International Catalogue 2011

Delixi Electric: Who are we

A global company at your service


Delixi was founded in 1984 in Zhejiang province with sales over 1.5BM,employing more than 15000 people. Delixi created an international Joint Venture in November 2007,named Delixi Electric LTD,in order to serve you worldwide,with core LV products having the right quality at the right price. Our products are designed for Residential/Building/Energy/infrastructure and Industrial markets.Delixi Electric employs 5200 people world wide.

A reliable company serving you with reliable product


Dedicated R&D center International quality control of suppliers International quality control of plants

Fully automatized distribution center Network of recognized 600 distributors world wide

International quality control of plants

Reliable Quality

For more details, please contact your local Delixi Electric Company

Contents

Final Distribution

3-18
Miniature Circuit Breakers&Switch Disconnectors

19-32
Residual Current Devices

33-36
Accessories for MCB&RCBO

37-40
Control Devices

41-42
Surge Protective Devices

43-47
Distribution Box

Low-voltage Distribution

48-63
Molded Case Circuit Breaker

64-82
Air Circuit Breaker

Motor Control & Protection

86-127
Contactor&Thermal Overload Relay

128-134
Definite-purpose Contactors Relays

135-146

Power Energy Management

148-150
Current Transformer Meter

151-163

164-167
Digital Time Switch

168-174
Voltage Stabilizer

Industrial Control Components

175-202
Control Signal Fuse

203-208

209
Cable Connector

210-215
Industrial Plug& Socket

216-220
Copper Terminal Block Series Din-rail

221

Contents
Final Distribution

Miniature Circuit Breaker & Switch Disconnectors 3-18


CDB6 CDB6s CDB2 CDB3
Final Distribution

18mm Miniature Circuit Breaker 18mm Miniature Circuit Breaker 27mm Miniature Circuit Breaker Phase-neutral Circuit Breaker Switch Disconnector

4 8 12 15 17

CDB5

Residual Current Devices


CDB6LE CDB6v CDB2LE CDB3LE CDL7 Residual Current Operated Circuit Breaker Residual Current Protection Module Residual Current Operated Circuit Breaker Residual Current Operated Circuit Breaker Electromagnetic Type Residual Current Switch

19-32
20 23 26 29 31

Accessories for MCB&RCBO


SD,OF,MX+OF Busbar

33-36
33 36

Control Devices
CDCH8 CDRT8 Modular Contactor Time Relay

37-40 1~5
37 39

Surge Protective Devices


CDY1 Surge Protective Devices

41-42
41

1~5

Distribution Box
CDPZ50 Series JXF Lighting Distribution Box Power Distribution Box

43-47
43 45

Miniature Circuit Breaker & Switch Disconnectors Product Overview

18mm MCB

27mm MCB

Final Distribution

CDB6

CDB6s S

CDB2 In: 63-125A Breaking Capacity: 10kA

12

In: 1-63A Breaking Capacity: 3/4.5 kA

In: 1-63A Breaking Capacity: 4.5/6 kA A

18mm 1P+N MCB

Switch Disconnectors

CDB3

15

CDB5 In: 20-100A

17

In: 6-32A Breaking Capacity: 3kA

Accessories page**

33

MX+OF

SD

OF

CDB6 18mm Miniature Circuit Breaker


Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000 /4500A

RoHS

Function

CDB6 miniature circuit breaker combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Final Distribution

Order Information
Type 1P Breaking Capacity (kA) 3 Rating Width (A) 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 Reference B curve CDB6a1B1 CDB6a1B3 CDB6a1B6 CDB6a1B10 CDB6a1B16 CDB6a1B20 CDB6a1B25 CDB6a1B32 CDB6a1B40 CDB6a1B50 CDB6a1B63 CDB6L1B1 CDB6L1B3 CDB6L1B6 CDB6L1B10 CDB6L1B16 CDB6L1B20 CDB6L1B25 CDB6L1B32 CDB6L1B40 CDB6L1B50 CDB6L1B63 CDB6a2B1 CDB6a2B3 CDB6a2B6 CDB6a2B10 CDB6a2B16 CDB6a2B20 CDB6a2B25 CDB6a2B32 CDB6a2B40 CDB6a2B50 CDB6a2B63 C curve CDB6a1C1 CDB6a1C3 CDB6a1C6 CDB6a1C10 CDB6a1C16 CDB6a1C20 CDB6a1C25 CDB6a1C32 CDB6a1C40 CDB6a1C50 CDB6a1C63 CDB6L1C1 CDB6L1C3 CDB6L1C6 CDB6L1C10 CDB6L1C16 CDB6L1C20 CDB6L1C25 CDB6L1C32 CDB6L1C40 CDB6L1C50 CDB6L1C63 CDB6a2C1 CDB6a2C3 CDB6a2C6 CDB6a2C10 CDB6a2C16 CDB6a2C20 CDB6a2C25 CDB6a2C32 CDB6a2C40 CDB6a2C50 CDB6a2C63 D curve CDB6a1D1 CDB6a1D3 CDB6a1D6 CDB6a1D10 CDB6a1D16 CDB6a1D20 CDB6a1D25 CDB6a1D32 CDB6a1D40 CDB6a1D50 CDB6a1D63 CDB6L1D1 CDB6L1D3 CDB6L1D6 CDB6L1D10 CDB6L1D16 CDB6L1D20 CDB6L1D25 CDB6L1D32 CDB6L1D40 CDB6L1D50 CDB6L1D63 CDB6a2D1 CDB6a2D3 CDB6a2D6 CDB6a2D10 CDB6a2D16 CDB6a2D20 CDB6a2D25 CDB6a2D32 CDB6a2D40 CDB6a2D50 CDB6a2D63

4.5

2P

Note: Width refers to multiple of 9 mm.

CDB6 18mm Miniature Circuit Breaker


Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000 /4500A Order Information
Breaking Capacity (kA) 4.5 Rating Width (A) 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 Reference B curve CDB6L2B1 CDB6L2B3 CDB6L2B6 CDB6L2B10 CDB6L2B16 CDB6L2B20 CDB6L2B25 CDB6L2B32 CDB6L2B40 CDB6L2B50 CDB6L2B63 CDB6a3B1 CDB6a3B3 CDB6a3B6 CDB6a3B10 CDB6a3B16 CDB6a3B20 CDB6a3B25 CDB6a3B32 CDB6a3B40 CDB6a3B50 CDB6a3B63 CDB6L3B1 CDB6L3B3 CDB6L3B6 CDB6L3B10 CDB6L3B16 CDB6L3B20 CDB6L3B25 CDB6L3B32 CDB6L3B40 CDB6L3B50 CDB6L3B63 CDB6a4B1 CDB6a4B3 CDB6a4B6 CDB6a4B10 CDB6a4B16 CDB6a4B20 CDB6a4B25 CDB6a4B32 CDB6a4B40 CDB6a4B50 CDB6a4B63 C curve CDB6L2C1 CDB6L2C3 CDB6L2C6 CDB6L2C10 CDB6L2C16 CDB6L2C20 CDB6L2C25 CDB6L2C32 CDB6L2C40 CDB6L2C50 CDB6L2C63 CDB6a3C1 CDB6a3C3 CDB6a3C6 CDB6a3C10 CDB6a3C16 CDB6a3C20 CDB6a3C25 CDB6a3C32 CDB6a3C40 CDB6a3C50 CDB6a3C63 CDB6L3C1 CDB6L3C3 CDB6L3C6 CDB6L3C10 CDB6L3C16 CDB6L3C20 CDB6L3C25 CDB6L3C32 CDB6L3C40 CDB6L3C50 CDB6L3C63 CDB6a4C1 CDB6a4C3 CDB6a4C6 CDB6a4C10 CDB6a4C16 CDB6a4C20 CDB6a4C25 CDB6a4C32 CDB6a4C40 CDB6a4C50 CDB6a4C63 D curve CDB6L2D1 CDB6L2D3 CDB6L2D6 CDB6L2D10 CDB6L2D16 CDB6L2D20 CDB6L2D25 CDB6L2D32 CDB6L2D40 CDB6L2D50 CDB6L2D63 CDB6a3D1 CDB6a3D3 CDB6a3D6 CDB6a3D10 CDB6a3D16 CDB6a3D20 CDB6a3D25 CDB6a3D32 CDB6a3D40 CDB6a3D50 CDB6a3D63 CDB6L3D1 CDB6L3D3 CDB6L3D6 CDB6L3D10 CDB6L3D16 CDB6L3D20 CDB6L3D25 CDB6L3D32 CDB6L3D40 CDB6L3D50 CDB6L3D63 CDB6a4D1 CDB6a4D3 CDB6a4D6 CDB6a4D10 CDB6a4D16 CDB6a4D20 CDB6a4D25 CDB6a4D32 CDB6a4D40 CDB6a4D50 CDB6a4D63
Final Distribution

RoHS

Type

3P

4.5

4P

Note: Width refers to multiple of 9 mm.

CDB6 18mm Miniature Circuit Breaker


Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000 /4500A Order Information
Type Breaking Capacity (kA) 4.5 Rating Width (A) Reference B curve CDB6L4B1 CDB6L4B3 CDB6L4B6 CDB6L4B10 CDB6L4B16 CDB6L4B20 CDB6L4B25 CDB6L4B32 CDB6L4B40 CDB6L4B50 CDB6L4B63 C curve CDB6L4C1 CDB6L4C3 CDB6L4C6 CDB6L4C10 CDB6L4C16 CDB6L4C20 CDB6L4C25 CDB6L4C32 CDB6L4C40 CDB6L4C50 CDB6L4C63 D curve CDB6L4D1 CDB6L4D3 CDB6L4D6 CDB6L4D10 CDB6L4D16 CDB6L4D20 CDB6L4D25 CDB6L4D32 CDB6L4D40 CDB6L4D50 CDB6L4D63

RoHS

1 8 3 8 6 8 10 8 16 8 20 8 25 8 32 8 40 8 50 8 63 8 Note: Width refers to multiple of 9 mm.

Final Distribution

Technical Data
MCB CDB6 18mm Circuit Breaker Standard Certification Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Rate current(A) 1-63 Poles 1P 2P, 3P, 4P IEC60898-1 CB, CE, RoHS 1-4P 1,3,6,10,16,20,25,32,40,50,63A 230/400V AC 500V Breaking Capacity Icn Electrical Features Voltage(V) 230/400 400 Breaking capactiy Icn(KA) 3/4.5 3/4.5

Tripping Curve(see following tripping curve pictures) B Curve:the magnetic release operates between 3 and 5 In C Curve:the magnetic release operates between 5 and 10 In D Curve:the magnetic release operates between 10 and 14 In Electrical Durability Mechanical Durability Protection Degree Tropicalization Ambient Temperature 4000 times 10000 times 2 treatment 2 ~ 5+ 40
2

Mechanical Features

Connection Rate Current(A) 1-63 Mounting Accessories

Up to 25mm cables Screw Rated Torque (Nm) 2.5 35mm Din-rail Contact Accessory Fault-indicating Accessory Shunt -trip release OF SD MX+OF Limiting Torque (Nm) 4.5

Installation

M5

CDB6 18mm Miniature Circuit Breaker


Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000 /4500A Tripping Curve

RoHS

CDB6 Miniature Circuit Breaker

Final Distribution

Overall Dimensions

The Sketch Map of Installation with Breakers

Accessory

SD

OF

CDB6

MX+OF

CDB6s 18mm Miniature Circuit Breaker


Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500 /6000A

Function

CDB6s miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Order Information
Type 1P Rating Width (A) 1 2 3 4 5 6 8 10 13 16 20 25 32 40 50 63 2P 1 2 3 4 5 6 8 10 13 16 20 25 32 40 50 63 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Reference B curve CDB6s1B1 CDB6s1B2 CDB6s1B3 CDB6s1B4 CDB6s1B5 CDB6s1B6 CDB6s1B8 CDB6s1B10 CDB6s1B13 CDB6s1B16 CDB6s1B20 CDB6s1B25 CDB6s1B32 CDB6s1B40 CDB6s1B50 CDB6s1B63 CDB6s2B1 CDB6s2B2 CDB6s2B3 CDB6s2B4 CDB6s2B5 CDB6s2B6 CDB6s2B8 CDB6s2B10 CDB6s2B13 CDB6s2B16 CDB6s2B20 CDB6s2B25 CDB6s2B32 CDB6s2B40 CDB6s2B50 CDB6s2B63 C curve CDB6s1C1 CDB6s1C2 CDB6s1C3 CDB6s1C4 CDB6s1C5 CDB6s1C6 CDB6s1C8 CDB6s1C10 CDB6s1C13 CDB6s1C16 CDB6s1C20 CDB6s1C25 CDB6s1C32 CDB6s1C40 CDB6s1C50 CDB6s1C63 CDB6s2C1 CDB6s2C2 CDB6s2C3 CDB6s2C4 CDB6s2C5 CDB6s2C6 CDB6s2C8 CDB6s2C10 CDB6s2C13 CDB6s2C16 CDB6s2C20 CDB6s2C25 CDB6s2C32 CDB6s2C40 CDB6s2C50 CDB6s2C63 D curve CDB6s1D1 CDB6s1D2 CDB6s1D3 CDB6s1D4 CDB6s1D5 CDB6s1D6 CDB6s1D8 CDB6s1D10 CDB6s1D13 CDB6s1D16 CDB6s1D20 CDB6s1D25 CDB6s1D32 CDB6s1D40 CDB6s1D50 CDB6s1D63 CDB6s2D1 CDB6s2D2 CDB6s2D3 CDB6s2D4 CDB6s2D5 CDB6s2D6 CDB6s2D8 CDB6s2D10 CDB6s2D13 CDB6s2D16 CDB6s2D20 CDB6s2D25 CDB6s2D32 CDB6s2D40 CDB6s2D50 CDB6s2D63

Final Distribution

Note: Width refers to multiple of 9 mm.


8

CDB6s 18mm Miniature Circuit Breaker


Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500 /6000A

Order Information
Type 3P Rating Width (A) 1 2 3 4 5 6 8 10 13 16 20 25 32 40 50 63 4P 1 2 3 4 5 6 8 10 13 16 20 25 32 40 50 63 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Reference B curve CDB6s3B1 CDB6s3B2 CDB6s3B3 CDB6s3B4 CDB6s3B5 CDB6s3B6 CDB6s3B8 CDB6s3B10 CDB6s3B13 CDB6s3B16 CDB6s3B20 CDB6s3B25 CDB6s3B32 CDB6s3B40 CDB6s3B50 CDB6s3B63 CDB6s4B1 CDB6s4B2 CDB6s4B3 CDB6s4B4 CDB6s4B5 CDB6s4B6 CDB6s4B8 CDB6s4B10 CDB6s4B13 CDB6s4B16 CDB6s4B20 CDB6s4B25 CDB6s4B32 CDB6s4B40 CDB6s4B50 CDB6s4B63 C curve CDB6s3C1 CDB6s3C2 CDB6s3C3 CDB6s3C4 CDB6s3C5 CDB6s3C6 CDB6s3C8 CDB6s3C10 CDB6s3C13 CDB6s3C16 CDB6s3C20 CDB6s3C25 CDB6s3C32 CDB6s3C40 CDB6s3C50 CDB6s3C63 CDB6s4C1 CDB6s4C2 CDB6s4C3 CDB6s4C4 CDB6s4C5 CDB6s4C6 CDB6s4C8 CDB6s4C10 CDB6s4C13 CDB6s4C16 CDB6s4C20 CDB6s4C25 CDB6s4C32 CDB6s4C40 CDB6s4C50 CDB6s4C63 D curve CDB6s3D1 CDB6s3D2 CDB6s3D3 CDB6s3D4 CDB6s3D5 CDB6s3D6 CDB6s3D8 CDB6s3D10 CDB6s3D13 CDB6s3D16 CDB6s3D20 CDB6s3D25 CDB6s3D32 CDB6s3D40 CDB6s3D50 CDB6s3D63 CDB6s4D1 CDB6s4D2 CDB6s4D3 CDB6s4D4 CDB6s4D5 CDB6s4D6 CDB6s4D8 CDB6s4D10 CDB6s4D13 CDB6s4D16 CDB6s4D20 CDB6s4D25 CDB6s4D32 CDB6s4D40 CDB6s4D50 CDB6s4D63
Final Distribution

Note: Width refers to multiple of 9 mm.

CDB6s 18mm Miniature Circuit Breaker


Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500 /6000A Technical Data
MCB Standard Certitication
Final Distribution

CDB6s 18mm Circuit Breaker IEC 60898-1 KEMA CB CE RoHS


1-4P 1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63A 230/400V AC

poles Rated Current In Rated Voltage Ue Insulation Voltage Ui

500V AC Breaking Capacity Icn

Electrical Features

Rate current(A)

Breaking capacity lcn(kA)

Type

Poles 1P 2P, 3P, 4P 1P 2P, 3P, 4P 1P 2P, 3P, 4P

Voltage (V) 230/400 400 230/400 400 230/400 400

1-40 50,63 1-63

6 4.5 4.5

B,C B,C D

Tripping Curve ( see following tripping curve pictures)

B curve;the magnetic release operates between 3 and 5 In C curve;the magnetic release operates between 5 and 10 In D curve;the magnetic release operates between 10 and 14 In
Electrical Durability

4000 times 10000 times 2 treatment 2


~ -5+ 40

Mechanical Features

Mechanical Durability

Protection Degree Tropicalization Ambient Temperture

Connection
Rate current(A)

Up to 25mm2 cables
Screw Rated Torque (Nm) Limiting Torque (Nm)

Installation

1-63 Mounting Contact Accessory Accessories

M5

2.5 35mm Din-rail OF SD MX+OF

4.5

Fault-indicating Accessory Shunt-trip Release

10

CDB6s 18mm Miniature Circuit Breaker


Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500 /6000A

Tripping Curves

Final Distribution

Overall Dimensions
Unit: mm
: 67.210.43

Accessory

88 max

SD

OF

CDB6s

MX+OF

11

CDB2 27mm Miniature Circuit Breaker


Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A

Function

CDB2 miniature circuit breaker combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Order Information
Type 1P Rating (A) 63 80 100 125 Width (in mod.of 9mm) 3 3 3 3 Reference C curve CDB2H1C63 CDB2H1C80 CDB2H1C100 CDB2H1C125 D curve CDB2H1D63 CDB2H1D80 CDB2H1D100 CDB2H1D125

Final Distribution

2P

63 80 100 125

6 6 6 6

CDB2H2C63 CDB2H2C80 CDB2H2C100 CDB2H2C125

CDB2H2D63 CDB2H2D80 CDB2H2D100 CDB2H2D125

3P

63 80 100 125

9 9 9 9

CDB2H3C63 CDB2H3C80 CDB2H3C100 CDB2H3C125

CDB2H3D63 CDB2H3D80 CDB2H3D100 CDB2H3D125

4P

63 80 100 125

12 12 12 12

CDB2H4C63 CDB2H4C80 CDB2H4C100 CDB2H4C125

CDB2H4D63 CDB2H4D80 CDB2H4D100 CDB2H4D125

12

CDB2 27mm Miniature Circuit Breaker


Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Technical Data
MCB
Standard Certification Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui CDB2 27mm Circuit Breaker IEC60947-2 CB, SEMKO, CE
Final Distribution

1-4P 63,80,100,125A 230/400V AC 500V Breaking Capacity Icn

Electrical Features
Rating (A) 63~125 Poles

Voltage (V) 230 400

Breaking capacity (kA) 10 10

1P 2P,3P,4P

Tripping Curve (see following tripping curve pictures) C curve the magnetic release operates between 5 and 10 In D curve the magnetic release operates between 10 and 14 In Electrical Durability

Mechanical Features

Mechanical Durability Protection Degree Tropicalization Ambient Temperature 2 treatment 2 5+40 ~


2

Connection
Rate current(A)

Up to 50mm cables Screw Rated Torque (Nm) 4 35mm Din-rail Contact Accessory: Shunt-trip Release: OF MX+OF Limiting Torque (Nm) 5.5

Installation

63-125

M7

Mounting Accessories

13

CDB2 27mm Miniature Circuit Breaker


Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Tripping Curves

Final Distribution

Overall Dimensions

Accessories

MX+OF

OF

CDB2

14

CDB3 Phase-neutral Circuit Breaker


Standard: IEC 60898-1 Trip Curve: C curves Breaking Capacity: 3000A

Function

CDB3 phase-neutral circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Order Information

Final Distribution

1P+N

6 10 16 20 25 32

2 2 2 2 2 2

CDB3a5C6 CDB3a5C10 CDB3a5C16 CDB3a5C20 CDB3a5C25 CDB3a5C32

Technical Data
MCB Standard Certification Poles Rated Current In Electrical Features Rated Voltage Ue Insulation Voltage Ui
Breaking Capacity Icn

CDB3 18mm Circuit Breaker IEC60898-1 CE 1P+N 6,10,16,20,25,32A 230V AC 500V 3KA

Tripping Curve (see following tripping curve pictures)

C curve:the magnetic release operates between 5 and 10In Electrical Durability Mechanical Durability Mechanical Features Protection Degree Tropicalization Ambient Temperature Connection Installation Mounting Rate current(A) 6-32 Screw M4 4000 times 16000 times 2 treatment 2 5~+40 Up to 10mm cables
2

Rated Torque (Nm) 2

Limiting Torque (Nm) 3

35mm Din-rail

15

CDB3 Phase-neutral Circuit Breaker


Standard: IEC 60898-1 Trip Curve: C curves Breaking Capacity: 3000A

Tripping Curves
10000 5000 1h 2000 1000 500 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0.002 0.001 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200

Final Distribution

Overall Dimensions

16

CDB5 Switch Disconnector


Standard: IEC 60947-3

Function

CDB5 switch disconnectors combine the following functions: combine the following functions: Making and breaking normal load circuits Isolation

Order Information
Type 1P Voltage (V) 230 Rating (A) 20 32 63 100 Width (in mod.of 9mm) 2 2 2 2 Reference CDB5120 CDB5132 CDB5163 CDB51100
Final Distribution

2P

400

20 32 63 100

4 4 4 4

CDB5220 CDB5232 CDB5263 CDB52100

3P

400

20 32 63 100

6 6 6 6

CDB5320 CDB5332 CDB5363 CDB53100

4P

400

20 32 63 100

8 8 8 8

CDB5420 CDB5432 CDB5463 CDB54100

17

CDB5 Switch Disconnector


Standard: IEC 60947-3

Technical Data
Switch Disconnector Standard Poles Rated Current In Rated Voltage Ue Electrical Features Insulation Voltage Ui Rated Short-circuit Making Capacity Short-time Withstand Capacity for 1s Electrical Durability Mechanical Durability Mechanical Features Protection Degree Ambient Temperature Tropicalization Storage Temperature Connection Rate current(A) 20-100
2

CDB5 Switch Disconnector IEC60947-3 1-4P 20 63 32 100A 230/400V AC 500V


1066A(Ie:20~63A) 1692A(Ie:100A), Peak current 756A(Ie:20~63A) 1200A(Ie:100A),1s

Final Distribution

1500 times 8500 times 2 5~+40 treatment 2 -25~+55

Up to 50mm cables Screw M7 Rated Torque (Nm) 4 35mm Din-rail Limiting Torque (Nm) 5.5

Installation

Mounting

Overall Dimensions

18

Residual Current Devices Overview

18mm RCBO

Add-on RCD

Final Distribution

CDB6LE In: 6-60A

20

CDB6v Sensitivity: 30,100,300mA In: V32A, V63A

23

Sensitivity: 30,50,100,200,300mA Breaking Capacity: 3kA Poles: 1P+N, 2P, 3P, 3P+N, 4P

Poles: 1P+N, 2P, 3P, 3P+N, 4P

27mm RCBO

Phase-neutral RCBO

CDB2LE

26

CDB3LE Sensitivity: 30mA In: 6-40A Breaking Capacity: 4.5kA Poles: 1P+N

29

Sensitivity: 30,100,300mA In: 63-100A Breaking Capacity: 10kA Poles: 1P+N, 2P, 3P, 3P+N, 4P

RCCB

CDL7 Sensitivity:10,30,100,300mA In: 25-100A Poles: 2P,4P

31

19

CDB6LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 3000A Sensitivity: 30,50,100,200,300mA

Function

CDB6LE electronic type residual current operated circuit breakers combine the following functions: Overload protection Protection against short-circuit current Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Isolation

Final Distribution

Order Information
Type 1P+N Voltage (V) 230 Sensitivity (mA) 30 Rating (A) 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 Width 5 5 5 5 5 5 6 6 6 7 7 7 7 7 7 8 8 8 10 10 10 10 10 10 12 12 12 11 11 11 11 11 11 14 14 14 Reference C curve CDB6LEa1C6S CDB6LEa1C10S CDB6LEa1C16S CDB6LEa1C20S CDB6LEa1C25S CDB6LEa1C32S CDB6LEa1C40S CDB6LEa1C50S CDB6LEa1C60S CDB6LEa2C6S CDB6LEa2C10S CDB6LEa2C16S CDB6LEa2C20S CDB6LEa2C25S CDB6LEa2C32S CDB6LEa2C40S CDB6LEa2C50S CDB6LEa2C60S CDB6LEa3C6S CDB6LEa3C10S CDB6LEa3C16S CDB6LEa3C20S CDB6LEa3C25S CDB6LEa3C32S CDB6LEa3C40S CDB6LEa3C50S CDB6LEa3C60S CDB6LEa6C6S CDB6LEa6C10S CDB6LEa6C16S CDB6LEa6C20S CDB6LEa6C25S CDB6LEa6C32S CDB6LEa6C40S CDB6LEa6C50S CDB6LEa6C60S D curve CDB6LEa1D6S CDB6LEa1D10S CDB6LEa1D16S CDB6LEa1D20S CDB6LEa1D25S CDB6LEa1D32S CDB6LEa1D40S CDB6LEa1D50S CDB6LEa1D60S CDB6LEa2D6S CDB6LEa2D10S CDB6LEa2D16S CDB6LEa2D20S CDB6LEa2D25S CDB6LEa2D32S CDB6LEa2D40S CDB6LEa2D50S CDB6LEa2D60S CDB6LEa3D6S CDB6LEa3D10S CDB6LEa3D16S CDB6LEa3D20S CDB6LEa3D25S CDB6LEa3D32S CDB6LEa3D40S CDB6LEa3D50S CDB6LEa3D60S CDB6LEa6D6S CDB6LEa6D10S CDB6LEa6D16S CDB6LEa6D20S CDB6LEa6D25S CDB6LEa6D32S CDB6LEa6D40S CDB6LEa6D50S CDB6LEa6D60S

2P

230

30

3P

400

30

3P+N

400

30

Note: 1. Width refers to multiple of 9 mm. 2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with "W",100mA is marked with "Y",200mA is marked with "R",300mA is marked with "T".

20

CDB6LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 3000A Sensitivity: 30,50,100,200,300mA

Order Information
Type 4P Voltage (V) 400 Sensitivity (mA) 30 Rating (A) 6 10 16 20 25 32 40 50 60 Width 13 13 13 13 13 13 16 16 16 Reference C curve CDB6LEa4C6S CDB6LEa4C10S CDB6LEa4C16S CDB6LEa4C20S CDB6LEa4C25S CDB6LEa4C32S CDB6LEa4C40S CDB6LEa4C50S CDB6LEa4C60S

D curve CDB6LEa4D6S CDB6LEa4D10S CDB6LEa4D16S CDB6LEa4D20S CDB6LEa4D25S CDB6LEa4D32S CDB6LEa4D40S CDB6LEa4D50S CDB6LEa4D60S

Final Distribution

Note: 1. Width refers to multiple of 9 mm. 2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with "W",100mA is marked with "Y",200mA is marked with "R",300mA is marked with "T".

