You are on page 1of 3

Parameter

Input frequency/voltage fluctuation Output Voltage Output current range Overload capacity Output frequency Efficiency Frequency resolution Control mode Acceleration/deceleration time Digital I/O Communication protocols Controls Power Supply Transformer PID function Control function Operation mode Frequency setting Status output of VFD Environment Operating temperature Operating humidity 20% 400V

Specs
380 - 460 V 400 V @ 50 hz

Rockwell Liquiflo I

300A - 1400A 200% of rated current for 60 seconds per 10minutes; 150% of rated current for 3s; 0.5 - 50Hz 96% 0.01Hz Volts/Hertz, Vector Control, Sensorless Vector 0 to 3200s, Adjustable 5/5 channels digital inputs/outputs RS485, Modbus, TCP/IP, DeviceNet, GPRS wireless transmission Single phase 110 VAC, Capacity: 3kVA Embedded PID regulator Start only by command from Chiller panel Remote via chiller controller via 0-10VDC analog inputs

4 Frames, 414A/500A/643A/1157A

1 to 50 hz > 0.95 1 hz Volts/Hertz No Information available Yes RS485 Yes Yes Yes Yes Yes

Analog output and digital output Yes Suitable for Indoor Installation where RH could be upto Yes 95% 0 - 50 C 0 - 55 without derating 0 to 95%, no condensing Overcurrent, Short circuit, Earth fault, Overvoltage, Low voltage, Overload, Overheat, Phase loss, Low DC Bus Voltage, High DC Bus Voltage, High Internal Ambient temperature IP 54 Air cooling/Liquid cooled Compliant with IEEE 519 Liquid cooled THD current upto 25% Fit in Standard Wye Delta Panel No 0 minutes 2 minutes DC choke No Ideally rear clearance and access in required for service. But not provided Yes Overcurrent, Short circuit, Earth fault, Overvoltage, Low voltage, Overload, Overheat, Phase loss, Low DC Bus Voltage, High DC Bus Voltage,

Protection

IP Rating Cooling Harmonics Size (w x h x d) Bypass Start Available Time between Starts DC Choke/ AC Choke Local Service Clearance around drive Price Warranty

VFD Comparison
Fuji
380 - 480V ( - 15% to +10%) 400V @ 50 hz 28 Frames from 2.5A to 1040A 120% for 1 minute 0.0 to 50 hz > 0.95 0.1 hz Volts/Herts 1 to 3600s Yes Modbus RTU To be specified when ordering Yes Yes Yes Yes Yes Yes 0 - 50 without derating 380 - 480 V 400V @ 50 hz 35 Frames from 1.6A to 1530A 150% for 1 minute 0.1 to 50 hz 98% 0.1 hz Volts/Hertz 1 to 3600s Yes RS 485, Modbus To be specified when ordering Yes Yes Yes Yes Yes Yes 0- 45 without derating

Danfoss
360 - 480 V 400V @ 50 hz 75 frame 2.3A 1188A 150% for 1 minute 0.1 to 50Hz > 0.95 0.1 hz Volts/Hertz 1 to 3200s Yes

Schneider

Modbus, Lonwork, Bacnet To be specified when ordering Yes Yes Yes Yes Yes Yes 0 - 40 without derating Yes

Yes Yes Overcurrent, Short circuit, Earth fault, Overvoltage, Low voltage, Overload, Overheat, Phase loss, Low DC Bus Not received Voltage, High DC Bus Voltage, Single Phase, Output Phase loss, Stall Prevention, Surge Protection, Motor Overload Early warning IP 20 Air Cooled THD upto 37% As per rating No 0 minutes DC Choke Optional Yes No side and rear clearance required 965,000 for 650A 18 Months from Shipment Air Cooled THD current upto 35% As per rating Yes as Option 0 minutes DC Choke on both limbs Yes No Side and rear clearance required Not quoted 15 months from Shipment

Not received

Aircooled As per rating No 0 minutes DC Choke Yes No Side and rear clearance required 856,000 for 616A 18 Months from Shipment

Eaton

Vacon

A v a i l a b l e i n I n d i a u p t o 2 0 0 H p O n l y .

H a s n o t r e s p o n d e d t o m e e t i n g c a l l s