You are on page 1of 10

Solenoid Operated Cartridge Valves

Cartridge Type
Normally Open Normally Closed

Page

2-way, Direct Acting, Poppet Directional Valve


1

132

Normally Open
2

Normally Closed
2

2-way, Directional Spool Valve, Pilot Capacity

133

Normally Open

Normally Closed

2-way, Soft Shift, Directional Spool Valve


1

134

Normally Open

3-way, 2-position, Direct Acting, Directional Poppet Valve


1 3

135

Normally Open

Normally Open

3-way, 2-position, Directional Spool Valve, Pilot Capacity


2 3

136

2 3

3-way, 2-position, Soft Shift, Directional Spool Valve


1 3

137

2 4

4-way, 2-position, Directional Spool Valve


3 1

138

Coil A

Coil B

4-way, 3-position, Spring Centred, Directional Spool Valve

139

Intl Shortcut Catalogue #999-901-312

131

Solenoid Operated Cartridge Valves 2-WAY, DIRECT ACTING, POPPET DIRECTIONAL VALVE
d
2 2

Normally Open

Normally Closed Typical Cartridge Model Code DTDA *** Cartridge Dimensions c*** b M,X,S D,L,T 22,2 89,2 114,3 Installation Torque (Nm) 45 - 50

b
Locating Shoulder

Nominal Capacity 40 L/min.

Cavity T - 13A

a 35,0

d 37,3

a
2 Port Port 1

***An additional 50,8 mm clearance is needed for coil installation and removal.

Performance Curves DTDA-MC*


420

DTDA-MH*
420

DTDA-SC*
400

DTDA-SH*
400

DTDA-***
Pressure Differential vs. Flow
20

Valve Performance Limits at 10% Undervoltage and Stabilized Coil Temperature


P = bar P = bar P = bar
350 280 210 140 70 0 350 280 210 140 70 30 45 60 0

P = bar

1 to 2

P = bar

2 to 1

300 200 100 0

300 200 100 0 10

2 to 1 1 to 2

15 10 5 0 10 20

DTDA-*HN

2 to 1
15

1 to 2
15 30 45 60

2 to 1

1 to 2

DTDA-*CN

Flow = L/min.

Flow = L/min.

10

Flow = L/min.

20

30

40

50

Flow = L/min.

20

30

40

50

Flow = L/min.

30

40

50

60

I I I I I I I I I I I

Maximum operating pressure = 350 bar. Maximum valve leakage at 24 cSt = 0,6 cc/min. at 350 bar. Response time - typical = 50 ms. Manual override force requirement = 10 kg at 350 bar. Manual override stroke = 2,5 mm. Maximum switching frequency = 15000 cycles/hr. Viscosity range = 10 - 600 cSt. The solenoid tube assembly is fatigue rated for 350 bar service. This valve is direct actuated and requires no minimum hydraulic pressure for operation. The soft shift feature results in significantly longer response time over Suns standard solenoid. Response time is dependant on flow, pressure, coil voltage, oil viscosity and ambient temperature. Typical response time ranges from 150 ms to 300 ms. A wide variety of coil termination and voltage options are available. See Sun website: Products: Accessories: Coils.

OPTION ORDERING INFORMATION

DTDA M
Nominal Capacity D 40 L/min. Control* M Manual Override X No Manual Override S Soft Shift D Twist/Lock, Dual, Manual Override L Twist/Lock, Detent, Manual Override T Twist/Lock, Momentary, Manual Override * See page 178 for information on Control Options ** Consult the Sun website for complete information on Spool Configurations, the full line of Coil Options and Embedded Amplifier Coils/Controllers. Spool Configuration** H Normally Open C Normally Closed Coil Options** See page 187: Coil option information for Metal Housing (Round) Solenoid Cartridges.