Technical Data
RCBO CDB6LE Residual Current Operated Circuit Breaker Standard Electronic Type Poles Electrical Features Rated Current In Rated Voltage Ue Insulation Voltage Ui Breaking Capacity Sensitivity IEC 61009-1 AC 1P+N,2P,3P,3P+N,4P 6,10,16,20,25,32,40,50,60A 230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P 500V 3KA 30,50,100,200,300mA

Tripping Curve(see following tripping curve pictures)

C curve:the magnetic release operates between 5 and 10 D curve:the magnetic release operates between 10 and 14
Electrical Durability Mechanical Features Mechanical Durability Protection Degree Tropicalization Ambient Temperature Connection
2

2000 times 2000 times 2 treatment 2 -5~+40

Rate current(A) Installation 6-32 40-60 Mounting Accessories

6-32A,Up to 16mm cables, 40-60A,Up to 25mm2 cables Screw Rated Torque Limiting Torque

(Nm) M4 M5 2.0 2.5 35mm Din-rail

(Nm) 3.0 4.5

OF Contact Accessory: Fault-indicating Accessory: SD

21

CDB6LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 3000A Sensitivity: 30,50,100,200,300mA

Tripping Curves

Final Distribution

Overall Dimensions

Accessories

SD

OF

CDB6LE

22

CDB6v Residual Current Protection Module


Standard: IEC 61009-1 Electronic type: AC Sensitivity: 30,100,300mA

Function

CDB6v can be assembled with CDB6s to be residual current breaker overcurrent Protection of persons against indirect contacting Supplementary protection of persons against direct contacting Prevention of electric-caused fire Overvoltage protection by products marked "G"
Final Distribution

Order Information
Frame V32 Type 1P+N Voltage (V) 230 Sensitivity (mA) 30 100 300 2P 400 30 100 300 3P 30 100 300 3P+N 30 100 300 4P 30 100 300 V63 1P+N 230 30 100 300 2P 400 30 100 300 3P 30 100 300 3P+N 30 100 300 4P 30 100 Note: Width refers to mutultiple of 9mm. 300 Width 5 5 5 7 7 7 10 10 10 11 11 11 13 13 13 6 6 6 8 8 8 12 12 12 14 14 14 16 16 16 Reference CDB6v321N CDB6v321NR100 CDB6v321NR300 CDB6v322P CDB6v322PR100 CDB6v322PR300 CDB6v323P CDB6v323PR100 CDB6v323PR300 CDB6v323N CDB6v323NR100 CDB6v323NR300 CDB6v324P CDB6v324PR100 CDB6v324PR300 CDB6v631N CDB6v631NR100 CDB6v631NR300 CDB6v632P CDB6v632PR100 CDB6v632PR300 CDB6v633P CDB6v633PR100 CDB6v633PR300 CDB6v633N CDB6v633NR100 CDB6v633NR300 CDB6v634P CDB6v634PR100 CDB6v634PR300

23

CDB6v Residual Current Protection Module


Standard: IEC 61009-1 Electronic type: AC Sensitivity: 30,100,300mA Technical Data
RCD Standard Electronic Type
Final Distribution

CDB6v Residual Current Protection Module IEC61009-1 AC 1P+N, 2P, 3P, 3P+N, 4P V32 In32A;V63 In63A 230/400V AC 500V A after CDB6s assembled with reference to CDB6s parameters 30,100,300mA On CDB6v is a residual opening current indication, which distinguish residual current from other faults Manual control:allows for two kinds of reset CDB6v resets at the same time with breaker CDB6v resets before breaker 280V5% AC,applicable to products with 1P+N and 2P 2000 times(In25A) 1000times(In25A) 1000 times(In>25A) 2000 times IP20 treatrment 2 ~ -5+40
2

Poles Rated Current In Rated Voltage Ue Rated Insulation Voltage Electrical Features Breaking Capacity Sensitivity Tripping Indication

Manual Control

G products offer overvoltage protection Electrical Durability Mechanical Features Mechanical Durability Protection Degree Tropicaliation Ambient Temperature Connection Rate current(A) V32 V63 Screw M4 M5

-Up to 16mm cables(V32) 2 -Up to 25mm cables(V63) Rated Torque (Nm) 2.2 2.5 Limiting Torque (Nm) 3.0 4.5

Installation

24

CDB6v Residual Current Protection Module


Standard: IEC 61009-1 Electronic type: AC Sensitivity: 30,100,300mA Overall Dimensions

Final Distribution

Pole 1P+N 2P 3P 3P+N 4P

V32 450.32 630.37 900.5 990.5 1170.57

V63 540.37 720.43 1080.57 1260.64 1440.72

Assembly

CDB6v can be assembled with CDB6s to be residual current breaker overcurrent Protection of persons against indirect contacting Supplementary protection of persons against direct contacting Prevention of electric-caused fire Overvoltage protection by products markedG

25

CDB2LE Residual Current Operated Circuit Breaker


Standard: IEC 60947-2 Electronic type: AC Breaking Capacity: 10000A Sensitivity: 30, 100, 300mA

Function

CDB2LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Protection of electrical installations against insulation faults (fire hazard, etc) Isolation

Final Distribution

Order Information
Type 1P+N Width 6 Sensitivity Rating (A) (mA) 30 30 30 100 100 100 300 300 300 30 30 30 100 100 100 300 300 300 30 30 30 100 100 100 300 300 300 30 30 30 100 100 100 300 300 300 63 80 100 63 80 100 63 80 100 63 80 100 63 80 100 63 80 100 63 80 100 63 80 100 63 80 100 63 80 100 63 80 100 63 80 100 Reference C curve CDB2LEH1C63S CDB2LEH1C80S CDB2LEH1C100S CDB2LEH1C63Y CDB2LEH1C80Y CDB2LEH1C100Y CDB2LEH1C63T CDB2LEH1C80T CDB2LEH1C100T CDB2LEH2C63S CDB2LEH2C80S CDB2LEH2C100S CDB2LEH2C63Y CDB2LEH2C80Y CDB2LEH2C100Y CDB2LEH2C63T CDB2LEH2C80T CDB2LEH2C100T CDB2LEH3C63S CDB2LEH3C80S CDB2LEH3C100S CDB2LEH3C63Y CDB2LEH3C80Y CDB2LEH3C100Y CDB2LEH3C63T CDB2LEH3C80T CDB2LEH3C100T CDB2LEH6C63S CDB2LEH6C80S CDB2LEH6C100S CDB2LEH6C63Y CDB2LEH6C80Y CDB2LEH6C100Y CDB2LEH6C63T CDB2LEH6C80T CDB2LEH6C100T D curve CDB2LEH1D63S CDB2LEH1D80S CDB2LEH1D100S CDB2LEH1D63Y CDB2LEH1D80Y CDB2LEH1D100Y CDB2LEH1D63T CDB2LEH1D80T CDB2LEH1D100T CDB2LEH2D63S CDB2LEH2D80S CDB2LEH2D100S CDB2LEH2D63Y CDB2LEH2D80Y CDB2LEH2D100Y CDB2LEH2D63T CDB2LEH2D80T CDB2LEH2D100T CDB2LEH3D63S CDB2LEH3D80S CDB2LEH3D100S CDB2LEH3D63Y CDB2LEH3D80Y CDB2LEH3D100Y CDB2LEH3D63T CDB2LEH3D80T CDB2LEH3D100T CDB2LEH6D63S CDB2LEH6D80S CDB2LEH6D100S CDB2LEH6D63Y CDB2LEH6D80Y CDB2LEH6D100Y CDB2LEH6D63T CDB2LEH6D80T CDB2LEH6D100T

2P

3P

12

3P+N

12

Note: Width refers to multiple of 9mm .

26

CDB2LE Residual Current Operated Circuit Breaker


Standard: IEC 60947-2 Electronic type: AC Breaking Capacity: 10000A Sensitivity: 30, 100, 300mA Order Information
Type 4P Width 15 Sensitivity Rating (A) (mA) 30 30 30 100 100 100 300 300 300 63 80 100 63 80 100 63 80 100 Reference C curve CDB2LEH4C63S CDB2LEH4C80S CDB2LEH4C100S CDB2LEH4C63Y CDB2LEH4C80Y CDB2LEH4C100Y CDB2LEH4C63T CDB2LEH4C80T CDB2LEH4C100T D curve CDB2LEH4D63S CDB2LEH4D80S CDB2LEH4D100S CDB2LEH4D63Y CDB2LEH4D80Y CDB2LEH4D100Y CDB2LEH4D63T CDB2LEH4D80T CDB2LEH4D100T

Final Distribution

Note: Width refers to multiple of 9mm .

Technical Data
RCBO CDB2LE Residual Current Operated Circuit Breake r
Standard Electronic Type Poles Electrical Features Rated Current In Rated Voltage Ue Insulation Voltage Ui Breaking Capacity Sensitivity IEC60947-2 AC 1P+N,2P,3P,3P+N,4P 63,80,100A 230V for 1P+N; 400V for 2P/3P/3P+N/4P 500V 10KA 30,100,300mA

Tripping Curve ( see following tripping curve pictures) C curve:the magnetic release operated between 5 and 10 In D curve:the magnetic release operated between 10 and 14 In Electrical Durability Mechanical Durability Mechanical Features Protection Degree Tropicalization Ambient Temperature Connection Rate current(A) Installation 63-100 Screw 1500 times 8500 times 2 treatment 2 -5~+40

Up to 50mm2 cables Rated Torque (Nm) 4 Limiting Torque (Nm) 5.5

M7

Accessories

Contact Accessory: Shunt -trip Release:

OF MX+OF

27

CDB2LE Residual Current Operated Circuit Breaker


Standard: IEC 60947-2 Electronic type: AC Breaking Capacity: 10000A Sensitivity: 30, 100, 300mA

Tripping Curve
e

Final Distribution

Overall Dimensions

Accessories

MX+OF

OF

CDB2LE

28

CDB3LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 4500A Sensitivity: 30mA

Function

CDB3LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Additional protection for users against direct contacts (30mA) Protection of electrical installations against insulation faults (fire hazard, etc) Isolation

Final Distribution

Order Information
Type 1P+N Width (mm) 36 Rating(A) 6 10 16 20 25 32 40 Reference C curve CDB3LEL5C6S CDB3LEL5C10S CDB3LEL5C16S CDB3LEL5C20S CDB3LEL5C25S CDB3LEL5C32S CDB3LEL5C40S

Technical Data
RCBO CDB3LE Residual Current Operated Circuit Breaker Standard Electronic Type Poles Rated Current In Electrical Features Rated Voltage Ue Insulation Voltage Ui Breaking Capacity Sensitivity IEC61009-1 AC 1P+N 6,10,16,20,25,32,40A 230V AC 500V 4.5KA 30mA

Tripping Curve (see following tripping curve pictures) C curve:the magnetic release operates between 5 and 10 In Electrical Durability Mechanical Features Mechanical Durability Protection Degree Tropicalization Ambient Temperature Connection Installation Rate current(A) 6-40 2000 times 2000 times 2 treatment 2 -5~+40
2

Up to 16mm cables

Screw M5

Rated Torque (Nm) 2.5 35mm Din-rail

Limiting Torque (Nm) 4.5

Mounting

29

CDB3LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 4500A Sensitivity: 30mA

Tripping Curve

Final Distribution

Overall Dimensions

30

CDL7 Electromagnetic Type Residual Current Switch


Standard: IEC 61008 RCCB Type: A , AC Sensitivity: 10, 30, 100, 300mA

Function

CDL7 electromagnetic type residual current switch combine the following functions: Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc)

Order Information
Final Distribution

2P

10

16

25

40

63

80

100

10 30 100 300 10 30 100 300 10 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300 10 30 100 300 10 30 100 300 10 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300

CDL7210LA CDL7210SA CDL7210YA CDL7210TA CDL7216LA CDL7216SA CDL7216YA CDL7216TA CDL7225LA CDL7225SA CDL7225YA CDL7225TA CDL7240SA CDL7240YA CDL7240TA CDL7263SA CDL7263YA CDL7263TA CDL7280SA CDL7280YA CDL7280TA CDL72100SA CDL72100YA CDL72100TA CDL7410LA CDL7410SA CDL7410YA CDL7410TA CDL7416LA CDL7416SA CDL7416YA CDL7416TA CDL7425LA CDL7425SA CDL7425YA CDL7425TA CDL7440SA CDL7440YA CDL7440TA CDL7463SA CDL7463YA CDL7463TA CDL7480SA CDL7480YA CDL7480TA CDL74100SA CDL74100YA CDL74100TA

CDL7210LC CDL7210SC CDL7210YC CDL7210TC CDL7216LC CDL7216SC CDL7216YC CDL7216TC CDL7225LC CDL7225SC CDL7225YC CDL7225TC CDL7240SC CDL7240YC CDL7240TC CDL7263SC CDL7263YC CDL7263TC CDL7280SC CDL7280YC CDL7280TC CDL72100SC CDL72100YC CDL72100TC CDL7410LC CDL7410SC CDL7410YC CDL7410TC CDL7416LC CDL7416SC CDL7416YC CDL7416TC CDL7425LC CDL7425SC CDL7425YC CDL7425TC CDL7440SC CDL7440YC CDL7440TC CDL7463SC CDL7463YC CDL7463TC CDL7480SC CDL7480YC CDL7480TC CDL74100SC CDL74100YC CDL74100TC

4P

10

16

25

40

63

80

100

31

CDL7 Electromagnetic Type Residual Current Switch


Standard: IEC 61008 RCCB Type: A , AC Sensitivity: 10, 30, 100, 300mA Technical Data
RCCB CDL7 Electromagnetic Type Residual Current Switc h

Standard
Certification
Final Distribution

IEC61008 , KEMACB AC, A 2P4P , A 10,16,25,40,63,80,100P 230/400V AC 500V 10,30,100,300mA 1000 times 2000 times no Instantaneous, rated residual operated current unadjustable Mechanical indication in the front 2 Treatment 2 -25~+40 Up to 35mm cables(In63A Screw M5 Rated Torque (Nm) 2.0 35mm Din-rail Not need Limiting Torque (Nm) 4.5
2

Type Electrical Features Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Sensitivity Electrical Durability Mechanical Durability Overload or Short Circuit Protection Mechanical Features Tripping Indication Fault Curren Indicator Protection Degree Tropicalization Ambient Temperature Connection Up to 16mm Rate Installation current(A) 25-100 Mounting Power source Auxilary
2

Overall Dimensions

32

Accessory
CDB6,CDB6LE

The sketch map of installation with breakers

Final Distribution

SD

OF

Breaker

MX+OF

Remote Control Auxiliaries


OF contact auxiliary Indicate ON or OFF state of the breaker Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm cables
2

SD fault-indicating switch Sent out fault signal on the font when breaking down Indicator on the front to show fault trip Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables

Tripping Device
MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip once got signal Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables

Introductions
OF, SD must be assembled on the left ,one auxiliary only Each time only one auxiliary accepted in the left of MCB MX+OF must be assembled on the right, one MX+OF only CDB6LE can't assemble MX+OF

Order Information
type OF Width(mm) Voltage(V) 9 Reference CDB6OF

SD

CDB6SD

MX+OF

18 18 18 18 18 18 18

AC/DC 12V AC/DC 24V AC/DC 48V AC 110-130V AC 130V AC 230V AC 400V

CDB6MX12 CDB6MX24 CDB6MX48 CDB6MX110 CDB6MX130 CDB6MX230 CDB6MX400

33

Accessory
CDB6s

The sketch map of installation with breakers

Final Distribution

SD

OF

CDB6s

MX+OF

Remote Control Auxiliaries


OF contact auxiliary Indicate ON or OFF state of the breaker Basic type of auxiliary contact:1NO+1NC Connection:1-4mm2 cables SD fault-indicating switch Sent out fault signal when breaking down Indicator on the front to show fault trip Basic type of auxiliary contact:1NO+1NC Connection:1-4mm2 cables

Tripping Device
MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip while given signal Basic type of auxiliary contact:1NO+1NC Connection:1-4mm2 cables

Introductions
OF,SD must be assembled on the left ,one auxiliary only Each time only one auxiliary accepted in the left of MCB MX+OF must be assembled on the right, one MX+OF only CDB6s can't assemble MX+OF while assembled with CDB6v

Order Information
type OF Width(mm) Voltage(V) 9 Reference CDB6sOF

SD

CDB6sSD

MX+OF

18 1 18 18 18

AC/DC12-24V AC/DC24-48V AC110-127V AC230-400V

CDB6sMX24 CDB6sMX48 CDB6sMX110 CDB6sMX230

34

Accessory
CDB2,CDB2LE

The sketch map of installation with breakers

Final Distribution

MX+OF

OF

Breaker

Remote Control Auxiliaries


OF contact auxiliary Indicate ON or OFF state of the breaker Basic type of auxiliary contact:2NO+2NC Connection: 1-4mm2 cables

Introductions
MX+OF, OF must be assembled on the left Each time only one auxiliary accepted in the left of MCB

Tripping Device
MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip once got signal Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables

Order Information
Type OF Width(mm) Description 18 18 1NO 1NC 2NO 2NC Reference CDB2OF11 CDB2OF22

MX+OF

18 18 18

AC/DC24V AC48V~130V DC48V

CDB2MX24 CDB2MX48

AC230V-400V DC110V-130V CDB2MX230

35

Accessory
Busbar

Technical Data
Standard Material of busbar Material of insulation Short-circuit strength Nominal voltage Operating voltage Surge voltage Clima stability
Final Distribution

IEC 60664 E-CU-F25 PVC 50kA 415V Max 500V 4kV IEC 60068-2

Order Information
Type Thickness Section Max. Pole of pin cross current(A) (mm) (mm2) End feed-in 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.2 1.5 1.5 1.5 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 6 10 13 16 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 40 63 70 80 A 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 Reference CBB14012P CBB16315P CBB17015P CBB18015P CBB24012P CBB26315P CBB27015P CBB28015P CBB34012P CBB36315P CBB37015P CBB38015P CBB44012P CBB46315P CBB47015P CBB48015P CBB14012F CBB16315F CBB17015F CBB18015F CBB24012F CBB26315F CBB27015F CBB28015F CBB34012F CBB36315F CBB37015F CBB38015F CBB44012F CBB46315F CBB47015F CBB48015F Dimension(mm)

PIN-TYPE 1

U-TYPE

36

CDCH8 Modular Contactor


Standard: IEC 61095

Function

CDCH8 Modular Contactor provide: Automatic control on equipment in buildings Switch on or Swith off lighting or other equipments

Order Information
Final Distribution

Pole 2P

Current (A) 20 25

Voltage (V) 220V 230V 220V 230V

Reference CDCH8202M CDCH8202N CDCH8252M CDCH8252N

Technical Data
Building Control Command Devices CDCH8 Modular Contactor IEC 61095 KEMA CE CB AC-7a 230V AC 500V AC 20A/25A 20A/25A 4kw/5.4kw 1200times/h 9A/10A 1.2kw/1.4kw 30times/h AC-7b

Standard
Certification Type Rated Voltage Ue Rated Insulation Voltage Ui Conventional Thermal Current(I ) Rated Current(le) Rated power Operation Frequency Operation Time Making&Breaking capacity With stand Overcurrent Capacity Short-circuit Protection Ambient Temperature Connection Techenical Data of Coil Coil Voltage(Us) Allowable Voltage of Controlloop(V) Rated Power of Coil 1.5le

30000times 8le AC-7b,8le,10S Adapted to fuse :RT18-32X/32 Adapted to breaker :CDB6s-63/C32 -5+40 ~ Both 1 and 2 lines can be used CDCH8-20 1~2.5mm2, CDCH8-25,1~4mm2

220/230V AC Operating:85%~110%Us Release:20%~75%Us Start:16VA Holding:4VA Working power:1.4W

37

CDCH8 Modular Contactor


Standard: IEC 61095

Wiring Diagram

Final Distribution

Overall Dimensions

38

CDRT8 Time Relay


Standard:IEC 60947.5

Function

CDRT8 Time Relay provide: Disconnect Delay Connect Delay

Order Information
Final Distribution

Limit delay time 10 120 480 480

Delay type power delay power delay power delay off delay

Reference CDRT810B CDRT8120B CDRT8480B CDRT8480A

Technical Data
Building Control Command Devices
Standard Rated Voltage Ue Rated Current(le) Delay Type Limit Delay Time Conventional Thermal Current(l ) Timing Range
th

CDRT8 Time Relay


IEC 60947.5 230V AC 5A Off dalay Power delay 10s 120s 480s 8A

Contact Type Contact Number Rated Control Supply Voltage(Us) Operating Voltage Range Electrical Durability Rated Wattage Insulation Resistance Insulation Strength

Normally open contact 1 230V AC 85%-110%Us 30000 times 1W To each:AC 1760V 5s Disconnect between the contact position:AC 1000V 1min

Connection

up to 1mm2 cables

39

CDRT8 Time Relay


Standard:IEC 60947.5

Wiring Diagram

Final Distribution

Overall Dimensions

19max

68max

40

CDY1 Surge Protective Devices


Standard: IEC61643

Function

CDY1 surge protective devices provide: Applicable to household appliances and the like to offer protection When there is an over-voltage caused by either lightning strike or operation in the circuit

Order Information
Imax (kA) Imax Imax (kA) (kA) 20 Uc (V) Uc Uc (V) (V) 275 385 420 40 275 385 420 60 275 385 420 80 275 385 420 100 275 385 420 Up (kV) Up Up (kV) (kV) 1.3 1.5 1.8 1.5 1.8 2.0 1.8 2.2 2.5 2.0 2.2 2.5 2.2 2.5 2.5 Reference 1P Reference Reference 1P 1P CDY1201275 CDY1201385 CDY1201420 CDY1401275 CDY1401385 CDY1401420 CDY1601275 CDY1601385 CDY1601420 CDY1801275 CDY1801385 CDY1801420 CDY11001275 CDY11001385 CDY11001420 2P 2P 2P CDY1202275 CDY1202385 CDY1202420 CDY1402275 CDY1402385 CDY1402420 CDY1602275 CDY1602385 CDY1602420 CDY1802275 CDY1802385 CDY1802420 CDY11002275 CDY11002385 CDY11002420 3P 3P 3P CDY1203275 CDY1203385 CDY1203420 CDY1403275 CDY1403385 CDY1403420 CDY1603275 CDY1603385 CDY1603420 CDY1803275 CDY1803385 CDY1803420 CDY11003275 CDY11003385 CDY11003420 4P 4P 4P CDY1204275 CDY1204385 CDY1204420 CDY1404275 CDY1404385 CDY1404420 CDY1604275 CDY1604385 CDY1604420 CDY1804275 CDY1804385 CDY1804420 CDY11004275 CDY11004385 CDY11004420 1P+N 1P+N 1P+N CDY1205275 CDY1205385 CDY1205420 CDY1405275 CDY1405385 CDY1405420 CDY1605275 CDY1605385 CDY1605420 CDY1805275 CDY1805385 CDY1805420 CDY11005275 CDY11005385 CDY11005420 3P+N 3P+N CDY1206275 CDY1206385 CDY1206420 CDY1406275 CDY1406385 CDY1406420 CDY1606275 CDY1606385 CDY1606420 CDY1806275 CDY1806385 CDY1806420 CDY11006275 CDY11006385 CDY11006420

Final Distribution

41

CDY1 Surge Protective Devices


Standard: IEC61643

Technical Data
Type Pole Nominal discharge current In(8/20us) kA Maximum discharge current Imax(8/20us) kA Maximum continuous operational voltage Uc V Protection level Up kV Leakage current (75%Uc 1mA) uA Response time ns Standard: IEC 61643 Certification: SEMKO, CB CDY1-20 CDY1-40 CDY1-60 CDY1-80 40 80 CDY1-100 50 100

1P, 1P+N, 2P, 3P, 3P+N, 4P 10 20 30 20 40 60

Final Distribution

275 385 420 275 385 420 275 385 420 275 385 420 275 385 420 1.3 20 25 1.5 1.8 1.5 1.8 2.0 1.8 2.2 2.5 2.0 2.2 2.5 2.2 2.5 2.5

Overall Dimensions

42

CDPZ50 Series Lighting Distribution Box


Standard: IEC60439-1 IEC60670

Function

CDPZ50 series lighting distribution box provide: Protection against overload Protection against over voltage Protection against leakage

Order Information
Material Holistic steel-plastic Installation Surface installation No. of loop 6
8 12 16 20 Flush installation 24 6 8 12 16 20 24 No. of loop 4 6 8 12 15 18 24 36 4 6 8 12 15 18 24 36 4 6 8 12 15 18 24 36 4 6 8 12 15 18 24 36

Final Distribution

Reference CDPZ50M6
CDPZ50M8 CDPZ50M12 CDPZ50M16 CDPZ50M20 CDPZ50M24 CDPZ50R6 CDPZ50R8 CDPZ50R12 CDPZ50R16 CDPZ50R20 CDPZ50R24 Reference CDPZ50PM4IP30F CDPZ50PM6IP30F CDPZ50PM8IP30F CDPZ50PM12IP30F CDPZ50PM15IP30F CDPZ50PM18IP30F CDPZ50PM24IP30F CDPZ50PM36IP30F CDPZ50PR4IP30F CDPZ50PR6IP30F CDPZ50PR8IP30F CDPZ50PR12IP30F CDPZ50PR15IP30F CDPZ50PR18IP30F CDPZ50PR24IP30F CDPZ50PR36IP30F CDPZ50PM4IP30NF CDPZ50PM6IP30NF CDPZ50PM8IP30NF CDPZ50PM12IP30NF CDPZ50PM15IP30NF CDPZ50PM18IP30NF CDPZ50PM24IP30NF CDPZ50PM36IP30NF CDPZ50PR4IP30NF CDPZ50PR6IP30NF CDPZ50PR8IP30NF CDPZ50PR12IP30NF CDPZ50PR15IP30NF CDPZ50PR18IP30NF CDPZ50PR24IP30NF CDPZ50PR36IP30NF

Material Full plastic (fire-retardancy)

Installation Surface installation

Flush installation

Full plastic (Non fire-retardancy)

Surface installation

Flush installation

43

CDPZ50 Series Lighting Distribution Box


Standard: IEC60439-1 IEC60670

Technical Data
Type
Material Fire-resistancy Protection grade Rated operation voltage Rated insulated voltage Rated operating current Withstand current
Final Distribution

CDPZ50 Box:Metal, Cover:Plastic Fire-resistancy IP30 230/400V 500V 100A 6kA

CDPZ50P Full Plastic Optional

Overall Dimensions

Unit:mm

Surface installation CDPZ50 Holistic steel-plastic Loop number 6 8 12 16 20 24 CDPZ50P Full plastic Loop number 4 6 8 12 15 18 24 36 Surface installation A 110 147 183 255 310 362 270 270 B 200 200 200 200 200 218 324 459 Surface installation A 171 207 279 351 423 303 B 220 220 220 220 220 383

Flush installation

Flush installation A 163 199 272 343 413 282 B 200 200 200 200 200 364

Thickness C 90 90 90 90 90 90

Flush installation A 126 162 198 270 324 378 261 261 B 200 200 200 200 200 216 310 441

Thickness C 90 90 90 90 90 90 90 90

44

JXF Power Distribution Box


Standard: EN60529

Function
Order Information

JXF power distribution box provide: Control, monitering, measurement and protection for the electric power loops and main power controlling equipment.

