MICRO CONFIGURATIONS AND FUNCTIONS

SUPRA
Supra 4XX MICRO configuration

Description
Soft 3.31 TV OFF OFF OFF OFF GLOW TIME DI Engine long glow cycle Indicates to the control which engine is in the system and which glow time should be TV Engine short glow cycle DISCHARGE SENSOR CDT not used Indicates to the control if the DISCHARGE sensor is installed CDT used HIGH SETPOINT 30c (86F) Max. Set point Indicates maximum Set Point allowed 32c (90F) Max. Set point HEAT LOCKOUT OVERRIDE (Truck unit) Heat lockout on -12c (10F) Indicates to the control if the heat lockout is overridden Heat lockout off MOP MOP disabled Indicates status of MOP control MOP enabled TRUCK UNIT Trailer unit Indicates to the control if the system has been selected for truck operation Truck unit HIGH SPEED OVERRIDE High speed start Indicates to the control if lock in high speed start Low speed start ELECTRIC FAN Belt driven fan Indicates to the control if electric fans are being used Electrical fan motors OUT-OF-RANGE SHUT DOWN Out of range alarm only Indicates if main compartment out-of-range alarm shuts unit down after 45min. Out of range alarm and unit shut down TRUCK AUTO-RESTART OPTION No auto restart Indicates if diesel restart after AC power loss function is active Auto restart active if FN6=Time start FUNCTIONAL PARAMETERS (KEYPAD) LOCKOUT OPTION Functions normal Allow or lockout certain any changes of the functional parameter from keypad Functions locked HP-62 MOP OPTION MOP parameter HP 62 option Use either normal or HP-62 MOP parameters Active HEAT ONLY UNIT OPERATION OPTION Normal cool / heat / defrost operation Converts unit to a "Heat only" unit Heat only operation (Solara) INVERTABLE MULTI TEMP Not active Indicates to the control if reversible multi temp control is active Reversible multi-temp active DIESEL / ELECTRIC STANDBY (Truck unit) Truck with Diesel & electrical standby Indicates to the control if the truck is diesel only Truck diesel only SHUNT DOWN WITH ALTERNATOR AUX ALARM Alt aux alarm only Indicates if alternator AUX alarm shuts unit down in diesel mode Alt aux alarm & unit shut down ULTRA FREEZE 1 OPERATION Disable Ultra freeze 1 Indicates to the control if UFZ1 operation can run Enable Ultra freeze 1 LOW REFRIGERANT TEST Disable low refrigerrant test Indicates to the control if low refrigerant test is enable Enable low refrigerrant test SIROCCO UNIT Supra unit Indicates if the unit is Sirocco unit Sirocco unit UNITS SELECTION LOCK OPTION Metric unit or english metric is not locked Indicates to the control if the units functional parameter is locked Unit selection is locked FROZEN MODE PRIORITY LOGIC OPTION Frozen priority not active Enables frozen priority logic Active NOT CURRENTLY ASSIGNED Not used Not used SET POINT LOCK Set Point is not locked Indicates if the change of the Set Point is locked Set Point is locked WT SENSOR ALARM (Truck unit) WT sensor alarm only Indicates if WT sensor alarm shuts unit down WT sensor alarm & unit shut down Not used DI TV OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF

Supra 4XX Nordic 3.31 TV OFF OFF

Supra 5XX 3.31 TV ON OFF OFF

Supra 5XX Nordic 3.31 TV ON OFF

OASIS 150 3.31 TV OFF OFF OFF

Supra 7XX 3.31 TV ON OFF OFF OFF

Supra 7XX Nordic 3.31 TV ON OFF

OASIS 250 3.31 TV ON OFF OFF

750sw 3.31 TV ON OFF OFF OFF

750sw Nordic 3.31 TV ON OFF

Supra 8XX 3.31 TV OFF OFF OFF

Supra 8XX Nordic 3.31 TV OFF OFF

Supra 9XX 3.31 TV ON OFF OFF

Supra 9XX Nordic 3.31 TV ON OFF

OASIS 350 3.31 TV ON OFF OFF

CNF1: choix(DI/TV) CNF2 : choix (ON/OFF) CNF3 : choix (ON/OFF) CNF4 : choix (ON/OFF) CNF5 : choix (ON/OFF) CNF6 : choix (ON/OFF) CNF7 : choix (ON/OFF) CNF8 : choix (ON/OFF) CNF9 : choix (ON/OFF) CNF10 : choix (ON/OFF) CNF11 : choix (ON/OFF) CNF12 : choix (ON/OFF) CNF13 : choix (ON/OFF) CNF14 : choix (ON/OFF) CNF15 : choix (ON/OFF) CNF16 : choix (ON/OFF) CNF 17 : choix (ON/OFF) CNF 18 : choix (ON/OFF) CNF 19 : choix (ON/OFF) CNF 20 : choix (ON/OFF) CNF 21 : choix (ON/OFF) CNF 22 : choix (ON/OFF) CNF 23 : choix (ON/OFF) CNF 24 : choix (ON/OFF)

ON OFF

OFF

ON OFF

OFF

ON OFF

OFF

ON OFF

OFF

ON OFF ON

ON ON ON OFF ON ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

CNF 25 to CNF 32 : choix (ON/OFF)

FN0 FN1 FN2 FN3 FN4 FN5 FN6 FN7 FN8 FN9 FN10 FN11 Affichage display Manuel glow override Alarm reset

Defrost setting : 1,5;3;6;12h ON/OFF Air On = high/Off=Norm Off time choice : 10;20;30;45;90mn On time choice 4;7 A/B PROBE choice A=Rem/B=Sup F/C degree choix : F or C On=time start/ Off=temp start MOP choice : STD=0/-=-5/+=+4 2SET Set point adjustment 2CP 3SET Set point adjustment 3CP Start Op choice : on=Auto/off=Man T range choix A=2, B=3, C=4 Dreg C T Range choix : CODES OU ENGLISH choice NORM / ADD CLR/RST

3h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

3h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

Micro parameters 3h 3h OFF=Norm air OFF=Norm air 20 mn 20 mn 7 mn 7 mn A=Rem probe A=Rem probe deg C deg C OFF=Temp strt OFF=Temp strt STD=0 STD=0 Sans Sans Sans Sans On = Auto OP On = Auto OP C C English English Norm Glow Norm Glow CLR CLR