Seal Material N Buna-N V Viton

Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products. 132
Intl Shortcut Catalogue #999-901-312

Solenoid Operated Cartridge Valves 2-WAY, DIRECTIONAL SPOOL VALVE, PILOT CAPACITY
d
2 2

Normally Open Nominal Capacity

Normally Closed Cartridge Dimensions Typical Cartridge Model Code DAAL *** Installation Torque (Nm) 35 - 40

b
2 Port

Cavity

c*** M,X,S D,L,T 108,7

Locating Shoulder
1 Port

1 L/min.

T - 8A

18,5

22,2

83,6

37,3

***An additional 50,8 mm clearance is needed for coil installation and removal.

Performance Curves DAAL-X**, DAAL-S**


Pressure Differential vs. Flow
40

P = bar

30 20 10 0 1 2 3 4

Flow = L/min.

I I I I I I I I I I I

Maximum operating pressure = 350 bar. Maximum valve leakage at 24 cSt = 0,6 cc/min. at 350 bar. Response time - typical = 50 ms. Manual override force requirement = 6,6 kg at 100 bar at port 1. Manual override stroke = 2,5 mm. Maximum switching frequency = 15000 cycles/hr. Viscosity range = 10 - 600 cSt. The solenoid tube assembly is fatigue rated for 350 bar service. This valve is direct actuated and requires no minimum hydraulic pressure for operation. The soft shift feature results in significantly longer response time over Suns standard solenoid. Response time is dependant on flow, pressure, coil voltage, oil viscosity and ambient temperature. Typical response time ranges from 150 ms to 300 ms. A wide variety of coil termination and voltage options are available. See Sun website: Products: Accessories: Coils.

OPTION ORDERING INFORMATION

DAA L X
Nominal Capacity A 1 L/min. Control* X No Manual Override M Manual Override S Soft Shift D Twist/Lock, Dual, Manual Override L Twist/Lock, Detent, Manual Override T Twist/Lock, Momentary, Manual Override Seal Material N Buna-N V Viton Spool Configuration** H Normally Open C Normally Closed Coil Options** See page 187: Coil option information for Metal Housing (Round) Solenoid Cartridges.

* See page 178 for information ** Consult the Sun website for complete information on Spool Configurations, on Control Options the full line of Coil Options and Embedded Amplifier Coils/Controllers. Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products.
Intl Shortcut Catalogue #999-901-312

133

Solenoid Operated Cartridge Valves 2-WAY, SOFT SHIFT, DIRECTIONAL SPOOL VALVE
d
2 2

Normally Open

Normally Closed Cartridge Dimensions Typical Cartridge Model Code DLDA *** Installation Torque (Nm) 45 - 50

Locating Shoulder

Nominal Capacity

Cavity

c*** M,X,S D,L,T 114,3

a
2 Port Port 1

45 L/min.

T - 13A

35,0

22,2

89,4

37,3

***An additional 50,8 mm clearance is needed for coil installation and removal.

Performance Curves DLDA-M** DLDA-S** DLDA-***


Pressure Differential vs. Flow
P = bar
H (1 to 2)
16 12 8 4 0
10 20 30 40 50

Valve Performance Limits at 10% Undervoltage and Stabilized Coil Temperature


400

C (2 to 1)

400

C (1 to 2)

P = bar

300 200 100 0 10 20 30 40 50

P = bar

300 200 100 0

C (2 to 1) H (2 to 1) H (1 to 2) C (1 to 2)

H (2 to 1) H (1 to 2) C (1 to 2)

H (2 to 1)
5

C (2 to 1)

Flow = L/min.

10 15 20 25 30 35 40 45

Flow = L/min.

Flow = L/min.

I I I I I I I I I I I

Maximum operating pressure = 350 bar. Maximum valve leakage at 24 cSt = 80 cc/min. at 210 bar. Response time - typical = 50 ms. Manual override force requirement = 10 kg at 350 bar. Manual override stroke = 2,5 mm. Maximum switching frequency = 15000 cycles/hr. Viscosity range = 10 - 600 cSt. This valve is direct actuated and requires no minimum hydraulic pressure for operation. The solenoid tube assembly is fatigue rated for 350 bar service. The soft shift feature results in significantly longer response time over Suns standard solenoid. Response time is dependant on flow, pressure, coil voltage, oil viscosity and ambient temperature. Typical response time ranges from 150 ms to 300 ms. A wide variety of coil termination and voltage options are available. See Sun website: Products: Accessories: Coils.