(mm) Overall Installation Mounting plate Thick


JXF-2520/14 IP43 JXF-3025/14 IP43 JXF-3025/18 IP43 JXF-3030/14 IP43 JXF-3030/18 IP43 JXF-4030/14 IP43 JXF-4030/20 IP43 JXF-5040/14 IP43 JXF-5040/20 IP43 JXF-5040/25 IP43 JXF-6040/14 IP43 JXF-6040/20 IP43 JXF-6040/25 IP43 JXF-6050/14 IP43 JXF-6050/20 IP43 JXF-6050/25 IP43 JXF-7050/16 IP43 JXF-7050/20 IP43 JXF-7050/25 IP43 JXF-8060/20 IP43 JXF-8060/25 IP43 JXF-10080/20 IP43 JXF-10080/25 IP43 JXF-10080/30 IP43 JXF-2520/14 IP43 Improved JXF-3025/14 IP43 Improved JXF-3025/18 IP43 Improved JXF-3030/14 IP43 Improved JXF-3030/18 IP43 Improved JXF-4030/14 IP43 Improved JXF-4030/20 IP43 Improved JXF-5040/14 IP43 Improved JXF-5040/20 IP43 Improved JXF-5040/25 IP43 Improved JXF-6040/14 IP43 Improved JXF-6040/20 IP43 Improved JXF-6040/25 IP43 Improved JXF-6050/14 IP43 Improved JXF-6050/20 IP43 Improved JXF-6050/25 IP43 Improved JXF-7050/16 IP43 Improved JXF-7050/20 IP43 Improved JXF-7050/25 IP43 Improved JXF-8060/20 IP43 Improved JXF-8060/25 IP43 Improved JXF-10080/20 IP43 Improved JXF-10080/25 IP43 Improved JXF-10080/30 IP43 Improved 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 250 300 300 300 300 400 400 500 500 500 600 600 600 600 600 600 700 700 700 800 800 1000 1000 1000 250 300 300 300 300 400 400 500 500 500 600 600 600 600 600 600 700 700 700 800 800 1000 1000 1000 200 250 250 300 300 300 300 400 400 400 400 400 400 500 500 500 500 500 500 600 600 800 800 800 200 250 250 300 300 300 300 400 400 400 400 400 400 500 500 500 500 500 500 600 600 800 800 800 140 140 180 140 180 140 200 140 200 250 140 200 250 140 200 250 160 200 250 200 250 200 250 300 140 140 180 140 180 140 200 140 200 250 140 200 250 140 200 250 160 200 250 200 250 200 250 300 290 340 340 340 340 440 440 540 540 540 640 640 640 640 640 640 740 740 740 840 840 1040 1040 1040 290 340 340 340 340 440 440 540 540 540 640 640 640 640 640 640 740 740 740 840 840 1040 1040 1040 150 200 200 250 250 250 250 350 350 350 350 350 350 450 450 450 450 450 450 550 550 750 750 750 150 200 200 250 250 250 250 350 350 350 350 350 350 450 450 450 450 450 450 550 550 750 750 750 170 220 220 220 220 320 320 420 420 420 520 520 520 520 520 520 620 620 620 720 720 920 920 920 170 220 220 220 220 320 320 420 420 420 520 520 520 520 520 520 620 620 620 720 720 920 920 920 158 208 208 258 258 258 258 358 358 358 358 358 358 458 458 458 458 458 458 558 558 758 758 758 158 208 208 258 258 258 258 358 358 358 358 358 358 458 458 458 458 458 458 558 558 758 758 758 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 JXF252014 JXF302514 JXF302518 JXF303014 JXF303018 JXF403014 JXF403020 JXF504014 JXF504020 JXF504025 JXF604014 JXF604020 JXF604025 JXF605014 JXF605020 JXF605025 JXF705016 JXF705020 JXF705025 JXF806020 JXF806025 JXF1008020 JXF1008025 JXF1008030 JXF252014B JXF302514B JXF302518B JXF303014B JXF303018B JXF403014B JXF403020B JXF504014B JXF504020B JXF504025B JXF604014B JXF604020B JXF604025B JXF605014B JXF605020B JXF605025B JXF705016B JXF705020B JXF705025B JXF806020B JXF806025B JXF1008020B JXF1008025B JXF1008030B

Final Distribution

Lock

45

JXF Power Distribution Box


Standard: EN60529

Order Information
Dimension(mm) Overall Installation (mm) Mounting plate Thick JXF-2520/14 IP54 JXF-3025/14 IP54 JXF-3025/18 IP54 JXF-3030/14 IP54 JXF-3030/18 IP54 JXF-4030/14 IP54 JXF-4030/20 IP54 JXF-5040/14 IP54 JXF-5040/20 IP54 JXF-5040/25 IP54 JXF-6040/14 IP54 JXF-6040/20 IP54 JXF-6040/25 IP54 JXF-6050/14 IP54 JXF-6050/20 IP54 JXF-6050/25 IP54 JXF-7050/16 IP54 JXF-7050/20 IP54 JXF-7050/25 IP54 JXF-8060/20 IP54 JXF-8060/25 IP54 JXF-10080/20 IP54 JXF-10080/25 IP54 JXF-10080/30 IP54 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 250 300 300 300 300 400 400 500 500 500 600 600 600 600 600 600 700 700 700 800 800 1000 1000 1000 200 250 250 300 300 300 300 400 400 400 400 400 400 500 500 500 500 500 500 600 600 800 800 800 140 140 180 140 180 140 200 140 200 250 140 200 250 140 200 250 160 200 250 200 250 200 250 300 320 370 370 370 370 470 470 570 570 570 670 670 670 670 670 670 770 770 770 870 870 1070 1070 1070 150 200 200 250 250 250 250 350 350 350 350 350 350 450 450 450 450 450 450 550 550 750 750 750 215 265 265 265 265 365 365 465 465 465 565 565 565 565 565 565 665 665 665 765 765 965 965 965 148 198 198 248 248 248 248 348 348 348 348 348 348 448 448 448 448 448 448 548 548 748 748 748 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 JXF252014Q JXF302514Q JXF302518Q JXF303014Q JXF303018Q JXF403014Q JXF403020Q JXF504014Q JXF504020Q JXF504025Q JXF604014Q JXF604020Q JXF604025Q JXF605014Q JXF605020Q JXF605025Q JXF705016Q JXF705020Q JXF705025Q JXF806020Q JXF806025Q JXF1008020Q JXF1008025Q JXF1008030Q
Final Distribution

Lock

46

JXF Power Distribution Box


Standard: EN60529

Technical Data
Type
Protection grade Standard: Certificate Rated voltage Rated insulated voltage Rated operating current Withstand current Sheet thickness Hinge Sealing rubber gasket Cable gland JXF IP43
IP43 EN60529 CE 220/400V 660V 400A 15kA 1.0~1.5mm 1.0~1.5mm 1.0~1.5mm Enhanced Black rubber gasket bottom only 1.2~1.5mm 2.0mm Enhanced Black rubber gasket bottom only

JXF IP43 Improved


IP43

JXF IP54
IP54
Final Distribution

Mounting plate thickness 1.0~1.5mm


Normal Seal band Top and bottom

Overall Dimensions
Unit: mm

sealing rubber gasket

sealing rubber gasket

handle lock door


wall fixing bracket

box

hinge

47

Contents
Low-voltage Distribution

Molded Case Circuit Breaker


CDM1 CDMLE Molded Case Circuit Breaker Earth-Leakage Circuit Breaker

49-63
49 57

Air Circuit Breaker


CDW7 Air Circuit Breaker

64-82
64

Low-voltage Distribution

48

CDM1 Moulded Case Circuit Breaker


Standard: IEC 60947-2

Function

CDM1 moulded case circuit breaker provide: To distribute electric power To protect power line and equipments against overload, undervoltage and shortcircuit faults (In400A) To infrequently start and control AC motors

Order Information
Type CDM1-63 3P In A 10 16 20 25 32 40 50 63 10 16 20 25 32 40 50 63 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 Reference Type M CDM163M103 CDM163M163 CDM163M203 CDM163M253 CDM163M323 CDM163M403 CDM163M503 CDM163M633 CDM163M104 CDM163M164 CDM163M204 CDM163M254 CDM163M324 CDM163M404 CDM163M504 CDM163M634 CDM1100M162 CDM1100M202 CDM1100M252 CDM1100M322 CDM1100M402 CDM1100M502 CDM1100M632 CDM1100M802 CDM1100M1002 CDM1100M163 CDM1100M203 CDM1100M253 CDM1100M323 CDM1100M403 CDM1100M503 CDM1100M633 CDM1100M803 CDM1100M1003 CDM1100M164 CDM1100M204 CDM1100M254 CDM1100M324 CDM1100M404 CDM1100M504 CDM1100M634 CDM1100M804 CDM1100M1004 Type L CDM163L103 CDM163L163 CDM163L203 CDM163L253 CDM163L323 CDM163L403 CDM163L503 CDM163L633 -----------------CDM1100L163 CDM1100L203 CDM1100L253 CDM1100L323 CDM1100L403 CDM1100L503 CDM1100L633 CDM1100L803 CDM1100L1003 ----------

Low-voltage

Distribution

4P

CDM1-100

2P

3P

4P

49

CDM1 Moulded Case Circuit Breaker


Standard: IEC 60947-2

Order Information
Type CDM1-225 2P In A 100 125 160 180 200 225 100 125 160 180 200 225 100 125 160 180 200 225 200 225 250 315 350 400 200 215 250 315 350 400 400 500 630 400 500 630 400 500 630 700 800 400 500 630 700 800 700 800 1000 1250 Reference Type M CDM1225M1002 CDM1225M1252 CDM1225M1602 CDM1225M1802 CDM1225M2002 CDM1225M2252 CDM1225M1003 CDM1225M1253 CDM1225M1603 CDM1225M1803 CDM1225M2003 CDM1225M2253 CDM1225M1004 CDM1225M1254 CDM1225M1604 CDM1225M1804 CDM1225M2004 CDM1225M2254 CDM1400M2003 CDM1400M2253 CDM1400M2503 CDM1400M3153 CDM1400M3503 CDM1400M4003 CDM1400M2004 CDM1400M2254 CDM1400M2504 CDM1400M3154 CDM1400M3504 CDM1400M4004 CDM1630M4003 CDM1630M5003 CDM1630M6303 CDM1630M4004 CDM1630M5004 CDM1630M6304 CDM1800M4003 CDM1800M5003 CDM1800M6303 CDM1800M7003 CDM1800M8003 CDM1800M4004 CDM1800M5004 CDM1800M6304 CDM1800M7004 CDM1800M8004 CDM11250M7003 CDM11250M8003 CDM11250M10003 CDM11250M12503

3P

4P

CDM1-400

3P

4P

CDM1-630

3P

4P

CDM1-800

3P

4P

CDM1-1250 3P

Type L ------CDM1225L1003 CDM1225L1253 CDM1225L1603 CDM1225L1803 CDM1225L2003 CDM1225L2253 ------CDM1400L2003 CDM1400L2253 CDM1400L2503 CDM1400L3153 CDM1400L3503 CDM1400L4003 ------CDM1630L4003 CDM1630L5003 CDM1630L6303 ---CDM1800L4003 CDM1800L5003 CDM1800L6303 CDM1800L7003 CDM1800L8003 ----------

Low-voltage Distribution

Note: The connection mode for CDM1 is the fixed type front connection.

50

CDM1 Moulded Case Circuit Breaker


Standard: IEC 60947-2

Order Information for Assessories


Voltage (V) Type 230V AC 400V AC CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 CDM1-1250 Reference MN CDM163MN230* CDM163MN400* CDM1100MN230* CDM1100MN400* CDM1225MN230* CDM1225MN400* CDM1400MN230* CDM1400MN400* CDM1630MN230* CDM1630MN400* CDM1800MN230* CDM1800MN400* CDM11250MN230* CDM11250MN400*

MX CDM163MX230* CDM163MX400* CDM1100MX230* CDM1100MX400* CDM1225MX230* CDM1225MX400* CDM1400MX230* CDM1400MX400* CDM1630MX230* CDM1630MX400* CDM1800MX230* CDM1800MX400* CDM11250MX230* CDM11250MX400*

OF CDM163OF*

SD CDM163SD*

TR(Round Handle) TS(Square Handle) CDM163TR CDM163TS CDM1100TS CDM1225TS CDM1400TS CDM1630TS CDM1800TS
Low-voltage Distribution

CDM1100OF* CDM1100SD* CDM1100TR CDM1225OF* CDM1225SD* CDM1225TR CDM1400OF* CDM1400SD* CDM1400TR CDM1630OF* CDM1630SD* CDM1630TR CDM1800OF* CDM1800SD* CDM1800TR CDM11250OF*

Note 1: MN and MX could be sold with CDM1 product and installed by manufactory 2: *means the connecting type; Blank: terminal connection; D5: 500mm wire connection

9 8 10 7 11 1 2

12

5 4 3 13

1 2 3 4 5

Connection Phase partition Motor mechanism Round handle mechanism Quadrate handle mechanism

6 7 8 9 10

Shunt release contactor Undervoltage release contactor Plug-type conneding terminal Plug-type front connection Plug-type rear connection

11 12 13

Stationary type rear connection R Alarm contactor Auxiliary contactor

51

CDM1 Moulded Case Circuit Breaker


Standard: IEC 60947-2

Technical Data
Main technical parameters are shown in the table below MCCB standard MCCB Type Frame size rated current A Number of poles Rated frequency Hz Rated current In A
Low-voltage Distribution

CDM1 IEC 60947-2 KEMA,SEMKO,CB,CE CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 CDM1-1250 63 100 225 400 630 800 1250 3P,4P 50/60 10 16 20 25 32 40 50 63 690 6000 2P,3P,4P 3P,4P 3P 400 500 700 800 630 700 1000 800 1250

Rated insulation voltage Ui V Rated impulse withstand voltage Uimp V Rated operational voltage Ue V Icu kA Type M (400V) Type L Ics kA Type M (400V) Type L

16 20 100 125 200 350 400 500 25 30 160 180 250 315 630 32 40 200 225 400 50 63 80 100 800 690/750 8000 6000/8000

690 6000

400

400 / 690 50 35 30 26 120 1500 8500 40 50 50 35 30 26 120 1000 7000 60 75

400 70 50 40 30 100 60 1000 4000 40 110

50 25 30 18 Arcing distance mm 50 Durability Cycles/h 120 Electrical 4000 Mechanical 6000 Power consumpution (W) Fixed 25 Plug-in 30

400 690 65 45 42 34 60 1000 4000 150 200

400 70 50 40 30 20 500 2500 135 190 85 45 20 500 2500 240 300

Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The circuit breaker can be fixed type or plug-in type For 4-pole circuit breakers: N-pole without overcurrent release, it switches on and off with other poles ( N-pole lead-make, lag-break) Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the accessories part

52

CDM1 Moulded Case Circuit Breaker


Standard: IEC 60947-2

Accessories
The accessories are fixed into the circuit breaker. Remote tripping: MX or MN releases are used to trip the circuit breaker. This release trips the circuit breaker when the control voltage drops below the tripping threshold: Tripping threshold between 35% to 70% of the rated voltage Circuit-breaker closing is possible only if the voltage exceeds 85% of the rated voltage. Circuit-breaker tripping by an MN release meets the requirements of standard IEC 60947-2.
power source input

MN (Undervoltage Release)
Technical data Rated operating voltage Ue(V) Drop-out voltage(V) Pick-up voltage(V)

Low-voltage

Distribution

230V, 400V AC (0.35~0.7) Ue (0.85~1.1) Ue

MX shunt release: The MX release trips the circuit breaker when the control voltage rises above 0.7 x Un. Control signals can be of the impulse type (u 20 ms) or maintained.

MX (Shunt Release)
Technical data Rated control voltage US(V) Operating voltage(V)

power source input

230V, 400V AC (0.7~1.1) US

Indication contacts: These common-point changeover contacts can be used to remotely indicate circuit-breaker status information for indications, electrical locking, relays, etc. They comply with international standard IEC 60947-5. Functions: OF (ON/OFF): indicates the position of the circuit-breaker contacts. SD (trip indication): indicates that the circuit-breaker has tripped due to: v overload v short-circuit v operation of a voltage release v operation of thepush-to-trip button Returns to de-energised state when the circuit breaker is reset.

OF (Auxiliary Contactor)
Technical data Rated thermal current Ith 3A Rated operating current 1NO+1NC (Change over) 2NO+2NC (Change over)

0.4A (400V AC)

Auxiliary Contact wiring diagram

SD (Alarm Contactor)
Technical data Rated thermal current Ith 3A Rated operating current 1NO+1NC

Trip position

Arm Switch wiring diagram

0.26A (400V AC) 0.4A (400V AC)

53

CDM1 Moulded Case Circuit Breaker


Standard: IEC 60947-2

Overall Dimensions
Type CDM1-63L CDM1-63M CDM1-63M CDM1-100M CDM1-100L CDM1-100M CDM1-100M CDM1-225M CDM1-225L CDM1-225M
Low-voltage Distribution

Poles Overall Dimensions L 3 3 4 2 3 3 4 2 3 3 4 3 4 3 4 3 4 3 135 135 135 150 150 150 150 165 165 165 165 257 257 270 270 280 280 406 L1 21 21 21 51 51 51 51 64 64 64 64 W 76 76 103 65 92 92 122 75 107 107 142 H 89 99 99 103 87 103 103 124 108 124 124 146 146 160 160 146 146 190 H1 74 82 82 87 68 87 87 104 87 104 104 100 100 108 108 103 103 140.5 H2 21 28 28 24 25 24 24 24 24 24 24 36 36 41 41 34 34 58

Install dimensions a 25 25 25 -30 30 30 -35 35 35 44 44 58 58 70 70 70 b 117 117 117 129 129 129 129 126 126 126 126 215 215 200 200 243 243 375 d 3.5 3.5 3.5 4.5 4.5 4.5 4.5 5.5 5.5 5.5 5.5 6.5 6.5 7 7 7 7 10

CDM1-225M CDM1-400L,M CDM1-400M CDM1-630L,M CDM1-630M CDM1-800L,M CDM1-800M CDM1-1250M

105 140 105 184 118 118 182 240

102 210 102 280 104 210

Unit:mm

2P

3P

4P

e Overall and cut-out diagram of round handle

hinge

54

CDM1 Moulded Case Circuit Breaker


Standard: IEC 60947-2

Overall and cut-out diagram of square handle

hinge

Centrally revolvable type Unit:mm


Low-voltage Distribution

Dimension for handle mechanism(centrally revolvable type) A B Frame 117 25 CDM1-63 129 30 CDM1-100 126 35 CDM1-225 215 44 CDM1-400 200 58 CDM1-630 243 70 CDM1-800

H 49 54 54 76 83 76

Eccentrically rotating Unit:mm

Dimension for handle mechanism(eccentrically revolvable type) Frame CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 A 35 35 65 60 48 B 11.5 31 15 15 15 H 46 48 61 61 66
55

CDM1 Moulded Case Circuit Breaker


Standard: IEC 60947-2

Characteristic Curve of Circuit Breaker

max min min

max
min

max

Instantaneous current

Instantaneous current

Low-voltage Distribution
min

Delay trip

Instantaneous trip

Delay trip

Instantaneous trip Instantaneous trip

Delay trip

Instantaneous trip

Delay trip

For power distribution CDM1-63 Time / current characteristic curve

For power distribution CDM1-100 Time / current characteristic curve

For power distribution CDM1-225 Time / current characteristic curve

max

max

min

Delay trip Delay trip

Instantaneous trip Instantaneous trip

Delay trip Delay trip

Instantaneous trip Instantaneous trip

For power distribution

For power distribution

CDM1-400 Time / current characteristic curve CDM1-630 Time / current characteristic curve

56

CDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Function

Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The residual operating current value can be fixed or adjustable The residual operating current protection can be with time-delay or without time-delay Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the position indication contact, for detail see the accessories part

Coding System
Country code CD Product name M1LE Frame current 100 Breaking capacity M Current 16 Pole 3 Usage Residual current L N Pole A

Low-voltage

Distribution

100:100A 225:225A 400:400A

L: L type M: M type

16: 16A 400: 400A

3:3 pole 4:4 pole

Blank for distribution protection

S:30mA Y:100mA T:300mA F:500mA KY:30/100/500mA KT:100/300/500mA

For CDM1LE 4pole: A=A type (Direct connect) B=B type (Direct connect, lead-make, lag break)

57

CDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Order Information
Rated current In A 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 100 125 140 160 180 200 225 100 125 140 160 180 200 225 100 125 140 160 180 200 225 Reference Type M CDM1LE100M163 CDM1LE100M203 CDM1LE100M253 CDM1LE100M323 CDM1LE100M403 CDM1LE100M503 CDM1LE100M633 CDM1LE100M803 CDM1LE100M1003 CDM1LE100M164A CDM1LE100M204A CDM1LE100M254A CDM1LE100M324A CDM1LE100M404A CDM1LE100M504A CDM1LE100M634A CDM1LE100M804A CDM1LE100M1004A CDM1LE100M164B CDM1LE100M204B CDM1LE100M254B CDM1LE100M324B CDM1LE100M404B CDM1LE100M504B CDM1LE100M634B CDM1LE100M804B CDM1LE100M1004B CDM1LE225M1003 CDM1LE225M1253 CDM1LE225M1403 CDM1LE225M1603 CDM1LE225M1803 CDM1LE225M2003 CDM1LE225M2253 CDM1LE225M1004A CDM1LE225M1254A CDM1LE225M1404A CDM1LE225M1604A CDM1LE225M1804A CDM1LE225M2004A CDM1LE225M2254A CDM1LE225M1004B CDM1LE225M1254B CDM1LE225M1404B CDM1LE225M1604B CDM1LE225M1804B CDM1LE225M2004B CDM1LE225M2254B

Type CDM1LE-100 3P

4P A

4P B

CDM1LE-225 3P

4P A

4P B

Note:* express residual current.

Type L CDM1LE100L163 CDM1LE100L203 CDM1LE100L253 CDM1LE100L323 CDM1LE100L403 CDM1LE100L503 CDM1LE100L633 CDM1LE100L803 CDM1LE100L1003 CDM1LE100L164A CDM1LE100L204A CDM1LE100L254A CDM1LE100L324A CDM1LE100L404A CDM1LE100L504A CDM1LE100L634A CDM1LE100L804A CDM1LE100L1004A CDM1LE100L164B CDM1LE100L204B CDM1LE100L254B CDM1LE100L324B CDM1LE100L404B CDM1LE100L504B CDM1LE100L634B CDM1LE100L804B CDM1LE100L1004B CDM1LE225L1003 CDM1LE225L1253 CDM1LE225L1403 CDM1LE225L1603 CDM1LE225L1803 CDM1LE225L2003 CDM1LE225L2253 CDM1LE225L1004A CDM1LE225L1254A CDM1LE225L1404A CDM1LE225L1604A CDM1LE225L1804A CDM1LE225L2004A CDM1LE225L2254A CDM1LE225L1004B CDM1LE225L1254B CDM1LE225L1404B CDM1LE225L1604B CDM1LE225L1804B CDM1LE225L2004B CDM1LE225L2254B

Low-voltage Distribution

58

CDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Order Information
Rated current In A 200 250 315 350 400 200 225 250 315 350 400 4P B 200 225 250 315 350
Note:* express residual current.

Type CDM1LE-400 3P

Reference Type M CDM1LE400M2003 CDM1LE400M2503 CDM1LE400M3153 CDM1LE400M3503 CDM1LE400M4003 CDM1LE400M2004A CDM1LE400M2254A CDM1LE400M2504A CDM1LE400M3154A CDM1LE400M3504A CDM1LE400M4004A CDM1LE400M2004B CDM1LE400M2254B CDM1LE400M2504B CDM1LE400M3154B CDM1LE400M3504B CDM1LE400M4004B Type L CDM1LE400L2003 CDM1LE400L2503 CDM1LE400L3153 CDM1LE400L3503 CDM1LE400L4003 CDM1LE400L2004A CDM1LE400L2254A CDM1LE400L2504A CDM1LE400L3154A CDM1LE400L3504A CDM1LE400L4004A CDM1LE400L2004B CDM1LE400L2254B CDM1LE400L2504B CDM1LE400L3154B CDM1LE400L3504B CDM1LE400L4004B
Low-voltage Distribution

4P A

400

Order Information for Accessories


Voltage (V) 230V AC 400V AC Type Reference MN*

MX*

OF

SD

TS(Square Handle)

TR(Round Handle)

CDM1LE-100 CDM1LE100MN230* CDM1LE100MN400* CDM1LE-225 CDM1LE225MN230* CDM1LE225MN400* CDM1LE-400 CDM1LE400MN230*

CDM1LE100MX230* CDM1LE100OF* CDM1LE100SD* CDM1LE100TS CDM1LE100MX400* CDM1LE225MX230* CDM1LE225OF* CDM1LE225SD* CDM1LE225TS CDM1LE225MX400* CDM1LE400MX230* CDM1LE400OF* CDM1LE400SD* CDM1LE400TS

CDM1LE100TR CDM1LE225TR CDM1LE400TR

CDM1LE400MN400* CDM1LE400MX400* Note 1: MN and MX could be sold with CDM1LE product and installed by manufactory 2: *means the connecting type; Blank: terminal connection; D5: 500mm wire connection

59

CDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Technical Data
Type Frame size rated current A Rated current In A Rated frequency Hz Rated insulation voltage Ui V Rated operational voltage Ue V Number of poles Icu kA (400V) Ics kA (400V) Rated residual operating current In (mA) current In(mA) Durability Electrical Mechanical Total 1500 8500 10000 1000 7000 8000 1000 4000 5000 With delay Rated residual non-operating
Low-voltage Distribution

CDM1LE-100 100 16 20 25 32 40 50 63 80 100 50/60 800 400 3P, 4P Type M Type L Type M Type L 50 35 35 22 100/300/500 100/300/500 1/2 In

CDM1LE-225 225 100 125 140 160 180 200 225

CDM1LE-400 400 200 250 315 350 400

Rated impulse withstand voltage Uimp V 8000 50 35 35 22 30/100/500 100/300/500 100/300/500 1/2 In 100/300/500 1/2 In _ 50 _ 30 100/300/500

Without delay 30/100/500

Maximum break time for residual operating current protection Number of poles Max. break time S Without delay With delay In 0.2 0.5/1.15/2.15 2 In 0.1 0.35/1/2 5 In 0.04 0.25/0.9/1.9 10 In 0.04 0.25/0.9/1.9

Table for 4 pole CDM1LE (Neutral line) Code A B Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The residual operating current value can be fixed or adjusted fxed or adjusted The residual operating current protection can be with time-delay or without time-delay Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the accessories part Note N(direct connect) N(direct connect N pole lead-make, lag-break)

60

CDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Handle mechanism

Centrally revolvable type Unit:mm

Square Handle
Low-voltage Distribution

Dimension for handle mechanism Frame Dimension CDM1LE-100 49 CDM1LE-225 55 CDM1LE-400 74

Accessories
The accessories are fixed into the circuit breaker. Remote tripping: MX or MN releases are used to trip the circuit breaker. This release trips the circuit breaker when the control voltage drops below the trip ping threshold: tripping threshold between 0.35 and 0.7 times the rated voltage circuit-breaker closing is possible only if the voltage exceeds 0.85 times the rated voltage. Circuit-breaker tripping by an MN release meets the requirements of standard IEC 60947-2.

MN (Undervoltage Release)
Technical data Rated operating voltage Ue(V) Drop-out voltage(V) Pick-up voltage(V) 230V, 400V AC (0.35~0.7) Ue (0.85~1.1) Ue

Power source input

61

CDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

MX shunt release: The MX release trips the circuit breaker when the control voltage rises above 0.7 x Un. Control signals can be of the impulse type (u 20 ms) or maintained.

MX (Shunt Release)
Technical data Rated control voltage Us(V) Operating voltage(V)

230V, 400V AC (0.7~1.1) Us

Power source input


Indication contacts: These common-point changeover contacts can be used to remotely indicate circuit-breaker status information for indications, electrical locking, relays, etc. They comply with international standard IEC 60947-5. Functions: OF (ON/OFF): indicates the position of the circuit-breaker contacts. SD (trip indication): indicates that the circuit-breaker has tripped due to: v overload v short-circuit v operation of a voltage release v operation of thepush-to-trip button Returns to de-energised state when the circuit breaker is reset.

Low-voltage Distribution

OF (Auxiliary Contactor)
Technical data Rated thermal current Ith 3A Rated operating current 1NO+1NC (Change over) 2NO+2NC (Change over)

0.4A (400V AC)

Auxiliary Contact wiring diagram

SD (Alarm Contactor)
Trip position

Arm Switch wiring diagram

Technical data Rated thermal current Ith 3A Rated operating current 1NO+1NC

0.26A (400V AC) 0.4A (400V AC)

62

CDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Overall Dimensions
Unit:mm

Low-voltage

Distribution

Key to Overall Dimensions Type Poles Overall size L1 CDM1LE-100L 3 92max 4 122max CDM1LE-100M 3 92max 4 122max CDM1LE-225L 3 107max 4 142max CDM1LE-225M 3 107max 4 142max CDM1LE-400L,M 3 150max 4 198max L2 150max 150max 150max 150max 165max 165max 165max 165max 257max 257max L3 94max 94max 110max 110max 94max 94max 110max 110max 150max 150max L4 75max 75max 92max 92max 72max 72max 90max 90max 107max 107max Installation size a b d 30 129 44.5 60 129 64.5 30 129 44.5 60 129 64.5 35 126 44.5 70 126 64.5 35 126 44.5 70 126 64.5 48 194 44.5 95 194 66.5

63

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Application
Applied to power distribution of AC 50Hz/60Hz, rated operational voltage 400/690V, rated current 200A~6300A and lower For power distribution and protecting circuit and power supply equipment aganist harm from overload, undervoltage, short circuit, earthing, and other faults Circuit breaker which ampere frame size is under 630A can protect motor aganist overload,undervoltage and shortcircuit Core parts use intelligent control unit which has accurate discrimination protection, it can avoid unnecessary power failure and enhance the reliability of power supply system

Standard and Certification


Standard: IEC60947-2 Approved certification: CB, CE, KEMA
Low-voltage Distribution

Operating condition and installation recommendation


Ambiant temperature Ambient temperature shall be controlled between +40 and -5, the average temperature in 24 hours shall not exceed +35 Note:contacting manufacturer about circuit breaker used in place where ambient temperature is higher than +40 or lower than -5 Altitude of installation position shall not exceed than 2000m The relative humidity of the installation position shall not exceed 50% when the maximum temperature reached +40, but there can be higher relative humidity under lower temperature, for example, it can reach 90% at 20. Considering that condensation occurred on product surface when temperature changes Vertically mounting, tolerance on slope in any direction shall not exceed 5 Main circuit and undervoltage trip coil, power transformer primary coil: Auxiliary circuit,control circuit:

Altitude Environmental humidity

Degree of pollution Installation position Category of installation

64

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Parameter and characteristics


Certification approved: IEC 60947-1 IEC 60947-2 Type Number of poles Utilization categories Arc-over distance (mm) Rated opertional voltage (V) Rated insulation voltage (V) Rated impulse withstand voltage (V) Rated frequency (Hz) Rated current (A) In AC 400V AC 690V Rated service short circuit breaking capacity (kA) Rated short circuit making capacity (kA) Rated short circuit withstand current (kA) Service life(c/o cycles) Ics Icm Icw mechanical electrical AC 400V AC 690V AC 400V AC 690V AC 400V AC 690V Ue Ui Uimp CDW7-1000 3, 4 B 0 400 690 8000 50 200/400/630 /800/1000 Rated ultimate short circuit breaking capacity (kA) Icu 42 -30 -88 -30 -9000 1000 CDW7-2000 3, 4 B 0 400/690 800 8000 50 630/800/1000 /1250/1600/2000 65 50 50 40 176 105 40 40 9000 1000 CDW7-3200 3, 4 B 0 400/690 800 8000 50 2000/2500 /3200 80 65 80 50 220 143 50 50 4500 500 CDW7-6300 3, 4 B 0 400 800 8000 50 4000/5000 /6300 120 -100 -264 -85 -1500 500
Low-voltage Distribution

65

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Protection characteristics
structural feature of ESW series intelligent controller Interlocking device Floor plate Device Chassis Controller Sensor Accessories Power supply accessories Reset devise Magnetic flux converter Contactor Basic circuit Chassis and other units Mutual inductor AC power supply DC power supply UPS

Relay
Low-voltage Distribution

Outline and operation of ECW series intelligent controller ECWS-H (Applicable to CDW7-1000)
ELECTRIC

SEPECIFICATION
1-LCD interface display 2-Fault and alarm reset button 3-Fault/Alarm LED In normal state, this LED is off. In case of fault release, the red LED will flash quickly; in case of alarm, the red LED will be on constantly 4-Normal LED As long as the controller is on and operates normally, the green LED always flashes 5-Communication indicator The communication state indication is as follows: Profibus: OFF if no communication; ON if communication exists Modbus: OFF if no communication; flash if communication exists Device Net: Flash if no communication; ON if communication exists 6-Curve LEDs Red LEDs exist behind the curve. In case of fault release, the corresponding LED will flash indicating the fault type; During the parameter setting process, the LED is always on and indicates the current item.

