CIDCO OF MAHARASHTRA LTD C.A.No.

36/CIDCO/EE(Elect)/2010-11

Sr. Page No.

CODES AND STANDARDS


The following codes and standards shall be applicable for continuous performance of all electrical equipments to be supplied, delivered at site, erected, tested and commissioning. The electrical equipments offered shall comply to the relevant Fire Insurance Regulations, Tariff Advisory Indian Standards Specifications. all its latest amendments upto date. For guidelines to the tenderers, few of the Indian Standards are indicated below :1. 2. 3. 4. 5. IS:116 IS:159 IS:3043 IS:10116 IS:10116 Circuit breakers for AC System. Bubars and Busbars connections. Code of practice of earthing.

Committee Regulations, and particular to Indian Electricity Rules in all respect with

Code of practice for installation of switchgear. Code of practice for selection, installation and maintenance of fuse (upto 650 Volts.) Potential Transformers. Climate proofing of electrical equipments. Metal enclosed switchgear and central gear. Specification for fittings for rigid PVC non-metallic conduit. Gas separated relays. Fittings and accessories for power

6. 7. 8. 9. 10. 11.

IS:3165 IS:3203 IS:3427 IS:3419 IS:3537 IS:3639

CIDCO OF MAHARASHTRA LTD C.A.No.36/CIDCO/EE(Elect)/2010-11

Sr. Page No.

12. 13.

IS:3837 IS:4064

Transformer. Accessories for rigid steel conduits. Heavy duty Air Break switches and composite. Switch fuse units for voltage and exceeding 100V. Switch fuse units for Industries etc. General requirements for switchgears not exceeding 1000 Volts. Switch socket outlet. Sheet steel boxed. Lighting Are stores. L.T. capacitors. Electric power switchgear for indoor and outdoor installation. Circuit Breakers. Specification for conduits for electrical installation. for H.T. insulator of 33KV grade and above. Insulating Transformer Oil. Ceiling fans. Marking and arrangement for switchgear boards main connections auxiliary wiring Tungsten filament lamps. Paper insulated cables. PVC insulated cables and cords for

14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29.

IS:4064 IS:4237 IS:4615 IS:5133 (Part-I) IS:3070 (Part-I) IS:2034 IS:192 IS:PUB 26 IS:9535

IS:240 (Part-I & II) IS:335 IS:374 IS:375 IS:415 IS:692 IS:694 -

CIDCO OF MAHARASHTRA LTD C.A.No.36/CIDCO/EE(Elect)/2010-11 power lighting. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. IS:722 IS:732 IS:1087 IS:1248 IS:1255 IS:1293 IS:1554 IS:1567 IS:1651 IS:1653 IS:1771 IS:6600 IS:6946 IS:7098 (Part-II) IS:5216 IS:5578 -

Sr. Page No.

Three phase watt hour meters with MDI Electrical wiring installation (upto 650V) Single pole tumbler switch 5 Amps. Direct reading electrical indicating instruments. installation and maintenance of paper insulated power cables upto 33 KV) 3 Pin lugs and sockets outlets. PVC insulated cables heavy duty. Metal clad switches upto 100 Amps. Lead acid cell batteries. Rigid steel conduits for electric wiring. Industrial light fittings with accessories. Loading of oil immersed transformer. Reliable (flexible) non-metallic conduits for electrical. For XLPE type cables. Guide for safely procedure and practices in electric work. Guide for marking of insulated conductors. 11 kv drop out fuses. Pre-cast concrete cables covers.

46. 47.

IS: 5792 IS:5820

CIDCO OF MAHARASHTRA LTD C.A.No.36/CIDCO/EE(Elect)/2010-11

Sr. Page No.

48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63.

IS:5908 IS:6381 IS:1818 IS:1886 IS:1947 IS:2026 IS:9242 IS:9242 IS:2251 IS:2268 IS:2274 IS:3854 IS:2312 IS:2309 IS:2418 IS:2544

Method of measurement of electrical installation in building. Specifications for construction and testing of electrical apparatus. Isolation and earthing switches.

Code practice for installation of transformers. Flood lights. Transformers. Degree of protection provided for enclosure for switchgear. HRS cartridge fuse units upto 650 Volts. Code of practice for Danger Notice Plates. Code bell/buzzers. Code of practice for wiring installation (exceeding 650 Volts) Switches for domestic and similar purpose. Exhaust fans. Code of practice for lighting protection. Tubular fluorescent lamps for general lighting service. Porcelain post top insulators for BBW Class.

CIDCO OF MAHARASHTRA LTD C.A.No.36/CIDCO/EE(Elect)/2010-11 64. 65. 66. 67. 68. 69. 70. IS:2509 IS:2516 IS:2667 IS:2692 IS:2575 IS:2705 IS 14930 II -

Sr. Page No.

PVC electrical conduits. A.C. Circuit breakers. Fittings for rigid steel conduits for electrical wiring. 11 KV drop out fuses. Enclosed distribution fuse boards and cutouts for voltage upto 1000 V. Current transformer. Double Walled Corrugated pipes of High Density Polyethylene (HDPE) with couplings, tees, sockets for cable protection.

The entire electrical installation work shall be strictly complied with the codes, standards, rules and regulations framed under the Indian Electricity Act. Further it shall be strictly carried out as per the regulations and rules set out by Tariff Advisory Committee and/or Fire Insurance Regulations. Some of the rules framed under the Indian Electricity Rules, 1956 and all amendments thereof more particularly complied to : 35, 43, 44, 44-A, 45 (Part), 50, 51, 59, 61 (a), 61 (c), 62, 63 (2), 65, 66, 67, 68, 69 and 92(2).

_______________________ Stamp and signature of Contractor Date :

________________________________ Executive Engineer (Electrical) Date :