3h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

6h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

6h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

6h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

6h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

6h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

6h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

6h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

3h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

3h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

3h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

Update 22/02/2008

MICRO CONFIGURATIONS AND FUNCTIONS

SUPRA MT
Description MICRO configuration Soft CNF1: choix(DI/TV) CNF2 : choix (ON/OFF) CNF3 : choix (ON/OFF) CNF4 : choix (ON/OFF) CNF5 : choix (ON/OFF) CNF6 : choix (ON/OFF) CNF7 : choix (ON/OFF) CNF8 : choix (ON/OFF) CNF9 : choix (ON/OFF) CNF10 : choix (ON/OFF) CNF11 : choix (ON/OFF) CNF12 : choix (ON/OFF) CNF13 : choix (ON/OFF) CNF14 : choix (ON/OFF) CNF15 : choix (ON/OFF) CNF16 : choix (ON/OFF) CNF17 to CNF32 : choix (ON/OFF) DI TV OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON DI Engine long glow cycle TV Engine short glow cycle CDT not used CDT used 30c (86F) Max. Set point 32c (90F) Max. Set point Heat lockout on -12c (10F) Heat lockout off (trailor units) Frozen priority not active Active Trailer unit Truck unit Low speed start High speed start Belt driven fan Electrical fan motors Out of range alarm not shut down Out of range alarm and unit shut down No auto restart Auto restart active if FN5=Time start Functions normal Functions locked Low Oil Level Alarm Active Disable low refrigerant test Enable low refrigerant test Not active Not active Alt aux alarm only Alt aux alarm & unit shut down 4.05 TV ON OFF OFF 4.05 TV ON OFF OFF 4.05 TV ON OFF OFF 4.05 TV ON OFF OFF 4.05 TV OFF OFF OFF 4.05 TV ON OFF OFF 4.05 TV ON OFF OFF R90U R90 S750MT OASIS 250MT S850MT 950MT 950UMT

ON ON OFF

ON ON OFF

ON ON OFF

ON ON OFF

ON ON OFF

ON ON OFF

ON ON OFF

ON OFF OFF OFF OFF

ON OFF OFF OFF OFF

ON OFF OFF OFF OFF

ON OFF OFF OFF OFF

ON OFF OFF OFF OFF

ON OFF OFF OFF OFF

ON OFF OFF OFF OFF

ON OFF OFF

ON OFF OFF

ON OFF OFF

ON OFF OFF

ON OFF OFF

ON OFF OFF

ON OFF OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

FN0 FN1 FN2 FN3 FN4 FN5 FN6 FN7 FN8 Affichage display Manuel glow override Alarm reset

Defrost setting : 1,5;3;6;12h ON/OFF Air On = high/Off=Norm Off time choice : 10;20;30;45;90mn On time choice 4;7 F/C degree choix : F or C On=time start/ Off=temp start MOP choice : STD=0/-=-5/+=+4 Start Op choice : on=Auto/off=Man T range choix A=2, B=3, C=4 Dreg C CODES OR ENGLISH Display choice NORM / ADD CLR/RST

Micro parameters 3H 3H OFF=Norm air OFF=Norm air 20 mn 20 mn 7 mn 7 mn Deg C Deg C OFF=temp strt OFF=temp strt STD=0 STD=0 ON=Auto OP ON=Auto OP C C English English Norm Glow Norm Glow CLR CLR

3H OFF=Norm air 10 mn 7 mn Deg C OFF=temp strt STD=0 ON=Auto OP C English Norm Glow CLR

3H OFF=Norm air 10 mn 7 mn Deg C OFF=temp strt STD=0 ON=Auto OP C English Norm Glow CLR

3H OFF=Norm air 10 mn 7 mn Deg C OFF=temp strt -5 ON=Auto OP C English Norm Glow CLR

3H OFF=Norm air 10 mn 7 mn Deg C OFF=temp strt STD=0 ON=Auto OP C English Norm Glow CLR

3H OFF=Norm air 20 mn 7 mn Deg C OFF=temp strt STD=0 ON=Auto OP C English Norm Glow CLR

Update 22/02/2008

MICRO CONFIGURATIONS AND FUNCTIONS

UNDERMOUNT
Supra 944U MICRO configuration Supra 988U 3.31 TV ON OFF OFF Supra 950U 3.31 TV ON OFF OFF Supra 850U 3.31 TV OFF OFF OFF OFF ON ON OFF ON ON OFF ON ON OFF ON OFF

Description
Soft 3.31 TV ON OFF OFF GLOW TIME Indicates to the control which engine is in the system and which glow time should be DISCHARGE SENSOR Indicates to the control if the DISCHARGE sensor is installed HIGH SETPOINT Indicates maximum Set Point allowed HEAT LOCKOUT OVERRIDE (Truck unit) Indicates to the control if the heat lockout is overridden MOP Indicates status of MOP control TRUCK UNIT Indicates to the control if the system has been selected for truck operation HIGH SPEED OVERRIDE Indicates to the control if lock in high speed start ELECTRIC FAN Indicates to the control if electric fans are being used OUT-OF-RANGE SHUT DOWN Indicates if main compartment out-of-range alarm shuts unit down after 45min TRUCK AUTO-RESTART OPTION Indicates if diesel restart after AC power loss function is active FUNCTIONAL PARAMETERS (KEYPAD) LOCKOUT OPTION Allow or lockout certain any changes of the functional parameter from keypad HP-62 MOP OPTION Use either normal or HP-62 MOP parameters HEAT ONLY UNIT OPERATION OPTION Converts unit to a "Heat only" unit INVERTABLE MULTI TEMP Indicates to the control if reversible multi temp control is active DIESEL / ELECTRIC STANDBY (Truck unit) Indicates to the control if the truck is diesel only SHUNT DOWN WITH ALTERNATOR AUX ALARM Indicates if alternator AUX alarm shuts unit down in diesel mode ULTRA FREEZE 1 OPERATION Indicates to the control if UFZ1 operation can run LOW REFRIGERANT TEST Indicates to the control if low refrigerant test is enable SIROCCO UNIT Indicates if the unit is Sirocco unit UNITS SELECTION LOCK OPTION Indicates to the control if the units functional parameter is locked FROZEN MODE PRIORITY LOGIC OPTION Enables frozen priority logic NOT CURRENTLY ASSIGNED DI Engine long glow cycle TV Engine short glow cycle CDT not used CDT used 30c (86F) Max. Set point 32c (90F) Max. Set point Heat lockout on -12c (10F) Heat lockout off MOP disabled MOP enabled Trailer unit Truck unit High speed start Low speed start Belt driven fan Electrical fan motors Out of range alarm only Out of range alarm and unit shut down No auto restart Auto restart active if FN6=Time start Functions normal Functions locked MOP parameter HP 62 option Active Normal cool / heat / defrost operation Heat only operation (Solara) Not active Reversible multi-temp active Truck with Diesel & electrical standby Truck diesel only Alt aux alarm only Alt aux alarm & unit shut down Disable Ultra freeze 1 Enable Ultra freeze 1 Disable low refrigerrant test Enable low refrigerrant test Supra unit Sirocco unit Metric unit or english metric is not locked Unit selection is locked Frozen priority not active Active Not used Not used Set Point is not locked Set Point is locked WT sensor alarm only WT sensor alarm & unit shut down OFF Micro parameters Defrost setting : 1,5;3;6;12h ON/OFF Air On = high/Off=Norm Off time choice : 10;20;30;45;90mn On time choice 4;7 A/B PROBE choice A=Rem/B=Sup F/C degree choix : F or C On=time start/ Off=temp start MOP choice : STD=0/-=-5/+=+4 2SET Set point adjustment 2CP 3SET Set point adjustment 3CP Start Op choice : on=Auto/off=Man T range choix A=2, B=3, C=4 Dreg C T Range choix : CODES OU ENGLISH choice NORM / ADD CLR/RST DI TV OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON Not used