ECWS-H 1

ECWS-H
Ir1 RESET Warn/ Alarm Ir2 Healthy Bus

2 3 4

5
Ir4 Isd Ir3

Keypad
7 8 9 10

11

12

13

14

7-Measure key l, used to switch to the default measurement menu. 8-Set key 2, used to switch to the parameter setting menu. 9-Protection Key 3, used to switch to the protection parameter setting menu. 10-Info key 4, used to switch to the historical record and maintenance menu. 11-Up, Move up the cursor through the menu items on the current level, or increment the value of the selected parameter. 12-Down, Move down the cursor through the menu items on the current level, or decrement the value of the selected parameter. 13-Exit, exit from the current level and return to the upper level, or cancel the current parameter selection. 14-Select, Select to enter into the next level from the current item, or select the current parameter, or store the change.

66

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

ECW-M(applicable to CDW72000/3200/6300)

SEPECIFICATION
1-Reset button of Fault release In case of breakers tripping, breakers cant be reclosed until this button is pressed. 2-voltmeter display Display the phase current ,normally display the Max.phase current. 3-lightemitting diode Indicators Display Setting , test , fault and Categorization 4-Ammeter display Display each of the phase current value and earth or leakage current value. Normally display Max. phase current value and can display the value of setting , test and fault current or time . 5-Key button Setting , test, check various state and Categorization 6-lighting clear or reset button When it is pressed ,the controller enters into normal run state , The breaker cant be closed until the button is pressed in case of setting, test, fault. 7-Shaft hole for test current 8-Shield As soon as the controller enters into normal run state ,the shield need to be sealed to protect the setting parameter.

ECW-M

Low-voltage

Distribution

67

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

ECW-H (enhanced type ,applicable to CDW7 2000/3200/6300)

SPECIFICATION
ELECTRIC

ECW-H

1 2

3 4
Ir1

RESET Warn/ Alarm Ir2 Healthy Bus

6
Ir4 Isd Ir3

1-Mechanical reset button(the button will pop up when fault tripping or test tripping, circuit breaker wont be closed without pressing down,when the button is pressed down,fault indication is reset immediately) 2-LCD display screen 3-Warn and alarm reset 4-Warn/ alarm LED When normally operated, LED is off When fault tripping , red LED will blink quickly When alarming, red LED is opening eternally 5-Healthy LED:green LED will blink continuously as long as the controller is energized and operating healthily 6-Communication lamp Communication status is indicated as follows Profibus:off when without communication,on uninterrupted when in communication Modbus:off when without communication,blinking when in communication Device Net:blinking when without communication,on uninterrupted when in communication 7-Curve LED A red LED lamp is hided in curve When triped by failure , the regarding LED will blink to indicate the failure type, when the protection reference is set, the lighting LED will indicate the set option 8-There is a 16pin test connector in the bottom of front plate of test terminal,you can insert a plug-in portable power box and inspection -unit

Low-voltage Distribution

Keypad
8
9-Measurement function key1, navigated to measurement default theme menu 10-Setting function key2, navigated to parameter setting theme menu 11-Protection function key3, navigated to protection parameter setting theme menu 12-Information function key4, navigated to history and maintenance theme menu 13-Move upwards from the current used level to change the menu content,or change the selected parameter 14-Move downwards from the current used level to change the menu content,or change the selected parameter 15-Exit the current used level to back the parent menu,or cancel the current parameter 16-Choose to enter the currrent programme leading to son menu,or select the current parameter, store the modification

TEST

10

11

12

13

14

15

16

68

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

ECW series intelligent controller function feature Intelligent controller function ECWS- H Basic function Protection Different curves available for long time delay protection Different curves available for inverse short time delay protection Definite short time delay protection Instantaneous protection Current unbalance (open phase) protection Earth protection Earth fault alarm Neutral phase protection Load monitor ECW - M Long time delay protection Definite time delay + inverse time delay for short time delay protection Instantaneous protection Earthing protection Load monitor Different curves available ECW - H for long time delay protection Different curves available for inverse short time delay protection Definite short time delay protection Instantaneous protection MCR and out-of-limit tripping protection Current unbalance (open phase) protection Earth protection Earth fault alarm Neutral phase protection Load monitor
note:* can measure voltage,frenquency,voltage unbalance rate,phase-sequency detection, power,energy,demand paramteter(current,power),harmonic

Addtional function* Measurement Four phase current (I1, I2, I 3, IN) and earth current Thermal capacity Maintenance Up to 8 fault logs Up to 8 alarm logs Up to 8 position logs Historical current peak Contact equivalence Number of operating cycles Clock function Self-diagnosis function
Low-voltage Distribution

Human-machine Digital LCD display of Chinese GUI LED indication Key operation MCR and out-of-limit tripping protection DO Signal alarm function Communication function

Max. phase current Four phase current (I1, I2, I 3, IN) and earth current

Fault log Self-diagnosis function Feature test function

Digital display LED indication Key operation Digital setting of protection parameters

DO Signal alarm function MCR and out-of-limit tripping protection Earth fault or leakage protection (either)

Four phase current (I1, I2, I 3, IN) and earth current Thermal capacity

Up to 8 fault logs Up to 8 alarm logs Up to 8 position logs Historical current peak Contact equivalence Number of operating cycles Fault clock function Self-diagnosis fault log Self-diagnosis function Feature test function

LCD display of Chinese Over-voltage protection GUI LED indication Key operation Under-voltage protection Voltage unbalance protection Over-currency protection Under-frequency protection Phase protection Inverse power protection Demand protection Zonal system interlock protection Communication function

69

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Basic protection Long time CDW7-1000 Basic configuration of ECW intelligent controller Current Setting Action conventional non-tripping 1.05Ir1 h 1.3Ir1 h 1.5Ir1 ECWS-H intelligent controllers Ir1=(0.4~1)ln 2h 2h ,144,224,320,480,640,800,9 60,1120 2.0Ir1
Low-voltage Distribution

CDW7-2000~6300 ECW-M intelligent controllers ECW-H intelligent controllers Ir1=(0.4~1)ln 2h 1h Ir1=(0.4~1)ln 2h 1h 15,30,60,120,240,360,480,60 0,720,840,960 8.4,16.9,33.8,67.5,135,270 8.4,16.9,33.8,67.5,135,202.5, 270,337.5,405,472.5,540

characteristics conventional tripping

8,12.8,19.2,32,48,64,80,108 15,30,60,120,240,480

3.32,5.32,8.00,13.32,20.00, 26.66,33.30,45.00,60.00,93. 32,133,200,266,333,400,43 3

3.0Ir1

1.25,2.00,3.00,5.00,7.50,10. 0,12.5,16.8,22.5,35.0,50.0,7 5.0,100,125,150,162

Short time Current setting Accuracy Action Inverse time-limit characteristics Definite time-delay Ir2=(1.5~15)In 15% Ts=K/10(N2-1),(Ts20ms) Time setting(S) 0.1,0.2,0.3,0.4 Resettable time(S) 0.06,0.13,0.2,0.27 Instantaneous Current setting Accuracy Earth fault Current setting Accuracy Action Inverse time-limit Time setting 0.1s~1s (Rank difference 0.1s) 0.1~0.4s (Rank difference 0.1s) 0.1s~1s(Rank difference 0.1s) characteristics Definite time-delay Ir4=(0.2~1.0)In 10% Ir4=(0.2~1.0)In 10% Ir4=(0.2~1.0)In 10% ECWS-H (1.0~20)ln 15% ECW-H Ir2=(0.4~15)In 10% I2Ts=(8Ir1)2ts 0.1,0.2,0.3,0.4 0.06,0.16,0.25,0.34 ECW-M CDW7-2000 15% CDW7-3200 15% CDW7-6300 15% Ir3=1In~50KA+OFF Ir3=1In~75KA+OFF IIr3=1In~100KA+OFF Ir2=(1.5~15)In 10% Ts=K/10(N2-1),(Ts20ms) 0.1,0.2,0.3,0.4 0.06,0.13,0.2,0.27

CDW7-1000~6300A

note:*pick-up shall not be crossed due to having three-stage protection simultaneously

70

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Auxiliary Functions
undervoltage release The undervoltage release automatically opens a circuit breaker when voltage drops to a value ranging between 35% to 70% of the line voltage. after tripping,the circuit breaker cannot be re-closed again when the voltage lowers than 35% or until returns to 85% of line voltage. Undervoltage release Rated operational voltage Operation voltage V V Range of closing voltage V Range of non-closing voltage Consumption CDW7-1000 CDW7-2000~6300 Ue V AC 380V (0.35~0.7)Ue (0.85~1.1)Ue 0.35Ue 36VA 5VA AC220V (0.35~0.7)Ue (0.85~1.1)Ue 0.35Ue 24VA 5VA
Low-voltage Distribution

Shunt release The shunt release shall open the circuit breaker when the supply drops to a value ranging between voltage rise between 70% to 110% of the line voltage Shunt release Power supply Consumption Operational voltage Breaking time Us V CDW7-2000~6300 CDW7-1000 V AC380 36VA 5VA (0.7~1.1)Us less than 30ms AC220 24VA 5VA DC220 24W 5W DC110 24W 5W

Closing voltage release Closing release shall close the circuit breaker when supply voltage drops to a value ranging between 85% to 110% Closing voltage release Power supply Consumption Operational voltage Breaking time Us V CDW7-2000~6300 CDW7-1000 V AC380 36VA 10VA (0.85~1.1)Us less than 70ms AC220 24VA 10VA DC220 24W 10W DC110 24W 10W

71

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Electric motor Motor operator shall complete energy storage when line voltage rise to between 85% to110% Motor operator structure Rated control power supply volage Us V CDW7Power consumption CDW7-1000 Operational voltage V Energy storage time In2000A 3200AIn6300A 2000~6300 2000AIn3200A AC380 85VA 110VA 150VA 80VA (0.85~1.1)Us less than 5s AC220 85VA 110VA 150VA 80VA DC220 85VA 110VA 150VA 80VA DC110 85VA 110VA 150VA 80VA

Auxiliary switch Making and breaking capacity of auxiliary contact under normal or abnormal conditions Utilizaiton category Auxiliary contact default type Conventional thermal current Ith Auxiliary contact's energized operational performance Making& breaking capacity Under normal conditions Under abnormal I/Ie making I/Iebreaking U/Ue cosor T0.95 I/Ie U/Ue operation cycles
note:* when Pe50WT0.95es upper limit300ms

Low-voltage Distribution

AC-15 6A

DC-13

Four normal open four normal close Equal to circuit breaker operation performance 10 1 1 0.3 10 1.1 0.3 10 1 1 1 6Pe 1.1 1.1 6Pe 10

conditions cosor T0.95

72

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Overall Dimension
Unit:mm CDW7-1000A fixed circuit breaker overall and mounting dimension horizonal/vertical connection diagram

Low-voltage

Distribution

CDW7-1000A fixed circuit breaker outline and horizonal/vertical connected dimension Current rating (A) Pole L L1 L2 200, 400 3P 266 244 630 266 244 800, 1000 266 244 200, 400 4P 336 314 70 630 336 314 70 800, 1000 336 314 70

N 6 12 12 8 16 16

73

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

CDW7-1000A drawout circuit breaker overall and horizonal/vertical connection diagram

Low-voltage Distribution

CDW7-1000A drawout type circuit breaker outline and horizonal/vertical wiring Current rating (A) 200, 400 630 800, 1000 200, 400 630 800, 1000 Pole 3P L 284 284 284 354 354 354 L1 194 194 194 264 264 264 L2 70 70 70 L3 55 75 75 55 75 75 L4 63 83 83 63 83 83 N 6 12 12 8 16 16 H 6 8 10 6 8 10

4P

74

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical connection dimension(CDW7-2000)

Low-voltage

Distribution

CDW7-2000A fixed circuit breaker vertical connection diagram

CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical wiring Type CDW7-2000 Pole 3P 4P CDW7-3200 3P 4P L1 362 457 457 422 537 L2 318 413 413 378 493 L3 292 292 292 352 352 L4 340 435 435 400 515 In A 400~800 1000~1600 2000 2000~2500 3200 a 10 15 20 20 30

note:* CDW7-2000 mounting dimension is same regardless of different current used in"horizonalwiring" or"vertical-wiring"

75

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

door

Low-voltage Distribution

76

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

CDW7-2000A~6300A drawout type circuit breaker outline and horizonal/vertical connection Type Pole CDW7-2000 1) 3P 4P 3P 4P 3P 4P 3P L1 375 375 470 435 550 813 928 928 L2 335 335 430 395 510 773 888 888 L3 292 292 292 352 352 352 352 352 L4 265 265 360 325 440 703 818 818 L5 247 247 247 307 307 307 307 307 W1 461 461 461 471 471 494 494 494 W2 507 507 507 517 517 540 540 540 b 179 179 179 189 189 212 212 212 In A 400~800 1000~1600 2000 2000~2500 3200~4000 4000 5000~6300 5000~6300 a 10 15 20 20 30 20 30 30

CDW7-3200 CDW7-6300 (4000/5000A) CDW7-6300

note: 1) CDW7-2000 the mounting dimension is same regardless of different current used in"horizonal-connected" or "vertical-connected"

CDW7-1000 panel cut-out dimension

Low-voltage

Distribution

CDW7-1000A fixed type

CDW7-1000A drawout type

CDW7-2000~6300 panel cut-out dimension

CDW7-2000~6300A fixed type

CDW7-2000~6300A drawout type

CDW7-2000~6300 panel cut-out dimension and mounting dimension Type CDW7-2000 CDW7-3200 CDW7-6300 a 306 366 366 b 346 406 406 c 3P 0 0 189(4000/5000A) 246.5(6300A) 4P 47.5 57.5 246.5(4000/5000A) --

77

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Auxiliary connection diagramn

ECWS-H type intelligent release unit connection diagram

Low-voltage Distribution

1:QFX with different current ratings shall connect with different sources. 2:If users have special requirementsthe auxiliary switches can reach up to a maximum of 6ON6OFF. At this condition, the 45 - 49 output terminals will become the auxiliary switch contacts. For the detailed wiring diagram , please see the dotted line part of the diagram. At this time, the external sensor and supplementary functions are not available.

Sign interpretation in connection diagram:

----Connected by user ----Connected by manufacturer SB1 shunt pushbutton(self-prepared) SB2 close pushbutton SB3 undervoltage pushbutton(self-prepared) X closing voltage release FU fuse F closing voltage release DF auxiliary switch SA electrical path switch M electric motor Q undervoltage instantaneous lamp(self-prepared) (or time-delay) release XT

circuit breaker wiring terminal

4142 when controller power choose DC,the output is DC24V,user can select DC power module 4344 circuit breaker status detection terminal(used when MCR function included) 45 overload pre-alarm signal output 46 automatic diagnosis alarm signal output 47 fault trip alarm signal output 48 earthing but non-tripping,only alarm signal output 49 four groups of contacts output common terminal 5051 externally sensor input terminal 58 able to directly connect to power supply(automatic pre-energization),also able to join up with normal open pushbutton to connect to power supply(manual preenergization)

78

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

ECW-M intelligent release connection diragram

Low-voltage

Distribution

Pin functions: Pin 1# and 2#: Auxiliary power input,pin 1# is positive for DC input Pin 3#, 4#, 5#: Fault trip contact output (4# is common terminal); contact capacity: AC380V, 16A Pin 6# and 7#, 8# and 9#: Two groups of auxiliary contacts for breaker status; contact capacity: AC380V, 16A 12#,13#(Contact1)and 14#,15#(Contact2)and 16#,17#(Contact3)and 18#,19#(Contact4):Output of four groups of signal for controllers,contact capacity:4A/240V 7A/24VDC 20#: Earth protection 21#~24#:input of voltage signal (Note:the order cant be wrong) Components: Q - Under-voltage release F - Shunt release X Closing electromagnet DF - Auxiliary switch M - Motor SB1Button for closing SB2Button for shunt

Note: 1. If the control voltage values of Q, F, X, and M are different to each other, these components can be connected to different power supply units; in the application, the shunt release and closing electromagnet shall be connected serially with normally open and normally closed auxiliary contacts (the part enclosed by dotted lines shall be connected by the user; the part represented by a two-dot chain line is the wiring of circuit 51); Note 2: The pin 35# can be connected to the power supply directly (automatic pre-energy storage) or connected serially to a normally open button and then to the power supply (manual pre-energy storage); Note 3: If the user requests, pin #6~#7 can be connected to normally closed contacts; Note 4: The ECW power supply module I is a DC power supply module, and it can be omitted if the power supply is AC power supply; the polarity and lead-ins/lead-outs shall not be reversed (for draw-out type circuit breakers, the lead-outs of the power supply module has been connected before the circuit break is shipped from the factory); Note 5: In case of circuit 47, the auxiliary contacts are four closed and four open contacts; pin #25 and #26 are input terminals of an external current transformer , used for earth fault protection as (3P+N)T type ; Note 6: In case of circuit 51, the auxiliary contacts are six closed and six open contacts (or five closed and five open contacts); pin #25, #26, and #51 form normally open and normally closed contacts; Note 7: If Profibus or any other protocol is used, ECW-H + DP conversion module and other conversion modules must be ordered; ECW power supply module lV and ECW201 relay module must be ordered separately; Note 8:Pin #12~#19 input/output contacts can be user-defined programmable signal contacts.

79

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

ECW-H intelligent release connection diagram

Low-voltage Distribution

1: different power supply can be connected respectively if the control supply voltage of QFXM are different the shunt releaseclosing release shall respectively,join up with normal opennormal close auxiliary contacts(the broken line part of diagram is connected by user own;double point line is 51 circuit connection)

2: terminal 35# can directly connect to power supply (automatic pre-energy storage),or join up with normal open pushbutton to connect power supply(manual pre-energy storage)

components: Q- undervoltage release F- shunt release X- closing voltage release DF- auxiliary switch M- electric motor

3: terminal 6#~7# can lead out normal close contact if user suggested 4: ECW power supply module is DC power supply module, the module doesn't exist when power supply current is AC,polarity,incoming line and leading-out line shall not connected reversely(leading-out terminal of power supply module in drawout type had been connected before sale)

5: in 47 circuit,auxiliary contact is 4 open 4 close;25#26# is input terminal of external sensor 6: in 51 circuit,auxiliary contact is 6open6close(5open 5close);25#26#51# form normal open normal close contact(earth-leakage protection excluded)

7: if using profibus or other protocols, user shall order ECWH+HP transformation module and others;ECW power supply moduleV,ECW201 relay module and others shall order seperately

Pin function: 1#2#: 1# is the front terminal when DC is supplied by auxiliary power 3#4#5#: fault trip contact output(4 is the common termincaoln)contact capacit: AC380V16A 6#7#8#9#: two groups of circuit breaker status auxiliary terminal: contact capacit:AC380V16A 10#11#: respectively as the communication leading-out of RS485A ,RS485B 12#: overload pre-alarm signal output 13#: communication remote control shunt release output 14#: communication remote control closing output or instantaneous short time-delay trip signal output 15#: communication remote control energy storage or long time-delay trip signal output 16#: S-earth(RS-485 transmissionn common ground wire 17#: load monitor output1 18#: load monitor signal 2 19#: signal output common earth wire 20#: PE line ,shield earth wire 21#: neutral voltage signal N phase 22#: voltage signal A phase 23#: voltage signal B phase 24#: voltage signal C phase

8: #12~#19 output input contacts are programmableselfdefined signal contaccts

80

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Other Additional Parameter

ECWS-H ECW-H overcurrent proteciton curver

Low-voltage

Distribution

ECW-M overcurrent protection curve

81

CDW7 Air Circuit Breaker


Standard: IEC 60947-2

Order Instruction
Customer Sets purchased Date

Mode CDW7

Fixed

Draw-out

3 Poles

4Poles

Rated voltage H Type Intelligent electronic trip Basic function

AC400

AC690

Rated current Short-circuit short delay time protection Load monitoring function (Not available for L type)

In= A Short-circuit instantaneous protection Metering function

Overload long delay time protection Earthing protection

Low-voltage Distribution

Power supply

AC 230V

AC 400V

DC 220V

DC 110V

Under-voltage instantaneous trip Under-voltage trip Under-voltage time-delay trip

AC 230V 1s 3s

AC 400V 5s

Shunt trip Accessaries Mechanical interlock Energy releasing electromagnet Motor Driven Interphase barrier N phase external connection

AC 230V AC 230V AC 230V Escutcheon

AC 400V AC 400V AC 400V

DC 220V DC 220V DC 220V

DC 110V DC 110V DC 110V

Earth-leakage CT(Only for cable)

Auxiliary switch Auxiliary Connection Terminal

standard(4a4b)

special(6a6b)

1-lock,1-key Steel-cable interlock Interlocking rod with 3 switches

2-lock,1-key Interlocking rod with 2 switches

3-lock, 2-key

Door interlock(Available for Draw-out type)

Note:for any special requirement,please contact with the manufacturer.

82

Contents
Motor Control & Protection

Contactor&Thermal Overload Relay


CDC17-K CDC17 CDR17 CJX2 JRS1D CJX2-F JRS2 Mini AC Contactor AC Contactor Thermal Overload Relay AC Contactor Thermal Overload Relay AC Contactor Thermal Overload Relay

86-127
86 89 100 106 112 117 123

Definite Purpose Contactor


CDC9 CDCK8 Switching Capacitor Contactor Air Condition Contactor

128-134
128 131

Relay
CDZ17 CDZ8 JSZ3 XJ9 Contactor Relay Miniature Relay Electronic Time Relay Phase Failure and Sequence Protection Relay

135-146
135 139 143 146

Motor Control & Protection

83

Motor Control and Protection Product Overview


Contactor
CDC17-K

Thermal Overload Relay


86
CDR17-18

100

Current:6-12A Pole:3P,4P Coil Voltage:AC24-400V

Setting Current:0.1-18A Trip class:10A

CDC17

89

CDR17

Current:9-185A Pole:3P Coil Voltage:AC24-400V

100

Setting Current:0.1-185A Trip class:10A, 10

CDC17
Motor Control & Protection

89

Current:115-1000A Pole:3P Coil Voltage:AC110-400V

JRS2

123

Setting Current:55-630A Trip class:10A,10

CJX2

106

JRS1D

Current:9-95A Pole:3P Coil Voltage:AC36-400V

112

Setting Current:0.1-93A Trip class:10A,10

CJX2-F

117

JRS2

123

Current:115-630A Pole:3P Coil Voltage:AC36-400V

Setting Current:55-630A Trip class:10A,10

84

Motor Control and Protection Product Overview


Definite Purpose Contactor
CDC9 Current: 25-65A Poles: 3P Application: Power factor correction Features: A unique limiting module Effectively inhibit the inrush current

128

CDCK8 Current: 25-45A Poles: 1P,2P

131

Application: Air Conditioner Features: Compact Convenient and reliable connection Suitable for high-temperature enviroment

Control Relay

Motor Control & Protection

CDZ8 Contact: 2Z,3Z,4Z Coil Voltage: AC6-220V DC6-220V

139

CDZ17 Contact: 13, 22, 31, 40, 04, 44, 53, 62, 71, 80 Coil Voltage: AC36-380V DC22-440V

135

Features: PCB type and plug-in type are availble Convenient installation High sensitivity Wide range of application

Features: Large capacity of contacts Scalable accessories Longer life

85

CDC17-K Mini AC Contactor


Standard: IEC 60947-4-1

Function

CDC17-K AC contactor provide: Remote make & break of circuits Frequent start and stop of motors

Order Information
Moter P(kW) 380V 2.2 Rated current(A) 6 Main contact NO 3 3 4 2 4 9 3 3 4 2 4 12 3 3
Motor Control & Protection

Auxiliary contact NO 1 0 0 0 1 0 0 0 1 0 0 NC 0 1 0 0 0 1 0 0 0 1 0

NC 0 0 0 2 0 0 0 2 0 0 0

Reference CDC17K63010* CDC17K63001* CDC17K64000* CDC17K62200* CDC17K93010* CDC17K93001* CDC17K94000* CDC17K92200* CDC17K123010* CDC17K123001* CDC17K124000*

4 Reference Description CDC17-K 6 30 10 *

Coil Frequency Coil Voltage Auxiliary contact Main contact Rate current Model

Coil voltage code coil voltage * 24V B 36V C 110V F 127V S 220V M 380V Q 400V V

Coil frequency code coil frequency 50Hz 5 60Hz 6

86

CDC17-K Mini AC Contactor


Standard: IEC 60947-4-1

Technical Data
Model Main circuit characteristics Rated operational current 380V/400V, AC-3 380V/400V, AC-4 660V/690V, AC-3 660V/690V, AC-4 Rated operational voltage Rated insulation voltage Rated conventional thermal current Pole Power of controlled 3-phase cage motor Electric durabilities Operating rate Electric durabilities Operating rate Mechanical durabilities Matched Fuse Cable connection Coil Coil voltage(Us) Operational voltage Drop-out voltage Inrush Sealed Auxliary contact Rated conventional thermal current Rated insulation voltage Rated operational current 380V, AC-15 220V, DC-13 Control capacity AC-15 DC-13 V A A A VA W 690 10 0.95 0.15 360 33 V V V VA VA AC 24,36,110,127,220,380,400 85%110% Us 20%75% Us 30 4.5 Inflexible cable number of piece Cross Section of Cable mm2 AC-4 220V/230V, AC-3 380V/400V, AC-3 660V/690V, AC-3 AC-3 kW kW kW 10 operations cycles/h 10 operations cycles/h 104 cycles
4 4

CDC17-K06 A A A A V V A 6 2.6 3.5 1.2 690 16 3, 4 1.5 2.2 3 100 1200 20 600 1000 RT16-16 2 4

CDC17-K09 9 3.5 5 1.5

CDC17-K12 12 5 6 2

220/230, 380/400, 660/690 20 2.2 4 5.5 3 4 7.5

Motor Control & Protection

RT16-20

87

CDC17-K Mini AC Contactor


Standard: IEC 60947-4-1

Working Conditions
Ambient temperature:-5+40, the daily average temperature 35 Altitude: 2000 m Humidity: Maximum temperature is +40, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures Pollution Level: 3 Installation Type: Installation position: should be installed in the absence of a significant shake and shock and vibration place

Install Location

Motor Control & Protection

Overall Dimensions

88

CDC17 AC Contactor
Standard: IEC 60947-4-1

Order Information
Moter P(kW) 380V 4 Rate current (A) 9 Auxiliary contact NO 1 0 5.5 12 1 0 7.5 18 1 0 11 25 1 0 15 32 1 0 18.5 22 30 37 45 55 75 90 110 132 160 220 265 335 450 560 40 50 65 80 95 115 150 185 225 265 330 400 500 630 800 1000 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 NC 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 Reference CDC17910 CDC17901 CDC171210 CDC171201 CDC171810 CDC171801 CDC172510 CDC172501 CDC173210 CDC173201 CDC174011 CDC175011 CDC176511 CDC178011 CDC179511 CDC1711522 CDC1715022 CDC1718522 CDC1722522 CDC1726522 CDC1733022 CDC1740022 CDC1750022 CDC1763022 CDC1780022 CDC17100022
Motor Control & Protection

Reference Description CDC17 9 10 * Coil Frequency Coil Voltage Auxiliary contact Rate current Model

Coil voltage code coil voltage 24V B 36V C 110V F 127V S 220V M 380V Q 400V V

Coil frequency code coil frequency 50Hz 5 60Hz 6

89

CDC17 AC Contactor
Standard: IEC 60947-4-1

Technical Data
Model Main circuit characteristics Rated operational current 380V / 400V, AC-3 A 380V / 400V, AC-4 A 660V, AC-3 660V, AC-4 Rated operational voltage Rated insulation voltage Rated conventional thermal current Power of controlled 3-phase cage motor Electric durabilities Operating rate Electric durabilities Operating rate Mechanical durabilities Coil Coil voltage(Us) Operational voltage Drop-out voltage Inrush Sealed Heat dissipation Accessories Auxiliary contact Time-delay block Mechanical Interlock Matched Relay Matched Fuse Cross Section of Cable Number of Piece Flexible cable Inflexible cable Weight mm mm Kg
2 2

CDC17-9 9 3.5 6.6 1.5 380 / 400 690 20 4 5.5 1200 300 1000

CDC17-12 12 5 8.9 2 660 20 5.5 7.5

CDC17-18 18 7.7 12 3.8

CDC17-25 25 8.5 18 4.4

CDC17-32 32 12 21 7.5

A A V V A kW kW cycles/h

32 7.5 9

40 11 15

50 15 18.5 80

380V/400V, AC-3 660V, AC-3 AC-3 AC-4

104 operations 100 10 operations 20


4

cycles/h 10 cycles V V V VA VA W Front mount Side mount Front mount


4

800

Motor Control & Protection

AC 24, 36, 48, 110, 127, 220, 230, 380, 400 85%~110%Us 20%~75%Us 70 8 1.8~2.7 CDF4 CDLA2 or CDLA3 CDJL17-1 CDR17-18 RT16-20 1 2.5 4 0.315 2 1 2 RT16-32 1 4 6 0.335 0.513 2 CDR17-32 RT16-40 1 2 RT16-50 1 6 10 0.510 2 110 11 3~4

