P

N
On-Line Quality Power Extended Batteries

Liebert

T HE M OST V ERSATILE UPS A VAILABLE F OR C OMPUTER AND T ELECOMMUNICATIONS N ETWORK A PPLICATIONS


UPStation GXT

Multi-Module Option

.........

AND

NETWORK COMPONENTS SUCH AS ROUTERS, HUBS, GATEWAYS BRIDGES TELECOMMUNICATIONS SYSTEMS, VOICEMAIL AND E-MAIL SYSTEMS TEST AND DIAGNOSTIC EQUIPMENT NETWORK SERVERS OTHER CRITICAL ELECTRONIC EQUIPMENT

ISO 9000 CERTIFIED COMPANY

N OT A LL UPS S YSTEMS A RE C REATED E QUAL


..........
Critical computer and telecommunication systems demand the highest level of power protection. You simply cant afford to put them at risk with a UPS system you cant trust in every situation. Power problems such as surges or sags, harmonics, brownouts and blackouts are hard on computers and network components. They cause scrambled and lost data, interrupted communications, system crashes... even equipment damage. It all adds up to lost time and productivity. But the fact is - not all UPS systems are designed to handle all of these problems. This poses a serious problem if you are using your network for critical corporate activities, because buying the right UPS is very important to the long-term health of your organization. It is more important than ever to find a UPS solution that is equipped to handle virtually any power problem. It means finding a system that fits inand communicates withthe equipment it is protecting. And above all, it means selecting a UPS that can handle a wide range of power inputs and still supply clean, precise power for your vital systems.
PROBLEM
Power surges, sags, brownouts, noise

L IEBERT UPS TATION GXT P ROVIDES T RUE O N -L INE P OWER F OR Y OUR C RITICAL S YSTEMS
.......
The answer is the Liebert UPStation GXTthe affordable on-line UPS from the company that began the computer protection industry over 30 years ago. UPStation GXT is designed with the features you need to protect mission-critical equipment from a variety of power problems: True On-Line Design. Protection Against All Power Threats. Internal SNMP Communication. Extended Battery Options. Two-Year Warranty. N+1 Redundancy Options.

RESULT
Corrupted and lost data, disc and system crashes, equipment damage Data destruction or loss, equipment & system damage Data destruction or loss, equipment & system damage, productivity loss

PROTECTION
On-Line UPS with power conditioning

Normal blackouts (98% last less than 2 minutes) Extended blackouts

UPS with instant, multiple-source switching capability UPS with extended battery capability, & generator power conditioning UPS with built-in network communications

DYNAMIC BYPASS

UTILITY

SURGE SUPPRESSION

POWER FACTOR CORRECTION/RECTIFIER/ CHARGER

INVERTER

LOAD

Complex network management/ shutdown

Loss of transmitted data, partial or total network crashes, productivity loss

BATTERY

A maze of conflicting product claims

Under-protected with the same set of problems as before; over-spent to get useless features or capacity

UPS configuration help; on-site support

2
Call Your Local VAR Representative or 1-800-877-9222

The UPStation GXT will transfer the critical load to utility power in the event of adverse conditions within the UPS. This adds an extra measure of reliability and availability to the supported equipment. And no additional cabinets are required.

UPStation GXT is available in mini-tower and rack/tower convertible models, as well as a Multi Module redundant system.

Flexible Battery Back-Up. Lieberts rapid recharge system helps override multiple outages with its quick recovery. Additional battery capacity can extend your blackout override period. By matching load size, back-up time and communications capability, Liebert can protect virtually any class of mission-critical equipment. Communications for Power Monitoring and Control. The UPStation GXT offers a variety of UPS communications, including SNMP-based options, to provide the monitoring capabilities demanded by todays network computing systems. N+1 Redundancy Options. To protect your most critical applications, the UPStation GXT Multi Module system provides N+1 redundancy capability. Warranty Support You Can Count On. Lieberts standard two-year warranty ensures repair or replacement of your UPS if it experiences problems during the warranty period. Liebert will ship a replacement unitrather than return and repair your original unitin order to get your system power back on-line as soon as possible. On-site repair services are also available. $25,000 Product Production Promise. Liebert will provide repair costs or reimbursement up to $25,000 if your UPStation GXT fails to protect your connected equipment from damage caused by incoming AC power line transfers. Ongoing Technical Support. We provide you with technical support for as long as you own a Liebert UPS. A call to 1-800-222-5877 puts you in touch with an experienced UPS specialist. (614-841-6755 outside the U.S.)

