method Display Audible Alarm Visual Alarm Vibrator Alarm Power Operating temp. & Humi. Explosion proof Case Water/Explosion proof Option Dimension Weight O2 0~30% Galvanic CO 0~1000ppm Electrochemical Diffusion Digital LCD 90dB Red LED & White back light Vibrator Rechargeable NI-MH battery pack , Alkaline battery 2ea -20 ~ +50, : 10% ~ 95% RH (non-condensing) EEx ia IIC T4 Clear polycarbonate with thermal-plastic elastic(TPE) over mold : II1G Ex ia IIC T4 IP67 External pump 54(W) x 135(H) x 36.5 (D)mm 240g
7
SP12C7
H2S 0~200ppm Electrochemical EX 0~100%LEL Catalytic
-20 ~ +50, : 10% ~ 95% RH (non - condensing) : II1G Ex ia IIC T4 IP67 Clear polycarbonate with thermal-plasticelastic (TPE) overmold. Belt Clip, Calibration Cap Pump for gas sampling 54(W) x 91(H) x 32(D)mm 120g(with battery)
Sampling pump is designed to be used by connecting to SP 12C7 and SP 2nd model. Can be used to check if there is gas leakage when measure the gas underground manhole.
are compatible
Specification
Power Operating time Operating temp. & Humi. Sampling flowrate Self Checking Dimensions Weight AA size Alkaline battery 1ea More than 5 hours -20 ~ + 50, 0 to 95% RH 0.5 liter / min Low flow alarm, Low battery alarm (Red LED) 34(W) 270(H) 47 (D)mm 200g (with battery)
SP secure LEL is designed to be suitable for leak detection of combustible gases from pipes, valves and any joint automatic gas sampling. Since the measured gas concentration is displayed in digital number, accurate measurement is possible.
Specification
MODEL SP Secure LEL
methane, propane Internal sampling pump, flow rate 0.5 liter/min. Catalytic 0 ~ 100%LEL 5 seconds 50ppm Digital LCD (Alarm, Buzzer, Pump On-off and battery status) Buzzer alarm and LCD display 0~1% LEL digital bar 1~100% LEL numerical display Sensor : EX d IIC T6 Detector : EX ia IIC T4 -20 ~ 50 Recharger or AA Alkaline battery 3ea More than 12 hours 55m(W) x 241mm(H) x 33 mm(D) 260g Extension Probe and charger adapter Detecting Gas Sampling method Sensor type Detecting range Response time Resolution Display Alarm Gas concentration display Explosion Proof Operating temperature
Specification
Power Operating time Operating temp. & Humi. Dimensions Weight DC 10~32V MAX 1A NI-MH battery -20 ~ + 50, 0 to 95% RH 106mm(W) x 85.5mm(H) x 115 mm(D) 190g
flammable gas, toxic gas, oxygen and display with LCD Easy magnetic bar operation Big digital LCD installed with a blue backlight Explosive proof structure Water/dust proof structure Simple gas calibration
SP securePlus is designed to be suitable for leak detection of any gas piping and valves by equipping a built-in sampling pump. Since the measured gas concentration is displayed in digital number, accurate measurement is possible.
SI-100 is a fixed gas detector installed in a place where potential gas hazard exists to measure oxygen, toxic gas and combustible gas. It shows not only the concentration of gas but also diagnostic result of the unit itself through the LCD display and can be connected to the controller with a standard 4-20mA analog output communication or RS-485 digital communication.
Specification
MODEL
Detecting Gas Sensor type Sampling method Resolution Response time Resolution Display Alarm Gas concentration display Explosion Proof Operating temperature Power Operating time Dimension/ weight Options
SP SecurePlus
Hydrogen, Xylene etc. Electrochemical, IR etc. Internal sampling pump, flow rate 0.5 liter/min Depend on sensor type Depend on sensor type Depend on sensor type Digital LCD (Alarm, Buzzer, pump on-off and battery status) Buzzer alarm and LCD display Low concentration : digital bar High concentration : numerical display Ex ia II C T4 - 20C ~ 50C Recharger or AA Alkaline battery 3ea Depend on sensor type, 12 ~ 24 hours 55m(W) x 241mm(H) x33 mm(D) / 260g Extension probe
Specification
MODEL
Sampling Method Measuring value display Detecting gas Sensor type Detecting range Accuracy Setting & control Alarm signal Output signal Telemetering line length Operating temp. & Humi. Power Dimensions Weight Explosion Proof Combustible Gas Catalytic 0 - 100% LEL IR 0 - 100% LEL
SI-100
Diffusion Type Digital LCD (Blue Backlight) Toxic Gas Electrochemical Refer to page 23 3% / Full Scale Magnetic interface to configure alarm & calibrations 1st alarm, 2nd alarm, Relay contact (30V, 2A) Analog : 4-20mA Digital : RS-485 Modbus Analog output MAX. 2,500m Digital output MAX. 1,000m -20 to 50 : 10 to 95% RH (Non - condensing) 10~30V DC 150(W) 165(H) 110(D)mm 1.8 kg Ex d IIC T5, IP65
11
10
Connecting controller with a fixed gas detector, you can control gas detectors outside of hazardous place. Single or multi-channel controller is available.