CNF1: choix(DI/TV) CNF2 : choix (ON/OFF) CNF3 : choix (ON/OFF) CNF4 : choix (ON/OFF) CNF5 : choix (ON/OFF) CNF6 : choix (ON/OFF) CNF7 : choix (ON/OFF) CNF8 : choix (ON/OFF) CNF9 : choix (ON/OFF) CNF10 : choix (ON/OFF) CNF11 : choix (ON/OFF) CNF12 : choix (ON/OFF) CNF13 : choix (ON/OFF) CNF14 : choix (ON/OFF) CNF15 : choix (ON/OFF) CNF16 : choix (ON/OFF) CNF 17 : choix (ON/OFF) CNF18 : choix (ON/OFF) CNF19 : choix (ON/OFF) CNF 20 : choix (ON/OFF) CNF 21 : choix (ON/OFF) CNF 22 : choix (ON/OFF) CNF 23 : choix (ON/OFF)

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF OFF OFF OFF OFF OFF OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

ON METRIC OFF OFF OFF

SET POINT LOCK Indicates if the change of the Set Point is locked WT SENSOR ALARM (Truck unit) CNF 24 : choix (ON/OFF) Indicates if WT sensor alarm shuts unit down

ON OFF

ON OFF

ON OFF

ON OFF

CNF 25 to CNF 32 : choix (ON/OFF)

FN0 FN1 FN2 FN3 FN4 FN5 FN6 FN7 FN8 FN9 FN10 FN11 Affichage display Manuel glow override Alarm reset

3h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

3h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

3h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

6h OFF=Norm air 20 mn 7 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow CLR

Update 22/02/2008

MICRO CONFIGURATIONS AND FUNCTIONS

MAXIMA
MICRO configuration GLOW TIME CNF1: choix(DI/TV) Indicates to the control which engine is in the system and which glow time should be DISCHARGE SENSOR CNF2 : choix (ON/OFF) Indicates to the control if the DISCHARGE sensor is installed HIGH SETPOINT CNF3 : choix (ON/OFF) Indicates maximum Set Point allowed HEAT LOCKOUT OVERRIDE (Maxima MT Only) CNF4 : choix (ON/OFF) Indicates to the control if the heat lockout is overridden MOP CNF5 : choix (ON/OFF) Indicates status of MOP control TRUCK UNIT CNF6 : choix (ON/OFF) Indicates to the control if the system has been selected for truck operation HIGH SPEED OVERRIDE CNF7 : choix (ON/OFF) Indicates to the control if the low speed coolant check logic is enabled ELECTRIC FAN CNF8 : choix (ON/OFF) Indicates to the control if electric fans are being used OUT-OF-RANGE SHUT DOWN CNF9 : choix (ON/OFF) Indicates if main compartment out-of-range alarm shuts unit down after 45min. NOT ASSIGNED FOR TRAILER CNF10 : choix (ON/OFF) Not used FUNCTIONAL PARAMETERS (KEYPAD) LOCKOUT OPTION CNF11 : choix (ON/OFF) Allow or lockout certain any changes of the functional parameter from keypad HP-62 MOP OPTION CNF12 : choix (ON/OFF) Use either normal or HP-62 MOP parameters HEAT ONLY UNIT OPERATION OPTION CNF13 : choix (ON/OFF) Converts unit to a "Heat only" unit INVERTABLE MULTI TEMP CNF14 : choix (ON/OFF) Indicates to the control if reversible multi temp control is active ULTRA FRESH II OPTION (Trailer unit) CNF15 : choix (ON/OFF) Indicates to the control if the Ultra Fresh II temperature control is enable SHUNT DOWN WITH ALTERNATOR AUX ALARM CNF16 : choix (ON/OFF) Indicates if alternator AUX alarm shuts unit down in diesel mode ULTRA FREEZE 1 OPERATION CNF 17 : choix (ON/OFF) Indicates to the control if UFZ1 operation can run LOW REFRIGERANT TEST CNF 18 : choix (ON/OFF) Indicates to the control if low refrigerant test is enable NOT ASSIGNED FOR TRAILER CNF 19 : choix (ON/OFF) Not used UNITS SELECTION LOCK OPTION CNF 20 : choix (ON/OFF) Indicates to the control if the units functional parameter is locked FROZEN MODE PRIORITY LOGIC OPTION CNF 21 : choix (ON/OFF) Enables frozen priority logic NOT CURRENTLY ASSIGNED CNF 22 : choix (ON/OFF) Not used SET POINT LOCK CNF 23 : choix (ON/OFF) Indicates if the change of the Set Point is locked NOT ASSIGNED FOR TRAILER CNF 24 : choix (ON/OFF) Not used ON Set Point is locked Not used ON OFF OFF OFF OFF OFF OFF Set Point is not locked ON OFF OFF OFF OFF OFF OFF Active Not used ON OFF OFF ON OFF OFF OFF ON OFF Unit selection is locked Frozen priority not active ON OFF ON METRIC OFF ON METRIC ON METRIC OFF ON METRIC OFF ON METRIC Metric unit or english metric is not locked ON OFF Enable low refrigerrant test Not used ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Enable Ultra freeze 1 Disable low refrigerrant test ON OFF Alt aux alarm & unit shut down Disable Ultra freeze 1 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Logic enabled Alt aux alarm only ON OFF Reversible multi-temp active Logic disabled ON OFF OFF ON OFF OFF OFF ON OFF Heat only operation (Solara) Not active ON OFF OFF OFF OFF Active Normal cool / heat / defrost operation ON OFF OFF OFF OFF OFF OFF Functions locked MOP parameter HP 62 option ON OFF OFF OFF OFF OFF OFF Functions normal ON OFF OFF OFF OFF OFF OFF Out of range alarm and unit shut down Not used ON OFF OFF OFF OFF OFF OFF Electrical fan motors Out of range alarm only ON OFF OFF OFF OFF OFF OFF Logic enabled Belt driven fan ON OFF OFF OFF OFF OFF OFF Truck unit Logic disabled ON OFF OFF OFF OFF OFF OFF MOP enabled Trailer unit ON OFF OFF OFF OFF OFF OFF Override Enabled MOP disabled ON OFF OFF ON OFF OFF OFF ON OFF 32c (90F) Max. Set point Overide not enabled ON OFF OFF OFF OFF CDT used 30c (86F) Max. Set point ON OFF OFF OFF OFF OFF OFF TV Engine short glow cycle CDT not used TV OFF TV OFF TV OFF TV OFF TV OFF TV OFF

Description
DI Engine long glow cycle

Maxima 1300 Soft DI 3.31

Maxima 1300 MT 3.31

Maxima 1000 3.31

Maxima 1200 3.31

Maxima 1200 MT 3.31

CNF 25 to CNF 32 : choix (ON/OFF)