OPTION ORDERING INFORMATION

DL DA M
Nominal Capacity D 45 L/min. Control* M Manual Override X No Manual Override S Soft Shift D Twist/Lock, Dual, Manual Override L Twist/Lock, Detent, Manual Override Seal Material Twist/Lock, T Momentary, Manual Override N Buna-N Spool Configuration** H Normally Open C Normally Closed Coil Options** See page 187: Coil option information for Metal Housing (Round) Solenoid Cartridges.

V Viton * See page 178 for information ** Consult the Sun website for complete information on Spool Configurations, on Control Options the full line of Coil Options and Embedded Amplifier Coils/Controllers. Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products. 134
Intl Shortcut Catalogue #999-901-312

Solenoid Operated Cartridge Valves 3-WAY, 2-POSITION, DIRECT ACTING, DIRECTIONAL POPPET VALVE
d
2

1 3

Normally Open Cartridge Dimensions Typical Cartridge Model Code DWDA XAN Installation Torque (Nm) 45 - 50

b
3 Port 2 Port 1 Port

Nominal Capacity

Cavity

b M,X

c*** D,L,T 133,1

30 L/min.

T - 11A

34,8

22,2

108,2

37,3

Locating Shoulder

***An additional 50,8 mm clearance is needed for coil installation and removal.

Performance Curves
DWDA-XAN
Valve Performance Limits at 10% Undervoltage and Stabilized Coil Temperature
400

Pressure Differential vs. Flow


25

P = bar

P = bar

300 200 100 0 10 20

All Flow Directions

20 15 10 5

1 to 2 or 2 to 1 3 to 2 or 2 to 3
0
10 20 30 40

Flow = L/min.

30

40

Flow = L/min.

I I I I I I I I I I

Maximum operating pressure = 350 bar. Maximum valve leakage at 24 cSt = 0,6 cc/min. at 350 bar. Response time - typical = 50 ms. Manual override force requirement = 10 kg at 350 bar. Manual override stroke = 2,5 mm. Maximum switching frequency = 15000 cycles/hr. Viscosity range = 10 - 600 cSt. This valve is direct actuated and requires no minimum hydraulic pressure for operation. The solenoid tube assembly is fatigue rated for 350 bar service. A wide variety of coil termination and voltage options are available. See Sun website: Products: Accessories: Coils.

OPTION ORDERING INFORMATION

D WD A X A
Nominal Capacity D 30 L/min. Control* X No Manual Override M Manual Override D Twist/Lock, Manual Override L Twist/Lock, Detent, Manual Override Seal Material T Twist/Lock, Momentary, Manual Override * See page 178 for information on Control Options N Buna-N V Viton Spool Configuration** A Normally Open Port 1 to 2, Closed 2 to 3 Coil Options** See page 187: Coil option information for Metal Housing (Round) Solenoid Cartridges.

** Consult the Sun website for complete information on Spool Configurations, the full line of Coil Options and Embedded Amplifier Coils/Controllers.

Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products.
Intl Shortcut Catalogue #999-901-312

135

Solenoid Operated Cartridge Valves 3-WAY, 2-POSITION, DIRECTIONAL SPOOL VALVE, PILOT CAPACITY
d
1 1

2 3

2 3

Normally Open Port 1 to 2 Nominal Capacity

Normally Open Port 1 to 3 Cartridge Dimensions Typical Cartridge Model Code DBAL *** Installation Torque (Nm) 35 - 40

b
Port 3 Port 2 1 Port

Cavity

c*** M,X,S D,L,T 108,7

Locating Shoulder

1 L/min.

T - 9A

27,4

22,2

83,6

37,8

***An additional 50,8 mm clearance is needed for coil installation and removal.

Performance Curves DBAL-M**, DBAL-S


Pressure Differential vs. Flow
40

P = bar

30 20 10 0 1 2 3 4

Flow = L/min.