Specification
MODEL
Operate display Concentration display Detecting range Alarm Alarm output signal Alarm level set Input signal Output signal Alarm recover
Confined space
Wireless O2 detector
ZIGBEE communication
Multi-channel Controller
SI-COMMON UNIT SI-CHANNEL UNIT
Zone 1
Zone 2 Wireless repeater Wireless O2 detector Wireless O2 detector Confined space Wireless O2 detector Wireless repeater DB server Integration Control server
L3 B/B S/W
Confined space
LEDs (Power, 3-alarm, Trouble Buz. Stop, LEDs (Power, 3-alarm, Trouble) PC communications, channel Stand-by(test) communications) 4-Digit FND & Bar-Graph Refer to page 23 (%LEL, ppm, % Vol) Power, Alarm, sensor fail LEDs Buzzer( Audible alarm) Concentrations alarm, Trouble Alarm AC250V/5A relay contact 3-Alarm, Trouble LEDs Concentrations Alarm, Trouble Alarm AC250V/5A relay contact Programmable within detection range 4 - 20mA DC (2 wire or 3 wire) RS - 485 Modbus(option) Reset switch & PC control 4 - 20mA DC Reset switch Alarm value & type (1, 2, 3 alarm) Alarm time (instant & delay (1~30 min)) Alarm dead band Relay output on/off -20 ~ +50, 0 ~ 99%.RH (non - condensing) AC 110 / 220V 24V DC / 600mA, 1300mA (option) Backup UNIT (option)
Backup server
ZIGBEE communication
Environment sensor node
Installation Picture
O2 Monitoring
Administrator 1
Administrator 2
Specification
Applications
Wireless monitoring system for protect from industrial gas accident. Wireless monitoring system to control a working environment Oxygen monitoring system to prevent death from suffocation The leakage of gas pipe line monitoring system Gas monitoring system in mines IAQ monitoring system for Green Building Ocean's environment monitoring system Pollution (DO, pH, etc) of river monitoring system Air quality monitoring system in public spaces (theater, hospital etc) Air quality monitoring system of the underground station Gas monitoring system of tunnel
Industrial Safety
Public spaces
12
13
The calibration function of each gas sensor The data memory function with SD card installed inside of
odor detector
Index
ARM Memory Serial USB WLAN
Specifications
S3C6410 (633MHz) DDR2 SDRAM 128 MB(533MHz) 64 MB NAND Flash (Max 1GB) 3 port (include console 1 port) High speed USB 2.0 2 port (host controller) USB I/F Wireless-LAN Module USB / RS 232c interface 5.7 Graphic LCD, 1024x768 1GB or 2GB Linux kernel 2.6 version Serial sensor I/F TCP transfer socket program LCD Display Qt program USB WLAN Serial I/F CDMA
H/W
Adjustable with the customer requirement Adjustable with the customer requirement 220V Power supply or Solar cell power supply Reflection of legal odor category 422Mhz, 2.4Ghz radio frequency Power supply check lamp Water/Dust proof structure and corrosion proof material Amemovane (automatically work when it is connected) S/W
APPLICATION IMAGE
14
15
required Economic system which doesn't require any wiring construction Explosion proof structure Water/Dust proof structure Same functions with Fixed Gas Detector working with wiring electrical power source Tracking is possible with its own address Maintenance and Replacement are simple
Features
Display combustible gas concentration as
%LEL Easy to operate High audible buzzer alarm Self diagnostic function Relay output for an extra alarm, shut-off valve etc.