90

CDC17 AC Contactor
Standard: IEC 60947-4-1

Technical Data
Model Main circuit characteristics Rated operational current 380V / 400V, AC-3 A 380V / 400V, AC-4 A 660V, AC-3 660V, AC-4 Rated operational voltage Rated insulation voltage Rated conventional thermal current Power of controlled 3-phase cage motor Electric durabilities Operating rate Electric durabilities Operating rate Mechanical durabilities Coil Coil voltage(Us) Operational voltage Drop-out voltage Inrush Sealed Heat dissipation Accessories Auxiliary contact Time-delay block Mechanical Interlock Matched Relay Matched Fuse Cross Section of Cable Number of Piece Flexible cable Inflexible cable Weight mm mm Kg
2 2

CDC17-40 40 18.5 34 9 380 / 400 690 60 18.5 30 1200 300 800

CDC17-50 50 24 39 12 660 80 22 33

CDC17-65 65 28 42 14

CDC17-80 80 37 49 17.3

CDC17-95 95 44 55 21.3

A A V V A kW kW cycles/h

80 30 37

125 37 45 60

125 45 45

380V/400V, AC-3 660V, AC-3 AC-3 AC-4

104 operations 80 10 operations 20


4

cycles/h 10 cycles V V V VA VA W Front mount Side mount Front mount


4

600
Motor Control & Protection

AC 24, 36, 48, 110, 127, 220, 230, 380, 400 85%~110%Us 20%~75%Us 200 20 6~10 CDF4 CDLA2 or CDLA3 CDJL17-2 CDR17-95 RT16-63 1 10 16 1.14 2 RT16-80 1 16 25 2 RT16-100 1 25 25 2 RT16-125 1 50 50 1.35 2 25 RT16-200 1 50 50 2 25 -

91

CDC17 AC Contactor
Standard: IEC 60947-4-1

Technical Data
Model Main circuit characteristics Rated operational current 380V/400V, AC-3 A 380V/400V, AC-4 A 660V, AC-3 660V, AC-4 Rated operational voltage Rated insulation voltage Rated conventional thermal current Power of controlled 3-phase cage motor Electric durabilities Operating rate Electric durabilities Operating rate Mechanical durabilities Coil Coil voltage(Us) Operational voltage Drop-out voltage Inrush Sealed Heat dissipation Accessories Auxiliary contact Time-delay block Mechanical Interlock Matched Relay Matched Fuse Cross Section of Cable Number of Piece Flexible cable Inflexible cable Weight mm2 mm2 Kg Front mount Side mount Front mount CDFC17-11,CDFC17-12 CDJL17-3 CDR17-185 RT16-200 1 95 2.15 2 50 1 120 2 25x3 RT16-250 1 150 2 JRS2-400 RT16-250 1 185 2 RT16-400 1 240 6.6 2 1 240 6.6 2 30x5 V V V VA VA W AC110,127,220,230,380,400 85%~110%Us 20%~75%Us 559 33 9.5~14 695 45 13~15 1198 83 18~25
Motor Control & Protection

CDC17-115 CDC17-150 CDC17-185 CDC17-225 CDC17-265 CDC17-330 115 52 86 49 380 / 400 690 150 55 80
4

150 60 110 61 660 150 75 100

185 79 118 69

225 85 135 82

265 105 170 98

330 117 225 118

A A V V A kW cycles/h

210 90 110

225 110 129

300 132 160 300 30

330 160 220

380V/400V, AC-3 kW 660V, AC-3 AC-3 AC-4

10 operations 60 1200 300 600 600 10 operations 20


4

cycles/h 10 cycles
4

20x3 -

25x3 -

32x4 -

32x4 -

92

CDC17 AC Contactor
Standard: IEC 60947-4-1

Technical Data
Model Main circuit characteristics Rated operational current 380V / 400V, AC-3 A 380V / 400V, AC-4 A 660V, AC-3 660V, AC-4 Rated operational voltage Rated insulation voltage Rated conventional thermal current Power of controlled 3-phase cage motor Electric durabilities Operating rate Electric durabilities Operating rate Mechanical durabilities Coil Coil voltage(Us) Operational voltage Drop-out voltage Inrush Sealed Heat dissipation Accessories Auxiliary contact Time-delay block Mechanical Interlock Matched Relay Matched Fuse Cross Section of Cable Number of Piece Flexible cable Inflexible cable Weight mm2 mm Kg
2

CDC17-400 400 138 305 135 380 / 400 690 500 220 280
4

CDC17-500 500 147 355 145 660 500 265 335

CDC17-630 630 188 460 170

CDC17-800 800 242 530 215

CDC17-1000 1000 580 -

A A V V A kW kW cycles/h

800 335 450

800 450 500

1000 560 560

380V/400V, AC-3 660V, AC-3 AC-3 AC-4

10 operations 60 300 30 600 AC110,127,220,230,380,400 85%~110%Us 20%~75%Us 780 10 8~14 CDFC17-21 JRS2-400 RT16-500 2 150 30x5 9.36 185 40x5 240 50x5 22.8 60x5 80x5 JRS2-630 RT16-630 RT16-800 RT17-4/1000 RT17-4/-1250 1050 12 10~18 600
Motor Control & Protection

10 operations 20 cycles/h 10 cycles V V V VA VA W


4

Front mount Side mount Front mount

93

CDC17 AC Contactor
Standard: IEC 60947-4-1

CDC17-995 Contactor Accessories


Top of auxiliary contact

Mechanical interlocking module

Air delay head

Motor Control & Protection

Thermal overload relays

Contactor
9 Top of auxiliary contact 12 18 25 32 40 50 65 80 95

2 Poles:CDF411,CDF402,CDF420 4 Poles:CDF404,CDF413,CDF422,CDF431,CDF440 Making time-delay:CDLA2DT0,CDLA2DT2,CDLA2DT4 Breaking time-delay:CDLA3DT0,CDLA3DT2,CDLA3DT4

Air delay head Mechanical interlocking module

CDJL171,CDJL17265,CDJL17295

CDR17-18 Thermal 0.1-0.13-0.15A overload relays 14-16-18

CDR17-32 4.5-5-6.3A 23-25-32

CDR17-95 9-10-12A 75-80-95A

94

CDC17 AC Contactor
Standard: IEC 60947-4-1

CDC17-115~1000 Contactor Accessories


Top of auxiliary contact

Mechanical interlocking module Side auxiliary contact

Air delay head Thermal overload relays

Contactor
115 150 185 225 265 330 400 500 630 800 1000

Motor Control & Protection

Top of auxiliary contact

2 Poles:CDF411,CDF402,CDF420 4 Poles:CDF404,CDF413,CDF422,CDF431,CDF440 Only applicable for CDC17-115~330

Air delay head

Making time-delay:CDLA2DT0,CDLA2DT2,CDLA2DT4 Breaking time-delay:CDLA3DT0,CDLA3DT2,CDLA3DT4 Only applicable for CDC17-115~330

Side auxiliary contact

CDFC1711,CDFC1721,CDFC1712 Only applicable for CDC17-115~500

Mechanical interlocking module

CDJL173150,CDJL173225,CDJL173330 Only applicable for CDC17-115~330

JRS2-180 Thermal 55-88A overload relays 150-180A

JRS2-400 80-125A 250-400A

JRS2-630 320-500A 400-630A

Only applicable for CDC17-115~630

95

CDC17 AC Contactor
Standard: IEC 60947-4-1

Accessories
CDF4 Top of auxiliary contact
Pole Contact NO 1 2P 0 2 CDF402 CDC17 115~330 NC 1 Wiring diagram Reference Recommended Contactor CDC17 115~330

CDF411

CDF420

CDC17 115~330

CDF404

CDC17 115~330

1 4P
Motor Control & Protection

CDF413

CDC17 115~330

CDF422

CDC17 115~330

CDF431

CDC17 115~330

CDF440

CDC17 115~330

CDLA Air delay head


Delay Type Making time-delay Wiring diagram Delay Range 0.1-3S 0.1-30S 10-180S Breaking time-delay 0.1-3S 0.1-30S 10-180S Reference CDLA2ON0 CDLA2ON2 CDLA2ON4 CDLA3OFF0 CDLA3OFF2 CDLA3OFF4 Recommended Contactor CDC17 115~330 CDC17 115~330 CDC17 115~330 CDC17 115~330 CDC17 115~330 CDC17 115~330

CDFC17 Side auxiliary contact


Pole 2P Contact NO 1 NC 1
13 23 31

Wiring diagram

Reference CDFC1711

Recommended Contactor CDC17 115~330

3P

1
14 24 32

CDFC1721

CDC17 115~330

CDFC1712

CDC17 115~330

96

CDC17 AC Contactor
Standard: IEC 60947-4-1

Accessories
Mechanical interlocking module
Contactor Specifications CDC17-9~32A CDC17-40~65A CDC17-80~95A CDC17-115~150A CDC17-185~225A CDC17-265~330A Reference CDJL171 CDJL17265 CDJL17295 CDJL173150 CDJL173225 CDJL173330

Working Conditions
Ambient temperature:-5+40, the daily average temperature 35 Altitude: 2000 m Humidity: Maximum temperature is +40, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures Pollution Level: 3 Installation Type: Installation position: should be installed in the absence of a significant shake and shock and vibration place

Motor Control & Protection

Install Location

97

CDC17 AC Contactor
Standard: IEC 60947-4-1

Overall Dimensions
CDC17-9~32 a 2- d

CDC17-40~95 3 d

Motor Control & Protection

Type CDC17-9~12 CDC17-18 CDC17-25 CDC17-32

Amax Bmax Cmax C1max C2max a 45 45 56.5 56.5 68 68 79 79 127 127 77 82 91 95 115 123 109 115 124 127 145 153 133 138 149 152 170 178 400.21 400.21 350.21

b 590.28 660.43 1050.57

c 4.5 4.5 6.5

CDC17-40~65 75 CDC17-80~95 85

Note:C1max-Contactor+CDF4

C2max-Contactor+CDLA

98

CDC17 AC Contactor
Standard: IEC 60947-4-1

CDC17-115~150

CDC17-185~330

Type CDC17-185 CDC17-225

A 138 138

A1 111 111 144

B 180 199 207

C 163 163 201

C1 95 95 119

a1 40 48 48

a2 20 25 25

a3 80 80 96

b1 158 172 180

b2 154 172 180

9 11 11

b3 150 150 166

1 7 7 11

Motor Control & Protection

CDC17-265, 330 171 CDC17-400~500


48 48

CDC17-630~1000

99

CDR17 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Function

CDR17 series thermal overload relay provide: Protection of circuits and motors against overload Protection of circuits and motors against phase loss Motor starters installation in association with contactors

Order Information
Reference Description CDR17 18 P15 Setting current Rated current Model

Type

Rated insulation voltage Ui V

Frame size rated current 18

Range of current setting A 0.1~0.13~0.15 0.12~0.16~0.18 0.18~0.2~0.25 0.25~0.32~0.36 0.35~0.4~0.5 0.5~0.6~0.7 0.63~0.72~0.9 0.9~1~1.2 1.2~1.6~1.8 1.8~2~2.5 2.5~3.2~3.6 3.5~4~4.8 4.5~5~6.3 5~6~7 6.3~7.2~9 9~10~12 11~13~15 14~16~18

Reference CDR1718P15 CDR1718P18 CDR1718P25 CDR1718P36 CDR1718P5 CDR1718P7 CDR1718P9 CDR17181P2 CDR17181P8 CDR17182P5 CDR17183P6 CDR17184P8 CDR17186P3 CDR17187 CDR17189 CDR171812 CDR171815 CDR171818 CDR17326P3 CDR17327 CDR17329 CDR173212 CDR173218 CDR173225 CDR173232

Recommended contactor CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-9~18 CDC17-25~32 CDC17-25~32 CDC17-25~32 CDC17-25~32 CDC17-25~32 CDC17-25~32 CDC17-25~32

CDR17-18 690
Motor Control & Protection

CDR17-32 690

32

4.5~5~6.3 5~6~7 6.3~7.2~9 9~10~12 12~16~18 18~20~25 23~25~32

100

CDR17 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Order Information
Rated insulation voltage Ui V Recommended contactor CDC17-40~95 CDC17-40~95 CDC17-40~95 CDC17-40~95 CDC17-40~95 CDC17-40~95 CDC17-40~95 CDC17-40~95 CDC17-40~95 CDC17-40~95 CDC17-115~185 CDC17-115~185 CDC17-115~185 CDC17-115~185 CDC17-115~185 CDC17-115~185 CDC17-115~185 CDC17-115~185 CDC17-185 CDC17-185
Motor Control & Protection

Type

Frame size rated current 95

Range of current setting A 9~10~12 12~16~18 18~20~25 23~25~32 30~36~40 37~45~50 48~55~65 55~63~70 63~70~80 75~90~95

Reference CDR179512 CDR179518 CDR179525 CDR179532 CDR179540 CDR179550 CDR179565 CDR179570 CDR179580 CDR179595 CDR1718550 CDR1718565 CDR1718570 CDR1718580 CDR1718595 CDR17185115 CDR17185135 CDR17185150 CDR17185160 CDR17185185

CDR17-95 690

CDR17-185 690

185

37~45~50 48~55~65 55~63~70 63~70~80 75~90~95 90~100~115 105~115~135 120~135~150 130~150~160 150~160~185

101

CDR17 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Technical Data
Temperature compensation Trip class 10A 10 Rated insulation voltage Ui V Structure characteristics Overload protection Phase-failure protection Manual reset Automatic reset Stop button Test button Trip direction Tolerance on slope in any direction Control circuit Utilization category
Motor Control & Protection

-10~+55 CDR17-18, 32, 95 CDR17-185 690V

Yes Yes Yes Yes Yes Yes Yes 22.5

AC-15 50 690 220/230 1.64/1.57 6 50 690 50 690

DC-13

Rated frequency Hz Rated insulation voltage Ui V Rated operational voltage Ue V Rated operational current Ie A Conventional free air thermal current Ith A Contact circuit Utilization category Rated frequency Hz Rated insulation voltage Ui V Rated operational voltage Ue V Rated operational current Ie A Conventional free air thermal current Ith A

690 220/230 0.23/0.22 6

380/400 660/690 0.95/0.9 0.55/0.52 6 6

AC-15 50 690 660/690 6 6

DC-13

690 220/230 6 6

102

CDR17 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Trip Characteristic
Multiples of Sequence setting current Trip time Trip class 10A Trip class 10 Initial condition Ambient temperature

Limits of operation of relays when energized on all poles 1 1.05 >2h >2h From cold state From hot state(immediately following sequence 1 test) From hot state(immediately following sequence 1 test) From cold state +20 +20

1.2

<2h

<2h

1.5

2min

4min

7.2

2sTp10s

4sTp10s

Limits of operation when energized on two poles


Any two The thirdpoles pole
Motor Control & Protection

1.0

0.9

>2h

>2h

From cold state From hot state(immediately following sequence 1 test)

+20

1.15

<2h

<2h

Accessories
Name CDR17-18 CDR17-32 CDR17-95 Reference CDR1718J CDR1732J CDR1795J

103

CDR17 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Work conditions
Ambient temperature: -10~+55, daily average temperature 35 Altitude: 2000m Humidity: The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +40. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20. Special measures should be taken against condensation occuring on product surface caused by temperature change Pollution class: 3

Installation conditions
Installation Type: Installation position: Unobvious shake and impact shock is necessary. Vertically mounting. Tolerance on slope in any direction shall not exceed 22.5
22.5

22.5

Motor Control & Protection

360

Wire Connection Picture


FU-Fuse KM-Contactor FR-Relay SB1-Stop Button SB2-Start Button

104

CDR17 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Overall Dimensions

CDR17-18

CDR17-32

Motor Control & Protection

CDR17-95

CDR17-185

105

CJX2 AC Contactor
Standard: IEC 60947-4-1

Function

CJX2 AC contactors provide: Remote make & break of circuits Frequent start and stop of motors

Order Information
Auxiliary contact NO 1 0 7.5 12 1 0 10 18 1 0 15 25 1 0 18.5
Motor Control & Protection

Motor P(kW) 380V 5.5

Rated current(A) 9

NC 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1

Reference CJX2910* CJX2901* CJX21210* CJX21201* CJX21810* CJX21801* CJX22510* CJX22501* CJX23210* CJX23201* CJX24011* CJX25011* CJX26511* CJX28011* CJX29511*

32

1 0

30 33 37 45 55 Reference Description CJX2 9 10 *

40 50 65 80 95

1 1 1 1 1

Coil Frequency Coil Voltage Auxiliary contact Rate current Model

Coil voltage code coil voltage * 36V C 110V F 127V S 220V M 380V Q 400V V

Coil frequency code coil frequency 50Hz 5 60Hz 6

106

CJX2 AC Contactor
Standard: IEC 60947-4-1

Technical Data
Model Main circuit characteristics Rated operational voltage Rated insulation voltage Conventional thermal current Rated operational current V V A 380, 660 690 25 9 3.5 6.6 1.5 4 5.5 2.2 25 12 5 8.9 2 5.5 7.5 3 32 18 7.7 12 3.8 7.5 10 4 40 25 18 8.5 4.4 11 15 5.5 50 32 21 12 7.5 15 18.5 7.5 80 20 800 600 300 1.5 2.5 4 6 60 40 34 18.5 9 18.5 30 11 80 15 800 600 300 10 16 16 80 50 39 24 12 22 33 15 80 65 42 28 14 30 37 18.5 125 80 49 37 17.3 37 45 22 60 10 600 600 300
Motor Control & Protection

CJX2-09 CJX2-12 CJX2-18 CJX2-25 CJX2-32 CJX2-40 CJX2-50 CJX2-65 CJX2-80 CJX2-95

125 95 55 44 21.3 45 55 25

380V, AC-3 A 380V, AC-4 A 660V, AC-3 A 660V, AC-4 A

Power of controlled 220V, AC-3 kW 3-phase cage motor Electric durabilities Mechanical durabilities Operating rate Matched Fuse Cable connection cross section Coil Coil voltage(Us) Operational voltage Drop-out voltage Inrush Sealed Heat dissipation Accessories Auxiliary contact Time-delay block Mechanical Interlock Rated conventional thermal current Rated operational voltage AC DC Rated control capacity A V V Front mount Side mount Front mount V V V VA VA W mm2 380V, AC-3 kW 660V, AC-4 kW

4 AC-3 10 operations 100 4 AC-4 10 operations 20

104 cycles AC-3 cycles/h AC-4 cycles/h

1000 1200 300 1.5

RT16-20 RT16-20 RT16-32 RT16-40 RT16-50 RT16-63 RT16-80 RT16-80 RT16-100 RT16-125 25 35

AC36,110,127,220,380,400 85%~110%Us 20%~75%Us 70 8 1.8~2.7 F4 FC6 SK4 FR632H 10 380 220 360 33 FR695HX 110 11 3~4 200 20 6~10

AC-15 VA DC-13 W

107

CJX2 AC Contactor
Standard: IEC 60947-4-1

CJX2 Contactor Accessories

Mechanical interlocking module

Top of auxiliary contact Side auxiliary contact Air delay head

Thermal overload relays


Motor Control & Protection

Contactor
9 Top of auxiliary contact 12 18 25 32 40 50 65 80 95

2 Poles:F411,F402,F420 4 Poles: F404,F413,F422,F431,F440

Side auxiliary contact

2 Poles: FC611, FC602, FC620

Air delay head

Making time-delay: SK420,SK422,SK424 Breaking time-delay: SK430,SK432,SK434

Mechanical interlocking module

9-32A: FR632H 40-95A: FR695HX

Thermal overload relays

JRS1D-25 0.1-0.16A ... 17-25A

JRS1D-36 23-32A 30-40A

JRS1D-93 23-32A ... 80-93A

108

CJX2 AC Contactor
Standard: IEC 60947-4-1

Accessories
F4 Top of auxiliary contact
Pole Contact NO 1 2P 0 2 0 1 4P 2 3 4 NC 1 2 0 4 3 2 1 0 Wiring diagram Reference

F411 F402 F420 F404 F413 F422 F431


Motor Control & Protection

F440

SK4 Air delay head


Delay Type Making timedelay Wiring diagram Delay Range 0.1-3S 0.1-30S 10-180S 0.1-3S Breaking time-delay 0.1-30S 10-180S Reference SK420 SK422 SK424 SK430 SK432 SK434

FC6 Side auxiliary contact


Pole Contact NO 0 NC 2
52 53 62 61

Wiring diagram
51 61

Reference FC602

2P

1
54 53 62 63

FC611

0
54 64

FC620

109

CJX2 AC Contactor
Standard: IEC 60947-4-1

Accessories
Mechanical interlocking module
Contactor Specifications CJX2-9~32 CJX2-40~95 Reference FR632H FR695HX

Working Conditions
Ambient temperature:-5+40, the daily average temperature 35 Altitude: 2000 m Humidity: Maximum temperature is +40, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures Pollution Level: 3 Installation Type: Installation position: should be installed in the absence of a significant shake and shock and vibration place

Motor Control & Protection

Install Location

110

CJX2 AC Contactor
Standard: IEC 60947-4-1

Overall Dimensions
CJX2-09~32

Unit:mm

CJX2-40~95

Motor Control & Protection

Product Type CJX2-09~12 CJX2-18 CJX2-25 CJX2-32 CJX2-40~65

Amax 47 47 57 57 77

Bmax 76 76 86 86 129

Cmax 82 87 97 102 116

C1max 115 120 130 135 149

C2max 115 120 130 135 149

a 35 40 40

b 50/60 50/60 100/110

d 4.5 4.5 6.5

CJX2-80~95 127 87 160 160 129 Note: C1max is auxiliary contact group +F4 C2max is air-delay contact+SK4

111

JRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Function

JRS1D relay provide:


Protect motor and circuit Possess overload and phase failure protection functions.

Order Information
Reference Description
JRS1D 25 P16

Setting current Rated current Model

Frame size rated current(A) 25

Current setting(A) 0.1~0.16 0.16~0.25 0.25~0.4

Reference JRS1D25P16 JRS1D25P25 JRS1D25P4 JRS1D25P63 JRS1D251 JRS1D251P6 JRS1D252P5 JRS1D254 JRS1D256 JRS1D258 JRS1D2510 JRS1D2513 JRS1D2518 JRS1D2525 JRS1D3632 JRS1D3640 JRS1D9332 JRS1D9340 JRS1D9350 JRS1D9365 JRS1D9370 JRS1D9380 JRS1D9393

Recommended contactor CJX2-09~32 CJX2-09~32 CJX2-09~32 CJX2-09~32 CJX2-09~32 CJX2-09~32 CJX2-09~32 CJX2-09~32 CJX2-09~32 CJX2-09~32 CJX2-09~32 CJX2-12~32 CJX2-18~32 CJX2-25~32 CJX2-25~32 CJX2-32 CJX2-40~95 CJX2-40~95 CJX2-50~95 CJX2-50~95 CJX2-65~95 CJX2-80~95 CJX2-95

Recommended fuse RT16-4 RT16-4 RT16-4 RT16-4 RT16-4 RT16-4 RT16-6 RT16-10 RT16-16 RT16-20 RT16-20 RT16-25 RT16-35 RT16-50 RT16-63 RT16-80 RT16-63 RT16-80 RT16-100 RT16-100 RT16-125 RT16-125 RT16-160

Motor Control & Protection

0.4~0.63 0.63~1 1~1.6 1.6~2.5 2.5~4 4~6 5.5~8 7~10 9~13 12~18 17~25 36 23~32 30~40 93 23~32 30~40 37~50 48~65 55~70 63~80 80~93

112

JRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Technical Data
Temperature compensation Trip class 10A 10 Rated insulation voltage Ui V Structure characteristics Overload protection Phase-failure protection Manual reset Automatic reset Stop button Test button Trip direction Tolerance on slope in any direction Auxiliary circuit Utilization category Rated frequency Hz Rated insulation voltage Ui V Rated operational voltage Ue V Rated operational current Ie A Conventional free air thermal current I th A NO NC AC-15 50 500 220 1.64 5 5 50 500 380 0.95 5 5 DC-13 50 500 220 0.15 5 5 Yes Yes Yes Yes Yes Yes Yes 5
Motor Control & Protection

-5~+40 JRS1D-25, 36 JRS1D-93 660V

113

JRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Accessories
Name JRS1D-25 JRS1D-36 JRS1D-93 Reference JRS1D25J JRS1D36J JRS1D93J

Trip Characteristic
Sequence Multiples of setting current Trip time Trip class Trip class 10 10A Initial condition Ambient temperature

Limits of operation of relays when energized on all poles 1


Motor Control & Protection

1.05

>2h

>2h

From cold state From hot state(immediately following sequence 1 test) From hot state(immediately following sequence 1 test) From cold state

+20

1.2

<2h

<2h

1.5

2min

4min

7.2

2s Tp10s

4sTp10s

+20

Limits of operation when energized on two poles


Any two The thirdpoles pole

1.0

0.9

>2h

>2h

From cold state From hot state(immediately following sequence 1 test)

+20

1.15

<2h

<2h

114

JRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Work Conditions
Ambient temperature: -5~+40, daily average temperature 35 Altitude: 2000m Humidity:The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +40. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20. Special measures should be taken against condensation occuring on product surface caused by temperature change Pollution class: 3

Installation Conditions

c Installation Type: Installation position: Unobvious shake and impact shock is necessary. Vertically mounting. c Tolerance on slope in any direction shall not exceed 5
5

360
Motor Control & Protection

Wire Connection Picture


FU-Fuse KM-Contactor FR-Relay SB1-Stop Button SB2-Start Button

115

JRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Overall Dimensions
Unit: mm JRS1D-25 / Z

JRS1D-36 / Z

Motor Control & Protection

JRS1D-93 / Z

116

CJX2-F AC Contactor
Standard: IEC 60947-4-1

Function

CJX2-F AC contactors provide: Remote make & break of circuits Frequent start and stop of motors

Order Information
Motor P(kW) 380V 55 75 90 110 132 160 200 250 335 Rated current (A) 115 150 185 225 265 330 400 500 630 Reference CJX2F115* CJX2F150* CJX2F185* CJX2F225* CJX2F265* CJX2F330* CJX2F400* CJX2F500* CJX2F630*

Reference Description
CJX2-F 9 10 * Coil Frequency Coil Voltage Auxiliary contact Rate current Model

Motor Control & Protection

Coil voltage code coil voltage * 36V C 110V F 220V M 380V Q 400V V

Coil frequency code coil frequency 50Hz 5 60Hz 6

117

CJX2-F AC Contactor
Standard: IEC 60947-4-1

Technical Data
Model Main circuit characteristics Rated operational voltage Rated insulation voltage Rated conventional thermal current Rated operational 380V, AC-3 current 380V, AC-4 660V, AC-3 660V, AC-4 Power of controlled 380V, AC-3 3-phase cage motor 380V, AC-4 660V, AC-3 660V, AC-4 Mechanical durabilities Electric durabilities Operating rate Matched Fuse Cable cooper number of Piece
2 connection conductor cross section mm

CJX2-F115 CJX2-F150 CJX2-F185 CJX2-F225 CJX2-F265 CJX2-F330 CJX2-F400 CJX2-F500 CJX2-F630 V V A A A A A kW kW kW kW 1000 380,660 200 115 52 86 49 55 25 80 45 200 150 60 108 61 75 30 100 55 1000 120 600 120 1 95 / / 275 185 79 118 69 90 40 110 63 600 100 600 120 1 150 / / 275 225 85 137 82 110 45 129 75 600 100 600 120 1 150 / / 315 265 105 170 98 132 55 160 90 600 80 600 120 1 185 / / 380 330 117 235 118 160 63 220 110 600 80 600 120 1 240 / / 450 400 138 303 135 200 72 280 129 600 80 300 120 2 150 2 305 630 500 147 353 145 250 80 335 140 600 80 300 120 2 185 2 405 800 630 188 462 170 335 100 450 160 600 80 300 120 2 240 2 505

104 cycles 1000 104 operations 120 AC-3 AC-4 cycles/h cycles/h 600 120 1 95 / /

RT16-250 RT16-355 RT16-425 RT16-500 RT16-630 RT16-800 RT16-800 RT17-1000 RT17-1250

Motor Control & Protection

cooper bar number of Piece dimension Coil Rated voltage power control(Us) V Operational voltage Drop-out voltage Inrush Sealed Heat dissipation Auxliary contact Rated conventional thermal current A Rated operational voltage Rated control capacity AC DC V V V V VA VA W

AC36,110,220,380,400 85%110%Us 20%75%Us 550 45 16 10 380 220 360 33 550 45 16 800 55 24 800 55 24 1200 13 12 1200 13 12 1200 20 14 1250 24 18 1650 22 20

AC-15 VA DC-13 W

118

CJX2-F AC Contactor
Standard: IEC 60947-4-1

CJX2-F Contactor Accessories

Top of auxiliary contact

Air delay head

Thermal overload relays

Motor Control & Protection

Contactor
115 Top of auxiliary contact 150 185 225 265 330 400 500 630

2 Poles:F411,F402,F420 4 Poles: F404,F413,F422,F431,F440

Air delay head

Making time-delay : SK420,SK422,SK424 Breaking time-delay : SK430,SK432,SK434

Thermal overload relays

JRS2-180 55-88A ... 150-180A

JRS2-400 80-125A ... 250-400A

JRS2-630 320-500A 400-630A

119

CJX2-F AC Contactor
Standard: IEC 60947-4-1

Accessories
F4 Top of auxiliary contact
Pole Contact NO 1 2P NC 1 Wiring diagram Reference

F411

F402

F420

F404

4P

F413

2
Motor Control & Protection

F422

F431

F440

SK4 Air delay head


Delay Type Wiring diagram Delay Range 0.1-3S 0.1-30S 10-180S Breaking time-delay 0.1-3S 0.1-30S 10-180S Reference SK420 SK422 SK424 SK430 SK432 SK434

Making timedelay

120

CJX2-F AC Contactor
Standard: IEC 60947-4-1

Working Conditions
Ambient temperature:-5+40, the daily average temperature 35 Altitude: 2000 m Humidity: Maximum temperature is +40, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures Pollution Level: 3 Installation Type: Installation position: should be installed in the absence of a significant shake and shock and vibration place

Install Location

Motor Control & Protection

121

CJX2-F AC Contactor
Standard: IEC 60947-4-1

Overall Dimensions
CJX2-F115~330 Unit: mm

CJX2-F400~500

Motor Control & Protection

CJX2-F630

Model

Amax Bmax Cmax P


163 171 174 197 203 206 206 238 304 172 172 183 183 215 220 220 233 256 37 40 40 48 48 48 48 55 80

S
20 20 20 25 25 25 25 30 40 M6 M8 M8 M10 M10 M10 M10 M10 M12

F
131 131 131 131 147 147 146 150 181

M
147 150 154 172 178 181 181 208 264

H
124 124 127 127 147 158 158 172 202

L
107 107

X1
10 10

X1
15 15 15 15 15 15 20 20 30

Ga Ha
80 80 80 80 96 96 80 80 110~1120 110~1120 110~1120 110~1120 110~1120 110~1120 170~1180 170~1180

(200~500v) (600~1000v)

CJX2-F115 167 CJX2-F150 167 CJX2-F185 171 CJX2-F225 171 CJX2-F265 202 CJX2-F330 213 CJX2-F400 213 CJX2-F500 233 CJX2-F630 309

103.5 10 103.5 10 141 145 145 146 155 10 10 15 15 20

180 170~1180

122

JRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Function

JRS2 relay provide:


Protect motor and circuit Possess overload and phase failure protection functions.