Not used

OFF

OFF

OFF

OFF

OFF

OFF

Micro parameters FN0 FN1 FN2 FN3 FN4 FN5 FN6 FN7 FN8 FN9 FN10 FN11 Affichage display Manuel glow override Alarm reset Defrost setting : 1,5;3;6;12h ON/OFF Air On = high/Off=Norm Off time choice : 10;20;30;45;90mn On time choice 4;7 A/B PROBE choice A=Rem/B=Sup F/C degree choix : F or C On=time start/ Off=temp start MOP choice : STD=0/-=-5/+=+4 2SET Set point adjustment 2CP 3SET Set point adjustment 3CP Start Op choice : on=Auto/off=Man T range choix A=2, B=3, C=4 Dreg C T Range choix : CODES OU ENGLISH choice NORM / ADD CLR/RST 3h OFF=Norm air 10mn 4 mn A=Rem probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow RST 3h OFF=Norm air 10mn 4 mn B=Sup probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow RST 3h 3h 3h OFF=Norm air 10mn 4 mn B=Sup probe deg C OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow RST

OFF=Norm air OFF=Norm air 10mn 4 mn A=Rem probe deg C 10mn 4 mn A=Rem probe deg C

OFF=Temp strt OFF=Temp strt STD=0 Sans Sans On = Auto OP C English Norm Glow RST STD=0 Sans Sans On = Auto OP C English Norm Glow RST

Update 22/02/2008

MICRO CONFIGURATIONS AND FUNCTIONS

TM1000 / TM800
MICRO configuration CNF1: choix(DI/TV) CNF2 : choix (ON/OFF) CNF3 : choix (ON/OFF) CNF4 : choix (ON/OFF) CNF5 : choix (ON/OFF) CNF6 : choix (ON/OFF) CNF7 : choix (ON/OFF) CNF8 : choix (ON/OFF) CNF9 : choix (ON/OFF) CNF10 : choix (ON/OFF) CNF11 : choix (ON/OFF) CNF12 : choix (ON/OFF) CNF13 : choix (ON/OFF) CNF14 : choix (ON/OFF) CNF15 : choix (ON/OFF) CNF16 : choix (ON/OFF) CNF 17 : choix (ON/OFF) CNF 18 : choix (ON/OFF) CNF 19 : choix (ON/OFF) CNF 20 : choix (ON/OFF) CNF 21 : choix (ON/OFF) CNF 22 : choix (ON/OFF) CNF 23 : choix (ON/OFF) CNF 24 : choix (ON/OFF)

Description
GLOW TIME Indicates to the control which engine is in the system and which glow time should be DISCHARGE SENSOR Indicates to the control if the DISCHARGE sensor is installed HIGH SETPOINT Indicates maximum Set Point allowed HEAT LOCKOUT OVERRIDE (Maxima MT Only) Indicates to the control if the heat lockout is overridden MOP Indicates status of MOP control TRUCK UNIT Indicates to the control if the system has been selected for truck operation HIGH SPEED OVERRIDE Indicates to the control if the low speed coolant check logic is enabled ELECTRIC FAN Indicates to the control if electric fans are being used OUT-OF-RANGE SHUT DOWN Indicates if main compartment out-of-range alarm shuts unit down after 45min. NOT ASSIGNED FOR TRAILER FUNCTIONAL PARAMETERS (KEYPAD) LOCKOUT OPTION Allow or lockout certain any changes of the functional parameter from keypad HP-62 MOP OPTION Use either normal or HP-62 MOP parameters HEAT ONLY UNIT OPERATION OPTION Converts unit to a "Heat only" unit INVERTABLE MULTI TEMP Indicates to the control if reversible multi temp control is active ULTRA FRESH II OPTION (Trailer unit) Indicates to the control if the Ultra Fresh II temperature control is enable SHUNT DOWN WITH ALTERNATOR AUX ALARM Indicates if alternator AUX alarm shuts unit down in diesel mode ULTRA FREEZE 1 OPERATION Indicates to the control if UFZ1 operation can run LOW REFRIGERANT TEST Indicates to the control if low refrigerant test is enable NOT ASSIGNED FOR TRAILER UNITS SELECTION LOCK OPTION Indicates to the control if the units functional parameter is locked FROZEN MODE PRIORITY LOGIC OPTION Enables frozen priority logic NOT CURRENTLY ASSIGNED SET POINT LOCK Indicates if the change of the Set Point is locked NOT ASSIGNED FOR TRAILER DI Engine long glow cycle TV Engine short glow cycle CDT not used CDT used 30c (86F) Max. Set point 32c (90F) Max. Set point Heat lockout on -12c (10F) Heat lockout off MOP disabled MOP enabled Trailer unit Truck unit Logic disabled Logic enabled Belt driven fan Electrical fan motors Out of range alarm only Out of range alarm and unit shut down Not used Not used Functions normal Functions locked MOP parameter HP 62 option Active Normal cool / heat / defrost operation Heat only operation (Solara) Not active Reversible multi-temp active Logic disabled Logic enabled Alt aux alarm only Alt aux alarm & unit shut down Disable Ultra freeze 1 Enable Ultra freeze 1 Disable low refrigerrant test Enable low refrigerrant test Not used Not used Metric unit or english metric is not locked Unit selection is locked Frozen priority not active Active Not used Not used Set Point is not locked Set Point is locked Not used Not used Not used Micro parameters FN0 FN1 FN2 FN3 FN4 FN5 FN6 FN7 FN8 FN9 FN10 FN11 Affichage display Manuel glow override Alarm reset Defrost setting : 1,5;3;6;12h ON/OFF Air On = high/Off=Norm Off time choice : 10;20;30;45;90mn On time choice 4;7 A/B PROBE choice A=Rem/B=Sup F/C degree choix : F or C On=time start/ Off=temp start MOP choice : STD=0/-=-5/+=+4 2SET Set point adjustment 2CP 3SET Set point adjustment 3CP Start Op choice : on=Auto/off=Man T range choix A=2, B=3, C=4 Dreg C T Range choix : CODES OU ENGLISH choice NORM / ADD CLR/RST

Soft DI TV OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF

TM 1000 / TM800 3.31 TV ON OFF OFF

ON OFF OFF OFF

ON OFF OFF

ON OFF

ON ON ON ON ON OFF OFF OFF OFF OFF OFF

CNF 25 to CNF 32 : choix (ON/OFF)

OFF

6H Norm 20 4 Rem C time start MOP + 32F or Oc 32F or Oc Auto Op T range A English Norm CLR