Controller
Specification
MODEL
Measuring type Measuring value display Detecting gas Sensor type Detecting range Accuracy Setting & control Communication length among sensor nodes Operating temp. & Humi. Power and battery life time Radio Frequency Dimensions Weight Explosion Proof
16
SL-101
Diffusion Type Digital LCD Combustible Gas Catalytic 0 - 100% LEL IR 0 - 100% LEL Toxic Gas Electrochemical Refer to page 23 3% / Full Scale Setting from control center or site(field) MAX. 300m -20 to 50 : 5 to 95% RH (Non-condensing) 3.6V battery 4ea / more than 6~12 months (IR or Catalytic need regular power) 433MHz, 914MHz, 2.45GHzg 150(W) 165(H) 110(D)mm 1.8 kg Ex d IIC T5, IP65 Oxygen Galvanic 0 - 30% Volume
SI-560 is a simple combustible gas detector consisted of sensing unit and controller. As a gas detector installed around the piping or valves where the risk of gas leak exist, this is an entry-level product of modest price.
Specification
MODEL
Detecting gas Detecting range Sensor type Sampling method Response time Accuracy Power Output Operating temp. & Humi. Explosion proof Dimensions Weight
SI560
methane/propane 0~100% LEL Catalytic Diffusion 15 sec / T90 3% / Full Scale 18~31V DC (24V DC normal) 4 - 20mA -20 ~ +50 : 0% ~ 95% RH (non - condensing) Ex d IIB T4 130mm(W) 107mm(H) 73mm(D) 0.6 kg
17
Gas Detector & Shut-Off Valve For Home Safety (SH 1362 SET)
Features
Gas monitoring system for home safety composed of gas alarm, controller and shutoff Device. If the gas is leaked from the gas valve or gas pipe, the gas detector detects gas leaks and sends the signal to the controller. The controller exams the signal and then send again to the shutoff device, and finally shutoff device operate to close the gas valve to prevent gas explosion.
SH1362
SH1362C
SH1362S
monoxide(CO) poisoned Indirect and simple instrument to measure carboxyhemoglobin(COHb) in blood Easy to discriminate smoker Easy to recognize the degree of CO poisoning (smoking habit) Two language (English, Korean) are provided CE certificate of European medical equipment Concentration of CO in breath and percentage of COHb in blood are displayed simultaneously Adult/Pregnant/Young mode are provided
Specification
MODEL
Power Detecting gas Detecting indication Alarm concentrations Power consumption Alarm output Operating temp. & humi. Dimensions Weight
SH1362
DC12V 20% LPG, LNG Flashing Yellow LED and Buzzer LPG(600ppm ~ 4,500ppm) LNG(600ppm ~ 12,500ppm) 1.3W DC 8V ~ 12V(when it is alarming) -20C ~ 50C / 0% ~ 95%RH 85 75 30 mm 80g
Specification
Detecting range Sensor type Accuracy Sensor drift Cross sensitivity (Hydrogen) Sensor life time Resolution Calibration User mode Countdown Sound Operating Temp. & Humi. Mouthpiece adapter LCD size LED indicator COHb% Power Dimensions Weight Disposable mouthpieces 0~100ppm or 0~500ppm Electrochemical 2% or 1ppm/ month 1% / month 5~10% 2~5years (max. 5 years) 1ppm Zero / span Adult / Adolescent 15 seconds On / Off 0 ~ 40/5~95% D type bacteria filter 50x30mm 7 steps (Green/amber/red) LCD display AAAlkaline battery 2ea 70 150 32mm 160g 22mm
19
MODEL
Power Operating Shut-off time Open/close indicator Gas leak indicator Dimensions Weight
SH1362C
AC 220V, 50/60Hz Automatic signal control/manual shut off control/manual return 15 ~ 25 seconds Open lamp (green LED) Close lamp (yellow LED Flashing yellow & Buzzer 75 105 45 mm 350g
MODEL
Power Operating Dimension Weight
18
SH1362S
DC 12V Automatic, Manual 60 130 150 mm 350g
Gas Sensor
Oxygen sensor SS1118 (0~100%)