Order Information
Reference Description
JRS2 12P5 P16 F:Installed independently Setting current Rated current Model

Frame size rated current( A ) 180

Current setting(A) 55~88 63~90 80~110 90~120 110~135 120~150 135~160 150~180

Reference JRS218088F JRS218090F JRS2180110F JRS2180120F JRS2180135F JRS2180150F JRS2180160F JRS2180180F JRS2400125F JRS2400200F JRS2400250F JRS2400320F JRS2400400F JRS2630500F JRS2630630F

Recommended fuse RT16 -125 RT16 -125 RT16 -200 RT16 -200 RT16 -200 RT16 -200 RT16 -250 RT16 -250 RT16 -200 RT16 -400 RT16 -400 RT16 -500 RT16 -500 RT16 -630 RT16 -630

Motor Control & Protection

400

80~125 125~200 160~250 200~320 250~400

630

320~500 400~630

123

JRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Technical Data

Temperature compensation Trip class 10A 10 Rated insulation voltage Ui V Structure characteristics Overload protection Phase-failure protection Manual reset Automatic reset Stop button Test button Trip direction Tolerance on slope in any direction Auxiliary circuit Utilization category Rated frequency Hz Rated insulation voltage Ui V Rated operational voltage Ue V Rated operational current Ie A Conventional free NO NC
Motor Control & Protection

-5~+40 JRS2-180 JRS2-400, 630 660V

Yes Yes Yes Yes Yes Yes Yes 5

AC-15 50 380 220 1.64 5 5 50 380 380 0.95 5 5

DC-13 50 500 220 0.16 5 5

124

JRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Trip Characteristic
Trip time Initial condition Trip class Trip 10A class 10

Sequence

Multiples of setting current

Ambient temperature

Limits of operation of relays when energized on all poles 1 1.05 >2h >2h From cold state +20

1.2

<2h

<2h

From hot state(immediately following sequence 1 test)

1.5

2min

4min

From hot state(immediately following sequence 1 test)

7.2

2s Tp10s

4s Tp10s

From cold state

+20
Motor Control & Protection

Limits of operation when energized on two poles


Any two The thirdpoles pole

1 2

1.0 1.15

0.9 0

>2h <2h

>2h <2h

From cold state From hot state(immediately following sequence 1 test)

+20

125

JRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Work Conditions
Ambient temperature: -5~+40, daily average temperature 35 Altitude: 2000m Humidity: The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +40. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20. Special measures should be taken against condensation occuring on product surface caused by temperature change Pollution class: 3

Installation Conditions
Installation Type: Installation position: Unobvious shake and impact shock is necessary. Vertically mounting. Tolerance on slope in any direction shall not exceed 5
5

360

Motor Control & Protection

Wire Connection Picture


FU-Fuse KM-Contactor FR-Relay SB1-Stop Button SB2-Start Button

126

JRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Overall Dimensions

Unit: mm

JRS2-180/F

Motor Control & Protection

JRS2-400~630/F

25x4 50 50 10.5

70

171

146

127

CDC9 Switching Capacitor Contactor


Standard: IEC 60947-4-1 IEC 60947-5-1

Function

CDC9 switching capacitor contactors provide:


Switch three-phase unipolar or multipolar capacitor group,to improve their power factor Reduce the current closing of the impact of capacitor

Order Information
Auxiliary contact NO 1 2 0 32 1 2 0 43
Motor Control & Protection

Rated current(A) 25

NC 1 0 2 1 0 2 1 0 2 2 1 2 1

Reference CDC92511* CDC92520* CDC92502* CDC93211* CDC93220* CDC93202* CDC94311* CDC94320* CDC94302* CDC96312* CDC96321* CDC99512* CDC99521*

1 2 0

63

1 2

95

1 2

Reference Description CDC9 9 10 * Coil Frequency Coil Voltage Auxiliary contact Rate current Model Coil voltage code coil voltage * 36V C Coil frequency code coil frequency 50Hz 5 60Hz 6 110V F 127V S 220V M 380V Q 400V V

128

CDC9 Switching Capacitor Contactor


Standard: IEC 60947-4-1 IEC 60947-5-1

Technical Data
Model Main circuit Rated operational voltage Rated insulation voltage Controlled capacitor rate capacity 380V, AC-6b Controlled capacitor rate capacity 220V, AC-6b 380V, AC-6b Rate conventional thermal current Control inrush current capacity Mechanical life Electric life Operating frequency Cable connection cross section of copper conductor Coil Coil voltage(Us) Operational voltage Drop-out voltage Auxiliary contact Rate conventional thermal current Minimum load can be connected A 10 6V10mA V V V AC36,110,127,220,380,400
Motor Control & Protection

CDC9-25 V V A Kvar Kvar A 10 operations 380V, AC-6b 380V, AC-6b 10 operations operations/h mm2
4 4

CDC9-32

CDC9-43

CDC9-63

CDC9-95 400

380 500 17 6 12 25 20ln 100 10 300 4 23 9 18 32 29 10 20 43 43 15 30 63

63 22.5 45 95

120

85%~110%Us 20%~75%Us

129

CDC9 Switching Capacitor Contactor


Standard: IEC 60947-4-1 IEC 60947-5-1

Working Conditions
Ambient temperature:-5+40, the daily average temperature 35 2000 m Humidity: Maximum temperature is +40, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures Pollution Level: 3 Installation Type: Installation position: should be installed in the absence of a significant shake and shock and vibration place
Altitude:

Install Location

Motor Control & Protection

130

CDCK8 Air Condition Contactor


Standard: IEC 60947-4-1 IEC 60947-5-1

Function

CDCK8 air condition contactor provide: Remote make & break of circuits Frequent start and stop of motors

Order Information
Auxiliary contact NO 0 0 32 D(1P) 0 0 45 25 32 D(1P) S(2P) S(2P) 0 0 0 NC 1 0 1 0 0 0 0

Rated current(A) 25

Pole D(1P)

Reference CDCK825101* CDCK825100* CDCK832101* CDCK832100* CDCK845100* CDCK825200* CDCK832200*

Motor Control & Protection

Reference Description CDCK8 25 1 10 * Coil Frequency Coil Voltage Auxiliary contact Pole Rate current Model

Coil voltage code Coil voltage * 36V C 110V F 220V M

Coil frequency code Coil frequency 50Hz 5 60Hz 6

131

CDCK8 Air Condition Contactor


Standard: IEC 60947-4-1 IEC 60947-5-1

Technical Data
Model Main circuit characteristics Rate insulation voltage Rated voltage shock tolerance Rated operational voltage Rate conventional thermal current Rate operational current Power of controlled single-phase motor Mechanical life Electric life Operating frequency Short time withstand current Matched fuse Connecting line Coil Coil voltage(Us) Operational voltage Drop-out voltage Inrush Sealed Auxiliary contact Rate conventional thermal current Rated operational voltage V Control capability AC-1 A V VA 5 220 100 mm2 V V V VA VA
Motor Control & Protection

CDCK8-25D V kV V A AC-8b 220V, AC-8b A kW(Hp) x104 operations AC-8b AC-8b 10S x10 operations operations/h A
4

CDCK8-25S

CDCK8-32D

CDCK8-32S

CDCK8-45D

690 4 220 32 25 2.5(3) 100 8 300 8le RT16-40 6 AC36,110,220 70%~110%Us 20%~60%Us 36 4 RT16-50 10 RT16-63 16 40 32 3.2(4) 50 45 4.5(5)

132

CDCK8 Air Condition Contactor


Standard: IEC 60947-4-1 IEC 60947-5-1

Working Conditions
Ambient temperature:-5+40, the daily average temperature 35 Altitude: 2000 m Humidity: Maximum temperature is +40, air relative humidity of not more than 50%, at a lower temperature allows a higher relative humidity. For example, 20, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures Pollution Level: 3 Installation Type: Installation position: should be installed in the absence of a significant shake and shock and vibration place

Install Location

Motor Control & Protection

133

CDCK8 Air Condition Contactor


Standard: IEC 60947-4-1 IEC 60947-5-1

Overall Dimensions
Unit:mm

Product type CDCK8-25D,32D CDCK8-25D/01,32D/01 CDCK8-25S,32S CDCK8-45D


Motor Control & Protection

Amax 70 70 86 85

Bmax 62 69 61.5 67

134

CDZ17 Contactor Relay


Standard: IEC 60947-5-1

Function

CDZ17 contactor relays provide: Remote make & break of circuits Start, stop and control of small capacity motors Boost signals, interlock electric, transfer signals or control various kinds of magnetic coils

Order Information
Rated current(A)
6

Contact blocks
NO 1 2 3 4 0 NC 3 2 1 0 4 3 2 1 0 4 4 3 2 1 0 4 3 2 1 0

Reference
CDZ17613* CDZ17622* CDZ17631* CDZ17640* CDZ17604* CDZ17913* CDZ17922* CDZ17931* CDZ17940* CDZ17904*
Motor Control & Protection

1 2 3 4 0

4 5 6 7 8

CDZ17644* CDZ17653* CDZ17662* CDZ17671* CDZ17680* CDZ17944* CDZ17953* CDZ17962* CDZ17971* CDZ17980*

4 5 6 7 8

Coil voltage code Coil voltage * Coil power supply Coil power supply DC Z AC Default 24V B 36V C 48V E 110V F 220V M 380V Q 400V V 440V X

Reference Description
CDZ17 9 13 M Default: AC Z:DC Coil voltage Contact blocks Rated current Model
135

CDZ17 Contactor Relay


Standard: IEC 60947-5-1

Technical Data
Model Rated operational voltage V Rated operational voltage A Rated operational current V Rated operational current A Contact assemble AC-15 DC-13

6A
24 4 36 6 NO 1 2 3 4 0 48 2.5 110 6 110 1 6 NC 3 2 1 0 4 220 0.5 4 440 0.2 1.5

9A
24 6 36 9 NO 4 5 6 7 8 48 3.5 110 9 110 1.5 9 NC 4 3 2 1 0 220 0.6 6 440 0.3 690 3

220/230 380/400 690

220/230 380/400

Single

Double

Rated insulation voltage V Rated impulse withstand voltage V Rated conventional thermal current A Minimum load can be connected Electric durabilities(x10 operations) Mechanical durabilities(x104 cycles) Operating rate(cycles/h) Matched Fuse Cross Section of Cable mm2 (maximum) Coil Coil voltage(Us) V Operational voltage V Drop-out voltage V Inrush VA Sealed VA Heat dissipation W Weight Kg
4

690 8000 16 12V 100 1000 3000(AC) 1200(DC) 10mA

Motor Control & Protection

RT16-20
2.5(X2) AC36, 110, 220, 380,400; DC24, 48, 110, 220, 440 80%110%Us 20%75%Us(AC) 70(AC) 8(AC) 2.8(AC) 6.5(DC) 0.36(double,AC) 0.56(double,DC) 0.32(Single,AC) 0.52(Single,DC) 7(DC) 10%75%Us(DC)

136

CDZ17 Contactor Relay


Standard: IEC 60947-5-1

Work Conditions
Ambient Altitude:

temperature: -15~+50, daily average temperature 35 2000m Humidity: The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +50. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20. Special measures should be taken against condensation occuring on product surface caused by temperature change Pollution class: 3

Installation Conditions
Installation Installation

Type: position: Unobvious shake and impact shock is necessary. Vertically mounting. Tolerance on slope in any direction shall not exceed 5

25

25
Motor Control & Protection

137

CDZ17 Contactor Relay


Standard: IEC 60947-5-1

Overall Dimensions
CDZ17-40, 31, 22, 13, 04 Unit: mm

CDZ17-80, 71, 62, 53, 44

Motor Control & Protection

CDZ17-40/Z, 31/Z, 22/Z, 13/Z, 04/Z

CDZ17-80/Z,71/Z,62/Z,53/Z,44/Z

138

CDZ8 Miniature Relay

Function

Used to implement the conversion of intermediate control signals and low-power output, In the field of industrial control, used in conjunction with contactors, relays, circuit breakers, etc.

Order Information
Poles 2 Rated Current 5A LED L None L None Accessory 3 5A L None L None Accessroy 4 3A L None L None Accessory Rated voltage code Rated voltage * 6V I 12V J 24V B 36V C 48V E 110V F 127V S 220V M 230V N AC AC DC DC AC AC DC DC Voltage Type AC AC DC DC Reference CDZ8052L*1 CDZ8052*1 CDZ8052L*Z1 CDZ8052*Z1 CDZ8PYF08AXXKH CDZ8053L*1 CDZ8053*1 CDZ8053L*Z1 CDZ8053*Z1 CDZ8PYF11AXXKH CDZ8034L*1 CDZ8034*1 CDZ8034L*Z1 CDZ8034*Z1 CDZ8PYF14AXXKH
Motor Control & Protection

139

CDZ8 Miniature Relay

Technical Data
Form Capacity Nominal coil voltage Contact 2Z 5A AC 6-220V DC 6-220V Resistance Materials Electrical life expectancy Mechanical life expectancy Type Description Operating voltage (25) Release voltage (25) Maximum voltage (25) Coil consumption DC(W) AC(VA) Operating time (Rated voltage) Release time (Rated voltage) Dielectric Strength Between contacts Between contacts(different pole) Between Contact and coil Ambient temperature Humidity Atmospheric pressure Shock resistance Vibration resistance Install model Weight Coil Specifications (25) Rated voltage V.DC Coil resistance(10%) Rated voltage V.AC Coil resistance (10%) 6 40 6 11.5 12 160 12 40 24 600 24 160 36 36 370 48 48 600 110 110 3750 220 42000 127 4100 220 14000 1440 2600 11000 1800VAC/1min -25+55 35%85%RH 86106KPa 10G(Sine half-wave pulse11ms) 1055Hz Double amplitude:1.0mm Plug-in terminals 35g
Motor Control & Protection

3Z 5A

4Z 3A

50m Silver Alloy 105 times (1800 Ops/h) 107 times (18000 Ops/h) LED DC: 75%Ue, AC:80%Ue DC:10%Ue, AC:30%Ue 110%Ue 0.9 1.2 20ms 20ms 1300VAC/1min 1500VAC/1min

140

CDZ8 Miniature Relay

Accessories
Matched relay socket Outline dimensions(mm) 2Z CDZ8PYF08AXXKH Mount dimensions Wiring diagram

3Z

CDZ8PYF11AXXKH
Motor Control & Protection

4Z

CDZ8PYF14AXXKH

141

CDZ8 Miniature Relay

Overall Dimensions
Unit: mm

CDZ8-2Z

CDZ8-3Z

Motor Control & Protection

CDZ8-4Z

142

JSZ3 Series Electronic Time Relay


Standard: IEC 60947-5-1

Function

JSZ3 Series eletroms time relay provide Rated AC frequency 50Hz & controlling voltage 400V or below. Rated DC control power voltage 220V or below. Be used as time-control component in the automatic controlling circuit, according to the scheduled time turn on or off the circuit.

Order Information
Relay mode Relay after power-on Rated working voltage 120V Relay time A: 0.05-0.5s/5s/30s/3M B: 0.1-1s/10s/60s/6M C: 0.5-5s/50s/5M/30M D: 1-10s/100s/10M/60M E: 6s-60s/10M/60M/6h F: 0.2M-2M/20M/2h/12h G: 0.4M-4M/40M/4h/24h 240V A: 0.05-0.5s/5s/30s/3M B: 0.1-1s/10s/60s/6M C: 0.5-5s/50s/5M/30M D: 1-10s/100s/10M/60M E: 6s-60s/10M/60M/6h F: 0.2M-2M/20M/2h/12h G: 0.4M-4M/40M/4h/24h 400V A: 0.05-0.5s/5s/30s/3M B: 0.1-1s/10s/60s/6M C: 0.5-5s/50s/5M/30M D: 1-10s/100s/10M/60M E: 6s-60s/10M/60M/6h F: 0.2M-2M/20M/2h/12h G: 0.4M-4M/40M/4h/24h Reference JSZ3AA120 JSZ3AB120 JSZ3AC120 JSZ3AD120 JSZ3AE120 JSZ3AF120 JSZ3AG120 JSZ3AA240 JSZ3AB240 JSZ3AC240 JSZ3AD240 JSZ3AE240 JSZ3AF240 JSZ3AG240 JSZ3AA400 JSZ3AB400 JSZ3AC400 JSZ3AD400 JSZ3AE400 JSZ3AF400 JSZ3AG400
Motor Control & Protection

143

JSZ3 Series Electronic Time Relay


Standard: IEC 60947-5-1

Order Information
Relay mode Relay after power-off Rated working voltage 120V Relay time 1S: 0.1-1s 2S: 0.2-2s 3S: 0.3s-3s 5S: 0.5s-5s 6S: 0.6s-6s 10S: 1s-10s 20S: 2s-20s 30S: 3s-30s 60S: 6s-60s 100S: 10s-100s 180S: 18s-180s 4M: 0.4min-4min 5M: 0.5min-5min 6M: 0.6min-6min 10M: 1min-10min 20M: 2min-20min 30M: 3min-30min 1S: 0.1-1s 2S: 0.2-2s 3S: 0.3s-3s 5S: 0.5s-5s 6S: 0.6s-6s 10S: 1s-10s 20S: 2s-20s 30S: 3s-30s 60S: 6s-60s 100S: 10s-100s 180S: 18s-180s 4M: 0.4min-4min 5M: 0.5min-5min 6M: 0.6min-6min 10M: 1min-10min 20M: 2min-20min 30M: 3min-30min 1S: 0.1-1s 2S: 0.2-2s 3S: 0.3s-3s 5S: 0.5s-5s 6S: 0.6s-6s 10S: 1s-10s 20S: 2s-20s 30S: 3s-30s 60S: 6s-60s 100S: 10s-100s 180S: 18s-180s 4M: 0.4min-4min 5M: 0.5min-5min 6M: 0.6min-6min 10M: 1min-10min 20M: 2min-20min 30M: 3min-30min Reference JSZ3F1S120 JSZ3F2S120 JSZ3F3S120 JSZ3F5S120 JSZ3F6S120 JSZ3F10S120 JSZ3F20S120 JSZ3F30S120 JSZ3F60S120 JSZ3F100S120 JSZ3F180S120 JSZ3F4M120 JSZ3F5M120 JSZ3F6M120 JSZ3F10M120 JSZ3F20M120 JSZ3F30M120 JSZ3F1S240 JSZ3F2S240 JSZ3F3S240 JSZ3F5S240 JSZ3F6S240 JSZ3F10S240 JSZ3F20S240 JSZ3F30S240 JSZ3F60S240 JSZ3F100S240 JSZ3F180S240 JSZ3F4M240 JSZ3F5M240 JSZ3F6M240 JSZ3F10M240 JSZ3F20M240 JSZ3F30M240 JSZ3F1S400 JSZ3F2S400 JSZ3F3S400 JSZ3F5S400 JSZ3F6S400 JSZ3F10S400 JSZ3F20S400 JSZ3F30S400 JSZ3F60S400 JSZ3F100S400 JSZ3F180S400 JSZ3F4M400 JSZ3F5M400 JSZ3F6M400 JSZ3F10M400 JSZ3F20M400 JSZ3F30M400

240V
Motor Control & Protection

400V

144

JSZ3 Series Electronic Time Relay


Standard: IEC 60947-5-1

Technical Data
Condition AC-15 DC-13 Repetitive error Rated themal current Mechanical life Electric life Power loss Working mode Reset mode Contactor endurance Relay time 400V/1.95A; 240V/1.5A; 120V/3.0A 250V/0.27A; 125V/0.55A 5% 5A 1106 times 1105 times 3W A: Relay after power-on A:Power-off reset A:5A (Resistive) F:Relay after power-off F:External device reset F:1AResistive

JSZ3A: 0.05s-0.5s/5s/30s/3M,0.1s-1s/10s/60s/6M 0.5s-5s/50s/5M/30M,1s-10s/100s/10M/60M 6s-60s/10M/60M/6h,0.2M-2M/20M/2h/12h 0.4M-4M/40M/4h/24h JSZ3F: 0.1s-1s,0.2s-2s,0.3s-3s,0.5s-5s,0.6s-6s,1s10s,2s-20s,3s-30s,6s-60s,10s-100s,10s-120s,10s180s,0.4M-4M,0.5M-5M,0.6M-6M,1M-10M,2M20M,3M-30M


Motor Control & Protection

Temp. Install mode

-5+40 Install mounted, Din rail mounted, Panel mounted

Overall Dimensions
Unit: mm

ELECTRIC

145

XJ9 Phase Failure And Sequence Protection Relay


Standard: IEC 60947-5-1

Function

XJ9 phace failare and sequence proctection relay provide: Rated AC frequency of 50Hz, rated control supply voltage AC 400V. Phase failure and phase sequence protector.

Order Information
Function Phase failure sequency protection Voltage 380V 400V Reference XJ9380 XJ9400

Technical Data
Standard Overvoltage protection Undervoltage protection Phase failure & phase Wrong protect time Contactor mode Contactor endurance Power voltage Mechanical lifetime Electrical lifetime Power loss Contactor capacity
Motor Control & Protection

IEC 60947-5-1 400-480V(adjustable), Reaction time: 1.5-4S(adjustable) 320-400V(adjustabe). Reaction time: 2-9S(adjustable) Reaction time 2S 1 NO,1NC 5A Resistive AC 400V 1106 times 1105 times 1W AC400V3

Overall Dimensions
Unit: mm

XJ9

35.5

83Max

91Max 24Max

146

Contents
Power Energy Management

Current Transformer
LMK Series Current Transformer

148-150
148

Meter
DDS607 DTS607 DSS607 72 Series 96 Series Single-phase Electronic Watt-hour Meter Three-phase Four-Wire Electronic Watt-hour Meter Three-phase Three-Wire Electronic Watt-hour Meter Panel Meter Panel Meter

151-163
152 154 157 160 162

Digital Time Switch


KG316T KG316TD Digital Time Switch Digital Time Switch

164-167 1~5
165 166 167

KG816 Series Digital Time Switch

Voltage Stabilizer
TND SJW SBW Single-phase Full Automatic AC Voltage Stabilizer Three-phase Full Automatic AC Voltage Stabilizer Three-phase Compensation AC Voltage Stabilizer

168-174
169 171 173
Management Power Energy

147

LMK Series Current Transformer


Standard: IEC 60044-1

Function

LMK Series Current Transformer provide: Measuring and transforming the high current to low current.

Order Information
Model LMK-0.66-20 Current ratio (A) 30/5 50/5 75/5 100/5 100/5 150/5 200/5 100/5 200/5 250/5 300/5 250/5 300/5 400/5 500/5 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5 Rated Load (VA) 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75 Bar (mm) Diameter (mm) 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 35 35 35 35 35 35 35 45 45 45 45 45 45 45 50 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

Class: 0.5 Maximum Voltage: 0.66KV


Number of Turns Reference through the core

LMK-0.66-30

LMK-0.66-40

LMK-0.66-50

LMK-0.66-60

LMK-0.66-80

LMK-0.66-100

LMK-0.66-120

3010 3010 3010 4010 4010 4010 4010 5010 5010 5010 5010 5010 5010 5010 6020 6020 6020 6020 6020 6020 6020 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 12010 or 8030 12010 or 8030 12010 or 8030 12010 or 8030 12010 or 8030 12010 or 8030

5 3 2 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

LMKP63020 LMKP65020 LMKP67520 LMKP610020 LMKP610020 LMKP615020 LMKP620020 LMKP610030 LMKP620030 LMKP625030 LMKP630030 LMKP625040 LMKP630040 LMKP640040 LMKP650040 LMKP630050 LMKP640050 LMKP650050 LMKP660050 LMKP675050 LMKP680050 LMKP6100050 LMKP650060 LMKP660060 LMKP675060 LMKP680060 LMKP6100060 LMKP6120060 LMKP6150060 LMKP660080 LMKP675080 LMKP680080 LMKP6100080 LMKP6120080 LMKP6150080 LMKP6200080 LMKP6250080 LMKP6600100 LMKP6750100 LMKP6800100 LMKP61000100 LMKP61200100 LMKP61500100 LMKP62000100 LMKP62500100 LMKP63000100 LMKP61500120 LMKP62000120 LMKP62500120 LMKP63000120 LMKP64000120 LMKP65000120

Power Energy Management

148

LMK Series Current Transformer


Standard: IEC 60044-1

Order Information
Class: 1 Maximum Voltage: 0.66KV Model LMK-0.66-20 Current ratio Rated Load (VA) (A) 30/5 50/5 75/5 100/5 150/5 200/5 100/5 200/5 250/5 300/5 250/5 300/5 400/5 500/5 600/5 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 1200/5 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75 Bar (mm) Diameter Number of Turns Reference through the core (mm) 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 35 35 35 35 35 35 35 35 45 45 45 45 45 45 45 45 50 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 5 3 2 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LMKP6P13020 LMKP6P15020 LMKP6P17520 LMKP6P110020 LMKP6P115020 LMKP6P120020 LMKP6P110030 LMKP6P120030 LMKP6P125030 LMKP6P130030 LMKP6P125040 LMKP6P130040 LMKP6P140040 LMKP6P150040 LMKP6P160040 LMKP6P130050 LMKP6P140050 LMKP6P150050 LMKP6P160050 LMKP6P175050 LMKP6P180050 LMKP6P1100050 LMKP6P1120050 LMKP6P150060 LMKP6P160060 LMKP6P175060 LMKP6P180060 LMKP6P1100060 LMKP6P1120060 LMKP6P1150060 LMKP6P1200060 LMKP6P160080 LMKP6P175080 LMKP6P180080 LMKP6P1100080 LMKP6P1120080 LMKP6P1150080 LMKP6P1200080 LMKP6P1250080 LMKP6P1600100 LMKP6P1750100 LMKP6P1800100 LMKP6P11000100 LMKP6P11200100 LMKP6P11500100 LMKP6P12000100 LMKP6P12500100 LMKP6P13000100 LMKP6P11500120 LMKP6P12000120 LMKP6P12500120 LMKP6P13000120 LMKP6P14000120 LMKP6P15000120

LMK-0.66-30

LMK-0.66-40

LMK-0.66-50

LMK-0.66-60

LMK-0.66-80

LMK-0.66-100

LMK-0.66-120

3010 3010 3010 4010 4010 4010 4010 4010 5010 5010 5010 5010 5010 5010 5010 6020 6020 6020 6020 6020 6020 6020 6020 6020 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 8010 or 6030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 10010 or 8030 12010 or 8030 12010 or 8030 12010 or 8030 12010 or 8030 12010 or 8030 12010 or 8030

Management Power Energy

149

LMK Series Current Transformer


Standard: IEC 60044-1

Technical Data
Primary current: 100A-5000A Secondary approval: 5A, 1A Maximum voltage: 0.66kV Class: 0.5, 1.0, 3.0 Short time thermal current: Ith=100Ih Rated security coefficient: FS<5 Standard: IEC 60044-1

Overall Dimensions
Unit: mm

Power Energy Management

Model LMK-0.66-20 LMK-0.66-30 LMK-0.66-40 LMK-0.66-50 LMK-0.66-60 LMK-0.66-80 LMK-0.66-100 LMK-0.66-120

H 87 79 99 99 126 118 136 136

W 68 60 75 82 102 125 170 190

D 42 37 40 40 40 40 40 41

150

Meter Overview
Watt-hour Meter

Single-phase

Meter

DDS607 Type: Single-phase Specification 1.5(6)A, 3(6)A 2.5(10)A, 5(20)A 5(30)A, 10(40)A 15(60)A, 20(80)A 30(100)A

152

Three-phase
DTS607 Type: Three-phase Four-wire Specification 1.5(6)A, 3(6)A 2.5(10)A, 5(20)A 5(30)A, 10(40)A 15(60)A, 20(80)A 30(100)A

154

DSS607 Type: Three-phase Three-wire Specification 1.5(6)A, 3(6)A 5(20)A, 10(40)A 15(60)A. 20(80)A 30(100)A

157

Management Power Energy

Panel Meter

72 Series Type: Ammeter Voltmeter Frequency meter Specification 72x72mm

160

96 Series Type: Ammeter Voltmeter Frequency meter Specification 96x96mm

162

151

DDS607 Single-phase Electronic Watt-hour Meter


Standard:IEC 620531-21

Function

DDS607 single-phase watt-hour meter provide: Measuring the active energy in the single-phase AC power network with frequency of 50Hz or 60Hz. Measuring the active energy for enterprises, transformer substation or power substation. And be used as the automation meter in power transmission and distribution.