Update 22/02/2008

MICRO CONFIGURATIONS AND FUNCTIONS

TR1000
MICRO configuration CNF1: choix(DI/TV) CNF2 : choix (ON/OFF) CNF3 : choix (ON/OFF) CNF4 : choix (ON/OFF) CNF5 : choix (ON/OFF) CNF6 : choix (ON/OFF) CNF7 : choix (ON/OFF) CNF8 : choix (ON/OFF) CNF9 : choix (ON/OFF) CNF10 : choix (ON/OFF) CNF11 : choix (ON/OFF) CNF12 : choix (ON/OFF) CNF13 : choix (ON/OFF) CNF14 : choix (ON/OFF) CNF15 : choix (ON/OFF) CNF16 : choix (ON/OFF) DI TV OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON Description Soft DI Engine long glow cycle TV Engine short glow cycle CDT not used CDT used 30c (86F) Max. Set point 32c (90F) Max. Set point Heat lockout on -12c (10F) Heat lockout off (truck units) MOP disabled MOP enabled Trailer unit Truck unit Low speed start High speed start Belt driven fan Electrical fan motors Out of range alarm not shut down Out of range alarm and unit shut down No auto restart Auto restart active Functions normal Functions locked MOP parameter HP 62 option Active Cool / heat / defrost Heat only (Solara) Not active Not active Alt aux alarm only Alt aux alarm & unit shut down TR1000 4,05 TV ON OFF OFF

ON OFF OFF OFF OFF (option) OFF OFF (option) OFF OFF OFF OFF

ON

FN0 FN1 FN2 FN3 FN4 FN5 FN6 FN7 FN8 FN9 FN10 FN11 Affichage display Manuel glow override Alarm reset

Defrost setting : 1,5;3;6;12h ON/OFF Air On = high/Off=Norm Off time choice : 10;20;30;45;90mn On time choice 4;7 A/B PROBE choice A=Rem/B=Sup F/C degree choix : F or C On=time start/ Off=temp start MOP choice : STD=0/-=-5/+=+4 2SET Set point adjustment 2CP 3SET Set point adjustment 3CP Start Op choice : on=Auto/off=Man T range choix A=2, B=3, C=4 Dreg C T Range choix : CODES OU ENGLISH choice NORM / ADD CLR/RST

6H Norm 20 7 Rem C temp start MOP STD 32F or Oc 32F or Oc Man T range B English Norm CLR

Update 22/02/2008

MICRO CONFIGURATIONS AND FUNCTIONS

ULTRA
MICRO configuration

Description
Soft GLOW TIME Indicates to the control which engine is in the system and which glow time should be DISCHARGE SENSOR Indicates to the control if the DISCHARGE sensor is installed HIGH SETPOINT Indicates maximum Set Point allowed HEAT LOCKOUT OVERRIDE (Maxima MT Only) Indicates to the control if the heat lockout is overridden MOP Indicates status of MOP control TRUCK UNIT Indicates to the control if the system has been selected for truck operation HIGH SPEED OVERRIDE Indicates to the control if the low speed coolant check logic is enabled ELECTRIC FAN Indicates to the control if electric fans are being used OUT-OF-RANGE SHUT DOWN Indicates if main compartment out-of-range alarm shuts unit down after 45min. NOT ASSIGNED FOR TRAILER FUNCTIONAL PARAMETERS (KEYPAD) LOCKOUT OPTION Allow or lockout certain any changes of the functional parameter from keypad HP-62 MOP OPTION Use either normal or HP-62 MOP parameters HEAT ONLY UNIT OPERATION OPTION Converts unit to a "Heat only" unit INVERTABLE MULTI TEMP Indicates to the control if reversible multi temp control is active ULTRA FRESH II OPTION (Trailer unit) Indicates to the control if the Ultra Fresh II temperature control is enable SHUNT DOWN WITH ALTERNATOR AUX ALARM Indicates if alternator AUX alarm shuts unit down in diesel mode ULTRA FREEZE 1 OPERATION Indicates to the control if UFZ1 operation can run LOW REFRIGERANT TEST Indicates to the control if low refrigerant test is enable XT units UNITS SELECTION LOCK OPTION Indicates to the control if the units functional parameter is locked FROZEN MODE PRIORITY LOGIC OPTION Enables frozen priority logic NOT CURRENTLY ASSIGNED SET POINT LOCK Indicates if the change of the Set Point is locked NOT ASSIGNED FOR TRAILER DI Engine long glow cycle TV Engine short glow cycle CDT not used CDT used 30c (86F) Max. Set point 32c (90F) Max. Set point Heat lockout on -12c (10F) Heat lockout off MOP disabled MOP enabled Trailer unit Truck unit Logic disabled Logic enabled Belt driven fan Electrical fan motors Out of range alarm only Out of range alarm and unit shut down Not used Not used Functions normal Functions locked MOP parameter HP 62 option Active Normal cool / heat / defrost operation Heat only operation (Solara) Not active Reversible multi-temp active Logic disabled Logic enabled Alt aux alarm only Alt aux alarm & unit shut down Disable Ultra freeze 1 Enable Ultra freeze 1 Disable low refrigerrant test Enable low refrigerrant test Non-XT units XT units only Metric unit or english metric is not locked Unit selection is locked Frozen priority not active Active Not used Not used Set Point is not locked Set Point is locked Not used Not used Not used Micro parameters FN0 FN1 FN2 FN3 FN4 FN5 FN6 FN7 FN8 FN9 FN10 FN11 Affichage display Manuel glow override Alarm reset Defrost setting : 1,5;3;6;12h ON/OFF Air On = high/Off=Norm Off time choice : 10;20;30;45;90mn On time choice 4;7 A/B PROBE choice A=Rem/B=Sup F/C degree choix : F or C On=time start/ Off=temp start MOP choice : STD=0/-=-5/+=+4 2SET Set point adjustment 2CP 3SET Set point adjustment 3CP Start Op choice : on=Auto/off=Man T range choix A=2, B=3, C=4 Dreg C T Range choix : CODES OU ENGLISH choice NORM / ADD CLR/RST DI TV OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF

Ultra/Optima Extra 3.31 TV ON OFF (Option) OFF

Extra XT 3.31 TV ON OFF (Option) OFF

CNF1: choix(DI/TV) CNF2 : choix (ON/OFF) CNF3 : choix (ON/OFF) CNF4 : choix (ON/OFF) CNF5 : choix (ON/OFF) CNF6 : choix (ON/OFF) CNF7 : choix (ON/OFF) CNF8 : choix (ON/OFF) CNF9 : choix (ON/OFF) CNF10 : choix (ON/OFF) CNF11 : choix (ON/OFF) CNF12 : choix (ON/OFF) CNF13 : choix (ON/OFF) CNF14 : choix (ON/OFF) CNF15 : choix (ON/OFF) CNF16 : choix (ON/OFF) CNF 17 : choix (ON/OFF) CNF 18 : choix (ON/OFF) CNF 19 : choix (ON/OFF) CNF 20 : choix (ON/OFF) CNF 21 : choix (ON/OFF) CNF 22 : choix (ON/OFF) CNF 23 : choix (ON/OFF) CNF 24 : choix (ON/OFF)

ON OFF OFF OFF OFF (Option) OFF OFF (Option)

ON OFF OFF OFF OFF (Option) OFF OFF (Option)

ON OFF OFF

ON OFF OFF

ON (Option) OFF (Option)

ON (Option) OFF (Option)

ON (Option) ON (Option) OFF OFF (Option) NA NA OFF NA

ON (Option) ON (Option) ON OFF (Option) NA NA OFF NA

CNF 25 to CNF 32 : choix (ON/OFF)