With high concentrated oxygen measuring sensor, only for the Oxygen generator and medical sensor Measure the oxygen's pressure in the air
sthemeasuringsensoroftheoxygeninthe A air, suitable for the portable equipment and industrial equipment Excellent accuracy and response time
Specification
MODEL
Detecting Gas Nominal Range Maximum Overload Expected Operating Life (years) Output Signa Resolution Temperature Range Pressure Range T90 Response Time Relative Humidity Range Typical Baseline Rang Maximum Zero Shift (+20 to +40) Long Term Output Drift Recommended LoadResistor Bias Voltage Repeatability Output Linearity Weight Position Sensitivity Storage Life Recommended Storage Temperature Warranty Period 2 years 2 years 2 years 7g 18g 6g 15 sec 15 sec 15 sec
Fire monitoring application for the portable equipment, industrial safety equipment, boiler room, parking place Excellent stability of the output signal and little affected by other gases
SS1118
Oxygen 0~100% 18 month 6.01.0mV 0.1% -10to50
SS2118
Oxygen 0~30% 2 9020@ /20.9%Oxygen 0.1%
SS1128
Carbon monoxide 0~1,000ppm 2,000ppm 2 6015nA/ ppm 1ppm
SS1198
Hydrogen sulfide 0~500ppm 1,000ppm 2 0.600.15 /ppm 0.1ppm
SS1178
Hydrogen 0~1,000ppm 2,000ppm 2 1510/ppm 2ppm
SS11N8
Ammonia 0~50ppm 200ppm 2 10020nA /ppm 0.5ppm
IRsenor
Hydro Carbon, CO2 etc 0-5% Vol. 0-100% 5 0-2.8V DC 0.5% -20~50
Suitable to monitor the power plant, hydrogen fuel battery, hydrogen tank, hydrogen leakage and processes Minimize the interference on the hydrogen sulfide
30 sec 0~90%RH
15~90%RH Less than 5%/year Not required 2% of signa Less than 5%/year 100 Not required 2% of signa -2 to 3ppm -2 to 3ppm Less than 5%/year 10 Not required 2% of signa -0.1 to 0.5ppm 0.2ppm equivalent Less than 5%/year 10 Not required 2% of signa Linear 6g None 6 month 0~20 2 years 2 years 1 years 6g 6g 0 to 30ppm -20ppm equivalent Less than 5%/month 10 Not required 2% of signa 0 to 10ppm 10ppm equivalent Less than 10%/month 10 +0.3V Bias 10% of signal
Suitable to monitor the livestock waste, food decay, ammonia leak, and processes Comparing the competitor's product, much faster response
IR sensor
Gas measuring Sensor only for the flammable gas and carbon dioxide, nitrogen dioxide The Infrared sensor which has Very fast response and excellent accuracy can measure the flammable gas in the nonoxygen space
20
2 years 21
Detecting range
0-30% 0-1,000ppm 0-500ppm 0-20ppm 0-1,000ppm 0-50ppm 0-100ppm 0-30ppm 0-100ppm 0-2ppm 0-1,000ppm 0-150ppm 0-20ppm 0-50ppm 0-15,000ppm
Sampling method
Permissible Standards
LEL(%Vol)
12.5 4.3 4% vol 15 5.6 1 1.35 1.86 3.00 3.60 2.75 3.00 1.20 5.00 10.00 1.5 2.20
Specific Gravify
1.11 0.968 1.19 2.26 10.07 0.6 2.49 1.27 0.941 1.65 1.53 1.58 1.18 1.11 1.5 2.00 1.00 1.60 1.00 1.50 3.50 0.55 3.30 1.53 2.5 1.50
Electrochemical 19.5%-23.5% Electrochemical Electrochemical Electrochemical Electrochemical Electrochemical Electrochemical Electrochemical Electrochemical Electrochemical Electrochemical Electrochemical Electrochemical Electrochemical NDIR 0-500ppm up to 0-5% Vol IR IR IR IR IR IR IR IR IR IR IR IR 5000ppm 50ppm 25ppm 10ppm 2ppm 25ppm 1ppm 5ppm 10ppm 0.1ppm 25ppm 3ppm 0.3ppm 5ppm
Specification
Sensor type
Sensor type Operating temp. Sensitivity Cost Power consumption Applications Detecting gases
C2H6
Electrochemical
-20~50 High High Expensive Low Industrial safety/ Environment O2, CO, H2S, SO2 etc.
Metal oxide
0~60 High High Cheap
Optical
-20~50 Medium Medium Expensive Moderate
Catalytic
-30~150 Medium Medium Medium Moderate Flammable /Combustible gas CH4, C3H8