Order Informationn
Function Description Type A (Import chip) Type A (Import chip) Type A (Import chip) Type A (Import chip) Type A (Import chip) Type A (Import chip) Type A (Import chip) Type A (Import chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) LCD without 485 communications LCD without 485 communications LCD without 485 communications LCD without 485 communications LCD without 485 communications LCD without 485 communications LCD without 485 communications LCD with 485 communications LCD with 485 communications LCD with 485 communications LCD with 485 communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications
Note: Users need special specifications can be customized
Power Energy Management

Current specification 1.5(6)A 2.5(10)A 5(20)A 5(30)A 10(40)A 15(60)A 20(80)A 30(100)A 1.5(6)A 2.5(10)A 5(20)A 5(30)A 10(40)A 15(60)A 20(80)A 30(100)A 1.5(6)A 2.5(10)A 5(20)A 5(30)A 10(40)A 15(60)A 20(80)A 1.5(6)A 5(20)A 10(40)A 15(60)A 1.5(6)A 2.5(10)A 5(20)A 5(30)A 10(40)A 15(60)A 20(80)A 30(100)A

Reference DDS607N16M4A DDS607N110M4A DDS607N120M4A DDS607N130M6A DDS607N140M4A DDS607N160M4A DDS607N180M4A DDS607N1100M3A DDS607N26M4C DDS607N210M4C DDS607N220M4C DDS607N230M6C DDS607N240M4C DDS607N260M4C DDS607N280M4C DDS607N2100M3C DDS607N16M4CD DDS607N110M4CD DDS607N120M4CD DDS607N130M6CD DDS607N140M4CD DDS607N160M4CD DDS607N180M4CD DDS607N16M4CD485 DDS607N120M4CD485 DDS607N140M4CD485 DDS607N160M4CD485 DDS607N116M4CD485I DDS607N110M4CD485I DDS607N120M4CD485I DDS607N130M6CD485I DDS607N140M4CD485I DDS607N160M4CD485I DDS607N180M4CD485I DDS607N1100M3CD485I

152

DDS607 Single-phase Electronic Watt-hour Meter


Standard:IEC 620531-21

Technical Data
Standard Certificate Working voltage(V) Power loss Optional functions Normal working temp. Limited working temp. IEC 620531-21 KEMA 230V Voltage circuit 2W per10VA, Current circuit 4VA LCD display, Infrared communication, 485 communication -10~+45 -25~+55

Normal working voltage 0.9~1.1(Ref. voltage) Limited working voltage 0.8~1.15(Ref. voltage) Relative humidity Installation location 75% Should be installed in the height of 1.8m vertically and the angularity1

Overall Dimensions

Unit: mm

Management Power Energy

Single-phase Type A,C Meter

Single-phase LCD Meter

153

DTS607 Three-phase Four-wire Electronic Watt-hour Meter


Standard: IEC 62053-21

Function

DTS607 Three Phase four-wire watt-hour meter provide: Measuring the active energy in the three-phase four-wire AC power network at frequency of 50Hz or 60Hz. Measure the active energy of enterprises, transformer substation or power stations, and be used as automation meters of power transmission and distribution network.

Order Information
Voltage(V) 57.7/100 230/400 Grade 1 1 Current(A) 1.5(6) 3(6) 1.5(6) 3(6) 5(20) 10(40) 15(60) 20(80) 30(100) NOTE: M expresses the current multiple in the standard codes. Transformer function (H) is merely available for 1.5(6)A and 3(6)A. Reference DTS607WY16M4 DTS607WY16M2 DTS607NV16M4 DTS607NV16M2 DTS607NV120M4 DTS607NV120M5 DTS607NV120M6 DTS607NV120M7 DTS607NV120M8

Power Energy Management

154

DTS607 Three-phase Four-wire Electronic Watt-hour Meter


Standard: IEC 62053-21

Technical Data
Working voltage Power loss Optional functions Normal working temp. Ultimate working temp. Normal working voltage Relative humidity Installation location 57.7/100V, 230/400V Voltage circuit2W per10VA, Current circuit4VA LCD display, Infrared communication, 485 communication -10+45 -25+55 0.91.1(Ref. voltage) 75 Should be installed in the height of 1.8m vertically and the angularity1.

Ultimate working voltage 0.81.15(Ref. voltage)

Wiring Diagram

Management Power Energy

Wiring diagram for 3 x 57.7/100V 3 x 3(6)A with voltage transformer

Wiring diagram for 3 x 230/400V 3 x 3(6)A with current transformer

155

DTS607 Three-phase Four-wire Electronic Watt-hour Meter


Standard: IEC 62053-21

Wiring Diagram

Wiring diagram for 3 x 230/400V 3 x 2.5(10)A direct

pulse

pulse

pulse

pulse

Wiring diagram for impulse testing

Overall Dimensions

Unit: mm

Power Energy Management

156

DSS607 Single-phase Electronic Watt-hour Meter


Standard: IEC 62053-21

Function

DSS607 Single-phase electronic watt-hour meter provides: Measuring the active energy in the three-phase three-wire AC power network at frequency of 50Hz or 60Hz. Measure the active energy of enterprises, transformer substation or power stations, and be used as automation meters of power transmission and distribution network

Order Information
Voltage(V) 100 400 Grade 1 1 Current(A) 1.56 36 1.56 36 520 1040 1560 2080 30100 NOTE: M expresses the current multiple in the standard codes. Transformer function (H) is merely available for 1.5(6)A and 3(6)A. Reference DSS607Y16M4 DSS607Y16M2 DSS607V16M4 DSS607V16M2 DSS607V120M4 DSS607V140M4 DSS607V160M4 DSS607V180M4 DSS607V1100M3

Management Power Energy

157

DSS607 Single-phase Electronic Watt-hour Meter


Standard: IEC 62053-21

Technical Data

Standard

IEC 62053-21

75%

Wiring Diagram

Power Energy Management

Wiring diagram for 3 x 100V 3 x 3(6)A with voltage transformer

Wiring diagram for 3 x 400V 3 x 3(6)A with current transformer

158

DSS607 Single-phase Electronic Watt-hour Meter


Standard: IEC 62053-21

Wiring Diagram

Wiring diagram for 3 x 400V 3 x 2.5(10)A direct

pulse

pulse

pulse

pulse

Wiring diagram for impulse testing

Overall Dimensions
Unit: mm
Management Power Energy

159

72 Series Panel Meter


Standard: IEC 60051

Function

72 series panel meter provide: 72T applies to measure the current, voltage or frequency in the AC circuit. 72C applies to measure the current or voltage in the DC circuit. Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power supply cabinet, control cabinet and other electric-control facilities in the AC transmission circuit system

Order Information
Type Ammeter Accuracy Specification rating 1.5 30/5A 40/5A 50/5A 60/5A 75/5A 80/5A 100/5A 150/5A 160/5A 200/5A 250/5A 300/5A 400/5A 600/5A 800/5A 1000/5A 1600/5A 5000/5A 10000/5A 5A 2.5 15A 20A 25A 30A 40A 50A 60A 80A 100A 1.5 Voltmeter 1.5 5A 300V 500V 600V 500V Frequency meter 1.0 DC Type 45-55HZ (200V) AC Type DC Type AC Type AC Type Direct connection AC Type Direct connection 2 times of current overload 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 72TA15A 72TA20A 72TA25A 72TA30A 72TA40A 72TA50A 72TA60A 72TA80A 72TA100A 72CA5A 72TV300V 72TV500V 72TV600V 72CV5500V 72THZ01200V
Power Energy Management

Note AC Type transformer 2 times of current overload

Shape(mm) 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5 727267.5

Reference 72TA30 72TA40 72TA50 72TA60 72TA75 72TA80 72TA100 72TA150 72TA160 72TA200 72TA250 72TA300 72TA400 72TA600 72TA800 72TA1000 72TA1600 72TA5000 72TA10000 72TA5A

External connection 727267.5

160

72 Series Panel Meter


Standard: IEC 60051

Technical Data
Standard Dielectric strength test Impact test Response time Angular Deflection Temp. Humidity Environment : Installation: : IEC 60051 Frequency 50Hz /60Hz Voltage 2000V, duration 1 minute Max acceleration 147m/s 4s 90

-25~+40 (25%~80%)RH No mildew, insects, salt mist, dew in the air, few sands and dusts are permitted. Shall be installed Vertically v

Overall Dimensions

Management Power Energy

161

96 Series Panel Meter


Standard: IEC 60051

Function

96 series panel meter provide: 96T applies to measure the current, voltage or frequency in the AC circuit. 96C applies to measure the current or voltage in the DC circuit. Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power supply cabinet, control cabinet and other electric-control facilities in the AC transmission circuit system

Order Information
Type Ammeter Accuracy Specification rating 1.5 30/5A 40/5A 50/5A 60/5A 75/5A 80/5A 100/5A 150/5A 160/5A 200/5A 250/5A 300/5A 400/5A 600/5A 800/5A 1000/5A 1600/5A 5000/5A 10000/5A 5A 2.5 15A 20A 25A 30A 40A 50A 60A 80A 100A 1.5 Voltmeter 1.5 5A 300V 500V 600V 500V Frequency meter 1.0 DC Type 45-55HZ (200V) AC Type DC Type AC Type AC Type Direct connection AC Type Direct connection 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 96TA15A 96TA20A 96TA25A 96TA30A 96TA40A 96TA50A 96TA60A 96TA80A 96TA100A 96CA5A 96TV300V 96TV500V 96TV600V 96CV500 96THZ01200V
Power Energy Management

Note AC Type transformer

Shape(mm) 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5 969667.5

Reference 96TA30 96TA40 96TA50 96TA60 96TA75 96TA80 96TA100 96TA150 96TA160 96TA200 96TA250 96TA300 96TA400 96TA600 96TA800 96TA1000 96TA1600 96TA5000 96TA10000 96TA5A

External connection 969667.5

162

96 Series Panel Meter


Standard: IEC 60051

Technical Data
Standard Dielectric strength test IEC 60051 Frequency 50Hz /60Hz Voltage 2000V, duration 1 minute Impact test Response time Angular Deflection Temp. Humidity: Environment Installation: : Max acceleration 147m/s 4s 90

-25~+40 (25%~80%)RH No mildew, insects, salt mist, dew in the air, few sands and dusts are permitted. v Shall be installed Vertically

Overall Dimensions

Management Power Energy

163

Time Switch Overview

KG316T Max.switch times per day:10-on-10-off, 8-on-8-off Reset:Power-off reset

165

KG316TD Max.switch times per day:16-on-16-off Reset:key-button reset

166

KG816A Max.switch times per day:16-on-16-off Reset:key-button reset


Power Energy Management

167

KG816B Max.switch times per day:8-on-8-off Reset:key-button reset

167

164

KG316T Series Digital Time Switch


Standard: IEC 60947-5-1

Function

KG316T Series Digital Time Switch provide: Rated AC frequency of 50Hz, rated AC control voltage 400V or below. Be used as time control components in automatic control circuit, according to the scheduled time to turn-on or off the circuits.

Order Information
Output loops 10-on-10-off (Single output) 8-on-8-off (Double output) Rated control voltage AC:230V AC:400V AC:230V AC:400V Reference KG316T230 KG316T400 KG316T2230 KG316T2400

Technical Data
Standard Control time Using mode Control power Rated control voltage Rated thermal cur. Accuracy Mechanical life Electrical life Power loss Temp. Display modet Time-set Mode Battery Install Mode IEC 60947-5-1 Setting Value range from 1min to168h Operation by daily or weekly AC-15: 240V/3A 400V/1.9A 6kW 230/400V AC 10A y 2 1106 times 1105 times 3W -5+40 ~ Digital LED display Digital Keyswitch settingt Inner alkaline battery
Management Power Energy

Install mounted, Din rail mounted

Overall Dimensions
Unit: mm

Wiring Diagram

INPUT

OUT PUT

IN L1

OUT L1 OUT L2

SOURCE

LOAD

SOURCE

LOAD 1

LOAD 2

Single output

Double output

165

KG316TD Series Digital Time Switch


Standard: IEC 60947-5-1

Function

KG316TD Series Digital Time Switch provide: Rated AC frequency of 50Hz, rated control supply voltage AC 400V or below. Any circuit equipments that need to be turned-on-or-off timely.

Order Information
Output loops 16-on-16-off Rated control voltage AC:230V AC:400V Reference KG316TD230 KG316TD400

Technical Data
Standard Control time Using mode Control power Rated control voltage Rated thermal cu r. Accuracy Mechanical life Electrical life Power loss Temp. Display modet Time-set Mode Battery Install Mode
Power Energy Management

IEC 60947-5-1 Setting Value range from 1min to168h Operation by daily or weekly AC-15: 240V/3A 400V/1.9A 6kW 230/400V AC 10A 1106 times 1105 times 3W -5+40 Digital LED display Digital Keyswitch settingt Inner rechangeable battery Install mounted, Din rail mounted

Overall Dimensions
Unit: mm
Management Power Energy

Wiring Diagram

166

KG816 Series Digital Time Switch


Standard:IEC 60947-5-1

Function

KG816 Series Digital Time Switch provide: Rated AC frequency of 50Hz, rated AC control voltage 230V or below. Be used as time control components in automatic control circuit, according to the scheduled time to turn-on or off the circuits.

Order Information
Cover Non-transparent cover Transparent cover Output loops 16-on-16-off 8-on-8-off Rated control voltage AC:230V AC:230V Reference KG816A230 KG816B230

KG816A

Technical Data
Standard Control time IEC 60947-5-1 Setting value range from 1min to 168 hrs Operate by daily or weekly Using mode Countrol power Rated control voltage AC-15: 240V/3A; 400V/1.9A 6kW 230VAC 10A 2s/day 1X106 1X105 4.5W
Management Power Energy

KG816B

Rated thermal cur. Accuracy Mechanical life Electrical life Power loss Temp. Display mode Time-set Mode Battery Install Mode

-5~+40 Digital LED display Digital Keyswitch setting Inner rechangable battery Din rail mounted

Overall Dimensions
Unit: mm

87

87

45.5

36

66

167

Voltage Stabilizer Overview

Single-phase

TND Type: Single-phase

169

Specification: 0.5kVA, 1kVA 1.5kVA, 2kVA, 3kVA, 5kVA, 7kVA, 10kVA, 15kVA, 20kVA, 30kVA

Three-phase

SJW Type: Three-phase

171

Specification: 1.5kVA, 3kVA 4.5kVA, 6kVA, 9kVA, 15kVA, 20kVA, 30kVA, 45kVA, 60kVA

Power Energy Management

SBW

173

Type: Three-phase Compensation Specification: 10kVA, 15kVA 30kVA, 50kVA, 100kVA, 150kVA, 200kVA, 250kVA, 300kVA, 400kVA, 500kVA, 600kVA, 800kVA

168

TND Single-phase Full Automatic AC Voltage Stabilizer


Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1

Function

TND single-phase AC voltage stabilizer provide: This product is constructed by connecting three stabilizers with Y-connection Wide input voltage range, high efficiency, over-load protection, short adjusting time, high regulation accuracy, same input and output voltage waveform, small volume, less weight. It's available in the electric equipments and facilities in housing, school, shop, office and precision instrument for scientific experiment.

Order Information
Shape Output voltage 220V Power rating 0.5K 1K 1.5K 2K 3K 5K 7K 10K Cabinet 220V 10K 15K 20K 30K Desktop 230V 0.5K 1K 1.5K 2K 3K 5K 7K 10K Cabinet 230V 10K 15K 20K 30K

Reference Europe plug TNDP5HE220 TND1HE220 TND1P5HE220 TNDP5HE230 TND1HE230 TND1P5HE230 British plug TNDP5HB220 TND1HB220 TND1P5HB220 TNDP5HB230 TND1HB230 TND1P5HB230 Terminal connect TND2H220 TND3H220 TND5H220 TND7H220 TND10H220 TND10GH220 TND15GH220 TND20GH220 TND30GH220 TND2H230 TND3H230 TND5H230 TND7H230 TND10H230 TND10GH230 TND15GH230 TND20GH230 TND30GH230
Management Power Energy

Desktop

169

TND Single-phase Full Automatic AC Voltage Stabilizer

Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1

Technical Data
Type Output voltage Undervoltage protection Overvoltage protection Phase Input voltage range Efficiency Voltage regulation speed Frequency Enviroment temperature,relative temperature Rated maximum output current(A) Withstand voltage TND0.5kVA~5kVA Voltage regulation accuracy 2204%,1104% 246V4V single-phase 160V~240V >90% <1s(when input voltage change 10%) 50/60Hz -50~40 below 90% 2(500VA), 4(1000VA), 6(1500VA), 8(2000VA) 12(3000VA), 20(5000VA), 25(7000VA), 40(10KVA) 85(15KVA), 73(20KVA), 109(30KVA) 1500V/1min TND7kVA~30kVA 2204%

184V4V(set up according to the customers request)

Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1 Certification: CE

Overall Dimensions
Unit: mm

Power Energy Management

Product shape Desktop

Model TND-0.5 TND-1 TND-1.5 TND-2 TND-3 TND-5 TND-7 TND-10

WideLengthHight W 190 205 205 240 225 225 240 240 310 340 340 425 L 160 190 190 270 305 310 387 387 340 360 380 390 H 135 155 155 200 235 290 360 360 535 640 780 845

Cabinet type

TND-10 TND-15 TND-20 TND30

170

SJW Three-phase Full Automatic AC Voltage Stabilizer

Function

SJW three-phase AC voltage stabilizer provide: This product is constructed by connecting three stabilizers with Y-connection Wide input voltage range, high efficiency, over-load protection, short adjusting time, high regulation accuracy, same input and output voltage waveform, small volume, less weight. It's available in the electric equipments and facilities in housing, factory, shool, shop, office and precision instrument for scientific experiment.

Order Information
Shape Desktop Power rating 1.5 kVA 3 kVA 4.5 kVA Cabinet 6 kVA 9 kVA 15 kVA 20 kVA 30 kVA 45 kVA Reference SJW1P5 SJW3 SJW4P5 SJW6G SJW9G SJW15G SJW20G SJW30G SJW45G

Technical Data
Type Voltage regulation accuracy Output voltage Low-voltage protection Over-voltage protection Input voltage range Efficiency Voltage regulation speed Frequency Waveform distortion: Withstand voltage Temperature rise Environment temp. SJW 1.5KVA~60KVA 380V 4% 340V7V(adjustable) 420V 7V 280~415V 90% <1s(voltage fluctuation10%) 50/60Hz No additional distortion 1500V/1min <+60 -5~+40
Management Power Energy

Overall Dimensions

171

SJW Three-phase Full Automatic AC Voltage Stabilizer

Overall Dimensions
Cabinet

ELECTRIC

WORKING PHASE A

WORKING PHASE B

WORKING PHASE C

PROTECT

OUTPUT VOLTAGE

VOLTAGE TEST

SJW9 HIGH ACCURACY FULL-AUTOMATIC AC VOLTAGE STABILIZER

Shape

Model SJW-1P5 SJW-3 SJW-4.5 SJW-6 SJW-9 SJW-15 SJW-20 SJW-30 SJW-45 SJW-60

Wide x Length x Hight W 485 485 485 278 320 350 425 440 550 600 L 315 315 315 322 325 350 390 415 450 495 H 165 165 165 665 750 855 845 875 1170 1300

Desktop
Power Energy Management

Cabinet

172

SBW Three-phase Compensation AC Voltage Stabilizer

Function

SBW three-phase compensation AC voltage stabilizer provide: This product is designed and developed with the international advanced compensation technology. It can keep the output voltage in steady state automatically when the network voltage fluctuated or the load current varied. It's provided with over-voltage, over-current, phase sequence protection function.

Order Information
Power rating 10kVA 15kVA 30kVA 50kVA 100kVA 150kVA 200kVA 250kVA 300kVA 400kVA 500kVA 600kVA 800kVA Reference SBW10 SBW15 SBW30 SBW50 SBW100 SBW150 SBW200 SBW250 SBW300 SBW400 SBW500 SBW600 SBW800

Technical Data
Type Output voltage Voltage regulation accuracy Low-voltage protection Over-voltage protection Input voltage range Efficiency Voltage regulation speed Frequency Waveform distortion Insulation resistance Withstand voltage Temperature rise Environment temp. SBW 10KVA~1600KVA 380V 3% 340V 7V 425V 7V 304~456 V 98% <1s(voltage fluctuation10%) 50/60Hz 1% 2M 2000V/1min <+60 -5~+40

Management Power Energy

173

SBW Three-phase Compensation AC Voltage Stabilizer

Overall Dimensions
Unit: mm

Model SBW-10 SBW-20 SBW-50 SBW-100 SBW-200 SBW-500 SBW-800 SBW-1000 SBW-1600
Power Energy Management

Wide x Length x Hight W 750 750 800 850 1050 1400 1350 1050 1300 L 580 580 570 645 750 1100 1100 750 1100 H 1170 1170 1300 1460 1850 2100 2200 2200 2200

174

Contents
Industrial Control Components

Control Signal
LD11 LAY5 LAY7 LAY8 Indicator Light Pushbutton Switches Pushbutton Switches Pushbutton Switches

175-202
177 181 191 197

Accessories
RT16 RT18 Fuse Fuse

203-221
203 206 209 211 212 213 214 215 217 221

CCF CDPM CDP CDSM CDSF CDPS TB DINR

Series Cable Connector

Moving Industrial Plugs Fixed Industrial Plugs Moving Industrial Sockets Fixed Industrial Sockets Multi-function Plugs and Sockets

Series Copper Terminal Blocks

Din-rail

Industrial Control Components

175

Control Signal Overview

Indicator Light

LD11 IP degree:IP65 Specification

177

AC/DC: 6V 12V 24V 36V 48V 110V 230V AC: 230V 400V

Pushbutton Switches
LAY5 IP degree:IP55 Specification AC-15: 380V/2A 230V/3.3A DC-13: 230V/0.5A 110V/1.1A

181

LAY7 IP degree:IP55 Specification AC-15: 660V/1.1A 400V/2.0A 230V/3.3A DC-13: 440V/0.25A 230V/0.5A 110V/1A

191

LAY8 IP degree:IP55
Industrial Control Components

197

Specification AC-15: 660V/1.5A 400V/2.5A 230V/4.5A DC-13: 440V/0.2A 230V/0.4A 110V/0.8A

176

LD11 Indicator Light


Standard: IEC 60947-5

Function

LD11 Series of indicator light provide: Pilot signal, anticipating signals Emergency signals and other instructions incidents signal use

Technical Data
Rated voltage(V) Rated current(mA) Working life(H) Brightness of light(cd/m2) Power frequency withstand voltage Degree of protection AC/DC 6 12 24 36 48 110 230 50 30000 40 2500V AC 1min IP65 AC 230 400 20

Order Information
Installation dimension 22:22 Type Step-down Type Button colour Rated voltage AC.DC 6V Reference LD1122A21T7 LD1122A21T3 LD1122A21T4 LD1122A21T5 LD1122A21T8 LD1122A21J7 LD1122A21J3 LD1122A21J4 LD1122A21J5 LD1122A21J8 LD1122A21B7 LD1122A21B3 LD1122A21B4 LD1122A21B5 LD1122A21B8 LD1122A21F7 LD1122A21F3 LD1122A21F4 LD1122A21F5 LD1122A21F8 LD1122A21M7 LD1122A21M3 LD1122A21M4 LD1122A21M5 LD1122A21M8 LD1122A41M7 LD1122A41M3 LD1122A41M4 LD1122A41M5 LD1122A41M8 Overall Dimensions Unit:mm

A: Full cover 2: Resistance head & long type 4: Capacitance terminal type

AC.DC 12V

AC.DC 24V

AC.DC 110V

Industrial Control Components

AC.DC 230V

AC 230V

177

LD11 Indicator Light


Standard: IEC 60947-5

Order Information
Installation dimension Type Step-down Type Button colour Rated voltage AC 400V Reference LD1122A41Q7 LD1122A41Q3 LD1122A41Q4 LD1122A41Q5 LD1122A41Q8 22:22 B: Half cover 2: Resistance head&long type terminal 4: Capacitance type AC.DC 6V LD1122B21T7 LD1122B21T3 LD1122B21T4 LD1122B21T5 LD1122B21T8 AC.DC 12V LD1122B21J7 LD1122B21J3 LD1122B21J4 LD1122B21J5 LD1122B21J8 AC.DC 24V LD1122B21B7 LD1122B21B3 LD1122B21B4 LD1122B21B5 LD1122B21B8 AC.DC 110V LD1122B21F7 LD1122B21F3 LD1122B21F4 LD1122B21F5 LD1122B21F8 AC.DC 230V LD1122B21M7 LD1122B21M3 LD1122B21M4 LD1122B21M5 LD1122B21M8 AC 230V LD1122B41M7 LD1122B41M3 LD1122B41M4 LD1122B41M5 LD1122B41M8 AC 400V LD1122B41Q7 LD1122B41Q3 LD1122B41Q4 LD1122B41Q5 LD1122B41Q8
Industrial Control Components

Overall Dimensions

Unit:mm

178

LD11 Indicator Light


Standard: IEC 60947-5

Order Information
Installation dimension 22:22 Type Step-down Type Button colour Rated voltage AC.DC 6V Reference LD1122C21T7 LD1122C21T3 LD1122C21T4 LD1122C21T5 LD1122C21T8 AC.DC 12V LD1122C21J7 LD1122C21J3 LD1122C21J4 LD1122C21J5 LD1122C21J8 AC.DC 24V LD1122C21B7 LD1122C21B3 LD1122C21B4 LD1122C21B5 LD1122C21B8 AC 230V LD1122C41M7 LD1122C41M3 LD1122C41M4 LD1122C41M5 LD1122C41M8 AC 400V LD1122C41Q7 LD1122C41Q3 LD1122C41Q4 LD1122C41Q5 LD1122C41Q8 Overall Dimensions Unit:mm

C: Full cover 2: Resistance head & short type terminal 4: Capacitance type

Industrial Control Components

179

LD11 Indicator Light


Standard: IEC 60947-5

Order Information
Installation dimension 22:22 Type Step-down Type Button colour Rated voltage AC.DC 6V Reference LD1122D21T7 LD1122D21T3 LD1122D21T4 LD1122D21T5 LD1122D21T8 AC.DC 12V LD1122D21J7 LD1122D21J3 LD1122D21J4 LD1122D21J5 LD1122D21J8 AC.DC 24V LD1122D21B7 LD1122D21B3 LD1122D21B4 LD1122D21B5 LD1122D21B8 AC 230V LD1122D41M7 LD1122D41M3 LD1122D41M4 LD1122D41M5 LD1122D41M8 AC 400V LD1122D41Q7 LD1122D41Q3 LD1122D41Q4 LD1122D41Q5 LD1122D41Q8 Overall Dimensions Unit:mm

D: Half cover 2: Resistance head&short type terminal 4: Capacitance type

Industrial Control Components

180

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Function

LAY5 series of pushbutton switches provide: Control and indicate the status of the circuit

Technical Data
Usage mode Rated voltage (Ue) V AC-15 Rated current (Ie) A DC-13 Rated voltage (Ue) V Rated current (Ie) A 105 105 Rated valve 380 2 230 0.5 3 0 Flush type , 1 0 Illuminated 1 Emergency stop, Selective-type, Key-tpye Electric endurance AC6( Flush type ) DC3( Illuminated ) 1 Emergency stop, Selective-type, Key-tpye 6 IP55 V 6 12 24 110 230 380 230 3.3 110 1.1

Mechanical endurance

Rated thermal current (Ith) A Protect degree Illuminated pushbutton Power supplier voltage LED Neon lamp Filament lamp

Working Condition
Temperature Ralative humidity Above sea level Pollution grade -5 ~+40 90%(20 )
Industrial Control Components

50%(40 ) 2000m 3

181

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Flush Button Name LAY5 Material Type Color NO + NC Reference Unit: MM Dimension

B Metal

A Momentary

1 White 2 Black 3 Green 4 Red 5 Yellow 6 Blue

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5BA15 LAY5BA25 LAY5BA31 LAY5BA42 LAY5BA55 LAY5BA65

E Plastic

A Momentary

1 White 2 Black 3 Green 4 Red 5 Yellow 6 Blue

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5EA15 LAY5EA25 LAY5EA31 LAY5EA42 LAY5EA55 LAY5EA65

Selective Button Switch Name LAY5

Unit: MM Material Type Operation NO + NC Reference Dimension

B Metal

D Selective button with short handle

2:2p 3:3p 4:2 p 5:3p

C R L C R C R L C R

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5BD21 LAY5BD25 LAY5BD33 LAY5BD45 LAY5BD53

