You are on page 1of 4

JCI

JC INTERNATIONAL LIMITED RC413243

Customer: Transocean Support Service

OMOYIBO PATRICK

NDT INSPECTION ENGINEER:

Project Job: Baltic 1


ADDRESS:
Project:
Upgrade
Location:
Rig Floor

Equipment Type: Cygnus 4 Serial No: 1404


Calibration Block: 0.59" Cylindrical Test Block
Couplant:
Ultra Gel
Material:
Carbon steel
System: Choke Manifolds

Type of Inspection: Ultrasonic Thickness Gauging


Surface Condition: Coated
Test Standard:
BS EN 583-1

Date:
Procedure Ref:

Gain: 6 dbs

12/N

9/W

3/E

6/S

16/08/11
JOP-060
REFERENCES:
DRAWINGS NO

01

ULTRASONIC THNICKNESS MEASUREMENT/EVALUATIONS REPORTS


Test
Point

Item

Diameter

Minimum Wall Thickness


(inches)
3/E

6/S

9/W

Average

Original Wall Thickness


(mm)

12/N
COMPONENT:

1
2
3
4
6
7
8
9
10
11
12
13
14
15
16
17
18
19

P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
B
P

5 1/2"
5 1/2"
5 1/2"
5 1/2"
5 1/2"
5 1/2"
5 1/2"
5 1/2"
5 1/2"
5 1/2"
6"
6"
5 1/2"
5 1/2"
5 1/2"
5 1/2"
6"
6"

0.73
0.69
0.68
0.53
0.70
0.77
0.40
0.70
0.69
1.20
1.33
1.39
1.23
1.22
1.21
1.23
1.39
1.39

0.73
0.69
0.69
0.54
0.69
0.69
0.45
0.70
0.69
1.20
1.35
1.39
1.23
1.23
1.21
1.23
1.40
1.38

0.73
0.69
0.68
0.53
0.75
0.75
0.45
0.75
0.69
1.95
1.35
1.40
1.23
1.23
1.22
1.22
1.39
1.39

Diminution (mm)

0.73
0.69
0.69
0.54
0.70
0.77
0.40
0.70
0.69
1.20
1.33
1.39
1.23
1.23
1.21
1.23
1.39
1.39

0.73
0.69
0.68
0.53
0.71
0.74
0.43
0.71
0.69
1.39
1.34
1.39
1.23
1.23
1.21
1.22
1.39
1.39

CHOKE MANIFOLD

% Dimimum

Minimum
Allowable

Comment

20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65

P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P

5 1/2"
6"
6"
6"
5 1/2"
6"
6"
6"
6"
5 1/2"
6"
6"
5 1/2"
6"
6"
6"
6"
5 1/2"
6"
6"
6"
6"
5 1/2"
5 1/2"
6"
6"
6"
5 1/2"
6"
6"
6"
6"
5 1/2"
5 1/2"
6"
5 1/2"
5 1/2"
6"
6"
6"
6"
5 1/2"
6"
6"
5 1/2"
5 1/2"

1.22
1.39
1.38
1.38
1.20
1.38
1.38
1.38
1.36
1.20
1.39
1.37
1.21
1.44
1.42
1.44
1.90
1.22
1.40
1.39
1.40
1.39
1.19
1.20
1.46
1.40
1.40
1.23
1.38
1.38
1.42
1.45
1.22
1.22
1.28
1.22
1.21
1.40
1.39
1.39
1.30
1.20
1.40
1.39
1.26
0.95

1.21
1.39
1.37
1.37
1.19
1.37
1.37
1.37
1.38
1.19
1.37
1.37
1.21
1.44
1.42
1.45
1.92
1.22
1.42
1.40
1.40
1.39
1.19
1.23
1.46
1.40
1.41
1.23
1.38
1.39
1.42
1.45
1.22
0.70
1.28
1.22
1.21
1.43
1.40
1.40
1.32
1.22
1.40
1.39
1.27
0.95

1.20
1.40
1.39
1.39
1.20
1.39
1.39
1.39
1.38
1.20
1.39
1.38
1.20
1.44
1.42
1.44
1.91
1.23
1.41
1.39
1.41
1.39
1.20
1.21
1.47
1.42
1.42
1.24
1.39
1.38
1.43
1.46
1.23
0.69
1.29
1.23
1.22
1.42
1.39
1.40
1.31
1.20
1.42
1.40
1.26
0.95

1.22
1.39
1.38
1.38
1.19
1.38
1.38
1.38
1.39
1.19
1.38
1.39
1.21
1.44
1.42
1.45
1.90
1.22
1.40
1.40
1.40
1.40
1.20
1.22
1.46
1.41
1.42
1.23
1.39
1.39
1.42
1.45
1.23
0.68
1.28
1.22
1.22
1.41
1.39
1.40
1.30
1.21
1.40
1.39
1.27
0.95