I I I I I I I I I I I

Maximum operating pressure = 350 bar. Maximum valve leakage at 24 cSt = 0,6 cc/min. at 350 bar. Response time - typical = 50 ms. Manual override force requirement = 6,6 kg at 100 bar at port 1. Manual override stroke = 2,5 mm. Maximum switching frequency = 15000 cycles/hr. Viscosity range = 10 - 600 cSt. This valve is direct actuated and requires no minimum hydraulic pressure for operation. The solenoid tube assembly is fatigue rated for 350 bar service. The soft shift feature results in significantly longer response time over Suns standard solenoid. Response time is dependant on flow, pressure, coil voltage, oil viscosity and ambient temperature. Typical response time ranges from 150 ms to 300 ms. A wide variety of coil termination and voltage options are available. See Sun website: Products: Accessories: Coils.

OPTION ORDERING INFORMATION

DBA L X
Nominal Capacity A 1 L/min. Control* X No Manual Override M Manual Override S Soft Shift D Twist/Lock, Dual, Manual Override L Twist/Lock, Detent, Manual Override Seal Material T Twist/Lock, Momentary, Manual Override * See page 178 for information on Control Options N Buna-N V Viton Spool Configuration** H Normally Open Port 1 to 2, Closed 1 to 3 C Normally Open Port 1 to 3, Closed 1 to 2 Coil Options** See page 187: Coil option information for Metal Housing (Round) Solenoid Cartridges.

** Consult the Sun website for complete information on Spool Configurations, the full line of Coil Options and Embedded Amplifier Coils/Controllers.

Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products.
Intl Shortcut Catalogue #999-901-312

136

Solenoid Operated Cartridge Valves


3-WAY, 2-POSITION, SOFT SHIFT, DIRECTIONAL SPOOL VALVE
d
2

1 3

DMDA-*** Cartridge Dimensions

b
3 Port 2 Port Port 1 Locating Shoulder

Nominal Capacity

Typical Cartridge Model Code DMDA ***

Cavity

c*** M,X,S D,L,T 132,8

Installation Torque (Nm) 45 - 50

45 L/min.+

T - 11A

35,0

22,2

108,2

37,3

***An additional 50,8 mm clearance is needed for coil installation and removal. + Only for A and N spools. View performance curves for other spool configurations.

Performance Curves DMDA-MA*


420 350 280 210 140 70 0

DMDA-MN*
420 350 280 210 1 to 2 and 140 2 to 1 70

DMDA-MB*
3 to 2
420 350 280 210 140 70 45 60 0 15

DMDA-SA*
350 250 150 100 50 30 45 60 0 10

DMDA-SN*
1 to 2
350 250 150 100 50 30 40 50 0

Valve Performance Limits at 10% Undervoltage and Stabilized Coil Temperature (See Sun website for DMDA-MP*, DMDA-MR*)
P = bar P = bar P = bar P = bar P = bar
1 to 2 2 to 1 2 to 3 3 to 2
15 30 45 60

2 to 3 1 to 2

2 to 1 3 to 2

2 to 3

3 to 2 2 to 1
10

1 to 2 2 to 3

2 to 3
0 15

Flow = L/min.

Flow = L/min.

30

Flow = L/min.

Flow = L/min.

20

Flow = L/min.

20

30

40

50

Pressure Differential vs. Flow (See Sun website for DMDA-MP*, DMDA-MR*)
20

P = bar

P = bar

P = bar

1 to 2

P = bar

3 to 2 2 to 1 1 to 2
0
10

10 5 0
10 20 30

10 5
20

10 5 0
10 20 30

1 to 2

10 5 0
10 20

1 to 2

P = bar

15

3 to 2

2 to 3

20 15

2 to 3

20 15

2 to 3

20 15

3 to 2 and 2 to 3

20 15 10 5 0
10

3 to 2 and 2 to 3 2 to 1 1 to 2

2 to 1

2 to 1

Flow = L/min.

40

50

Flow = L/min.

30

40

50

Flow = L/min.

40

50

Flow = L/min.

30

40

50

Flow = L/min.