Industrial Control Components

182

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Selective Switches Name Material LAY5 Unit: MM Type Operation NO + NC Reference Dimension

E Plastic

D Selective switch with short handle

2:2 p 3:3 p 4:2p 5:3 p

C R L C R C R L C R

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5ED21 LAY5ED25 LAY5ED33 LAY5ED45 LAY5ED55

B Metal

J Selective 2:2 p switch with short handle 3:3 p 4:2p 5:3 p

C R L C R C R L C R

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5BJ21 LAY5BJ25 LAY5BJ33 LAY5BJ45 LAY5BJ55

E Plastic

J Selective switch with short handle

2:2 p 3:3 p 4:2p 5:3 p

C R L C R C R L C R

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5EJ21 LAY5EJ25 LAY5EJ33 LAY5EJ45 LAY5EJ55

Industrial Control Components

183

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Key-operated Selective Switches Name LAY5 Material Type Operation NO + NC Reference Unit: MM Dimension

B Metal

G Key-operated 2:2 p selective switches 3:3 p 4:2p reset 5:3 p reset

C R L C R C R L C R

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5BG21 LAY5BG25 LAY5BG33 LAY5BG45 LAY5BG55

E Plastic

G Key-operated 2:2p selective switches 3:3 p 4:2p reset 5:3 p reset

C R L C R C R L C R

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5EG21 LAY5EG25 LAY5EG33 LAY5EG45 LAY5EG55

Mushroom Button Name LAY5 Material Type Color NO + NC Reference

Unit: MM Dimension

B Metal

C:

40 Mushroom

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5BC31 LAY5BC42 LAY5BC35 LAY5BC45

Industrial Control Components

184

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Mushroom Button Name LAY5 Material Type Color NO + NC Reference Unit: MM Dimension

B Metal

R:

60 Mushroom

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5BR31 LAY5BR42 LAY5BR35 LAY5BR45

E Plastic

C:

40 Mushroom

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5EC31 LAY5EC42 LAY5EC35 LAY5EC45

E Plastic

R:

60 Mushroom

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5ER31 LAY5ER42 LAY5ER35 LAY5ER45

Industrial Control Components

185

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Emergency Stop Button Name LAY5 Material Type Head Color NO + NC Reference Unit: MM Dimension

B Metal

S: Emergency

4:

30

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5BS431 LAY5BS442 LAY5BS435 LAY5BS445

B Metal

S: Emergency

5:

40

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5BS531 LAY5BS542 LAY5BS535 LAY5BS545

B Metal

S: Emergency

6:

60

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5BS631 LAY5BS642 LAY5BS635 LAY5BS645

Industrial Control Components

186

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Emergency Stop Button Name LAY5 Material Type Head Color NO + NC Reference Unit: MM Dimension

E Plastic

S: Emergency

4:

30

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5ES431 LAY5ES442 LAY5ES435 LAY5ES445

E Plastic

S: Emergency

5:

40

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5ES531 LAY5ES542 LAY5ES535 LAY5ES545

E Plastic

S: Emergency

6:

60

3 Green 4 Red

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

LAY5ES631 LAY5ES642 LAY5ES635 LAY5ES645

Industrial Control Components

187

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Two-head Button Name LAY5 Material Type Head No.of head NO + NC Reference Unit: MM Dimension

B Metal

L8: Two-head 3: Flush button

2: 2

5: 1NO+1NC

LAY5BL8325

B Metal

L8 : Two-head 4: One high, one low

2: 2

5: 1NO+1NC

LAY5BL8425

Industrial Control Components

188

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Illuminated Pushbutton Switches Name LAY5 Material Type Color Voltage NO + NC Light

*
B Metal W3 Flush 1 White 3 Green 4 Red 5 Yellow 6 Blue 7 Pure white 8 Pure blue T:6V B:24V F:110V N:230V Q:380V 1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

*
N Neon L LED Blank: Filament

Reference

LAY5BW31*5 LAY5BW33*1

* * LAY5BW34*2 * LAY5BW35*5 * LAY5BW36*5 * LAY5BW37*5 * LAY5BW38*5 *

B Metal

W8:Two head

4 One high one low

T:6V B:24V F:110V N:230V Q:380V

5: 1NO+1NC N Neon L LED Blank: Filament

LAY5BW84*5*

E Plastic

W3 Flush

1 White 3 Green 4 Red 5 Yellow 6 Blue 7 Pure white 8 Pure blue

T:6V B:24V F:110V N:230V Q:380V

1: 1NO 2: 1NC 3: 2NO 4: 2NC 5: 1NO+1NC

N Neon L LED Blank: Filament

LAY5EW31*5 LAY5EW33*1

* * LAY5EW34*2 * LAY5EW35*5 * LAY5EW36*5 * LAY5EW37*5 * LAY5EW38*5 *

Industrial Control Components

E Plastic

W8:Two head

4 One high one low

T:6V B:24V F:110V N:230V Q:380V

5: 1NO+1NC N Neon L LED Blank: Filament

LAY5EW84*5*

Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp.
189

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Indication Lamp Name LAY5 Material Type Voltage Color Light Unit: MM

*
B Metal V: Indication T:6V B:24V F:110V N:230V Q:380V 1 White 3 Green 4 Red 5 Yellow 6 Blue 7 Pure white 8 Pure blue

*
N Neon L LED Blank: Filament

Reference

Dimension

LAY5BV*1* LAY5BV*3* LAY5BV*4* LAY5BV*5* LAY5BV*6* LAY5BV*7* LAY5BV*8*

Base Name LAY5 Type Contact Reference Dimension

BE Auxiliary contact

101: 1NO 102: 1NC 103: 2NO 104: 2NC 105: 1N0+1NC

LAY5BE101 LAY5BE102 LAY5BE103 LAY5BE104 LAY5BE105

Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp.

Industrial Control Components

190

LAY7 Pushbutton Switches


Standard: IEC 60947-5

Function

LAY7 series of pushbutton switches provide: Control and indicate the status of the circuit

Technical Data
Usage mode Rated voltage (Ue) V AC-15 Rated current (Ie) A DC-13 Rated voltage (Ue) V Rated current (Ie) A Rated valve 660 1.1 440 0.25 380 2 230 0.5 230 3.3 110 1

Mechanical endurance 105 Electric endurance Rated thermal current l Operation frequency Contact resistance Protect degree Illuminated pushbutton Power supplier voltage Working voltage Lifetime (Ue)V h 105
th

3 0 Flush type , 1 0 Illuminated 0 . 5 Emergency stop, Selective-type, Key-tpye , 6 Flush type , 1 Illuminated 0 . 5 Emergency stop, Selective-type, Key-tpye , , 10 1200 50 IP55 Filament lamp 6, 12, 24 1000 Neon lamp 110, 220, 380 2000 LED 6, 12, 24 3000

T /h m

Working Condition
Temperature Ralative humidity Above sea level Pollution grade -5 ~+40 90%(20 )

50%(40 ) 2000m 3

Industrial Control Components

191

LAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Flush Button Name LAY7 NO + NC Type Color Installation Reference Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

BN Momentary

1 White 2 Black 3 Green 4 Red 5 Yellow 6 Blue

2 3 4

22 25 30

LAY711BN12 LAY711BN22 LAY711BN32 LAY711BN42 LAY711BN52 LAY711BN62

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

BNZS Maintained

3 Green 4 Red

2 3 4

22 25 30

LAY711BNZS32 LAY711BNZS42

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

GN Momentary

3 Green 4 Red

2 3 4

22 25 30

LAY711GN32 LAY711GN42

Industrial Control Components

10: 1NO 01: 1NC 20: 2NO 02: 2NC

GNZS Maintained

3 Green 4 Red

2 3 4

22 25 30

LAY711GNZS32 LAY711GNZS42

11: 1NO+1NC

192

LAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Flush Button Name LAY7 NO + NC Type Color Installation Reference Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

JN Full protection

3 Green 4 Red

2 3 4

22 25 30

LAY711JN32 LAY711JN42

Selective Switches Name LAY7 NO + NC Type Operation Color Installation Reference

Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

X Selective button with short handle

20:2p 21:2p 30:3p 31:3p 33:3p

C R C R L C R L C R L C R

2 Black 4 Red

2 4

22 25 30

LAY711X2022 LAY711X2132 LAY711X3042 LAY711X3122 LAY720X3022

3 Green 3

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

XB Selective 20:2 button with long handle 21:2 30:3 31:3 33:3

C R C R L C R L C R L C R

2 Black 4 Red

2 4

22 25 30

LAY711XB2022 LAY711XB2132 LAY711XB3042 LAY720XB3022 LAY720XB3322

Industrial Control Components

3 Green 3

193

LAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Key-operated Selective Switches Name LAY7 NO + NC Type Operation Installation Reference Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

Y Key-operated

20:2p 21:2p 30:3p 31:3p 33:3p

C R C R L C R L C R L C R

2 3 4

22 25 30

LAY711Y202 LAY711Y212 LAY711Y302 LAY711Y312 LAY720Y332

Mushroom Button Name LAY7 NO + NC Type Color Installation Reference

Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

M Momentary

3 Green 4 Red

2 3 4

22 25 30

LAY711M32 LAY711M42

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC
Industrial Control Components

MZS Maintained

3 Green 4 Red

2 3 4

22 25 30

LAY711MZS32 LAY711MZS42

194

LAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Emergency Stop Button Name LAY7 NO + NC Type Color Installation Reference Unit: MM Dimension

10: 1NO 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC

ZS:Emergency

3: Green 4: Red

2: 22 3: 25 4: 30

LAY710ZS32 LAY701ZS42

LAY711ZS32 LAY711ZS42

Illuminated Pushbutton Switches Name LAY7 10: 1NO D: Momentary 01: NC (Illuminated) 20: 2NC 02: 2NC 11: 1NO+1NC 3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue NO + NC Type Color Voltage Installation Light N Neon L LED Blank: Filament

Unit: MM

2: 22 T: 6V B: 24V 3: 25 F: 110V 4: 30 N: 230V Q: 380V

Reference LAY711D3*2 * LAY711D4*2 * LAY711D5*2 LAY711D6*2

Dimension

* * LAY711D7*2 * LAY711D8*2 *
LAY711DZS4*2* LAY711DZS5*2* LAY711DZS6*2* LAY711DZS8*2* LAY711DZS7*2 * LAY711DZS2*2 *

DZS: Maintained 10: 1NO (Illuminated) 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC

3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue

T: 6V 2: 22 B: 24V 3: 25 F: 110V 4: 30 N: 230V Q: 380V

N Neon L LED Blank: Filament

DM: Momentary 10: 1NO (Illuminated) 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC

3: Green 4: Red

T: 6V 2: 22 B: 24V 3: 25 F: 110V 4: 30 N: 230V Q: 380V

N Neon L LED Blank: Filament

LAY711DM3*2 * LAY711DM4*2

Industrial Control Components

DMZS: Maintained 3: Green 10: 1NO 4: Red (Illuminated) 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC

T: 6V 2: 22 B: 24V 3: 25 F: 110V 4: 30 N: 230V Q: 380V

N Neon L LED Blank: Filament

LAY711DMZS3*2 LAY711DMZS4*2

* *

Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp.
195

LAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Illuminated Selective Switches Name LAY7 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC 30:3p L C R XD: Selective 20:2p (Illuminated) C R 3 Green 4 Red NO + NC Type Operation Color Voltage Install Light Unit: MM

*
T: 6V B: 24V F: 110V N: 230V Q: 380V 2 3 4 22 25 30

*
N Neon L LED Blank: Filament

Reference

Dimension

LAY711XD203*2 LAY711XD204*2

* * LAY711XD303*2 * LAY711XD304*2 *

Indication Lamp Name LAY7 Type Color Voltage Install

Unit: MM

*
XD1 Filament XD2 Neon XD3 LED 1 White 3 Green 4 Red 5 Yellow 6 Blue 7 Pure white 8 Pure blue T: 6V B: 24V F: 110V N: 230V Q: 380V 2 22

Reference

Dimension

LAY7XD11*2 LAY7XD23*2 LAY7XD34*2 LAY7XD15*2 LAY7XD26*2 LAY7XD37*2 LAY7XD38*2

Base Name LAY7


Industrial Control Components

Unit: MM Type Contact Reference Dimension

BE Auxiliary contact

101: 1NO 102: 1NC 103: 2NO 104: 2NC 105: 1N0+1NC

LAY7BE101 LAY7BE102 LAY7BE103 LAY7BE104 LAY7BE105

Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp.

196

LAY8 Pushbutton Switches


Standard: IEC 60947-5

Function

LAY8 series of pushbutton switches provide: Control and indicate the status of the circuit

Technical Data
Usage mode AC-15 DC-13 Rated voltage (Ue) V Rated current (Ie) A Rated voltage (Ue) V Rated current (Ie) A Rated valve 660 1.5 440 0.2 380 2.5 230 0.4 230 4.5 110 0.8

Mechanical endurance 105 Electric endurance 105

3 0 Flush type , 3 Selective 0 . 5 Emergency stop, Key-tpye 6( Flush type ) , 1( Illuminated ) 0 . 5 Emergency stop, Key-tpye 10 50 IP55 12 50 24 36 48 110 220 AC 20 230 380

Rated thermal current(Ith)A Contact resistance Protect degree Illuminated pushbutton Rated working voltage (Ue)V 6 Power supply Rated working current (Ie)mA m

AC, DC

Working Condition
Temperature Ralative humidity Above sea level Pollution grade -5 ~+40 90%(20 )

50%(40 ) 2000m 3

Industrial Control Components

197

LAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Flush Button Name LAY8 NO + NC Type Color Reference Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

BN Momentary

1 White 2 Black 3 Green 4 Red 5 Yellow 6 Blue

LAY811BN1 LAY811BN2 LAY811BN3 LAY811BN4 LAY811BN5 LAY811BN6

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

BNZS Maintained

3 Green 4 Red 5 Yellow

LAY811BNZS3 LAY811BNZS4 LAY811BNZS5

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

S Waterproof

3 Green 4 Red 5 Yellow

LAY811S3 LAY811S4 LAY811S5

Industrial Control Components

198

LAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Selective Switches Name LAY8 NO + NC Type Operation Color Reference Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

X Selective button with short handle

20:2p 21:2p 30:3p 31:3p 33:3p

C R C R L C R L C R L C R

2 Black 3 Green 4 Red

LAY811X202 LAY811X213 LAY811X304 LAY811X312 LAY820X332

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

XB Selective button with long handle

20:2p 21:2p 30:3p 31:3p 33:3p

C R C R L C R L C R L C R

2 Black 3 Green 4 Red

LAY811XB202 LAY811XB213 LAY811XB304 LAY811XB312 LAY820XB332

Industrial Control Components

199

LAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Key-operated Selective Switch Name LAY8 NO + NC Type Operation Reference Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

Y Key-operated

20:2p 21:2p 30:3p 31:3p 33:3p

C R C R L C R L C R L C R

LAY811Y20 LAY811Y21 LAY820Y30 LAY811Y31 LAY811Y33

Mushroom Button Name LAY8 NO + NC Type Color Reference

Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

M Momentary

3 Green 4 Red

LAY811M3 LAY811M4

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

MZS Maintained

3 Green 4 Red

LAY811MZS3 LAY811MZS4

Industrial Control Components

200

LAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Emergency Stop Button Name LAY8 NO + NC Type Color Reference Unit: MM Dimension

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

ZS Emergency

3 Green 4 Red

LAY811ZS3 LAY811ZS4

Illuminated Pushbutton Switches Name LAY8 NO + NC Type Color Voltage Power

Unit: MM

*
10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC D: Momentary (Illuminated) 3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue T: 6V B: 24V F: 110V N: 230V Q: 380V 2: AC/DC 4: AC

Reference

Dimension

LAY811D3*4 LAY811D4*4 LAY811D5*2 LAY811D6*2 LAY811D7*2 LAY811D8*2

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

DZS: Maintained (Illuminated)

3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue

T: 6V B: 24V F: 110V N: 230V Q: 380V

2: AC/DC 4: AC

LAY811DZS3*4 LAY811DZS4*4 LAY811DZS5*2 LAY811DZS6*2 LAY811DZS7*4 LAY811DZS8*4


Industrial Control Components

10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO+1NC

DS:Waterproof (Illuminated)

3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue

T: 6V B: 24V F: 110V N: 230V Q: 380V

2: AC/DC 4: AC

LAY811DS3*4 LAY811DS4*4 LAY811DS5*2

Note:Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V The pure white and pure blue are only available for LED lamp.

201

LAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information

Base Name LAY8 Type Contact Reference

Unit: MM Dimension

BE Auxiliary contact

101: 1NO 102: 1NC 103: 2NO 104: 2NC 105: 1N0+1NC

LAY8BE101 LAY8BE102 LAY8BE103 LAY8BE104 LAY8BE105

Industrial Control Components

202

RT16 Fuse
Standard: IEC 60269

Function

RT16 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current

Order Information
Fuse-link RT16-00 Rate current In(A) Suitable fuse bases 2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 160 RT16-1 80 100 125 160 200 250 RT16-2 125 160 200 250 300 315 355 400 RT16-3 315 355 400 450 500 630 RT16-3 850 RT16-2 660 RT16-1 450 RT16-00 Weight(g) 170 Reference RT16002 RT16004 RT16006 RT16008 RT160010 RT160012 RT160016 RT160020 RT160025 RT160032 RT160040 RT160050 RT160063 RT160080 RT1600100 RT1600125 RT1600160 RT16180 RT161100 RT161125 RT161160 RT161200 RT161250 RT162125 RT162160 RT162200 RT162250 RT162300 RT162315 RT162355 RT162400 RT163315 RT163355 RT163400 RT163450 RT163500 RT163630
Industrial Control Components

203

RT16 Fuse
Standard: IEC 60269

Order Information
Fuse Base RT16-00 RT16-1 RT16-2 RT16-3 Rate current In(A) 160 250 400 630 Material Ceramic Resin Ceramic Resin Ceramic Resin Ceramic Resin 1280 1150 700 Weight(g) 200 Reference RT1600ZT RT1600ZS RT161ZT RT161ZS RT162ZT RT162ZS RT163ZT RT163ZS

Technical Data
Rated working current Rated operation voltage Rated breaking capacity 2-630A 500/660V 120KA(500V), 50KA(660V)

Accessory-puller
Material ABS(frame resistance) Usage Assemble and replace RT16 fuse Reference RT16C

Industrial Control Components

204

RT16 Fuse
Standard: IEC 60269

Overall Dimensions
Unit: mm

Type a b c d e A B C1 C2 D E F G

RT16-00 78.5 29 57 49 6 30 120 61 85 100 25 7.5

RT16-1 135 48 62 67 6 58 200 83 96 175 25 10.5 30

RT16-2 150 58 72 67 6 64 250 99 112 200 25 10.5 30

RT16-3 150 67 85 67 6 64 250 105 120 210 25 10.5


Industrial Control Components

30

205

RT18 Fuse
Standard: IEC 60269

Function

RT18 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current

Order Information
Cylindrical Fuse RT18-32 Rate current In(A) 2 4 6 8 10 12 16 20 25 32 RT18-63 2 4 6 8 10 12 16 20 25 32 40 50 63 20 Weight(g) 8 Reference RT1810382 RT1810384 RT1810386 RT1810388 RT18103810 RT18103812 RT18103816 RT18103820 RT18103825 RT18103832 RT1814512 RT1814514 RT1814516 RT1814518 RT18145110 RT18145112 RT18145116 RT18145120 RT18145125 RT18145132 RT18145140 RT18145150 RT18145163

Industrial Control Components

206

RT18 Fuse
Standard: IEC 60269

Order Information
Rate current In(A) 32 Weight (g) 82

Holder of fuse RT18-32X

Pole 1P 2P 3P

Note Material:Resin With Indicator

Reference RT1832ZXB RT1832Z2XB RT1832Z3XB

RT18-32

1P 2P 3P

32

Material:Resin Without Indicator

82

RT1832ZB RT1832Z2B RT1832Z3B

RT18-32X

1P 2P 3P

32

Material:Nylon With Indicator

82

RT1832ZX RT1832Z2X RT1832Z3X

RT18-32

1P 2P 3P

32

Material:Nylon Without Indicator

82

RT1832Z RT1832Z2 RT1832Z3

RT18-63X

1P 2P 3P

63

Material:Resin With Indicator

206

RT1863ZXB RT1863Z2XB RT1863Z3XB

RT18-63

1P 2P 3P

63

Material:Resin Without Indicator

206

RT1863ZB RT1863Z2B RT1863Z3B

Technical Data
Rated working current Rated operation voltage Rated breaking capacity 2-63A 380V 100KA
Industrial Control Components

207

RT18 Fuse
Standard: IEC 60269

Overall Dimensions
Unit: mm

Cylindrical Fuse Type RT18-32 RT18-63 Size 1038 1451 L 380.6 51 +0.6 -1.0 C 10.30.1 14.30.1 Hmax 10.5 13.8

Holder of fuse Type RT18-32 RT18-63


Industrial Control Components

A 63 78

B 60 76

C 79 103

D 35 35

E 80 110

F 18 25

G 54 75

208

CCF Series Cable Connector

Technical Data
Thread specification: International metric standard Material: Nylon 66 Working temp.: -40~+100 Max temp. in short time: +120. Installation: Standard threaded hole Colour: Black & gray

Order Information
Cabel range (mm)
7.6-4.6 10-6 14-9 18-13 25-18 30-24 41-30 51-40 7-3.5 8-4.5 10.5-6 12.5-7.5 14-8.5 18-12.5 25-18 30-23 39-30 45-35

Thread external diameter (mm)


12 16 20 25 32 40 50 63 7 9 11 13.5 16 21 29 36 42 48

Panel hole (mm)


12.5 16.5 20.5 25.5 33 41 51 64 12.5 15.2 18.6 20.4 22.5 28.3 37 47 54 59.3

Thread length (mm)


8.5 15 15 15 15 20 22 25 8 8.5 9 9.6 10 12 15 15 15.5 15.5

Spanner size A&F


18/19 22/22 27/27 33/33 41/41 50/50 62/62 75/75 17/19 22/19 24/22 27/24 30/27 36/33 46/41 57/50 64/62 70/65

Reference Black
CCFMG12IP68B CCFMG16IP68B CCFMG20IP68B CCFMG25IP68B CCFMG32IP68B CCFMG40IP68B CCFMG50IP68B CCFMG63IP68B --------C ------------B B B B

Gray
CCFMG12IP68W CCFMG16IP68W CCFMG20IP68W CCFMG25IP68W CCFMG32IP68W CCFMG40IP68W CCFMG50IP68W CCFMG63IP68W CCFPG7IP54W CCFPG9IP54W CCFPG11IP54W CCFPG135IP54W CCFPG16IP54W CCFPG21IP54W CCFPG29IP54W CCFPG36IP54W CCFPG42IP54W CCFPG48IP54W
Industrial Control Components

209

Industrial Plugs&Sockets Overview

CDPM Moving Industrial plugs Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A

211

CDP Fixed Industrial Plugs Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A

212

CDSM Moving Industrial Sockets Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A

213

CDSF Fixed Industrial Sockets Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A

214

Industrial Control Components

CDPS Multi-function Plugs and Sockets Pole: 2P+E Voltage:110V, 230V Current:16A

215

210

CDPM Moving Industrial Plugs


Standard: IEC 60309-1-2

Moving Industrial Plugs

16Amp

32Amp

PG

63 67 2P+E 230-250 125

CDPM363IP67
3

63Amp
4 5

125Amp
3 4 5 295 295 295 124 124 124 50 50 50

CDPM3125IP67

a b c

230 230 230 109 109 109 36 36 36

63 67 3P+E 400-415 125

CDPM463IP67

CDPM4125IP67

Industrial Control Components

63 67 3P+N+E 400-415 125

CDPM563IP67

CDPM5125IP67

211

CDP Fixed Industrial Plugs


Standard: IEC 60309-1-2

Fixed Industrial Plugs

CDP316IP441

CDP332IP441

CDP316IP44

CDP332IP44

CDP416IP44

CDP432IP44

CDP516IP44

CDP532IP44

67

230~250

63

CDP363IP67

63Amp a 3 193 122 157 109 19 6 288 127 29 4 193 122 157 109 19 6 288 127 29 5 193 122 157 109 19 6 288 127 29

67 3P+E
Industrial Control Components

400~415

63

CDP463196

b c d e f g h PG

67 3P+N+E

400~415

63

CDP5631967

212

CDSM Moving Industrial Sockets


Standard: IEC 60309-1-2

Moving Industrial Sockets

CDSM316IP441

16Amp Poles a b 3 4 5

32Amp 3 4 5

130 131 139 149 149 154 66 76 90 90 90 100

63 67 2P+E 230~250 125

CDSM363IP67

PG

CDSM3125IP67

63 67 3P+E 400~415 125

CDSM463IP67
a b PG

63Amp 3 4 5 240 240 240 112 112 112 36 36 36

125Amp 3 4 5
Industrial Control Components

CDSM4125IP67

300 300 300 126 126 126 50 50 50

63 67 3P+N+E 400~415 125

CDSM563IP67

CDSM5125IP67

213

CDSF Fixed Industrial Sockets


Standard: IEC 60309-1-2

Fixed Industrial Sockets


Pole No. IP Nominal voltage(V) Nominal current(A) 16 44 2P+E 110~130 32 CDSF332IP441 Reference

CDSF316IP441

16 2P+E 44 230~250 32

CDSF316IP44

CDSF332IP44

16 3P+E 44 400~415 32 230~400 3P+N+E 44 240~415 32 16

CDSF416IP44

16Amp Poles a b M 3 86 25 4 90 25 5 96 25 3 128 128 129

32Amp 5

141 141 143 97 25 97 104 25

CDSF432IP44 CDSF516IP44

25

CDSF532IP44

63 67 2P+E 230~250 125


Industrial Control Components

CDSF363IP67

CDSF3125IP67

63 3P+E 67 400~415 125

CDSF463IP67 Poles a CDSF4125IP67 b c d e f g h PG

63Amp
3 4 5

125Amp
3 4

193 193 193 122 122 122 157 157 157 109 109 109 19 6 19 6 19 6

220 220 220 140 140 140 185 185 185 130 130 130 17 8 17 17 8

230~400 67 3P+N+E 240~415

63

CDSF563IP67

270 270 270 130 130 130 29 29 29

320 320 320 150 150 150 36 36 36

125

CDSF5125IP67

214

CDPS Multi-function Plugs&Sockets


Standard: IEC 60309-1-2

Multi-function Plugs and Sockets

1 Plug

1 Plug

1 Plug

1 Plug

Industrial Control Components

215

Copper Terminal Block Overview

TB010

217

Hole:4, 6, 8, 10, 12, 14, 16 Hole diameter(mm):5.2, 6 Screw dimension(mm):M4*8, M5*10 Max current(A):100, 150

TB019

218

Hole:4, 6, 8, 10, 12, 14, 16 Hole diameter(mm):5.2, 6 Screw dimension(mm):M4*8, M5*10 Max current(A):100, 150

TB007

219

Hole:6, 8, 10, 12, 14, 16 Hole diameter(mm):5.2, 6 Screw dimension(mm):M4*8, M5*10 Max current(A):100, 150

TB043

220

Hole:78, 109, 116, 133 Hole diameter(mm):5~9 Screw dimension(mm):M4*8~M6*12 Max current(A):100~200

Industrial Control Components

TB112

220

Hole:2x7, 2x15, 4x7, 4x11, 4x15 Hole diameter(mm):5.2 Screw dimension(mm):M4 Max current(A):125

216

TB010 Series Copper Terminal Block

Order Information

Industrial Control Components

217

TB019 Series Copper Terminal Block

Order Information

Industrial Control Components

218

TB007 Series Copper Terminal Block

Order Information

Industrial Control Components

219

TB112 Series Copper Terminal Blocks TB043 Series Copper Terminal Blocks

Order Information

65 132 65 132

Industrial Control Components

220

DIN Rail Series

Order Information

Thickness(mm)
0.8 0.9 1.0 * means length 1000=1000mm 2000=2000mm 5000=5000mm

Reference
CDIN01E* CDIN01N* CDIN02T*

Overall Dimensions
Unit:mm

Industrial Control Components

221

A Company to Serve You Where You Are

E-mail Address:info.OBD@delixi-electric.com Algeria Phone: +213 5 600 600 11 Chile Phone:+56-2-4822100 Colombia / Venezuela / Ecuador / Peru / Bolivia Phone:+57 3212056531 Egypt Phone:+20 10 011 3238 - +20 11 811 3546 Israel Phone:+972 543311087 Kenya / Tanzania / Uganda / Rwanda / Burundi Phone:+97150 5536433 Malaysia Phone:+601 93227688 Morocco Phone:+212 661 114 6999 Nigeria / Ghana / Liberia Phone:+234 8035059040 Pakistan Phone:+92 300 8465 789 Philippines / Laos / Bangladesh Phone:+86 158 6807 8915 Russia / Kazakhstan Phone: +7 916 693 59 84 Santo Domingo / Trinidad and Tobago / Jamaica Phone: +809 861 5803 Saudi Arabia / Yemen Phone:+966-50 440 62 69 Turkey / Romania / Serbia / Bulgaria / Macedonia / Montenegro / Albania / Moldova / Syria / Lebanon / Jordan / Iran / Iraq / Central Asia Phone:+90 5335256771 UAE / Qatar / Oman / Bahrain / Kuwait Phone:+97150 5536433 Vietnam / Cambodia Phone:+8490 381 3973