OFF

OFF

6H OFF=Norm air 10 mn 4 mn A=rem Probe Deg F OFF=temp strt STD=0 sans sans ON=Auto OP C English Norm Glow CLR

6H OFF=Norm air 10 mn 4 mn A=rem Probe Deg F OFF=temp strt STD=0 sans sans ON=Auto OP C English Norm Glow CLR

Update 22/02/2008

MICRO CONFIGURATIONS AND FUNCTIONS

XARIOS
XARIOS ROAD / STAND-BY
MICRO CONFIGURATION

Xarios 150/150- Xarios 150/150 04/200/20004/200/200with Hot gas 04/300/300-05 04/300/300-05 heating option road / stand-by road / standby 24v 12v
AUT HIGH Ut C PS 12 Fan1 SPD3 2ET hrof hsof drof doff euof spof 0C - 29 C + 20 C dif1 Foff AUT HIGH Ut C PS 24 Fan1 SPD3 2ET hrof hsof drof doff euof spof 0C - 29 C + 20 C dif1 Foff

Xarios Xarios 350/350350/350with Hot gas 05/400/500-04 05/400/500-04 heating option road / stand- road / standby 24v by 12v
AUT HIGH Ut C PS 12 Fan2 SPD3 2ET hrof hsof drof doff euof spof 0C - 29 C + 20 C dif1 Foff AUT HIGH Ut C PS 24 Fan2 SPD3 2ET hrof hsof drof doff euof spof 0C - 29 C + 20 C dif1 Foff

Xarios Xarios 500/600/ road 500/600/ road / stand-by 12v / stand-by 24v

DEFROST BRIGHTNESS UNIT (Ut) BATTERY VOLTAGE (PS) NUMBER OF FAN (FAn) FAN SPEED (SPd) NUMBER OF STAGES (ET) OPTIONNAL HEATING ROAD (hr) OPTIONNAL HEATING STANDBY (hs) OPTIONNAL DRAIN RESISTOR (dr) OPTIONNAL DOOR SWITCH (d) * HYBRID UNIT ONLY (eu) * OPTIONNAL SET POINT LOCK SET POINT

AUT HIGH Ut C PS 12 Fan3 SPD3 3ET hrof hsof drof doff euof spof 0C - 29 C + 20 C dif1 Foff

AUT HIGH Ut C PS 24 Fan3 SPD3 3ET hrof hsof drof doff euof spof 0C - 29 C + 20 C dif1 Foff

configuration

3ET

3ET

Parameters

LOW SET POINT HIGH SET POINT TEMPERATURE DIFFERENCIAL (dif) EVAPORATOR FAN CONTINUOUS RUN (F)

* starting with soft 1,91 XARIOS ROAD ONLY


xarios 150-04 / 200-04 / 300-05 / 350-05 12V 10mn 1h HIGH Ut C _ _ _ 3 _ _ _ _ 0C 0 30C dif2 off xarios 150-04 / 20004 / 300-05 / 350-05 24V 10mn 1h HIGH Ut C _ _ _ 3 _ _ _ _ 0C 0 30C dif2 off

MICRO CONFIGURATION

DEFROST BRIGHTNESS UNIT (Ut) BATTERY VOLTAGE (PS) NUMBER OF FAN (FAn) FAN SPEED (SPd) NUMBER OF STAGES (ET) OPTIONNAL HEATING ROAD (hr) OPTIONNAL HEATING STANDBY (hs) DRAIN RESISTOR (dr) DOOR SWITCH (d) SET POINT

parameters

configurations

LOW SET POINT HIGH SET POINT TEMPERATURE DIFFERENCIAL (dif) EVAPORATOR FAN CONTINUOUS RUN (F)

XARIOS MT
ROAD / ROAD STANDBY
MICRO CONFIGURATION DEFROST operating mode selection DEFROST interval BRIGHTNESS UNIT (Ut) BATTERY VOLTAGE (PS) xarios 350/350-05 MT Road / road stand-by 12v Simu 3H HIGH Ut C PS 12 xarios 350/350-05 MT Road / road stand-by 24v Simu 3H HIGH Ut C PS 24 Xarios 500 MT Road / Road stand-by 12v Simu 3H HIGH Ut C PS 12 Xarios 600 MT Xarios 600 MT Xarios 500 MT Road Road / Road stand- Road / Road stand/ Road stand-by 24v by 12V by 24V Simu Simu Simu 3H 3H 3H HIGH HIGH HIGH Ut C PS 24 Ut C PS 12 Ut C PS 24

configurations

** to be selected
NUMBER OF FAN (FAn)

** to be
selected regarding evaporators
SPD3 / hrof hsof drof doff aloff 0C/-20C Auto - 29 C + 20 C dif2 Foff

** to be
selected regarding evaporators
SPD3 / hrof hsof drof doff aloff 0C/-20C Auto - 29 C + 20 C dif2 Foff

** to be
selected regarding evaporators
SPD3 / hrof hsof drof doff aloff 0C/-20C Auto - 29 C + 20 C dif2 Foff

** to be
selected regarding evaporators
SPD3 / hrof hsof drof doff aloff 0C/-20C Auto - 29 C + 20 C dif2 Foff

** to be
selected regarding evaporators
SPD3 / hrof hsof drof doff aloff 0C/-20C Auto - 29 C + 20 C dif2 Foff

regarding evaporators
SPD3 / hrof hsof drof doff aloff 0C/-20C Auto - 29 C + 20 C dif2 Foff

FAN SPEED (SPd) NUMBER OF STAGES (ET) OPTIONNAL HEATING ROAD (hr) OPTIONNAL HEATING STANDBY (hs) DRAIN RESISTOR (dr) DOOR SWITCH (d) ALARM OUT OF RANGE (al) SET POINT COOLING operating mode selection

parameters

LOW SET POINT HIGH SET POINT TEMPERATURE DIFFERENCIAL (dif) EVAPORATOR FAN CONTINUOUS RUN (F)

** MXS 600 fan1 ** MXS 850 fan1 ** MXV 850 fan1 ** MXL 1100 fan2

Update 22/02/2008

NEOS 100 route

NEOS 100 Route/secteur AUT 0C Ut C PS 12 3ET doff - 29 C dif2 Foff

MICRO CONFIGURATION
DEFROST SET POINT UNITY (Ut) BATTERY VOLTAGE (PS) NUMBER OF STAGES (ET) DOOR SWITCH (d) LOW SET POINT TEMPERATURE DIFFERENCIAL (dif) EVAPORATOR FAN CONTINUOUS RUN (F) AUT 0C Ut C PS 12 3ET doff - 29 C dif2 Foff