The Ability To Handle A Wide Range Of Power Input. In order to grow with your network, a UPS must be able to deal with different types of power input, including imperfect power from your electric utility, DC power from batteries, the variable output of most standby generators, and harmonics from inside the building or even from your own network equipment. The on-line UPStation GXT is designed to handle these situations. If a UPS cant provide proper protection under these conditions, then it isnt providing complete protection. Sophisticated Protection in an Easy-To-Use Package. The UPStation GXT is easy to install...easy to set up...and even easier to use. It features simple operation with a single switch for uncomplicated, error-free start up. A front-mounted panel displays system status, load levels, battery time remaining and any alarm conditions. It also shows an indication and diagnosis of UPS fault conditions, as well as building wiring faults. For maximum flexibility, the UPStation GXT can be easily installed as a space-saving, rackmounted unit or as a compact freestanding tower. This versatility allows it to be used to protect networks, servers, telecommunications equipment or industrial process equipment just about anywhere.

The Details: Power Quality Battery Back-Up

UPS TATION GXT P ROVIDES Q UALITY P OWER , R EGARDLESS O F I NPUT Q UALITY


Unlike other UPS technologies, the UPStation GXTs on-line design eliminates all these potential power problems: Power spikes and transients. Special surge protection capability exceeds IEEE 587 Category A. EMI/RFI noise reduction. Full-time EMI/RFI filtering improves computer performance and helps eliminate minor data corruption and noise-induced glitches that generate most problems. Additional EMI noise attenuation is provided by the UPStation GXTs combination of a steel cabinet and internal ferrite beads that acts as a double-shield against electromagnetic interference transmitted along power cables and through the cabinet. Voltage sags and brownout conditions. UPStation GXT has one of the widest input voltage ranges available, so minor low voltage conditions are corrected without resorting to battery operation. The input voltage is variable, based upon output load levels. These may drop as much as 50% below normal before transfer to back-up, reducing the number of battery discharges and extending service life. Harmonics. A special category of noise that causes waveform distortion, harmonics can be triggered by problems hundreds of miles away or as near as the next piece of equipment on the network. Because they are difficult to find and correct, harmonics are best reduced at the UPS. Not all UPS systems can do that - the UPStation GXT can. Power factor corrected loads. Computer equipment can cause voltage oscillations and adversely affect devices throughout the network. This includes ferroresonant-type power protection systems which can actually contribute to this problem. The UPStation GXT maintains stable voltage output even with the power-factor corrected loads typical of modern computer equipment. Outages. With the zero transfer time offered by on-line technology, flexible battery configurations and the ability to handle generator-produced power, your network wont even blink during an extended outage.
NETWORK EQUIPMENT

..........
Computer and peripheral manufacturers specify the power tolerance for their equipment...and its in a very tight range. Go outside those limits and they warn that performance will degrade, equipment life could be shortened or damage could occur - perhaps even voiding the warranty. Electric utilities, however, provide a level of power quality that is adequate for household and large industrial use...but not good enough for todays sensitive electronic equipment. The Liebert UPStation GXT is a true on-line power source, so whatever the quality of power coming in - the pure sinewave output meets the exacting standards of your equipment.

Unlike most network UPS systems, Liebert UPStation GXT can handle all the variations in utility power, as well as the significantly varying frequencies associated with generator start-up/warm-up and load changes.

UPStation GXTs standard batteries provide 6-10 minutes of back-up power, allowing your system to ride out 98% of all power outages. Additional battery modules can extend battery back-up to 60 minutes at full load. A years worth of utility power typically includes dozens of sags brownouts, and a handful of spikes, surges and brief outages. None pose a problem for the UPStation GXT. TELECOMMUNICATION Equipment in the network can create harmonics that affect power to other nearby network components...unless theyre plugged into a Liebert UPStation GXT.