1.21
1.39
1.38
1.38
1.19
1.38
1.38
1.38
1.38
1.19
1.38
1.38
1.21
1.44
1.42
1.45
1.91
1.22
1.41
1.40
1.40
1.39
1.19
1.22
1.46
1.41
1.41
1.23
1.39
1.39
1.42
1.45
1.23
0.82
1.28
1.22
1.22
1.42
1.39
1.40
1.31
1.21
1.40
1.39
1.27
0.95

66
67
68
69
70

71
72

73
74

75
76

P
P
P
P
EL(A)
B
C
P
TEE (A)
B
C
P
EL(A)
B
C
P
P

6"
6"
6"
6"
5 1/2"
5 1/2"
5 1/2"
5 1/2"
6"
6"
6"
5 1/2"
5 1/2"
5 1/2"
5 1/2"
6"
6"

TEE
P
EL
RED

TEE JOINT
PIPE
ELBOW
REDUCER

Names of NDT Engineer:

1.39
1.40
1.49
1.48
1.22
1.24
1.25
0.68
1.35
1.35
1.39
0.70
1.26
1.23
1.24
1.46
1.45

1.41
1.39
1.49
1.48
1.23
1.22
1.24
0.69
1.35
1.35
1.39
0.69
1.30
1.21
1.22
1.47
1.45

1.40
1.41
1.49
1.49
1.22
1.22
1.24
0.68
1.35
1.35
1.39
0.71
1.26
1.22
1.23
1.46
1.47
N/A
N/R

1.39
1.40
1.50
1.48
1.22
1.22
1.24
0.68
1.40
1.40
1.39
0.70
1.26
1.21
1.22
1.46
1.45

1.40
1.40
1.49
1.48
1.22
1.23
1.24
0.68
1.36
1.36
1.39
0.70
1.27
1.22
1.23
1.46
1.46
DENOTATIONS
NOT APPLICABLE
NO READING

OMOYIBO PATRICK

SNT LEVEL II MT, PT & UT & FID Boilers & Pressure Vessels

COMMENT:
Names of NDT Engineer: OMOYIBO PATRICK

SNT LEVEL II MT, PT & UT & FID Boilers & Pressure Vessels

JCI

JC International Limited

Customer: Transocean

RC 413243

OMOYIBO PATRICK

NDT INSPECTION ENGINEER:

Project Job: Baltic 1

Equipment Type: Cygnus 4 Serial No: 1404

ADDRESS:
Project:
Upgrade
Location: Rig Floor Area

Calibration Block: 0.594" Cylindrical Test Block


Couplant:
Ultra Gel
Material:
Carbon steel

Gain: 6 dbs

12/N

3/E

9/W

System: Degasser Tank


Type of Inspection: Ultrasonic Thickness Gauging
Surface Condition: Coated
Test Standard:
BS EN 583-1

Date:
Procedure Ref:

6/S

16/08/11
JOP-060

DRAWINGS NO

ISO # 01

ULTRASONIC THNICKNESS MEASUREMENT/EVALUATIONS REPORTS

Test
Point

Minimum Wall Thickness


Item

(mm)

Average

Diameter
NW

9/W

SW

6/S

SE

3/E

NE

Original Wall
Thickness (mm)

Diminution (mm) % Dimimum

Minimum
Allowable

COMPONENT: DEGASSER TANK


77

78
79
80
81
82
83
84
85
86
87

Tank A
B
C
D
Tank
Tank
Tank
Tank
Tank
Tank
Tank
Tank
Tank
Tank A
B
C
D

0.63
0.62
0.62
0.62
0.50
5.00
0.50
0.50
0.50
0.49
0.50
0.50
0.50

0.63
0.62
0.62
0.62
0.49
0.50
0.50
0.50
0.50
0.49
0.50
0.49
0.50

0.62
0.62
0.62
0.62
0.49
0.50
0.50
0.49
0.50
0.48
0.50
0.49
0.50

0.62
0.62
0.62
0.62
0.50
0.50
0.49
0.50
0.50
0.49
0.50
0.50
0.50

0.61
0.62
0.62
0.62
0.50
0.49
0.50
0.50
0.49
0.50
0.50
0.50
0.50

0.62
0.62
0.62
0.62
0.49
0.50
0.50
0.50
0.49
0.50
0.49
0.50
0.50

0.62
0.62
0.62
0.62
0.49
0.50
0.50
0.49
0.49
0.50
0.49
0.50
0.49

0.62
0.62
0.62
0.62
0.50
0.50
0.49
0.50
0.50
0.49
0.49
0.50
0.50

0.62
0.62
0.62
0.62
0.49
1.06
0.49
0.50
0.49
0.49
0.49
0.50
0.50

NO ACCESS

COMMENT:
Names of NDT Engineer:

OMOYIBO PATRICK

SNT LEVEL II MT, PT & UT & FID Boilers & Pressure Vessels

Comment