Update 22/02/2008

MICRO CONFIGURATIONS AND FUNCTIONS

VIENTO
VIENTO ROAD ONLY Soft version
MICRO CONFIGURATION

VIENTO 350 CH VIENTO 350 LA VIENTO 350 R134A / HA R134A LA / HA R404A 4,0
NATURAL Ut C 2ET* 0C 0C + 30 C dif2 Foff

VIENTO 300 CH R134A 4,0


NATURAL Ut C 2ET* 0C 0C + 30 C dif2 Foff

VIENTO VIENTO 300 LA / 300 LA / HA R134A HA R404A 4,0


1H - 15' Ut C 3ET* 0C 0C + 30 C dif2 Foff

SOFTWARE DEFROST BRIGHTNESS UNIT (Ut) BATTERY VOLTAGE (PS) NUMBER OF FAN (FAn) FAN SPEED (SPd) NUMBER OF STAGES (ET) OPTIONNAL HEATING ROAD (hr) OPTIONNAL HEATING STANDBY (hs) OPTIONNAL DRAIN RESISTOR (dr) OPTIONNAL DOOR SWITCH (d) SET POINT

4,0
1H - 15' Ut C 3ET* 0C 0C + 30 C dif2 Foff

4,0
1H - 15' Ut C 3ET* 0C 0C + 30 C dif2 Foff

4,0
1H - 15' Ut C 3ET* 0C 0C + 30 C dif2 Foff

VIENTO VIENTO VIENTO 200 LA / 200 LA / 200 CH HA HA R134A R134A R404A 4,0 4,0 4,0
NATURAL Ut C 2ET* 0C 0C + 30 C dif2 Foff 1H - 15' Ut C 3ET* 0C 0C + 30 C dif2 Foff 1H - 15' Ut C 3ET* 0C 0C + 30 C dif2 Foff

Parameters

configuration

LOW SET POINT HIGH SET POINT TEMPERATURE DIFFERENCIAL (dif) EVAPORATOR FAN CONTINUOUS RUN (F)

preset in the micro software

Update 22/02/2008

VECTOR UNIT MODEL NO: NDP33LN6FBZ


SETTINGS CONFIGURATION PARAMETER Coolset
SERIAL NUMBER NO TRAILER ID GLOW TIME OUT OF RANGE SHUTDOWN PARAMETERS LOCKOUT RPM ALARM SHUTDOWN LOW PRESSURE SHUTDOWN L P SHUTDOWN DELAY HIGH SUC PRESS SHUTDOWN REFRIGERATION SYS SHUTDOWN COMPRESSOR ALARM SHUTDOWN SUCTION PRESSURE CURRENT FOR S/S SHUTDOWN VOLTAGE FOR S/S RESTART ALTERNATOR CHECK SHUTDOWN ENGINE OIL LEVEL SWITCH ENGINE OIL LEVEL SHUTDOWN LOW COOLANT LEVEL FUEL TANK FUEL TANK SIZE DIESEL MAX GENERATOR CURR STANDBY MAX GEN CURR INITIAL GENERATOR CURRENT DIESEL OFFSET FOR CURRENT STANDBY START UP DELAY DISPLAY TOTAL ENGINE HOURS DISPLAY TOTAL STANDBY HOURS DISPLAY TOTAL SWITCH ON HOURS DIESEL RESET VALUE STANDBY RESET VALUE SWITCH ON RESET VALUE PM1 RESET INTERVAL PM2 RESET INTERVAL PM3 RESET INTERVAL PM4 RESET INTERVAL PM5 RESET INTERVAL PRODUCT SHIELD ECONO PRODUCT SHIELD ECONO MIN TEMP PRODUCT SHIELD ECONO MAX TEMP PRODUCT SHIELD ECONO DELTA T PRODUCT SHIELD HIGH AIR PRODUCT SHIELD HIGH AIR MIN TEMP PRODUCT SHIELD HIGH AIR MAX TEMP PRODUCT SHIELD HIGH AIR DELTA T PRODUCT SHIELD WINTER RANGE 1 LOCK RANGE 1 MINIMUN TEMP RANGE 1 MAXIMUM TEMP RANGE 2 LOCK RANGE 2 LOCK MINIMUN TEMP RANGE 2 LOCK MAXIMUM TEMP MINIMUM SETPOINT MAXIMUM SETPOINT NO POWER STOP/START PARAMETERS REMOTE TEMP SENSOR 1 REMOTE TEMP SENSOR 2 REMOTE TEMP SENSOR 3 DOOR SWITCH TYPE DOOR SWITCH ALARM REMS 1 REMS 1 REMS 2 REMS 2 LIGHT BAR 8 HR ADDITIONAL DATA DECIMAL DISPLAYED CONDENSER PRESSURE CONTROL HIGH SPEED DELAY SUPPLY AIR LIMIT S/S SUPPLY AIR LIMIT CONT HIGH SPEED PULLDOWN SATELLITE COMM UNIT OPERATION ENABLE INTELLISET AT = KEY Soft 04.05.00
XXXX XXXX SHORT NO NO YES YES 255 SECS NO YES NO 2.1 BAR 5A 12,2V NO NO NO NO NO DEVICE OFF 26A 22A 17A 4A OFF YES YES YES 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 32.0 DEG C 32.0 DEG C OFF 32.0 DEG C 32.0 DEG C -30 DEG C +32 DEG C INSTALLED & SHUTDOWN SEPARATE OFF OFF OFF NOT INSTALLED ALARM ONLY NOT INSTALLED ALARM ONLY NOT INSTALLED ALARM ONLY 8 LIGHT NO DISPLAYED NO 1.0 MIN -6.0 DEG C -5.0 DEG C YES OTHER STANDARD NO XXXX XXXX SHORT NO NO YES YES 255 SECS NO YES NO 2.1 BAR 5A 12,2V NO NO NO NO NO DEVICE OFF 26A 22A 17A 4A OFF YES YES YES 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 32.0 DEG C 32.0 DEG C OFF 32.0 DEG C 32.0 DEG C -30 DEG C +32 DEG C INSTALLED & SHUTDOWN SEPARATE OFF OFF OFF NOT INSTALLED ALARM ONLY NOT INSTALLED ALARM ONLY NOT INSTALLED ALARM ONLY 8 LIGHT NO DISPLAYED NO 1.0 MIN -6.0 DEG C -5.0 DEG C NO OTHER STANDARD NO

SETTINGS FUNCTIONAL PARAMETER Ecofuel


DEFROST TIMER SET FOR PERISH MIN RUN TIME PERISH MIN OFF TIME PERISH OVERRIDE TEMP PERISH MAX OFF TIME FROZEN MIN RUN TIME FROZEN MIN OFF TIME FROZEN OVERRIDE TEMP FROZEN MAX OFF TIME FROZEN SHUTDOWN OFFSET PERISH SENSITIVE PRODUCT TEMP CONTROL DISPLAY IN (LOCKED) ECO MODE ENGINE HOURS STANDBY HOURS SWITCH ON HOURS PM 1 PM 2 PM 3 PM 4 PM 5 OUT OF RANGE ALARM SILENT MODE SLEEP MODE OVERRIDE DOOR SHUTDOWN OVERRIDE REMS1 SHUTDOWN OVERRIDE REMS2 SHUTDOWN NO POWER SWITCH TO DIESEL
6HRS 4 MIN 20 MIN 3 DEG C 0 MIN 4 MIN 30 MIN 4 DEG C 0 MIN 0 DEG C OFF RETURN AIR METRIC UNITS NO OFF OFF OFF OFF OFF OFF OFF OFF 4 DEG C NO NO NO NO NO NO