4
Call Your Local VAR Representative or 1-800-877-9222

CRITICAL-STAND-ALONE

F LEXIBLE B ATTERY B ACK -U P M AXIMUM U PTIME O PTIONS


..........
The UPStation GXT features unexcelled battery flexibility and upgrade capability. It can be configured according to your site needs and type of application. The standard UPStation GXT provides six to ten minutes of back-up power at full load. Thats longer than 98% of all power outages and enough time to shut down critical operations in an orderly fashion. Zero Transfer Time. When utility power fails, your critical load remains supported by a seamless flow of power from the UPStation GXT. True on-line design means zero transfer time from external to internal power. Maintenance-Free, Hot-Swappable Batteries. The UPStation GXT uses sealed, valve-regulated, lead-acid batteries, to provide long, trouble-free service life. And when batteries do need to be replaced, they are hot-swappable, allowing you to quickly and easily change batteries without shutting down the system. Add-On Battery Cabinets. Want more time? Additional battery modules can be added by plugging in the cable from the new battery into the UPS. Add one or two cabinets as your needs change. Battery cabinets are available for UPStation GXT rack/tower models only. Micro POD Output Distribution and Maintenance Bypass Module. When your computer system cant be without power, even for scheduled UPS maintenance, a Liebert Micro POD (Power Output Distribution) ensures continuous uptime. It allows you to manually transfer connected equipment to utility power via a maintenance bypass switch, permitting scheduled maintenance or UPS replacement without power disruption.
TM

AND

Protected Devices

Micro POD plugs into UPS outlet

To Utility

Micro POD UPS plugs into Micro POD

User replaceable, hot-swappable batteries allow you to easily replace the internal battery, without shutting down your connected equipment.

The Details: Absolute Reliability N+1 Redundancy

L IEBERT UPS TATION GXT M ULTI M ODULE : M AXIMUM U PTIME F OR C RITICAL N ETWORKS
IntelliPOD #3 Room for expansion UPS #3

.........
When your uptime is not negotiable, you need the reliability of a redundant power system. Liebert offers the proven reliability of the UPStation GXT in a redundant configuration designed to fit the changing needs of networks and other growing systems. The N+1 design provides a back-up module to sustain power to your critical equipment in the event of a UPS module failure, or during UPS maintenance. This design ensures continuous power to the equipment your business depends on. The rackmounted UPStation GXT Multi Module is available as a pre-built system, or can be field-upgraded with an existing GXT model when your needs change. The UPStation GXT Multi Module system offers a variety of advantages: N+1 Redundancy. The Multi Module system is made up of the highly reliable UPStation GXT on-line UPS - a field-proven solution with thousands of hours of operation. Compatible with existing UPStation GXT 3 kVA units and SiteNet SNMP Manager software. Scalable system is expandable in 3 kVA increments up to 9 kVA. Integrated IntelliPODTM power output distribution units provide a maintenance-bypass function as well as UPS monitoring. Hot-swappable communications allow adding or changing Intellislot SNMP module without shutting down the load. Hot-swappable, user-replaceable batteries maintain conditioned power to the load during battery change-out.
GXT Multi Module
Rack Size Half Height Cabinet Full Height Cabinet Weight lb. (kg) Half Height Full Height 19 19 3 kVA Redundant System 392(178) 437(198)
(Currently Available in 120V & 230V Applications)

IntelliPOD #1

UPS #1

IntelliPOD #2

UPS #2 Redundant POD

Redundant UPS Input Power Module

UPStation GXT Multi Module allows you to configure a redundant power solution to protect electronic equipment nowand to upgrade for additional capacity in the future. The system can be upgraded in 3 kVA increments for 3 kVA, 6 kVA or 9 kVA power protection with a 3 kVA back-up module. (6 kVA N+1 configuration shown in half-height cabinet)

Normal Height 56 78

Normal Depth 30 30

Internal height Rack Unit (in/mm) 29U 42U 51.5(1308) 73.5(1865)

6 kVA Redundant System 508(230) 553(251)

9 kVA Redundant System 624(283) 669(303)

6
Call Your Local VAR Representative or 1-800-877-9222

M AKE UPS TATION GXT A N I NTELLIGENT P ERIPHERAL W ITH C OMMUNICATION O PTIONS


..........
The UPStation GXT provides the communications capability and flexibility that is vital to the continuous operation of todays more complex distributed computing systems.

The Details: Communications For Power Monitoring and Control

.......

SNMP HARDWARE OPTIONS


IntellislotTM. The UPStation GXT is the only UPS in its class to offer internal SNMP, providing communications simplicity not available in an external SNMP device. This allows monitoring and control of all network devices in a consistent manner. Internal SNMP installation also saves space, enhances reliability, and is internally protected by the UPS. This is an invaluable monitoring and control system for networks operating on this industry standard. SiteNet Integrator External SNMP and Load Control Module. For extended monitoring capability of other critical systems via SNMP, consider the Liebert SiteNet Integrator. With the Integrator, you can monitor anything that has a digital output: UPS, air conditioners, water and smoke detectors, thermostats, secure doors. And, like the UPStation GXT, you can specify the Integrator in either rackmount or desktop configurations. The optional Load Control Module (LCM) provides remote power management of up to six pieces of connected equipment. With the LCM, you can cycle power to reboot equipment or turn off connected systems by direct control, or shut down based on pre-set alarm conditions.