20

30

40

50

I I I I I I I I I I I

Maximum operating pressure = 350 bar. Maximum valve leakage at 24 cSt = 80 cc/min. at 210 bar. Response time - typical = 50 ms. Manual override force requirement = 10 kg at 350 bar. Manual override stroke = 2,5 mm. Maximum switching frequency = 15000 cycles/hr. This valve is direct actuated and requires no minimum hydraulic pressure for operation. The solenoid tube assembly is fatigue rated for 350 bar service. Spools B and R are closed in the transition between their two positions. This results in a higher performance limit at the expense of lower capacity. When used as pilot controls, where capacity is not a factor, the closed transition will provide faster and more consistent response times. The soft shift feature results in significantly longer response time over Suns standard solenoid. Response time is dependant on flow, pressure, coil voltage, oil viscosity and ambient temperature. Typical response time ranges from 150 ms to 300 ms. A wide variety of coil termination and voltage options are available. See Sun website: Products: Accessories: Coils.

OPTION ORDERING INFORMATION

D MD A M
Nominal Capacity D 45 L/min. Control* M Manual Override X No Manual Override S Soft Shift D Twist/Lock, Dual, Manual Override L Twist/Lock, Detent, Manual Override T Twist/Lock, Momentary, Manual Override Spool Configuration** 2 A Normally Open Port 1 to 2, Closed 2 to 3 1 3 N Normally Open 2 Port 2 to 3, Closed 1 to 2 1 3 B Normally Open 2 Ports 1 to 2, Closed 2 to 3, Closed Transition 1 3 2 P Normally Open Ports 1 to 3, Closed 1 to 2 1 3 R Normally Open 2 Ports 2 to 3, Closed 1 to 2, 1 3 Closed Transition Coil Options** See page 187: Coil option information for Metal Housing (Round) Solenoid Cartridges. Seal Material N Buna-N V Viton

** Consult the Sun website for complete * See page 178 information on Spool Configurations, for information the full line of Coil Options and on Control Options Embedded Amplifier Coils/Controllers. Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products. 137
Intl Shortcut Catalogue #999-901-312

Solenoid Operated Cartridge Valves 4-WAY, 2-POSITION, DIRECTIONAL SPOOL VALVE


d
2 4

c
3 1

b
4 Port 3 Port 2 Port 1 Port

DNDA-***
Locating Shoulder

Cartridge Dimensions Nominal Capacity Typical Cartridge Model Code DNDA *** Cavity a b c*** X,M,S 40 L/min. T - 31A 84,8 22,2 89,4 D,L,T 114,3 37,3 45 - 50 d Installation Torque (Nm)

***An additional 50,8 mm clearance is needed for coil installation and removal.

Performance Curves DNDA-X** DNDA-SC* DNDA-SN* DNDA-***


Pressure Differential vs. Flow
20

Valve Performance Limits at 10% Undervoltage and Stabilized Coil Temperature


Note: Performance limits are derived with 4-way operation and symmetrical flow. For valve applications where either asymmetrical flow or 3-way operation are present, these performance limits may be reduced.
I I I I I I I I I I I
400 400 300 200 100 0 R, E, U, L (Spool Options) 5 300 200 100 0

P = bar

P = bar

2 to 3 1 to 4 4 to 1

P = bar

P = bar

Looped 3 to 2 to 4 to 1

400 300 200 100 0 5

1 to 2

15 10 5 0 10

2-1 Shifted, 3-4 Not Shifted

3-2 and 3-4 Shifted

3 to 2

2 to 1 4 to 3
10 15 20 25 30 35 40 45

3 to 4

2-1 Not Shifted 4-1 Shifted

D, H, Y

10 15 20 25 30 35 40 45

Flow = L/min.

10 15 20 25 30 35 40 45

Flow = L/min.

Flow = L/min.

Flow = L/min.

20

30

40

Maximum operating pressure = 350 bar. Maximum valve leakage at 24 cSt = 160 cc/min. at 210 bar. Manual override force requirement = 10 kg at 350 bar. Manual override stroke = 2,5 mm. Response time - typical = 50 ms. Maximum switching frequency = 15000 cycles/hr. Viscosity range = 10 - 600 cSt. This valve is direct actuated and requires no minimum hydraulic pressure for operation. The solenoid tube assembly is fatigue rated for 350 bar service. The soft shift feature results in significantly longer response time over Suns standard solenoid. Response time is dependant on flow, pressure, coil voltage, oil viscosity and ambient temperature. Typical response time ranges from 150 ms to 300 ms. A wide variety of coil termination and voltage options are available. See Sun website: Products: Accessories: Coils.