Coolset
6HRS 4 MIN 30 MIN 4 DEG C 0 MIN 4 MIN 45 MIN 5 DEG C 0 MIN 0 DEG C OFF RETURN AIR

Ecofuel

METRIC UNITS YES OFF OFF OFF OFF OFF OFF OFF OFF 4 DEG C NO NO NO NO NO NO

Update 22/02/2008

VECTOR MT UNIT MODEL NO:NDP33LN6FBR2/3


CONFIGURATION PARAMETER
SERIAL NUMBER NO TRAILER ID GLOW TIME OUT OF RANGE SHUTDOWN PARAMETERS LOCKOUT RPM ALARM SHUTDOWN LOW PRESSURE SHUTDOWN L P SHUTDOWN DELAY HIGH SUC PRESS SHUTDOWN REFRIGERATION SYS SHUTDOWN COMPRESSOR ALARM SHUTDOWN SUCTION PRESSURE CURRENT FOR S/S SHUTDOWN VOLTAGE FOR S/S RESTART ALTERNATOR CHECK SHUTDOWN ENGINE OIL LEVEL SWITCH ENGINE OIL LEVEL SHUTDOWN LOW COOLANT LEVEL FUEL TANK FUEL TANK SIZE DIESEL MAX GENERATOR CURR STANDBY MAX GEN CURR INITIAL GENERATOR CURRENT DIESEL OFFSET FOR CURRENT STANDBY START UP DELAY DISPLAY TOTAL ENGINE HOURS DISPLAY TOTAL STANDBY HOURS DISPLAY TOTAL SWITCH ON HOURS DIESEL RESET VALUE STANDBY RESET VALUE SWITCH ON RESET VALUE PM1 RESET INTERVAL PM2 RESET INTERVAL PM3 RESET INTERVAL PM4 RESET INTERVAL PM5 RESET INTERVAL PRODUCT SHIELD ECONO PRODUCT SHIELD ECONO MIN TEMP PRODUCT SHIELD ECONO MAX TEMP PRODUCT SHIELD ECONO DELTA T PRODUCT SHIELD HIGH AIR PRODUCT SHIELD HIGH AIR MIN TEMP PRODUCT SHIELD HIGH AIR MAX TEMP PRODUCT SHIELD HIGH AIR DELTA T PRODUCT SHIELD WINTER RANGE 1 LOCK RANGE 1 MINIMUN TEMP RANGE 1 MAXIMUM TEMP RANGE 2 LOCK RANGE 2 LOCK MINIMUN TEMP RANGE 2 LOCK MAXIMUM TEMP MINIMUM SETPOINT MAXIMUM SETPOINT C2 SETPOINT MINIMUM C2 SETPOINT MAXIMUM C3 SETPOINT MINIMUM (BR3 only) C3 SETPOINT MAXIMUM (BR3 only) NO POWER STOP/START PARAMETERS REMOTE TEMP SENSOR 1 (BR2 only) REMOTE TEMP SENSOR 2 (BR2 only) DOOR SWITCH TYPE (BR2 only) DOOR SWITCH ALARM (BR2 only) LIGHT BAR 8 HR ADDITIONAL DATA PERISHABLE FAN MODE FROZEN PRIORITY COOLING CONDENSER PRESSURE CONTROL HIGH SPEED DELAY SUPPLY AIR LIMIT S/S SUPPLY AIR LIMIT CONT SAT 2 C2 SUPPLY AIR LIMIT FOR S/S C2 SUPPLY AIR LIMIT FOR CONT HIGH SPEED PULLDOWN SATELLITE COMM UNIT OPERATION ENABLE INTELLISET AT = KEY Soft 04.05.00
XXXX XXXX SHORT NO NO YES YES 255 SECS NO YES NO 2.1 BAR 7A 12,2V NO NO NO NO NO DEVICE OFF 26A 22A 17A 4A OFF YES YES YES 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 32.0 DEG C 32.0 DEG C OFF 32.0 DEG C 32.0 DEG C -30 DEG C +32 DEG C -30 DEG C +32 DEG C -30 DEG C +32 DEG C INSTALLED & SHUTDOWN SEPARATE OFF OFF NOT INSTALLED ALARM ONLY 2 LIGHT NO OFF OFF NO 1.0 MIN -6.0 DEG C -5.0 DEG C NOT INSTALLED -3.0 DEG C -1;0 DEG C YES OTHER STANDARD NO

SETTINGS Coolset
XXXX XXXX SHORT NO NO YES YES 255 SECS NO YES NO 2.1 BAR 7A 12,2V NO NO NO NO NO DEVICE OFF 26A 22A 17A 4A OFF YES YES YES 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR 0 HOUR OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 32.0 DEG C 32.0 DEG C OFF 32.0 DEG C 32.0 DEG C -30 DEG C +32 DEG C -30 DEG C +32 DEG C -30 DEG C +32 DEG C INSTALLED & SHUTDOWN SEPARATE OFF OFF NOT INSTALLED ALARM ONLY 2 LIGHT NO OFF OFF NO 1.0 MIN -6.0 DEG C -5.0 DEG C NOT INSTALLED -3.0 DEG C -1;0 DEG C NO OTHER STANDARD NO

Ecofuel

FUNCTIONAL PARAMETER
DEFROST TIMER SET FOR PERISH MIN RUN TIME PERISH MIN OFF TIME PERISH OVERRIDE TEMP PERISH MAX OFF TIME FROZEN MIN RUN TIME FROZEN MIN OFF TIME FROZEN OVERRIDE TEMP FROZEN MAX OFF TIME FROZEN SHUTDOWN OFFSET PERISH SENSITIVE PRODUCT TEMP CONTROL DISPLAY IN (LOCKED) ECO MODE ENGINE HOURS STANDBY HOURS SWITCH ON HOURS PM 1 PM 2 PM 3 PM 4 PM 5 OUT OF RANGE ALARM C2 OUT OF RANGE ALARM C3 OUT OF RANGE ALARM (BR3 only) SILENT MODE SLEEP MODE
6HRS 4 MIN 20 MIN 3 DEG C 0 MIN 4 MIN 30 MIN 4 DEG C 0 MIN 0 DEG C OFF RETURN AIR

SETTINGS Coolset
6HRS 4 MIN 30 MIN 4 DEG C 0 MIN 4 MIN 45 MIN 5 DEG C 0 MIN 0 DEG C OFF RETURN AIR METRIC UNITS YES OFF OFF OFF OFF OFF OFF OFF OFF 4 DEG C 4 DEG C 4 DEG C NO NO NO NO

Ecofuel

METRIC UNITS NO OFF OFF OFF OFF OFF OFF OFF OFF 4 DEG C 4 DEG C 4 DEG C NO NO

OVERRIDE DOOR SHUTDOWN (BR2 only) NO NO POWER SWITCH TO DIESEL


NO