MultiPort4.

.......
SITENET SOFTWARE KEEPS YOU INFORMED AND IN CONTROL OF UPS STATUS
SiteNet SNMP Manager. UPS monitoring software for Network Management Systems is a series of snap-in screens for your NMS software. This easy-to-use software seamlessly incorporates Liebert UPS into your network and provides user-friendly monitoring and control of power. SiteNet 1. UPS monitoring and shutdown software prevents unexpected server shutdowns by automatically monitoring UPS activity and closing down protected nodes if utility power remains off. When used in conjunction with SiteNet 1, the external SiteNet MultiPort multiplexer communicates the status of a single UPS to as many as eight PCs, servers or workstations. When installed in the UPStation GXT Intellislot, the MultiPort4 allows communication to up to four PCs, servers or workstations. SiteNet 2. Power surveillance and shutdown management software provides ongoing monitoring and controlvia a two-way graphical interface between network servers and system UPS.

SiteNet Integrator and LCM.

Intellislot SNMP cards allow remote monitoring and control of the UPS.

For more information, request the Liebert SiteNet Communications brochure.

Keeping Business in Business

Liebert

.......
UPStation GXT SPECIFICATIONS
UPStation GXT120 VAC Models, 60 Hz Mini Tower Models Rack/Tower Models
Model No. GXT700MT-120 700/490 GXT1000MT-120 1000/700 GXT1000RT-120 GXT1000RTE-120 GXT1500RT-120 1000/700 1000/700 1500/1050 120 VAC nominal; variable based upon output load 80-83 VAC to 134-138 VAC 80-83 VAC to 134-138 VAC 70-73 VAC to 134-138 VAC 60-62VAC to 134-138 VAC NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-15P 120 VA, +/-3%; sinewave (6)NEMA 5-15R (4)NEMA 5-15R Battery Time (FL/HL) Dimensions: in. (mm) WxDxH Weight: lbs. (kg) 5 min./16 min. 6.4 x 16.9 x 8.9 (162 x 430 x 225) 29.9 (13.6) (4)NEMA 5-15R 7 min./19 min. 6.4 x 16.9 x 8.9 (162 x 430 x 225) 36.5 (16.6) (8)NEMA 5-15R 7 min./19 min. (8)NEMA 5-15R 18 min./50 min. (8)NEMA 5-15R 5 min./15 min. (2)NEMA 5-20R 11 min./27 min. (6)NEMA 5-15R (1)NEMA L5-30R 6 min./15 min. 7.0 x 20.6 x 16.9 91.7 (41.6) 90-93 VAC to 134-138 VAC 80-83 VAC to 134-138 VAC 70-73 VAC to 134-138 VAC 60-62 VAC to 134-138 VAC NEMA 5-20P NEMA L5-30P GXT2000RT-120 2000/1400 GXT3000RT-120 3000/2100

.........
LIEBERT CORPORATION
1050 DEARBORN DRIVE P.O. BOX 29186 COLUMBUS, OHIO 43229 800.877.9222 PHONE (U.S. & CANADA ONLY) 614.888.0246 PHONE 614.841.6022 FAX upstech@liebert.com EMAIL GLOBE PARK MARLOW BUCKINGHAMSHIRE SL7 1YG UNITED KINGDOM +44 1628 403200 PHONE +44 1628 403203 FAX 19/F, CAUSEWAY BAY PLAZA 1 489 HENNESSY ROAD CAUSEWAY BAY HONG KONG 852 2 572 2201 PHONE 852 2 831 0114 FAX

VA/Watts (max.) Input Voltage Range 100-90% Loading 90-70% Loading 70-30% Loading 30-0% Loading Input Plug Output Voltage Output Receptacles

7.0 x 20.6 x 16.9 7.0 x 20.6 x 16.9 7.0 x 20.6 x 16.9 7.0 x 20.6 x 16.9 57.3 (26.0) 73.1 (33.2) 64.1 (29.1) 86.6 (39.3)

(177 x 522 x 430) (177 x 522 x 430) (177 x 522 x 430) (177 x 522 x 430) (177 x 522 x 430)