OPTION ORDERING INFORMATION

DNDA X
Nominal Capacity D 40 L/min. Control* X No Manual Override M Manual Override S Soft Shift D Twist/Lock Dual, Manual Override L Twist/Lock, Detent, Manual Override T Twist/Lock, Momentary, Manual Override * See page 178 for information on Control Options Spool Configuration** C Closed, Shift to Through D Closed, Shift to Cross E Cross, Shift to Closed H Open, Shift to Cross L Cross, Shift P to A, B and T Blocked
2 4

Spool Configuration** N Through, Shift to Cross R Regen, Shift to Cross T Tandem, Shift to Through U Through, Shift to Through Y Motor, Shift to Cross
2 4

Coil Options** See page 187: Coil option information for Metal Housing (Round) Solenoid Cartridges.

3 2

1 4

3 2

1 4

3 2

1 4

3 2

1 4

3 2

1 4

3 2

1 4

3 2

1 4

3 2

1 4

Seal Material
3 1

N Buna-N V Viton

** Consult the Sun website for complete information on Spool Configurations, the full line of Coil Options and Embedded Amplifier Coils/Controllers.

Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products.
Intl Shortcut Catalogue #999-901-312

138

Solenoid Operated Cartridge Valves 4-WAY, 3-POSITION, SPRING CENTRED, DIRECTIONAL SPOOL VALVE
d
2 4

Coil A

Coil B

3 1 DNDC-XAN

b
4 Port 3 Port 2 Port

Locating Shoulder

Cartridge Dimensions Nominal Capacity Typical Cartridge Model Code DNDC X** Cavity T - 31A a 84,8 b 22,2 c*** 139,4 d 37,3 Installation Torque (Nm) 45 - 50

20 L/min.

***An additional 50,8 mm clearance is needed for coil installation and removal.
1 Port

Performance Curves DNDC-X**


Valve Performance Limits at 10% Undervoltage and Stabilized Coil Temperature
400 8

Pressure Differential vs. Flow


15

3 to 1 H and T Spools 4 to 1 3 to 2 3 to 4 2 to 1
0

P = bar

P = bar

P = bar

300 200 100 0 5

T C,W

6 4 2 0 5 10 15 20

4 to 1 3 to 2 3 to 4 2 to 1

10 5

Flow = L/min.

15

25

35

45

Flow = L/min.

Flow = L/min.

10

20

30

I I I I I I I I

Maximum operating pressure = 350 bar. Maximum valve leakage at 24 cSt = 160 cc/min. at 210 bar. Response time - typical = 50 ms. Maximum switching frequency = 15000 cycles/hr. Viscosity range = 10 - 600 cSt. This valve is direct actuated and requires no minimum hydraulic pressure for operation. The solenoid tube assembly is fatigue rated for 350 bar service. A wide variety of coil termination and voltage options are available. See Sun website: Products: Accessories: Coils.

OPTION ORDERING INFORMATION

DNDC X
Nominal Capacity D 20 L/min. Control* X No Manual Override Spool Configuration** A A to T Centre
Coil A

Spool Configuration** R Regen Centre


Coil B Coil A

Coil Options**
4

B B to T Centre
Coil A

3 2

1 4

T Tandem Centre
Coil B Coil A

3 2

1 4

Coil B

See page 187: Coil option information for Metal Housing (Round) Solenoid Cartridges.

C Blocked Centre
Coil A

3 2

1 4

W A and B, Bleed to T Centre


Coil B Coil A

3 2

1 4

Coil B

3 2

1 4

3 2

1 4

Coil B

H Open Centre
Coil A

Coil B

Y A and B to T Centre

Coil A

Coil B

Sea Material N Buna-N V Viton * See page 178 for information on Control Options ** Consult the Sun website for complete information on Spool Configurations, the full line of Coil Options and Embedded Amplifier Coils/Controllers.

Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products.
Intl Shortcut Catalogue #999-901-312

139

NOTES

140

Intl Shortcut Catalogue #999-901-312

You might also like