UPStation GXT230 VAC Models, 50 Hz Mini Tower Models Rack/Tower Models


Model No. VA/Watts(max.) Input Voltage Range 100-90% Loading 90-70% Loading 70-30% Loading 30-0% Loading Input Socket Output Voltage Output Receptacles (4)IEC320-10A Battery Time (FL/HL) WxDxH 6 min./18 min. (6.4 x 16.9 x 8.9) 13.6 (29.9) Dimensions: mm (in.) 162 x 430 x 225 Weight: kg (lbs.) (4)IEC320-10A 6 min./18 min. 162 x 430 x 225 (6.4 x 16.9 x 8.9) 16.6 (36.5) (4)IEC320-10A 6 min./18 min. 177 x 522 x 430 26.0 (57.3) (4)IEC320-10A 17 min./49 min. 177 x 522 x 430 33.2 (73.1) (4)IEC320-10A 5 min./15 min. 177 x 522 x 430 29.1 (64.1) (4)IEC320-10A 11 min./27 min. 177 x 522 x 430 39.3 (86.6) IEC320-10A GXT700MT-230 700/490 GXT1000MT-230 1000/700 GXT1000RT-230 GXT1000RTE-230 GXT1500RT-230 GXT2000RT-230 1000/700 1000/700 1500/1050 2000/1400 230 V AC nominal; variable based upon output load 160-163 VAC to 273-276 VAC 160-163 VAC to 273-276 VAC 140-143 VAC to 273-276 VAC 120-122VAC to 273-276 VAC IEC320-10A IEC320-10A IEC320-10A IEC320-10A 230 VA, +/-3%; sinewave (4)IEC320-10A (1)IEC320-16A 6 min./15 min. 177 x 522 x 430 (7.0 x 20.6 x 16.9) 41.6 (91.7) 184-187 VAC to 273-276 VAC 160-163 VAC to 273-276VAC 140-143 VAC to 273-276 VAC 120-122 VAC to 273-276 VAC IEC320-10A IEC320-16A GXT3000RT-230 3000/2100

.........
LIEBERT WEB SITE
http://www.liebert.com

(7.0 x 20.6 x 16.9) (7.0 x 20.6 x 16.9) (7.0 x 20.6 x 16.9) (7.0 x 20.6 x 16.9)

.........
7
X

UPStation GXT208 VAC Models Rack/Tower Models


Model No. VA/Watts(max.)* Input Voltage Range 100-90% Loading 90-70% Loading 70-30% Loading 30-0% Loading Input Socket Output Voltage* Output Receptacles (2) NEMA L6-15R Battery Time (FL/HL) Dimensions: mm (in.) WxDxH Weight: kg (lbs.) 11 min./27 min. 177 x 522 x 430 (7.0 x 20.6 x 16.9) 39.3 (86.6) GXT1800RT-208 1800/1260 GXT2700RT-208 2700/1890 184-187 VAC to 273-276 VAC 160-163 VAC to 273-276 VAC 140-143 VAC to 273-276 VAC 120-122VAC to 273-276 VAC NEMA L6-15P NEMA L6-20P 208 VA, +/-3%; sinewave (2) NEMA L6-15R (1) NEMA L6-20R 6 min./15 min. 177 x 522 x 430 (7.0 x 20.6 x 16.9) 41.6 (91.7) (2) NEMA L6-15R 11 min./27 min. 177 x 522 x 430 (7.0 x 20.6 x 16.9) 39.3 (86.6) GXT1800RT-208* 2000/1400 GXT2700RT-208* 3000/2100 184-187 VAC to 273-276 VAC 160-163 VAC to 273-276VAC 140-143 VAC to 273-276 VAC 120-122 VAC to 273-276 VAC NEMA L6-15P NEMA L6-20P 240 VA, +/-3%; sinewave (2) NEMA L6-15R (1) NEMA L6-20R 6 min./15 min. 177 x 522 x 430 (7.0 x 20.6 x 16.9) 41.6 (91.7)

24 TECH SUPPORT

800 222 5877 PHONE 614 841 6755 (OUTSIDE USA)

208 VAC nominal; variable based upon output load

240 VAC nominal; variable based upon output load

LIEBERT NETWORK PROTECTION PRODUCTS ARE AVAILABLE FROM:

* Note the output voltage is user selectable between 208, 220, 230 and 240 VAC. For extended battery run times, consult your Liebert VAR or representative.

While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 1998 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. Liebert and the Liebert logo are registered trademarks of the Liebert Corporation. Keeping Business in Business is a registered trademark of the Liebert Corporation. SL-23420 (R11/98) Printed in USA